HomeMy WebLinkAboutSketch2„
x.25„
x.25"
I Lit Q quilt
FILTE n. FAunic
12 to
0 1 D LESIDE L'i' S, D F I N Fl LTR,VTOP SECT,
6.75"
THE STANDARD INFILTRATOR'
No Scale
Nr TA
L(5r Pte'
I nI SF
r-•- . c ... `r 'tom
5p2
INDUSTRIAL NETTING, SNOWFENCEORWOVENWIREFENCE2"x2"x48" WOOD
POLEL
FOR SUPPORT.
I TER FABRIC
NATIVE SOIL
LL
I 41-77%
5r -
SANITARY ELEVATION DATA -- -
GE'' D -
O SANITARY INVERT AT FOUNDATION: 509.50
PERTY LINE - I C-
20 44'-4" DIA SCHEDULE 40 ASTM D 1785 OR EQUAL PIPE
MIN SLOPE = 1/4" PER FT) •' ' EET LINE - --
D 1250 GALLON TWO COMPARTMENT SEPTIC TANK
DING SETBACK. LINE INV. 508.50 IN
INV. 508.25 OUT PERCOLATION TEST P10 -C (RECORDED BY GARY WINALSKI ON 517, 02)
TING CONTOUR ,/ HOLE DUG TO A 25" DEPTH
40 60'-4" DIA SDR 35 PVC PIPE 12" PRESOAK AT 11:15 AM
11'
OSED CONTOUR 12" REFILL AT 1:00 PM
5 MODIFIED HIGH LEVEL OVERFLOW' "D" BOX
INV. 507.62 IN TIME READINGTESTPITLOCINV. 507.45 TO INFILTRATOR
INV. 507.70 OVERFLO'vV 12:45 11 1/2"
TEST LOC-
O 15'-4" DIA SDR. 35 PVC PIPE 12:55 13"
AND BOUNDARY "' O "D" BOX 1:05 14"
INV. 507.07 IN
INV. 506.90 OUT 1:15 14 3/4" NG (COMPLIANCE TABLE
REQUIRED PROVIDED 43.75' LONG x 12" SIDE x SIDE INFILTRATOR
I $ CJ6
1:25 15 1/2"
r YARD Sy, ;TBACK 50 60'BOTTOM OF INFILTRATOR ELEV: 5 C 6. -
INFILTRATOR INV: 507.4 8 506.90 9 1:35 16 1/4"
YARD SETBACK 15' 102'
MIN PERC RATE: 13.33 MIN/INCH
MODIFIED HIGH LEVEL
OVERFLOW " D" BOX
NOT TO SCALE
E
160V
IFF. FF.
G,
DEEP TEST PIT DATA
TP #95 (10-27-88)
0-6" DARK BROWN TOPSOIL
6-75" ORANGE BROWN LOAM WITH SOMI; SALT AND GRAVEL
75-87" TAN MODERATELY COMPACT, COBBLY FINE SAND & GRAVE
NO LEDGE, GROUNDWATER @ 46", MOTTLING AT 26"
TP #96 (10-27-88)
0-5" DARK BROWN TOPSOIL
5-28" ORANGE BROWN SANDY LOAM WITH GRAVEL
28-85" TAN MODERATELY COMPACTCOBBLY FINE SANDY
LOAM AND GRAVEL
MOTTLING AT 22", NO LEDGE, GROUNDWATER AT 84"
TP #125 (1-8-91)
0-12" TOPSOIL
12-42" LIGHT BROWN FINE SANDY LOAM
42-90" GREY -BROWN MEDIUM -FINE SILTY SAND, TRACE OF GRAVE
NO LEDGE, GROUNDWATER AT 36", MOTTLINrTG AT 30"
TP #126 (1-8-91)
0-10" TOPSOIL
10-33" LIGHT BROWN FINE SANDY LOAM
33-90" GREY -DROWN MEDIUM -FINE SILTY SAND, TRACE OFGRAVEL
NO LEDGE, GROUNDWATER AT 33", MO's TLING AT 26"
PERCOLATION TEST DATA
P- 10 A 6.0 MINifNeff, 24" DF_FffI(06-2( -91)
P- 10B 12.0 MIN/INCH, 24" DEPTH (06-20-91)
LOCATING D1M. F S10, S
FDN C.C. 1Z.I, I: I
FDN CORNER,
t)" 13OX0
WI_l"L L LOC'
x1S7)KiG
IN
1p7 9 5
GENERAL NOTI•: 4 CO..NTINUED
9. PRIOR TO 1-1 IE . JT RT OF CONSTRUCTION TEST HOLES'"W ", "X", "Y> & "Z" ARE TO BEDUGANDW1"1"1,'Sf:D BY THE UNCAS HEALTH DISTRICT.'
10. AFTER FILL. IS Pi.ACF:D AND COMPACTED, IT MUST BE PERC TESTED PRIOR TOINSTALLATIONofTLIESYSTEMBYTHEUNCASHEALTHDISTRICT.
1 BMX
INSPECTION OPENING
MAt 11-IOLE MANI1G1_E
1 8'
7 --,-
144'
INLET
77'
2-
INLET BAFFLE MIN. OUTLET FILTER
DEVICE
LIQUID J.
2/3 REQUIRED DEPTH
CAPACITY 1/3 REQUIRED
f , CAPAC I iY
LENGTH NOT GREAIER THAN
4 TIMES WIDT}-1 OR DEPTH
y ,-' I . , , TIC TANKT1Itl1 `
NOTE. CLIJ-J"ITUT kjtjjt (uL. S MD AL_ BAFFLED
It,,,: L+:Tivty m,,rttiOL.`S SHALL L3C LOCATE
AT A oEPTH NOT GREATER TI1AN 12- BELOW
FINAL GF AC)E.
APPENDIXNIX B
I I g?0%1"1:1 "Is"IC`T.s.t tl.
0 u 1
ro
O.C 0 SYSTRI'viS FJ Q 14-3 6
TROIL-13'1'
TUB'-TITE`
UNITE ? Ct N' T` CL. i'I- i '
Z,A1=11 r, AI0
A300 h'tl
A100-1-Ull A 1 Uu-Hill
A300-11LP Al b00 -HIP
G,
DEEP TEST PIT DATA
TP #95 (10-27-88)
0-6" DARK BROWN TOPSOIL
6-75" ORANGE BROWN LOAM WITH SOMI; SALT AND GRAVEL
75-87" TAN MODERATELY COMPACT, COBBLY FINE SAND & GRAVE
NO LEDGE, GROUNDWATER @ 46", MOTTLING AT 26"
TP #96 (10-27-88)
0-5" DARK BROWN TOPSOIL
5-28" ORANGE BROWN SANDY LOAM WITH GRAVEL
28-85" TAN MODERATELY COMPACTCOBBLY FINE SANDY
LOAM AND GRAVEL
MOTTLING AT 22", NO LEDGE, GROUNDWATER AT 84"
TP #125 (1-8-91)
0-12" TOPSOIL
12-42" LIGHT BROWN FINE SANDY LOAM
42-90" GREY -BROWN MEDIUM -FINE SILTY SAND, TRACE OF GRAVE
NO LEDGE, GROUNDWATER AT 36", MOTTLINrTG AT 30"
TP #126 (1-8-91)
0-10" TOPSOIL
10-33" LIGHT BROWN FINE SANDY LOAM
33-90" GREY -DROWN MEDIUM -FINE SILTY SAND, TRACE OFGRAVEL
NO LEDGE, GROUNDWATER AT 33", MO's TLING AT 26"
PERCOLATION TEST DATA
P- 10 A 6.0 MINifNeff, 24" DF_FffI(06-2( -91)
P- 10B 12.0 MIN/INCH, 24" DEPTH (06-20-91)
LOCATING D1M. F S10, S
FDN C.C. 1Z.I, I: I
FDN CORNER,
t)" 13OX0
WI_l"L L LOC'
x1S7)KiG
IN
1p7 9 5
GENERAL NOTI•: 4 CO..NTINUED
9. PRIOR TO 1-1 IE . JT RT OF CONSTRUCTION TEST HOLES'"W ", "X", "Y> & "Z" ARE TO BEDUGANDW1"1"1,'Sf:D BY THE UNCAS HEALTH DISTRICT.'
10. AFTER FILL. IS Pi.ACF:D AND COMPACTED, IT MUST BE PERC TESTED PRIOR TOINSTALLATIONofTLIESYSTEMBYTHEUNCASHEALTHDISTRICT.
1 BMX FROM F1,; I 0F_ WAI L
Q,
73' 7
1 8' Ire'
144' t;=
77'
GENERAL NOTES
I • BOUNDARY INFORMATION, INLAND WETLANDPITDATAANDLOCATIONS, 2' TOPOGRA.pHBOUNDARIES, TEST
TAKEN FROM A PLAN ENTITLED "LOCHDALE
END BENCHMARK
BERNARD BARNETT & HAROLD D. BATT FORS STATES PROPERTY OFJEFFERYMANORDRIVEMONTVILLE, CONN, " YTH ROAD ANDLTOTALTECHNOLOGY. THE B REV C JULY 9, 1992. BOUNDARY IS CERTIFIED CLASS A-2.
2. "SELECT FILL MATERIAL,,
WITHIN AND AND "BACKFILL MATERIAL", PLACEDADJACENTTOPROPOSEDLEACHINGAREASSCOMPRISEDOFCLEANSANDANDGRAVELFHALL BEMATERIALSANDDELETERIOUSSUBSTANCESEEFROMORGANIC
SHALL MEET THE FOLLOWING REQUIREMENTS FILL MATERIAL
APPROVED BY A PROFESSIONAL Q R-F=MENTS UNLESS OTHERWISE
LEACHING AREA: ENGINEER FOR USE WITHIN TIIE1 • THE FILL SHALL NOT CONTAIN ANYTHREE (3) NICHES. MATERIAL LARGER T
2• UP TO 45% OF THE DRY WEIGHT OF THE RESAMPLEMAYBERETAINEDONTHE #4 SIEVE
REPRESENTATIVE
GRAVEL PORTION OF THE SAMPLE. THIS IS TIDE
3. THE MATERIAL THAT PASSES THE 44 SIEVEREWEIGHEDANDTHESIEVEANALYSISSTARTL4• THE RE ED. G SAMPLE SHALL MEET THE FOLLOWINGGRADUATIONCRITERIA: G
SIEVE SIZE PERCENT PASSING4100°/° 10 0-100% L #40 0-50% 100 0-20%
NOTE: PERCENT PASSING THE
00 0-5%
40 SIEVE CAN BE INCREASED TO -NQGREATERTHAN75% IF THE PERCENT PASSING THE 100 SIEVE DOESNOTEXCEED10% AND THE #200 SIEVE DOES NOT EXCEED 5%.
THE RESPONSIBILITY FOR THE PREPARATION OF A LEACHING AREACUTILIZING "SELECT MATERIAL" IS THAT OF THE LITHEINSTALLERSHALLTAKETHENECESSARYSTEPS INSTALLER.
UNDERLYING NATURALLY OCCURRING S PS TO PROTECT TOILSFROMOVERCOMPACTIONANDSILTATION
ONCEM
EXPOSED.
3. AT THE TIME OF THIS DESIGN TI [ERE WERE NO EXISTING WELLSWITHIN75' OF THE PROPOSED SEPTIC SYSTEM AND THEEXISTINGSEPTICSYSTEMSWITHIN75' OF THE PROPOSED WERE NO
LOCATION. WELL
4. FOUNDATION DRAINAGE SHALL BE LOCATED NO CLOSE THAN 25FROMTHESEPTICSYSTEM. A RODENT PROOF COVER SHPROVIDEDONTHEFOUNDATIONOUTLETDRAINAT "
ALL BE
DA'LIGI-IT."
5. THE FOUNDATION AND SEPTIC SYSTEM SI -TALL BE STAKED OUT ANDGRADESESTABLISHEDBYALICENSEDLANDSURVEYOR
6. IF UTILIZATION OF THE RESERVE AIZEA IS EVERREQLTSEWAGEEFFLUENTPUMPEILLBEREQUIRED. IRFFD' A
7 0W'''I RlAPPLr TT1 ,
OAKDALE, CONN
860) 848-8861
3. ENGINEER: GARY J. `VINALSKI
9 HERI'T'AGE DRIVE
STONI NTGTON, CONN. 06378860) 535-2283
SANITARY DESIGN CRITER-IA
A. PROPOSED 3 BEDROOM HOME WITH BO100GALLONSINSIZE. DESIGNS*
SyJS
ROOM. NO TUBS OVLiHOMEEQUIVALENT. STEM FOR 4 BEDROOM
B. 1250 GALLON TWO COMPARTMENTCODEANDPROVIDED. SEPTIC T` N'K REQUIRED BY
C. DESIGN PERCOLATION RATE: 10.1 TO 20.0 M[N/INCH
D. NMMUM LEACHING SYSTEM SPREADH.F - 28 GRADIENT BETWEEN 8.1 &/oo
FF = 2.0 RESTRICTION BETWEEN 22.
10
FOUR. BEDROWv, HOME
26"
PF = 1.5 I'RECRATE .BETWEEN 10.1 20.0 MIN/INCH
MLSS=HFxFFxPF=28 x2.Ox 1.5 =84'
E. EFFECTIVE LEACHING AREA REQUIRED PER CODE; 900 SFF. 12" HIGH SIDE x SIDE INFILTRATORS SELECTEDSYSTEMDESIGN FOR LEACHING
EFFECTIVE LEACHING AREA PROVIDED PER LF PER CODE: 5.9 SFMINIMUMLENGTHOFSIDExSIDEINFILTRATORSREQUIRED:
900 SF/5.9 SF/LF = 152.5 FG. EFFECTIVE LEACHING AREA PR2ROWS- 87.5' LG x 12" HIGH
IDED
IDE x SIDE INFILTRATORS2x87.5 x 5.9 SF/LF = 1032.5 SF
H. 100% RESERVE AREA REQUIRED AND PRO VIDED
REVISION A- PLAN REVISED TO INCORPORATE COMMENTS IN UNCAS HEALTLETTERDATEDAPRIL5, 2002 H DISTRICT
PROPOSED ENGINEERED SEPTIC SYSTEM DESIGNLOT10
LOCHDALE DRIVE
ROCHDALE ESTATES
MONTVILLE, CONN.
FEBRUARY 2002