Loading...
HomeMy WebLinkAboutPlot Plan24d L07 V7AC /0,4 1A 1 MAP\C A E)RIVE- (UNDEP CO\,iTRUC'.710\) 34 121 0 0, 0 0 r/ 74 4 1 5' 232 P R 0 P 0 E D-, D W E LL 0. I N 30 1XIIz4DRAIN1+0 25-4 - C I P 242 1250 G A 0 S PTIC TK z INV. 2- 5S.50 IN I Iv.235.250UT n ri z 0 LL_ 4" SOLID WALL PVC OVERFLOW DtSTRORUTION INV 2 34,40 — IN INV 234.23 —OUT(SCE) INV 2.34.53 — OVERFLOW 4/ SOLID WALL PVC OVERFLOW DISTRIBUTION 150X- INV 232,40—IN INV L32.23-- OUT(SIDE) INV 232.53 — OVERFLOW 4" SOLID WALL PVC DISTRIBUTION BOX— INV 230.40 IN INV 230-23— OU -T ox, Z L C\j LO 1\77) V, , A N T i L-0 SANITARY PLOT PLAN LOT #!i - GREYSTONE ESTATES PREPARED FOR STEPHEN & LYNN CHURCH 6 UNCAS COURT QUAKER HILL, CT PREPARED BY GARY WINALSKI CIVIL ENGINEER scale 11' =20ft sheet 15f2 8" MINIMUM OF TOPSOIL OIZ F-4 FERTILIZE, SEED AND MULCH) Z" SALT HAY OR UNCOATED BUILDING PAPER A A v 4 0 4" DIA. PERFORATED P.V.C. PIPE 34 -4 — — ---- — — — — — 4 A 4 6 A 11 1" CRUSHED STONE12 LEATRENCH DETAILCHING; N.T. S. 5 DIA-10UTLET KNUU GROUT ALL jONTS 5"'i)IA. INLET KNOCKOUT FOR 4" PIPE FROM SEPT'1C TANK-) SIDE OUTLETS TO LEACHING TRENCHES END OUTLET OVERFLOWS TO LOWER DISTRi6urnON BOX THRU 900 BEND TURNED UP. ARD PRECAST DISTRIBUTION BOX HIGH LEVEL OVERFLOW DETAIL N. T. S. LEGEND_ existing contour proposed contour proposed spot grade cast iron pipe 4 monument stone NOTES 1. Boundary information from plan entitled "PHASE I, LOTS 1 THRU 15, & LOT 27 GREYSTONE ESTATES SUBDIVISION, PROPERTY OF GREYSTONE ASSOCIATES, OLD COLCHESTER & MOXLEY T IROAD, MONTVILLE, CONNECTICUT, SCALE 111 = 100 1 SEPT. 29, 1987, DICESARE-BENTLEY ENGINEERS, INC., GROTONT L4 CONNECTICUT 2. Elevations based on top of monument stone (M. S.) to be set by Dicesare-Bently Engineers on south-west corner of Lot #5. 3. Deep Test Hole and Percolation Test information from Dicesare-Bently Engineers and this data was used for the design of the septic system on this property. 4. Topsoil shall not be stripped from the septic system area. Remove vegetation by working parallel to the proposed leaching trenches. 5. Fill placed within fifteen(15) feet of leaching trenches shall be clean select granular soil suitable for septic system installation. SANITARY DESIGN CRITERIA 1. Percolation Rate: 5.7 minutes per inch 18"(hole dug 7/29/87) 2. Design: 4-bedr6om h01ne with basement 3. Required Leaching Area: 660SF area 3 rows 3f wide trenches 74ft long 666SF4, 100% Reserve Area Provided 6. Deep Test Hole=Data (h'o'le dug 9/10/87) Off to 71' topsoil 71, to 29" yellow/brown fine sandy loam, some boulders 29" to 61" pale yellow loamy silt 61" to 941, gray very firm sandy till some boulders no ledge encountered no mottling encountered no groundwater encountered roots extended to 52" SANITARY PLOT PLAN os LOT#5-GREYSTONE ESTATES PREPARED FOR STEPHEN & LYNN CHURCH 6 UNCAS COURT QUAKER HILL, CT PREPARED BY 71 GARY WINALSKI CIVIL ENGINEER sheet 2of2