Loading...
HomeMy WebLinkAboutPlot Plan- LEGEND STONE WALL FENCE x x IRON PIN FIRM/COMP SILT LOAM SUBSOIL MEREST ONE GREY -BROWN ROOTS THROUGHOUT LEDGE OR ROCKS - - EXISTING CONTOUR - - - - - - PROPOSED CONTOUR TIME UTILITY POLE -� TEST HOLE 6i PERC. TEST SILTY SAND & S'TONE, GREY SILT FENCE l ` MAY BALE [- ---� CONFIRMING TEST NOL E � rO EX rEN0 6 .9EZ Ow GROUND LEVa EXcA w rE 6 "z 6 " r>tEA:)r TV SURr AASRIC 4 CONIC" C r WXF/L L 811! Jrdpnogp Detail ,4r-,.roPso1L^N., AI/N. 6"a vAR�e-s F TER rR/C AM •►. 19Y tO 'OIL ♦j o�i i �° s �c•� 6i f►9' S 4' • i *,foe A 6 •a / &RoK N STONE= �' I At 48 TRENCH DErA& T 6" TEST FiO LES WITNESSED PY (? . W . GFIRWICK ENGINEERING & TOWN SANITARIAN ON 3;'8/95. TH 8A 0-611 TOPSOIL, & HUMUS 6-60 FIRM/COMP SILT LOAM SUBSOIL 8- INV. GREY -BROWN ROOTS THROUGHOUT 60-80 SILT IN FINF/MED SAND POSSIBLE LEDGE 80", MOTIJA NG _11" SEEPAGE 41 " . TH 8B TIME 0-6" TOPSOIL & HUMUS 6-48 FIRM/COMP SILT I 0AM SUBSOIL 48-75 SILTY SAND & S'TONE, GREY POSSIBLE LEDGE 75' MOTTLING 27"1 SEEPAGE 50' 111 8C 0-6" TOPSOLI, & HUMUl; 6-16 ('OMPA( T GREY S I I1' 16-23 R ROWN S I LT LOAM 23-72 GREY MED/COARSI, SAND & S'TONF POSSIBLE LEDGE '72", MOTILIN(-, 1 -)" , SEEPAGE, 46". TH 8D 0-6" TOPSOIL & FIIJMUS 6-41 COMPACT BROWN, S I LT LOAM 41-90 GREY MED SAND f, STONE NO LEDGE, MOTTLING 34", ROOTS TO 41", SEEPAGE 47". HIGH LE EL (HsLs) i OVERFLOW 130 NORTH TEST HOLES 25 & 26 WITNESSED BY TOWN SANITARIAN ON 1/6/88. TH 25 0-6" TOPSOIL 6-22 VERY FINE SANDY SILTY LOAM 22-50 GREY SILTY LOAM 50-80 GRAVEL NO LEDGE, MOTTLING 30", WATER 53". TF1 26 0-6" TOPSOIL, 6-36 VERY FINE SANDY SILTY LOAM 36-43 GREY SANDY LOAM 43-72 SANDY GRAVEL NO LEDGE, MOTTLING 41", WATER 69". LOT 6-8 AREA = 43, 428 S. F l.0 AC. PERC TEST PERFORMED BY D.W. GERWICK 136 134 132 130 128 126 124 122 ` \ \ t 260-67' 120 138 f • 2.48 \ \ 1 SILT FENCE` \ ` FOOTING DRAIN OUTLET SOLID 4"PVC (SCH 40) W/TIGHT JOINTS ` T. H. 25 \ BUILDING LINE -- PC \ >/ � \ � \` \N ` T.H. N ` \ H.L. GAP �?°' \ 27 \ \ ?\ y FL*= /3Z.5 D i i 1 4„SOLID PROPOSED-?4Iv PVC (SDR'35) r ' I ' \ I gay H O u SE 111- , \ PRAPOSED I 1 61 1 2 7' O q" /. P/P 1 WELL � I E UAL I T. C \ F� O ` r . ' rop fDN= /34.0 /4 f' i 8D vL 3 1- _ ' / M/N. 10250 GAL. SEPTI ' TANK BUILDING LINE � � 1 I 1 � � � � I 323.74' 144 142 1 138 136 134 /32130 128 /26 /24 75 C. -I 130 -EXISTING GRADE 12' 15' 125 125 I I - FINISHED GRADE 120 120 GRAVEL FILL TO REPLACE TOPSOIL a SUBSOIL AS REO'D BY TOWN SANITARIAN. 115 PROFILE A -A VERT. = I"= 5' HORIZ.= I "= 10' O APPROX L OC. WELD L or 6-7 SEPTIC__. SYSTEM INVERTS A- MIN. ENGINEERING ON 3/8/95. FOUNDATION = 126.50 8- INV. PT 8A DEPTH 24". OUT OF TANK = 125.50 TIME MEAS. DROP RATE E - INV. 2:50 12" -- - 2:55 14 1/2 2 1/2 2.00 3:00 16 1/2 2 2.50 3:05 18 1/4 1 3/4 2.85 3:10 19 1/2 1 1/4 4.00 3:15 20 1/2 1 5.00 3:20 21 1/2 1 5.00 LESS THAN 3" REMAINING. W o a � b o� C � QJ i �o rL Q BENCHMARK TOP OF MON. EL EV = 1 /8.96 136 134 132 130 128 126 124 122 ` \ \ t 260-67' 120 138 f • 2.48 \ \ 1 SILT FENCE` \ ` FOOTING DRAIN OUTLET SOLID 4"PVC (SCH 40) W/TIGHT JOINTS ` T. H. 25 \ BUILDING LINE -- PC \ >/ � \ � \` \N ` T.H. N ` \ H.L. GAP �?°' \ 27 \ \ ?\ y FL*= /3Z.5 D i i 1 4„SOLID PROPOSED-?4Iv PVC (SDR'35) r ' I ' \ I gay H O u SE 111- , \ PRAPOSED I 1 61 1 2 7' O q" /. P/P 1 WELL � I E UAL I T. C \ F� O ` r . ' rop fDN= /34.0 /4 f' i 8D vL 3 1- _ ' / M/N. 10250 GAL. SEPTI ' TANK BUILDING LINE � � 1 I 1 � � � � I 323.74' 144 142 1 138 136 134 /32130 128 /26 /24 75 C. -I 130 -EXISTING GRADE 12' 15' 125 125 I I - FINISHED GRADE 120 120 GRAVEL FILL TO REPLACE TOPSOIL a SUBSOIL AS REO'D BY TOWN SANITARIAN. 115 PROFILE A -A VERT. = I"= 5' HORIZ.= I "= 10' O APPROX L OC. WELD L or 6-7 SEPTIC__. SYSTEM INVERTS A- MIN. INV. AT FOUNDATION = 126.50 8- INV. INTO TANK = 125.75 C- INV. OUT OF TANK = 125.50 0- INV. TRENCH I = 122.75 E - INV. TRENCH 2 = 12 1. 00 1 i T.H. 8 B / 1 1� r m P 1 � , �1 I I I o ,T. H. \ 26 1 BOX 1 1 1 � T.H. < 1 m I ' I 1 1 122 1 7/20 1 118 4" PERFORATED PVC PIPE IN 12"x48" TRENCHES W/ 1 "S TONE TN/S PLAN IS 1 HE AR/lsA'VAL *OW OF THE ENGINEER M'hV RETAINS SOLE Oi1'AER&Y/P. ALL COPIES ARE AOR THE USE Of rw a- AENT. NO cons OF THIS a AN mAY m MADE wl rHal r 7NE P!rmlSS/4N OF THE soveaEER. my IS TN/S P- AN GoiI1IS/QERfED VALID W/TfEwr oRnI AL sEAL Aw ,76AW TLPE. C 11 (V. 113.35 1 . Contours from field survey by David Coonrod, L.S. 2. Proposed house is a four bedroom house. Basis of design is for four bedrooms with a design perc rate of 1.0 - 10.0 min./in. System area required is 660 s.f. and is supplied as follows: 2 rows of 110 1 . f . of 4 'wide x 12" trenches = 660 s.f. ------------- Total Leaching Area = 660 s.f. MLSS Required = HF(26) x PF(1.2) x FF(2.0) = 62' MLSS Supplied = 120' A 100$ reserve area has been supplied. 3. All topsoil, stumps, and boulders must be removed from the area of the system. 4. Town sanitarian must_ be notified before any pipes or appurtenances are backfilled. 5. There are no wells within 75' of this system. 6. Gravel fill shall be used to replace all topsoil and subsoil as required by the Toon Sanitarian. Gravel shall be placed in 6"-8" lifts and shall be mechanically compacted for both the primary and reserve areas, as shown on this plan. 7. Gravel fill shall have a maximum of 5* fides passing a Standard No. 200 sieve and a maximum of 109 passing a No. 100 sieve. All gravel fill shall be approved by the Town Sanitarian prior to deposition. Gravel fill in place shall have a pert rate equal to or faster than the design rate. 8. There shall be no cuts within 50' of the downhill side of the system or within 25' of the sides of the system. There shall be no stumps or boulders buried within 50' of the downhill side of the system. There shall be no footing drains or stone placed around or under any proposed structure within 50' (down gradient) of the system. 9. Should any significant variations from test hole data shown (ledge, water, mottling, soil type) be discovered by the contractor, the engineer shall be notified prior to construction of the system. 10. System area and elevation shall be staked out by the engineer or surveyor prior to construction. 11. In general, all construction practices, as per the State of Connecticut Department of Health Services guidelines, shall be adhered to. The following outlines some of the major procedures, but do not relieve the contractor from full compliance due to their lack of mention below: A. All topsoil, stumps, and boulders shall be removed from the area of the system and system fill. No machinery or vehicles shall be allowed on the exposed native soil. Stripping should rent take I) I ac e %,i thi n 48 s tanulrly JJUU(11 c ti . .� B. The earth shall be scarified prior to fill - 116 placement. Gravel fill shall meet the specifications of Note 7 and be placed in accordance with Note 6. C. No trucks or heavy machinery shall be allowed in the stripped area until 12" of gravel fill is in place. 12. Tank manhole risers may be required to within 12 inches of finished grade if top of septic tank is greater than 12 inches below grade. ROPOSED SEPTIC SYSTEM DESIGN CHRIS 61 PAM KINDER LOT 6-8 GLEN CRAG ROAD MONTVILLE, CONNECT/CUT SCALE l"= 20' MAR. 23. /995 REY. 3-/-95 5-102-93 D. W. GERWICK ENGINEER/NG P. 0. BOX 539 l7 AVERY LANE WATERFORD , CONNECTICUT 203-442-2201 J. N. 9503 - I 13