Loading...
HomeMy WebLinkAboutSeptic System Design PlanFILTER FABRIC POST - COMPACTED BACKFILL ---/ PERC TEST DATA TEST HOLE DATA PER SUBDIVISION PLAN PER SUBDIVISION PLAN - (UNCAS HEALTH DEPARTMENT 5/24/18) PERC #2 lv -u KNOCKOUT INLET AND OUTLET OPENINGS PER 1000 S.F. DEPTH - 30" TH #4 0"-8" DARK BROWN TOPSOIL TH #6 0"-6" DARK BROWN TOPSOIL PRESOAK @ 2:15 3:19 - 4 3/8" 8"-48" BROWN MEDIUM SANDY LOAM 6"-39" BROWN MEDIUM SANDY LOAM 3:24 - 7++ 48"-87" TAN SILTY SAND & GRAVEL W/COBBLES 39"-71" TAN SILTY SAND & GRAVEL W/COBBLES/COMPACT 3:29 - 8 7/8" NO LEDGE, REDOX@35", NO GROUNDWATER NO LEDGE, NO REDOX, NO GROUNDWATER 3:34 -101%1" ROOTS TO 55" ROOTS TO 39" 3:39 - 12" TYPICAL SEED MIXTURE: �O TH #5 0"'-8" DARK BROWN TOPSOIL TH #6R V-7" DARK BROWN TOPSOIL 3:54 -15 I/4" 8"-48" BROWN MEDIUM SANDY LOAM 7"-36" BROWN MEDIUM SANDY LOAM 3:59 - 16 1/2" 48"-81" TAN SILTY SAND & GRAVEL W/COBBLES 36"-86" TAN SILTY SAND & GRAVEL W/COBBLES LOT#3 NO LEDGE, REDOX@42", NO GROUNDWATER NO LEDGE, REDOX@36", NO GROUNDWATER 4:09 -18 3/4" ROOTS TO 50" ROOTS TO 52" 4:14 - 19 1/4" b� 00 4:19 - 20" TO jAY IOW �, m IEF, HIS MAP IS SUBSTANTIALLY CORRECT - - 458 - - EXISTING CONTOURS IPIN REC. AS NOTED i` THi �' IS N T VALID WITHOUT A LIVE SIGNATURE --L��- 458 PROPOSED CONTOURS G.• A SEI F HE URVEYOR HEREON. ,A - N 75°16'01"E BUILDING SETBACK LINE : = 1 r,fA f / 150.56' ENGINEER DATE ENGINEER f ° fig € 9 # t # $ v i RICHARD A. DESCHAMPS L.S. #70019 DATE IPIN REC. i i I / I 40' I � i i I I II I I I ! r l I I l II l TH #4 l I I ISI � TH#6R INSTALL & MAINTAIN t A CONTINUOUS LINE OF PROPOSED �1II ILT FENCE (SEE DETAIL I LIMITS OF >i I CLEARING rJi II l 58LF OF GEOMATRIX GST -6212 , ;G�'-2R I EXISTING GRADE @ SYSTEM - 452.0 P 2 BOTTOM OF SYSTEM - 450.60 TOP OF SYSTEM - 451.60 INV. 4" TOP DISTRIBUTION PIPE - 451.60 l } TH#6 l1,250 (2COMP.) TH#5 `- SEPTIC TANK INV. IN -452.25 1 LOT# 1 I INV. OUT -452.00 D O, (SEE DETAIL) -B INv.IN`451.80 N INV. OUT,451.7 l N ill 37LF-411PVC 8LF-4"PVC II (ASTM D1785) (SDR -35) I � l LOT#3 I I I� I DECK o % INV • I W I PROPOSED I I 0. / 4 BEDROOM I / l RESIDENCE (RAISED RANCH) I l F.F.-463.0 I 4 / BSM'T-454.0 FOOTING I DRAIN 115' / _ 4 OUTLET r I ( l ^' ' I I l r i \ I I l I r I PROPOSED ! \ i r \ Ir lWELL PROPOSED / LIMITS OF \ / CLEARING / l / \ PROPOSED Q / \ UTILITIES Q 1 40' \. a II \ •. 1 I 1 \ W 82.04' S 76°15'34" y�r MON 69.06 `. MON 53 S 62°39'" I REC. REC. 452 PROVIDE % 1 -- - BENCHNMARK PAVED NAIL IN POLE APRON ELEV.-457.99 -. CL&P • #6860 WILLIAMS PROVIDE ANTI-TERACKING PAD i� ROAD AD N411 (PER SUBDIVISION PLAN) i CL&P #6861 FILTER FABRIC POST - COMPACTED BACKFILL ---/ PERC TEST DATA TEST HOLE DATA PER SUBDIVISION PLAN PER SUBDIVISION PLAN - (UNCAS HEALTH DEPARTMENT 5/24/18) PERC #2 lv -u KNOCKOUT INLET AND OUTLET OPENINGS PER 1000 S.F. DEPTH - 30" TH #4 0"-8" DARK BROWN TOPSOIL TH #6 0"-6" DARK BROWN TOPSOIL PRESOAK @ 2:15 3:19 - 4 3/8" 8"-48" BROWN MEDIUM SANDY LOAM 6"-39" BROWN MEDIUM SANDY LOAM 3:24 - 7++ 48"-87" TAN SILTY SAND & GRAVEL W/COBBLES 39"-71" TAN SILTY SAND & GRAVEL W/COBBLES/COMPACT 3:29 - 8 7/8" NO LEDGE, REDOX@35", NO GROUNDWATER NO LEDGE, NO REDOX, NO GROUNDWATER 3:34 -101%1" ROOTS TO 55" ROOTS TO 39" 3:39 - 12" TYPICAL SEED MIXTURE: 3:44 - 13" 3:49 - 14 I/4" TH #5 0"'-8" DARK BROWN TOPSOIL TH #6R V-7" DARK BROWN TOPSOIL 3:54 -15 I/4" 8"-48" BROWN MEDIUM SANDY LOAM 7"-36" BROWN MEDIUM SANDY LOAM 3:59 - 16 1/2" 48"-81" TAN SILTY SAND & GRAVEL W/COBBLES 36"-86" TAN SILTY SAND & GRAVEL W/COBBLES 4:04 -17 3/4" NO LEDGE, REDOX@42", NO GROUNDWATER NO LEDGE, REDOX@36", NO GROUNDWATER 4:09 -18 3/4" ROOTS TO 50" ROOTS TO 52" 4:14 - 19 1/4" 4:19 - 20" TO jAY IOW �, m IEF, HIS MAP IS SUBSTANTIALLY CORRECT PERC RATE - 6 MINUTES PER INCH MLSS & DESIGN DATA ANGLE 100 UP SLOPE FOR STABILITY AND SELF CLEANING � x _ Q SILT FENCE NOT TO SCALE 2X2 5 8 16 GA, WIRE MESH 7t 1 1/2"7n STANDARD D -BOX W/ELBOW NOT TO SCALE z N ASTM C-33 SAND SPECIFICATIONS: SIEVE SIZE PERCENT PASSING 0.375" 100 #4 95-100 #8 80-100 #16 50-85 #30 25-60 #50 5-30 #100 <10 #200 <5 kSTM C-33 SAND 4 BEDROOM HOUSE SLOPE -10.8% PERC RATE - 5.1 TO 10.0 MIN./INCH RESTRICTIVE LAYER - 35" M.L.S.S. REQUIRED - 20 x 1.75 x 1.0 = 35' M.L.S.S. PROVIDED - 58' 4 BEDROOM HOUSE REQUIRES 577.5 S.F. OF EFFECTIVE LEACHING AREA USE 58LF OF GEOMTR.IX GST 6212 (58 x 10 = 580 S.F.) USE 1,250 GAL. 2 COMPARTMENT SEPTIC TANK W/ OUTLET FILTER DEVICE RESERVE AREA 58LF OF GEOMATRIX 6212 (58x10=580 S.F.) CAST CONCRETE COVERS PLAN CAPACITIES A B C 1250 GAL 61" 51" 48" 1500 GAL 69" 59" 1 56" 4 x 4 12.6/12.6 GA. WIRE MESH 117 1/2" / Ir-- 6 x 6 6/6 GA. WWyjj H OUTLET CONTINUOUS HOT P ASPHALT SEAL "--4" SCHED. #40 v 1250/1500 GALLON 2 COMPARTMENT SEPTIC TANK NOT TO SCALE FINISH GRADE TO DIRECT RUNOFF AWAY FROM SYSTEM CT DOT =6 STONE :T DOT #6 STONE :kSTM C-33 SAND CROSS SECTION A -A DISTRIBUTION PIPE FILTER FABRIC 6" MIN. H = 6" (GST 6206) b 12" (GST 6212) 18" (GST 6218) 24" (GST 6224) �+ 30" (GST 6230) N ' 36" (GST 6236) - CT DOT #6 STONE SAND CROSS SECTION B -B GEOMATRIX GST LEACHING SYSTEM LEGEND:: lv -u KNOCKOUT INLET AND OUTLET OPENINGS PER 1000 S.F. F -1 F N AND COARSE MATTER EL. ELEVATION L- L� J L /_1 IJ CAST CONCRETE COVERS PLAN CAPACITIES A B C 1250 GAL 61" 51" 48" 1500 GAL 69" 59" 1 56" 4 x 4 12.6/12.6 GA. WIRE MESH 117 1/2" / Ir-- 6 x 6 6/6 GA. WWyjj H OUTLET CONTINUOUS HOT P ASPHALT SEAL "--4" SCHED. #40 v 1250/1500 GALLON 2 COMPARTMENT SEPTIC TANK NOT TO SCALE FINISH GRADE TO DIRECT RUNOFF AWAY FROM SYSTEM CT DOT =6 STONE :T DOT #6 STONE :kSTM C-33 SAND CROSS SECTION A -A DISTRIBUTION PIPE FILTER FABRIC 6" MIN. H = 6" (GST 6206) b 12" (GST 6212) 18" (GST 6218) 24" (GST 6224) �+ 30" (GST 6230) N ' 36" (GST 6236) - CT DOT #6 STONE SAND CROSS SECTION B -B GEOMATRIX GST LEACHING SYSTEM LEGEND:: NOTES PER 1000 S.F. F.F. FIRST FLOOR AND COARSE MATTER EL. ELEVATION AIR DRIED, TREAT WITH S.F. SQUARE FEET SEEDING DATES: APRIL 1------- JUNE 15 TYP. TYPICAL SEED MIXTURE: 45% RED FESCUE x462.5 EXISTING SPOT ELEVATION 10% PERENNIAL RYE FTl InfN } co PROPOSED SPOT ELEVATION e�� �'L= x464.3 TO jAY IOW �, m IEF, HIS MAP IS SUBSTANTIALLY CORRECT - - 458 - - EXISTING CONTOURS AS NOTED i` THi �' IS N T VALID WITHOUT A LIVE SIGNATURE --L��- 458 PROPOSED CONTOURS G.• A SEI F HE URVEYOR HEREON. ,A - BUILDING SETBACK LINE : = 1 r,fA f TEST HOLE ENGINEER DATE ENGINEER f ° fig € 9 # t # $ v - RICHARD A. DESCHAMPS L.S. #70019 DATE EROSION AND SEDIMENT CONTROL PLAN: 1. CLEARING, GRUBBING, AND GRADING OF THE PROPOSED SITE TO BE LIMITED TO AREAS ADJACENT TO THE PROPOSED HOUSE DRIVEWAY AND SEPTIC SYSTEM. 2. DISTURBED AREAS TO BE LOAMED, SEEDED, AND MULCHED, 3. ALL TOPSOIL TO BE STOCKPILED ON SITE AND PROTECTED WITH HAYBALES OR SILT FENCE. 4. ALL CUT AND FILL SLOPES ARE NOT TO EXCEED 3:1 SLOPES. 5. PRIOR TO SITE DISTURBANCE, THE REPRESENTATIVE OF THE TOWN OF MONTVILLE SHALL BE NOTIFIED WHEN SEDIMENT CONTROL MEASURES ARE IN PLACE SO THAT THE INSPECTION CAN OCCUR. 6. THE CONTRACTOR WILL BE RESPONSIBLE FOR THE INSTALLATION AND MAINTENANCE OF ALL REQUIRED SEDIMENT CONTROL MEASURES THROUGHOUT CONSTRUCTION. 7. DUST CONTROL WILL BE ACCOMPLISHED BY SPRAYING WITH WATER, AND IF NECESSARY THE APPLICATION OF CALCIUM CHLORIDE. TEMPORARY VEGETATIVE COVER: MULCHES APPLICATION RATE NOTES PER 1000 S.F. STRAWMAY 70-90 lbs. FREE FROM WEEDS AND COARSE MATTER WOOD CHIPS 185-275 lbs. FREE OF COARSE MATTER AIR DRIED, TREAT WITH PLANTING SCHEDULE: 121bs NITROGEN / TON SEEDING DATES: APRIL 1------- JUNE 15 AUGUST 1------ SEPTEMBER 15 SEED MIXTURE: 45% RED FESCUE 45% KENTUCKY BLUE GRASS 10% PERENNIAL RYE DESIGN NOTES: 1. ALL CONSTRUCTION TO CONFORM TO STANDARDS OF THE CONNECTICUT PUBLIC HEALTH CODE AND TO THE SATISFACTION OF THE TOWN SANATARIAN. 2, THIS SYSTEM HAS NOT BEEN DESIGNED FOR THE USE OF LARGE CAPACITY (+100 GALLONS), DISCHARGE TYPE BATHTUBS. RESIDENTIAL GARBAGE DISPOSALS ARE NOT ANTICIPATED FOR THIS DESIGN. IN THE EVENT THAT SUCH AN INSTALLATION IS CONTEMPLATED FOR THE PROPOSED HOUSE, A LARGER SEPTIC TANK AND INCREASED LEACHING FIELD CAPACITY WILL BE REQUIRED, LEACHING SYSTEM CONSTRUCTION NOTES: 1. TOPSOIL TO BE STRIPPED OFF PRIOR TO FILLING. FILL MATERIAL BETWEEN AND BEYOND TRENCHES TO BE PERVIOUS, GOOD QUALITY AND CLEAN MEDIUM SAND (SELECT FILL) PLACED AND COMPACTED IN 6" LIFTS. SELECT FILL SHALL MEET THE FOLLOWING MINIMUM REQUIREMENTS: A. THE FILL SHALL NOT CONTAIN ANY MATERIAL LARGER THAN 3 INCHES, B. THE FILL SHALL NOT CONTAIN MORE THAN 45 PERCENT GRAVEL (GRAVEL IS BETWEEN NO.4 & 3" SIEVES) NO MORE THAN 45 PERCENT OF THE MATERIAL CAN BE RETAINED ON THE NO.4 SIEVE. C. THE FILL LESS THE GRAVEL SHALL MEET THE FOLLOWING GRADATION CRITERIA: SIEVE SIZE: #4 #10 #40 #100 #200 % PASSING: 100 70-100 **10-50 0-20 0-5 WET SIEVE %PASSING: 100 70-100 10-75 0-5 0-2.5 DRY SIEVE ** PERCENT PASSING THE #40 SIEVE CAN BE INCREASED TO NO GREATER THAN 75% IF THE PERCENT PASSING THE #100 SIEVE DOES NOT EXCEED 10% AND THE #200 SIEVE DOES NOT EXCEED 5%. 2. DOCUMENTATION OF TEST RESULTS ARE TO BE PROVIDED TO THE HEALTH DISTRICT. 3. FILL MATERIAL TO BE PLACED PRIOR TO TRENCH EXCAVATION. NO TRAFFIC OTHER THAN TRACK -DRIVEN EQUIPMENT IS TO CROSS, DUMP, UNLOAD OR OTHERWISE COMPACT THE FILL AREA AFTER TOPSOIL REMOVAL. FILL MATERIAL TO BE DUMPED AT THE EDGE OF THE STRIPPED AREA AND SPREAD AND COMPACTED WITH TRACK -DRIVEN VEHICLES. STOCKPILING IS TO TAKE PLACE UPGRADIENT OF THE LEACHING AREA, THE AREA DOWN GRADIENT OF THE LEACHING AREA IS NOT TO BE DISTURBED. SEPTIC SYSTEM CONSTRUCTION NOTES: 1, CONSTRUCTION SEQUENCE: A. STRIP & STOCKPILE TOPSOIL FROM LEACHING TRENCH AREA, B. PLACE SELECT FILL TO 8" BELOW EXISTING GRADE.(IF REQUIRED). C. CONSTRUCT LEACHING TRENCHES TO DESIGN LINE & GRADE. D, LOAM, FINE GRADE TO FINISHED GRADE AND SEED. PROTECT DISTURBED AREAS WITH EROSION CONTROLS UNTIL FIRST MOWING. 2. THE PIPE BETWEEN THE HOUSE AND SEPTIC TANK SHALL BE 4 IN. EXTRA HEAVY CAST IRON, DUCTILE IRON OR EXTRA STRENGTH PVC ASTM D 1785 SCHD 40 OR APPROVED EQUAL. �• ALL DISTRIBUTION PIPE IS TO BE ASTM D3034 SDR 35 (4"PVC) OR APPROVED EQUAL UNLESS NOTED. 4. SEPTIC TANK SHALL BE SET LEVEL ON A MINIMUM OF 6" OF PROCESSED GRAVEL OR BROKEN STONE ON COMPACTED SUBGRADE. 5. THERE ARE NO APPARENT WELLS OR SEPTIC FIELDS WITHIN 75' OF THE PROPOSED WELL AND SEPTIC SYSTEM AS SHOWN ON THIS PLAN. 6. APPROVED STONE AGGREGATE FOR LEACHING TRENCHES SHALL BROKEN STONE, CRUSHED STONE, OR SCREENED GRAVEL MEETING CT DOT FROM 814A SPECIFICATION FOR M.01.01 FOR NO, 4 STONE: SIEVE SIZE PERCENT PASSING (BY WEIGHT 2 -INCH 100 1 -1/2 -INCH 90-100 1 -INCH 2O-55 3/4 -INCH 0-10 3/8 -INCH 0-5 7. THE LOCATION AND ELEVATION OF THE PROPOSED SEPTIC SYSTEM SHALL BE STAKED IN THE FIELD BY A LICENSED LAND SURVEYOR. NOTES: 1. TOPOGRAPHIC INFORMATION ON THIS PLAN COMPLIES WITH T-2 MAPPING STANDARDS. 2. PROPOSED HOUSE AND SEPTIC SYSTEM TO BE STAKED IN THE FIELD BY A LAND SURVEYOR LICENSED IN THE STATE OF CONNECTICUT. 3. BASE FOR LEVELS: PER SUBDIVISION PLAN, 4. THE PROPERTY IS LOCATED IN ZONING DISTRICT - R-40. 5. THERE ARE NO WELLS LOCATED WITHIN 75' OF THE PROPOSED SEPTIC SYSTEM LOCATED ON ABUTTING PROPERTIES. 6. TOTAL AREA OF PROPERTY - (0.97 ACRES 7. A BENCHMARK IS TO BE PLACED WITHIN 50' OF THE PROPOSED HOUSE & SEPTIC SYSTEM AT THE TIME OF CONSTRUCTION. 8. ALL UNDERGROUND UTILITIES SHOULD BE MARKED OUT PRIOR TO THE START OF CONSTRUCTION. REFERENCE MAP: RESUBDIVISION PLAN - CONCEPTUAL DEVELOPMENT PLAN PREPARED FOR GNN HOLDINGS, LLC, 70 WILLAMS ROAD. MONTVILLE (OAKDALE) CONNECTICUT, SCALE: 1"=40', DATE: JUNE 2018, REV. TO 8/20/18, PREPARED BY BOUNDARIES, LLC.