HomeMy WebLinkAboutTE Comments IP -
IICLA Engineers, Inc.
Civil • Structural • Survey
317 MAIN STREET • NORWICH,CT 06360 • (860)886-1966 • (860)886-9165 FAX
June 16, 2020 II
Ms. Marcia Vlaun
Town Planner
310 Norwich-New London Tpk.
Uncasville, CT 06382
RE: Leemilt's Petroleum
Rt. 82/163 Intersection
CLA-5781Z
Dear Marcia:
We have reviewed the plans submitted for the proposed expansion of the gas
station at 612 Norwich-Salem Turnpike. We have the following comments:
1. The limits of repaving and proposed curbing must be clearly delineated on the
plans.
2. The installation of the walk-in cooler pad appears too close to the septic
system and existing slope to be practical to construct as shown.
3. There is an existing monitor well not shown under the proposed addition.
4. The surface stormwater flow at the southeast corner of the pavement must be
collected and treated.
5. Contact with CTDOT District 2 must be provided regarding access and
drainage.
6. The "no parking" striped area at the SE corner of the site must have the
pavement removed and the area loamed and seeded.
7. The width of the sidewalk must be provided.
8. Proposed spot grades must be shown at the handicap parking area and
handicap ramp.
9. The location of the kerosene dispenser must be reconsidered and placed away
from access to the building.
10. The proposed grading at the dumpster pad must be shown.
11, •
11. The relocation (replacement) of the existing condenser unit in the proposed
cooler location must be shown on the plans.
12. The doors to the building must be shown.
13. The silt fencing or other siltation devices must be shown allowing access to
the site, and at the separator, dumpster and fence installations. Silt inserts
must be provided for the catch basins.
14. The term"refurbish"regarding the existing fencing must be more clearly
defined.
15. The reference to DOT Form must be revised to read 817 in lieu of 816.
Very truly yours,
Tho---------r-
-
as L. Cummings, P.E.
Principal
TLC:bab
From: T Cummings
To: Marcia A.Vlaun;Colleen Bezanson
Subject: Leemilt"s Petroleum Site
Date: Tuesday,July 14,2020 9:40:28 AM
Marcia/Colleen The plans we received yesterday did not address any previous comments, expect
the walkway in
front of the building is shown as 5.0' +or—(?). Tom
Thomas L.Cummings,P.E.
CLA Engineers,Inc.
317 Main Street
Norwich, CT 06360
P: (860) 886-1966
F: (860) 886-9165
tcummings anclaengineers.com
www.claengineers.com