Loading...
HomeMy WebLinkAboutPlan5/28/97 & 5/29/97 TH#10 0"-9" TOPSOIL TH#117 0"-16" TOPSOIL TH#118 0'-20' TOPSOIL 9'-22" SUBSOIL 16'-34" SUBSOIL 20'-36" SUBSOIL 22'-86" SANDY TILL 34'-84' SANDY TILL 36"-90' SANDY TILL MOTT. @ 22' MOTT. @ 36' MOTT, @ 36" NO WATER NO WATER NO WATER NO LEDGE NO LEDGE NO LEDGE PERC TEST DATA MLSS CALCULATIONS FOR 5/28/97 & 5/29/97 3 BEDROOM HOUSE TH#119 0"-15" TOPSOIL 15"-36" SUBSOIL 36'-90' SANDY TILL MOTT. a 36" NO WATER NO LEDGE LOT#7 MLSS REQUIRED PROPOSED DEPTH - 38' (HF) (FF) (PF) 225 LINEAR FEET PRESOAK @ 1350 42' X 1.5' X 1.5' = 94.5 FT. REQUIRED TRENCHES 2330 - 4 3/4' 105.5 FT, PROVIDED 2340 - 7' w 2350 - 8 3/4' MIN. UNIFORM 3 BEDROOM 3300 - 10' PERC. RATE HOUSE 3310 - 11' Copies of this map are not valid without a live 3320 12' 10.1 - 20 MIN, = 675sq.ft. 3330 13' PROPOSED 1' - 10 MIN.) 225' X 3 _ 675sq.ft. NOTE, Test hote and Perc test data shown were obtained from the plan entitled, 'Subdivision Plan, Stony Brook Acres, prepared for William M. Hracyk & Anne M, Doniewicz, Salem Turnpike (RTE 82), Cherry Lane & Noble Hill Road, Montville, Connecticut', dated, April 24, 1997, last revised 8/1/97, by Chandler, Palmer, and King. NCH MARK DOUBLE C.B. LOT 14-6 Land N/F o Joshua A. nd [-)okin M Zuckerman IAI DISTRIBUTION BOX WITH HIGH LEVEL OVERFLOW DETAIL A NOT TO SCALE LOT 14-7 a Land N/F o Kenneth T BENCH MARK TOP OF IRON PIPE EL. 361.98 350 and Trud Greenwood I N11 111 Area=3,4Ac, originala grade topsoil layer INSTALL SILT FENE\ PRIOR TO EXCAVATI _ \. FO IMG AND SITE WORK* AIN OUTLET A, `40 w ,4 qt ET ass TW 117 \ 5 FT FS T'U,,DRAIN ®UTLE BURIED ELECTRIC,, PHONE, AND NN 3 .38 x 1 `\ ` t LORI ANN DRIVE CABLE TV INSTALLED IN CONDUIT TN 1 8 FT L=9818' OFFSET 9. R=60,00 ERF Delta- 93°45`24 '' ' INSTALL SILT FENCE w . , PRIOR YO EXCAVATION \ Ch= S 2 6 06 82 W o L0 7 PROPOSED HOU 2 AND SITE WORK87,5 9' TOP OF FOUNDATIONiEL. 368.5 L BOTTOM OF FOOTING C NK\ EL. 360.0 r ; 7.$5 358.98 -Box wr ' H LEVELIrOW 368.2 t.3 x RAISE MANN TH119 \ I -r TO GRADE \ 367.7 x 9. \ 1 RAGE 0 3, \\\, x S \`w OP, -,OF FOUNDAR Monument found -- — ~' 1 _ L. 3#8.5 it TRENCH"A" 3' :7 x ]FINISHED FLOOR, Exi tin dirt pile \ C_ ds 367.8`\ \ 364 X368.9. PL-\4STIC WATER\ P s I SERVICE 366 BUILDING LIFE o PROPO D WELL..,,, o OCATION 368 , 4 37v ' • ` aIronpinfound10.0372 \ S89°00'00"W --4-- 380x 358.78613,6 6' 360 l I 350 370 J 8 0 LEGEND EXISTING ELEVATION X PROPOSED ELEVATION HOUSE SEWER INVERT = 362.0 SEPTIC TANK INVERT IN = 361.4 SEPTIC TANK INVERT OUT = 361.15 TRENCH 'A' FLOW LINE 358.17 D -BOX HIGH LEVEL OVERFLOW = 358.27 TRENCH 'B' FLOW LINE _ - 357.42 SEPTIC SYSTEM ELEVATION SCHEDULE To my knowledge and belief, this map is substantially cn_. rri?ct. as noted hereon, dX r LOT 14-8 Land N/F of' PauL Jr and Jean M Bigelow LOCATION MAP TRENCH'A' FLOW LINE EL. 358.17 TRENCH'B' FLOW LINE EL, 357.42 TOP OF MIN.6" COVER EMBANKMENT 5/EL, 358.0 10' rein P VV7P-4-7vVv7 s PS YiT S' P49FP SELECT FILL MATERIAL L4.- 18" rein, MOTTLING ELEVATION 22' BELOW EXISTING GRADE NOTE, STRIP OFF TOPSOIL TO THE SUBSOIL LAYER AND FILL WITH SELECT MATERIAL AS INDICATED SE r T I 171 KI _A GENERAL NOTES= To My kngwi" e,,and belief, this map R Is subs #Gt(". txf-, ^ect as noted hereon. No. 8132 A P,ti..y V i.. 6 4 a. . r 6gcK=a\f..: Y•=' 6V r"°°Y s .c.'u. ,.-:rir ..a NOT TO SCALE 1, The current owners of record of lot #14/7 as w shown are, Kenneth and Trudy Greenwood, 2, The typical building line setbacks for this lot are; front 50', sides 20', and rear 50'. 3, Said lot is not in a flood plane, 4, Copies of this map are not valid without a live signature and embossed seal of the licensed Z professional(s) shown below. CONSTRUCTION NOTES, 1, Silt fence shaft be installed prior to commencing site work. 2. After the fill is placed and compacted, v, it Must be pert tested prior to installation of the septic system. 3. All topsoil shatt be stockpiled and H saved for tandscaping, 4, It will be teh septic installer's responsibility to follow regulations of the CT Public Health Code, 5, CALL -BEFORE -YOU -DIG shall be notified Ill by the excavation contractor prior to starting work. 6. Consideration was given to passive solar design, however because of existing topography, it was necessary to locate the garage on the south western side of the house. Some windows W were ommitted on the north side of the house. SURVEY NOTES, 1, This survey has been prepared pursuant to the Regulations of Connecticut State Agencies Sections 20-300b-1 through 20-300b-20 and the 'Standards for Surveys and Maps in the State of Connecticut' as adopted by the Connecticut Association of Land Surveyors, Inc. on September 26, 1996; eo This topographic survey is a resurvey done to Class A-2 horizontal accuracy, and T-2 vertical accuracy, and done in January 1999. 2. Bearings and distances shown are based upon a map entitled, 'Subdivision Plan, Stony Brook Acres, prepared for William M. Hracyk & Anne M. Daniewicz, Satem Turnpike (RTE #82), Cherry Lane & Noble Hill Road, Montville, Connecticut', scale, 1'=50', dated: April 24, 1997, last revised 8/1/97, by Chandler, Palmer, and King. 3. Vertical datum is based upon a proposed elevation of 368,65' on the existing double type 'C' catch basin at the end of the cut -de -sac, as shown on map file 1524, sheet 5 of 7, on file in the Montville Town Halt. 4, The septic trenches have been staked in the field on March 1,?4y ,1999, and the house corners shot( bestoked/ 1'T ds i i+ nil + a,. A .9 , 9`=• k -R. _X.. : rl iPCO e --:a,9 4 -tebe V Z W Y Drawn: KTG Date= 2/11/99 Revised: 3/16/99 Unces Health District Comments SCALE 1# = 20' PROJECT NORTH w z Z W U z z QZQo H' v, H O I I WIn/ L L I J J Ill J H Hti W F -OO Drawn: KTG Date= 2/11/99 Revised: 3/16/99 Unces Health District Comments SCALE 1# = 20' PROJECT NORTH