Loading...
HomeMy WebLinkAboutPlot Plan1 E-A) V. L N. 3 vw V APPROX NORTH Iz cu. 10 w1rL1. N C. fmo,v wokllj btt SqVG bte4- S101SIS FOUNDATION CORNER@ - , - 651 FOUNDATION CORNEF@ 89, SEPTIC TANK INLET 131' "D" BOAS 1721 "D"BOA@ 1851 WELL LOCATION 91, LEGEND PROPERTY LINE STREET LINE BUILDING SETBACK GENERAL NOTES 1. BOUNDARY INFORMATION AND INLAND WETLAND LIMITS TAKEN FROM THE LINE APPROVED SUBDIVISION PLAN. THE BOUNDARY IS CERTIFIED CLASS A-2. EXISTING CONTOUR . --� ONTOUR- " '-- PROPOSED PROPOSED CONTOUR DEEP TEST PIT LOC C. PERC TEST LOC D. WETLAND FLAGS BLU PRINTS UNL 75503 FE?OM IE@ 133' 991± 143' 159, 179' 72' 70 76 76 7V - ti WETLANDiS SANITARY ELEVATION DATA SANITARY INVERT AT FOUNDATION: 92.00 DIA SCHEDULE 40 ASTM D1785 OR EQUAL PIPE 1250 GALLON TWO COMPARTMENT SEPTIC TANK INV. 87.25 IN INV. 87.00 OUT 0 32'-4" DIA SDR 35 PVC PIPE MODIFIED HIGH LEVEL OVERFLOW "D" BOX INV. 84.37 IN INV. 84.20 TO TRENCH INV. 84.45 OVERFLOW 30 10'-4" DIA SDR 35 PVC PIPE MODIFIED HIGH LEVEL OVERFLOW INV. 83.07 IN INV. 82.90 TO TRENCH INV. 83.15 OVERFLOW "D" BOX INV. 81.77 IN INV. 81-60 OUT 75' LONG x 36" WIDE x 18" DEEP STOA LEACHING T ENCH 12 BOTTOM OF TRENCH ELEV: 83.20 81.90 1 80.60 TRENCH INV. 84.20 1 82.90 81.60 12 lr[rc 0 006f. A10 lyPtV#jry 3c> polale SYNTI-DTIC. FABRIC 10*0.C. MAX. FI LTF-FR FENCE (TYP) (E N V I PO F e NC F_ (M I P -A F-( OR APPROVED WOOD posts COMPACTED BACKFILL % GRADE W- MIN. DePTH UNDISTURBED GPOUNO SEDIMENT FENCE DETAI PERF, DIST PIPE 1IRF, I L C RO. 41 ..LEvEL CUT 90`* ELBOW 11 To P 0,4DE. TO p R 3"* DIFF. To NEX T •IQ j-, OWER TRENCH MODIFIED HIGH LEVEL OVERFLOW I'D" BOX NOT To iaLE- OL Af L tine 311 Outlet ira fv1'Q"•1'6"P311 UqWd hid -Depth C4ruwdon yj P49ig Depth VJR4qWr*d l Caty I pa pad %ldth or Depth NMI: CLEANOUT MANHOLES AND ALL BAFFLED INSPECTION MANHOLES SHALL BE LOCATED AT A DEPTH NOT GREATER THAN 120 BELOW FINAL GRADE TtYPIC4k F4CIIINO ZRENCII. SECTION (N. r. S..1 O Q,. • I VR 0AT11 r 1qly4r O's A�IW. AROYI* OR01WO YArl*R 410 r*rZ IWC) a411N. NOTE: A.LAYER OF NON -WOVEN FILTER FABRIC SHALL BE PLACED OVER ALL STONE BEFORE BACKFILLING. MINIMUM AVERAGE ROLL VALUES FOR FABRIC SHALL BE 1-5 OZ/YD2(PER ASTM D-3776), A PERMITTIVITY OF 1-OSEC-I(PER ASTM D-4491) AND A TRAPEZOID .TEAR OF 15 LBS(PER ASTM D-4533) .. DEEP TEST plT DATA PIT A 0-811 TOPSOIL 8-29" SUBSOIL 29-81" SANDY GRAVEL NO LEDGE NO WATER NO MOTTLING PITS 0-611 TOPSOIL 6-27" SUBSOIL 27-87" SANDY GRAVEL NO LEDGE NO WATER NO MOTTLING PERCOLATION TEST HOLE DUG TO A 38" DEPTH PRESOAK AT 1:45 PM REFILL AT 3:00 PM TIME READING 3:00 22 1/2" 3:10 25 1/4" 3:20 27" 3:30 28 1/2" 3:40 3011 3:50 31 1/2" MIN PERC RATE: 6.7 MIN/INCH A. GENERAL NOTES 1. BOUNDARY INFORMATION AND INLAND WETLAND LIMITS TAKEN FROM THE APPROVED SUBDIVISION PLAN. THE BOUNDARY IS CERTIFIED CLASS A-2. B. 2. THE DEEP TEST PIT DATA ON THIS PLAN WAS WITNESSED AND RECORDED BY RAYMOND ANDREWS, UNCAS HEALTH DISTRICT, AND GARY J. WINALSKI, C. PE, ON MARCH 29, 1999. THE PERCOLATION TEST WAS WITNESSED AND D. RECORDED BY GARY J. WINALSKI ON MARCH 29, 1999. 3. THIS LOT WAS TOPOED IN THE AREA OF THE HOUSE AND SEPTIC SYSTEM, THE TEST PITS LOCATED AND A BENCHMARK SET BY DIETER & GARDNER, PIT C 0-8" TOPSOIL LAND SURVEYORS, ON MARCH 31, 1999. 8-3011 SUBSOIL THE ELEVATION DATUM IS ASSUMED. 30-83" 'SANDY GRAVEL SYSTEM DESIGN' NO LEDGE 4. AT THE TIME OF THIS DESIGN THERE WERE NO EXISTING WELLS WITHIN 75' OF NO WATER THE PROPOSED SEPTIC SYSTEM AND THERE WERE NO EXISTING SEPTIC NO MOTTLING SYSTEMS WITHIN 75' OF THE PROPOSED WELL LOCATION. PIT D 0-9" TOPSOIL 5. ANY TOPSOIL OR ORGANIC MATERIAL ENCOUNTERED BELOW THE TOP OF THE 9-28" SUBSOIL LEACHING TRENCH SHALL BE REMOVED AND REPLACED WITH FILL SUITABLE 28-80" -SANDY GRAVEL FOR SEPTIC SYSTEM INSTALLATION. FILL SHALL BE FREE OF ORGANIC NO LEDGE MATERIAL AND. SHALL HAVE LESS THAN 5% FINES PASSING THE #200 SIEVE. NO WATER TEE -PEE GALLERIES. NO MOTTLING 6. PERFORATED PVC FOUNDATION DRAINAGE SHALL BE LOCATED A MINIMUM DISTANCE OF 25' FROM THE SEPTIC SYSTEM. THE SOLID WALL PVC FOUNDATION OUTLET DRAIN SHALL BE LOCATED NO CLOSER THAN 10' FROM THE SEPTICSYSTEM AND SHALL MEET TABLE 2-C OF THE CODE. A RODENT PROOF COVERSHALL BE PROVIDED ON THE FOUNDATION OUTLET DRAIN AT "DAY LIGHT." 7. OWNER/APPLICANT: JOSEPH JANIERO 16 PEACH TREE HILL AVE LEDYARD, CONN. 06339 (860) 464-7435 8. ENGINEER: GARY J. WINALSKI 9 HERITAGE DRIVE STONINGTON, CONN 06378 (860) 535-2283 ZONING COMPLIANCE TABLE REQUIRED PROVIDED FRONT YARD SETBACK 50' 58 SIDE YARD SETBACK 15, 301 A. SANITARY DESIGN CRITERIA PROPOSED FOUR BEDROOM HOME WITH FULL WALKOUT BASEMENT. NO TUBS GREATER THAN 100 GALLONS IN SIZE. B. 1250 GALLON TWO COMPARTMENT SEPTIC TANK REQUIRED BY CODE AND PROVIDED C. DESIGN PERCOLATION RATE: 1.0 TO 10.0 MIN PER INCH D. MINIMUM LEACHING SYSTEM SPREAD: NOTE: DOES NOT APPLY, ALL RESTRICTIONS GREATER THAN 60" IN DEPTH E. EFFECTIVE LEACHING AREA REQUIRED PER CODE: 660 SF F. 36"WIDE)(le DEEP STONE LEACHING TRENCHES SELECTED FOR LEACHING SYSTEM DESIGN' EFFECTIVE LEACHING AREA PROVIDED PER LF PER CODE: 3.0 SF MINIMUM LENGTH OF LEACHING TRENCH REQUIRED: 660 S)r/l 5F= 2201 G. EFFECTIVE LEACHING AREA PROVIDED 3-75' LONG TRENCHES, 3 x 75'x 3 SF/LF= 675 SF H. 100% RESERVE AREA REQUIRED AND PROVIDED NOTE: RESERVE AREA LAYED OUT FOR TWO ROWS, 48' LONG, TEE -PEE GALLERIES. EFFECTIVE LEACHING AREA PROVIDED PER LF PER CODE: 71 SF EFFECTIVE LEACHING AREA PROVIDED: 2 x 48x 7.1 SF/LF= 681.6 SF of co No. 9671 004, 04 * SII Al, CO pop PROPOSED ENGINEERED SEPTIC SYSTEM DESIGN PLOT PLAN LOT & 15 GLEN CRAG PLACE MONTVILLE, CONNECTICUT SCALE: V 301 APRIL 1999 MADE IN U.S.A.