HomeMy WebLinkAboutPlan2w i k IP REC. 0 .4-.4 83.93 DEEP TEST PITS WERE WITNESSED BY ROBERT J. SCHUCH P.E. AND DAVE COUGHLIN OF UNCAS HEALTH DISTRICT ON 2-18-03, PERCOLATION TESTS P-1 AND P-2 WERE PERFORMED BY ROBERT J. SCHUCH P.E. ON 84.43 3-23-03. EXISTING WELL TO REMAIN PERCOLATION TESTS P-lA AND P -IB WERE PERFORMED BY ROBERT J. SCHUCH RE 01 SN 3-29-03. TEST PIT I I 0"- 14" DARK BROWN TOPSOIL • 0'�o 14'�- 40* LIGHT BROWN FINE SANDY LOAM 84.48 40'�- 92" GREY SAND AND GRAVEL GROUNDWATER 0 46" NO MOTTLING, NO LEDGE . - _ 0 TEST PIT #2 rjo/v 0"�- 12o DARK BROWN TOPSOIL CONC. 12'�- 24" LIGHT BROWN FINE SANDY LOAM MON, 24!- 65 n GREY SAND AND GRAVEL GROUNDWATER 0 397, MOTTLING0 24"p NO LEDGE NIF REC 8449 TEST � PIT #3 JAMES WARREN &2 4 -,. 0"- 12'° DARK BROWN TOPSOIL MARlAN H HUNT TRUST 12- 32* LIGHT BROWN FINE SANDY LOAM '! 32 - 96" GREY SAND AND GRAVEL VOLUME 247 PAGE 595 IW 87.66± 84.22 GROUNDWATER 9, J2" NO MOTTUNG, NO LEDGE VOLUME .9-05 PAGE '789 A, 24' OF 4'x 8x 18" HIGH CONCRETE LEACHING GALLERIES84,05 P- 1 PERCOLA 77ON RATIF 0 23" DEPTH 16 0 MINUTESIINCH BOTTOM OF GALLERIES X. 10'-4" PVC \ S=o. 10± �^Tpjl ELEV 86.70 P-2 PERCOLATION RATE 0 23" DEPTH 20.0 MINUTES P-lA PERCOLATION RATE 0 23' DEPTH = 20.0 MINUTES/INCH 1,000 GALLON X EXISTING HOUSE SEP77C TANK P-18 PERCOLATION RATE 0 23' DEPTH = 20.0 MINUTESIINCH INV 88.95 IN T 0 OAK TREE TE - 'A 7 -1 FF 96.0 INV` 88.70 OUT 2 /P REC. 4N cl (D/ST.) (REMOVE) SEDIMENT EXISTING 2 BEDROOM SEASONAL RESIDENCE DESIGN PERCOLATION RA TE = 10.1-20 MINUTES/INCH FENCE LEACHING AREA REQUIRED 500 SF EFFECTIVE P-18 -C WIDE, 18 /0 DESIGN. 1,000 --GALLON SEPTIC TANK AND 1 ROW OF 24' OF 8' LONG, 4 Ao Qton HIGH CONCRETE LEACHING GALLERIES WITH 12" OF 1" STONE SURROUNDING ALL SIDES. LEACHING AREA PROVIDED: 26" x 6.2 SF/LF = 161.2 SF EFFECTIVE `P 2# P-� 1 RESERVE AREA NOT REQUIRED FOR REPAIR BENCH MARK SPIKE IN ("'L&P 86 f �e SYS�rEM ELEVATION 9-9,77 EXISTING 2 BEDROOM I T'A Um -Ll-,A-Cj (ASSUMED DATUM) SEASONAL COTTAGE CAI FF 95.6± SPREA_ P-2 -6 APP ROXIMATE LOCATION SAN INV MLSS NOT REQUIRED f " REPAIR OF EXISTING SEPTIC 89.27 'QVICTVA-4 f0PCqr_)nnl I Tf) I -A P- IA EXISTING GRAVEL ROADWAY NIF RA YMOND D. & ELIZABETH L. CHESTER VOLUME 149 PAGE �918 35 LENA'S HOAD EXISTING WELL TO REMAIN 7 WAIVER REQUESTED (SEE NOTE #11) 30" OAK N;IF RAYMOND & ELIZABETH L. CHESTER VOLUME 270 PAGE 69 35A LENA'S ROAD ('Tjvc 1 RADIUS EXCAVATE 6 "x 6" TRENCH FILTER FENCE COMPACTED BACKFILL FLOW EXISTING GRADE UNDISTURBED GROUND F CTA I I 11A i If 9 NOT TO SCALE GRAPHIC SCALP f 20 ,rWwi A%w "684141 W' 4'x 8'x 18' HIGH CONCRETE LEACHING GALLERIES 1" STONE P- IA G END P-1 TOTAL DEPTH = 23 PRESOAK AT 10:05 PRESOAK AT 11:00 TIME rcb UTI 11TY POLE READING REC. RECOVERED 3-314" 12.00 7" 2:47 SNET SOUTHERN NEW ENGLAND TELEPHONE 8-318" PVMT. PAVEMENT 6-314" 12:20 9-718" Typ. TYPICAL f MORE OR LESS ilm 3:17 FT FIF. 12* W1 WITH 9-114' 12:50 12-718 3:37 9-718m EXISTING CONTOUR 13-112- Pvc POLYMNYL CHLORIDE 10-318" 1:10 4 S.F. SQUARE FEET PROPOSED CONTOUR 14 -J14 - Le ijo c FF FINISH FLOOR BSMT BASEMENT PERCOLATION TEST HOLE 0 TES T PIT LAW SURVEr7NG wHWORrAL LA14D RECORD RESEARCH SAN, SANITARY COMMERCW & REWEPOW DEVELOPMENT STCINE WALL INV. INVERT P.O. BOX 110 a RIVER ROAD ROUTE 12 ELEV. ELEVATION q 3V"'_0iNG SETBACK LINE LISBON, CONNECTICUT 06351 TELEPHONE 860) 376-2" FAX (8S 376-5899 88.2 PRC)POSED SPOT ELEVATION FILTER FENCE COMPACTED BACKFILL FLOW EXISTING GRADE UNDISTURBED GROUND F CTA I I 11A i If 9 NOT TO SCALE GRAPHIC SCALP f 20 ,rWwi A%w "684141 W' 4'x 8'x 18' HIGH CONCRETE LEACHING GALLERIES 1" STONE P- IA TOTAL DEPTH = 23" P-1 TOTAL DEPTH = 23 PRESOAK AT 10:05 PRESOAK AT 11:00 TIME READING TIME READING 2:37 3-314" 12.00 7" 2:47 5-112' 12:10 8-318" 2:57 6-314" 12:20 9-718" 3:07 7-314 rp 12:30 ilm 3:17 8-112- 12:40 12* 3:27 9-114' 12:50 12-718 3:37 9-718m 1:00 13-112- 3:47 10-318" 1:10 14-114" 1:20 14 -J14 - P -1 B TOTAL DEPTH - 23" PRESOAK AT 10:15 TIME READING 2:3400 4" 2:44:30 5-114" 2:54:30 6-118- 3:0400 7" 3:14:30 7-314 3:24:30 8-318" 3:34:30 9* 3:44:30 9-112' P-2 TOTAL DEPTH = 23" PRESOAK AT 11:18 TIME READING 12:23 6-114" 12:31 10-112 GALLERI** 12:36 12' 12:41 13" 12:46 13-518" 12.51 14-114" 12:57 14-314" 1:02 15-114" 1:07 -07 15-1/2" 1:12 15-314" FINISHED GRADE LOAM AND SEED, GRADE TO PREVENT PONDING FILTER FABRIC APPROVED BACKFILL AS REQUIRED 18" MIN. TO MOTTLING/OR GROUNDWATER 48" MIN. TO LEDGE/ROCK 1-7 [7) 1 7 A 4 tN"")'T'eEs I, THIS i SURVEY AND MAP HAS BEEN PREPARED IN ACCORDANCE WITH SECTIONS 20-3008-1 THROUGH 20-3008-20 OF THE ;REGULATIONS OF CONNECTICUT STATE AGENCIES - ISTANDARDS FOR SURVEYS AND MAPS IN THE STATE OF CONNECTICUT" AS ENDORSED BY THE CONNECTICUT ASSOCIATION OF LAND SURVEYORS, INC. IT IS A TOPOGRAPHIC SURVEY AND CONFORMS TO HORIZONTAL CLASS 8 AND TOPOGRAPHIC CLASS T-2 ACCURACY STANDARDS. IT IS INTENDED TO BE D USED FOR SITE DEVELOPMENT 1 2. THE HORIZONTAL CLASS 8 ACCURACY STANDARDS APPLY TO THE HORIZONTAL MEASUREMENT OF MONUMENTATION IDENTIFIED AS RECOVERED. NO SURVEYORS PROPERTY18OUNDARY OPINION IS EXPRESSED OR IMPLIED BY THIS PLAN. THIS MAP WAS PREPARED FROM RECORD RESEARCH, OTHER MAPS, LIMITED FIELD MEASUREMENTS AND OTHER SOURCES. IT IS NOT'TO TO BE CONSTRUED AS A PROPERTY18OUNDARY OR LIMITED PROPERTY18OUNDARY SURVEY AND IS SUBJECT TO SUCH FAC AS SAID SURVEYS MAY DISCLOSE. 3. CON URS AND VERTICAL DATUM AS SHOWN ARE DERIVED FROM ACTUAL FIELD SURVEY AND ARE BASED ON ASSUMED DA T 4. REF 4 CON MAP: A. HE FORMER EDWARD E REYNOLDS TRACT, SCALE 1"= 80'." )AI :VO�rES GENEI� 1. THIS PROSECT INVOLVES THE INSTALLATION OF SEPTIC REPAIR SYSI. FOR AN EXISTING 2 BEDROOM SUMMER COTTAGE IN ACCORDAOCE WITH THE CONNECTICUT PUBLIC HEALTH CODE. 2. THIS SEPREPAIR SYSTEM INSTALLATION SHALL CONFORM TO THE CURRENT EDITIONIREVISION OF THE "CONNECTICUT PUBLIC HEALTH E" BY THE STATE OF CONNECTICUT DEPARTMENT OF PUBLIC HEALTH. ALL MATERIALS (PIPING, SEPTIC TANK, STONE, FILL, ETC. 'tD USED FOR THIS SEPTIC SYSTEM SHALL CONFORM TO THE CURRENT EDITION/REVISION OF THE -TECHNICAL STANDARDS USED FOR THE ESIGN AND CONSTRUC77ON OF SUBSURFACE SEWAGE DISPOSAL SYSTEMS" REVISED JANUARY 1, 2000. J. ALL PRO- SED SEWER PIPE FOR THIS SEPTIC SYSTEM SHALL BE 4" PVC ASTM 0034, SDR 35 WITH RUBBER COMPRESSION GASKET BELL AND SPIGOT OR APPROVED EQUAL. 4. THERE NO WELLS WITHIN 75' OF THE PROPOSED SEPTIC REPAIR SYSTEM EXCEPT FOR THE NORTHERN ABUTTER'S WELL AND THE OWN 'S WELLS. SEE NOTE 11 FOR WAIVERS REQUESTED FROM THE CONNECTICUT PUBLIC HEALTH CODE 5. THERE S BE NO STUMPS OR BOULDERS BURIED WITHIN 50' DOWN GRADIENT OF THE SEPTIC SYSTEM. SHOULD ANY SIGNIFF71CA VARIATIONS FROM THE TEST HOLE DATA BE ENCOUNTERED DURING EXCAVATIONS (LEDGE, GROUNDWATER, MOTTLING, SOIL TYPE, - THE UNCAS HEALTH DISTRICT SHALL BE NOTIFIED PRIOR TO INSTALLATION OF THE SEPTIC SYSTEM. 6. ALL EXIS-i UTILITIES ARE APPROXIMATE ONLY. THE CONTRACTOR SHALL VERIFY ALL UTILITY LOCATIONS AND ELEVATIONS PRIOR TO ANY C STRUCTION. CONTRACTOR SHALL CONTACT "CALL -BEFORE- YOU -DIG'* AT 1-800-922-4455 AT LEAST 48 HOURS PRIOR TO ANY r"- VAPON. 7. THE PRO, ED FILL FOR THIS SEPTIC SYSTEM REPAIR SHALL MEET THE FOLLOWING SPECIFICATIONS: 100% OF LL SHALL PASS THROUGH A 3" SIEVE. MAXIMUM OF GRAVEL (BETWEEN 14 & 3- SIEVE) = 45%. GRADAT70P OF F7LL WITHOUT THE GRAVEL SHALL BE. SIEVE SIZE X PASSING 4 100% 10 70 - 100% # 40 10 - 50% # 100 0 - 20% 1 200 0 - 5% PERCOLA, N RATE AFTER PLACEMENT AND COMPACTION SHALL BE FASTER THAN OR EQUAL TO 10.0 MINUTES/INCH. A SIEVE PSIS MAY BE REQUIRED PRIOR TO FILL PLACEMENT TO VERIFY THAT IT MEETS THESE SPECIFICATIONS. THE FILL SHALL BE APPR,() 0 BY AN UNCAS HEALTH DISTRICT SANITARIAN PRIOR TO ITS PLACEMENT ON SITE. 8. NO DEWA T FROM THE APPROVED SANITARY REPAIR DESIGN PLAN SHALL BE ALLOWED WITHOUT PRIOR APPROVAL FROM AN UNCAS H TH DISTRICT SANITARIAN. 9. SITE PREF RA77ON PROCEDURE FOR THE INSTALLATION OF THE PROPOSED SEPTIC REPAIR SYSTEM: A, STRW° AL !_IL, VEGETATJOIV_ FILL_ ANJ2-ORGANIC MATERIAL 4N THE AREA -OF 0WR 5' SURROUNDING THE PROPOS­ LEACfP% C,'A'_'LFT"?IEr3. -US&C A hEAVY RAKE OR EQUAL, THOROUGHLY SCARIFY AND ROUGHEN Up THE EXPOSED SUBSOIL. VEHICULAR TRAFFIC, BACKHOE TRUCKS, ETC. FROM SA400THINGICOMPACTING THIS EXPOSED SUBSOIL. C. PtAC .. lz FALL AMTERIAL MEETING SPECIFICATIONS INDICATED ABOVE (NOTE 16) IN LIFTS OF NOT GREA'W THAN 12'w IN THE AREA OF THE PROPOSED LE4CHING GALLERIES UP TO AT LEAST THE ELEVATION OF THE Top OF LEAC-11 I GALLERIES. D. PERF, AT LEAST 1 PERCOLATION TEST ON PLACED FILL. FILL MUST HAVE A PERCOLATION RATE EQUAL TO OR FASTER THAM T AS INDICATED IN NOTE 16.0. IF PERCOLATION RATE IS SLOWER THAN THAT RATE, ALL FILL SHALL BE REMOVED AND REPLY D WITH ACCEPTABLE FILL MEETING PROPER SPECIFICATIONS. INSTA" SEPTIC SYSTEM PER PLAN. F COVETEM WITH A MINIMUM OF AT LEAST 8' OF LOAM IN LAWN AREAS. GRADE AREAS TO PREVENT PONDING AND SEED LAK IAS WITH GRASS TO STABILIZE THE FINISHED GRADE 10" FROM ANY PART OF THE PROPOSED LEACHING GALLERIES SHALL BE A T THE SAME ELEVATION AS THE TOP OF THE RESPECTIVE LEACHING GALLERY G. CLEA'4 MANHOLE'S AT THE INLET BAFFLE AND AT THE OUTLET FILTER OF THE SEPTIC TAW OR ASSOCIATED RISERS AT THE" S1-1 OCATIONS IF REQUIRED, SHALL BE LOCATED AT A DEPTH NOT GREATER THAN 12" BELOW FINAL GRADE, 10. THE EXT:- SEPTIC SYSTEM LOCATION (SIZE AND TYPE UNKNOWN, BELIEVED TO BE A CESSPOOL) IS APPROXIMATE AND IS SHOWN ON THE OWNER'S RECORDS THIS SYSTEM WILL BE ABANDONED IN PLACE. CESSPOOL SHALL BE PUMPED OUT AND FILL WITH CLEAN GRAVEL. 11. THE FOLNG WAIVERS ARE REQUESTED FROM THE CONNECTICUT PUBLIC HEALTH CODE - A. RED V:': THE DISTANCE FROM THE SEPTIC REPAIR SYSTEM TO A WELL FROM 75' REQUIRED TO 50' FROM NEIGHBOR'S WELL AND 67.5' OWNER'S WELL. 8. RE010ij THE DISTANCE FROM THE SEPTIC REPAIR SYSTEM TO A PROPERTY LINE FROM 10' REQUIRED TO 7. -ANL?­ Xv C S y PREPAR,F0 FOR A L 'TO rvy LED E BEUEF THIS MAP IS SUBSTANTIALLY 3 7 L EN'S ROAD COR ONTVILLE, CONNECTICUT PSI 7W16 7�e SCALE: 1 =10OCTOBER 2003 JOB 1. 0. NO. 03-824 J NN 0 FAULISE JR. LICENSE NO. DATE REVISION P4 PER CONDITIONAL APPROVAL 11-11-03