HomeMy WebLinkAboutM_16066_42PINKROW_R19OA
WA
L2.2
L2.A
L2.B
L2.C
L2.D
L2.E
L2.F
L2.G
L2.H
L2.J
L2.K
L2.M
L2.N
L2.1
O1 O2 O3 O4 O5
W1 W2 W3 W4 W5
W6
W7 W8 W9
L2.L
BUILDING D
BUILDING B
BUILDING C
BUILDING G
BUILDING A
UNIT A-1
(2 BEDROOM)
UNIT A-2
(1 BEDROOM)
UNIT B-3
(1 BEDROOM)
TYPE 'A'
UNIT B-4
(2 BEDROOM)
UNIT B-5
(1 BEDROOM)
UNIT B-6
(1 BEDROOM)
UNIT B-7
(STUDIO)
UNIT A-3
(2 BEDROOM)
HP1
HP1
T
HP1
T
HP1
T
HP1
A-125
B-150
E-450
C-250
10"x4"
12"x6"
12x12 SAPLENUM
B-150
T
HP1
T
HP1
T HP1
8"ø
T
HP1
6"x6"
D-350
10"x8"HP1
12x12 SAPLENUM
12x12 SAPLENUM
R6-600
B-200
T
E1-20
E1-20
E1-20
E1-20 VD
VD
4"x4"4"x4"4"ø4"ø6X6 EA DUCT UP,4X4 EA DN
OA TO HP1
OA TO HP1
E1-20
E1-20
E1-20
E1-20
E1-20
VD
VD
VD
VD
VD
VD 4"ø4"ø4"ø
4"x4"4"ø
4"ø
F-75
F-75
G-150
R5-290
8X8 RA UP6X6 EA DUCT DN & 6X4 EA DUCT UP,PROVIDE FD AT DECKS ABOVE & BELOW
6x6 OA DUCT DN AND 4X6 DUCT UP,
PROVIDE FD AT DECKS ABOVE & BELOW
6x6 EA DN AND 6X4 EA UP,PROVIDE FD AT DECKS ABOVE & BELOW
E1-20E1-20
E1-20
4"ø4"x4"4"ø4"ø
8"ø10"ø10x10 SA DUCT UP,8x6 SA DUCT DN
R4-175
B-200
6"x4"
6X6 OA DUCT UP,4X4 OA DN
R6-600
R6-600 4"ø4"x4"R6-600
4"ø4"x4"R-600
4"ø
FD
FD
EWH-3
4"x4"
D-350
10X8 SA DUCT DN & 8X8 SA DUCT UP,PROVIDE FD AT DECKS ABOVE & BELOW
AXG
AXG
AXG
AXG
AXG
AXG
AXG
AXG
AXG
12"x6" AIR TRANSFER GRILLEASSEMBLY (AXG). PROVIDE 12"X3"TRANSFER DUCT IN WALL WITHHIGH INLET GRILLE AND LOWOUTLET GRILLE (TYPICAL
FOR ALL)
6"x4"
8X8 EA DUCT UP,
4X4 EA DN
EI-20
4"x4"
12"X6" AIR TRANSFER GRILLE
ASSEMBLY (AXG). PROVIDE 12"X3"TRANSFER DUCT IN WALL WITHHIGH INLET GRILLE AND LOWOUTLET GRILLE (TYPICAL FOR ALL)
C-300
A-125
A-300
A-100
A-100
B-150
HP1
D-400
12x12 SAPLENUM
HP1
A-125
12X12 SA PLENUM
E-450
R6-600
HP1
4"x4"
4"x4"
E1-20
HP1
R6-600B-175
4X4 OA DUCT UP, 6X4 OADUCT DN, PROVIDE FDAT DECKS ABOVE & BELOW
E1-20HP1
AXG
10X8 RA DUCT DN, 8X6 RADUCT UP, PROVIDE FDAT DECKS ABOVE & BELOW
HP1
R6-600
D-350
6x6 OA DUCT UP,6X4 OA DUCT DN
E1-20
4X4 OA FROM BELOW
Scale
Date
Drawn By
Checked By
Project Number
UNCASVILLE, CT
1/8" = 1'-0"
ABC-MD1.1
MECHANICAL
DUCTWORK PLAN
BLDGS 'A', 'B', 'C'-
LEVEL 1
Dakota
Partners, Inc.
OXOBOXO
LOFTS
DA
RS
11/01/2017
16-063
A
B
D E
C F
G H
J
K
L M
NORTH
SITE KEY PLAN
No.Description Date
8 Addendum 8 11/5/19
8
MSK ABC-MD1.1 12/31/19
MSK ABC-MD1.1
OA
WA
L2.2
L2.A
L2.B
L2.C
L2.D
L2.E
L2.F
L2.G
L2.H
L2.J
L2.K
L2.M
L2.N
L2.1
O1 O2 O3 O4 O5
W1 W2 W3 W4 W5
W6
W7 W8 W9
L2.L
UNIT B-8
(1 BEDROOM)
TYPE A
UNIT B-9
(2 BEDROOM)
UNIT B-10
(1 BEDROOM)
UNIT B-11
(1 BEDROOM)
UNIT B-12
(1 BEDROOM)
BUILDING B BUILDING C
BUILDING A
BUILDING G
BUILDING D
F-75
F-75
G-150
HP1
A-125
HP1
12x12 SA
PLENUM
T
HP-6
E1-20
E1-204"x4"4"ø8x6 OA DUCT UP,6X6 OA DUCT DN
HP1B-150 E-4506"x6"
HP1
12x12 SAPLENUM
E1-20
E1-20 VD
VD 4"øE1-20
E1-20
E1-20
VD
VD
VD
4"ø
4"ø
E-450
T
HP1
E1-20
E1-20
VD
VD4"ø4"ø
R5-290
10x10 RA DUCT UP8x8 RA DUCT DN
T
8x6 EA DUCT UP,
8x6 EA DUCT DN
8x6 EA DUCT UP6x6 EA DUCT DN
12x12 SA DUCT UP10x10 SA DUCT DN 8"ø10"øOA CONNECTION TO HP1(TYPICAL)
8x6 OA DUCT UP,6x6 OA DUCT DN
D-350
R6-600
6"x4"4"x4"4"ø
R6-600
4"ø
4"x4"
4"x4"
FD
FD
FD
FD
T
HP1
T
HP1
AXG
AXGAXG
AXG
AXG
AXG
EWH-4
12"X 6" AIR TRANSFER GRILLEASSEMBLY (AXG). PROVIDE12"X3" TRANSFER DUCT INWALL WITH HIGH INLET
GRILLE AND LOW OUTLET
GRILLE (TYPICAL FOR ALL)
B-150
A-125
D-400
T
FD
FD
12X12 SA PLENUM
HP1
R6-600
R6-600HP1
B-200
R6-600
E-450
B-150
HP1
8" DRYER EXHAUST
UP TO BOOSTER FANON TOP FLOOR
4"ø
4"ø 6"ø6"ø
VD
E1-20
FD
Scale
Date
Drawn By
Checked By
Project Number
UNCASVILLE, CT
1/8" = 1'-0"
ABC-MD1.2
MECHANICAL
DUCTWORK PLAN
BLDGS 'A', 'B', 'C'-
LEVEL 2
Dakota
Partners, Inc.
OXOBOXO
LOFTS
DA
RS
11/01/2017
16-063
A
B
D E
C F
G H
J
K
L M
NORTH
SITE KEY PLAN
No.Description Date
8 Addendum 8 11/5/19
8
MSK ABC-MD1.2 12/31/19
MSK ABC-MD1.2
4" DRYER EXHAUST
(TYPICAL FOR 4)
WA
L2.2
L2.A
L2.B
L2.C
L2.D
L2.E
L2.F
L2.G
L2.H
L2.J
L2.K
L2.M
L2.N
L2.1
O1 O2 O3 O4 O5
W1 W2 W3 W4 W5
W6
W7 W8 W9
L2.L
BUILDING G
BUILDING D
BUILDING B
(LEVEL 3)BUILDING C
BUILDING A
UNIT A-4
(1 BEDROOM)
H.C.
UNIT A-5(1 BEDROOM)
UNIT A-6
(2 BEDROOM)
H.C.
UNIT B-13
(1 BEDROOM)
TYPE A
UNIT B-14
(2 BEDROOM)
UNIT B-15
(1 BEDROOM)
UNIT B-16
(1 BEDROOM)
UNIT B-17(1 BEDROOM)
R6-600
THP1
T
HP1
T
HP1
4"x4"4"ø4"øT
T
6"x6"
4"ø
4"ø
T4"ø4"ø4"ø
HP2
C-300
B-150
12x12 SAPLENUM
T
HP2
E1-20
E1-20
E1-20
VD
VD
VD
R5-290
10x10 RA DUCT DN
12x12 RA DUCT UP
F-75
G-150
HP1
B-150 E-450
T HP1
12x12 SAPLENUM
E1-20
VD
E1-20
E1-20
E1-20
VD
VD
VD
F-75
HP1
12x12 SAPLENUM
B-200
T
E1-20
E1-20
HP1
E1-20 VD
VD
8x8 EA DUCT UP8x6 EA DUCT DN
8x10 EA DUCT UP,
8x8 EA DUCT DN
E1-20
E1-20A-100
E1-20
E1-20
E1-20
4"ø
4"x4"4"ø4"ø4"x4"4"ø
8"ø10"ø14x12 SA DUCTUP, 12x12 SADUCT DN,PROVIDE FIREDAMPER ATDECK
R4-175
B-2004x4 OA DUCT DN
6x4 EA DUCT DN4"ø6X4 EADUCT DN
8x8 OA DUCT UP,8x6 OA DUCT DN
OA CONNECTION TO HP1(TYPICAL)
4"ø
HP1
R6-600D-3506"x4"4"x4"4"ø
R6-600 4"ø4"x4"R6-600
R7-800
B-150
4"x4"4"x4"
4"ø
FD
FD
FD
FD
FD
T HP-1
8X4 SA DUCT DN
AXG
AXGAXG
AXG
AXG
AXG
AXG
AXG
AXG
AXG
8X8 OA DUCT UP,8X6 OA DN
8X10 EA DUCTUP, 8X6 EA DN
A-125
C-275
R6-600
A-125
A-125
E-450
12X12 SA PLENUM C-250
A-125
D-350 4"x4"R6-600
C-300
B-200
R6-600
HP1
4X4 OA DUCT DN
EI-20
B-150E-450
R6-600
8X6 RA DN
HP1
A-100
6"ø
A-125
HP1
HP1
8" DRYER EXHAUST UP &DN, ENCLOSURE BY ARCHTECT
HP1
Scale
Date
Drawn By
Checked By
Project Number
UNCASVILLE, CT
1/8" = 1'-0"
ABC-MD1.3
MECHANICAL
DUCTWORK PLAN
BLDGS 'A', 'B', 'C'-
LEVEL 3
Dakota
Partners, Inc.
OXOBOXO
LOFTS
DA
RS
11/01/2017
16-063
A
B
D E
C F
G H
J
K
L M
NORTH
SITE KEY PLAN
No.Description Date
7 Permit ReviewComments 08/05/2019
8 Addendum 8 11/5/19
8
MSK ABC-MD1.3 12/31/19
MSK ABC-MD1.3
WA
L2.2
L2.A
L2.B
L2.C
L2.D
L2.E
L2.F
L2.G
L2.H
L2.J
L2.K
L2.M
L2.N
L2.1
W1 W2 W3 W4 W5
W6
W7 W8 W9
L2.L
BUILDING B
BUILDING A
UNIT B-18
(1 BEDROOM)
UNIT B-19
(2 BEDROOM)
UNIT B-20
(1 BEDROOM)
UNIT B-21
(1 BEDROOM)
UNIT B-22
(1 BEDROOM)
ATTIC SPACE
F-75
10"x4"4"x4"4"ø4"øT
6"x6"
4"ø
4"ø
T4"ø4"ø4"ø
HP2
C-250
C-300
12x12 SAPLENUM
B-150
12x12 SAPLENUM
T
HP2
E1-20
E1-20
E1-20
VD
VD
VD
R5-290
14x14 RA DUCT UP,12x12 RA DUCT DN
8X8 OA DUCT DN,
8X10 OA DUCT UP
B-150
HP1
B-150 E-450
HP1
12x12 SAPLENUM
E1-20
VD
VD
E1-20
E1-20
E1-20
VD
VD
VD
F-75
HP1
A-125A-125
12x12 SA
PLENUM
B-200
T
E1-20
E1-20
OA TO HP1(TYPYCAL)
HP1
E1-20 VD
VD
T
10x10 EA DUCT UP8x8 EA DUCT DN
HP110"ø8"ø14x14 SA UP,14x12 SA DN.PROVIDE FIREDAMPER AT DECK
8x8 OA DUCT UP,
8x10 OA DUCT DN
FD
FD
6"x4"
4"ø
4"x4"R6-600
RA-600 4"øFD
FD
4"x4"
T
HP1
R7-800
4"x4"E-450
AXG
AXG AXG
AXG
AXG
AXG
8x6 OA DUCT DN8X8 OA DUCT UP
D-350
10x10 EA DUCT UP,
8x10 EA DUCT DN
B-150
4"x4"R6-600
A-125
C-275
HP1
A-100
4"ø R6-600
HP1R6-600
6"ø
8" DRYER EXHUST UP & DNENCLOSURE BY ARCHITECT
Scale
Date
Drawn By
Checked By
Project Number
UNCASVILLE, CT
1/8" = 1'-0"
ABC-MD1.4
MECHANICAL
DUCTWORK PLAN
BLDGS 'A', 'B', 'C'-
LEVEL 4
Dakota
Partners, Inc.
OXOBOXO
LOFTS
DA
RS
11/01/2017
16-063
A
B
D E
C F
G H
J
K
L M
NORTH
SITE KEY PLAN
No.Description Date
MSK ABC-MD1.4 12/31/19
MSK ABC-MD1.4
WA
L2.2
L2.A
L2.B
L2.C
L2.D
L2.E
L2.F
L2.G
L2.H
L2.J
L2.K
L2.M
L2.N
L2.1
W1 W2 W3 W4 W5
W6
W7 W8 W9
L2.L
VD
EA0A12"x12"12"x12"8"x10"12"x12"14"x14"ERV-214x14 RA DUCT DN
HP4
14x14 SA DN
14"x14"8"x8"8"x10"8"x8"
10x10 EA DUCT DN
8x8 OADUCT DN
12"x10"DRYER BOOSTER FAN.COORDINATE, SELECTION,SIZING, INSTALLATION
AND CONTROLWITH DRYER
MANUFACTURER
8x10 EA DUCT DN
8x8 OA DUCT DN
SA RA
EA0A
FD
FDFD
FD
FDFD
8" DRYER EXHAUST
FROM LAUNDRY ROOM
8" DRYER EXHAUST TOWEATHERPROOFROOF CAP
FDFD FD
Scale
Date
Drawn By
Checked By
Project Number
UNCASVILLE, CT
1/8" = 1'-0"
ABC-MD1.5
MECHANICAL
DUCTWORK PLAN
BLDGS 'A','B','C''-
ATTIC
Dakota
Partners, Inc.
OXOBOXO
LOFTS
PC
RS
11/01/2017
16-063
A
B
D E
C F
G H
J
K
L M
NORTH
SITE KEY PLAN
No.Description Date
MSK ABC-MD1.5 12/31/19
MSK ABC-MD1.5
OA
WA
L2.2
L2.A
L2.B
L2.C
L2.D
L2.E
L2.F
L2.H
L2.J
L2.K
L2.M
L2.N
L2.1
O1 O2 O3 O4 O5
W1 W2 W3 W4 W5
W6
W7 W8 W9
L2.L
UNIT B-1(2 BEDROOM)
TYPE A
UNIT B-2
(2 BEDROOM)
UNIT C-3
(2 BEDROOM)TYPE A
UNIT C-4(2 BEDROOM)
TYPE A
ELEVATOR
BUILDING B
BUILDING CBUILDING A
BUILDING G
BUILDING D
BUILDING F
HP2
B-150
T HP2
E-500
T
B-150B-150
HP-7
VD4"x4"6x4 OA DUCT UPPROVIDE FD AT DECK
4x4 EA DUCT UP
PROVIDE FDAT DECK
6"x4"6"x6"
6"x6"4"øE1-20
VD
6x4OA TO HP2
T
HP2
4x4 EA DUCT UP
8x6 SADUCT UPPROVIDE FD
AT DECK
B-160
E1-20 4"øR7-800
R7-800
B-150
B-150
R7-800
T
EF-1
EF-1
EF-1
EWH-2
EF1
ERV-1
EA
0A
6x6 EA DUCT UP
8" DIAWEATHERPROOF
WALL CAP
(TYPICAL FOR 2)8"x8"8"x8"8"x8"
8"x8"
10"x8"
HP-5
10"x8"4"x4"6X6 OA DUCT UP,
6X6 EA DUCT UP
10X8 RA DUCT UP
10X8 SA DUCT UP
AXG
AXG
AXG
AXG
AXGAXG
AXG
4"ø
4"ø
4"ø
4"ø
10"x8"
VD
4" EA TO WEATHERPROOFWALL CAP (TYPICAL FOR 4)
12X6" AIR TRANSFER GRILLE ASSEMBLY(AXG). PROVIDE 12"X3" TRANSFER DUCT
IN WALL WITH HIGH INLET GRILLE AND
LOW OUTLET GRILLE (TYPICAL FOR ALL)
B-150C-250
R7-800
HP2 8"x8"
16"x10"
10"x8"
AXG
6x4 OA DUCT UP
6"x4"10"øE1-20
6"ø
6X4 OA DUCT UP
HP2
C-250
HP2
8"ø 4"x4"VD
6X4 OADN TOHP2
4"x4"
E1-20
4"x4"
4X4 OA UP
B-150
D-375
A-125
HP2
Scale
Date
Drawn By
Checked By
Project Number
UNCASVILLE, CT
1/8" = 1'-0"
ABC-MD1.B
MECHANICAL
DUCTWORK PLAN
BLDG A-CRAWL SPACE
BLDG B - LEVEL B
BLDG C - LEVEL 2
Dakota
Partners, Inc.
OXOBOXO
LOFTS
DA
RS
11/01/2017
16-063
A
B
D E
C F
G H
J
K
L M
NORTH
SITE KEY PLAN
No.Description Date
8 Addendum 8 11/5/19
8
8
12/31/19MSK ABC-MD1.B
MSK ABC-MD1.B
WA
L2.2
L2.A
L2.B
L2.C
L2.D
L2.E
L2.F
L2.G
L2.H
L2.J
L2.K
L2.M
L2.N
L2.1
L2.L
UNIT C-1(2 BEDROOM)
UNIT C-2
(2 BEDROOM)
STAIR 2
ELECTRICAL
METERROOM
MAINTENANCE
ROOM
BUILDING B
BUILDING C
BUILDING A
(ABOVE)
BUILDING D
BUILDING G
T HP2
T
HP2
EF-1
EWH-1
EF-1
EF-1
EF-1
4" EA TO WEATHERPROOF
WALL CAP (TYPICAL FOR 4)
DOMESTIC HOT WATER BOILER
6" FLUE VENT AND 8" COMBUSTION AIR
INTAKE
AXG
AXGAXG
B-1
6" FLUE EXHAUST AND 8"COMBUSTION AIR INTAKE TOWALL TERMINAL KIT. SIZE,ROUTING, LOCATION ANDINSTALLATION AS PERMANUFACTURER'SRECOMMENDATIONS (TYPICAL)
8"ø 4"ø12X6" AIR TRANSFERGRILLE ASSEMBLY(AXG). PROVIDE 12"X3"TRANSFER DUCT INWALL WITH HIGHINLET GRILLE ANDLOW OUTLET GRILLE
(TYPICAL FOR ALL)
4"ø4"ø
4"ø
C-250 B-150
C-250 B-150
8"x8"
HP2
R7-800
AXG
B-150
HP2
B-150C-250
10"x10"
C-250 10"x8"R7-800
EUH-1
T
EUH-1
6"ø
8"ø
Scale
Date
Drawn By
Checked By
Project Number
UNCASVILLE, CT
1/8" = 1'-0"
ABC-MD1.SB
MECHANICAL
DUCTWORK PLAN
BLDG 'B'-LEVEL SB
BLDG 'C'- LEVEL 1
Dakota
Partners, Inc.
OXOBOXO
LOFTS
DA
RS
11/01/2017
16-063
A
B
D E
C F
G H
J
K
L M
NORTH
SITE KEY PLAN
No.Description Date
8 Addendum 8 11/5/19
8
MSK ABC-MD1.SB 12/31/19
MSK ABC-MD1.SB
OA
WA
L2.2
L2.A
L2.B
L2.C
L2.D
L2.E
L2.F
L2.G
L2.H
L2.J
L2.K
L2.M
L2.N
L2.1
O1 O2 O3 O4 O5
W1 W2 W3 W4 W5
W6
W7 W8 W9
L2.L
BUILDING D
BUILDING B
BUILDING C
BUILDING G
BUILDING A
UNIT A-1
(2 BEDROOM)
UNIT A-2(1 BEDROOM)
UNIT B-3(1 BEDROOM)
TYPE 'A'
UNIT B-4(2 BEDROOM)
UNIT B-5
(1 BEDROOM)
UNIT B-6
(1 BEDROOM)
UNIT B-7
(STUDIO)
UNIT A-2(2 BEDROOM)
HP-6
HP1
HP1
HP1
1 1/2" SWS&R UP1 1/2" SWS&R DN
HP1
HP1
1" SWS&R 1 1/4" SWS&R 1 1/2" SWS&R
2" SWS&R
1 1/4" SWS&R UP
1 1/2" SWS&R DN
1 1/4" SWS&R UP
1" SWS&R UP1 1/4" SWS&R DN
3" SWS&R DN
3/4" SWS & R DOWN
TO CRAWL SPACE
HP1
HP1
3/4"ø SWS3/4"ø SWR3/4"ø SWR
3/4"ø SWS
3/4"ø SWR
3/4"ø SWS
1 1/4"ø SWR
1 1/4"ø SWS
1 1/4" SWS&R UP,
1 1/2" SWS&R DN
HP1
3/4"ø SWR
3/4"ø SWS1"ø SWS1"ø SWR8
3/4"ø SWS
3/4"ø SWR
ELEVATOR2 1/2"ø SWS2 1/2"ø SWR3"ø SWS3"ø SWR3/4"ø SWR
3/4"ø SWS
3/4" SWS&R UP
3/4" SWS&R UP 1"ø SWR1"ø SWS1"ø SWR1"ø SWSPROVIDE CIRCUIT SETTERAT END OF LOOP BRANCHSIZED FOR PROPER GMP
PROVIDE CIRCUIT SETTER
AT END OF LOOP BRANCH
SIZED FOR PROPER GMP
Scale
Date
Drawn By
Checked By
Project Number
UNCASVILLE, CT
1/8" = 1'-0"
ABC-MP1.1
MECHANICAL PIPING
PLAN BLDG 'B', 'C'-
LEVEL 1
Dakota
Partners, Inc.
OXOBOXO
LOFTS
DA
RS
11/01/2017
16-063
A
B
D E
C F
G H
J
K
L M
NORTH
SITE KEY PLAN
No.Description Date
8 Addendum 8 11/5/19
MSK ABC-MP1.1 12/31/19
MSK ABC-MP1.1
OA
WA
L2.2
L2.A
L2.B
L2.C
L2.D
L2.E
L2.F
L2.G
L2.H
L2.J
L2.K
L2.M
L2.N
L2.1
O1 O2 O3 O4 O5
W1 W2 W3 W4 W5
W6
W7 W8 W9
L2.L
UNIT B-8
(1 BEDROOM)TYPE A
UNIT B-9(2 BEDROOM)
UNIT B-10
(1 BEDROOM)
UNIT B-11
(1 BEDROOM)
UNIT B-12
(1 BEDROOM)
BUILDING B
BUILDING C
BUILDING A
BUILDING G
BUILDING D
HP1
HP1
HP1
2"SWS&R
HP1
1" SWS&R
1" SWS&R UP,1 1/4" SWS&R DW
3/4"
3/4"3/4"
1 1/4" SWS&R UP,
1 1/2" SWS&R DN
1" SWS&R UP,
1 1/4" SWS&R DN
3/4"
1" SWS&R UP,
1 1/4" SWS&R DN
1 1/4" SWS&R UP,
2" SWS&R DN
HP1
3/4"ELEVATOR
Scale
Date
Drawn By
Checked By
Project Number
UNCASVILLE, CT
1/8" = 1'-0"
ABC-MP1.2
MECHANICAL PIPING
PLAN BLDGS 'B', 'C'-
LEVEL 2
Dakota
Partners, Inc.
OXOBOXO
LOFTS
DA
RS
11/01/2017
16-063
A
B
D E
C F
G H
J
K
L M
NORTH
SITE KEY PLAN
No.Description Date
8 Addendum 8 11/5/19
8
MSK ABC-MP1.2 12/31/19
MSK ABC-MP1.2
WA
L2.2
L2.A
L2.B
L2.C
L2.D
L2.E
L2.F
L2.G
L2.H
L2.J
L2.K
L2.M
L2.N
L2.1
O1 O2 O3 O4 O5
W1 W2 W3 W4 W5
W6
W7 W8 W9
L2.L
BUILDING G
BUILDING D
BUILDING B
BUILDING C
BUILDING A
UNIT A-4
(1 BEDROOM)
H.C.UNIT A-5
(1 BEDROOM)
UNIT A-6
(2 BEDROOM)H.C.
UNIT B-13
(1 BEDROOM)
TYPE A
UNIT B-14
(2 BEDROOM)
UNIT B-15
(1 BEDROOM)
UNIT B-16
(1 BEDROOM)
UNIT B-17
(1 BEDROOM)
HP1
HP1
HP2
3/4" SWS&RUP, 1" SWS&RDN
HP1
3/4" SWS&R UP,1" SWS&R DN
1 1/4" SWS&R UP,1 1/4" SWS&R DN
3/4" SWS&R UP
1" SWS&R UP1 1/4" SWS&R DN
1"ø SWR
1" SWS&RSWS&R DNHP1HP1
HP1
3/4" SWS&R DN
3/4"ø SWS
3/4"ø SWR
HP1
3/4"ø SWS
3/4"ø SWR
3/4"ø SWR
3/4"ø SWS
Scale
Date
Drawn By
Checked By
Project Number
UNCASVILLE, CT
1/8" = 1'-0"
ABC-MP1.3
MECHANICAL PIPING
PLAN BLDGS 'B', 'C'-
LEVEL 3
Dakota
Partners, Inc.
OXOBOXO
LOFTS
PC
RS
11/01/2017
16-063
A
B
D E
C F
G H
J
K
L M
NORTH
SITE KEY PLAN
No.Description Date
8 Addendum 8 11/5/19
8
MSK ABC-MP1.3 12/31/19
MSK ABC-MP1.3
WA
L2.2
L2.A
L2.B
L2.C
L2.D
L2.E
L2.F
L2.G
L2.H
L2.J
L2.K
L2.M
L2.N
L2.1
W1 W2 W3 W4 W5
W6
W7 W8 W9
L2.L
BUILDING B
BUILDING A
UNIT B-18(1 BEDROOM)
UNIT B-19(2 BEDROOM)
UNIT B-20
(1 BEDROOM)
UNIT B-21
(1 BEDROOM)
UNIT B-22(1 BEDROOM)
ATTIC SPACE
HP1
HP1
HP1
HP1
HP2
1" SWS&R UP,1 1/4" SWS&R DN
1" SWS&R DN
3/4"SWS&R DN
3/4"SWS&R DN
3/4"SWS&R DN
ELEVATOR
ATTIC
3/4"
3/4"ø SWR
3/4"ø SWS
WA
L2.2
L2.A
L2.B
L2.C
L2.D
L2.E
L2.F
L2.G
L2.H
L2.J
L2.K
L2.M
L2.N
L2.1
L2.L
1" SWS&R DN HP4
Scale
Date
Drawn By
Checked By
Project Number
UNCASVILLE, CT
1/8" = 1'-0"
ABC-MP1.4
MECHANICAL PIPING
PLAN BLDGS 'B', 'C'-
LEVEL 4 & ATTIC
Dakota
Partners, Inc.
OXOBOXO
LOFTS
DA
RS
11/01/2017
16-063
A
B
D E
C F
G H
J
K
L M
NORTH
SITE KEY PLAN
No.Description Date
8 Addendum 8 11/5/19
8
8
MSK ABC-MP1.4 12/31/19
MSK ABC-MP1.4
OA
WA
L2.2
L2.A
L2.B
L2.C
L2.D
L2.E
L2.F
L2.G
L2.H
L2.J
L2.K
L2.M
L2.N
L2.1
O1 O2 O3 O4 O5
W1 W2 W3 W4 W5
W6
W7 W8 W9
L2.L
UNIT B-1
(2 BEDROOM)
TYPE A
UNIT B-2
(2 BEDROOM)
UNIT C-3
(2 BEDROOM)TYPE A UNIT C-4
(2 BEDROOM)
TYPE A
ELEVATOR
BUILDING B
BUILDING CBUILDING A
BUILDING G
BUILDING D
HP2
HP2
HP2
2 1/2" SWS&R
1 1/2" SWS&R UP
3" SWS&R DN
1 1/2" SWS&R UP&DN
1"SWS&R DN
3" SWS&R UP
1" SWS&R
HP2
ERV-1
3/4" SWS & R
UP
1 1/2" SWS&R UP
1 1/2" SWS&R DN
1"ø SWR
1"ø SWS
3"ø SWS
3"ø SWR
1"ø SWS
1"ø SWR
1"ø SWR
1"ø SWS
HP5
PROVIDE CIRCUIT SETTER
AT END OF LOOP BRANCH
SIZED FOR PROPER GMP
Scale
Date
Drawn By
Checked By
Project Number
UNCASVILLE, CT
1/8" = 1'-0"
ABC-MP1.B
MECHANICAL PIPING
PLAN BLDG 'B', 'C'-
LEVEL B
Dakota
Partners, Inc.
OXOBOXO
LOFTS
DA
RS
11/01/2017
16-063
A
B
D E
C F
G H
J
K
L M
NORTH
SITE KEY PLAN
No.Description Date
8 Addendum 8 11/5/19
8
MSK ABC-MP1.B 12/31/19
MSK ABC-MP1.B
WA
L2.2
L2.A
L2.B
L2.C
L2.D
L2.E
L2.F
L2.M
L2.N
L2.1
L2.L
UNIT C-1
(2 BEDROOM)
UNIT C-2
(2 BEDROOM)
STAIR 2
ELECTRICAL
METER
ROOM
MAINTENANCE
ROOM
BUILDING B BUILDING C
BUILDING A
(ABOVE)
BUILDING D
BUILDING G
1 1/2" SWS&R UP
3" SWS&R
3" SWS&R
1 1/2"SWS&R
1 1/4" SWS&R
1"SWS&R UP
HP2
1 1/2"ø SWS1 1/2"ø SWR3"ø SWR
3"ø SWS
1"ø SWS
1"ø SWR
1 1/4"ø SWR
1 1/4"ø SWS
HP2
1 1/2" SWS&R UP
1 1/2"ø SWR1 1/2"ø SWS1 1/2"ø SWRFOR CONTINUATION SEEDRAWING F-MP1.1
3" SWS&R UP
PROVIDE CIRCUIT SETTERAT END OF LOOP BRANCHSIZED FOR PROPER GMP
PROVIDE CIRCUIT SETTERAT END OF LOOP BRANCH
SIZED FOR PROPER GMP
PROVIDE CIRCUIT SETTER
AT END OF LOOP BRANCHSIZED FOR PROPER GMP
Scale
Date
Drawn By
Checked By
Project Number
UNCASVILLE, CT
1/8" = 1'-0"
ABC-MP1.SB
MECHANICAL PIPING
PLAN BLDGS 'B', 'C'-
LEVEL SB
Dakota
Partners, Inc.
OXOBOXO
LOFTS
PC
RS
11/01/2017
16-063
A
B
D E
C F
G H
J
K
L M
NORTH
SITE KEY PLAN
No.Description Date
8 Addendum 8 11/5/19
8
MSK ABC-MP1.SB 12/31/19
MSK ABC-MP1.SB
DN
1
A
B
2
OA
O1 O2 O3 O4 O5
BUILDING D
LEVEL 1
UNIT D-1
(2 BEDROOM)
UNIT D-2
(1 BEDROOM)
RECEPTIONKITCHEN
OFFICE
WAITING
AREA
HC LAV.
JAN.
MECH'L
CONFROOM
FITNESSROOM
BUILDING E
LEVEL 1
T
R7-750
T
R6-625
G-150
F-50
EF-1 EF-1
HP2
HP1
EF-1
T
HP7EF-1
T HP7
4"ø4"ø4"ø4"ø
EWH-5
EWH-9
4" EA TO WEATHERPROOFWALL CAP
4" EA TO WEATHERPROOFWALL CAP (TYPICAL FOR 2)
EF-1
4" EA TO WEATHERPROOFWALL CAP
12"x6" AIR TRANSFER ASSEMBLY(AXG). PROVIDE 12"x3" TRANSFERDUCT IN WALL WITH INLET GRILLEAND LOW OUTLET GRILLE (TYPICALFOR ALL)
AXG AXG
AXG
ELECTRICALROOM
BEDROOM 2
BATHROOM
BEDROOM 1
BEDROOM
STAIR D1
EWH-6
ANG
AXG
4" EA TOWEATHERPROOF
WALL CAP
5
HP-HP7KITCHEN
HC LAV.
JAN.
MECH'L
CONFROOM
FITNESSROOM
R7-750
F-125
F-125
F-125
F-125
F-125 F-125 F-50
R6-625
G-150 F-100
F-100F-100
F-100
RI-50T
EF-1
F-50
T
R2-125
EWH-9
EF-1
AXG
12"x6" AIR TRANSFER ASSEMBLY(AXG). PROVIDE 12"x3" TRANSFERDUCT IN WALL WITH INLET GRILLEAND LOW OUTLET GRILLE (TYPICAL
FOR ALL)
AXG
AXG
HP7 20"x8"B-150
HP1
E-450
HP2 R6-600
BATHROOM
B-150
B-150
R1-800 8"x6"AXG
1
A
B
2
OAL2.A
L2.B
L2.C
L2.D
O1 O2 O3 O4 O5
BUILDING D
LEVEL 2
BUILDING E
LEVEL 2
UNIT D-3
(2 BEDROOM)
UNIT D-4(1 BEDROOM)
UNIT E-2
(1 BEDROOM)UNIT E-3
(2 BEDROOM)
T
T
T
HP2
EF-1
C-200
E-450
T HP1
EF-1
EF-1
EF-1
HP1
HP2
4"ø4"ø4"ø4"ø4" EA TO WEATHERPROOFWALL CAP
4" EA TO WEATHERPROOF
WALL CAP
EF-1
EF-1
EF-1
4" EA TO WEATHERPROOFWALL CAP
12"x6" AIR TRANSFER ASSEMBLY(AXG). PROVIDE 12"x3" TRANSFERDUCT IN WALL WITH INLET GRILLEAND LOW OUTLET GRILLE (TYPICALFOR ALL)
AXG
AXG AXG
AXG
AXG
4"ø4" EA TO WEATHERPROOFWALL CAP
12"x6" AIR TRANSFER ASSEMBLY
(AXG). PROVIDE 12"x3" TRANSFERDUCT IN WALL WITH INLET GRILLEAND LOW OUTLET GRILLE (TYPICALFOR ALL)
EWH-8
H-250H-250
B-150
B-150
B-150
HP2
HP1
B-150
B-150
HP2
E-500 R7-800
HP1 AXG
R6-600 10"ø
12"ø8"ø
B-150
R6-600
E-450
4" EA TO WEATHERPROOFWALL CAP
R7-800EF-1
Scale
Date
Drawn By
Checked By
Project Number
UNCASVILLE, CT
1/8" = 1'-0"
DE-MD1.1
MECHANICAL
DUCTWORK PLAN
BLDGS 'D', 'E'- LEVELS
1 & 2
Dakota
Partners, Inc.
OXOBOXO
LOFTS
DA
RS
11/01/2017
16-063
A
B
D E
C F
G H
J
K
L M
NORTH
SITE KEY PLAN
No.Description Date
3 Revision 5 06/10/19
8 Addendum 8 11/5/19
8
8
MSK ABC-MD1.1 12/31/19
MSK ABC-MD1.1
DN
1
A
B
2
OA
O1 O2 O3 O4 O5
BUILDING D
UNIT D-1
(2 BEDROOM)
UNIT D-2
(1 BEDROOM)
RECEPTION
OFFICE
KITCHEN
OFFICE WAITINGAREA
HC LAV.
JAN.
MECH'L
CONF
ROOM
FITNESS
ROOM
BUILDING E
HP2
1"SWS&R
HP7
HP7
1 1/4" SWS&R UP
1 1/4"ø SWR
1 1/4"ø SWS
1" SWS&R UPELECTRICALROOM
BEDROOM 2
LEVEL 1
BEDROOM
BEDROOM 1
3/4"ø SWR
3/4"ø SWS1"ø SWR
1"ø SWS
HP1
1
A
B
2
OA
O1 O2 O3 O4 O5
BUILDING D BUILDING E
UNIT D-3
(2 BEDROOM)
UNIT D-4
(1 BEDROOM)
UNIT E-2(2 BEDROOM)
UNIT E-3(2 BEDROOM)
HP2
HP1
HP2
1 1/2" SWS&R
2"SWS&R HP1
3/4"SWS&R DN
1 1/4" SWS&R DN
1"ø SWR
1" SWS&R DN
LEVEL 2
1"ø SWR
1"ø SWS
1 1/4"ø SWR
1 1/4"ø SWS
1"ø SWS
1"ø SWR1"ø SWS1 1/2"ø SWR
1 1/2"ø SWS
3/4"ø SWR
3/4"ø SWS
2"ø SWS
2"ø SWR
2"ø SWS
2"ø SWR
3/4"ø SWS
3/4"ø SWR
PROVIDE CIRCUIT SETTERAT END OF LOOP BRANCHSIZED FOR PROPER GMP
Scale
Date
Drawn By
Checked By
Project Number
UNCASVILLE, CT
1/8" = 1'-0"
DE-MP1.1
MECHANICAL PIPING
PLAN BLDGS 'D', 'E'-
LEVELS 1 & 2
Dakota
Partners, Inc.
OXOBOXO
LOFTS
DA
RS
11/01/2017
16-063
A
B
D E
C F
G H
J
K
L M
NORTH
SITE KEY PLAN
No.Description Date
3 Revision 5 06/10/19
8 Addendum 8 11/5/19
8
8
MSK DE-MP1.1 12/31/19
MSK DE-MD1.1
LEVEL ONE
S-1
COOLING TOWERSUMP
BOILER ROOM
B-1B-1
T HP9 THP9
8" COMBUSTION AIR INTAKE AND6" AL29-4C(SS) OR PPE FLUEEXHAUST UP THROUGH ROOF(TYPICAL FOR 2 SETS)
LEVEL TWO
HP9
8" OA UP TOROOF CAP INTAKE
CT1
ROOF
8" OA FROM WEATHERPROOF
ROOF CAP DN TO HP9
Scale
Date
Drawn By
Checked By
Project Number
UNCASVILLE, CT
1/8" = 1'-0"
F-MD1.1
MECHANICAL
DUCTWORK PLANS
BLDG 'F'- LEVELS 1 &
2
Dakota
Partners, Inc.
OXOBOXO
LOFTS
DA
RS
11/01/2017
16-063
A
B
D E
C F
G H
J
K
L M
NORTH
SITE KEY PLAN
B1 B1
No.Description Date
8 Addendum 8 11/5/19
8
MSK ABC-MD1.1 12/31/19
MSK ABC-MD1.1
5" SWS&R DN
4" SWS&R LEVEL ONE1/4"=1'-0"
3" SWS&R
S1
ET-1P1P2
AS1
B1 B1
P5P6
P4P3
COOLING TOWER
SUMP
HX1
6" UP TO CT1
6" DN TO S1
CHEMICAL FEED SYSTEMS.PIPING ACCESSORIES,POWER, CONTROLS,
OPERATION AND ISTALLATION
AS PER SPECIFICVATIONSAND DETAILS (TYPICAL FOR 2)
CF-1
CF-2
6" UP TO CT1
AREA RESERVED FORSVE EQUPTMENT SAND FILTRATION EQUPMENTWITH BACKWASH TANK.PIPING, ACCESSORIES, POWER,CONTROLS, OPERATION ANDINSTALLATION AS PER SPECIFICATIONS
AND DETAILS
1" SWS & R UP TO HP9
LEVEL TWO
1/8"=1'-0"
HP-9
1" SWS & R DN
6" DN TO SUMP
CT1
ROOF1/8"=1'-0"
6" DN TO HX1
Scale
Date
Drawn By
Checked By
Project Number
UNCASVILLE, CT
As indicated
F-MP1.1
MECHANICAL PIPING
PLAN BLDG 'F'-
LEVELS 1, 2 AND
ROOF
Dakota
Partners, Inc.
OXOBOXO
LOFTS
DA
RS
11/01/2017
16-063
A
B
D E
C F
G H
J
K
L M
NORTH
SITE KEY PLAN
No.Description Date
MSK F-MP1.1 12/31/19
MSK F-MP1.1
BUILDING H
BUILDING G
UNIT G-5
(2 BEDROOM)
UNIT G-6
(1 BEDROOM)UNIT G-7
(1 BEDROOM)
UNIT G-8
(1 BEDROOM)
UNIT G-9
(1 BEDROOM)
UNIT G-4
(1 BEDROOM)
UNIT G-3
(1 BEDROOM)
UNIT G-2
(1 BEDROOM)
UNIT G-1(2 BEDROOM)
EF-1
4"ø
4"ø
EF-1
4"ø 4"ø
EF-1 EF-1
EF-1
4"ø
4" EA UP TO WEATHERPROOF ROOF CAP(TYPICAL FOR ALL BATH & KITCHEN FANSU.O.N. (TYPICAL)
4"ø
4"ø 4"ø
EF-1
EF-1
EF-1
EF-1
4"ø
EF-1
4"ø EF-1 4"ø 4"ø
4"ø 4"ø
EF-1
EF-1
EF-1
EF-1
4"ø
4"ø 4"ø
EF-1
EF-1
AXG
4"ø
T
HP1
T
HP1
T HP1
T
T
HP1
E-450
T
HP2
T
HP1
B-150
HP1
B-150
8"ø
10"ø
12"ø4" EA UP TO WEATHERPROOF ROOF CAP(TYPICAL FOR ALL BATH & KITCHEN FANSU.O.N. (TYPICAL)
F-100 6"ø8"ø
10"ø
G-175
EF-1
G-175
HP2
8"øB-150
R7-800 A-125THP1
R6-600
E-450
R6-600
HP1
E-450HP1
R6-600
HP1
B-150G-175
9"øR7-800
A-125
HP2
D-350
8"øB-150
R6-600
E-450 B-150
8"ø
R6-600
E-450 8"ø
B-150
R6-600
E-450
T
HP1
E-450
R6-600
8"ø
B-150
B-150
F-100
HP1HP1HP1
F-100
HP1
F-100
G-175
Scale
Date
Drawn By
Checked By
Project Number
UNCASVILLE, CT
1/8" = 1'-0"
G-MD1.1
MECHANICAL
DUCTWORK PLAN
BLDG 'G'- LEVEL 1
Dakota
Partners, Inc.
OXOBOXO
LOFTS
DA
RS
11/01/2017
16-063
A
B
D E
C F
G H
J
K
L M
NORTH
SITE KEY PLAN
No.Description Date
8 Addendum 8 11/5/19
8
MSK G-MD1.1 12/31/19
MSK G-MD1.1
UNIT G-5
(2 BEDROOM)
UNIT G-6
(1 BEDROOM)
UNIT G-7
(1 BEDROOM)
UNIT G-8
(1 BEDROOM)
UNIT G-9
(1 BEDROOM )
BUILDING H
BUILDING G
HP1 HP1
HP1
HP2
HP1
HP1
HP1
HP2 UNIT G-1(2 BEDROOM )
UNIT G-2
(1 BEDROOM )
UNIT G-3
(1 BEDROOM )
3" SWS&R4"ø SWS4"ø SWR3"ø SWR
3"ø SWS
3"ø SWS3"ø SWR
1 1/4"ø SWS
1 1/4"ø SWR 1"ø SWS1"ø SWR3/4"ø SWS
3/4"ø SWR
3/4"ø SWS3/4"ø SWR1"ø SWS
1"ø SWR
3/4"ø SWS3/4"ø SWR3/4"ø SWS3/4"ø SWR3/4"ø SWS3/4"ø SWR3/4"ø SWS3/4"ø SWR3/4"
HP1
1"ø SWS
1"ø SWR
1"ø SWS
1"ø SWR
UNIT G-4(1 BEDROOM)
PROVIDE CIRCUIT SETTERAT END OF LOOP BRANCHSIZED FOR PROPER GMP
Scale
Date
Drawn By
Checked By
Project Number
UNCASVILLE, CT
1/8" = 1'-0"
G-MP1.1
MECHANICAL PIPING
PLAN BLDGS 'G'- level
1
Dakota
Partners, Inc.
OXOBOXO
LOFTS
DA
RS
11/01/2017
16-063
A
B
D E
C F
G H
J
K
L M
NORTH
SITE KEY PLAN
No.Description Date
8 Addendum 8 11/5/198
MSK G-MP1.1 12/31/19
MSK G-MP1.1
UNIT H-2(2 BEDROOM)UNIT H-1
(1 BEDROOM)
METER
ROOMLAUNDRYROOM
BOILER
ROOM JANITOR
LOBBY
BUILDING H
BUILDING J
BUILDING K
T
F-125
T
HP1
HP2
UNIT K-2
(2 BEDROOM)
UNIT K-4
(1 BEDROOM)
UNIT K-1
(1 BEDROOM)
UNIT K-3
(1 BEDROOM)
C-300
T HP1
E-450
T HP1
T
HP1
B-150
D-250
D-250
B-150
R7-800
EF-1
EF-1
4" DRYER EXHAUST UPTO WEATHERPROOF ROOFCAP (TYPICAL FOR 3)
THP8
4"ø
EF-1
4"ø
4"ø4"ø
4"ø
4"ø
4"ø
4"ø
4"ø
4"ø
EF-1
EF-1EF-1
EF-1
EF-1
EF-1
EF-1
EF-1
EF-1
T
HP8
EWH-10
4"ø
4"ø
4" EA UP TOWEATHERPOOF ROOFCAP (TYPICALFOR ALL KITCHENAND BATHROOMFANS)
6" FLUE VENT AND 8"COMBUSTION AIR INTAKETO TERMINATE AT ROOFTOPWEATHERPROOF VENT KIT
B-1 8"ø6"ø
B -150
B-150
B-150
R6-600
G-150
HP8
16"ø
14"ø
14"ø14"ø14"ø
G-100
F-100
G-150
H-250
H-250
G-150
R7-800
14"ø
12"ø
10"ø
8"ø16"x10"
HP6
T
HP6 HP1
E-450
B-150
HP2 6"ø12"ø
R7-800
G-200
G-150
G-150
G-175 9"ø
HP1
HP1
HP1
8"øE-450
F-100
R6-600
F-100
R6-60016"ø
F-100
HP8
F-100
F-100
R6-600
HP1
8"x8"
T
EF-2
PROVIDE REVERSE ACTINGTHERMOSTAT TO ACTIVATEEF-2 UPON REACHING AFIELD ADJUSTABLE SET POINT
OF 85 F.
FD
FD
FD
12X6 INTAKE AND EXHAUST LOUVERSWITH BACKDRAFT DAMPERS ANDFIRE DAMPER
EF-2
6"øFD
Scale
Date
Drawn By
Checked By
Project Number
UNCASVILLE, CT
1/8" = 1'-0"
HK-MD1.1
MECHANICAL
DUCTWORK PLAN
BLDGS, "H" & 'K'-
LEVEL 1
Dakota
Partners, Inc.
OXOBOXO
LOFTS
DA
RS
11/01/2017
16-063
A
B
D E
C F
G H
J
K
L M
NORTH
SITE KEY PLAN
No.Description Date
8 Addendum 8 11/5/19
8
MSK HK-MD1.1 12/31/19
MSK HK-MD1.1
UNIT H-1
(1 BEDROOM)
UNIT H-2
(2 BEDROOM)
METER
ROOMLAUNDRY
ROOM
BOILER AND
SPRINKLERROOM
JANITOR
BUILDING H
BUILDING J
BUILDING K
HP1
3" SWS&R
2" SWS&R
2" SWS&R
2 1/2" SWS&R
BUILDING J
BUILDINGS L & M
3/4" SWS&R
HP1
HP1
3/4" SWS&R 1"ø SWS1"ø SWRHP2
HP1
UNIT K-2
(2 BEDROOM)
UNIT K-1
(1 BEDROOM)UNIT K-3
(1 BEDROOM)
UNIT K-4
(1 BEDROOM)
HP8
HP8 1"
1"
2 1/2"ø SWS
2 1/2"ø SWR
2"ø SWR2"ø SWSScale
Date
Drawn By
Checked By
Project Number
UNCASVILLE, CT
1/8" = 1'-0"
HK-MP1.1
MECHANICAL PIPING
PLAN BLDGS "H" & 'K'-
LEVEL 1
Dakota
Partners, Inc.
OXOBOXO
LOFTS
DA
RS
11/01/2017
16-063
A
B
D E
C F
G H
J
K
L M
NORTH
SITE KEY PLAN
No.Description Date
8 Addendum 8 11/5/19
8
MSK HK-MP1.1 12/31/19
MSK HK-MP1.1
BUILDING J
UNIT J-8
(2 BEDROOM)
UNIT J-7(1 BEDROOM)
UNIT J-6
(2 BEDROOM)
UNIT J-3
(2 BEDROOM)UNIT J-2
(2 BEDROOM)
UNIT J-1
(2 BEDROOM)
UNIT J-5
(2 BEDROOM)
UNIT J-4
(1 BEDROOM)
G-150
H-250
HP2
R6-600 HP1
B-150
T
T
T
HP2
H-250
T
HP2
G-150 H-250
T
HP2
G-150
B-150
T
HP1
T
HP3
T
HP3
EF-1 EF-1
H-250
EF-1
EF-1 EF-1
EF-1 EF-1
EF-1
EF-1EF-1
EF-1
EF-1
EF-1
EF-1
EF-1
EF-1
H-250
F-100
BUILDING H
4"ø
4"ø
4"ø4"ø
4"ø4"ø4"ø
4"ø
4"ø4"ø
4"ø
4"ø
4"ø
4"ø
4"ø
4"ø
4"ø
4" EA UP TO WEATHE
R
P
R
O
O
F
ROOF CAP ( TYPICAL
F
O
R
A
L
L
BATH & KITCHEN U.O
.
N
.
)
E-450
H-250
G-175
G-175
G-175
8"ø 12"ø 12"ø 12"ø10"ø8"ø10"ø12"ø8"ø
8"ø10"ø
10"ø
8"ø
8"ø 10"ø 10"ø 8"ø
12"ø 8"ø
E-450
10"ø8"ø 10"ø 8"ø
G-150
R8-1000
G-175 8"ø8"ø
6"ø
F-100
R6-600
HP1
R7-800
HP2
B-150I-350
R8-1000
HP3
H-250
B-150
R7-800
R7-700
G-150
F-100
14"ø
HP2
HP2
F-100
G-150
EF-1
R7-800
HP1
F-100
HP3
I-350
HP2
G-150
G-150
G-150
G-150
G-150
G-150
EF-1
4"ø
Scale
Date
Drawn By
Checked By
Project Number
UNCASVILLE, CT
1/8" = 1'-0"
J-MD1.1
MECHANICAL
DUCTWORK PLAN
BLDG 'J'- LEVEL 1
Dakota
Partners, Inc.
OXOBOXO
LOFTS
DA
RS
11/01/2017
16-063
A
B
D E
C F
G H
J
K
L M
NORTH
SITE KEY PLAN
No.Description Date
8 Addendum 8 11/5/19
8
MSK J-MD1.1 12/31/19
MSK J-MD1.1
UNIT H-2
(2 BEDROOM)
METER
ROOM
BUILDING J
BUILDING J
UNIT J-8(2 BEDROOM)
UNIT J-7
(1 BEDROOM)
UNIT J-6(2 BEDROOM)
UNIT J-3
(2 BEDROOM)
UNIT J-2
(2 BEDROOM)
UNIT J-1
(2 BEDROOM)
UNIT J-5
(2 BEDROOM)
UNIT J-4
(1 BEDROOM)
HP3
HP1
HP2
HP3
1 1/2" SWS&R
1 1/4" SWS&R
1" SWS&R
HP1
2"ø SWR2"ø SWS
2"ø SWS
2"ø SWR 1"ø SWR1"ø SWS3/4"ø SWS3/4"ø SWR1"ø SWR1"ø SWS1"ø SWS1"ø SWR3/4"ø SWR3/4"ø SWS1"ø SWR1"ø SWS1"ø SWR1"ø SWSHP2
HP2
HP-2 1"ø SWS1"ø SWR1 1/4" SWS&R
HP21"ø SWR1"ø SWSPROVIDE CIRCUIT SETTERAT END OF LOOP BRANCHSIZED FOR PROPER GMP
Scale
Date
Drawn By
Checked By
Project Number
UNCASVILLE, CT
1/8" = 1'-0"
J-MP1.1
MECHANICAL PIPING
PLAN - BLDG 'J'-
LEVEL 1
Dakota
Partners, Inc.
OXOBOXO
LOFTS
DA
RS
11/01/2017
16-063
A
B
D E
C F
G H
J
K
L M
NORTH
SITE KEY PLAN
No.Description Date
8 Addendum 8 11/5/19
8
MSK J-MP1.1 12/31/19
MSK J-MP1.1
MAINTAINANCE
OFFICE/ STORAGE
BUILDING L
EUH-2
T
EUH-2
3
THP2
T
HP1
HP1 T
HP1
HP1
T
H-250
HP2T
E-475
T
HP1
T
HP2
T
HP2
H-250
H-250
T HP2
G-150
HP1 T
T
9"ø
8"øUNIT M-1(1 BEDROOM)UNIT M-2(2 BEDROOMS)
UNIT M-3(2 BEDROOMS)
UNIT M-4(2 BEDROOMS)
UNIT M-5(2 BEDROOMS)
UNIT M-11(2 BEDROOMS)
UNIT M-10
(2 BEDROOMS)
UNIT M-9(2 BEDROOMS)
UNIT M-8(2 BEDROOMS)
UNIT M-7
(2 BEDROOMS)
UNIT M-6
(2 BEDROOMS)
EF-1EF-1
EF-1EF-1
EF-1
EF-1EF-1
EF-1
EF-1
EF-1EF-1
EF-1
EF-1
EF-1
EF-1
EF-1
EF-1
EF-1
EF-1 EF-1
EF-1EF-1
EF-1
G-150
9"ø
F-100
F-100
6"ø
9"ø
F-100 F-100
F-100
10"ø
F-100
HP-3
T
4"ø
4"ø 4"ø
4"ø
4"ø
4" OA UP TOWEATHERPROOF
INTAKE CAP ON ROOF
4"ø4"ø
4"ø
4"ø
4"ø
4"ø 4"ø
4"ø
4"ø
4"ø 4"ø
4"ø 4"ø
4"ø
4"ø
4"ø
4"ø
4"ø
4" OA UP TOWEATHERPROOFINTAKE CAP ON
ROOF
AXG
HP2
4" EA UP TO WEATHERPROOF
ROOF CAP (TYPICAL FOR ALL
KITCHEN AND BATH FANS U.O.N.)
A-125
10"ø10"ø
10"ø6"ø
10"ø 6"ø
8"ø
10"ø
10"ø8"ø
8"ø10"ø8"ø 10"ø
B-150 B-150B-150
8"ø
10"ø
8"ø
10"ø
D-250
G-150
G-150
D-100
R6-600
D-400
D-400
A-100
A-100
D-400
HP2
R7-800
HP1
R6-600
8"ø A-100
R6-600
HP1
4" DIA OA UP TOWEATHERPROOFINTAKE CAP ONROOF
A-100 8"ø HP1
HP1 8"ø
G-150
R7-800B-150
HP2
F-125H-250
F-100H-250
HP2
R7-800
G-175
H-250F-125
HP1
R6-600
C-275A-125
HP2 R7-800
10"ø
8"øA-100
A-100
R6-600
D-400
HP1A-125 4" EA UP TO WEATHERPROOFROOF CAP (TYPICAL FOR ALLKITCHEN AND BATH FANS U.O.N.)
A-100
A-100
C-275 14"ø12"øC-250
G-175
Scale
Date
Drawn By
Checked By
Project Number
UNCASVILLE, CT
1/8" = 1'-0"
LM-MD1.1
MECHANICAL
DUCTWORK PLANS
BLDGS 'L' & 'M'
Dakota
Partners, Inc.
OXOBOXO
LOFTS
DA
RS
11/01/2017
16-063
A
B
D E
C F
G H
J
K
L M
NORTH
SITE KEY PLAN
No.Description Date
8 Addendum 8 11/5/19
8
8
MSK LM-MD1.1 12/31/19
MSK LM-MD1.1
MAINTENANCE
OFFICE/
STORAGE
BUILDING L
3
HP1
HP2
HP1
HP1
HP1
HP1
HP2
HP12"SWS&R
1 1/2" SWS&R1 1/2" SWS&R
2" SWS&R
1 1/4"SWS&R
1 1/4" SWS&R
BUILDING M 3/4"ø SWR1"ø SWR1"ø SWS1"ø SWR1"ø SWS1"ø SWR
3/4"ø SWS1"ø SWS3/4"ø SWS
3/4"ø SWR
HP2
HP2
1"ø SWR1"ø SWS1"ø SWR1"ø SWS1"ø SWR1"ø SWS1"ø SWS 1"ø SWR 1"ø SWR1"ø SWS3/4"ø SWR3/4"ø SWS3/4"ø SWS
3/4"ø SWR
3/4"ø SWR
3/4"ø SWS 3/4"ø SWR3/4"ø SWS3/4"ø SWR
3/4"ø SWS
UNIT M-11(2 BEDROOM)
UNIT M-5(2 BEDROOM)
UNIT M-4(2 BEDROOM)
UNIT M-10(2 BEDROOM)
1 1/2" SWS&R
UNIT M-3(2 BEDROOM)
UNIT M-2
(2 BEDROOM)
UNIT M-1(1 BEDROOM)
1 1/4"ø SWS
1 1/4"ø SWR
HP2
UNIT M-6
(2 BEDROOM)
UNIT M-7(2 BEDROOM)
UNIT M-8(2 BEDROOM)
UNIT M-9(2 BEDROOM)
PROVIDE CIRCUIT SETTER
AT END OF LOOP BRANCHSIZED FOR PROPER GMP
PROVIDE CIRCUIT SETTERAT END OF LOOP BRANCH
SIZED FOR PROPER GMP
Scale
Date
Drawn By
Checked By
Project Number
UNCASVILLE, CT
1/8" = 1'-0"
LM-MP1.1
MECHANICAL PIPING
PLAN BUILDINGS 'L'
AND 'M' LEVEL 1
Dakota
Partners, Inc.
OXOBOXO
LOFTS
DA
RS
11/01/2017
16-063
A
B
D E
C F
G H
J
K
L M
NORTH
SITE KEY PLAN
No.Description Date
8 Addendum 8 11/5/19
8
8
MSK LM-MP1.1 12/31/19
MSK LM-MP1.1
MAX
PUMP TYPES: DS=DOUBLE SUCTION, HS=HORIZONTALMSPLIT, ES=BASE MOUNTED CENTRIFUGAL BASE SUCTION, IL=IN LINE
SCHEDULE OF PUMPS
MANUFACTURER/MODEL NUMBER RPM
NUMBER LOCATION PUMPTYPE
P1 MECHANICALROOM B&G E-1510 2.5AC
FLUID
WATER
GPM
415
HEAD(FT)
150 20 3550
HP VOLT
208
PH
3
REMARKS
SOURCE WATER PUMP, LEAD LAG
MOTOR DATA
P2 MECHANICAL
ROOM WATER 415 150
NOTES:1.PROVIDE FACTORY MOUNTED CIRCUIT TRANSFORMER FOR
STEPPING DOWN LINE VOLTAGE TO CONTROL VOTAGE
HOT WATER BOILERS-BURNERS SCHEDULE
B-1
NUMBER
MECHANICAL
LOCATION
DR1000
MODEL NUMBER REMARKS
BOILER DATA
TYPE
CONDENSING
BURNER DATA
TYPE
MODULATING
INPUT(MBH)
1,000GAS
FUEL
ROOM
SCHEDULE OF EXPANSION TANKS
SYMBOL LOCATION SYSTEM MODEL NO.GPMVOL
GAL REMARKSMANUFACTURER/TANK SYSTEMCONNECTION
AIR SEPARATOR AS1
MANUFACTURER/
MODEL NO.
AIRVENT
ET-1 MECHANICAL
ROOM AMTROL AX-60V 415
∅VOLT
(5 TO 1)CAMUS
MANUFACTURER
940
GROSS
OUTPUT
(MBH)
N/A
BOILERH.P.
H.P.
MOTOR
CONTROL
∅VOLT
SOURCE WATER 33.6 11.5 1/2"5-ADS
B&G E1510 2.5AC
ES
ES 3208
SCHEDULE OF CHEMICAL FEED SYSTEMS
MANUFACTURER MODEL NUMBER REMARKSNUMBER
CF-1 BOILER ROOM
LOCATION
SOURCE WATERSYSTEM
SERVING
VERTICAL
TANK DATA
55 GALLONS 120
ELECTRICAL DATA
TYPE CAPACITY V
POLYETHYLENE
MATERIAL
1
PH
60
HZ
1/3
HP
PROVIDE LOW LEVEL PUMP CUT-OFF, LOW LEVEL ALARM,REMOTE MONITORING CONTACTWATER TREATMENT
APPLICATION
JOHN WOOD JWGP-53-055
20 3550
P3 MECHANICALROOM WATER 160 15B&G e-80 3X3X7C IL 320811150
P4 MECHANICALROOM WATER 160 15B&G e-80 3X3X7C IL 320811150
P5 MECHANICALROOM WATER 420 40B&G e-80 5X5X7B IL 32087.5 1770
P6 MECHANICAL
ROOM WATER 420 40B&G e-80 5X5X7B IL 32087.5 1770
SOURCE WATER PUMP, LEAD LAG
BOILER PUMP
BOILER PUMP
COOLING TOWER PUMP, LEAD LAG
COOLING TOWER PUMP, LEAD LAG
COOLING HEAT REJECTION WILL BE MET BY THE ABOVE SELECTIONS.
NOTE: COOLING TOWER SELECTIONS BASED ON WATERSIDE ECONOMIZER OPERATION. MECHANICAL
VOLT PHWBDB
TEMP FAN (HIGH SPEED)
HPIN.CFM
TOTAL
(FT. HD)
PD
MAX ESPTEMP
OUTIN
GPM
CONDENSER WATER DATA AIR DATA
SCHEDULE OF COOLING TOWERS
CAP.LOCATIONMANUFACTURER/SYMBOL FAN (LOW SPEED)
HP VOLT PHTONSMODEL NUMBER REMARKS
CT-1 BAC XES15E-1212-07EN/W BLDG F ROOF 167 420 95 85 -40,230 N/A 91 73 3 208 3 3 208 3
PROVIDE COMBINATION COMBUSTION AIR INTAKEAND FLUE EXHAUST TO CONCENTRICWALL TERMINAL KIT
TYPE MODEL NUMBER
SCHEDULE OF HEAT EXCHANGERS
SYMBOL MANUFACTURER/SERVEDLOCATIONEQUIPMENT FLUID
CHILLED FLUID SIDEHEATED FLUID SIDE
GPMCAPACITY
MBH FLUID TEMP
OUTIN OUT
GPM
IN
TEMP REMARKSPD
FT
HX-1 MECHANICALROOM PLATE &FRAME CT-1 ALFA LAVAL AQ6-FG 2,100 WATER 420 83 93 WATER 420 96 86 4.82 VIBRATION ISOLATION MOUNTING
REMARKSSYMBOLSAMANUFACTURER /
MODEL NUMBER
WATER-TO-AIR HEAT PUMP SCHEDULE
AREA SERVEDLOCATION
HP1 MECHANICAL ENCLOSURE APARTMENTS WHELAN/VP-0604-B 600 -
(CFM)
OA
*1
(CFM)EFT
HEATING
CAPEATLAT
65 99 21910 68
(°F)BTUH(FWB)(FWB)HOA(Mbtuh)LFT(°F)COP
77 18120 4.8
EFT
COOLING
CAPEATLAT
76.6/64 56/55 17730 86
(°F)BTUH(DB/WB)(DB/WB)HOR(Mbtuh)LFT(°F)EER
96 22510 13.3
FLUID
4.2
(GPM)
FLUID
9.2
(FT H2O)
FLOW RATE PD ELECTRICAL
MCA
12.9
MAX CB(AMPS)
20
PH
1
V
208
HP2 APARTMENTS 800 *1 -65 99 29700 22,900 4.8 76.6/64 56/55 24000 86 96 29600 13.3 5.6 9.2 18 30 1 208
APARTMENTS J-5 & 6 1000 -35700 28400 4.8 28200 35600 7.0 19.2 30HP3
HP4
HP5
BLDG B ATTIC BLDG B CORRIDORS 1200 -47600 37300 4.8 37700 45650 8.4 21.23 35
BLDG A CRAWL SPACE 400 -18500 14800 4.8 14100 17900 3.5 10.58 15
REMARKSPHNUMBERSERVICEMANUFACTURER /
MODEL NUMBER FAN TYPE
SCHEDULE OF FANS
CFMDAMPER
TYPE DRIVEFAN
RPM(IN W.G.)
EXT. S.P.MOTOR DATA
VOLTHP/W RPMCONTROLAREA SERVEDLOCATION
EF-1 DWELLING UNITS KITCHENS AND BATHROOMS GREENHECK/SP-B110 EXHAUST CE WALL SWITCH 100 0.375 950 DIRECT 80W 950 120 1 COORDINATE LOCATION AND INSTALLATION WITH ARCHITECTS RCP
120 3 24 1
PROVIDE WITH STARTER, DISCONNECT SWITCH,
VIBRATION ISOLATION MOUNTING
68 77
68 77
68 77
68 77
68 77
68 77
86 96
86 96
86 96
86 96
86 96
13.3
13.3
13.3
13.3
13.3
9.2
9.2
5.2
9.2
9.4
1 208
1 208
1 208
1 208
1 208
HP6 APT K-2 LAV APARTMENT K-2
HP7 BLDG E MECH ROOM BLDG E OFFICE & FITNESS
HP9 BLDG F
HP8 BLDG H MECH ROOM BLDG G,H,J,K,M CORRIDOR
600 21910
800 26600
1000 200 35700
65 99
65 99
65 99
65 99
65 99
65 99 68 77
4.8
4.8
4.8
76.6/64 56/55
76.6/64 56/55
76.6/64 56/55
76.6/64 56/55
76.6/64 56/55
76.6/64 56/55
18120
22900
28400
17730
23300
28200
22510
29400
35600
4.2
5.6
7.0
12.9 20
18 30
19.2 30 1 208
*1
*1
*1
*1
*1
86 96 13.3 9.2
MECHANICAL ENCLOSURE
MECHANICAL ENCLOSURE
WHELAN/VP-0804-B
WHELAN/VP-1004-B
WHELAN/CASH-036AB
WHELAN/CASH-012AB
WHELAN/CASH-018AB
WHELAN/CASH-024AB
WHELAN/CASH-030AB
BLDG A CORRIDORS
NOTES:1. *1= OUTSIDE (VENTILATION) AIR PROVIDED BY OPERABLE WINDOWS UNLESS OTHERWISE NOTED. WHERE HARD DUCT OA CONNECTIONS ARE SHOWN COORDINATE INSTALLATION WITH MANUFACTURER (TYPICAL)
2. CONTRACTOR SHALL COORDINATE ALL HEAT PUMP MOUNTING HEIGHTS, SUPPLY & RETURN PLENUMS, ENCLOSURES, DUCT TAKEOFFS AND ELEVATIONS, DIFFUSER AND GRILLE MOUNTING AND LOCATIONS, ETC. WITH ARCHITECTURAL, STRUCTURAL AND ALL WORK OF OTHER TRADES PRIOR TO INSTALLATION (TYPICAL)
3. PROVIDE CONDENSATE PUMPS FOR ALL HEAT PUMP UNITS AS REQUIRED. VERIFY LOCATIONS, QUANTITIES, PIPE ROUTING, INDIRECT DRAIN CONNECTIONS, ETC. WITH UNIT LAYOUTS AND MANUFACTURER RECOMMENDATIONS PRIOR TO ORDERING AND INSTALLATION (TYPICAL)
1000 200 357006599 68 77 4.8 76.6/64 56/5528400 28200 35600 7.0 19.2 30 1 208869613.3 9.2WHELAN/CASH-030ABBLDG F
CF-2 BOILER ROOM COOLING TOWERLOOP VERTICAL 55 GALLONS 120POLYETHYLENE 1 60 1/3 PROVIDE LOW LEVEL PUMP CUT-OFF, LOW LEVEL ALARM,REMOTE MONITORING CONTACTWATER TREATMENTJOHN WOOD JWGP-53-055
VOLUME
(GALLONS)
ACCEPTANCE
FAN TYPES: CRCE=CENTRIFUGAL ROOF CURB MOUNTED EXHAUSTER
PRCE=PROPELLER ROOF CURB MOUNTED EXHAUSTER
PRCS=PROPELLER ROOF CURB MOUNTED SUPPLY FAN
CFC=CENTRIFUGAL FORWARD CURVED
CE=CEILING MOUNTED EXHAUSTER
CRCU=CENTRIFUGAL ROOF CURB UPBLAST
CAF=CENTRIFUGAL AIR FOIL CBI=CENTRIFUGAL BACKWARD INCLINED VA=VANE AXIAL
EF-2 BUILDING H METER ROOM GREENHECK/SP-B110 EXHAUST CE REVERSE-ACTING THERMOSTAT GRAVITYBACK DRAFT
GRAVITYBACK DRAFT
9501000.375 DIRECT 80W 950 120 1
Scale
Date
Drawn By
Checked By
Project Number
UNCASVILLE, CT
1/8" = 1'-0"
M2.1
MECHANICAL
SCHEDULES
Dakota
Partners, Inc.
OXOBOXO
LOFTS
Checker
Author
11/01/2017
16-063
No.Description Date
8 Addendum 8 11/5/19
8
MSK M2.1 12/31/19
MSK M2.1
MODEL NUMBER
SCHEDULE OF ENERGY RECOVERY VENTILATORS
SYMBOL MANUFACTURER/LOCATION CFM
EXHAUST AIROUTSIDE AIR
CFM S.P. (IN. WG.)
TOTALEXT.
REMARKS
ERV-1 BUILDING ACRAWL SPACE A BUILDING RENEWAIRE/480 IN 250 0.75 N/A 240 .75 N/A
ELECTRICAL
VOLTHP PH
11200.6
WINTER
452
S.P. (IN. WG.)
TOTALEXT.
SUMMER SUMMER
EAT DB/WB LAT DB/WB
91/73 80/63
AREA
SERVED WEIGHT(LBS)
150
EAT DB
WINTER
LAT
ERV-2 BUILDINGB ATTIC B BUILDING RENEWAIRE/HE 1.5X INH 800 0.75 N/A 750 .75 N/A 11201.0 452 91/73 80/63 400
MCA
9
18
MOCP
15
20
ELECTRIC HEATER SCHEDULE
MANUFACTURER/MODEL NUMBER
CAPACITY(BTUH)SYMBOL LOCATION
EWH-1 BUILDING 'B' ELECTRICAL ROOM BERKO / SRA-1012A 3413
CFM
65
ENT LVG
104
TEMP (°F)
AIR DATA ELECTRICAL DATA
KW
1.0 8.4
A VOLT PH
120 1 INTEGRAL THERMOSTAT, SURFACE MOUNTING SLEEVE
REMARKS
BUILDING 'B' SOUTH STAIRS
BUILDING 'B' NORTH VESTIBULE
EWH-2
EWH-3
BUILDING 'B' MAINTENANCE ROOMEUH-1
BLDG B LAUNDRY ROOMEWH-4
UNIT D-2 BATHROOMEWH-5
UNIT D-1 ELECTRICAL ROOMEWH-6
BUILDING 'D' STAIRSEWH-7
UNIT D-4 BATHROOMEWH-8
BUILDING 'E' STAIRSEWH-9
BUILDING 'H' METERROOMEWH-10
BERKO / SRA-1812A
BERKO / SRA-1012A
BERKO / SRA-1512A
BERKO / SRA-1012A
BERKO / SRA-1812A
BERKO / SRA-1512A
BERKO / HUHAA-524
NOTE- PROVIDE ALL UNITS WITH TAMPERPROOF ENCLOSURE
BERKO / SRA-1512A
BERKO / SRA-1512A
BERKO / SRA-1512A
6142
3413
2560
2560
2560
5120
2560
3071
5120
65
65
65
65
65
65
65
65
65
60
60
60
60
60
60
60
60
60
60
60
111
104
98
98
98
108
98
101
108
118
1.8
1.0
0.75
0.75
0.75
1.5
0.90
0.75
1.5
5.0 21.0
12.5
7.5
6.25
12.5
6.25
6.25
6.25
8.4
15.0 120
120
120
120
120
120
120
120
120
208
1
1
1
1
1
1
1
1
1
317,000 350
INTEGRAL THERMOSTAT, SURFACE MOUNTING SLEEVE
INTEGRAL THERMOSTAT, SURFACE MOUNTING SLEEVE
INTEGRAL THERMOSTAT, RECESSED MOUNTINGSLEEVE
INTEGRAL THERMOSTAT, SURFACE MOUNTING SLEEVE
INTEGRAL THERMOSTAT, RECESSED MOUNTINGSLEEVE
INTEGRAL THERMOSTAT, SURFACE MOUNTING SLEEVE
INTEGRAL THERMOSTAT, SURFACE MOUNTING SLEEVE
WALL THERMOSTAT, HORIZONTAL MOUNT
INTEGRAL THERMOSTAT, RECESSED MOUNTINGSLEEVEINTEGRAL THERMOSTAT, RECESSED MOUNTINGSLEEVE
REMARKSTHROWINLET SIZENUMBERTYPE
DIFFUSERS, REGISTERS & GRILLES SCHEDULE
FACE SIZEMANUFACTURER / MODEL NUMBER
NOTES:1. CONTRACTOR IS RESPONSIBLE FOR COORDINATION OF AIR INLETS AND OUTLETS
SO AS TO ACHIEVE COMPATIBILITY WITH SELECTED CEILING, WALL OR DUCT SYSTEM
2. AIR INLETS AND OUTLETS SHALL BE SELECTED BASED ON THE FOLLOWING CRITERIA
- MAXIMUM INLET OR OUTLET VELOCITY 500 FPM
- MAXIMUM NC RATING NOT TO EXCEED 35
- THROW PATTERN AS PER SCHEDULES AND PLANS
- THROWS SHALL NOT INTERSECT OR REACH WALLS AND PARTITIONS3. FINISH SELECTION BY ARCHITECT
GALVANIZED STEELAMETALIRE/V4004D SIDEWALL MOUNT 12 X 8 10 X 6 -ADJUSTABLE
NECK SIZE DAMPER
GALVANIZED STEELB14 X 8 12 X 6 -ADJUSTABLE
GALVANIZED STEELC20 X 8 18 X 6 -ADJUSTABLE
GALVANIZED STEELD18 X 10 16 X 8 -ADJUSTABLE
GALVANIZED STEELR1LINDAB/RGS-3 -INTEGRAL
GALVANIZED STEELR2LINDAB/RGS-3 -INTEGRAL
GALVANIZED STEELR3LINDAB/RGS-3 -INTEGRAL
GALVANIZED STEELG16 X 7 13 X 6 -ADJUSTABLE
GALVANIZED STEELE22 X 10 20 X 8 -ADJUSTABLE
GALVANIZED STEELFLINDAB/RGS-3 20 X 4 17 X 3 -ADJUSTABLE INTEGRALDUCT MOUNT
DUCT MOUNT
DUCT MOUNT
DUCT MOUNT
20 X 4 17 X 3
16 X 7 13 X 6
20 X 7 17 X 6
-
-
-
GALVANIZED STEELH20 X 7 17 X 6 -ADJUSTABLE
GALVANIZED STEELI24 X 7 21 X 6 -ADJUSTABLE
GALVANIZED STEELR4METALAIRE/RHD 12 X 8 10 X 6 -SIDEWALL MOUNT OBD-
GALVANIZED STEELR5METALAIRE/RHD 20 X 10 18 X 8 -SIDEWALL MOUNT OBD-
GALVANIZED STEELR6METALAIRE/RHD 20 X 14 18 X 12 -SIDEWALL MOUNT OBD-
GALVANIZED STEELR7METALAIRE/RHD 30 X 14 28 X 12 -SIDEWALL MOUNT OBD-
GALVANIZED STEELR8METALAIRE/RHD 26 X 20 24 X 18 -SIDEWALL MOUNT OBD-
GALVANIZED STEELR9METALAIRE/RHD 32 X 26 30 X 24 -SIDEWALL MOUNT OBD-
GALVANIZED STEELR10METALAIRE/RHD 14 X 14 12 X 12 -CEILING MOUNT OBD-
GALVANIZED STEELE1METALAIRE/RHD 10 X 10 8 X 8 -CEILING MOUNT OBD-
OBD
OBD
OBD
OBD
OBD
INTEGRAL
INTEGRAL
INTEGRAL
SIDEWALL MOUNT
SIDEWALL MOUNT
SIDEWALL MOUNT
SIDEWALL MOUNT
DUCT MOUNT
DUCT MOUNT
DUCT MOUNT
METALIRE/V4004D
METALIRE/V4004D
METALIRE/V4004D
METALIRE/V4004D
LINDAB/RGS-3
LINDAB/RGS-3
LINDAB/RGS-3
BUILDING 'L'EUH-2 BERKO / HUHAA-524 60 118 5.0 21.0 208 317,000 350 WALL THERMOSTAT, HORIZONTAL MOUNT
8
8
Scale
Date
Drawn By
Checked By
Project Number
UNCASVILLE, CT
1/8" = 1'-0"
M2.2
MECHANICAL
SCHEDULES
Dakota
Partners, Inc.
OXOBOXO
LOFTS
PC
RMS
11/01/2017
16-063
No.Description Date
3 Revision 5 06/10/19
8 Addendum 8 11/5/19
MSK M2.2 12/31/19
MSK M2.2
BOILERBOILER
5"
4"
6"
P-3
5"
CHEMICALTREATMENT
3/4"
3/4" DRAIN VALVEWITH HOSECONNECTION
DIFFERENTIALPRESSURE SWITCH
P-4
6"
COOLING TOWER PIPING DETAIL
ASME
PRESSURE REGULATOR
UNION (TYP)
1" CW MAKE-UP
1 1/2"
BYPASS
FIN. FLOOR
P-1
P-2
1 1/2"
SAND FILTER
1 1/2"BACKWASHDRAINPIPING
SANDFILTERALARMDICW3/4"
1"
CHEMICAL TREATMENT
CT-1
LIQUID LEVELCONTROLLER
NOTE:HEAT TRACE AND INSULATE ALL CONDENSERWATER SUPPLY, RETURN, DRAIN AND OVERFLOWPIPING. INCLUDE ALL VALVES AND OTHERPIPING SUBJECT TO FREEZING.
T
T
WATERTEMPERATURE
DFVDO
DI BYPAO
VIBRATION SWITCH
DI
CWR
6"
2"
NOTES:
PROVIDE SAND FILTRATION SYSTEM CONSISTING OF:
(2) PEP: MODEL #HMF-18 WITH FLOWRATE OF 35 GPM.
(1) 100 GALLON BACKWASH TANK.
FILTER CONTROL PANEL WITH CONTROLLER.
BACKWASH LOCK OUT.
NOTES:1.PROVIDE WITH 3 PROBE ELECTRIC LEVEL CONTROL AND ASSOCIATED MAKE-UP WATER VALVE.
2.PROVIDE WITH INVERTER DUTY MOTOR.
3. SEE SPECIFICATIONS FOR DETAIL INFORMATION.
B-1
TT
TTTP
P
T
P
T
T
DP
B-1
AS-1
VFD
VFD
AI
AI
AI
T T
T T
NOTES:
ATC CONTRACTOR SHALL PROVIDEADDITIONAL INPUT AND OUTPUT POINTS TOPROVIDE COMPLETE AND OPERATIONALSYSTEM OF THE CONDENSER WATER LOOP.THE FINAL CHECK OUT AND VERIFICTIONAND PROPER SYSTEM OPERATION SHALL BEPERFORMED BY ATCATC CONTRACTOR SHALL REPORTRESULTS OF SYSTEM CHECK OUT INWRITING TO OWNER, ARCHITECT ANDENGINEER.
P-6
P-5
ET-1
CF-2
1" DRAIN LINE WITHSOLENOID CONTROL ANDSHUTOFF VALVE. ROUTE TONEAREST FLOOR DRAIN,SEE PLUMBING PLANS
BUTTERFLYVALVE(TYPICAL)
FLEXIBLE PIPINGCONNECTION (TYPICAL)
CF-1
1-1/4" CW MAKE-UP TOCOOLING TOWER LOOP. PROVIDESHUT OFF VALVE, REDUCEDPRESSURE BACKFLOW PREVENTERAND SOLENOID CONTROL VALVEWITH MANUAL BYPASS
OVERFLOWDRAIN
COOLING TOWER SUMP DRAIN PIPED TOCONDENSER WATER SUPPLY FOR DRAININGIN BASEMENT MECHANICAL ROOM
1.
2.
1-1/4"
PIPE TO FLOORDRAIN FULL SIZE OFRELIEF VALVEDISCHARGEDIAPHRAGM TYPEEXPANSION TANK
HOUSEKEEPING PAD
STRAINERBLOW-OFF VALVE& CAP
BUTTERFLY VALVE(TYPICAL)FLEXIBLE PIPINGCONNECTION (TYPICAL)CWS4" CONC. PAD
GLOBE VALVE
WITH GUAGE COCKPRESSURE GUAGE
VALVEPRESSURE RELIEF
AIR SIDE DRAIN
TRIPLE DUTY VALVEB&G. REFER TODWG.UNION(TYPICAL)
CHARGING/TEST VALVE
(TYPICAL)GATE VALVE
3"
4"
4"
TEMPERATUREGAUGE (TYPICAL)
TEMPERATURESENSOR (TYPICAL)
P
T
P
T
T
DRAIN VALVE(TYPICAL)
3"
4"
HWR
S-1REMOTE SUMP INBOILER ROOM
6"
6"
6"
T
T
5"SWRSWRSWSHX-1
PRESSURE GAUGE(TYPICAL)
TEMPERATURESENSOR (TYPICAL)
PRESSURE GAUGE(TYPICAL)
TEMPERATUREGAUGE (TYPICAL)
CHEMICALTREATMENT
PUMP BYMANUFACTURER
CHEMICALTREATMENTPUMP BYMANUFACTURER
Scale
Date
Drawn By
Checked By
Project Number
UNCASVILLE, CT
1" = 10'-0"
M3.4
MECHANICAL DETAIL
Dakota
Partners, Inc.
OXOBOXO
LOFTS
Checker
Author
11/01/2017
16-063
No.Description Date
MSK M3.4 12/31/19