Loading...
HomeMy WebLinkAboutBoundary PlanV y 0 Itt N O N V Cn PC z o to W Q c j V v U- V J W k � V QZ zo O ci j o �W � �W � � w ~ 4 Z Q m ` Y w . a cn i. k ROBE T JOHNSTON, P. E. 08961 toll, sa.4ta/'t %%fr a A. m f fq �f'101,0 11lEti91i�R�`ia�`ati JAMES W.OUTTON, L.S. AF70074 This document is an Instrument of professional service, and shall not be used, In whole or In port, for any project other then for which it was created without the express, written consent of DUTTON do JOHNSTON, LLC. Any unauthorized use, reuse, mod/flcation or conversion of this document shaft be of the user's sole risk without liability or legal exposure to DUTTON do JOHNSTON, LLC. O 2002 — DUTTON & JOHNST'W LLC. THIS PLAN HAS BEEN PREPARED AND APPROVED BY DUTTON & JOHNSTON, LLC FOR: 1APPR. BY I DATE: AL REVISIONS: 1212212005- SEPTIC, GRADING nK1-,?.1/9fnFi - i4n1I SF nnivF R DATE: 11/09/2005 SCALE: 1' - 20' SHEET 2 of 3 A -44-087-P1 04087 -PLOT PLAN.DWG TURN END SECTIONS OF SEDIMEN T BARRIER UP SLOPE TO PREVENT BYPASS OF WATER END SE•CTION� RL TER FABRIC• OAK STAKES 10' ON CEN7ER, TYPICAL THE MIDDLE SECTION SHALL BE INSTALLED LEVEL FOLLOWING THE GROUND CONTOUR UNE I SEC770N GRADE, TYP. /-F/L MER FABRIC EXCAVATE EXISTING SOIL AND FIRMLY EMBED BOTTOM OF F7L TER FABRIC --- FLOW i --EXISTING GRADE, TYP. STAKE 12" MIN. PO �0 G60, QVy Q�oAQVb cJa In a n Ii4 Q�(�A ,L]s�'D�a Q C Vthh �41 7 < c� a a4 , ha n n� a Z ?G UhYOA•J �c'"p� 4 '��fbCJV D° pc I aa� $1; n Q Qn ,(3 n • 4 qct tin A A 'A o 0 3� g r ,s6 CT D.O. T. 2" STONEad� a3 a'3 aClo c) bba Qggn b qq F7L7ER FABRIC EXISTING GRADES . c; PROVIDE RISERS IF 774E TOP OF FINAL /-THE SEP71C TANK IS DEEPER 714AN 12"1 -GRADE MIN. 17" DIA. MANHOLE INSPECTION OPENING a if (OPTIONAL)l k,v= WARKIN LU INLET INLET BAFFLE --- OUTLET C)U7LET FX IFR UEWaE � A 1/3 REQUIRED CAPACITY -1 C0NCRE7E SEP77C TANKS SHALL CONFORM TO SECTION V. "SEPTIC TANKS" OF THE "CONNECTICUT PUBLIC HEALTH CODE, REGULA 710NS AND 7ECHN/CAL STANDARDS FOR SUBSURFACE SEWAGE DISPOSAL SYSTEMS", REVISED THROUGH JANUARY 1, 2004. NOT TO SCALE GRADE LOAM AND SEED FILTER FABRIC, TYPAR / 3151 OR APPROVED EQUAL 1'0 DIA. CRUSHED STONE 4" PERFORATED A V C. PIPE HOLES DOWN ocy, -men WIT RW3141 N VLSAND FILL, IF REQUIRED BOTTOM OF TOPSOIL, TYPICAL 4'1'DE LEACHING ll4ENCH NOT TO SCALE OPTIONAL OUTLET LOCATION 90' PVC ELL I– _ –_--� 1 1 /IVLer I OUR ET— NOTE. INLET FLOW UNE ELEVATION AT 774E \_PERFORATED DISTRIBUTION BOX SHALL SIE SETA MINIMUM DISTRIBUTION PIPE OF 6" BELOW THE OUTLET ELEVATION OF THE SEPTIC TANK. NOT TO SCALE PROVIDE ..5' OF COVER OR INSULA W q AS REQUIRED M 0o00000 °0 0000 °o 0000 °o :o0 '00o 00 �c°0°00000 00000 OGo-%0000;0 DISTRIBUTION BOX SEE DETAIL SEPTIC SYSTEM NOTES: THE SEP77C SYSMY SHALL BE INSTALLED IN ACCORDANCE WITH THE STATE OF CONNECTICUT PUBLIC HEALTH CODE. SERIAL O/S7R/BU770N SHALL BE USED. TOPSOIL W1774IN 774E LEACHING AREA SHALL BE STRIPPED PRIOR TO PLACEMENT OF 774E SAND FILL, EXCAVATION EQUIPMENT IS NOT PERMITTED IN 774E LEACHING AREA UN71L THE SAND FILL HAS BEEN PLACED AND COMPACTED. THE SAND FILL SHALL BE COMPACTED TO 90X OF OP77MUM DENSITY AND SHALL BE PLACED IN LIFTS NOT EXCEEDING 12 INCHES /N DEP774. SAND FILL SHALL CONSIST OF A CLEAN UNIFORM BANK RUN SAND OR GRAVEL AND SHALL BE APPROVED BY 774E LOCAL HEALTH AUTHOR/TY PRIOR TO PLACEMENT. A LICENSED SEPTIC INSTALLER MUST OBTAIN A "PERMIT TO CONSTRUCT" FROM 714E HEAL 7H DEPARTMENT BEFORE BEGINNING THE SEPTIC SYSTEM. THE LEACHING AREA SHALL BE STAKED FOR CONSTRUCTION BY A LICENSED LAND SURVEYOR. 714E CONTRACTOR SHALL COORDINATE INSPECTIONS WITH THE HEALTH DEPARTMENT. PIPING FROM 774E FOUNDA77ON WALL TO THE SEPTIC TANK SHALL BE 4" MINIMUM /N DIAMETER AND COMPLY W774 TABLE NO. 2 OF THE HEALTH CODE. THE PIPE SHALL BE INSTALLED AT A MINIMUM P/TCH OF 1/4 IN117. PIPING FROM THE SEPTIC TANK TO THE DISTRIBUTION BOX, BETWEEN INE DISTRIBUTION BOXES AND PERF0RA7ED DISTRIBUTION PIPE SHALL BE 4" IN DIAMETER AND COMPLY WITH TABLE Na 5 OF THE HEALTH CODE. ALL CHANGES /N PIPE DIRECTION OR GRAD SHALL BE MADE W1 TH PROPER F1 mws. THE SEPTIC TANK INSPECTION OPENINGS SHALL BE PROVIDED Wl TH RISERS IF GREA TER THAN 12" BELOW GRADE. TOPSOIL AND 0774ER ORGANIC MATERIAL WHIN THE LEACHING AREA SHALL BE STRIPPED PRIOR TO PLACEMENT OF SELECT FILL MATERIAL 774E LEACHING AREA SHALL BE "ROPED OFF" OR 0774ERWISE PROTECTED FROM DIS7URBANCE UNTIL CONSTRUCTION ON THE LEACHING AREA IS STARTED. SELECT FILL IT /S THE RESPONSIBILITY OF 774E SEP71C INSTALLER TO PROVIDE SELECT FILL MATERIAL 1N CONFORMANCE Wl TH THE FOLLOWING. THE SEP77C INSTALLER SHALL PROVIDE A SIEVE ANALYSIS TO THE HEALTH DEPARTIWENT FOR APPROVAL /F REQUESTED. SELECT F7LL PLACED WITHIN AND ADJACENT TO LEACHING SYSTEM AREAS SHALL BE COMPRISED OF CLEAN SAND, OR SAND AND GRAVEL,, FREE FROM ORGANIC MATTER AND FOREIGN SUBSTANCES. THE SELECT FILL SHALL MEET THE FOLLOWING REQUIREMENTS UNLESS O7HERWISE APPROVED BY A PROFESSIONAL ENGINEER FOR USE W1 THIN THE LEACHING AREA: THE SELECT FILL SHALL NOT CONTAIN ANY MATERIAL LARGER THAN 774REE (3) INCH SIEVE. UP TO 45X OF THE DRY WEIGHT OF 774E REPRESENTA77VE SAMPLE MAY BE RETAINED ON 774E k#4 SIEVE (THIS IS 774E GRAVEL PORTION OF THE SAMPLE). 774E MATERIAL THAT PASSES THE #4 SIEVE /S 774AN REWETGHED AND 774E SIEVE ANALYSIS STARTED. THE REMAINING SAMPLE SHALL MEET THE FOLLOWING CR17ERIA: SIE VE SIZE PERCENT PASSING WET SIEVE DRY SIEVE 14 100 100 110 70– 80 70– 100 140 10-50* 10– 75 1100 0-20 0 – 5 1200 0– 5 0– 2.5 *PERCENT PASSING THE 140 SIEVE CAN BE INCREASED TO NO GREATER THAN 75X IF 774E PERCENT PASSING 774E J100 SIEVE DOES NOT EXCEED 10% AND THE 1200 SIEVE DOES NOT EXCEED 5r SEPTIC SYSTEM DESIGN THE SEPTIC SYSTEM DESIGN /S BASED ON A PERCOLATION RATE OF LESS THAN 10.1 MIN11N AND A 3 BEDROOM HOUSE, 774E REQUIRED EFFECTIVE LEACHING AREA IS 495 SQ.FT. THE LEACHING SYSTEM SHALL CONSIST OF 2 ROWS Of 4' WIDE, 83 FEET LONG LEACHING TRENCHES PROVIDING AN EFFEC77VE LEACHING AREA OF 495 SQ. FT. ELEVATIONS OF THE SEP77C SYSTEM SHALL BE ADJUSTED IN THE FIELD SO THAT THE FLOW LINES OF THE LEACHING TRENCHES ARE NOT MORE THAN 24 INCHES BELOW EXISTING GRADE. MLSS ANAL PSIS: NO RES7R1C77VE LAYER PER HEALTH DEPARTMENT NO MLSS ANALYSIS REQUIRED UNDERGROUND OIL TANKS ARE NOT PERMITTED. 1 1/2" DIA. POLYETHYLENE FORCE MAIN, PER WAL 774 CODE TABLE 2D MANHOLE TO GRADE , FINISHED GRADE-% CL- U CHECK VALVE 90' ELL. HEAVY DUTY SUBMERSIBLE SEWAGE PUMP PUMP REMOVAL CHAIN PROVIDE 3.5' COVER PER HEALTH CODE a PIPE FROM SEPTIC TANK co 2 I -.-�--�---ter-- _ STEEL FLOA T ' SUPPORT STRAP 6e- 12" EL 99.00 1000 GAL. PRECAST f CONCRETE PUMP CHAMBER FLOAT, TYP. ON–OFF STORAGE 90 GAL SEWAGE PUMP,DETAIL NOT TO SCALE NOTES: THE CONDI TIONS OF APPROVAL OF THE SUBDIVISION ARE A PART OF THIS PLAN. THE OWNER AND BUILDER SHALL READ AND BECOME FAMILIAR WITH 774E CONDITIONS. ALL DEVELOPMENT AND CONSTRUCTION ACTI VI TIES SHALL COMPLY W774 THE SAID CONDITIONS. 774E PROPOSED TOP OF FOUNDATION (TOP FDN.), BASEMENT FLOOR (BSMT. FLR), GARAGE FLOOR (GAR. FLR.) AND GRADING SHOWN ON THIS PLAN SHALL BE REVIEWED /N 714E f1ELD BY THE OWNER, BUILDER AND ARCH17E-CT PRIOR TO C0NS7RUC770N TO INSURE CONFORMANCE TO THE ARCH17ECTURAL PLANS AND CONCEPTS ANY ADJUSTMENTS TO THE PROPOSED ELEVA 77ONS OR GRADING SHALL BE REVIEWED WI774 THE ENGINEER AND 774E HEAL774 DEPARTMENT TO INSURE PROPER FUNCTION OF 774E SEPTIC SYSTEM AND DRAINAGE: PRIOR TO ANY EXCAVATION OR GRADING ON 714E SITE, THE CONTRACTOR SHALL VERIFY THE LOCATION OF ALL UNDERGROUND UTILITIES BY CONTACTING TIME CONNEC77CUT UNDERGROUND UTILITY PROTECTION PLAN FOR U77UTY MARK—OUT (7EL.1-800-922-4455) PRIOR TO THE START OF CONS7RUC770N. STRIPPING OR GRADING. SEDIMENT BARRIERS SHOWN ON 774IS PLAN SHALL BE INSTALLED IN ACCORDANCE WITH THE SPECIFICATIONS AND DETAILS OUTLINED IN THE CONNECTICUT GUIDELINES FOR SOIL EROSION AND SEDIMENT CONTROL, SECOND PRINTING, JANUARY 1988. THE BARRIERS SHALL REMAIN 1N PLACE AND BE PROPERLY MAINTAINED UNTIL ALL UPS7REAM AREAS ARE STABILIZED TO THE SA77SFAC77ON OF THE ENVIRONMENTAL PLANNER. AT THE REQUEST OF THE ENVIRONMENTAL PLANNER, ADDITIONAL EROSION AND SEDIMENTi4770N CONTROL MEASURES SHALL BE INSTALLED TO ADDRESS FIELD CONDITIONS ALL DISTURBED AREAS WHICH ARE TO BE STABILIZED W1 TH VEGETATIVE COVER SHALL BE TOPSO/LEO, FERTILIZED, SEEDED AND MULCHED IN ACCORDANCE WITH THE CONNECTICUT GUIDELINES FOR SOIL EROSION AND SEDIMENT CONTROL, SECOND PRINTING, JANUARY 1988. ALL UNDERGROUND U77UTY (ELECTRIC, TELEPHONE, CA 7V, ETC.) INSTALLATION SHALL PROVIDE FOR EFFECTIVE EROSION AND SEDIMENTA TION CONTROL TO THEIR POINT OF CONNECTION. INSPECTION BY THE TOWN STAFF /S REQUIRED PRIOR TO 774E ISSUANCE OF A CERTIFICATE OF OCCUPANCY. 774IS INSPECTION EVALUATES COMPLIANCE TO THE APPROVED PLOT PLAN AND THE PERMANENT STABILIZATION REQUIREMENT. 774E BUILDER SHALL NOTIFY THE TOWN UPON COMPLETION OF PERMANENT STAB/UZA TION A CERTinCALE OF OCCUPANCY SHALL NOT BE ISSUED PRIOR TO ADEQUATE S17F STABILIZATION AS DEIERM/NE0 BY TOWN STAFF. ALL DRIVEWAY SMOULDERS SHOULD BE STABILIZED IMMEDIA TEL Y UPON COMPLETION OF ROUGH GRADING. THE DRIVEWAY ROADBED SHOULD BE STABILIZED WITH COMPACTED GRAVEL OR AGGREGATE AS SOON AS POSSIBLE. TOPSOIL AND/OR EXCAVATED SUBSOIL SHOULD BE STOCKPILED W117-I/N 714E AREA OF DISTURBANCE /F NOT USED FOR ON S17E REGRADING. EACH STOCKPILE SHALL BE RINGED WI7H SEDIMENT BARRIERS AND STABILIZED AS DIRECTED BY 774E ENVIRONMENTAL PLANNER. LUMBER AND BUILDING MATERIAL STOCKPILES, VEHICLE PARKING AND MOVEMENT SHALL BE CONFINED TO THE AREA OF DISTURBANCE. THE BUILDER SHALL PROVIDE A DUMPSTER FOR STORAGE AND/OR DISPOSAL OF ALL CONSTRUCTION WASTE. THE CON7RACTOR SHALL VERIFY THE FOUNDATION DIMENSIONS ANY CONFLICTS SHALL BE RESOLVED BY 774E ENGINEER. SOIL TEST DATA Uncas Health District SITE INVESTIGATION FOR SUBSURFACE SEWAGE DISPOSAL Owner. Robert Kmiewsld Location: 42 Hidden Acres Deeu Teat Hole Data/Soil Descriptions DATE: 8-25-05 (Record All Test Holes) Test Hole: #. I Test Hole # 2 Test Hole # 3 Test Hole # 4 5 04" Topsoil 0-4" Topsoil - 0-4" Topsoil 0-5" Topsoil 4-23" Brown sandy 4-29" Brown sandy 4-55" Brown sandy 5-27" Brown sandy loam loam loam loam Time 23-75" Grey sandy till 29-86" Grey sandy till 55-74" Grey sandy till 27-85" Grey sandy till Mottling. — Mottling: -- Mottling: Mottling: -- GW: GW: -- GW: — GW: Ledge:--- Ledge: -- Ledge: Ledge: Roots: Roots: Roots: 1 Roots: Restrictive: --- Restrictive: -- Restrictive: =- Restrictive: --- Comments: Groundwater Table: (Near max, below max, etc.) Below max Percolation Test Data Date: 8-26-05 Perc # 1 Pere Rate: 4 mm/mch Pere # Pert -Rate: mm/ D the 26" the Presoak time. 3:30 8-25-05 Presoalc –••--------•– Time Reading Time Reading Time Reading Time Reading 9:39 1925" TREE./SHRUB CO .1:KV j Z 1< U LIGHT POLE 3�E BUILDINGS a 9:47 25.5" S1EPS/HATCHWAY MC:33 CANG PAVEMENT C — — — — — — CONCRETE PA VEMENT-------------- BI T PA►�uEnir _ B17UMINOUS PAVEMENT MEN 9:52 27.25" STORM SEWERS —� r r FOUNDA TION DRAIN F F u ev CURTAIN DRAIN cs ca 10:10 31.75" SEP77C TANK ❑ D1S7R/BU77ON BOX ❑ LEACHING TRENCH —� INFX 7RA TORS �'p 7EST PIT LOCATION oKELL� SWELL SEDIMENT BARRIER "'� -•. CONSTRUCTION ENTRANCE SOIL STOCKPILE TA ABBRE96 TIONS CONC, CONCRETE BIT. BI 77JMINOUS Comments Soil Moisture ( High, medium, low, etc.) OBSERVATION PITS: DATE: 8-12-05 WATER TABLE: below max SOIL DESCRIPTIONS Test Hole # F Test Hole # ` A Test Hole # 6 Test Hole # 0-86" Unsuitable Fill 0-67" Unsuitable Fill 0-84" Unsuitable Fill PROPERTY LINE –••--------•– 67-104" Topsoil GROUND CONTOURS 2 98 +101.25 SPOT ELEVA 7701V 222.2 N 7REE UNE ' TREE./SHRUB Test Hole # Location, Depth Ledge Water Mottling 1 See map 86' --- --- --- 2 See map 104" --- --- --- 6 See map 84" --- --- --- NOTES 1. ALARM SHALL BE AUDIO do VISUAL AND SHALL BE LOCA TED IN HOUSE. 2. FL OA T CONTROL SWI TCHES SHALL BE USED (NO MERCURY) J. THE PUMP SHALL MEET THE FOLLOWING REQUIREMENTS. - A. HEAD — HEAD— 10' OR LESS TO 25' OR MORE — GPM = 10 MIN. B. DESIGNED FOR SEWAGE C. SOUDS HANDLING 3/4" 4. EXTRA ELECTRIC WIRE SHALL BE PROVIDED SO 774AT 714E PUMP AND CONTROL CAN BE REMOVED FROM THE CHAMBER W774OUT DISCONNECTING. 5. PUMP CHAMBER SHALL BE WA TERPROOF. 6. CHAMBER SHALL BE ANCHORED IF 774E BOTTOM OF THE CHAMBER 1S BELOW 774E WATER TABLE. Z ELECTRIC SHALL BE IN ACCORDANCE WITH ELEC7RIC CODE, NOTE.* INSIDE OF TANK IS AN EXPL09W ENVIRONMENT. 8. *SET HORIZONTAL WCATION OF INLET do OUTLET PER PLAN 9. 2'--6" MIN. COVER IS REQUIRED T 4 PREVENT FLOTATION. 126 126 124 122 120 118 SECTION A -A SCALE. 1 = 2' VERTICAL 1"--20` HORIZONTAL LEGEND EXIS77NG PROPOSED 0 IRON PIN O ■ CONCRETE MONUMENT O N PROPERTY LINE –••--------•– ABUTTING PROPERTY LINES ------------- GROUND CONTOURS 2 98 +101.25 SPOT ELEVA 7701V 222.2 N 7REE UNE ' TREE./SHRUB CO .1:KV j Z 1< U LIGHT POLE 3�E BUILDINGS a ROOF OVERHANG i r ---j j t] S1EPS/HATCHWAY MC:33 CANG PAVEMENT C — — — — — — CONCRETE PA VEMENT-------------- BI T PA►�uEnir _ B17UMINOUS PAVEMENT MEN SCLC BITUMINOUS CURB :C8 ••l�D D STORM SEWERS —� r r FOUNDA TION DRAIN F F u ev CURTAIN DRAIN cs ca UTILITIES (ELEC, 7EL, TV) _U_U O O SEP77C TANK ❑ D1S7R/BU77ON BOX ❑ LEACHING TRENCH —� INFX 7RA TORS �'p 7EST PIT LOCATION oKELL� SWELL SEDIMENT BARRIER "'� -•. CONSTRUCTION ENTRANCE SOIL STOCKPILE TA ABBRE96 TIONS CONC, CONCRETE BIT. BI 77JMINOUS Wl'_K WALK VOL. VOLUME PG. PAGE N11F NOW OR FORMERLY BCLC 817UMINOCIS CONCRETE UP CURB GC GRANI7E CURB T.F. TOP OF FRAME T. G. TOP OF GRA TE INV. INVERT X11 F.L FLOW LINE SAW SANI TAR MANHOLE C.B. CA TCH BASIN A.K.A. ALSO KNOWN AS F. Y. FRONT YARD S Y. SIDE YARD R Y. REAR YARD RET. RETAINING EXIST. EXISTING HYD. HYDRANT moll HELCO HARTFORD ELECTRIC LIGHT COMPANY CL&P CONNECTICUT LIGHT do POWER WL WETLANDS TOP FND. TOP FOUNDA 77074 ELEVA TION BSMT. FLR. BASEMENT FLOOR ELEVATION GAR. FLR. GARAGE FLOOR ELEVATION PLA PRIMARY LEACHING AREA RLA RESERVE LEACHING AREA :0 Eli, 0 FIJI Asan SECTION A -A SCALE. 1 = 2' VERTICAL 1"--20` HORIZONTAL LEGEND EXIS77NG PROPOSED 0 IRON PIN O ■ CONCRETE MONUMENT O N PROPERTY LINE –••--------•– ABUTTING PROPERTY LINES ------------- GROUND CONTOURS 2 98 +101.25 SPOT ELEVA 7701V 222.2 N 7REE UNE ' TREE./SHRUB CO .1:KV j Z 1< U LIGHT POLE 3�E BUILDINGS a ROOF OVERHANG i r ---j j t] S1EPS/HATCHWAY MC:33 CANG PAVEMENT C — — — — — — CONCRETE PA VEMENT-------------- BI T PA►�uEnir _ B17UMINOUS PAVEMENT air. culla SCLC BITUMINOUS CURB :C8 ••l�D D STORM SEWERS —� r r FOUNDA TION DRAIN F F u ev CURTAIN DRAIN cs ca UTILITIES (ELEC, 7EL, TV) _U_U O O SEP77C TANK ❑ D1S7R/BU77ON BOX ❑ LEACHING TRENCH —� INFX 7RA TORS �'p 7EST PIT LOCATION oKELL� SWELL SEDIMENT BARRIER "'� -•. CONSTRUCTION ENTRANCE SOIL STOCKPILE TA ABBRE96 TIONS CONC, CONCRETE BIT. BI 77JMINOUS Wl'_K WALK VOL. VOLUME PG. PAGE N11F NOW OR FORMERLY BCLC 817UMINOCIS CONCRETE UP CURB GC GRANI7E CURB T.F. TOP OF FRAME T. G. TOP OF GRA TE INV. INVERT F.L FLOW LINE SAW SANI TAR MANHOLE C.B. CA TCH BASIN A.K.A. ALSO KNOWN AS F. Y. FRONT YARD S Y. SIDE YARD R Y. REAR YARD RET. RETAINING EXIST. EXISTING HYD. HYDRANT W.G. WA TER GA 7E' HELCO HARTFORD ELECTRIC LIGHT COMPANY CL&P CONNECTICUT LIGHT do POWER WL WETLANDS TOP FND. TOP FOUNDA 77074 ELEVA TION BSMT. FLR. BASEMENT FLOOR ELEVATION GAR. FLR. GARAGE FLOOR ELEVATION PLA PRIMARY LEACHING AREA RLA RESERVE LEACHING AREA V rte, N rz V ♦ ``' LO C) 60 o onpao o " V O � 1cl�a N W k- w o CO .1:KV j Z 1< U Z � v a C'n O „ OZ o to bc W Q JUj 4 �o� Q 4 V W Q J .1 r - ?OBER JOHNSTON, P.E. #8961 fits document is on instrument of professional service, and shall not be used, In whole or In part for any project other than for which It was created without the express written consent of DUrTON & JOHNSTON, LLC Any unauthorized use. reuse, modilkotion or conversion of this document shall be at the users sole risk without lkbi#lty or legal exposure to DUTTON & JOHNSTON, LLC. O 2001 — DUTTON & JOHNSTON, LLC. Q rte, Z V) Iwo>z W V Z QrzV O � 1cl�a � 4 w �w J REVISIONS: 12/2212005 ~ TOWN COMMENTS 05/24/2006 ---SEPTIC LEACHING AREA DATE: 11/09/2005 SCALE: AS NOTED SHEET 3 of 3 A -04-087—D 1 FILE.• 04087—PLOT PLAN.DWG