Loading...
HomeMy WebLinkAboutP_16066_42PINKROW_R19OA L2.2 L2.A L2.B L2.C L2.D L2.E L2.F L2.G L2.H L2.J L2.K L2.1 O1 O2 O3 O4 O5 W1 W2 W3 W4 W5 W6 W7 W8 W9 L2.L BUILDING D BUILDING B BUILDING C BUILDING G BUILDING A UNIT A-1 (2 BEDROOM) UNIT A-2 (1 BEDROOM) UNIT B-3 (1 BEDROOM) TYPE 'A' UNIT B-4(2 BEDROOM) UNIT B-5 (1 BEDROOM) UNIT B-6 (1 BEDROOM) UNIT B-7 (STUDIO) UNIT A-2 (2 BEDROOM) WCO 4"ø W 2"ø2" W UP& DN 4"ø 3"ø 3"ø3/4"ø 4" WUP&DN L-1 WC-1 B-1 S-1 L-1 WC-1 B-1 S-1 3" HW & 1" HWR DN S-1 S-1 L-1 WC-1 B-1 L-1 WC-1 SH-1 L-1 WC-1 B-1 L-1 WC-1 B-1L-1 WC-1B-1 L-1 WC-1B-1 S-1 S-1 S-1 CO 2"ø2"ø 1 1/2"ø 1 1/2"ø 1 1/2"ø 2"ø 3" V UP 2"ø 1 1/2"ø 2"ø 2 1/2"ø 3" VUP 2 1/2"ø 2"ø2"ø 1 1/2"ø1 1/2"ø2"ø 3" V UP 1 1/2"ø 2"ø2"ø 1 1/2"ø 2 1/2"ø3" VUP 2"ø 1 1/2"ø 3"ø 2"ø 2 1/2"ø 1 1/2"ø 3" VUP 1 1/2"ø 3" V UP 3" V UP 2"ø2"ø 1 1/2"ø 2 1/2"ø 2"ø 4" W UP 2"ø HP1 2"ø 3/4" CONDENSATEDRAIN WITH INDIRECT WASTE CONNECTION TO NEAREST SANITARY,VERIFY LOCATION ANDROUTING IN FIELD(TYPICAL) 2"ø 2"ø 3/4" CONDENSATE DRAIN WITH INDIRECT WASTE CONNECTION TO NEAREST SANITARY, VERIFY LOCATIONAND ROUTING IN FIELD (TYPICAL) HP1 HP1 HP1 HP1 3/4" CONDENSATE DRAIN WITHINDIRECT WASTE CONNECTION TONEAREST SANITARY, VERIFY LOCATIONAND ROUTING IN FIELD (TYPICAL) 3"ø 6"ø3"ø DCW3"ø DHW1"ø DHWR2"ø DCW2"ø DHW1"ø DHWR1/2"ø1/2"ø 1"ø 2"ø 2"ø 3" V UP 2"ø 6" SAN UP& DN 6"ø HP1 S-1 4" 4" HP1 6"ø A B D E C F G H J K L M NORTH SITE KEY PLAN Scale Date Drawn By Checked By Project Number UNCASVILLE, CT 1/8" = 1'-0" ABC-PB1.1 PLUMBING PLAN BLDG 'A'- LEVEL 1 BLDG 'B'- LEVEL 1 Dakota Partners, Inc. OXOBOXO LOFTS DA RS 11/01/2017 16-063 No.Description Date Arch Revisions 12/20/19 Addendum 8 11/15/19 PSK ABC-PB1.1 12/31/19PSK-ABC-PB1.1 OA L2.2 L2.A L2.B L2.C L2.D L2.E L2.F L2.G L2.H L2.J L2.K L2.M L2.N L2.1 O1 O2 O3 O4 O5 W1 W2 W3 W4 W5 W6 W7 W8 W9 L2.L UNIT B-8(1 BEDROOM) TYPE A UNIT B-9(2 BEDROOM) UNIT B-10 (1 BEDROOM) UNIT B-11 (1 BEDROOM) UNIT B-12(1 BEDROOM) BUILDING B BUILDING C BUILDING A BUILDING G BUILDING D CW, HW & HWR TO BUILDINGS D & E, SEE DRAWING DE-P1.1 FOR CONTINUATION 3" V UP & DN 2"ø 1 1/2"ø 2 1/2"ø 3" V UP & DN 2 1/2"ø 2"ø2"ø 1 1/2"ø1 1/2"ø2"ø 3" V UP& DN 1 1/2"ø 2"ø2"ø 1 1/2"ø 2 1/2"ø 3" V UP& DN 2"ø 1 1/2"ø 3"ø 2"ø 2 1/2"ø 1 1/2"ø 3" V UP& DN 3/4" CONDENSATE DRAIN WITHINDIRECT WASTE CONNECTION TO NEAREST SANITARY, VERIFY LOCATION AND ROUTING IN FIELD (TYPICAL) HP-1 HP1 HP-1 HP1 3/4" CONDENSATE DRAIN WITHINDIRECT WASTE CONNECTION TO NEAREST SANITARY, VERIFY LOCATION AND ROUTING IN FIELD (TYPICAL) HP1 B-1 L-1 WC-1 SH-1 S-1 L-1 WC-1 B-1 S-1 L-1 WC-1 B-1 S-1 L-1 WC-1 B-1 S-1 1 1/4"ø DHW 1 1/2"ø DCW 1/2"ø DHWR 6" SAN DN 4" SAN UP 3/4" H&CW, 2" W TO WASHING MACHINE (TYPICAL FOR 4 SETS) S-1 WMF-1 WMF-1WMF-1 WMF-1 WC-1 FCO 4" W DN L-1 1"ø1"ø Scale Date Drawn By Checked By Project Number UNCASVILLE, CT 1/8" = 1'-0" ABC-PB1.2 PLUMBING PLAN BLDG 'B'- LEVEL 2 Dakota Partners, Inc. OXOBOXO LOFTS DA RS 11/01/2017 16-063 A B D E C F G H J K L M NORTH SITE KEY PLAN No.Description Date Arch Revisions 12/20/19 Addendum 8 11/15/19 PSK ABC-PB1.2 12/31/19PSK-ABC-PB1.2 2" 3" L2.2 L2.A L2.B L2.C L2.D L2.E L2.F L2.G L2.H L2.J L2.K L2.1 O1 O2 O3 O4 O5 W1 W2 W3 W4 W5 W6 W7 W8 W9 L2.L BUILDING G BUILDING D BUILDING B BUILDING C BUILDING A UNIT A-4 (1 BEDROOM)H.C. UNIT A-5 (1 BEDROOM) UNIT A-6(2 BEDROOM) H.C. UNIT B-13 (1 BEDROOM) TYPE A UNIT B-14(2 BEDROOM) UNIT B-15 (1 BEDROOM) UNIT B-16 (1 BEDROOM) UNIT B-17 (1 BEDROOM) 1/2" C&HW &2" W DN 1" C&HW DN 3/4"ø 3/4"ø 3/4"ø 1"ø 3/4"ø 4" WDN 2"ø2"ø 2" W DN 2" W DN 4" W DN 1 1/2"ø 1 1/2"ø 2"ø 3" V UP & DN 2"ø 1 1/2"ø 2 1/2"ø 3" V UP & DN 2 1/2"ø 2"ø2"ø 1 1/2"ø1 1/2"ø2"ø 3" V UP& DN 1 1/2"ø 2"ø2"ø 1 1/2"ø 2 1/2"ø3" V UP& DN 2"ø 1 1/2"ø 3"ø 2"ø 2 1/2"ø 1 1/2"ø 3" V UP& DN L-1 WC-1B-1 S-1 HP1 L-1 WC-1 B-1 S-1 HP1 L-1 WC-1 B-1 S-1 L-1 WC-1 SH-1 S-1 L-1 WC-1 B-1 S-1 L-1 WC-1 B-1 S-1 HP1 L-1 WC-1 B-1 S-1 3/4" CONDENSATE DRAIN WITH INDIRECT WASTE CONNECTION TO NEAREST SANITARY, VERIFY LOCATIONAND ROUTING IN FIELD (TYPICAL) HP2 HP1 HP1 3/4" CONDENSATE DRAIN WITHINDIRECT WASTE CONNECTION TONEAREST SANITARY, VERIFY LOCATIONAND ROUTING IN FIELD (TYPICAL) HP1 B-1 WC-1 3/4" CONDENSATE DRAIN WITH INDIRECT WASTECONNECTION TO NEAREST SANITARY, VERIFYLOCATION AND ROUTING IN FIELD (TYPICAL) 3" VTR 1 1/2"ø 1/2"ø1/2"ø 1 1/2"ø 2 1/2"ø 1/2"ø1/2"ø 1/2"ø1/2"ø1/2"ø 2"ø 2 1/2"ø HP1 1 1/2"ø 4" SAN UP & DN Scale Date Drawn By Checked By Project Number UNCASVILLE, CT 1/8" = 1'-0" ABC-PB1.3 PLUMBING PLAN BLDG 'A'- LEVEL 2 BLDG 'B'- LEVEL 3 Dakota Partners, Inc. OXOBOXO LOFTS DA RS 11/01/2017 16-063 A B D E C F G H J K L M NORTH SITE KEY PLAN No.Description Date Arch Revisions 12/20/19 Addendum 8 11/15/19 PSK ABC-PB1.3 12/31/19PSK-ABC-PB1.3 WA L2.2 L2.A L2.B L2.C L2.D L2.E L2.F L2.G L2.H L2.J L2.K L2.M L2.N L2.1 W1 W2 W3 W4 W5 W6 W7 W8 W9 L2.L BUILDING B BUILDING A UNIT B-18(1 BEDROOM) UNIT B-19 (2 BEDROOM) UNIT B-20 (1 BEDROOM) UNIT B-21(1 BEDROOM) UNIT B-22(1 BEDROOM) ATTIC SPACE 1 1/2"ø 1 1/2"ø 2"ø 3" V UP & DN 2"ø 1 1/2"ø 2 1/2"ø 3" V UP & DN 2 1/2"ø 2"ø2"ø 1 1/2"ø1 1/2"ø2"ø 3" V UP& DN 1 1/2"ø 2"ø2"ø 1 1/2"ø 2 1/2"ø 3" V UP & DN 2"ø 1 1/2"ø 3"ø 2"ø 2 1/2"ø 1 1/2"ø 3" V UP & DN 3/4" CONDENSATE DRAIN WITHINDIRECT WASTE CONNECTION TONEAREST SANITARY, VERIFY LOCATIONAND ROUTING IN FIELD (TYPICAL) HP2 HP1 HP1 HP1 3/4" CONDENSATE DRAIN WITH INDIRECT WASTE CONNECTION TO NEAREST SANITARY, VERIFY LOCATIONAND ROUTING IN FIELD (TYPICAL) HP1 L-1 WC-1 B-1 S-1 L-1 WC-1 SH-1 S-1 L-1 WC-1B-1 S-1 L-1 WC-1 B-1 S-1 L-1 WC-1 B-1 S-11"ø3/4"ø1"ø3/4"ø1"ø 3/4"ø 1"ø3/4"ø 1/2"ø1/2"ø 1/2"ø1/2"ø 4" SAN DN,4" V UP 1 1/2"ø1 1/2"ø Scale Date Drawn By Checked By Project Number UNCASVILLE, CT 1/8" = 1'-0" ABC-PB1.4 PLUMBING PLAN BLDG 'A'- ATTIC BLDG 'B'- LEVEL 4 Dakota Partners, Inc. OXOBOXO LOFTS DA RS 11/01/2017 16-063 A B D E C F G H J K L M NORTH SITE KEY PLAN No.Description Date Arch Revisions 12/20/19 Addendum 8 11/15/19 PSK ABC-PB1.4 3/4" CONDENSATE DRAINWITH INDIRECT WASTE CONNECTION TO NEAREST SANITARY, VERIFY LOCATIONAND ROUTING IN FIELD (TYPICAL) BUILDING G B UPPER LEVEL HP4 12/31/19PSK-ABC-PB1.4 OA L2.2 L2.A L2.B L2.C L2.D L2.E L2.F L2.G L2.J L2.K L2.M L2.N L2.1 O1 O2 O3 O4 O5 W1 W2 W3 W4 W5 W6 W7 W8 W9 L2.L UNIT B-1 (2 BEDROOM) TYPE A UNIT B-2(2 BEDROOM) UNIT C-3 (2 BEDROOM) TYPE A UNIT C-4 (2 BEDROOM) TYPE A ELEVATOR BUILDING B BUILDING C BUILDING A CRAWL SPACE BUILDING G BUILDING D BUILDING F 1" HWR UP&DN 3" HW UP&DN 3" CW UP&DN L-1 WC-1 B-1 S-1 L-1WC-1 B-1 S-1 L-1WC-1 B-1 S-1 L-1 WC-1 B-1 S-1 3" VDN,4"VTR 1 1/2"ø 1/2"ø1/2"ø 3/4"ø 1/2"ø 1/2"ø 3/4"ø1/2"ø 1/2"ø 1/2"ø1/2"øERV-1 HP-5 HP2 HP2 HP21"ø1/2"ø1"ø3/4"ø 3/4"ø3/4"ø1/2"ø1/2"ø 1/2"ø1/2"ø 1/2"ø1/2"ø 1/2"ø1/2"ø1/2"ø1/2"ø1/2"ø 1/2"ø 3/4" CONDENSATE DRAIN WITHINDIRECT WASTE CONNECTION TONEAREST SANITARY, VERIFY LOCATION AND ROUTING IN FIELD (TYPICAL) 3/4" CONDENSATE DRAIN WITHINDIRECT WASTE CONNECTION TONEAREST SANITARY, VERIFY LOCATION AND ROUTING IN FIELD (TYPICAL) YCO 6" SANITARY FROM BUILDING B, SEE DRAWING ABC-PB1.SB FOR CONTINUATION HP2 1 1/2"ø 1/2"ø1/2"ø 3/4"ø 1 1/2"ø FCO 3/4" CW FROM BOLOW 3/4" HW & 1/2" HWRFROM BELOW 4"ø 6" SAN UP & DN FCO 1/2"ø1/2"ø 4"ø1 1/ 2 " ø Scale Date Drawn By Checked By Project Number UNCASVILLE, CT 1/8" = 1'-0" ABC-PB1.B PLUMBING PLAN BLDG A-CRAWL SPACE BLDG 'B'- LEVEL B BLDG 'C'- LEVEL 2 Dakota Partners, Inc. OXOBOXO LOFTS DA RS 11/01/2017 16-063 A B D E C F G H J K L M NORTH SITE KEY PLAN No.Description Date Arch Revisions 12/20/19 Addendum 8 11/15/19 PSK ABC-PB1.B 12/31/19PSK-ABC-PB1.B BFP L2.2 L2.A L2.B L2.C L2.D L2.E L2.F L2.G L2.H L2.J L2.1 L2.L UNIT C-1 (2 BEDROOM) UNIT C-2 (2 BEDROOM) STAIR 2 ELECTRICAL METERROOM MAINTENANCE ROOM BUILDING B BUILDING C BUILDING A (ABOVE) BUILDING D BUILDING G ET2 B1 TMV1 P2 (2) 300 GALLON INDIRECT HOT WATER STORAGE TANKS SEE 11/P3.2 FOR PIPING DIAGRAM GAS FIRED DOMESTICHOT WATER BOILER FOR DOMESTIC WATERSERVICE INSTALLATIONSEE 7/P3.1 3"CW UP 6" SANITARY FROM ABOVE, PROVIDE CLEANOUT AT BASE OF RISER 3/4"ø 4"ø W 2"ø V 1 1/2"ø 1 1/2"ø 1 1/2"ø 4"ø W1 1/2" V UP 1 1/2" V UP 1/2" H&CW DNTYP OF BATHTUB3/4"ø DHWR 4" SANITARY FROM BUILDING E, SEE DRAWING DE-PB1.1 FORCONTINUATION 3"HW UP 1"HWR FROM ABOVE S-1 L-1 WC-1 B-1 WC-1 L-1 S-1 6" SANITARY TO BUILDING F,SEE DRAWING F-PB1.1 FORCONTINUATION 1 1/4" GAS FROMBUILDING F, SEEDRAWING F-PB1.1 FORCONTINUATION 2"ø DCW 3/4" HW AND 1/2" HWR UP 3/4" CWUP L-1 1 1/2" CW TO BUILDING F,SEE DRAWING F-PB1.1FOR CONTINUATION B-1 SANITARY PIPING FROM RESPECTIVE FIXTURES ABOVE (TYPICAL FOR ALL) SANITARY PIPING FROMRESPECTIVE FIXTURESABOVE (TYPICAL FOR ALL) 3/4" CONDENSATE DRAIN WITHINDIRECT WASTE CONNECTION TONEAREST SANITARY, VERIFY LOCATION AND ROUTING IN FIELD (TYPICAL) 1 1/2"ø CWFCO CO YCO 3"ø 3" SANITARY FROM BUILDING F,SEE DRAWING F-PB1.1 FOR CONTINUATION ET1 G G PRESSURE REDUCING VALVE BYPLUMBING CONTRACTOR, SIZE ASPER BOILER REQUIREMENTSG 4"ø 2"ø P1 AS1 AS2 3"ø 4" CW SERVICE IN, SEESITE UTILITY PLAN FORCONTINUATION SPRINKLER SERVICE, FIREDEPT CONNECTION ANDBACKFLOW EQUIPTMENT,SEE FIRE PROTECTIONDRAWINGS G 6"ø HP23" V UP 4"ø NEW SERVICE EJECTOR PIT WITHDUPLEX PUMP SET.PROVIDE ACCESSIBLE CHECK VALVEON DISCHARGE CONNECTION TOGRAVITY SANITARY AS REQUIRED AND VENT CONNECTION AS SHOWN. "HOMA" GRINDER SERIES#GRP16/3, OR APPROVED EQUAL.1.5HP, 208V, 3, 25 GPM, 14 FT. HD.FIBERGLASS BASIN WITH ACCESSIBLECOVER, DUPLEX CONTROL PANEL CO FD-1 2"ø 2 1/2"ø FD-1 4"ø2"ø HP2 4"3"øScale Date Drawn By Checked By Project Number UNCASVILLE, CT 1/8" = 1'-0" ABC-PB1.SB PLUMBING PLAN BLDG 'B'- LEVEL SB BLDG 'C'- LEVEL 1 Dakota Partners, Inc. OXOBOXO LOFTS DA RS 11/01/2017 16-063 A B D E C F G H J K L M NORTH SITE KEY PLAN No.Description Date Arch Revisions 12/20/19 Addendum 8 11/15/19 PSK ABC-PB1.SB 12/31/19PSK-ABC-PB1.SB DN 1 A B 2 OA O1 O2 O3 O4 O5 BUILDING D UNIT D-1(2 BEDROOM) UNIT D-2 (1 BEDROOM) RECEPTION OFFICE KITCHEN OFFICE WAITING AREA HC LAV. JAN. MECH'L CONFROOM FITNESSROOM BUILDING E 1/2"ø DCW 1/2"ø DCW 1/2"ø DHW 1" C&HW UP 1/2"C&HW UP 1 1/2"CW & 1 1/4"HW UP 1/2"ø 1/2"ø1/2"ø1"ø DHW 1"ø DCW 1/2"ø 1/2"ø1/2"ø1/2"ø1/2"ø 2"ø WCO 1 1/2"ø W 4"ø4"ø W 4"ø W UP 2"ø W 2"ø 4"ø 1 1/2"ø 4"ø 4"ø W 1 1/2" W UP 4" SANITARY TO BUILDING F,SEE DRAWING F-PB1.1 FORCONTINUATION LEVEL 1 1 1/2"ø 1 1/2"ø 3" V UP 2 1/2"ø 2"ø2"ø 1 1/2"ø 1 1/2"ø 1 1/2"ø 2"ø2"ø 2 1/2"ø V UP 2 1/2"ø 1 1/2"ø 2"ø S-1 S-1 L-1 L-1 WC-1 WC-1 L-1 B-1 S-1 HP7 HP7 BEDROOM STAIRS D1 BEDROOM 4" W DN, PROVIDEWALL CLEANOUT ATBASE OF RISER 2"ø BEDROOM 1/2"ø1/2"øWC-1 2"ø 3/4" CONDENSATE DRAIN WITH INDIRECT WASTE CONNECTION TO NEAREST SANITARY, VERIFYLOCATION AND ROUTING IN FIELD (TYPICAL) 3/4" CONDENSATE DRAIN WITHINDIRECT WASTE CONNECTION TO NEAREST SANITARY, VERIFY LOCATION AND ROUTING IN FIELD (TYPICAL) B-1 2"ø2"ø HP1 HP2 YCO FCO 4"ø FCO 1 A B 2 OA O1 O2 O3 O4 O5 BUILDING D BUILDING E UNIT D-3 (2 BEDROOM) UNIT D-4 (1 BEDROOM) UNIT E-2 (1 BEDROOM) UNIT E-3 (2 BEDROOM) 1 1/2"ø1 1/4"ø1/2"ø 1/2"ø1/2"ø 1 1/2"ø 1/2"ø1/2"ø1/2"ø 1" C&HW DN 3/4"ø1/2"ø1/2"ø 3/4"ø3/4"ø 1/2"ø DHWR 1"ø DHW1"ø DCW1/2"ø1/2"ø 1/2"ø1/2"ø1/2"ø 1 1/4"ø1"ø1/2"ø1/2"ø1"ø 1 1/4"ø1/2"ø1/2" CW&HW DN 1 1/4"ø 1/2"ø1/2"ø1/2"ø1/2"ø1/2"ø1/2"ø DCW DHWDHWR 1"ø DCW1 1/4"ø DHW1/2"ø DHWR 1 1/2" CW &1 1/4" HWDN 4"ø W DN 4"ø W DN 1/2"ø 1 1/2"ø W 1 1/2"ø 2"ø 4"ø 1 1/2" W DN 4" W DN 2" W DN 1 1/2" W DN LEVEL 2 1 1/2" W DN 4" W DN 3" V DN&UPTO 4" VTR 1 1/2"ø 1 1/2"ø 2"ø2"ø 1 1/2"ø 1 1/2"ø 2"ø 1 1/2"ø 2"ø2"ø 2 1/2"ø2 1/2"ø 4"ø 4" VENT TO VTR 2 1/2"ø 1 1/2"ø2"ø 2"ø HP2 HP2 3/4" CONDENSATE DRAIN WITHINDIRECT WASTE CONNECTION TO NEAREST SANITARY, VERIFY LOCATION AND ROUTING IN FIELD(TYPICAL) 3/4" CONDENSATE DRAIN WITHINDIRECT WASTE CONNECTIONTO NEAREST SANITARY, VERIFYLOCATION AND ROUTING IN FIELD(TYPICAL)HP1 HP1 1 1/2" Scale Date Drawn By Checked By Project Number UNCASVILLE, CT 1/8" = 1'-0" DE-PB1.1 PLUMBING PLAN BLDGS 'D' AND 'E'- LEVEL 1 AND 2 Dakota Partners, Inc. OXOBOXO LOFTS DA RS 11/01/2017 16-063 A B D E C F G H J K L M NORTH SITE KEY PLAN S-1 S-1 S-1 S-1 L-1 WC-1 B-1 B-1 WC-1 L-1 B-1 L-1 L-1 WC-1 WC-1 B-1 ELECTRICALROOM No.Description Date Revision 5 06/10/19 Arch Revisions 12/20/19 Addendum 8 11/15/19 PSK DE-PB1.1 12/31/19PSK DE-PB1.1 3" W TO BLDG 'C',SEE DRAWINGABC-PB1.SB FOR CONTINUATION 1 1/2" CW FROM BLDG 'C', SEE DRAWING ABC-PB1.SB FORCONTINUATION 1" CW MAKE UP TO BOILER LOOP LEVEL 1 INCOMING GAS SERVICEAND METER BY LOCALUTILITY COMPANY.SEE SITE UTILITY PLANFOR CONTINUATION GAS ON TOBELOW SLAB 3"ø FCO GG6" W FROM ABOVE, SEE LEVEL 2THIS SHEET FOR CONTINUATION. PROVIDE CLEANOUT AT BASE OF RISER GG B-1 B-1 SUMP 6" W TO BLDG 'G', SEEDRAWING G-PB1.1FOR CONTINUATION 1" CW FILL FOR SUMP TANK 1 1/4" GAS TO BLDG 'B', SEEDRAWING ABC-PB1.1 FORCONTINUATION CO GG 3"ø 3"ø 3"ø 2"3" CHEMICAL TREATMENTSYSTEMS FOR COOLINGTOWER AND SOURCE WATERLOOPS AS SPECIFIED AND DETAILED. COORDINATE EQUIPMENT, PUMP AND ACCESSORYSELECTION, INSTALLATION ANDOPERATION WITH COOLING TOWERMANUFACTURER 3/4"ø 1 1/4" CW UP 1 1/4"ø AREA RESERVED FOR SVE EQUIPMENT 2" V UP FD-1 HX-1 1 1/4"ø 1"ø FD-1 3/4" CONDENSATEDRAIN FROM ABOVE 1 1/4" GAS TO BLDG 'G', SEEDRAWIN G-PB1.1 FORCONTINUATION SAND FILTRATION EQUIPMENTWITH BACKWASH TANK ANDCONTROL PANEL AS SPECIFIED ANDDETAILED. COORDINATEEQUIPMENT, PUMP AND ACCESSORYSELECTION, INSTALLATION ANDOPERATION WITH COOLING TOWER MANUFACTURER, PROVIDE MINIMUM 3/4" CW CONNECTION AND 1 1/2"BACKWASH DRAIN PIPING TO FLOORDRAIN 1 1/4" GAS OUT TO GENERATORSEE SITE UTILITY PLAN FOR CONTINUATION 1 1/4" 3"2 1/2" 2" 1 1/2" 2 1/2" 1 1/4" GAS TO BOILER. PROVIDE PRESSURE REDUCING VALVEIN ACCECIBLE LOCATION.COORDINATE SIZE AND VENTINGREQUIREMENTS WITH BOILERMANUFACTURER (TYPICAL FOR 2) FD-1 CF-1 CF-2 1 1/2"ø1 1/4" LEVEL 2 G 2"ø 6" W FROM BLDGS 'B' 'D' & 'E', SEEDRAWING ABC-PB1.SB FORCONTINUATION G "GAS FROM BELOW,SEE LEVEL 1 THISSHEET FORCONTINUATION 2" GAS OUT TO GENERATOR, SEE SITE UTILITY PLAN FORCONTINUATION 6" W DN, SEE LEVEL 1 THIS SHEETFOR CONTINUATION HP9 3/4" CONDENSATEDRAIN DN 6" 2" V FROM BELOW TO 2" VTR ROOF CT-1 1 1/4" CW MAKE UPTO COOLING TOWER 1 1/4"ø Scale Date Drawn By Checked By Project Number UNCASVILLE, CT 1/8" = 1'-0" F-PB1.1 PLUMBING PLAN BUILDING 'F'- LEVEL 1, LEVEL 2 AND MEZZANINE Dakota Partners, Inc. OXOBOXO LOFTS DA RS 11/01/2017 16-063 A B D E C F G H J K L M NORTH SITE KEY PLAN No.Description Date Arch Revisions 12/20/19 PSK F-PB1.1 12/31/19PSK F-PB1.1 BUILDING H BUILDING G 4"ø UNIT G-5(2 BEDROOM)UNIT G-6 (1 BEDROOM)UNIT G-7 (1 BEDROOM) UNIT G-8 (1 BEDROOM)UNIT G-9(2 BEDROOM) UNIT G-4 (1 BEDROOM) UNIT G-3 (1 BEDROOM)UNIT G-2(1 BEDROOM) UNIT G-1(2 BEDROOM) 6"ø 3/4"ø 3/4"ø 1/2"ø 3/4"ø 3/4"ø 1/2"ø1/2"ø1/2"ø 1/2"ø3/4"ø 1"ø 6"ø 3/4"ø 1/2"ø S-1 S-1S-1 S-1 S-1 S-1S-1 S-1 S-1 WC-1 WC-1 WC-1 WC-1 WC-1 WC-1 WC-1 WC-1 WC-1 L-1 L-1 L-1 L-1 L-1 L-1 L-1 L-1 B-1 B-1B-1 B-1B-1 B-1 B-1 B-1B-1 1/2"ø1/2"ø 1/2"ø1/2"ø 1/2"ø1/2"ø 1/2"ø1/2"ø 4" VTR BUILDING K 6" SANITARY FROM BUILDING F, SEE DRAWINGF-PB1.1 FOR CONTINUATION SAN, CW, HW & HWR TO BUILDING, SEEDRAWING HK-PB1.1 FORCONTINUATION FCO 1/2"ø 1/2"ø 1/2"ø 1/2"ø 3/4"ø 1 1/2"ø 2"ø2"ø 3"ø 1 1/2"ø 1 1/2"ø 1 1/2"ø 1"ø 1"ø 3/4"ø3/4"ø 1/2"ø1/2"ø 3/4"ø SIMILAR TOUNIT G-6 SIMILAR TO UNIT G-7 1/2"ø1/2"ø 2"ø4"ø2"ø 3/4"ø 3/4"ø 2"ø 2 1/2"ø 3"ø L-1 4" VTR 4"ø 3/4"ø 2"ø2"ø 2"ø2"ø 1 1/2"ø 2"ø HP1 HP2 3/4" CONDENSATE DRAIN WITH INDIRECT WASTECONNECTION TO NEAREST SANITARY, VERIFYLOCATION AND ROUTING IN FIELD (TYPICAL) 3/4"ø HP1 HP1 HP1 2"ø 1 1/2"ø 2"ø 3/4"ø3/4"ø 1/2"ø1/2"ø 1 1/2"ø 2"ø 3/4"ø3/4"ø 1 1/2"ø 2"ø 2"ø 2"ø 1 1/2"ø 1/2"ø1/2"ø 3/4"ø3/4"ø 2"ø 2"ø 1 1/2"ø 3/4"ø3/4"ø 1 1/4"ø 1 1/2"ø 1 1/4" GAS UP ALONG WALL AND ACROSS ROOF OF BUILDING G ADJACENT TO HIGHER ROOFOF BUILDING H. PAINT, ATTACH AND INSTALLPER SPECIFICATIONS 1 1/4" GAS FROM BUILDING F, SEE DRAWINGF-PB1.1 FOR CONTINUATION GG1 1/2" GAS FROM ROOF INTOMECHANICAL ROOM OFBUILDING H. SEE DRAWINGHK-PB1.1 FOR CONTINUATION6"ø6"ø G FCO 1 1/2"ø HP2 HP1 HP1 HP1 Scale Date Drawn By Checked By Project Number UNCASVILLE, CT 1/8" = 1'-0" G-PB1.1 PLUMBING PLAN BUILDING G Dakota Partners, Inc. OXOBOXO LOFTS DA RS 11/01/2017 16-063 A B D E C F G H J K L M NORTH SITE KEY PLAN No.Description Date Arch Revisions 12/20/19 Addendum 8 11/15/19 PSK G-PB1.1 12/31/19PSK G-PB1.1 BFPBFP UNIT H-2 (2 BEDROOM) METERROOM LAUNDRY ROOMLOBBY BUILDING H (2) 300 GALLONINDIRECT HOT WATER STORAGE TANKS, SEE 11/P3.2 FORPIPING DIAGRAM GAS FIRED DOMESTIC HOT WATER BOILER UNIT H-1(1 BEDROOM) BOILER AND SPRINKLER ROOM JANITOR BUILDING J BUILDING K TMV1 B1 ET1 AS-1 3/4"ø DHWR 1"ø DHW 6"ø W 3/4"ø3/4"ø1 1/2"ø 1 1/4"ø UNIT K-2 (1 BEDROOM)UNIT K-4 (1 BEDROOM) UNIT K-1 (1 BEDROOM)UNIT K-3 (1 BEDROOM) P-1 P-2 3"ø 3/4"ø S-1 L-1 WC-11 1/4"ø2"øFD-13"ø B-1L-1 WC-1 B-1 3/4" H&CW TO WASHING MACHINESUPPLY MANIFOLD, PROVIDELAUNDRY MATE CONNECTION FOREACH UNIT AS SCHEDULED WMF-1 WMF-1 WMF-1 3/4"ø3/4"ø 3" STANDPIPE FORWASHING MACHINEINDIRECT DRAIN S-1 L-1 WC-1 B-1 1"ø DCW 2"ø L-1 L-1WC-1 WC-1 B-1 B-1 S-1 B-1 S-1 S-1 FCO 1 1/2"ø 2"ø2 1/2"ø 3"ø 4"ø 1 1/2"ø 2 1/2"ø 4" VTR 2 1/2"ø 4" VTR 2"ø 1 1/2"ø 2"ø SAN, CW, HW & HWR TOBUILDING G, SEE DRAWING G-PB1.1 FOR CONTINUATION SAN, CW, HW & HWR TOBUILDING J, SEE DRAWINGJ-PB1.1 FOR CONTINUATION SAN, CW, HW & HWRTO BUILDINGS L & M,SEE DRAWING LM-PB1.1 FOR CONTINUATION HP8 HP8 HP1 HP6 HP1 HP1 HP2 3/4" CONDENSATE DRAIN WITHINDIRECT WASTE CONNECTION TONEAREST SANITARY, VERIFY LOCATION AND ROUTING IN FIELD (TYPICAL) 1/2"ø1/2"ø 3/4"ø 3/4"ø 1/2"ø1/2"ø 3/4"ø3/4"ø 6"ø FCO 4"ø 4"ø FCO 1 1/4" GAS FROM ROOFABOVE, SEE DRAWINGG-PB1.1 FORCONTINUATION. PROVIDEPRESSURE REDUCINGVALVE IN ACCESSIBLELOCATION. COORDINATE SIZE AND VENTING REQUIREMENTS WITHBOILER MANUFACTURER 6"ø 1 1/2"ø 2 1/2"ø 1/2"ø1/2"ø1 1/2"ø HP1 1/2"ø1/2"ø 1 1/2"ø 1 1/2"ø S-1 1 1/2"ø1 1/2"ø 1 1/2"ø L-1 3/4"ø3/4"ø 3"ø WC-1 2"ø 1 1/2"ø 1 1/2"ø 3"ø SS-1 1 1/2"ø1 1/2"ø Scale Date Drawn By Checked By Project Number UNCASVILLE, CT 1/8" = 1'-0" HK-PB1.1 PLUMBING PLAN BLDGS 'H' & 'K'- LEVEL 1 Dakota Partners, Inc. OXOBOXO LOFTS DA RS 11/01/2017 16-063 A B D E C F G H J K L M NORTH SITE KEY PLAN No.Description Date Arch Revisions 12/20/19 Addendum 8 11/15/19 PSK HK-PB1.1 PSK-HK-PB1.1 12/31/19 BUILDING J UNIT J-8(2 BEDROOM) UNIT J-7 (1 BEDROOM) UNIT J-6 (2 BEDROOM) UNIT J-3 (2 BEDROOM) UNIT J-2 (2 BEDROOM)UNIT J-1 (2 BEDROOM) UNIT J-5 (2 BEDROOM) UNIT J-4 (2 BEDROOM) FCO 3/4"ø 1"ø 3/4"ø 1"ø 3/4"ø3/4"ø 3/4"ø3/4"ø 3/4"ø3/4"ø 3/4"ø3/4"ø 3/4"ø3/4"ø 1/2"ø 1/2"ø 1/2"ø 1/2"ø L-1 B-1WC-1 L-1 B-1 WC-1 S-1 S-1 L-1 L-1 HP2 HP1WC-2 WC-1B-1 B-1 BUILDING H S-1 S-1 S-1 S-1 S-1 S-14" VTR 3/4" CONDENSATE DRAIN WITHINDIRECT WASTE CONNECTION TO NEAREST SANITARY, VERIFY LOCATION AND ROUTING IN FIELD (TYPICAL) HP3 HP1 HP3 L-1 WC-1B-1 L-1WC-1B-1 B-1 WC-1 WC-1WC-1 WC-1B-1B-1 B-1 L-1 L-1 L-1 L-1 4" VTR 4" VTR 2"ø 2"ø 3"ø 4" VTR 4" VTR 1/2"ø1/2"ø 1 1/2"ø 3"ø 3/4"ø 3/4"ø3/4"ø 3"ø 1/2"ø1/2"ø 1"ø 3/4"ø 1/2"ø 1/2"ø1/2"ø 1/2"ø1/2"ø 2"ø 1"ø 1/2"ø 1/2"ø1/2"ø 1"ø 3/4"ø 1"ø 3/4"ø 2"ø 2"ø 3"ø 4"ø 2"ø 1/2"ø1/2"ø 4"ø 1 1/2"ø1/2"ø1/2"ø1/2"ø1/2"ø1/2"ø 1/2"ø1/2"ø 3"ø 4"ø 1 1/2"ø 2"ø 4"ø 2"ø 3"ø3"ø 2"ø 4"ø 2"ø 2"ø2 1/2"ø2 1/2"ø 1 1/2"ø1 1/2"ø 3"ø3"ø 1 1/2"ø 2"ø 1/2"ø 1 1/2"ø 4"ø 1 1/2"ø 2"ø 2"ø 4"ø 1 1/2"ø FCO 1 1/2"ø 2"ø2"ø 2"ø 4"ø 3"ø3"ø 2"ø4"ø 1 1/2"ø 3"ø3"ø2 1/2"ø2 1/2"ø 1 1/2"ø NEW SEWAGE EJECTOR PITWITH DUPLEX PUMP SET.PROVIDE ACCESSIBLE CHECKVALVE ON DISCHARGE CONNECTION TO GRAVITY SANITARY AS REQUIREDAND VENT CONNECTIONAS SHOWN. "HOMA" GRINDER SERIES#GRP16/3, OR APPROVED EQUAL.1.5HP, 208V, 3 PH, 45 GPM, 9 FT. HD.FIBERGLASS BASIN WITH ACCESSIBLE COVER, DUPLEX CONTROL PANEL 2"ø 1 1/2"ø 2"ø FCO HP2 HP2 4"ø HP2 2"ø Scale Date Drawn By Checked By Project Number UNCASVILLE, CT 1/8" = 1'-0" J-PB1.1 PLUMBING PLAN BUILDING 'J'- LEVEL 1 Dakota Partners, Inc. OXOBOXO LOFTS DA RS 11/01/2017 16-063 A B D E C F G H J K L M NORTH SITE KEY PLAN No.Description Date Arch Revisions 12/20/19 Addendum 8 11/15/19 PSK J-PB1.1 PSK J-PB1.1 12/31/19 STORAGE 3 3"ø 3/4"ø 3/4"ø1/2"ø1/2"ø 3/4"ø3/4"ø 3"ø 3"ø 3"ø 2 1/2"ø2"ø2"ø1 1/4"ø1 1/4"ø1"ø 1/2"ø 4"ø 6"ø 6"ø 3/4"ø 3/4"ø 3/4"ø3/4"ø1/2"ø3/4"ø 3/4"ø3/4"ø 1"ø 1"ø 3/4"ø 1"ø 6"ø 3"ø 3/4"ø 3/4"ø 3/4"øB-1 WC-1 L-1 S-1 6" SANITARY, 1 1/4" HW AND 3/4" HWR FROM BUILDINGK. SEE DRAWINGHK-PB 1.1 FORCONTINUATION 2" CW FROM BUILDING K.SEE DRAWING HK-PB1.1FOR CONTINUATION 6" SANITARY OUT,WITH ACCESSIBLE BACKFLOWVALVE. SEE SITE UTILITY PLANFOR CONTINUATION 3" CW SERVICE IN, SEE SITE UTILITY PLANFOR CONTINUATIONFOR DOMESTIC WATERSERVICE INSTALLATIONSEE 7/P3.1 FIRE PROTECTIONSERVICE IN WITHBACKFLOW PREVENTER,SEE DRAWING LM-FP1.1 UNIT M-6(2 BEDROOMS) UNIT M-7 (2 BEDROOMS) UNIT M-8 (2 BEDROOMS) UNIT M-9(2 BEDROOMS) UNIT M-10(2 BEDROOMS) UNIT M-11 (2 BEDROOMS) UNIT M-5(2 BEDROOMS) UNIT M-4(2 BEDROOMS) UNIT M-3(2 BEDROOMS) UNIT M-2 (2 BEDROOMS) UNIT M-1(1 BEDROOM) BUILDING M L-1 WC-1B-1B-1WC-1 L-1 S-1S-1 L-1WC-1B-1B-1WC-1L-1 S-1 S-1 L-1 S-1 WC-1B-1 S-1 L-1 WC-1 B-1 S-1 L-1 WC-1 B-1 S-1 S-1 S-1 L-1 L-1 L-1 L-1 B-1 B-1 B-1B-1 WC-1 WC-1 WC-1WC-1 HP2 HP1 HP1 HP1 HP1 HP2 HP2 2"ø 1/2"ø 1/2"ø 4" VTR 4" VTR 1 1/2"ø 1/2"ø1/2"ø 2"ø 3/4"ø3/4"ø 1/2"ø 2"ø 4"ø2"ø 3"ø 2"ø 1/2"ø1/2"ø 1/2"ø1/2"ø 2"ø4"ø 2"ø 2"ø 4"ø2"ø 3/4"ø 1/2"ø1/2"ø 1/2"ø1/2"ø 1/2"ø 1/2"ø1/2"ø 6"ø 1 1/2"1 1/2" 2"1 1/2"2" 4" VTR 2" 2 1/2" 4"ø 1 1/2" 1 1/2" 4" VTR 1 1/2"1/2"ø1/2"ø 2" 2" 1 1/2"ø 2"ø 1 1/2" 1 1/2" 4"ø4"ø 1/2"ø 2"ø 3/4" CONDENSATE DRAIN WITHINDIRECT WASTE CONNECTIONTO NEAREST SANITARY, VERIFYLOCATION AND ROUTING IN FIELD (TYPICAL) 6"ø 2"ø 1 1/2"ø 6"ø 1 1/2" 2" 4"ø 2"ø HP-2 HP1 4" HP-1 HP2 HP2 HP1 HP1 FCO Scale Date Drawn By Checked By Project Number UNCASVILLE, CT 1/8" = 1'-0" LM-PB1.1 PLUMBING PLAN BUILDINGS L AND M LEVEL 1 Dakota Partners, Inc. OXOBOXO LOFTS DA RS 11/01/2017 16-063 A B D E C F G H J K L M NORTH SITE KEY PLAN No.Description Date Arch Revisions 12/20/19 Addendum 8 11/15/19 PSK LM-PB1.1 PSK-LM-PB1.1 12/31/19