ASK114 - BUILDING AB EAVE DETAIL
MEMBRANE ROOF SYSTEM.1 1/2" RIGID INSULATION.3/4" PLYWOOD ROOF SHEATHING.RAFTER VENT AT EACH BAY.2X ROOF RAFTERS. SEE STRUCTURAL DRAWINGS.2X CEILING JOISTS.FIBERGLASS BATT INSULATION.WOOD BLOCKING.WOOD BLOCKING.ALUMINUM DRIP EDGE.1x8 FASCIA BOARD.TOP OF PLATE7'-1 1/2" A.F.F.1x SOFFIT BOARD.2" CONTINUOUS SCREENED SOFFIT VENT.SELF-ADHERING FLEXIBLE FLASHING.GALVANIZED STEEL LINTEL.BRICK WEEP.WINDOW MOULDING.WINDOW. SEE SCHEDULE.PAINTED GWB WINDOW JAMBS.2X WOOD TOP PLATESLOPED PAINTED GWB CEILING AT ROOF RAFTERS.DateDrawn byScaleREF:1 1/2" = 1'-0"5/20/2020 1:18:09 PMOXOBOXO LOFTS42 Pink Row Uncasville, CT 06382ASK-11405/20/20BUILDING AB EAVE DETAILSKChecker1 1/2" = 1'-0"ASK-1141BUILDING AB EAVE DETAIL