HomeMy WebLinkAbout2020-05-07 Ox Compiled 11x17sSTAIR B
(LEVEL SB)
1
ASK-045Br1 1
ASK-045Cr1
NEW 2-HOUR RATED
CEILING BELOW
EXISTING TIMBER
FRAMED FLOOR.
NEW WOOD FRAMED
STAIR LANDING.
NEW WOOD FRAMED
STAIR LANDING.
NEW COLUMN
SUPPORTING CUT
WOOD TIMBER
NEW COLUMN
SUPPORTING NEW
STAIR LANDING
SEE RESPONSE TO RFI 029
Date
Drawn by
Scale
REF:
3/8" = 1'-0"
2/5/2020 12:29:36 PM
OXOBOXO LOFTS
42 Pink Row Uncasville, CT 06382 ASK-045Ar1
01/23/2020, Rev.
1/29/20
BUILDING B STAIR 2 -PLAN AT LEVEL SB
Author
RFI35 and
RFI45
3/8" = 1'-0"ASK-045Ar1
1 BLDG B PARTIAL CEILING PLAN - LEVEL SB
EXISTING GRANITE WALL TO REMAIN.EXISTING BRICK INFILL BETWEEN WOOD RAFTERS/OUTRIGGERS.EXISTING ROOF EAVE SOFFIT, FACIA AND TRIM TO REMAIN.NEW RAIN GUTTER.NEW FIBERGLASS BATT INSULATION BETWEEN EXISTING ROOF RAFTERS.NEW PAINTED GWB FASTENED TO UNDERSIDE OF FATERS.NEW KNEE WALL WITH EXTERIOR SIDE ALIGNED WITH EXISTING EXTERIOR WALL.FILL SPACE FROM EXTERIOR FACE OF BRICK WALL TO EDGE OF EXISTING FLOOR WITH NEW WOOD SUBFLOOR. MATCH THICKNESS OF EXISTING HEAVY TIMBER FLOOR AND ALIGNED WITH EXISTING FLOOR. DEMOLISH EXISTING PLASTER AND LATHE KNEE WALL.EXISTING WOOD POSTS TO REMAIN.NEW FRAMING BETWEEN EXISTING WOOD POSTS.PACK VOID WITH MINERAL WOOL. EXISTING PLASTER AND LATHE AT MASONRY WALL TO REMAIN.EXISTING HEAVY TIMBER BEAMS/JIOSTS TO REMAIN.EXISTING HEAVY TIMBER FLOOR TO REMAIN.NEW TAPERED WOOD SLEEPERS.NEW SUBFLOOR PANELS.NEW GYPCRETE UNDERLAYMENT.NEW FINISH FLOOR SEE FINISH FLOOR PLANS. NEW ACOUSTIC MAT.DateDrawn byScaleREF:1" = 1'-0"12/20/2019 4:14:25 PMOXOBOXO LOFTS42 Pink Row Uncasville, CT 06382ASK-02812/20/2019BUILDING B ROOF EAVE DETAIL-WITH NEWKNEE WALL DETAILSKBUILDINGOFFICIALCOMMENT
L2.M
CORRIDOR FURRING
RATED WALL
STAIR 2
LEVEL 1 FLOOR (2-4 SIM.)
LEVEL B FLOOR
HEAVY TIMBER
FLOOR TO REMAIN
HEAVY TIMBER
FRAMING TO REMAIN
NEW UNRATED FLOOR
TO FLOOR PARTITION
NEW RATED SHAFTWALL FROM
BASEMENT FLOOR TO UNDERSIDE
OF TIMBER OR FIRST FLOOR
NEW EXPANSION
TOP TRACK
NEW FIRE-RATED
HORIZONTAL ASSEMBLY
W3
C3
HEAVY TIMBER
FLOOR TO REMAIN
HEAVY TIMBER
FRAMING TO REMAIN
NEW UNRATED FLOOR
TO FLOOR PARTITION
NEW RATED SHAFTWALL FROM
FIRST FLOOR TO UNDERSIDE OF
TIMBER OR SECOND FLOOR
Date
Drawn by
Scale
REF:
1 1/2" = 1'-0"
2/5/2020 12:30:46 PM
OXOBOXO LOFTS
42 Pink Row Uncasville, CT 06382 ASK-045Br1
01/23/2020, Rev.
1/29/20
BUILDING B STAIR 2 -N-S SECTION
SK
RFI 035 and
RFI 045
APARTMENT FURRING
RATED WALL
STAIR 2
LEVEL 2 thru 4
LEVEL B and 1
HEAVY TIMBER FLOOR TO
REMAIN. PROVIDE SOLID
BLOCKING WHERE FLOOR
INTERRUPTS RATED WALL, TYP.
HEAVY TIMBER FRAMING TO
REMAIN.
NEW UNRATED FLOOR
TO FLOOR PARTITION.
NEW RATED SHAFTWALL
FROM FLOOR TO
UNDERSIDE OF FLOOR.
W3
W3
W3
NEW UNRATED FLOOR
TO FLOOR PARTITION.
NEW RATED SHAFTWALL
FROM FLOOR TO
UNDERSIDE OF FLOOR.
HEAVY TIMBER FLOOR TO
REMAIN. PROVIDE SOLID
BLOCKING WHERE FLOOR
INTERRUPTS RATED WALL, TYP.
EXPANSION TOP TRACK.
Date
Drawn by
Scale
REF:
1 1/2" = 1'-0"
2/5/2020 12:31:48 PM
OXOBOXO LOFTS
42 Pink Row Uncasville, CT 06382 ASK-045Cr1
01/23/2020, Rev.
1/29/20
BUILDING B STAIR 2 -E-W SECTION
Author
RFI35 and
RFI45
OXOBOXO LOFTS - ASK-043A CLOSET DOOR REVISTIONS AT UNIT G1 12/27/19
OXOBOXO LOFTS - ASK-043B CLOSET DOOR REVISTIONS AT UNIT G3 12/27/19
OXOBOXO LOFTS - ASK-043C CLOSET DOOR REVISTIONS AT UNIT G7 12/27/19
FLOOD VENTS 5W X 2 H
EL: 27'-0"
TO B.O. VENT
ASK-006
R1 3
ASK-006
R1
2
FLOOD VENT 5W X 2 H
EL : 27'-0"
TO B.O. VENT
BUILDING G 5800 S.F.
(1) 5W X 2H VENT COVERS 2000
S.F. PER ATTACHED CHART , SO
3 VENTS ARE NEEDED
K-A4.1 5
F.F.E. : 26'-5 3/8"
BLDG G - LEVEL 1 EXIST
26' - 5 3/8"
BLDG G ROOF TRUSS
44' - 5 7/8"
BLDG G - LEVEL 1 NEW
30' - 5"
GRADE
28'-0"
24'-0"
GRADE
METAL FRAMED WOOD FLOOR
WOOD FLOORING OVER CONCRETE SLAB B.O. FLOOD VENT
27'-00"
B.O. FLOOD VENT
27'-00"
BLDG G - LEVEL 1 EXIST
26' - 5 3/8"
BLDG G - LEVEL 1 NEW
30' - 5"GRADE
28'-0"
FLOOD VENT 5W X 2H
METAL FRAMED WOOD FLOOR
WOOD FLORING OVER CONCRETE SLAB
B.O. FLOOD VENT
28'-6"DateDrawn byScaleREF:3/32" = 1'-0"3/9/2020 4:31:49 PMOXOBOXO LOFTS42 Pink Row Uncasville, CT 06382ASK-006 R13/9/20FLOOD VENT BUILDING GTGBLDG G3/32" = 1'-0"ASK-006 R1
1 BLDG G - CRAWL SPACE FLOOR PLAN
A
B
D E
C F
G H
J
K
L M
NORTH
SITE KEY PLAN
3/32" = 1'-0"ASK-006 R1
2 SOUTH ELEVATION BUILDING G
3/32" = 1'-0"ASK-006 R1
3 WEST ELEVATION BLDG G
BUILDING H FLOOD VENTS 5W X 1 H BUILDING JBUILDING GFLOOD VENTS 5W X 2 H FLOOD VENTS 5W X 2 H FLOOD VENTS 5W X 2 H 30" X 36" INSULATED LOCKING ACCESS HATCH IN CORRIDOR ABOVE30" X 36" INSULATED ACCESS HATCH IN JANITOR CL. ABOVE30" X 36" INSULATED ACCESS HATCH IN CORRIDOR CLOSET ABOVEDateDrawn byScaleREF:1/32" = 1'-0"12/26/2019 11:02:53 AMOXOBOXO LOFTS42 Pink Row Uncasville, CT 06382ASK-3712/23/2019BUILDING G,H,J CRAWL SPACEAuthorCheckerABDECFGHJKLMNORTHSITE KEY PLAN
BUILDING H 2900 S.F.
FLOOD VENTS
5W X 1 H
IN LOWER
CRAWL SPACE
EL: 23'-0"
ASK-008
R1
3
ASK-008
R12
(1) 5W X 1H VENT COVERS 1000 SF PER
ATTACHED CHART, SO 3 VENTS ARE NEEDED
EXISTING
CRAWL SPACE
OXOBOXO BROOK
NORTH BANK
F.F.E. : 26'-10 3/8"
UPPER CRAWL SPACE
F.F.E. : 22' - 5"
FLOOD VENTS
5W X 1 H
IN UPPER
CRAWL SPACE
EL: 27'-4"
BLDG H LEVEL 1 EXIST
26' - 10 3/8"
BLDG HJ LEVEL 1 NEW
30' - 5"
EXISTING CRAWL SPACE
24'-0"
GRADE
EXISTING LOWER CRAWL SPACE BEYOND
VENTED ON SOUTH WALL ABOVE
OXOBOXO BROOK. SEE DRAWING BELOW.
METAL FRAMED WOOD FLOOR
CONCRETE SLAB
RAT SLAB22'-5"
27'-4"
B.O. FOOD VENT
BLDG H LEVEL 1 EXIST
26' - 10 3/8"
BLDG HJ LEVEL 1 NEW
30' - 5"
EXISTING LOWER CRAWL SPACE
OXOBOXO BROOK BELOW
CONCRETE SLAB
METAL FRAME WOOD FLOOR
RAT SLAB22' - 5"B.O. FLOOD VENT
23' - 0"DateDrawn byScaleREF:3/32" = 1'-0"3/9/2020 4:22:51 PMOXOBOXO LOFTS42 Pink Row Uncasville, CT 06382ASK-008 R13/9/20FLOOD VENT BUILDING HTGBLDG H3/32" = 1'-0"ASK-008 R1
1 BLDG H- CRAWL SPACE FLOOR PLAN
3/32" = 1'-0"ASK-008 R1
2 BLDG H EAST ELEVATION
3/32" = 1'-0"ASK-008 R1
3 BLDG H SECTION LOOKING NORTH
A
B
D E
C F
G H
J
K
L M
NORTH
SITE KEY PLAN
UNIT J-4(1 BEDROOM)30' - 5"W5W5W1W1W1W1W7A11' - 4"4"8' - 8"4"7' - 4"2' - 9"6"1' - 1"6"6"6' - 2"4"3' - 6"1' - 1"6"1' - 1"6"
2' - 2"
5' - 2"
6"
4' - 6"
4"
9' - 7"
6"6' - 0"6"D-2AD-4D-2AD-2D-2D-4BD-3AD-1D-1E-4AE-4AE-1AAE-1AAE-1AAH-2AD-5ABATHROOM(TYPE 34)KITCHEN(TYPE 31)BATHROOM(TYPE 38)KITCHEN(TYPE 32)BATHROOM(TYPE 38)BATHROOM(TYPE 39)W7AW5W5W7AW5W5W1W1W5W5W5W7AW5W5CLOSETLIN.CLOS.BEDROOMCORRIDORD-57COATCLOS.COATCLOSETBEDROOM 1CLOSET30' - 5"MECH.D-3DW5F35DateDrawn byScaleREF:1/4" = 1'-0"12/23/2019 1:53:41 PMOXOBOXO LOFTS42 Pink Row Uncasville, CT 06382ASK-03412/20/2019BUILDING J LEVEL ONETGHJ-A1.2ABDECFGHJKLMNORTHSITE KEY PLAN
BUILDING J 9000 S.F.
ASK-007
R1
2
ASK-007
R13
FLOOD VENTS
5W X 2 H
EL: 27'-0"
TO B.O. VENT
FLOOD VENT
5W X 2 H
EL: 27'-0"
TO B.O. VENT
(1) 5W X 2H VENT COVERS 2000
S.F. PER ATTACHED CHART
SO (5) VENTS ARE NEEDED
F.F.E. : 26'-5 3/8"
FLOOD VENTS
5W X 2 H
EL: 27'-0"
TO B.O. VENT
BLDG J LEVEL 1 EXIST
26' - 5 3/8"
BLDG HJ LEVEL 1 NEW
30' - 5"
GRADE
24'-0"
OXOBOXO BROOK BELOW
METAL FRAMED WOOD FLOOR
CONCRETE SLAB
B.O. FLOOD VENT
27'-00"
B.O. FLOOD VENT
27'-00"
B.O. FLOOD VENT
27'-00"
BLDG J LEVEL 1 EXIST
26' - 5 3/8"
BLDG HJ LEVEL 1 NEW
30' - 5"
GRADE
16'-0"
28'-0"
GRADEMETAL FRAMED WOOD FLOOR
CONCRETE SLAB B.O. FLOOD VENT
27'-0"DateDrawn byScaleREF:1/16" = 1'-0"3/9/2020 4:21:25 PMOXOBOXO LOFTS42 Pink Row Uncasville, CT 06382ASK-007 R13/9/20FLOOD VENT BUILDING JTGBLDG J1/16" = 1'-0"ASK-007 R1
1 BLDG J - CRAWL SPACE FLOOR PLAN
1/16" = 1'-0"ASK-007 R1
2 BLDG J SOUTH ELEVATION
1/16" = 1'-0"ASK-007 R1
3 BLDG J EAST ELEVATION
A
B
D E
C F
G H
J
K
L M
NORTH
SITE KEY PLAN
OXOBOXO BROOKNEW MASONRY WALLS BETWEEN MASONRY PIERS TO REPLACE WOOD FRAMED WALLS.EXISTING OPENING TO BUILDING M BASEMENT.FLOOD VENTS6W X 3H,TYP.EL: 23'-0"TO B.O. VENTFLOOD VENT 5W X 1 HEL:26'-11"TO B.O. VENT ASK-005R12ASK-005R13BUILDING K 2,000 S.F.(1) 6W X 3H VENT COVERS 3,600S.F. PER ATTACHED CHART SO(4) VENTS ARE NEEDEDBLDG KEXISTING DIRT FLOOR CRAWL SPACEFLOOD WATER DRAINAGEBUILDING M 11,526 S.F.TOTAL = 13,526 S.F.EXISTING BASEMENT WILL BE USED FOR STORAGE FOR NON-HAZARDOUS, NON-ESSENTIAL ITEMS OF LOW VALUE AS ALLOWED BY FEMA TECHNICAL BULLETIN 1.DEMOLISH EXISTING CONCRETE CURBSOUTH BANKF.F.E. : 22'-5"F.F.E. : 26'-5"F.F.E. : 22'-5"BLDG K - LEVEL 1 NEW30' - 5"FLOOD VENT 5W X 1HPAINTED WOOD ABOVEGRADENORTH ELEVATION AT BRIDGE BEYONDASK-005 R13METAL FRAMED WOOD FLOOR26'-8"BLDG K BASEMENT22'-5"B.O. FLOOD VENT26'-11"BLDG K - LEVEL 1 NEW30' - 5"FLOOD VENT 6W X 3H, TYP.BLDG K BASEMENTOXOBOXO BROOK BELOW22' - 5"METAL FRAMED WOOD FLOORCONCRETE SLABB.O. FLOOD VENT23'-00"DateDrawn byScaleREF:1/8" = 1'-0"3/9/2020 4:17:10 PMOXOBOXO LOFTS42 Pink Row Uncasville, CT 06382ASK-005 R13/9/20FLOOD VENT BUILDING KTGBUILDING K1/8" = 1'-0"ASK-005 R11.1/8" = 1'-0"ASK-005 R12..1/8" = 1'-0"ASK-005 R13.BLDG K SEC/ELEV. LOOKING SOUTH UNDER BRIDGEBLDG K -BASEMENT FLOOR PLANBLDG. K PARTIAL WEST ELEVATIONABDECFGHJKLMNORTHSITE KEY PLAN
BUILDING L
877 S.F.
ASK-012
R12
ASK-012
R1 3
(1) 3W X 1H VENT COVERS 600
S.F. PER ATTACHED CHART
SO (2) VENTS ARE NEEDED
F.F.E. : 26'-0"
FLOOD VENTS
3W X 1 H
EL:26'-11"
TO B.O. VENT
FLOOD VENT 3W X 1H
PAINTED P.T. WOOD
PANEL ABOVE PAINTED P.T.
WOOD PANEL
26'-0"
GRADE AND CRAWL SPACE BEYOND
EXISTING WOOD FRAMED FLOOR 29'-7 7/8"
BLDG L-LEVEL 1
DIRT FLOOR
B.O. FLOOD VENT
26'-11"
FLOOD VENT 3W X 1 H
PAINTED P.T. WOOD
PANEL ABOVE
26'-0"
GRADE AND CRAWL SPACE BEYOND
EXISTING WOOD FRAMED FLOOR 29'-7 7/8"
BLDG L-LEVEL 1
B.O. FLOOD VENT
26'-11"
DIRT FLOOR DateDrawn byScaleREF:1/8" = 1'-0"3/9/2020 4:25:57 PMOXOBOXO LOFTS42 Pink Row Uncasville, CT 06382ASK-012 R13/9/20FLOOR VENT BUILDING LAuthor1/8" = 1'-0"ASK-012 R1
1 BLDG L- CRAWL SPACE FLOOR PLAN
A
B
D E
C F
G H
J
K
L M
NORTH
SITE KEY PLAN
1/8" = 1'-0"ASK-012 R1
2 BLDG L EAST ELEVATION
1/8" = 1'-0"ASK-012 R1
3 BLDG L WEST ELEVATION
NOTE: BUILDING L WILL BE USED FOR STORAGE OF
NON-HAZARDOUS, NON-ESSENTIAL ITEMS OF LOW
VALUE AS ALLOWED BY FEMA TECHNICAL BULLETIN 1.
BUILDING M 11526 S.F.
ASK-009
R1
2
ASK-009
R1
FLOOD VENTS
5W X 3 H
EL: 26'-11"
TO B.O. VENT
3
REMOVE EXISTING
EQUIPMENT
NEW SLAB INFILL TO
MATCH LEVEL OF
EXISTING BASEMENT SLAB
(1) 5W X 3H COVER 3000 SF PER ATTACHED
CHART, SO (4) VENTS ARE NEEDED
FLOOD WATER
DRAINAGE
EXISTING BASEMENT WILL BE USED FOR STORAGE
FOR NON-HAZARDOUS, NON-ESSENTIAL ITEMS OF LOW
VALUE AS ALLOWED BY FEMA TECHNICAL BULLETIN 1.
F.F.E. : 22'-5"
F.F.E. :
22'-5"
BLDG K
BASEMENT BLDG K EXISTING DIRT
FLOOR CRAWL SPACE
F.F.E. : 26'-5"
OPEN CONNECTION
BETWEN BLDG K
AND M BASEMENTS
FLOOD VENT
5W X 3 H
EL: 26'-11"
TO B.O. VENT
FLOOD VENT
5W X 3 H
EL: 26'-11"
TO B.O. VENT
FLOOD VENT 5W X 3HGRADE
GRADE
BLDG K
24'-0"
26'- 0"
BLDG K CRAWL SPACE
BLDG K BASEMENT
FLOOD VENTS 5W X 3H
22'- 5"
30'- 5"
BLDG M -LEVEL 1
BLDG K AND M -LEVEL B
METAL FRAMED
WOOD FLOOR
CONCRETE SLAB
B.D. FLOOD VENT
EL : 26'-11"
EL : 26'-11"
B.D. FLOOD VENT
GRADE26'-0"
BLDG M - LEVEL 1 NEW
30'-5"
BLDG M - LEVEL B
22'-5"
METAL FRAMED
WOOD FLOOR
CONCRETE SLAB B.O. FLOOD VENT
EL : 26'-11"
FLOOD VENT 5W X 3H DateDrawn byScaleREF:1/16" = 1'-0"3/9/2020 4:23:46 PMOXOBOXO LOFTS42 Pink Row Uncasville, CT 06382ASK-009 R13/9/20FLOOD VENT BUILDING MTGBLDG M1/16" = 1'-0"ASK-009 R1
1 BLDG M BASEMENT FLOOR PLAN
1/16" = 1'-0"ASK-009 R1
2 BLDG M NORTH ELEVATION & BLDG K SECTION
A
B
D E
C F
G H
J
K
L M
NORTHSITE KEY PLAN
1/16" = 1'-0"ASK-009 R1
3 BLDG M SOUTH ELEVATION
E-2AE-2AE-2AE-2AE-2AD-1D-2D-5D-4BD-3BD-4D-2D-3AD-2D-1UNIT M-1(1 BEDROOM)UNIT M-2(2 BEDROOM)CORRIDORCOATCLOSETCOATCLOSETCOATCLOSETLIN.CLOS.CLOSETBEDROOMCLOSETBEDROOMLINENCLOS.CORRIDORBEDROOMCLOSETKITCHENTYPE 42TOILETTYPE 46TOILETTYPE 45KITCHENTYPE 41D-16"7' - 8"4"3' - 1"4"11' - 10"4"7' - 4"2' - 9"6"2' - 10"7' - 4"4"10' - 8"4"3' - 7"4"6"2' - 2"4"1' - 10"6"18' - 5"4"10' - 1"6"10' - 2"4"3' - 1"6"12' - 10"6"10' - 10"4"2' - 1"4"5' - 1"
1' - 2"
6"5' - 6"6"
6' - 7"6"3' - 8"6"30' - 5"W1W1W1W1W1W1W1W1W1W1W1W5W5W5W5W5W5W5W7AW7AW5W52' - 5"4"1' - 10"4"5' - 2"6"8' - 0"4"1' - 10"4"W7AW7AW5W5W5W5W5W5W5MECH.W5W56"D-2BW5D-3DD-122' - 2"DateDrawn byScaleREF:3/16" = 1'-0"12/26/2019 12:01:33 PMOXOBOXO LOFTS42 Pink Row Uncasville, CT 06382ASK-032r112/23/2019BUILDING M PLAN-LEVEL 1 PART ATGM-A1.4ABDECFGHJKLMNORTHSITE KEY PLANREF: RFI034r1
UNIT M-3(2 BEDROOM)TOILETTYPE 46TOILETTYPE 45BEDROOM 1LINENCLOS.CLOSETCLOSETLINENCLOS.BEDROOM 2COATCLOSETKITCHENTYPE 43BEDROOM 2CLOSETE-2AE-2AE-2AE-2AD-4D-2D-2D-5D-4D-2D-5D-1D-3AD-4D-26' - 7"5"10"2' - 5"4"
4"
2' - 2"W1W5W1W5W5W5W5W5W7AW7AW5W5W5W5W5W5W7AW7AW5W5W5W1W5D-2B10' - 11"4"2' - 1"4"9' - 10"4"10' - 2"6"9' - 7"4"6"MECH.DateDrawn byScaleREF:1/4" = 1'-0"12/26/2019 12:02:39 PMOXOBOXO LOFTS42 Pink Row Uncasville, CT 06382ASK-03312/23/2019BUILDING M PLAN -LEVEL 1 PART BTGM-A1.5ABDECFGHJKLMNORTHSITE KEY PLANREF: RFI034r1
EXISTING MASONRY WALL TO
REMAIN. DRY AND CLEAN OF
DEBRIS, OIL AND GREASE PRIOR
TO APPLICATION OF PRIMER.
NEW GRADE.
NEW PROTECTION BOARD, BUTT-
JOINED AND EXTENDING TO FULL
EDPTH OF EXCAVATION.
NEW FIBERED EMULSION
DAMPPROOFING EXTENDING TO
FULL DEPTH OF EXCAVATION
AND OVER TOP OF FOOTING IF
EXPOSED.
NEW ASPHALT PRIMER.
Date
Drawn by
Scale
REF:
1 1/2" = 1'-0"
12/23/2019 5:34:21 PM
OXOBOXO LOFTS
42 Pink Row Uncasville, CT 06382 ASK-036
12/23/2019
TYPICAL BELOW-GRADE WATERPROOFING
DETAIL AT MASONRY WALLS
SO/SK
Checker
1 1/2" = 1'-0"ASK-036
1 TYPICAL BELOW GRADE WATERPROOFING DETAIL