TEST HOLE DATA
PER UNCAS HEALTH DISTRICT
AUGUST 4, 2004
TH#9 - 0"-4" TOPSOIL
- 4"-32" BROWN SANDY LOAM
- 32"-76" GREY MED. COMP. SANDY TILL
NO WATER, MOTTLING, NO LEDGE
TH#I 0 - 0"-8" TOPSOIL
- 8"-26" BROWN SANDY LOAM
- 26"-83" GREY MED, COMP. SANDY TILL
NO WATER, MOTTLING, LEDGE@83?f
TH#II - 0"-12" TOPSOIL
- 12"-33" BROWN SANDY LOAM
- 33'1-72" GREY MED. COMP. SANDY TILL
NO WATER, MOTTLING, LEDGE@72VT
TH#12 - 0"-9" TOPSOIL
- 9"-34" BROWN SANDY LOAM
- 34"-68" GREY MED. COMP. SANDY TILL
NOATATER, MOTTLING, NO LEDGE
I
0
30LF-4"PVC!
_CHMARK
BEN
4�'
0� C5 TOP OF IPIN TH#9,"
A�
6LF-4"PVC
A,
ASTM D1785
ELEV,,"407.00
SDR35
A�
3
0 1 W'Zt A T T R, 7%4 A TKITA'��T A rnWTTTXTT TnT TQ
CNI
MLSS DATA
11
4 BEDROOM HOUSE REQUIRES 660 S.F.
OF EFFECTIVE LEACHING AREA
USE (3) - 75' LONG 48", WIDE STONE TRENCHES
75 x 3 x 3 = 675 S.F.)
USE 1,250 GAL 2 COMPARTMENT SEPTIC TANK
W/ OUTLET FILTER DEVICE
4
CL&P
I'll
N/F
JOSH -UA A. & ROBIM M. ZUCKER�AAV
LEGEND:
F,F,
FIRST FLOOR
EL,
ELEVATION
S.F.
SQUARE, FEET
TYP.
TYPICAL
IPIN
IRON PIN
MON
MONUMENT
DH
DRILL HOLE
x122.5
EXISTING SPOT ELEVATION
x127.2
PROPOSED SPOT ELEVATION
120
EXISTING CONTOURS
120 m
PROPOSED CONTOURS
BUILDING SETBACK LINE
TEST HOLE
COWACTED
BACKFILL--"
CONNECTICUT APPROVED-----_
FILTER FABRIC
4" PERFORATED
PIPE
STONE AGGREGATE
(SEE NOTES)
ANGLE 10" UP SLOPE
FOR STABILITY AND
SELF CLEANING
ami
SILT FENCE
NOT TO SCALE
TOPSOIL
SUITABLE FILL
m
TRENCH
CROSS SECTION
NOT TO SCALE
a 1 3 1 r-IVL 11N V z m 13
C - 113.75 MIN. OUTLET AT HOUSE
20 - 111.50 INLET @ TANK
(3) - 111.25 OUTLET @ TANK
(4) - 1110.50 INLET & TRENCH INVERT (BOTTOM TRENCH EL, -110.00) EXIST. GRADE- 112.0 1 V
Hl -LEVEL OVER -FLOW - TOP OF ELBOW EL.- I 10.80 IPIN
- R8.50 INLET& TRENCH INVERT (BOTTOM TRENCH EL. -108.00) EXIST. GRADE- 110.0 REC.
H[ -LEVEL OVERFLOW - TOP OF ELBOW EL. -108.80
- 107.00 INLET & TRENCH INVERT (BOTTOM TRENCH EL. -106.5) EXIST. GRADE - 108.5
4" PVC ELBOW
(CUT FOR 4" OVERFLOW)
2X2 5/8 16 GA. WIRE MESH
1 1/2"
1 17n -1
et
00
eq 2"
I
l0f-6"
KNOCKOUT INLET AND
OUTLET OPENINGS
CAST
CONCRETE COVERS
/- 4 x 4 12.6/12.6 GA. WIRE MESH
17 1/2" f- 6 x 6 6/6 GA. WIRE MESH
LIQUID LEVEL--- lr�
CONTINUOUS HOT
" ASP SEAL
4" SCHED. 440
TNTPTRAPP
CROSS SECTION
1250/1500 GALLON
2 COMPARTMENT
SEPTIC TANK
NOT TO SCALE
OUTLET
7
OUTLET
IFILTER
DEVICE
7_ 0
-
TO N Al -BELIEF, THIS MAP IS SUBSTANTIALLY CORRECT
ASN U -AP IS NOT VALID WITHOUT A LIVE SIGNATURE
OF T URVEYOR HEREON.
FID EX
A Nt D
6 A
RIC14ARD iItWVR�PS L.S. 470019 DATE
PROJECT NO.
05-086
DRAWN BY:
R.A.D.
DATE:
9/20/05
SCALE:
lft=W
EROSION AND SEDIMENT CONTROL PLAN:
1. CLEARING, GRUBBING, AND GRADING OF THE PROPOSED SITE
TO BE LIMITED TO AREAS ADJACENT TO THE PROPOSED HOUSE
AND SEPTIC SYSTEM.
2, DISTURBED AREAS TO BE LOAMED, SEEDED, AND MULCHED.
3. ALL TOPSOIL TO BE STOCKPILED ON SITE AND PROTECTED
WITH HAYBALES OR SILT FENCE.
4. ALL CUT AND FILL SLOPES ARE NOT TO EXCEED 3:1 SLOPES.
5, PRIOR TO SITE DISTURBANCE, THE REPRESENTATIVE OF THE
TOWN OF MONTVILLE SHALL BE NOTIFIED WHEN SEDIMENT
CONTROL MEASURES ARE IN PLACE SO THATTHE INSPECTION
CAN OCCUR.
6. THE CONTRACTOR WILL BE RESPONSIBLE FOR THE INSTALLATION
AND MAINTENANCE OF ALL REQUIRED SEDIMENT CONTROL
MEASURES THROUGHOUT CONSTRUCTION,
7, DUST CONTROL WILL BE ACCOMPLISHED BY SPRAYING WITH
WATER, AND IF NECESSARY THE APPLICATION OF CALCIUM CHLORIDE.
TEMPORARY VEGETATIVE COVER:
MULCHES APPLICATION RATE
PER 1000 S.F.
STRAWMAY 70-90 lbs.
WOOD CHIPS 185-275 lbs.
PLANTING SCHEDULE:
SEEDING DATES:
APRIL I ------- JUNE 15
AUGUST I ------ SEPTEMBER 15
SEED MIXTURE:
45% RED FESCUE
45% KENTUCKY BLUE GRASS
10% PERENNIAL RYE
DESIGN NOTES:
I ALL CONSTRUCTION TO CONFORM TO STANDARDS OF THE CONNECTICUT
PUBLIC HEALTH CODE AND TO THE SATISFACTION OF THE TOWN SANATARIAN,
2. THIS SYSTEM HAS NOT BEEN DESIGNED FOR THE USE OF LARGE,
CAPACITY (+100 GALLONS), DISCHARGE TYPE BATHTUBS, RESIDENTIAL
GARBAGE DISPOSALS ARE NOT ANTICIPATED FOR THIS DESIGN. IN THE
EVENT THAT SUCH AN INSTALLATION IS CONTEWLATED FOR THE
PROPOSED HOUSE, A LARGER SEPTIC TANK AND INCREASED LEACHING
FIELD CAPACITY WILL BE REQUIRED.
LEACHING SYSTEM CONSTRUCTION NOTES:
l: TOPSOIL TO BE STRIPPED OFF PRIOR TO FILLING. FILL MATERIAL BETWEEN AND BEYOND
TRENCHES TO BE PERVIOUS, GOOD QUALITY AND CLEAN MEDIUMS (SELECT FILL) PLACED
AND COMPACTED IN 6" LIFTS, SELECT FILL SHALL MEET THE FOLLOWING MINIMUM REQUIREMENTS:
A. THE FILL SHALL NOT CONTAIN ANY MATERIAL LARGER THAN 3 INCHES.
B. THE FILL SHALL NOT CONTAIN MORE THAN 45 PERCENT GRAVEL (GRAVEL IS BETWEEN NO. 4 & 3" SIEVES)
NO MORE THAN 45 PERCENT OF THE MATERIAL CAN BE RETAINED ON THE NO, 4 SIEVE
C. THE FILL LESS THE GRAVEL SHALL MEET THE FOLLOATNG GRADATION CRITERIA:
SIEVE SIZE: 44 #10 #40 #100 #200
% PASSING: 100 70-100 **10-50 0-20 0-5 WIFT SIEVE
% PASSING: 100 70-100 10-75 0-5 0-2.5 DRQ' SIEVE
PERCENT PASSING THE #40 SIEVE CAN BE INCREASED TO NO GREATER THAN 75% IF THE PERCENT
PASSING THE #100 SIEVE DOES NOT EXCEED 10% AND THE #200 SIEVE DOES NOT EXCEED 5%.
2. DOCUMENTATION OF TEST RESULTS ARE TO BE PROVIDED TO THE HEALTH DISTRICT.
3. FILL MATERIAL TO BE PLACED PRIOR TO TRENCH EXCAVATION. NO TRAFFIC OTHER THAN
TRACK -DRIVEN EQUIPMENT IS TO CROSS, DUMP, UNLOAD OR OTHERWISE COMPACT THE FILL AREA
AFTER TOPSOIL REMOVAL FILL MATERIAL TO BE DUMPED AT THE EDGE OF THE STRIPPED AREA AND
SPREAD AND COMPACTED WITH TRACK -DRIVEN VEHICLES. STOCKPILING IS TO TAKE PLACE UPGRADIENT OF
THE LEACHING AREA. THE AREA DOWN GRADIENT OF THE LEACHING AREA ITS NOT TO BE DISTURBED.
SEPTIC SYSTEM CONSTRUCTION NOTES:
I CONSTRUCTION SEQUENCE:
A. STRIP & STOCKPILE TOPSOIL FROM LEACHING TRENCH A.
B. PLACE SELECT FILL TO 6" BELOW EXISTING GRADE.
C. CONSTRUCT LEACHING TRENCHES TO DESIGN LINE & GRADE,
D, LOAM, FINE GRADE TO FINISHED GRADE AND SEED, PROTECT DISTURBED AREAS
WITH EROSION CONTROLS UNTIL FIRST MOWING,
2. THE PIPE BETWEEN THE HOUSE AND SEPTIC TANK SHALL BE 4 IN. EXTRA HEAVY CAST IRON,
DUCTILE IRON OR EXTRA STRENGTH PVC ASTM D1785 SCHD 40 OR APPROVED EQUAL.
I ALL DISTRIBUTION PIPE IS TO BE ASTM D3034 SDR 35 (4"PVC) OR APPROVED EQUAL UNLESS NOTED.
4. SEPTIC TANK SHALL BE SET LEVEL ON A MINDVIUM OF 6" OF PROCESSED GRAVEL OR BROKEN
STONE ON COMPACTED SUBGRADE.
5. THERE ARE NO APPARENT WELLS OR SEPTIC FIELDS WITHIN, 75' OF THE PROPOSED WELL AND
SEPTIC SYSTEM AS SHOWN ON THIS PLAN.
6. APPROVED STONE AGGREGATE FOR LEACHING TRENCHES SHALL BROKEN STONE, CRUSHED
STONE, OR SCREENED GRAVEL MEETING CT DOT FROM 814A SPECIFICATION FOR M.0 1.0 1 FOR NO. 4
STONE:
SIEVE SIZE PERCENT PASSING (BY WEIGHT)
2 -INCH 100
1 -1/2 -INCH 90-100
I - INCH 20-55
3/4 -INCH 0-10
3/8 -INCH 0-5
7. THE LOCATION AND ELEVATION OF THE PROPOSED SEPTIC SYSTEM SHALL BE STAKED IN THE
FIELD BY A LICENSED LAND SURVEYOR.
NOTES:
1. TOPOGRAPHIC INFORMATION ON THIS PLAN COMPLIES WITH T-2 MAPPING
STANDARDS.
2. PROPOSED HOUSE AND SEPTIC SYSTEM TO BE STAKED IN THE FIELD BY
A LAND SURVEYOR LICENSED IN THE STATE OF CONNECTICUT,
3. BASE FOR LEVELS: PER REFERENCE MAP.
4. PROPERTY IS LOCATED IN THE TOWN OF MONTVILLE ZONING DISTRICT R-80.
5. THERE ARE NO WELLS LOCATED WITHIN 75' OF THE PROPOSED SEPTIC SYSTEM
LOCATED ON ABUTTING PROPERTIES.
6. TOTAL AREA OF PROPERTY - (I.84 ACRES
T A BENCHMARK IS TO BE PLACED WITHIN 50' OF THE PROPOSED HOUSE &
SEPTIC SYSTEM ATT TIME OF CONSTRUCTION.
8. IF BLASTING IS NECESSARY A PRE -BLAST SURVEY SHALL BE REQUIRED
PRIOR TO THE START OF CONSTRUCTION,
REFERENCE MAP:
SUBDIVISION PLAN PREPARED FOR JAMES McCLOY, 376 RITE UG
ROAD, MONTVILLE, CONNECTICUT, SCALE: I "=40', DATED 12/14/05,
REVISED TO 6/1/05, PREPARED BY CME ASSOCIATES, INC.
SEPTIC SYSTEM DESIGN PLAN
PREPARED FOR
KITEMALTG ROAD
MONTVILLE, CONNECTICUT
LOT #26/005-004
ADVANCED SURVELS
LLC.
W
20 10 0 20 24 St. Regis Avenue Norwich CT. 06360
...... I ........ W Phone & Fax (860) 859-1280
GRAPHIC SCALE IN FEET S