Loading...
HomeMy WebLinkAbout08200-02-0 - Wood Doors - Shop Drawings - reviewed by PBA - AN-SS MAGGIORE CONSTRUCTION CORP. 13 Wheeling Avenue, Woburn, MA 01801 Phone 781.935.6100 FAX 781.933.8044 SUBMITTAL ACTION SHEET Oxoboxo Lofts 40 Pink Row Uncasville, CT General Contractor:Architect: Maggiore Construction Corp. Paul B Bailey Architects 13 Wheeling Ave. 110 Audubon Street Woburn, MA 01801 New Haven, CT 06510 Job No.: 1529 Job No.: 16-063 Prepared By:Maggiore Construction Corp. Form of Submittal: Samples Cut Sheets Schedule Shop Drawings Other Description:Exterior door samples Samples of glass in Tricoya and MDO with Spacer bars & without Sapelle wood samples with wood muntin profile Tricoya product literature Tricoya sample Manufacturer:Jackson Lumber Other/Notes:Specification: None for exterior entry doors Gave to PPB on 2-6-20 at Owner/Arch. meeting Received By MCC:2/4/2020 Received By Owner: Reviewed:Comments: Approved Approved as Noted Rejected Revise and Re-submit Compliance Equal Submitted For Approval By: Gifford Perry - Senior Project Manager Approved By: Date:2/6/2020 Date: This review is only for general conformance with the design concept and the information given in the Construction Documents. Corrections or comments made of the shop drawings during this review do not relieve the contractor from compliance with the requirements of the Construction Documents. Review of a specific item shall not include review of an assembly of which the item is a component. The Contractor is responsible for: quantities; dimensions to be confirmed and correlated at the jobsite; information that pertains solely to the fabrication process or to the means, methods, techniques, sequences and procedures of construction; coordination of the Work of all other trades and for performing all work in a safe and satisfactory manner. Submittals that deviate in any way from the requirements of the documents must be so identified in the submittal by the Contractor. The Architect’s review of any submission that does not clearly identify said deviation(s) does not indicate approval of said deviation not identified. Reviewed Rejected Furnish as Corrected Revise & Resubmit Not Reviewed For Record Only Submit Specified Items Paul B. Bailey Architect, LLC Date: Reviewed By: x x Sam Kirby 3/23/20 Submit exterior wood door jambs, transoms and sidelights separately. VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO FABRICATION AND INSTALLATION.DOES THIS ACCOUNT FOR REMOVING EXISTING SILL?DIMENSIONSLOOKSUSPECT.DOES THISACCOUNT FORRAISED SILL?PROVIDE DIMENIONS.DIMENSIONSLOOK SLIGHTLYSUSPECT.NEW BRICK OPENING WITHNEW STEELLINTEL.MATCH DIMENSIONS OF NEW DOOR OPENING WITH EXISTING D-43-A DOOR.DOES THISACCOUNT FORRAISED SILL?DOESTHISACCOUNT FORRAISED SILL?INCLUDE AB CONNECTOR EGRESS DOOR D-60.INCLUDE BUILDING J ELECTRICAL ROOM DOOR D-63.DIMENSIONSLOOKSLIGHTLYSUSPECT.DIMENSIONSLOOKSLIGHTLYSUSPECT.RAISED GRANITE SILL.INCLUDE BUILDING L NORTH FACADE DOOR D-63.INCLUDE BUILDING B 'FAUX' DOORS AT NORTH FACADE UPPER LEVELS. SEE AASK092 AND ASK066R1.4-PANEL DOORS AT 'FAUX' DOORS AT BUILDING A WEST FACADE AND BUILDING B NORTH FACADE UPPER LEVELS.SUBMIT WOOD JAMBS, TRANSOMS AND SIDELIGHTS SEPARATELY.