HomeMy WebLinkAboutP_16066_42PINKROW_R19OA
L2.2
L2.A
L2.B
L2.C
L2.D
L2.E
L2.F
L2.G
L2.H
L2.J
L2.K
L2.1
O1 O2 O3 O4 O5
W1 W2 W3 W4 W5
W6
W7 W8 W9
L2.L
BUILDING D
BUILDING B
BUILDING C
BUILDING G
BUILDING A
UNIT A-1
(2 BEDROOM)
UNIT A-2
(1 BEDROOM)
UNIT B-3
(1 BEDROOM)
TYPE 'A'
UNIT B-4(2 BEDROOM)
UNIT B-5
(1 BEDROOM)
UNIT B-6
(1 BEDROOM)
UNIT B-7
(STUDIO)
UNIT A-2
(2 BEDROOM)
WCO
4"ø W
2"ø2" W UP& DN
4"ø 3"ø 3"ø3/4"ø
4" WUP&DN
L-1
WC-1
B-1
S-1
L-1
WC-1
B-1
S-1
3" HW & 1" HWR DN
S-1
S-1
L-1
WC-1
B-1
L-1
WC-1
SH-1
L-1
WC-1
B-1
L-1
WC-1
B-1L-1
WC-1B-1
L-1
WC-1B-1
S-1
S-1
S-1
CO
2"ø2"ø
1 1/2"ø 1 1/2"ø
1 1/2"ø
2"ø
3" V UP
2"ø
1 1/2"ø
2"ø
2 1/2"ø
3" VUP
2 1/2"ø
2"ø2"ø
1 1/2"ø1 1/2"ø2"ø
3" V
UP
1 1/2"ø
2"ø2"ø
1 1/2"ø
2 1/2"ø3" VUP
2"ø
1 1/2"ø
3"ø
2"ø
2 1/2"ø
1 1/2"ø
3" VUP
1 1/2"ø
3" V UP
3" V UP
2"ø2"ø
1 1/2"ø
2 1/2"ø
2"ø
4" W UP
2"ø
HP1
2"ø
3/4" CONDENSATEDRAIN WITH INDIRECT
WASTE CONNECTION
TO NEAREST SANITARY,VERIFY LOCATION ANDROUTING IN FIELD(TYPICAL)
2"ø
2"ø
3/4" CONDENSATE DRAIN WITH
INDIRECT WASTE CONNECTION TO
NEAREST SANITARY, VERIFY LOCATIONAND ROUTING IN FIELD (TYPICAL)
HP1
HP1
HP1
HP1
3/4" CONDENSATE DRAIN WITHINDIRECT WASTE CONNECTION TONEAREST SANITARY, VERIFY LOCATIONAND ROUTING IN FIELD (TYPICAL)
3"ø
6"ø3"ø DCW3"ø DHW1"ø DHWR2"ø DCW2"ø DHW1"ø DHWR1/2"ø1/2"ø
1"ø
2"ø
2"ø
3" V UP
2"ø
6" SAN UP& DN
6"ø
HP1
S-1 4"
4"
HP1
6"ø
A B
D E
C F
G H J
K
L M
NORTH
SITE KEY PLAN
Scale
Date
Drawn By
Checked By
Project Number
UNCASVILLE, CT
1/8" = 1'-0"
ABC-PB1.1
PLUMBING PLAN
BLDG 'A'- LEVEL 1
BLDG 'B'- LEVEL 1
Dakota
Partners, Inc.
OXOBOXO
LOFTS
DA
RS
11/01/2017
16-063
No.Description Date
Arch Revisions 12/20/19
Addendum 8 11/15/19
PSK ABC-PB1.1
12/31/19PSK-ABC-PB1.1
OA
L2.2
L2.A
L2.B
L2.C
L2.D
L2.E
L2.F
L2.G
L2.H
L2.J
L2.K
L2.M
L2.N
L2.1
O1 O2 O3 O4 O5
W1 W2 W3 W4 W5
W6
W7 W8 W9
L2.L
UNIT B-8(1 BEDROOM)
TYPE A
UNIT B-9(2 BEDROOM)
UNIT B-10
(1 BEDROOM)
UNIT B-11
(1 BEDROOM)
UNIT B-12(1 BEDROOM)
BUILDING B
BUILDING C
BUILDING A
BUILDING G
BUILDING D
CW, HW & HWR TO BUILDINGS D & E,
SEE DRAWING DE-P1.1 FOR
CONTINUATION
3" V UP & DN
2"ø
1 1/2"ø
2 1/2"ø
3" V UP & DN
2 1/2"ø
2"ø2"ø
1 1/2"ø1 1/2"ø2"ø
3" V UP& DN
1 1/2"ø
2"ø2"ø
1 1/2"ø
2 1/2"ø
3" V UP& DN
2"ø
1 1/2"ø
3"ø
2"ø
2 1/2"ø
1 1/2"ø
3" V UP& DN
3/4" CONDENSATE DRAIN WITHINDIRECT WASTE CONNECTION TO
NEAREST SANITARY, VERIFY LOCATION
AND ROUTING IN FIELD (TYPICAL)
HP-1
HP1
HP-1
HP1
3/4" CONDENSATE DRAIN WITHINDIRECT WASTE CONNECTION TO
NEAREST SANITARY, VERIFY LOCATION
AND ROUTING IN FIELD (TYPICAL)
HP1
B-1
L-1
WC-1
SH-1
S-1
L-1
WC-1
B-1
S-1
L-1
WC-1
B-1
S-1
L-1
WC-1
B-1
S-1
1 1/4"ø DHW
1 1/2"ø DCW
1/2"ø DHWR
6" SAN DN
4" SAN UP
3/4" H&CW, 2" W TO WASHING MACHINE
(TYPICAL FOR 4 SETS)
S-1
WMF-1
WMF-1WMF-1
WMF-1
WC-1
FCO
4" W DN
L-1
1"ø1"ø
Scale
Date
Drawn By
Checked By
Project Number
UNCASVILLE, CT
1/8" = 1'-0"
ABC-PB1.2
PLUMBING PLAN
BLDG 'B'- LEVEL 2
Dakota
Partners, Inc.
OXOBOXO
LOFTS
DA
RS
11/01/2017
16-063
A
B
D E
C F
G H
J
K
L M
NORTH
SITE KEY PLAN
No.Description Date
Arch Revisions 12/20/19
Addendum 8 11/15/19
PSK ABC-PB1.2
12/31/19PSK-ABC-PB1.2
2"
3"
L2.2
L2.A
L2.B
L2.C
L2.D
L2.E
L2.F
L2.G
L2.H
L2.J
L2.K
L2.1
O1 O2 O3 O4 O5
W1 W2 W3 W4 W5
W6
W7 W8 W9
L2.L
BUILDING G
BUILDING D
BUILDING B
BUILDING C
BUILDING A
UNIT A-4
(1 BEDROOM)H.C.
UNIT A-5
(1 BEDROOM)
UNIT A-6(2 BEDROOM)
H.C.
UNIT B-13
(1 BEDROOM)
TYPE A
UNIT B-14(2 BEDROOM)
UNIT B-15
(1 BEDROOM)
UNIT B-16
(1
BEDROOM)
UNIT B-17
(1 BEDROOM)
1/2" C&HW &2" W DN
1" C&HW DN
3/4"ø
3/4"ø
3/4"ø
1"ø
3/4"ø
4" WDN
2"ø2"ø
2" W DN
2" W DN
4" W DN
1 1/2"ø
1 1/2"ø
2"ø
3" V UP & DN
2"ø
1 1/2"ø
2 1/2"ø
3" V UP & DN
2 1/2"ø
2"ø2"ø
1 1/2"ø1 1/2"ø2"ø
3" V UP& DN
1 1/2"ø
2"ø2"ø
1 1/2"ø
2 1/2"ø3" V UP& DN
2"ø
1 1/2"ø
3"ø
2"ø
2 1/2"ø
1 1/2"ø
3" V UP& DN
L-1
WC-1B-1
S-1
HP1
L-1
WC-1
B-1
S-1
HP1
L-1
WC-1
B-1
S-1
L-1
WC-1
SH-1
S-1
L-1
WC-1
B-1
S-1
L-1
WC-1
B-1
S-1
HP1
L-1
WC-1
B-1
S-1
3/4" CONDENSATE DRAIN WITH
INDIRECT WASTE CONNECTION TO
NEAREST SANITARY, VERIFY LOCATIONAND ROUTING IN FIELD (TYPICAL)
HP2
HP1
HP1
3/4" CONDENSATE DRAIN WITHINDIRECT WASTE CONNECTION TONEAREST SANITARY, VERIFY LOCATIONAND ROUTING IN FIELD (TYPICAL)
HP1
B-1
WC-1
3/4" CONDENSATE DRAIN WITH INDIRECT WASTECONNECTION TO NEAREST SANITARY, VERIFYLOCATION AND ROUTING IN FIELD (TYPICAL)
3" VTR 1 1/2"ø
1/2"ø1/2"ø
1 1/2"ø
2 1/2"ø
1/2"ø1/2"ø
1/2"ø1/2"ø1/2"ø
2"ø
2 1/2"ø
HP1
1 1/2"ø
4" SAN UP
& DN
Scale
Date
Drawn By
Checked By
Project Number
UNCASVILLE, CT
1/8" = 1'-0"
ABC-PB1.3
PLUMBING PLAN
BLDG 'A'- LEVEL 2
BLDG 'B'- LEVEL 3
Dakota
Partners, Inc.
OXOBOXO
LOFTS
DA
RS
11/01/2017
16-063
A
B
D E
C F
G H
J
K
L M
NORTH
SITE KEY PLAN
No.Description Date
Arch Revisions 12/20/19
Addendum 8 11/15/19
PSK ABC-PB1.3
12/31/19PSK-ABC-PB1.3
WA
L2.2
L2.A
L2.B
L2.C
L2.D
L2.E
L2.F
L2.G
L2.H
L2.J
L2.K
L2.M
L2.N
L2.1
W1 W2 W3 W4 W5
W6
W7 W8 W9
L2.L
BUILDING B
BUILDING A
UNIT B-18(1 BEDROOM)
UNIT B-19
(2 BEDROOM)
UNIT B-20
(1 BEDROOM)
UNIT B-21(1 BEDROOM)
UNIT B-22(1 BEDROOM)
ATTIC SPACE
1 1/2"ø
1 1/2"ø
2"ø
3" V UP & DN
2"ø
1 1/2"ø
2 1/2"ø
3" V UP
& DN
2 1/2"ø
2"ø2"ø
1 1/2"ø1 1/2"ø2"ø
3" V UP& DN
1 1/2"ø
2"ø2"ø
1 1/2"ø
2 1/2"ø
3" V UP & DN
2"ø
1 1/2"ø
3"ø
2"ø
2 1/2"ø
1 1/2"ø
3" V UP
& DN
3/4" CONDENSATE DRAIN WITHINDIRECT WASTE CONNECTION TONEAREST SANITARY, VERIFY LOCATIONAND ROUTING IN FIELD (TYPICAL)
HP2
HP1
HP1
HP1
3/4" CONDENSATE DRAIN WITH
INDIRECT WASTE CONNECTION TO
NEAREST SANITARY, VERIFY LOCATIONAND ROUTING IN FIELD (TYPICAL)
HP1
L-1
WC-1
B-1
S-1
L-1
WC-1
SH-1
S-1
L-1
WC-1B-1
S-1
L-1
WC-1
B-1
S-1
L-1
WC-1
B-1
S-11"ø3/4"ø1"ø3/4"ø1"ø
3/4"ø
1"ø3/4"ø
1/2"ø1/2"ø
1/2"ø1/2"ø
4" SAN DN,4" V UP
1 1/2"ø1 1/2"ø
Scale
Date
Drawn By
Checked By
Project Number
UNCASVILLE, CT
1/8" = 1'-0"
ABC-PB1.4
PLUMBING PLAN
BLDG 'A'- ATTIC
BLDG 'B'- LEVEL 4
Dakota
Partners, Inc.
OXOBOXO
LOFTS
DA
RS
11/01/2017
16-063
A
B
D E
C F
G H
J
K
L M
NORTH
SITE KEY PLAN
No.Description Date
Arch Revisions 12/20/19
Addendum 8 11/15/19
PSK ABC-PB1.4
3/4" CONDENSATE DRAINWITH INDIRECT WASTE
CONNECTION TO NEAREST
SANITARY, VERIFY LOCATIONAND ROUTING IN FIELD (TYPICAL)
BUILDING G B UPPER LEVEL
HP4
12/31/19PSK-ABC-PB1.4
OA
L2.2
L2.A
L2.B
L2.C
L2.D
L2.E
L2.F
L2.G
L2.J
L2.K
L2.M
L2.N
L2.1
O1 O2 O3 O4 O5
W1 W2 W3 W4 W5
W6
W7 W8 W9
L2.L
UNIT B-1
(2 BEDROOM)
TYPE A
UNIT B-2(2 BEDROOM)
UNIT C-3
(2 BEDROOM)
TYPE A
UNIT C-4
(2 BEDROOM)
TYPE A
ELEVATOR
BUILDING B
BUILDING C
BUILDING A
CRAWL SPACE
BUILDING G
BUILDING D
BUILDING F
1" HWR UP&DN
3" HW UP&DN
3" CW UP&DN
L-1
WC-1
B-1 S-1
L-1WC-1
B-1
S-1
L-1WC-1
B-1
S-1
L-1
WC-1
B-1
S-1
3" VDN,4"VTR
1 1/2"ø
1/2"ø1/2"ø
3/4"ø
1/2"ø
1/2"ø
3/4"ø1/2"ø
1/2"ø
1/2"ø1/2"øERV-1
HP-5
HP2
HP2
HP21"ø1/2"ø1"ø3/4"ø
3/4"ø3/4"ø1/2"ø1/2"ø
1/2"ø1/2"ø
1/2"ø1/2"ø 1/2"ø1/2"ø1/2"ø1/2"ø1/2"ø
1/2"ø
3/4" CONDENSATE DRAIN WITHINDIRECT WASTE CONNECTION TONEAREST SANITARY, VERIFY LOCATION
AND ROUTING IN FIELD (TYPICAL)
3/4" CONDENSATE DRAIN WITHINDIRECT WASTE CONNECTION TONEAREST SANITARY, VERIFY LOCATION
AND ROUTING IN FIELD (TYPICAL)
YCO
6" SANITARY FROM BUILDING B,
SEE DRAWING ABC-PB1.SB FOR
CONTINUATION
HP2
1 1/2"ø 1/2"ø1/2"ø
3/4"ø
1 1/2"ø
FCO
3/4" CW FROM
BOLOW
3/4" HW & 1/2" HWRFROM BELOW
4"ø
6" SAN UP & DN
FCO
1/2"ø1/2"ø
4"ø1 1/
2
"
ø
Scale
Date
Drawn By
Checked By
Project Number
UNCASVILLE, CT
1/8" = 1'-0"
ABC-PB1.B
PLUMBING PLAN
BLDG A-CRAWL SPACE
BLDG 'B'- LEVEL B
BLDG 'C'- LEVEL 2
Dakota
Partners, Inc.
OXOBOXO
LOFTS
DA
RS
11/01/2017
16-063
A
B
D E
C F
G H
J
K
L M
NORTH
SITE KEY PLAN
No.Description Date
Arch Revisions 12/20/19
Addendum 8 11/15/19
PSK ABC-PB1.B
12/31/19PSK-ABC-PB1.B
BFP
L2.2
L2.A
L2.B
L2.C
L2.D
L2.E
L2.F
L2.G
L2.H
L2.J
L2.1
L2.L
UNIT C-1
(2 BEDROOM)
UNIT C-2
(2 BEDROOM)
STAIR 2
ELECTRICAL
METERROOM
MAINTENANCE
ROOM
BUILDING B
BUILDING C
BUILDING A
(ABOVE)
BUILDING D
BUILDING G
ET2
B1
TMV1
P2
(2) 300 GALLON INDIRECT HOT WATER
STORAGE TANKS SEE 11/P3.2 FOR
PIPING DIAGRAM
GAS FIRED DOMESTICHOT WATER BOILER
FOR DOMESTIC WATERSERVICE INSTALLATIONSEE 7/P3.1
3"CW UP
6" SANITARY FROM ABOVE,
PROVIDE CLEANOUT AT BASE
OF RISER
3/4"ø
4"ø W
2"ø V
1 1/2"ø
1 1/2"ø
1 1/2"ø
4"ø W1 1/2" V UP
1 1/2" V UP
1/2" H&CW DNTYP OF BATHTUB3/4"ø DHWR
4" SANITARY FROM BUILDING E,
SEE DRAWING DE-PB1.1 FORCONTINUATION
3"HW UP
1"HWR FROM ABOVE
S-1
L-1
WC-1
B-1
WC-1
L-1
S-1
6" SANITARY TO BUILDING F,SEE DRAWING F-PB1.1 FORCONTINUATION
1 1/4" GAS FROMBUILDING F, SEEDRAWING F-PB1.1 FORCONTINUATION
2"ø DCW
3/4" HW AND
1/2" HWR UP
3/4" CWUP
L-1
1 1/2" CW TO BUILDING F,SEE DRAWING F-PB1.1FOR CONTINUATION
B-1
SANITARY PIPING FROM
RESPECTIVE FIXTURES
ABOVE (TYPICAL FOR ALL)
SANITARY PIPING FROMRESPECTIVE FIXTURESABOVE (TYPICAL FOR ALL)
3/4" CONDENSATE DRAIN WITHINDIRECT WASTE CONNECTION TONEAREST SANITARY, VERIFY LOCATION
AND ROUTING IN FIELD (TYPICAL)
1 1/2"ø
CWFCO
CO
YCO
3"ø
3" SANITARY FROM BUILDING F,SEE DRAWING F-PB1.1 FOR CONTINUATION
ET1
G G
PRESSURE REDUCING VALVE BYPLUMBING CONTRACTOR, SIZE ASPER BOILER REQUIREMENTSG
4"ø
2"ø
P1
AS1
AS2
3"ø
4" CW SERVICE IN, SEESITE UTILITY PLAN FORCONTINUATION
SPRINKLER SERVICE, FIREDEPT CONNECTION ANDBACKFLOW EQUIPTMENT,SEE FIRE PROTECTIONDRAWINGS
G
6"ø
HP23" V UP
4"ø
NEW SERVICE EJECTOR PIT WITHDUPLEX PUMP SET.PROVIDE ACCESSIBLE CHECK VALVEON DISCHARGE CONNECTION TOGRAVITY SANITARY AS REQUIRED
AND VENT CONNECTION AS SHOWN.
"HOMA" GRINDER SERIES#GRP16/3, OR APPROVED EQUAL.1.5HP, 208V, 3, 25 GPM, 14 FT. HD.FIBERGLASS BASIN WITH ACCESSIBLECOVER, DUPLEX CONTROL PANEL
CO
FD-1
2"ø 2 1/2"ø
FD-1 4"ø2"ø
HP2
4"3"øScale
Date
Drawn By
Checked By
Project Number
UNCASVILLE, CT
1/8" = 1'-0"
ABC-PB1.SB
PLUMBING PLAN
BLDG 'B'- LEVEL SB
BLDG 'C'- LEVEL 1
Dakota
Partners, Inc.
OXOBOXO
LOFTS
DA
RS
11/01/2017
16-063
A
B
D E
C F
G H
J
K
L M
NORTH
SITE KEY PLAN
No.Description Date
Arch Revisions 12/20/19
Addendum 8 11/15/19
PSK ABC-PB1.SB
12/31/19PSK-ABC-PB1.SB
DN
1
A
B
2
OA
O1 O2 O3 O4 O5
BUILDING D
UNIT D-1(2 BEDROOM)
UNIT D-2
(1 BEDROOM)
RECEPTION
OFFICE
KITCHEN
OFFICE
WAITING
AREA
HC LAV.
JAN.
MECH'L
CONFROOM
FITNESSROOM
BUILDING E
1/2"ø DCW
1/2"ø DCW
1/2"ø DHW
1" C&HW UP
1/2"C&HW
UP 1 1/2"CW & 1 1/4"HW UP
1/2"ø
1/2"ø1/2"ø1"ø DHW
1"ø DCW 1/2"ø
1/2"ø1/2"ø1/2"ø1/2"ø
2"ø WCO
1 1/2"ø W
4"ø4"ø W
4"ø W UP
2"ø W
2"ø
4"ø
1 1/2"ø
4"ø
4"ø W
1 1/2" W UP
4" SANITARY TO BUILDING F,SEE DRAWING F-PB1.1 FORCONTINUATION
LEVEL 1
1 1/2"ø
1 1/2"ø
3" V UP
2 1/2"ø
2"ø2"ø
1 1/2"ø
1 1/2"ø
1 1/2"ø
2"ø2"ø
2 1/2"ø V UP
2 1/2"ø
1 1/2"ø
2"ø
S-1
S-1
L-1
L-1
WC-1
WC-1
L-1
B-1
S-1
HP7
HP7
BEDROOM
STAIRS D1
BEDROOM
4" W DN, PROVIDEWALL CLEANOUT ATBASE OF RISER
2"ø
BEDROOM
1/2"ø1/2"øWC-1
2"ø
3/4" CONDENSATE DRAIN WITH
INDIRECT WASTE CONNECTION
TO NEAREST SANITARY, VERIFYLOCATION AND ROUTING IN FIELD (TYPICAL)
3/4" CONDENSATE DRAIN WITHINDIRECT WASTE CONNECTION
TO NEAREST SANITARY, VERIFY
LOCATION AND ROUTING IN FIELD (TYPICAL)
B-1
2"ø2"ø
HP1
HP2
YCO
FCO
4"ø
FCO
1
A
B
2
OA
O1 O2 O3 O4 O5
BUILDING D BUILDING E
UNIT D-3
(2 BEDROOM)
UNIT D-4
(1 BEDROOM)
UNIT E-2
(1 BEDROOM)
UNIT E-3
(2 BEDROOM)
1 1/2"ø1 1/4"ø1/2"ø
1/2"ø1/2"ø
1 1/2"ø
1/2"ø1/2"ø1/2"ø
1" C&HW DN 3/4"ø1/2"ø1/2"ø
3/4"ø3/4"ø
1/2"ø DHWR
1"ø DHW1"ø DCW1/2"ø1/2"ø
1/2"ø1/2"ø1/2"ø
1 1/4"ø1"ø1/2"ø1/2"ø1"ø 1 1/4"ø1/2"ø1/2" CW&HW DN
1 1/4"ø
1/2"ø1/2"ø1/2"ø1/2"ø1/2"ø1/2"ø
DCW DHWDHWR
1"ø DCW1 1/4"ø DHW1/2"ø DHWR
1 1/2" CW &1 1/4" HWDN 4"ø W DN
4"ø W DN
1/2"ø
1 1/2"ø W
1 1/2"ø
2"ø 4"ø
1 1/2" W DN
4" W DN
2" W DN
1 1/2" W DN
LEVEL 2
1 1/2" W DN
4" W DN
3" V DN&UPTO 4" VTR
1 1/2"ø
1 1/2"ø
2"ø2"ø
1 1/2"ø
1 1/2"ø
2"ø
1 1/2"ø 2"ø2"ø 2 1/2"ø2 1/2"ø
4"ø 4" VENT
TO VTR
2 1/2"ø
1 1/2"ø2"ø
2"ø
HP2
HP2
3/4" CONDENSATE DRAIN WITHINDIRECT WASTE CONNECTION
TO NEAREST SANITARY, VERIFY
LOCATION AND ROUTING IN FIELD(TYPICAL)
3/4" CONDENSATE DRAIN WITHINDIRECT WASTE CONNECTIONTO NEAREST SANITARY, VERIFYLOCATION AND ROUTING IN FIELD(TYPICAL)HP1
HP1
1 1/2"
Scale
Date
Drawn By
Checked By
Project Number
UNCASVILLE, CT
1/8" = 1'-0"
DE-PB1.1
PLUMBING PLAN
BLDGS 'D' AND 'E'-
LEVEL 1 AND 2
Dakota
Partners, Inc.
OXOBOXO
LOFTS
DA
RS
11/01/2017
16-063
A
B
D E
C F
G H
J
K
L M
NORTH
SITE KEY PLAN
S-1 S-1
S-1
S-1
L-1
WC-1
B-1
B-1
WC-1 L-1
B-1
L-1
L-1
WC-1
WC-1
B-1
ELECTRICALROOM
No.Description Date
Revision 5 06/10/19
Arch Revisions 12/20/19
Addendum 8 11/15/19
PSK DE-PB1.1
12/31/19PSK DE-PB1.1
3" W TO BLDG 'C',SEE DRAWINGABC-PB1.SB FOR
CONTINUATION
1 1/2" CW FROM BLDG 'C',
SEE DRAWING
ABC-PB1.SB FORCONTINUATION
1" CW MAKE UP TO
BOILER LOOP
LEVEL 1
INCOMING GAS SERVICEAND METER BY LOCALUTILITY COMPANY.SEE SITE UTILITY PLANFOR CONTINUATION
GAS ON TOBELOW SLAB
3"ø
FCO GG6" W FROM ABOVE, SEE LEVEL 2THIS SHEET FOR CONTINUATION.
PROVIDE CLEANOUT AT BASE OF
RISER
GG
B-1 B-1
SUMP
6" W TO BLDG 'G', SEEDRAWING G-PB1.1FOR CONTINUATION
1" CW FILL FOR
SUMP TANK
1 1/4" GAS TO BLDG 'B', SEEDRAWING ABC-PB1.1 FORCONTINUATION
CO GG
3"ø
3"ø
3"ø
2"3"
CHEMICAL TREATMENTSYSTEMS FOR COOLINGTOWER AND SOURCE WATERLOOPS AS SPECIFIED AND
DETAILED. COORDINATE
EQUIPMENT, PUMP AND ACCESSORYSELECTION, INSTALLATION ANDOPERATION WITH COOLING TOWERMANUFACTURER
3/4"ø
1 1/4" CW UP
1 1/4"ø
AREA RESERVED FOR
SVE EQUIPMENT
2" V UP
FD-1
HX-1 1 1/4"ø
1"ø
FD-1
3/4" CONDENSATEDRAIN FROM ABOVE
1 1/4" GAS TO BLDG 'G', SEEDRAWIN G-PB1.1 FORCONTINUATION
SAND FILTRATION EQUIPMENTWITH BACKWASH TANK ANDCONTROL PANEL AS SPECIFIED ANDDETAILED. COORDINATEEQUIPMENT, PUMP AND ACCESSORYSELECTION, INSTALLATION ANDOPERATION WITH COOLING TOWER
MANUFACTURER, PROVIDE MINIMUM
3/4" CW CONNECTION AND 1 1/2"BACKWASH DRAIN PIPING TO FLOORDRAIN
1 1/4" GAS OUT TO GENERATORSEE SITE UTILITY PLAN FOR
CONTINUATION
1 1/4"
3"2 1/2"
2"
1 1/2"
2 1/2"
1 1/4" GAS TO BOILER. PROVIDE
PRESSURE REDUCING VALVEIN ACCECIBLE LOCATION.COORDINATE SIZE AND VENTINGREQUIREMENTS WITH BOILERMANUFACTURER (TYPICAL FOR 2)
FD-1
CF-1
CF-2
1 1/2"ø1 1/4"
LEVEL 2
G
2"ø
6" W FROM
BLDGS 'B' 'D' &
'E', SEEDRAWING ABC-PB1.SB FORCONTINUATION
G
"GAS FROM BELOW,SEE LEVEL 1 THISSHEET FORCONTINUATION
2" GAS OUT TO GENERATOR,
SEE SITE UTILITY PLAN FORCONTINUATION
6" W DN, SEE LEVEL 1 THIS SHEETFOR CONTINUATION
HP9
3/4" CONDENSATEDRAIN DN
6"
2" V FROM BELOW
TO 2" VTR
ROOF
CT-1
1 1/4" CW MAKE UPTO COOLING TOWER
1 1/4"ø
Scale
Date
Drawn By
Checked By
Project Number
UNCASVILLE, CT
1/8" = 1'-0"
F-PB1.1
PLUMBING PLAN
BUILDING 'F'-
LEVEL 1, LEVEL 2
AND MEZZANINE
Dakota
Partners, Inc.
OXOBOXO
LOFTS
DA
RS
11/01/2017
16-063
A
B
D E
C F
G H
J
K
L M
NORTH
SITE KEY PLAN
No.Description Date
Arch Revisions 12/20/19
PSK F-PB1.1
12/31/19PSK F-PB1.1
BUILDING
H
BUILDING G
4"ø
UNIT G-5(2 BEDROOM)UNIT G-6
(1 BEDROOM)UNIT G-7
(1 BEDROOM)
UNIT G-8
(1 BEDROOM)UNIT G-9(2 BEDROOM)
UNIT G-4
(1 BEDROOM)
UNIT G-3
(1 BEDROOM)UNIT G-2(1 BEDROOM)
UNIT G-1(2 BEDROOM)
6"ø
3/4"ø
3/4"ø
1/2"ø
3/4"ø
3/4"ø 1/2"ø1/2"ø1/2"ø
1/2"ø3/4"ø
1"ø
6"ø
3/4"ø
1/2"ø
S-1
S-1S-1
S-1 S-1
S-1S-1
S-1
S-1
WC-1
WC-1
WC-1 WC-1
WC-1
WC-1
WC-1
WC-1
WC-1
L-1
L-1
L-1 L-1
L-1
L-1
L-1
L-1
B-1
B-1B-1
B-1B-1
B-1
B-1
B-1B-1
1/2"ø1/2"ø
1/2"ø1/2"ø 1/2"ø1/2"ø
1/2"ø1/2"ø
4" VTR
BUILDING K
6" SANITARY FROM BUILDING F, SEE DRAWINGF-PB1.1 FOR CONTINUATION
SAN, CW, HW & HWR
TO BUILDING, SEEDRAWING HK-PB1.1 FORCONTINUATION
FCO
1/2"ø
1/2"ø
1/2"ø
1/2"ø
3/4"ø
1 1/2"ø
2"ø2"ø
3"ø 1 1/2"ø 1 1/2"ø
1 1/2"ø
1"ø
1"ø
3/4"ø3/4"ø
1/2"ø1/2"ø
3/4"ø
SIMILAR TOUNIT G-6 SIMILAR TO
UNIT G-7
1/2"ø1/2"ø
2"ø4"ø2"ø
3/4"ø
3/4"ø
2"ø 2 1/2"ø 3"ø
L-1
4" VTR
4"ø
3/4"ø
2"ø2"ø
2"ø2"ø
1 1/2"ø
2"ø
HP1
HP2
3/4" CONDENSATE DRAIN WITH INDIRECT WASTECONNECTION TO NEAREST SANITARY, VERIFYLOCATION AND ROUTING IN FIELD (TYPICAL)
3/4"ø
HP1
HP1 HP1
2"ø
1 1/2"ø
2"ø
3/4"ø3/4"ø
1/2"ø1/2"ø
1 1/2"ø
2"ø
3/4"ø3/4"ø
1 1/2"ø
2"ø 2"ø
2"ø
1 1/2"ø
1/2"ø1/2"ø
3/4"ø3/4"ø
2"ø 2"ø
1 1/2"ø
3/4"ø3/4"ø
1 1/4"ø
1 1/2"ø
1 1/4" GAS UP ALONG WALL AND ACROSS ROOF
OF BUILDING G ADJACENT TO HIGHER ROOFOF BUILDING H. PAINT, ATTACH AND INSTALLPER SPECIFICATIONS
1 1/4" GAS FROM BUILDING F, SEE DRAWINGF-PB1.1 FOR CONTINUATION
GG1 1/2" GAS FROM ROOF INTOMECHANICAL ROOM OFBUILDING H. SEE DRAWINGHK-PB1.1 FOR CONTINUATION6"ø6"ø
G
FCO
1 1/2"ø
HP2
HP1
HP1
HP1
Scale
Date
Drawn By
Checked By
Project Number
UNCASVILLE, CT
1/8" = 1'-0"
G-PB1.1
PLUMBING PLAN
BUILDING G
Dakota
Partners, Inc.
OXOBOXO
LOFTS
DA
RS
11/01/2017
16-063
A
B
D E
C F
G H
J
K
L M
NORTH
SITE KEY PLAN
No.Description Date
Arch Revisions 12/20/19
Addendum 8 11/15/19
PSK G-PB1.1
12/31/19PSK G-PB1.1
BFPBFP
UNIT H-2
(2 BEDROOM)
METERROOM
LAUNDRY
ROOMLOBBY
BUILDING H
(2) 300 GALLONINDIRECT HOT WATER
STORAGE TANKS,
SEE 11/P3.2 FORPIPING DIAGRAM
GAS FIRED DOMESTIC
HOT WATER BOILER
UNIT H-1(1 BEDROOM)
BOILER AND
SPRINKLER
ROOM
JANITOR
BUILDING J
BUILDING K
TMV1
B1
ET1
AS-1
3/4"ø DHWR
1"ø DHW
6"ø W
3/4"ø3/4"ø1 1/2"ø
1 1/4"ø
UNIT K-2
(1 BEDROOM)UNIT K-4
(1 BEDROOM)
UNIT K-1
(1 BEDROOM)UNIT K-3
(1 BEDROOM)
P-1 P-2
3"ø 3/4"ø
S-1
L-1
WC-11 1/4"ø2"øFD-13"ø
B-1L-1
WC-1
B-1
3/4" H&CW TO WASHING MACHINESUPPLY MANIFOLD, PROVIDELAUNDRY MATE CONNECTION FOREACH UNIT AS SCHEDULED WMF-1
WMF-1
WMF-1
3/4"ø3/4"ø
3" STANDPIPE FORWASHING MACHINEINDIRECT DRAIN
S-1
L-1
WC-1 B-1
1"ø DCW
2"ø
L-1
L-1WC-1
WC-1
B-1
B-1
S-1
B-1
S-1
S-1
FCO
1 1/2"ø
2"ø2 1/2"ø
3"ø
4"ø
1 1/2"ø 2 1/2"ø
4" VTR
2 1/2"ø
4" VTR
2"ø
1 1/2"ø
2"ø
SAN, CW, HW & HWR TOBUILDING G, SEE DRAWING
G-PB1.1 FOR CONTINUATION
SAN, CW, HW & HWR TOBUILDING J, SEE DRAWINGJ-PB1.1 FOR CONTINUATION
SAN, CW, HW & HWRTO BUILDINGS L & M,SEE DRAWING LM-PB1.1
FOR CONTINUATION
HP8
HP8
HP1
HP6
HP1
HP1
HP2
3/4" CONDENSATE DRAIN WITHINDIRECT WASTE CONNECTION TONEAREST SANITARY, VERIFY LOCATION
AND ROUTING IN FIELD (TYPICAL)
1/2"ø1/2"ø
3/4"ø
3/4"ø
1/2"ø1/2"ø
3/4"ø3/4"ø
6"ø
FCO
4"ø 4"ø
FCO
1 1/4" GAS FROM ROOFABOVE, SEE DRAWINGG-PB1.1 FORCONTINUATION. PROVIDEPRESSURE REDUCINGVALVE IN ACCESSIBLELOCATION. COORDINATE
SIZE AND VENTING
REQUIREMENTS WITHBOILER MANUFACTURER
6"ø
1 1/2"ø
2 1/2"ø
1/2"ø1/2"ø1 1/2"ø
HP1
1/2"ø1/2"ø
1 1/2"ø
1 1/2"ø
S-1
1 1/2"ø1 1/2"ø 1 1/2"ø L-1
3/4"ø3/4"ø
3"ø
WC-1
2"ø
1 1/2"ø
1 1/2"ø
3"ø
SS-1
1 1/2"ø1 1/2"ø
Scale
Date
Drawn By
Checked By
Project Number
UNCASVILLE, CT
1/8" = 1'-0"
HK-PB1.1
PLUMBING PLAN
BLDGS 'H' & 'K'- LEVEL
1
Dakota
Partners, Inc.
OXOBOXO
LOFTS
DA
RS
11/01/2017
16-063
A
B
D E
C F
G H
J
K
L M
NORTH
SITE KEY PLAN
No.Description Date
Arch Revisions 12/20/19
Addendum 8 11/15/19
PSK HK-PB1.1
PSK-HK-PB1.1 12/31/19
BUILDING J
UNIT J-8(2 BEDROOM)
UNIT J-7
(1 BEDROOM)
UNIT J-6
(2 BEDROOM)
UNIT J-3
(2 BEDROOM)
UNIT J-2
(2 BEDROOM)UNIT J-1
(2 BEDROOM)
UNIT J-5
(2 BEDROOM)
UNIT J-4
(2 BEDROOM)
FCO
3/4"ø
1"ø
3/4"ø
1"ø 3/4"ø3/4"ø
3/4"ø3/4"ø
3/4"ø3/4"ø
3/4"ø3/4"ø
3/4"ø3/4"ø 1/2"ø 1/2"ø
1/2"ø 1/2"ø
L-1
B-1WC-1 L-1
B-1 WC-1
S-1
S-1
L-1
L-1
HP2
HP1WC-2 WC-1B-1 B-1
BUILDING H
S-1
S-1
S-1
S-1
S-1
S-14" VTR
3/4" CONDENSATE DRAIN WITHINDIRECT WASTE CONNECTION TO
NEAREST SANITARY, VERIFY LOCATION
AND ROUTING IN FIELD (TYPICAL)
HP3
HP1
HP3
L-1
WC-1B-1
L-1WC-1B-1
B-1
WC-1
WC-1WC-1 WC-1B-1B-1
B-1
L-1
L-1
L-1
L-1
4" VTR
4" VTR
2"ø
2"ø
3"ø
4" VTR 4" VTR
1/2"ø1/2"ø
1 1/2"ø
3"ø
3/4"ø
3/4"ø3/4"ø
3"ø
1/2"ø1/2"ø
1"ø 3/4"ø
1/2"ø
1/2"ø1/2"ø
1/2"ø1/2"ø
2"ø
1"ø
1/2"ø
1/2"ø1/2"ø
1"ø
3/4"ø
1"ø
3/4"ø
2"ø
2"ø
3"ø
4"ø
2"ø
1/2"ø1/2"ø
4"ø
1 1/2"ø1/2"ø1/2"ø1/2"ø1/2"ø1/2"ø
1/2"ø1/2"ø
3"ø
4"ø
1 1/2"ø
2"ø
4"ø 2"ø 3"ø3"ø 2"ø 4"ø
2"ø
2"ø2 1/2"ø2 1/2"ø
1 1/2"ø1 1/2"ø
3"ø3"ø
1 1/2"ø
2"ø
1/2"ø
1 1/2"ø
4"ø
1 1/2"ø
2"ø
2"ø
4"ø
1 1/2"ø
FCO
1 1/2"ø 2"ø2"ø
2"ø 4"ø
3"ø3"ø 2"ø4"ø
1 1/2"ø
3"ø3"ø2 1/2"ø2 1/2"ø
1 1/2"ø
NEW SEWAGE EJECTOR PITWITH DUPLEX PUMP SET.PROVIDE ACCESSIBLE CHECKVALVE ON DISCHARGE
CONNECTION TO GRAVITY
SANITARY AS REQUIREDAND VENT CONNECTIONAS SHOWN. "HOMA" GRINDER SERIES#GRP16/3, OR APPROVED EQUAL.1.5HP, 208V, 3 PH, 45 GPM, 9 FT. HD.FIBERGLASS BASIN WITH ACCESSIBLE
COVER, DUPLEX CONTROL PANEL
2"ø
1 1/2"ø 2"ø
FCO
HP2
HP2
4"ø
HP2
2"ø
Scale
Date
Drawn By
Checked By
Project Number
UNCASVILLE, CT
1/8" = 1'-0"
J-PB1.1
PLUMBING PLAN
BUILDING 'J'-
LEVEL 1
Dakota
Partners, Inc.
OXOBOXO
LOFTS
DA
RS
11/01/2017
16-063
A
B
D E
C F
G H
J
K
L M
NORTH
SITE KEY PLAN
No.Description Date
Arch Revisions 12/20/19
Addendum 8 11/15/19
PSK J-PB1.1
PSK J-PB1.1 12/31/19
STORAGE
3
3"ø
3/4"ø
3/4"ø1/2"ø1/2"ø
3/4"ø3/4"ø 3"ø
3"ø
3"ø
2 1/2"ø2"ø2"ø1 1/4"ø1 1/4"ø1"ø
1/2"ø
4"ø
6"ø
6"ø
3/4"ø 3/4"ø
3/4"ø3/4"ø1/2"ø3/4"ø 3/4"ø3/4"ø
1"ø
1"ø
3/4"ø
1"ø
6"ø
3"ø
3/4"ø 3/4"ø
3/4"øB-1 WC-1
L-1
S-1
6" SANITARY, 1 1/4"
HW AND 3/4" HWR
FROM BUILDINGK. SEE DRAWINGHK-PB 1.1 FORCONTINUATION
2" CW FROM BUILDING K.SEE DRAWING HK-PB1.1FOR CONTINUATION
6" SANITARY OUT,WITH ACCESSIBLE BACKFLOWVALVE. SEE SITE UTILITY PLANFOR CONTINUATION
3" CW SERVICE IN,
SEE SITE UTILITY PLANFOR CONTINUATIONFOR DOMESTIC WATERSERVICE INSTALLATIONSEE 7/P3.1
FIRE PROTECTIONSERVICE IN WITHBACKFLOW PREVENTER,SEE DRAWING LM-FP1.1
UNIT M-6(2 BEDROOMS)
UNIT M-7
(2 BEDROOMS)
UNIT M-8
(2 BEDROOMS)
UNIT M-9(2 BEDROOMS)
UNIT M-10(2 BEDROOMS)
UNIT M-11
(2 BEDROOMS)
UNIT M-5(2 BEDROOMS)
UNIT M-4(2 BEDROOMS)
UNIT M-3(2 BEDROOMS)
UNIT M-2
(2 BEDROOMS)
UNIT M-1(1 BEDROOM)
BUILDING M
L-1
WC-1B-1B-1WC-1
L-1
S-1S-1
L-1WC-1B-1B-1WC-1L-1
S-1
S-1
L-1 S-1
WC-1B-1
S-1
L-1 WC-1
B-1
S-1
L-1 WC-1 B-1
S-1
S-1
S-1
L-1
L-1
L-1
L-1
B-1
B-1
B-1B-1
WC-1
WC-1
WC-1WC-1
HP2
HP1 HP1
HP1
HP1
HP2
HP2
2"ø
1/2"ø
1/2"ø
4" VTR
4" VTR
1 1/2"ø
1/2"ø1/2"ø
2"ø
3/4"ø3/4"ø
1/2"ø
2"ø 4"ø2"ø
3"ø
2"ø
1/2"ø1/2"ø 1/2"ø1/2"ø
2"ø4"ø 2"ø 2"ø 4"ø2"ø
3/4"ø 1/2"ø1/2"ø
1/2"ø1/2"ø
1/2"ø
1/2"ø1/2"ø
6"ø
1 1/2"1 1/2"
2"1 1/2"2"
4" VTR
2"
2 1/2"
4"ø
1 1/2"
1 1/2"
4" VTR
1 1/2"1/2"ø1/2"ø
2"
2"
1 1/2"ø
2"ø
1 1/2"
1 1/2"
4"ø4"ø
1/2"ø
2"ø
3/4" CONDENSATE DRAIN WITHINDIRECT WASTE CONNECTIONTO NEAREST SANITARY, VERIFYLOCATION AND ROUTING IN
FIELD (TYPICAL)
6"ø
2"ø
1 1/2"ø
6"ø
1 1/2"
2"
4"ø
2"ø
HP-2
HP1
4"
HP-1
HP2
HP2
HP1
HP1
FCO
Scale
Date
Drawn By
Checked By
Project Number
UNCASVILLE, CT
1/8" = 1'-0"
LM-PB1.1
PLUMBING PLAN
BUILDINGS L AND M
LEVEL 1
Dakota
Partners, Inc.
OXOBOXO
LOFTS
DA
RS
11/01/2017
16-063
A
B
D E
C F
G H
J
K
L M
NORTH
SITE KEY PLAN
No.Description Date
Arch Revisions 12/20/19
Addendum 8 11/15/19
PSK LM-PB1.1
PSK-LM-PB1.1 12/31/19