HomeMy WebLinkAboutRFI 018 - Exterior Door schedule - answered by PBA - 191127Distribution to:
OWNER X
ARCHITECT X
ENGINEER
13 Wheeling Ave
Woburn, MA 01801781-935-6100
REQUEST FOR INFORMATION NO. 18
PROJECT:OXOBOXO LOFTS RFI #18
INITIATION DATE:10/24/19
FROM:Maggiore Construction Corporation DATE NEEDED:10/31/19
13 Wheeling Avenue
Woburn, MA 01801
REQUESTED BY:Gifford Perry
EMAIL: gifford@maggiorecos.com
TO:Paul B. Bailey Architect
110 Audubon Street
New Haven, CT 06510
ATTENTION:Susan Odell- email: susan@pbbarchitect.com
Frank Brachanow-Email Fbrachanow@dakotaPartners.net
Sam Kirby
SUBJECT:
REQUEST:Please proivde the following questions on exterior doors
How many units total door schedule has 24 wood units
Elevations have 26
Door # D60 no elevation but on schedule
Need a hardware schedule for all of these units
Egress hardware ?
Hardware Finish
Keying – access control or removeable cores
Hinge size and finish
Composite jambs ? or Qtr Sawn Sapele
Doors are qtr sawn saplele
Glass is tempered IG or LoE
Grill are applied or GIA
Width of grill – color if GIA – profile if SDL or SDL with bronze spacer ?
Doors are 1 ¾” Sapele
In swing or out swing
Sticking
Panel flat or raised
Are doors painted or stain grade
If painted do you want primed or one coat of finish ?
Sill – standard or ADA
Transoms
Are these true sash glazed or Tricoya sash
Answered By:
Company: Date:
Exterior door schedule
See attached Door
Hardware Schedule
See plans.
Ovolo profile.
Door glazing:
Simulated Divided Lights:
5/8" adhered interior painted wood grills.
5/8" spacer.
5/8" adhered putty profile muntin.
See revised exterior door
elevations sheet attached.
Sam Kirby
Paul Bailey Architect 11/27/19
Shop primed and finished
coat. See paint specifications.
D60 is flush metal.
(See attached revised door schedule.)
Exterior Wood and Glass = 26
Exterior Insulated Metal = 5
Total Exterior Doors = 31
(See attached revised door schedule.)
INTERIOR DOOR ELEVATIONSSTYLE ASEE SCHEDULESEE SCHEDULESEE SCHEDULESEE SCHEDULESTYLE FSEE SCHEDULESEE SCHEDULEEQ EQSEE SCHEDULESEE SCHEDULESTYLE CSTYLE BSEE SCHEDULESEE SCHEDULESEE SCHEDULESEE SCHEDULESEE SCHEDULESEE SCHEDULESEE SCHEDULESEE SCHEDULESEE SCHEDULESEE SCHEDULESEE SCHEDULESEE SCHEDULESEE SCHEDULEEQ EQSEE SCHEDULESEE SCHEDULESEE SCHEDULESEE SCHEDULESEE SCHEDULESTYLE DSTYLE ECLEAR GLASSWIRE GLASS(100 SI MAX)STYLE GSEE SCHEDULESEE SCHEDULESEE SCHEDULESEE SCHEDULESTYLE HScaleDateDrawn ByChecked ByProject NumberUNCASVILLE, CT42 PINK ROW1/4" = 1'-0"A5-10r1DOORSCHEDULEDakotaPartners, Inc.OXOBOXOLOFTSCheckerAuthor10/12/201816-063Door ScheduleMark Style Location DescriptionSingle/PairWidth Height Fire Rating Frame Type DoorJamb Detail Door Head DetailHardwareSetCommentsExterior DoorsD-37 D-37 BUILDING A - LEVEL 1 Wood Panel with Glass and Sidelight(s) and Transom Single 6' - 0" 8' - 6" Not Rated Wood 02D-38 D-38 BUILDING A - LEVEL 2 Wood Panel with Glass and Sidelight(s) Single 4' - 2" 8' - 3" Not Rated Wood 02D-39 D-39 BUILDING B - FRONT DOOR Wood and Glass Single 4' - 10" 7' - 4" Not Rated Wood 02D-40 D-40 BUILDING B - STAIR Wood Panel with Glass Single 3' - 4" 7' - 2" Not Rated Wood 02D-41 D-41 BUILDING B - MECHANICAL ENTRY Wood Panel with Glass and Sidelight(s) and Transom Single 5' - 0" 8' - 0" Not Rated Wood 02D-42 D-42 BUILDING B - BASEMENT ENTRY Wood Panel with Glass and Sidelight(s) Single 4' - 8" 6' - 11" Not Rated Wood 02D-43A D-43 BUILDING C - UNIT C1 ENTRY Wood Panel with Transom Single 3' - 8" 9' - 2" Not Rated Wood 15D-43B D-43 BUILDING C - UNIT C2 ENTRY Wood Panel with Transom Single 3' - 8" 9' - 2" Not Rated Wood 15D-44 D-44 BUILDING C - UNIT ENTRY Wood Panel with Transom Single 3' - 7" 7' - 11" Not Rated Wood 15D-45 D-45 BUILDING C - UNIT ENTRY Wood Panel with Sidelight(s) Single 5' - 0" 7' - 11" Not Rated Wood 15D-46 D-46 BUILDING D - UNIT ENTRY Wood Panel with Sidelight(s) and Transom Single 4' - 4" 8' - 2" Not Rated Wood 15D-47 D-47 BUILDING D - STAIR Wood Panel with Transom Single 3' - 8" 9' - 2" Not Rated Wood 02D-48 D-48 BUILDING D - UNIT ENTRY Wood Panel with Sidelight(s) and Transom Single 4' - 11" 8' - 3" Not Rated Wood 15D-49 D-49 BUILDING E - COMMUNITY ROOM ENTRY Wood Panel with Glass and Sidelight(s) Single 5' - 11" 8' - 3" Not Rated Wood 02D-50 D-50 BUILDING E - OFFICE ENTRY Wood and Glass with Sidelight(s) Double 8' - 9" 7' - 8" Not Rated Wood 01D-51A D-51 BUILDING E - STAIR Wood Panel with Glass with Transom Single 3' - 8" 9' - 2" Not Rated Wood 02D-51B D-51 BUILDING E - FIRST FLOOR CORRIDOR Wood Panel with Glass with Transom Single 3' - 8" 9' - 2" Not Rated Wood 02D-53 D-53 BUILDING F - EAST Wood Panel with Glass and Sidelight(s) and Transom Double 8' - 8" 8' - 8" Not Rated Wood 01D-54 D-54 BUILDING F - WEST Wood Panel with Glass Single 3' - 0" 6' - 6" Not Rated Wood 02D-55 D-55 BUILDING G - REAR EXIT Wood Panel with Glass and Sidelight(s) and Transom Single 7' - 2" 8' - 9" Not Rated Wood 02D-56 D-56 BUILDING H - NORTH Wood Panel with Glass with Transom Double 7' - 2" 11' - 3" Not Rated Wood 01D-57 D-57 BUILDING J - REAR EXIT Wood Panel with Glass and Sidelight(s) and Transom Single 7' - 2" 11' - 3" Not Rated Wood 02D-58 D-58 BUILDING L - SOUTH Wood Panel with Glass Double 7' - 0" 8' - 1" Not Rated Wood 01D-59A D-59 BUILDING M - FRONT ENTRY Wood Panel with Glass with Transom Double 7' - 2" 10' - 0" Not Rated Wood 01D-59B D-59 BUILDING M - REAR ENTRY Wood Panel with Glass with Transom Double 7' - 2" 10' - 0" Not Rated Wood 01D-60 FL-1 BUILDING AB - REAR STAIR EXIT Flush Metal - insulated Single 3' - 0" 6' - 8" Not Rated Hollow Metal 02D-61 FL-2 BUILDING A - CRAWL SPACE ACCESS Flush Metal - insulated Double 4' - 0" 6' - 8" Not Rated Hollow Metal 16D-62 FL-1 BUILDING D - ELECTRICAL ROOM Flush Metal - insulated Single 3' - 0" 6' - 8" Not Rated Hollow Metal 02D-63 D-63 BUILDING H - ELECTRICAL ROOM Wood Panel with Glass and Sidelight(s) and Transom Single 7' - 2" 8' - 9" Not Rated Wood 02D-64 FL-2 BUILDING M - BASEMENT ENTRY FROM COURTYARD Flush Metal - insulated Double 7' - 0" 6' - 8" Not Rated Hollow Metal 16D-65 FL-2 BUILDING M - BASEMENT ENTRY EAST Flush Metal - insulated Double 7' - 0" 6' - 8" Not Rated Hollow Metal 16Interior DoorsD-7 F EXIT STAIR Flush Metal with Glass Single 3' - 0" 6' - 8" 90 MIN. Hollow Metal 5/A5-8 6/A5-8 10D-8 G JANITOR ROOM Flush Metal Single 3' - 0" 6' - 8" 20 MIN. Hollow Metal 1/A5-8 2/A5-8 06D-9 G JANITOR ROOM Flush Metal Single 3' - 0" 6' - 8" 20 MIN. Hollow Metal 1/A5-8 2/A5-8 07D-9A G MECHANICAL ROOM Flush Metal Single 2' - 6"6' - 8" 20 MIN. Hollow Metal 1/A5-8 2/A5-8 07D-9B G MECHANICAL ROOM Flush Metal Single 3' - 0"6' - 8" 20 MIN. Hollow Metal 1/A5-8 2/A5-8 07D-9E G MECHANICAL ROOM Flush Metal Single 3' - 0"6' - 8" 20 MIN. Hollow Metal 1/A5-8 2/A5-8 07D-10 A PUBLIC TOILET Molded 4 Panel Single 3' - 0" 6' - 8" 20 MIN. Wood 3/A5-8 4/A5-8 04D-11 A OFFICE Molded 4 Panel Single 3' - 0" 6' - 8" Not Rated Wood 3/A5-8 4/A5-8 03D-12 A LEASING OFFICE Molded 4 Panel Single 3' - 0" 6' - 8" 20 MIN. Wood 3/A5-8 4/A5-8 06D-13 A FILE CLOSET Molded 4 Panel Single 2' - 6" 6' - 8" Not Rated Wood 3/A5-8 4/A5-8 05D-14 G MECHANICAL ROOM Flush Metal Single 3' - 0"6' - 8" 20 MIN. Hollow Metal 1/A5-8 2/A5-8 08D-26 H IDF ROOM Flush Metal Double 4' - 0" 6' - 8" 20 MIN. Hollow Metal 5/A5-8 6/A5-8 09Unit DoorsD-1 A UNIT ENTRY Molded 4 Panel Single 3' - 0" 6' - 8" 20 MIN. Hollow Metal 1/A5-8 2/A5-8 11D-2 A BEDROOM/BATHROOM Molded 4 Panel Single 3' - 0" 6' - 8" Not Rated 3/A5-8 4/A5-8 12D-2A A BEDROOM/BATHROOM Molded 4 Panel Single 2' - 6" 6' - 8" Not Rated Wood 3/A5-8 4/A5-8 12D-2B E BEDROOM Wood and Glass Single 3' - 0" 6' - 8" Not Rated Wood 3/A5-8 4/A5-8 12D-2D A BEDROOM/BATHROOM Molded 4 Panel Single 3' - 0" 6' - 8" Not Rated Wood 3/A5-8 4/A5-8 -D-3 A COAT CLOSET Molded 4 Panel Single 2' - 6" 6' - 8" Not Rated Wood 3/A5-8 4/A5-8 13D-3A A COAT CLOSET Molded 4 Panel Single 2' - 6" 6' - 8" Not Rated Wood 3/A5-8 4/A5-8 14D-3B D COAT CLOSET Molded 2 Panel Double 3' - 6" 6' - 8" Not Rated Wood 3/A5-8 4/A5-8 14D-3C D COAT CLOSET Molded 2 Panel Double 3' - 6" 6' - 8" Not Rated Wood 3/A5-8 4/A5-8 14D-3D A COAT CLOSET Molded 4 Panel Single 2' - 0" 6' - 8" Not Rated Wood 3/A5-8 4/A5-8 13D-4 C BEDROOM CLOSET Molded 4 Panel Double 5' - 0" 6' - 8" Not Rated Wood 3/A5-8 4/A5-8 14D-4A A BEDROOM CLOSET Molded 4 Panel Single 2' - 6" 6' - 8" Not Rated Wood 3/A5-8 4/A5-8 13D-4B D BEDROOM CLOSET Molded 2 Panel Double 4' - 0" 6' - 8" Not Rated Wood 3/A5-8 4/A5-8 14D-4C D BEDROOM CLOSET Molded 4 Panel Double 3' - 6" 6' - 8" Not Rated Wood 3/A5-8 4/A5-8 14D-4D B LINEN CLOSET Molded 2 Panel Single 2' - 0" 6' - 8" Not Rated Wood 3/A5-8 4/A5-8 13D-5 B LINEN CLOSET Molded 2 Panel Single 1' - 4" 6' - 8" Not Rated Wood 3/A5-8 4/A5-8 13D-5A B LINEN CLOSET Molded 2 Panel Single 1' - 6" 6' - 8" Not Rated Wood 3/A5-8 4/A5-8 13D-5B B LINEN CLOSET Molded 2 Panel Single 2' - 0" 6' - 8" Not Rated Wood 3/A5-8 4/A5-8 13D-5D A LINEN CLOSET Molded 4 Panel Single 2' - 6" 6' - 8" Not Rated Wood 3/A5-8 4/A5-8 13No. Description Date1 Addendum 01 2/1/192 Addendum 02 2/25/193 Permit Set 2/26/194 Addendum 03 4/12/195 Addendum 04 4/23/19
EXTERIOR DOOR TYPE12' - 1"7" 3' - 0" 3' - 0" 7"12' - 1"2' - 1" 3' - 0" 2' - 1"7' - 2"7' - 2"6" 3' - 0" 3' - 0" 6"7' - 0"9' - 1"TYPE D-377' - 0" 3' - 10" 1' - 3"7' - 0" 3' - 10" 1' - 3"7' - 0"1' - 1" 1' - 0"7' - 0" 1' - 6"8' - 6"1' - 6" 3' - 0" 1' - 6"6' - 0"BUILDING A (1)QUANTITY: 1CORRIDOR TO UNITS A1, A2, A3BUILDING A (2)QUANTITY: 1CORRIDOR TO UNITS A4, A5, A6TYPE D-387' - 0"6"1' - 1 1/4" 3' - 6 1/2" 1' - 1 1/4"3' - 6 1/2"BUILDING B (1)QUANTITY: 1MAIN ENTRY TO BUILDING BTYPE D-3911" 3' - 0" 11"4' - 10"7' - 0"4"7' - 4"BUILDING B (2)QUANTITY: 1EXIT FROM EGRESS STAIRTYPE D-402"7' - 0"7' - 2"3' - 4"2"3' - 0"2"BUILDING B (3)QUANTITY: 1ENTRANCE TO MECHANICAL ROOMSTYPE D-411' - 0"8' - 0"1' - 0"3' - 0"1' - 0"5' - 0"BUILDING B (4)QUANTITY: 1CORRIDOR TO UNITS B1, B2TYPE D-423"6' - 8"1' - 4 3/4" 3' - 0"3 1/4"4' - 8"6' - 11"BUILDING C (1)QUANTITY: 2ENTRANCE TO UNIT C1ENTRANCE TO UNIT C2TYPE D-437' - 0" 2' - 4"9' - 4"4"3' - 0" 4"3' - 8"BUILDING C (2)QUANTITY: 1ENTRANCE TO UNIT C3TYPE D-447' - 0" 1' - 1 1/8"8' - 1 1/8"3 1/2"3' - 0" 3 1/2"3' - 7"BUILDING C (3)QUANTITY: 1ENTRANCE TO UNIT C4TYPE D-457' - 0" 11"7' - 11"1' - 0" 3' - 0" 1' - 0"5' - 0"TYPE D-46BUILDING D (1)QUANTITY: 1ENTRANCE TO UNIT D27' - 0" 1' - 5"8' - 5"3 1/2" 3' - 0"1' - 0 1/2"4' - 4"TYPE D-47BUILDING D (2)QUANTITY: 1STAIR TO UNITS D3, D42' - 4"9' - 4"4" 3' - 0" 4"3' - 8"BUILDING D (3)QUANTITY: 1ENTRANCE TO UNIT D11' - 6 7/8"7' - 0"8' - 6 7/8"TYPE D-4811 1/2" 3' - 0" 11 1/2"4' - 11"BUILDING E (1)QUANTITY: 1ENTRANCE TO FITNESS ROOMTYPE D-497' - 0"11 5/8"7' - 11 5/8"1' - 5 1/2" 3' - 0" 1' - 5 1/2"5' - 11"BUILDING E (2)QUANTITY: 1ENTRANCE TO LEASING OFFICETYPE D-508"7' - 8"1' - 9 1/2" 6' - 0" 1' - 9 1/2"9' - 7"BUILDING E (3)QUANTITY: 2ENTRANCE TO UNITS E2, E3BACK ENTRANCE TO OFFICE AND FITNESS ROOMTYPE D-512' - 4"7' - 0"9' - 4"4"3' - 0"4"3' - 8"BUILDING F (1)QUANTITY: 1ENTRANCE TO ELEVATOR LOBBYTYPE D-52BUILDING F (2)QUANTITY: 1ENTRANCE TO FITNESS/COMMUNITY ROOM7' - 0" 1' - 8"8' - 8"1' - 4" 6' - 0" 1' - 4"8' - 8"TYPE D-53BUILDING F (3)QUANTITY: 1BACK ENTRANCE TO FITNESS/COMMUNITY ROOMTYPE D-545"6' - 9"2"2' - 8"2"3' - 0"BUILDING G (1)QUANTITY: 1ENTRANCE TO CORRIDOR TO UNITS G1-G9TYPE D-557' - 0" 1' - 9" 10"9' - 7"2' - 1" 3' - 0" 2' - 1"7' - 2"BUILDING H (1)QUANTITY: 1LOBBY ENTRANCE AT BUILDING HTYPE D-56BUILDING J (1)QUANTITY: 1ENTRANCE TO CORRIDOR TO UNITS J1-J8TYPE D-57BUILDING L (1)QUANTITY: 1ENTRANCE TO MAINENANCE OFFICETYPE D-58BUILDING M (1)QUANTITY: 2EAST ENTRANCE TO CORRIDOR TO UNITS M1-M11WEST ENTRANCE TO CORRIDOR TO UNITS M1-M11TYPE D-597' - 0" 3' - 0" 11 1/8"10' - 11 1/8"7" 3' - 0" 3' - 0" 7"7' - 2"OMITTEDFLLUSH METAL INSULATED EXTERIOR SINGLE DOORTYPE FL-1FLUSH METAL INSULATTED EXTERIOR DOUBLE DOORTYPE FL-2GLAZED PANELOPAQUE PANELScaleDateDrawn ByChecked ByProject NumberUNCASVILLE, CT42 PINK ROWAs indicatedA5-11r1DOORELEVATIONS -EXTERIORDakotaPartners, Inc.OXOBOXOLOFTSCheckerAuthor10/12/201816-063No. Description Date4 Addendum 03 4/12/19
SECTION 08710 FINISH HARDWARE
OXOBOXO LOFTS SECTION 08710 - PAGE 1 of 19
SECTION 08710 - FINISH HARDWARE
PART 1 - GENERAL
A. RELATED DOCUMENTS
1. Drawings and general provisions of the Contract, including General and Supplementary
Conditions and other Division 1 Specification Sections, apply to this Section.
2. The General Conditions state that the Contract Documents are complementary, and what is
required by one shall be as binding as if required by all. Where there is a conflict within the
Contract Documents the most expensive option shall prevail.
1.1 SUMMARY
A. Section Includes
1. Furnishing and installation of all mechanical and electrical finish hardware necessary for all
doors, and hardware as specified herein and as enumerated in hardware sets and as indicated
and required by actual conditions at the building. The hardware shall include the furnishing
of all necessary screws, bolts, expansion shields, drop plates, and all other devices necessary
for the proper application of the hardware.
B. Related Sections
1. Division 6 Section – “Finish Carpentry”
2. Division 8 Section – “Interior and Exterior Doors”
3. Division 16 Section - Electrical
C. Specific Omissions: Hardware for the following is specified or indicated elsewhere, unless
specifically listed in the hardware sets:
1. Windows
2. Cabinets of all kinds, including open wall shelving and locks.
3. Signage, except as noted.
4. Complete toilet accessories including coat hooks, unless note otherwise.
1.2 REFERENCES
A. Applicable state and local building codes and standards.
B. FIRE/LIFE SAFETY
1. NFPA - National Fire Protection Association
a. NFPA 70 – National Electric Code
b. NFPA 80 - Standard for Fire Doors and Fire Windows
SECTION 08710 FINISH HARDWARE
OXOBOXO LOFTS SECTION 08710 - PAGE 2 of 19
c. NFPA 105 - Smoke and Draft Control Door Assemblies
2. State Fire Safety Code and Amendments to CT Supplement
C. UL - Underwriters Laboratories
1. UL 10B - Fire Test of Door Assemblies
2. UL 10C - Positive Pressure Test of Fire Door Assemblies
3. UL 1784 - Air Leakage Tests of Door Assemblies
4. UL 305 - Panic Hardware
D. Accessibility
1. ADA - Americans with Disabilities Act
2. ICC (CABO) / ANSI A117.1 - Accessible and Usable Buildings and Facilities
E. DHI - Door and Hardware Institute
1. Sequence and Format for the Hardware Schedule
2. Recommended Locations for Builders Hardware
F. ANSI - American National Standards Institute
1. ANSI/BHMA A156.1 - A156.29, and ANSI A156.31 - Standards for Hardware and
Specialties
1.3 SUBMITTALS
A. General: Submit the following in accordance with Conditions of Contract and Division 1
requirements. Advise architect within the submittal package of incompatibility or issues.
B. Catalog Cuts: Product data including manufacturers' technical product data for each item of door
hardware, installation instructions, maintenance of operating parts and finish, and other
information necessary to show compliance with requirements.
C. Final Hardware Schedule Content: Submit schedule with hardware sets in vertical format as
illustrated by the Sequence of Format for the Hardware Schedule as published by the Door and
Hardware Institute. Indicate complete designations of each item required for each door or opening,
Include the following information:
1. Door Index; include door number, heading number, and Architects hardware set number.
2. Opening Lock Function Spreadsheet; list locking device and function for each opening.
3. Type, style, function, size, and finish of each hardware item.
4. Name and manufacturer of each item.
5. Fastenings and other pertinent information.
6. Location of each hardware set cross-referenced to indications on Drawings.
7. Explanation of all abbreviations, symbols, and codes contained in schedule.
8. Mounting locations for hardware.
9. Door and frame sizes and materials.
10. Name and phone number for the local manufacturer's representative for each product.
SECTION 08710 FINISH HARDWARE
OXOBOXO LOFTS SECTION 08710 - PAGE 3 of 19
11. Operational Description of openings with any electrified hardware (locks, exits,
electromagnetic locks, electric strikes, automatic operators, door position switches, magnetic
holders or closer/holder units, and/or access control components). Operational description
should include how the door will operate on egress, ingress, and/or fire/smoke alarm
connection.
D. Key Schedule: After a keying meeting between representatives of the Owner, Architect, hardware
supplier, and, if requested, the representative for the lock manufacturer, provide a keying schedule,
listing the levels of keying, as well as an explanation of the key system's function, the key symbols
used, and the door numbers controlled. Utilize ANSI A156.28 “Recommended Practices for
Keying Systems” as a guideline for nomenclature, definitions, and approach for selecting the
optimal keying system.
E. Samples: If requested by the Architect, submit production sample or sample installations as
requested of each type of exposed hardware unit in the finish indicated, and tagged with a full
description for coordination with the schedule.
1. Samples will be returned to the supplier in like-new condition. Units that are acceptable to
the Architect may, after final check of operations, be incorporated into the Work, within
limitations of key coordination requirements.
F. Templates: After final approval of the hardware schedule, provide templates for doors, frames,
and other work specified to be factory prepared for the installation of door hardware.
G. Riser and Wiring Diagrams: After final approval of the hardware schedule, submit riser and wiring
diagrams as required for the proper installation of complete electrical, electromechanical, and
electromagnetic products.
H. Operations and Maintenance Data: Provide in accordance with Division 1 and include the
following:
1. Complete information on care, maintenance, and adjustment; data on repair and replacement
parts, and information on preservation of finishes.
2. Catalog pages for each product.
3. Name, address, and phone number of local representative for each manufacturer.
4. Parts list for each product.
5. Copy of final approved hardware schedule, edited to reflect “As installed.”
6. Copy of final keying schedule.
7. As installed “Wiring Diagrams” for each opening connected to power, both low voltage and
110 volts.
8. One (1) complete set of special tools required for maintenance and adjustment of hardware,
including changing of cylinders.
9. Copy of warranties including appropriate reference numbers for manufacturers to identify the
project.
I. Certificates of Compliance: Upon request of Architect or Authority Having Jurisdiction
certificates of compliance for fire-rated hardware and installation instructions shall be made
available.
1.4 QUALITY ASSURANCE
SECTION 08710 FINISH HARDWARE
OXOBOXO LOFTS SECTION 08710 - PAGE 4 of 19
A. Substitutions: Products are to be those specified to ensure a uniform basis of acceptable materials.
Requests for substitutions must be made in accordance with Division 1 requirements. If proposing
a substitute product, submit product data for the proposed item with product data for the specified
item and indicate basis for substitution and savings to be made. Provide sample if requested.
Certain products have been selected for their unique characteristics and particular project
suitability.
1. Items specified as "no substitute” shall be provided exactly as listed.
2. Items listed with no substitute manufacturers listed have been requested by the Owner or
Architect to match existing for continuity and/or future performance and maintenance
standards or because there is no known equal product.
3. If no other products are listed in a category, then "no substitute" is implied.
B. Supplier Qualifications: A recognized architectural hardware supplier, with warehousing facilities
in the Project's vicinity, that has a record of successful in-service performance for supplying door
hardware similar in quantity, type, and quality to that indicated for this Project and that provides
a certified Architectural Hardware Consultant (AHC) available to the Owner, Architect, and
Contractor, at reasonable times during the course of the Work for consultation.
C. Single Source Responsibility: Obtain each type of hardware (latch and locksets, hinges, exit
devices, closers, etc.) from a single manufacturer.
D. Fire-Rated Openings: Provide door hardware for fire-rated openings that complies with NFPA
Standard No. 80 and requirements of authorities having jurisdiction. Provide only items of door
hardware that are listed and are identical to products tested by Underwrites Laboratories, Intertek
Testing Services, or other testing and inspecting organizations acceptable to the authorities having
jurisdiction for use on types and sizes of doors indicated in compliance with requirements of fire-
rated door and door frame labels.
E. Electronic Security Hardware: When electrified hardware is included in the hardware
specification, the hardware supplier must employ an individual knowledgeable in electrified
components and systems, who is capable of producing wiring diagrams and consulting as needed.
Coordinate installation of the electronic security hardware with the Architect and Electrical
Engineer and provide installation and technical data to the Architect and other related
subcontractors. Upon completion of electronic security hardware installation, inspect and verify
that all components are working properly.
1.5 DELIVERY, STORAGE, AND HANDLING
A. Tag each item or package separately with identification related to the final hardware schedule, and
include installation instructions with each item or package.
B. Each article of hardware shall be individually packaged in manufacturer's original packaging.
C. Contractor will provide secure lock-up for door hardware delivered to the Project, but not yet
installed. Control handling and installation of hardware items so that completion of Work will not
be delayed by hardware losses both before and after installation.
D. Items damaged in shipment shall be replaced promptly and with proper material and paid for by
whomever did the damage or caused the damage to occur.
SECTION 08710 FINISH HARDWARE
OXOBOXO LOFTS SECTION 08710 - PAGE 5 of 19
E. Hardware shall be handled in a manner to avoid damage, marring, or scratching. Irregularities that
occur to the hardware after it has been delivered to the Project shall be corrected, replaced, or
repaired by the Contractor. Hardware shall be protected against malfunction due to paint, solvent,
cleanser, or any chemical agent.
F. No direct shipments will be allowed unless approved by the Contractor.
1.6 WARRANTY
A. Provide manufacturer's warrantees as specified in Division 1 and as follows:
1. Closers: 10 years, except electronic closers, 2 years.
2. Exit Devices: 3 years.
3. Locksets: 3 years, except electrified locksets, 1 year.
4. Other hardware: 1 year.
B. No liability is to be assumed where damage or faulty operation is due to improper installation,
improper use, or abuse.
C. Products judged to be defective during the warranty period shall be replaced or repaired in
accordance with the manufacturer's warranty, at no additional cost to the Owner.
1.7 MAINTENANCE
A. Maintenance Tools and Instructions: Furnish a complete set of specialized tools and maintenance
instructions as needed for Owner's continued adjustment, maintenance, and removal and
replacement of door hardware.
PART 2 - PRODUCTS
2.1 MANUFACTURERS
A. Approval of manufacturers other than those listed shall be in accordance with paragraph 1.05.A.
B. Note that even though an acceptable substitute manufacturer may be listed, the product must
provide all the functions and features of the specified product or it will not be approved.
Item Scheduled Manufacturer Acceptable Substitute
Hinges Stanley, Hager Ives
Flush Bolts Rockwood Burns, Ives
Locksets & Deadlocks Schlage (SCH)
Exit Devices & Mullions Monarch Von Duprin
Door Closers Dorma LCN
HC Door Operator Dorma, LCN
Door Trim Ives (IVE) Burns, Rockwood
Protection Plates Rockwood Burns, Ives
Overhead Stops Glynn-Johnson (GLY) Rixson, Sargent
Stops & Holders Hager, Rockwood Burns
Thresholds & Weatherstrip Hager, Ives, Rockwood Pemko, Zero, National
Guard
Silencers Ives (IVE) Burns, Rockwood
SECTION 08710 FINISH HARDWARE
OXOBOXO LOFTS SECTION 08710 - PAGE 6 of 19
Magnetic Holders LCN Rixson, Dorma, Sargent
Door Viewer Ives (IVE) Burns, Rockwood
Bi-Pass Hardware Door Mfgr Standard
Cylinders & Keying Schlage (SCH)
Latch Protector Don-Jo
Key Cabinets Telkee (TEL) HPC, Lund
Key Management Software Schlage (SCH)
C. Hand of Door: Drawings show direction of slide, swing, or hand of each door leaf. Furnish each
item of hardware for proper installation and operation of door movement as shown.
D. Where the hardware specified is not adaptable to the finished shape or size of the members
requiring hardware, furnish suitable types having the same operation and quality as the type
specified, subject to the Architect's approval.
2.2 MATERIALS
A. Fasteners
1. Provide hardware manufactured to conform to published templates, generally prepared for
machine screw installation.
2. Furnish screws for installation with each hardware item. Finish exposed (exposed under any
condition) screws to match hardware finish, or, if exposed in surfaces of other work, to match
finish of this other work as closely as possible including "prepared for paint" surfaces to
receive painted finish.
3. Provide concealed fasteners for hardware units that are exposed when door is closed except
to the extent that no standard units of type specified are available with concealed fasteners.
Do not use thru-bolts for installation where bolt head or nut on opposite face is exposed in
other work unless their use is the only means of reinforcing the work adequately to fasten the
hardware securely. Review door specification and advise Architect if thru-bolts are required.
4. Hardware shall be installed with the fasteners provided by the hardware manufacturer.
B. Hinges
1. Provide five-knuckle, ball bearing hinges of type, material, and height as outlined in the
following guide for this specification:
a. 1-3/4 inch thick doors, up to and including 36 inches wide:
Exterior: standard weight, bronze/stainless steel, 4-1/2 inches high
Interior: standard weight, steel, 4-1/2 inches high
b. 1-3/4 inch thick doors over 36 inches wide:
Exterior: heavy weight, bronze/stainless steel, 5 inches high
Interior: heavy weight, steel, 5 inches high
c. 2 inches or thicker doors:
Exterior: heavy weight, bronze/stainless steel, 5 inches high
Interior: heavy weight, steel, 5 inches high
2. Provide three hinges per door leaf for doors 90 inches or less in height, and one additional
hinge for each 30 inches of additional door height.
3. Hinge Pins: Except as otherwise indicated, provide hinge pins as follows:
SECTION 08710 FINISH HARDWARE
OXOBOXO LOFTS SECTION 08710 - PAGE 7 of 19
a. Steel Hinges: Steel pins
b. Non-Ferrous Hinges: Stainless steel pins
c. Out-Swinging Exterior Doors: Non-removable pins
d. Out-Swinging Interior Lockable Doors: Non-removable pins
e. Interior Non-lockable Doors: Non-rising pins
4. The width of hinges shall be 4-1/2 inches at 1-3/4 inch thick doors, and 5 inches at 2 inches
or thicker doors. Adjust hinge width as required for door, frame, and/or wall conditions to
allow proper degree of opening.
5. Acceptable manufacturers and/or products: Stanley, Ives 5BB series, Hager BB series.
C. Flush Bolts
1. Provide automatic and manual flush bolts with forged bronze face plates, extruded brass
levers, and with wrought brass guides and strikes. Provide 12 inch steel or brass rods at doors
up to 90 inches in height. Top rods at manual flush bolts for doors over 90 inches in height
shall be increased by 6 inches for each additional 6 inches of door height. Provide dust-proof
strikes at each bottom flush bolt.
2. Acceptable manufacturers and/or products: Rockwood, Ives, Burns.
D. Cylindrical Locks - Grade 1
1. Provide cylindrical locks conforming to ANSI A156.2 Series 4000, Grade 1. Cylinders: Refer
to 2.04 KEYING.
2. Provide locks with a standard 2-3/4 inches backset, unless noted otherwise, with a 1/2 inch
latch throw. Provide proper latch throw for UL listing at pairs.
3. Provide locksets with a separate anti-rotation throughbolts, and shall have no exposed screws.
Levers shall operate independently, and shall have two external return spring cassettes
mounted under roses to prevent lever sag.
4. Provide standard ASA strikes unless extended lip strikes are necessary to protect trim.
5. Provide electrical options as scheduled.
6. Lever trim shall be solid cast levers without plastic inserts, and wrought roses on both sides.
Locksets shall be thru-bolted to assure proper alignment.
a. Lever design shall be Schlage Avila
b. Lever trim on the secure side of doors serving rooms considered by the authority having
jurisdiction to be hazardous shall have a tactile warning.
7. Acceptable manufacturers and/or products: Schlage ND series.
E. Tubular Locks - Grade 2
1. Provide tubular locks conforming to ANSI A156.2 Series 4000, Grade 2. Cylinders: Refer
to 2.04 KEYING.
2. Provide locks with a standard 2-3/8 inches adjustable to 2-3/4 inches backset with a 1/2 inch
latch throw. Provide 2 3/4” backset, unless 2-3/8 inches is required by door or frame detail,
or noted otherwise.
3. Provide locksets that fit a standard 2-1/8 inches diameter bore without the use of thru-bolts.
Standard rose size shall be 2-1/2 inches in diameter. Locksets shall be adjustable to fit in 1-
3/8 inches or 1-3/4 inches door thickness.
4. Provide standard T-strikes unless extended lip strikes are necessary to protect trim.
SECTION 08710 FINISH HARDWARE
OXOBOXO LOFTS SECTION 08710 - PAGE 8 of 19
5. Lever trim shall be solid cast levers without plastic inserts, and wrought roses on both sides.
a. Lever design shall be Schlage Avila.
6. Acceptable manufacturers and/or products: Schlage F series.
F. Exit Devices
1. Provide exit devices tested to ANSI/BHMA A156.3 Grade 1, and UL listed for Panic Exit
and/or Fire Exit Hardware. Cylinders: Refer to 2.04 KEYING.
2. Exit devices shall be touchpad type, fabricated of brass, bronze, stainless steel, or aluminum,
plated to the standard architectural finishes to match the balance of the door hardware.
3. Touchpad shall extend a minimum of one half of the door width. Touch-pad finish shall be
compatible to exit device finish. Compression springs will be used in devices, latches, and
outside trims or controls, tension springs also acceptable.
4. Devices to incorporate a deadlatching feature for security and/or for future addition of alarm
kits and/or other electrical requirements.
5. Provide manufacturer's standard strikes.
6. Provide exit devices cut to door width and height. Locate exit devices at a height
recommended by the exit device manufacturer, allowable by governing building codes, and
approved by the Architect.
7. Mechanism case shall sit flush on the face of all flush doors, or spacers shall be furnished to
fill gaps behind devices. Where glass trim or molding projects off the face of the door,
provide glass bead kits.
8. Removable mullions shall be a 2 inches x 3 inches steel tube. Where scheduled, mullion shall
be of a type that can be removed by use of a keyed cylinder, which is self-locking when re-
installed.
9. Where lever handles are specified as outside trim for exit devices, provide heavy-duty lever
trims with forged or cast escutcheon plates. Provide vandal-resistant levers that will travel to
a 90-degree down position when more than 35 pounds of torque are applied, and which can
easily be re-set.
a. Lever style will match the lever style of the locksets.
b. Lever trim on doors serving rooms considered by the authority having jurisdiction to be
hazardous shall have a tactile warning.
10. Exit devices for fire rated openings shall be UL labeled fire exit hardware.
11. Acceptable manufacturers and/or products: Monarch 19 series, Von Duprin AX series.
G. Door Closers
1. Provide door closers certified to ANSI/BHMA A156.4 Grade 1 requirements by a BHMA
certified independent testing laboratory. Closers shall be ISO 9000 certified. Units shall be
stamped with date of manufacture code.
2. Door closers shall have fully hydraulic, full rack and pinion action with an aluminum
cylinder. Closer body shall be 1-1/2 inch diameter, and heat-treated pinion journal shall be
11/16 inch diameter.
3. Provide hydraulic fluid requiring no seasonal closer adjustment for temperatures ranging
from 120 degrees F to 10 degrees F. Fluid shall be fireproof and shall pass the requirements
of the UL10C “positive pressure” fire test.
SECTION 08710 FINISH HARDWARE
OXOBOXO LOFTS SECTION 08710 - PAGE 9 of 19
4. Spring power shall be continuously adjustable over the full range of closer sizes, and allow
for reduced opening force as required by accessibility codes and standards. Hydraulic
regulation shall be by tamper-proof, non-critical valves. Closers shall have separate
adjustment for latch speed, general speed, and backcheck.
5. Provide special templates, drop plates, mounting brackets, or adapters for arms as required
for details, overhead stops, and other finish hardware items interfering with closer mounting.
6. Mount closers on room side of corridor doors, inside of exterior doors, and stair side of
stairway doors from corridors. Closers shall not be visible in corridors, lobbies and other
public spaces unless approved by Architect.
7. Door closers meeting this specification: Dorma 8600 series, LCN 8310 series.
H. Door Trim
1. Provide push plates 4 inches wide x 16 inches high x 0.050 inch thick and beveled 4 edges.
Where width of door stile prevents use of 4 inches wide plate, adjust width to fit.
2. Provide offset pulls of solid bar stock, diameter and length as scheduled. Where required,
mount back to back with push bar.
3. Provide pulls of solid bar stock, diameter and length as scheduled. Where required, mount
back to back with push bar.
4. Acceptable manufacturers and/or products: Rockwood, Ives, Burns.
I. Protection Plates
1. Provide kick plates, mop plates, and armor plates minimum of 0.050 inch thick as scheduled.
Furnish with machine or wood screws, finished to match plates. Sizes of plates shall be as
follows:
a. Kick Plates – 10 inches high x 2 inches less width of door on single doors, 1 inch less
width of door on pairs
2. Acceptable manufacturers and/or products: Rockwood, Ives, Burns.
J. Overhead Stops and Overhead Stop/Holders
1. Provide heavy or medium duty and concealed or surface mounted overhead stop or overhead
stop/holder for interior doors as specified. Provide medium duty surface mounted overhead
stop for interior doors and at any door that swings more than 140 degrees before striking a
wall, open against equipment, casework, sidelights, and/or where conditions do not allow a
wall stop or a floor stop presents a tripping hazard.
2. Where overhead holders are specified provide friction type at doors without a closer and
positive type at doors with a closer.
3. Acceptable manufacturers and/or products: Glynn-Johnson, Rixson, Sargent.
K. Door Stops and Holders
1. Provide door stops for all doors in accordance with the following requirements:
a. Provide wall stops wherever possible. Provide convex type where mortise type locks
are used and concave type where cylindrical type locks are used.
b. Where wall stops cannot be used, provide dome type floor stops of the proper height.
SECTION 08710 FINISH HARDWARE
OXOBOXO LOFTS SECTION 08710 - PAGE 10 of 19
c. At any opening where a wall or floor stop cannot be used, a medium duty surface
mounted overhead stop shall be used.
2. Acceptable manufacturers and/or products: Hager, Rockwood, Ives, Burns.
L. Thresholds, Seals, Door Sweeps, Automatic Door Bottoms, and Gasketing
1. Provide thresholds, weatherstripping (including door sweeps, seals, astragals) and gasketing
systems (including smoke, sound, and light) as specified and per architectural details. Match
finish of other items as closely as possible. Size of thresholds shall be as follows:
a. Saddle Thresholds – 1/2 inch high x jamb width x door width
2. Provide door sweeps, seals, astragals, and auto door bottoms only of type where resilient or
flexible seal strip is easily replaceable and readily available.
3. Acceptable manufacturers and/or products: Hager, Ives, Rockwood, National Guard, Pemko,
Zero.
M. Silencers
1. Provide "Push-in" type silencers for each hollow metal or wood frame. Provide three for each
single frame and two for each pair frame. Omit where gasketing is specified or required by
code.
2. Acceptable manufacturers and/or products: Ives, Burns, Rockwood.
N. Door Viewers
1. Provide appropriate door viewer for door type and rating with a minimum of 180-degree view
area.
2. Acceptable manufacturers and/or products: Ives, Burns, Rockwood.
O. Electro-Hydraulic Automatic Operators
1. Provide low energy automatic operator units with hydraulic closer complying with ANSI
A156.19 where automatic operators are specified.
2. Provide hydraulic fluid of a type requiring no seasonal closer adjustment for temperatures
ranging from 120 degrees F to -30 degrees F. Fluid shall be fireproof and shall pass the
requirements of the UL10C “positive pressure” fire test.
3. Provide units with conventional door closer opening and closing forces unless the power
operator motor is activated. Provide door closer assembly with adjustable spring size, back-check,
and opening and closing speed adjustment valves to control door
4. Provide units with on/off switch for manual operation, motor start up delay, vestibule
interface delay, electric lock delay, and door hold open delay.
5. Provide units with conventional door closer opening and closing forces unless the power
operator motor is activated. Provide door closer assembly with adjustable spring size, back-check
valve, sweep valve, latch valve to control door.
SECTION 08710 FINISH HARDWARE
OXOBOXO LOFTS SECTION 08710 - PAGE 11 of 19
6. Provide drop plates, brackets, or adapters for arms as required for details.
7. Provide hard-wired actuator switches for operation as specified. Actuators shall be
weather-resistant type at exterior applications.
8. Where automatic operators are scheduled, provide complete assemblies of controls,
switches, power supplies, relays, and parts/material recommended and approved by the
manufacturer of the automatic operator for each individual leaf. Actuators shall control both doors
simultaneously at pairs. Exterior and vestibule doors with automatic operators shall be sequenced
to allow ingress or egress through both sets of openings as directed by the Architect. Locate the
actuators, key switches, and other controls as directed by the Architect.
9. Provide units with vestibule inputs, which allow sequencing operation of two units, and a
SPDT relay for interfacing with latching or locking devices.
10. Acceptable manufacturers and/or products: LCN 4600 series, Dorma ED900 series.
P. Operating Trim, Latch Protector:
1. Acceptable manufacturers and/or products: Don-Jo ILP-212CP for unit entry doors.
Q. Magnetic Holders:
1. Acceptable manufacturers and/or products: Dorma EM series, LCN SEM7800 series, Sargent
1560 series, Rixson 990M series.
2.3 FINISHES
A. Finish of all hardware shall be US32D (BHMA 630) with the exceptions as follows:
1. Door Closers: Powder Coat to Match.
2. Weatherstripping: Clear Anodized Aluminum.
3. Thresholds: Mill Finish Aluminum.
4. All hardware at apartment units US26D (BHMA 626/652)
2.4 KEYING
A. Provide a new key system from the same manufacturer as the locks conforming to the following
requirements:
1. Provide removable core cylinders at all keyed devices. Provide construction cores with
construction master keying for use during construction. The hardware supplier, accompanied
by the Owner or Owner’s security agent, shall install permanent keyed cores upon completion
of the project. The temporary construction cores are to be returned to the hardware supplier.
2. Provide permanent cores and cylinders keyed by the manufacturer or authorized distributor
as directed by the Owner. Provide owner with a copy of the bitting list, return receipt
requested.
3. The hardware supplier, accompanied by a qualified factory representative for the
manufacturer of the cores and cylinders, shall meet with Owner and Architect to review
SECTION 08710 FINISH HARDWARE
OXOBOXO LOFTS SECTION 08710 - PAGE 12 of 19
keying requirements and lock functions prior to ordering finish hardware. Submit a keying
schedule to Architect for approval.
4. Provide cores and cylinders, unless noted otherwise, operated by a Grand Master Key System
to be established for this project (Do not use the letter "I", “O”, or “X” for any of the grand
masters). Allow for twenty-four Master Keys under each Grand Master, and sixty-four
changes under each master key. All cylinders shall be keyed in alike or different sets as noted
by their respective key set number. Do not use the letter "I" or “O” in any of the master key
sets.
5. Provide keys as follows
a. Ten grand master keys for each set.
b. Ten master keys for each set.
c. Three keys per core and/or cylinder.
d. Two construction core control keys
e. Two permanent core control keys
f. Six construction master keys for each type (Contractor is to provide one set of
construction keys to Architect)
6. Visual key control:
a. Keys shall be stamped with their respective key set number and stamped “DO NOT
DUPLICATE".
b. Grand master and master keys shall be stamped with their respective key set letters.
c. Do not stamp any keys with the factory key change number.
d. Do not stamp any cores with key set on face (front) of Core. Stamp on back or side of
cores so not to be visible when core is in cylinder.
7. Deliver grand master keys, master keys, change keys, and/or key blanks from the factory or
authorized distributor directly to the Owner in sealed containers, return receipt requested.
Failure to comply with these requirements may be cause to require replacement of all or any
part of the keying system that was compromised at no additional cost to the Owner.
8. Approved products: Schlage.
2.5 KEY CONTROL SYSTEM
A. Provide a key control system, including envelopes, labels, tags with self-locking key clips, receipt
forms, 3-way visible card index, temporary markers, permanent markers, and standard metal
cabinet, all as recommended by system manufacturer, with capacity for 150% of the number of
locks required for the Project.
1. Provide complete cross index system set up by the hardware supplier, and place keys on
markers and hooks in the cabinet as determined by the final key schedule.
2. Provide hinged-panel type cabinet for wall mounting.
3. Approved products: Telkee, HPC, Lund.
B. Key Management Software
1. Provide one stand-alone key management software package.
2. Software shall provide tracking, issuing, collecting and transferring information regarding
keys.
SECTION 08710 FINISH HARDWARE
OXOBOXO LOFTS SECTION 08710 - PAGE 13 of 19
3. Software shall provide customized query, reporting, searching capability, comprehensive
location hardware listings, display key holder photos and signature for verification, and
provide automatic reminders for maintenance, back-ups and overdue keys.
4. Provide training for Owner’s personnel on the proper operation and application of the key
management software.
5. Key management software meeting this specification: Schlage SiteMaster 200.
PART 3 - EXECUTION
3.1 EXAMINATION
A. Prior to installation of any hardware, examine all doors, frames, walls and related items for
conditions that would prevent proper installation of finish hardware. Correct all defects prior to
proceeding with installation.
3.2 INSTALLATION
A. Coordination:
1. Prior to installation of hardware, schedule and hold a meeting for the purpose of instructing
installers on proper installation and adjustment of finish hardware. Representatives of locks,
exit devices, closers, automatic operators, and electrified hardware shall conduct training;
provide at least 10 days notice to representatives. After training a letter of compliance,
indicating when the training was held and who was in attendance, shall be sent to the
Architect.
2. Prior to ordering electrified hardware, schedule and hold a meeting for the purpose of
coordinating finish hardware with security, electrical, doors and frames, and other related
suppliers. A representative of the supplier of finish hardware, and doors and frames, the
electrical subcontractor, and the Owner’s security contractor shall meet with the Owner,
Architect, and General Contractor prior to ordering finish hardware. After meeting a letter of
compliance, indicating when the training was held and who was in attendance, shall be sent
to the Architect.
B. Hardware will be installed by qualified tradesmen, skilled in the application of commercial grade
hardware. For technical assistance if necessary, installers may contact the manufacturer’s rep for
the item in question, as listed in the hardware schedule.
C. Mount hardware units at heights indicated in “Recommended Locations for Builders Hardware for
Standard Steel Doors and Frames” by the Door and Hardware Institute.
D. Install each hardware item in compliance with the manufacturer’s instructions and
recommendations, using only the fasteners provided by the manufacturer.
E. Do not install surface mounted items until finishes have been completed on the substrate. Protect
all installed hardware during painting.
F. Set units level, plumb and true to line and location. Adjust and reinforce the attachment substrate
as necessary for proper installation and operation.
G. Operating parts shall move freely and smoothly without binding, sticking, or excessive clearance.
SECTION 08710 FINISH HARDWARE
OXOBOXO LOFTS SECTION 08710 - PAGE 14 of 19
H. Wire (including low voltage), conduit, junction boxes, and pulling of wire is by Division 16,
Electrical. Electrical Contractor shall connect wire to door position switches and run wire to
central room or area as directed by the Architect. Wires shall be tested and labeled with the
Architects opening number. Connections to/from power supplies to electrified hardware and any
connection to fire/smoke alarm system, and/or smoke evacuation system where specified is by
Division 26 Electrical.
3.3 ADJUSTING, CLEANING, AND DEMONSTRATING
A. Adjust and check each operating item of hardware and each door, to insure proper operation or
function of every unit. Replace units which cannot be adjusted to operate freely and smoothly.
B. Where door hardware is installed more than one month prior to acceptance or occupancy of a space
or area, return to the installation during the week prior to acceptance or occupancy and make a
final check and adjustment of all hardware items in such space or area. Clean operating items as
necessary to restore proper function and finish of hardware and doors. Adjust door control devices
to compensate for final operation of heating and ventilating equipment.
C. Clean adjacent surfaces soiled by hardware installation.
D. Instruct Owner’s personnel in the proper adjustment, lubrication, and maintenance of door
hardware and hardware finishes.
3.4 FIELD QUALITY CONTROL
A. Prior to Substantial Completion, the installer, accompanied by representatives of the
manufacturers of locks, exit devices, closer, and any electrified hardware, shall perform the
following work:
1. Examine and re-adjust each item of door hardware as necessary to restore function of doors
and hardware to comply with specified requirements.
2. Consult with and instruct Owner’s personnel in recommended additions to the maintenance
procedures.
3. Replace hardware items that have deteriorated or failed due to faulty design, materials, or
installation of hardware units.
4. Prepare a written report of current and predictable problems of substantial nature in the
performance of the hardware.
5. At completion of project, a qualified factory representative for the manufacturers of locksets,
closer, exit devices, and access control products shall arrange and hold a training session to
instruct the Owner’s personnel on the proper maintenance, adjustment, and/or operation of
their respective products. After training a letter of compliance, indicating when the training
was held and who was in attendance, shall be sent to the Architect.
3.5 PROTECTION
A. Provide for the proper protection of complete items of hardware until the Owner accepts the project
as complete. Damaged or disfigured hardware shall be replaced or repaired by the responsible
party.
3.6 HARDWARE SCHEDULE
SECTION 08710 FINISH HARDWARE
OXOBOXO LOFTS SECTION 08710 - PAGE 15 of 19
A. Provide hardware for each door to comply with requirements of Section “Finish Hardware,”
hardware set numbers indicated in door schedule, and in the following schedule of hardware sets.
B. It is intended that the following schedule includes complete items of finish hardware necessary to
complete the work. If a discrepancy is found in the schedule, such as a missing item, improper
hardware for a frame, door or fire codes, the preamble will be the deciding document.
C. Locksets, exit devices, and other hardware items are referenced in the Hardware Sets for series,
type, and function. Refer to the preamble for special features, options, cylinders/keying, and other
requirements.
D. Hardware Style: Schlage; Avila Lever; Chrome.
E. Hardware Sets
HW SET: 01 (EXTERIOR PAIR)
6 EA HINGE 5BB1 4.5 X 4.5 NRP 630 IVE
1 EA PANIC DEVICE 25-R-DT 26D FAL
1 EA PANIC DEVICE 25-R-NL 26D FAL
2 EA VERTICAL ROD 9850 WDC-L 26D VD
2 EA SURFACE CLOSER SC71 RW/PA 689 FAL
2 EA MOUNTING PLATE SC70-18 689 FAL
2 EA OVERHEAD STOP 100S 630 GLY
2 EA KICK PLATE 8400 630 IVE
2 SETS SEALS 655C AL REE
2 EA SWEEP 354C AL REE
1 EA THRESHOLD S425A AL REE
DOOR CLOSER TO BE MOUNTED TOP-JAMB IN THE FLUSH CEILING POSITION (CLOSER
WILL REQUIRE DROP PLATE) TO PROVIDE CLEARANCE FOR THE OVERHEAD STOPS.
HW SET: 02 (EXTERIOR SINGLE)
3 EA HINGE 5BB1 4.5 X 4.5 652 IVE
1 EA ADA PULL 8103EZ-0 630 IVE
1 EA PANIC DEVICE 25-R-NL 626 IVE
1 EA MORTISE CYLINDER STOREROOM FUNCTION 626 SCH
1 EA SURFACE CLOSER SC71 RW/PA 689 FAL
1 EA MOUNTING PLATE SC70-18 689 FAL
1 EA KICK PLATE 8400 630 IVE
1 EA DOME STOP FS436 OR FS438 AS REQUIRED 626 IVE
1 SET SEAL DS69C AL REE
1 EA THRESHOLD S425A
AL REE
DOOR CLOSER TO BE MOUNTED TOP-JAMB IN THE FLUSH CEILING POSITION (CLOSER
WILL REQUIRE DROP PLATE) TO PROVIDE CLEARANCE FOR THE OVERHEAD STOPS.
SECTION 08710 FINISH HARDWARE
OXOBOXO LOFTS SECTION 08710 - PAGE 16 of 19
HW SET: 03 (OFFICE)
3 EA HINGE 5BB1 4.5 X 4.5 652 IVE
1 EA OFFICE LOCK ND50 626 SCH
1 EA DOME STOP FS436 OR FS438 AS REQUIRED 626 IVE
3 EA SILENCER SR64 GRY IVE
DOOR CLOSER TO BE MOUNTED TOP-JAMB IN THE FLUSH CEILING POSITION (CLOSER
WILL REQUIRE DROP PLATE) TO PROVIDE CLEARANCE FOR THE OVERHEAD STOPS.
HW SET: 04 (MEN & WOMEN)
3 EA HINGE 5BB1 4.5 X 4.5 652 IVE
1 EA PRIVACY SET ND40S 626 SCH
1 EA SURFACE CLOSER SC71 HD/PA 689 FAL
1 EA KICK PLATE 8400 630 IVE
3 EA SILENCER SR64 GRY IVE
DOOR CLOSER TO BE MOUNTED TOP-JAMB IN THE FLUSH CEILING POSITION (CLOSER
WILL REQUIRE DROP PLATE) TO PROVIDE CLEARANCE FOR THE OVERHEAD STOPS.
HW SET: 05 (CLOSETS)
3 EA HINGE 5BB1 4.5 X 4.5 NRP 652 IVE
1 EA STOREROOM LOCK ND80 626 SCH
2 EA WALL STOP WS407CVX 630 IVE
2 EA SILENCER SR64 GRY IVE
HW SET: 06 (CORRIDOR, LAUNDRY, COMMON ROOM)
3 EA HINGE 5BB1 4.5 X 4.5 NRP 652 IVE
1 EA STOREROOM LOCK ND80 626 SCH
1 EA SURFACE CLOSER SC71 RW/PA 689 FAL
2 EA WALL STOP WS407CVX 630 IVE
2 EA SILENCER SR64 GRY IVE
1 SET ADHESIVE SEAL 105 DHS
DOOR CLOSER TO BE MOUNTED TOP-JAMB IN THE FLUSH CEILING POSITION (CLOSER
WILL REQUIRE DROP PLATE) TO PROVIDE CLEARANCE FOR THE OVERHEAD STOPS.
HW SET: 07 (MECHANICAL, MAINTENANCE, JANITOR)
3 EA HINGE 5BB1 4.5 X 4.5 652 IVE
1 EA STOREROOM LOCK ND80 X TACTILE WARNING 626 SCH
1 EA SURFACE CLOSER SC71 RW/PA 689 FAL
1 EA WALL STOP WS407CVX 630 IVE
3 EA SILENCER SR64 GRY IVE
1 SET ADHESIVE SEAL 105 DHS
SECTION 08710 FINISH HARDWARE
OXOBOXO LOFTS SECTION 08710 - PAGE 17 of 19
DOOR CLOSER TO BE MOUNTED TOP-JAMB IN THE FLUSH CEILING POSITION (CLOSER
WILL REQUIRE DROP PLATE) TO PROVIDE CLEARANCE FOR THE OVERHEAD STOPS.
HW SET: 08 (ELECTRICAL)
3 EA HINGE 5BB1 4.5 X 4.5 652 IVE
1 EA PANIC DEVICE 25-R-NL 26D FAL
1 EA STOREROOM LOCK ND80 X TACTILE WARNING 626 SCH
1 EA SURFACE CLOSER SC71 RW/PA 689 FAL
1 EA WALL STOP WS407CVX 630 IVE
3 EA SILENCER SR64 GRY IVE
1 SET ADHESIVE SEAL 105 DHS
DOOR CLOSER TO BE MOUNTED TOP-JAMB IN THE FLUSH CEILING POSITION (CLOSER
WILL REQUIRE DROP PLATE) TO PROVIDE CLEARANCE FOR THE OVERHEAD STOPS.
HW SET: 09 (MECHANICAL PAIR)
6 EA HINGE 5BB1 4.5 X 4.5 652 IVE
1 EA FLUSH BOLT FB458 626 IVE
1 EA STOREROOM LOCK ND80 X TACTILE WARNING 626 SCH
2 EA WALL STOP WS407CVX 630 IVE
3 EA SILENCER SR64 GRY IVE
2 EA SURFACE CLOSER SC71 RW/PA 689 FAL
1 SET ADHESIVE SEAL 105 DHS
DOOR CLOSER TO BE MOUNTED TOP-JAMB IN THE FLUSH CEILING POSITION (CLOSER
WILL REQUIRE DROP PLATE) TO PROVIDE CLEARANCE FOR THE OVERHEAD STOPS.
HW SET: 10 (STAIR INTERIOR)
3 EA HINGE 5BB1 4.5 X 4.5 652 IVE
1 EA FIRE EXIT DEVICE F-25-R-L-BE 26D FAL
1 EA STOREROOM LOCK ND80 626 SCH
1 EA SURFACE CLOSER SC71 RW/PA 689 FAL
1 EA KICK PLATE 8400 630 IVE
1 EA WALL STOP WS407CVX 630 IVE
1 SET ADHESIVE SEAL 105 DHS
DOOR CLOSER TO BE MOUNTED TOP-JAMB IN THE FLUSH CEILING POSITION (CLOSER
WILL REQUIRE DROP PLATE) TO PROVIDE CLEARANCE FOR THE OVERHEAD STOPS.
HW SET: 11 (APARTMENT ENTRY)
3 EA HINGE 5BB1 4.5 X 4.5 619 IVE
1 EA ENTRANCE
W/DEADBOLT
L9456T 07A L583-363 619 SCH
1 EA SURFACE CLOSER SC71 RW/PA 689 FAL
SECTION 08710 FINISH HARDWARE
OXOBOXO LOFTS SECTION 08710 - PAGE 18 of 19
1 EA DOOR STOP 61B 619 IVE
1 SET DOOR SEAL DS69C AL REE
1 EA SWEEP 354C AL REE
1 EA THRESHOLD S425A AL REE
1 EA VIEWER 698B 619 IVE
VERIFY WHETHER GASKETING AND THRESHOLD ARE REQUIRED, OR IF THEY ARE
SUPPLIED WITH THE DOOR/FRAME.
WHERE DOOR SWING WILL CAUSE IT TO HIT AN ADJACENT DOOR, FURNISH IVES RB471
ROLLER BUMPER IN LIEU OF SPECIFIED BASEBOARD STOP.
HW SET: 12 (UNIT INTERIORS - BED, BATH)
3 EA HINGE 1010 3.5 X 3.5 646 IVE
1 EA PRIVACY SET F40 619 SCH
1 EA DOOR STOP 61B 619 IVE
3 EA SILENCER SR65 GRY IVE
HW SET: 13 (UNIT INTERIORS – CLOSET SINGLE)
3 EA HINGE 1010 3.5 X 3.5 646 IVE
1 EA PASSAGE SET F10 619 SCH
1 EA DOOR STOP 61B 619 IVE
3 EA SILENCER SR65 GRY IVE
HW SET: 14 (UNIT INTERIORS - CLOSET PAIR)
6 EA HINGE 1010 3.5 X 3.5 646 IVE
2 EA SGL DUMMY TRIM F170 619 SCH
2 EA DOOR STOP 61B 619 IVE
2 EA SILENCER SR65 GRY IVE
1 EA MAGNETIC CATCH 327 673 IVE
HW SET: 15 (APARTMENT ENTRY, EXTERIOR DOOR)
3 EA HINGE 5BB1 4.5 X 4.5 619 IVE
1 EA ENTRANCE
W/DEADBOLT
L9456T 07A L583-363 619 SCH
1 EA DOOR STOP 61B 619 IVE
1 SET DOOR SEAL DS69C AL REE
1 EA SWEEP 354C AL REE
1 EA THRESHOLD S425A AL REE
1 EA VIEWER 698B 619 IVE
HW SET: 16 (CRAWL ACCESS, EXTERIOR DOOR)
2 EA HINGE 5BB1 4.5 X 4.5 619 IVE
1 EA STOREROOM LOCK ND80 X TACTILE WARNING 626 SCH
1 EA SURFACE CLOSER SC71 RW/PA 689 FAL
1 SET DOOR SEAL DS69C AL REE
SECTION 08710 FINISH HARDWARE
OXOBOXO LOFTS SECTION 08710 - PAGE 19 of 19
1 EA SWEEP 354C AL REE
1 EA THRESHOLD S425A AL REE
END OF SECTION 08710