Loading...
HomeMy WebLinkAboutSite Plan�L r� m m 0 0 N T r 0 LO co 0 0 CIO co A is -Y- rM}� r SCALE. 111 — 100' WF +•. � WF r { o ` *5&oe 1 \~ u,F Fp. = 422.5 WF WELL R4DIUS WF =.PROPOSED } `I\ 3 BEDROOM HOME PROPOSED j F�.-424.0 WELT. FOOTING } DRAIN 1 T ur- J PEI 1000 . GAL 050 I SEPTIC TANK \ 031-009 / TH9E 50 / -- / WETLANd '\ FIN,R 0556 \ 3 ROWS OF 60 Lr- LEACHING FLEACHINCA TRENCH UJF TH9G TH9H � '' Ll LF r- c TEST HOLES RECORDED ROBERT RUSSO ON APRIL 2<3,2003 tH 013 122" TOTAL DEPTH 0"-9" TOPSOIL DARK BROWN SANDY LOAM 9"-96" SUBSOIL YELLOW BROWN t BROWN BANDED SAND 96"-122" GRAY t GRAY BROWN BANDED SAND NO BEDROCK NO WATER NO MOTTLING TW 015F 111" TOTAL DEPTH 0"-5" TOPSOIL DARK BROWN SANDY LOAM 5"-61" SUBSOIL YELLOW BROWN i STRONG BROWN BANDS OF MEDIUM TO COARSE SAND 67-111" GRAY BROWN t GREY BANDS OF MEDIUM SAND NO BEDROCK NO WATER NO MOTTLING TH 013G 130" TOTAL DEPTH 0"-8" TOPSOIL DARK BROWN SANDY LOAM 8"-53" YELLOW BROWN 4 STRONG BROWN BANDS OF SAND t COARSE SAND 53"-130" bROWN t GRAY BROWN BANDED SAND NO BEDROCK NO WATER NO MOTTLING TW 013P 121" TOTAL DEPTH 0"-6" TOPSOIL DARK BROWN SANDY LOAM 6"-121" SUBSOIL YELLOW BROWN t GRAY BROWN BANDS OF MEDIUM SAND t COARSE SAND W/ PEBBLES NO BEDROCK NO WATER LNO MOTTLING CLA OT 9 - PERCOLATION TEST DATA: TOTAL DEPTH - 351 " PRESOAK AT 10:50-11:?3 PRESOAK 2 AT 11:20-11:37 12:05 - 24" 12:06 - 26" 12:0- - 26" 12:08 - 2'3" 12:09 - 30" 12:10 - 31" 12:11 - 32" 12:12 - 32.5" 12:13 - 33B" 12:14 - 34.5" PERCOLATION R4"E: 11" 1NAN SEPTIC SYSTEM DESIGN LOT9 PRIMARY SYSTEM: PERCOLATION RATE: 1 TO 10 MINJINCH 3 BEDROOM HOUSE EFFECTIVE LEACHING AREA REQUIRED = 495 SF USE A 12" DEEP x 48" WIDE TRENCH EFFECTIVE LEACHING AREA OF TRENCH = 3 SF/LF LENGTH OF TRENCH REQUIRED = (4955FX3SF/LF) = 165 LF DEPTH TO RESTRICTIVE LAYER = NONE MLSS NOT REQUIRED USE THREE ROWS OF 60' AT 9' O.C. LEACHING AREA PROVIDED - 540 SF RESERVE SYSTEM: USE SAME DESIGN AS PRIMARY SYSTEM 1➢ x 30' SETBACK, 30' SETBACK NON -WOVEN FILTER FABRIC 6" SOIL COVER OVER STONE 4" PVC PERFORATED PLASTIC FINISH / DISTRIBUTION PIPE (ASTM D 3033) GRADE ONE INCH CLEAN BROKEN 2" STONE OR SCREENED GRAVEL 12" INVERT 6 � 48" WIDTH _ 18" — MOTTL ING LINE *564 12 x 48" LEACHING TRENCH NOT TO SCALE I 43/411 INLET 18"D 1,4. COYER 5" i"iIN INLET = 8'"-18' 10" BAFFLE MIN _ m � �t 4'-5 3/4" LIQUID 4„ 3" WALLS LEVEL _ CpOSS SECTION VIEW 000 GALLON SEPTIC TANK NOT TO SCALE OUTLET OUTLET FILTER DEVICE SITE qo� LOCATION MAP TT 1!!C A Engineers Inc. IVIL - STRUCTURAL - SURVEYING V317 Main Street Norwich, Connecticut 60) 886-1966 Fax (860) 886-9165 No. Date Revision Project No. LOT 9 — 2 JAMES WAY CIA -3335 Proj. Engineer DEERRIDGESUBDIVISIONE.M.B. Date: MAY 2004 MONTVILLE, CONNECTICUT 20 m 2D AC' !' Sheet No. 8C"kXS 1,020,'e SEPTIC SYSTEM LAYOUT