Loading...
HomeMy WebLinkAboutPlanA iuKNFILI NOT TO SCALE 2"X2"X48" WOOD POST I08 ON CENTER (MIN)INDUSTRIAL NETTING, SNOW FENCE OR WOVEN WIRE FENCE FOR SUPPORT SmIxamm"T. LEGEND AND ABBRb ON5 EX15TINC4 CONTOUR 511 PROPOSED CONTOUR 5015 + PROP05LO SPOT GRADE SCLC BITUMINOUS CONC121ETE UP CURB BCLC BUILDING 5ETBACL LINE BSMT BA,5EMENT Cb CATCH BA51N CIP CAST IRON PIPE ID — BOX DISTRIBUTION Box ELEV ELEVA-11ON EXIST FX,1517INC4 FF FINISHED FLOOR FT FEET DARK BROWN TOPSOIL PERCOLATION RATE AT 24" DEPTH = 8.0 MINUTES/INCH 13 INLAND WETLAND FLAG LOCATION AND NUMBER INV INVERT LF LINEAR FEET MIH MINIMUM PROP PROPOSED PVC POLYVINYL CHLOPIDE PIPE RCP REINFORCED CONCRtTf_ PIPE S SLOPE 5AH 5ANITAR), 5F 5QUARE FEET TF TOP OF FRAME TYP TYPICAL TP#93 DEEP TEST PIT LOCATION AND NUMBER P- eA PERCOLATION TEST LOCATION AND NUMBER DUE TO DISTORTION DURING, REPRODUCTION, TH15 PRINT MAY NOT SCALE EXACTLY ALL DIMENSIONS SHOWN 0Vf.PQULt SCALING- IF THERE ARE ANY DISCREPANCT-5, CONTACT ENC.INEEQ. TP #93-#94 WERE DUG ON 10--27-88 AND WERE WITNESSED BY WENDY MIS OR CONNIE DINERMAN OF THE UNCAS HEALTH DISTRICT TP #120-#122 WERE DUG ON 1-8-91 AND WITNESSED BY CONNIE DINERMAN OR RAY ANDREWS OF THE UNCAS HEALTH DISTRICT PERCOLATION TESTS PERFORMED ON 5-24-91 TP 93 TOPSOIL 10" — 28" 0" — 7" DARK BROWN TOPSOIL GREY—BROWN FIRM FINE SILTY SAND 7" — 34" ORANGE BROWN VERY STONY SANDY LOAM WITH GRAVEL TP #122 34" — 91 TAN MODERATELY COMPACT COBBLY FINE SANDY LOAM WITH SOME GRAVEL 12" TOPSOIL 12" — NO LEDGE, NO GROUNDWATER, MOTTLING AT 24" TP 94 92" GREY—BROWN FIRM MEDIUM—FINE SILTY SAND, TRACE OF GRAVEL 0" — 5" DARK BROWN TOPSOIL PERCOLATION RATE AT 24" DEPTH = 8.0 MINUTES/INCH 5" — 34" ORANGE BROWN VERY STONY SANDY LOAM WITH SOME GRAVEL 34" 85" TAN MODERATELY COMPACT FINE SANDY LOAM WITH SOME GRAVEL NO LEDGE, NO GROUNDWATER, MOTTLING AT 27" TP 120 0" 12" TOPSOIL 12" 32" LIGHT BROWN FINE SANDY LOAM 32" 95" GREY—BROWN FIRM FINE SILTY SAND NO LEDGE, GROUNDWATER AT 29", MOTTLING AT 29" TP 121 11 11 0 0 — 10 TOPSOIL 10" — 28" LIGHT BROWN FINE SANDY LOAM 28" — 90" GREY—BROWN FIRM FINE SILTY SAND NO LEDGE, GROUNDWATER AT 27", MOTTLING AT 27" TP #122 LAJ II U V) 0" — 12" TOPSOIL 12" — 30" LIGHT BROWN FINE SANDY LOAM 30" — 92" GREY—BROWN FIRM MEDIUM—FINE SILTY SAND, TRACE OF GRAVEL NO LEDGE, GROUNDWATER AT 28", MOTTLING AT 28" P -8A PERCOLATION RATE AT 24" DEPTH = 8.0 MINUTES/INCH P -8B PERCOLATION RATE AT 28" DEPTH = 6.0 MINUTES,ANCH INLAND vvtTLAND5 K agy QL51 b Q .I'LLRIA PROPOSE[) 4 H[4*00M 1-100't ISE SiGN PERE SLA rION RATE 1 10,0 MINIJTE'/ING.H LEACHINC-0 AREA REQUIRED 660 CSF` EFFF('TIVF DESIGN, GALI ON SFPTI(,, TANI,( WITH Rows OF 8,75 LF (TOTAL 175) OF 16" HIGH PLASTIC LEACHING INFIL TR. A TORK-, LEACHING AREA PROVIDED I-) x 87.5 LF x 3.8 SF/LF = 665 SF EFFECTIVE 1009 RESERVE AREA PROVIDED AImp& RNWAU4 iL55) CALCUL4110N DEPTH TO RESTRICTIVE LAYER = 27" HYDRAULIC GRADIENT = 6,7± % HYDRAULIC FACTOR (HF) = 28 FLOW FACTOR (FF) FOR 4 BEDROOMS = 2.0 PERCOLATION RATE = 8.0 MINUTES/INCH PERCOLATION FACTOR (FF) = 1.2 MLSS = (HF) x (FF) x (PF) = 67.2' LEACHING SYSTEM SPREAD PROVIDED = 87.5' F510 V1_ 10 CB#6A TF 512.03 INV 500.93 5141 C) LJ( U Ld ( U CO 1. REFERENCE IS MADE TO PLANS TITLED: Li A PLAN SET: "LOCHDALE ESTATES PROPERTY OF BERNARD BARNETT & HAROLD U p D. BATT FOR PROPERTY LOCATED AT- FORSYTH ROAD AND JEFFREY MANOR C> DRIVE MONTVILLE, CONNECTICUT JANUARY 1992 JOB NO. 87-4-80" BY 6 cl-, TOTAL TECHNOLOGY, INC. REVISED TO 7/9/92. WayJZ LOT LAYOUT PHASE I LOCHDALE ESTATES PROPERTY OF BERNARD BARNETT c HARULU 3 _J D. BATT FORSYTH ROAD AND JEFFREY MANOR DRIVE MONTVILLE, CONNECTICUT" co > SCALE 1" = 100DATE FEBRUARY 1993 BY TOTAL TECHNOLOGY, INC, wOjz' 10NO2. ELEVATIONS BASED ON NATIONAL GEODETIC VERTICAL DATUM (NGVD). fS 3. ALL UTILITIES ARE APPROXIMATE. CONTRACTOR TO VERIFY ALL UTILITIES LOCATION AND ELEVATION) PRIOR TO CONSTRUCTION. CONTRACTOR SHALL ONTACT "CALL BEFORE YOU DIG" AT 1-800-922-4455 AT LEAST 72 HOURS RIOR TO ANY EXCAVATION. w zA 4. HIS SITE IS LOCATED IN AN R-40 ZONE. g, 5. '-OR EXACT HOUSE DIMENSIONS, SEE BUILDING PLANS. m6.1 TE PREPARATION PROCEDURE FOR THE INSTALLA11ON OF THE NEW SEWAGE tk iSPOSAL SYSTEM: z STRIP ALL TOPSOIL, VEGETATION AND ORGANIC MATERIAL IN ARE *,,-OF 5 FEET SURROUNDING NEW PRIMARY LEACHING INFILTRATORS. WmU, PLACE AND COMPACT SUITABLE FILL MATERIAL (CLEAN BANK RUN GRAVEL) IN 12 INCH LAYERS IN THE AREA OF THE PRIMARY LEACHING INFILTRATORS UP TO & AT LEAST THE ELEVATION OF THE TOP OF THE INFILTRATORS. SUITABLE FILL MUST HAVE A PERCOLATION RATE OF 10.0 MINUTES/INCH OR FASTER TO BE ACCEPTABLE AFTER PLACEMENT AND COMPACTION. IF FILL IS UNACCEPTABLE, IT MUST BE REMOVED AND REPLACED WITH SUITABLE FILL. INSTALL SYSTEM PER PLAN. COVER SYSTEM WITH 12 INCHES OF LOAM, GRADE TO PREVENT PONDING AND SEED WITH GRASS TO STABILIZE. THE FINAL GRADE 15 FEET FROM THE LEACHING INFILTRATORS SHALL BE AT LEAST THE SAME ELEVATION AS TOP OF THE RESPECTIVE LEACHING INFILTRATORS, THE- BLASTING OF LEDGE IS STRICTLY PROHIBITED IN ARES ,F THE NEW SEPTIC SYTEM. 7. DTIC. SYSTEM INSTALLATION SHALL CONFORM TO THE CURRENT111TION /REVISION OF THE -PUBLIC HEALTH CODE OF THE STATE OF k-)NNECTICUT" BY THE STATE OF CONNECTICUT DEPARTMENT OF HEALTH t_PVICES, ALL MATERIALS (PIPING, SEPTIC TANK, STONE, FILL) USED FOR E SEPTIC SYSTEM SHALL CONFORM TO THE CURRENT EDITION /REVISION OF THE ECHNICAL STANDARDS FOR THE DESIGN AND CONSTRUCTION OF SUBSURFACE WAGE DISPOSAL SYSTEMS". 8. OPOSED HOUSE SEWER SHALL BE CAST IRON PIPE OR APPROVED EQUAL. ALL Itk HER SEWER PIPE FOR THIS SEPTIC SYSTEM SHALL BE 4" PVC ASTM D3033 OR 3034 WITH RUBBER COMPRESSION GASKET BELL AND SPIGOT OR APPROVED UAL. C Oil DEVIATION FROM THE APPROVED DESIGN PLAN SHALL BE ALLOWED WITHOUT LOIORAPPROVALFROMTHEUNCASHEALTHDISTRICTANDDESIGNENGINEER. P_ 2 V 0 00 F -- z 0 z 0 CL I-) LAj 1#7 151 PVC 504.70 500.82! > UAJTF INV 500 58(r4 INV 500.00(w,, INV 499 75 , (E) 1995 TOTAL TECHNOLOGY INC, UJ These drawings are the property of the Eng"er and have been specifically prepared for the owner of tFws project, at this sate, and are not to be duplicated or used jv in port or whole for any other purpose, project, locotson or owner without the expressed written consent of the Eng"er. 60' C13*613 TF 512.03 INV 5013.71(N ) INV 507 OO(W) INV 507-00(t) 20 0 ;u 40 60 1 T05 MAP 15 COMPILED FROM OTHER MAP5, DEED D1MF_N510N5 Atl,,D OTHER 5OURCE5 OF INFORMAnON, NOT TO BE CON5TRUF_D GRAPHIC 5CALE IN FEET KliAN ACCURATE 5URVEY AND 5UBJECT TO FINAL CHANC4f-5 9CHECKBEFOREU51NC4) Att" A MORE ACCURATE SURVEY MAY D15CLO5E. J OF Q) Z zLAJII U V) z 3 I C=k Li J 0 UJ U 1JCV U 0 13.707 z lLJ UJ C) U n ILI it U 0 1C) J OF