HomeMy WebLinkAbout302.1IF -1
LEGEND
PROPERTY LINE
BUILDING LINE
ANGLE POINT
Q IP FND IRON PIN OR PIPE FOUND
® MON FND MONUMENT FOUND
Q Dhi FND DRILL HOLE FOUND
• IP 5ET
IRON PIN TO BE 5ET
■ MON SET MONUMENT TO BE 5ET:'
Dhi 5ET DRILL HOLE TO BE SET ROAD
BUTLERTOWN
STONE WALL -- �"-- — --- �
__--
x WIRE FENCE JET `- ire, :>� 230
. 51LTFENCE OR hAYBALE5�) _
230 ---- ' �''r'� ' ' BIT. DRIVEW YA --+�►-
500 - EXISTING CONTOUR 1--'
EDGE WOODS OR CLEARING IP FND S `.30'54'06"E 181.56' ..MON FND
_---- — /
23 - ..
3
0 S 33' 33' 05"E 234.30' .'
2 ... "' _ --- - 228
- I'P FND ` DOVE EXISTING SEPTIC TANK
TO NEW LOCATION 227X32
228 ADDITION L TEST KITS 21 & 2- 2'Z� ®TEST PIT#18 TEST PIT#2o
�(m� BES D G AND PERC. TEST"PERFORMED °O
n
BE FOR NY WORK IS STAR TEST PIT#17 27X5 TEST PIT#19 j T r"f i II- -- 226 89 CONC. DRIVEWAY 4
• PROP. ® TAN 115
�. TEST PIT#21 _ - H'40 -
26 _. - 2 (TIG IPE
2 f �� •t r, �' G -=- --- - --n EXISTING
Ilk do 6 C�L
M[,} WELL
C°
---.. �1A - v 226X227 27
226
is 56,
DESIGN NOTES.-
1.
OTES.1. ALL CONSTRUCTION TO CONFORM TO STANDARDS OF THE CONNECTICUT
PUBLIC HEALTH CODE AND TO THE SATISFACTI❑N OF THE TOWN SANITARIAN.
2. THIS SYSTEM HAS NOT BEEN DESIGNED FOR THE USE OF LARGE CAPACITY
(+100 GALLONS), DISCHARGE TYPE BATHTUBS, RESIDENTIAL GARBAGE
DISPOSALS ARE NOT ANTICIPATED FOR THIS DESIGN. IN THE EVENT THAT
SUCH AN INSTALLATI❑N IS CONTEMPLATED FOR THE PROPOSED HOUSE, A
LARGER SEPTIC TANK AND INCREASED LEACHING FIELD CAPACITY WILL BE
REQUIRED,
3. THE DESIGN SHOWN HEREON CONFORMS TO ALL APPLICABLE STATE AND
LOCAL HEALTH CODE REQUIREMENTS AND TO GOOD ENGINEERING PRACTICE.
WE CAN NOT GUARANTEE AGAINST FAILURE DUE TO IMPR❑PER INSTALLATION,
IMPROPER MAINTENANCE OR TO NATURAL PHENOMENA BEYOND THE SCOPE
OF NORMAL FIELD INVESTIGATION,
NOTE:
1. LICENSED SURVEYOR WILL STAKE SYSTEM IN FIELD PRIOR TO
CONSTRUCTION.
2. THE AREA UNDER THE SELECT FILL SHALL HAVE THE TOP SOIL
REMOVED AND INSPECTED PRIOR TO SELECT FILL PLACEMENT.
i
MLSS CALCULATION
HEBRO i\
CT.
25'
FF X PF
= MLSS (FEET)
PROP C.,L. ::C3,
32-5 20 X
1.0 X 1.5
= 30
- 50'
TEST PIT j 19
0"
OFFICE
TF.226.00
10"
o Q
SOIL
18" 54" SUB SOIL
224 --
96" SILTY
PROP ®
TEST SPIT 22 '
;�
54" 100" SILTY CLAY
44"
FL.220.00
54" MOTTLING
80"
WATER
_ __
100" WATER
TEST PIT # 18
_
0"
EXISTING BUILDING
0" 14" LOAM
12"
50" SUB
SOIL
14" 39" SUB SOIL
'=
•
PROPOSE
BUILDING (SLAB)
FFLR. ELEV. 227.41
50"
MOTTLING
- WF#97
39" MOTTLING
4�
WATER
FFLR. ELEV. — 227.41
- -- 222
-- 3 --- --
- --- - __
_� — --- -- --
-- ----- - _ Z.
SEQU"CS QlP 1CrlTY — HOiJSa LOT DLrVBLOP"N!' �1�
.,
_
-
Q o
1.
LIMITS OF DISTURBANCE. Upon approval of individual site plan
t�
-
--�
•
development, the limlt of development shall be establishedln the field
structure, Disturbance limits shall be 25-35 feet
--
for each proposed
�. 220
22
•
beyond the proposed building and shall be bounded by staked haybales or
!ti
222
-
2.
silt fence,
ER❑SI❑N CONTROLS, Area to be disturbed shall be bounded by staked
-.
220
-
.
haybales or slit fence, All erosion controls, Including slit fence and
---WF 9 9
torr ,
,, , enrrF
-----
antitracking pad, shall be Installed and Inspected by the Land Use
- --.� -
10 1
_
- - '�
Planner/ZEO and Wetland Agent Prior To Stumps Being Pulled, Grubbing,
Or Excavation, The Planner/ZEO and Wetland Agent may Modify the
----
erosion control requirement based on field conditions so as to
adequately control erosion and slltatlon from the site.
220 .�
3.
TREES CLEARED . Trees shall be cleared and cut to length and stacked
-
FL.218.00
or removed from site. Then the putting of stumps, grubbing and or
excavatlon will begin,
I WF#1021W
-F WF.# 103
_-
4.
DRIVEWAYS, Alt driveway and driveway shoulders shall be stripped,
graded as shown on plan, and gravelled, All driveway shoulders shall be
R.'PRAP
--
stabilized Immediately upon grading, either by diverting runoff,
LOT 32-5
mulching, or seeding, haybales and silt fence
or other approved measures the same day that cuts are made.
5,
T❑PS❑IL, All topsoil shall be stripped and saved In an area asSQ*FT*
2479396
_
+-�V� 1 Q
-#
_ _-- _-_ _ _
- 21
shown on the Ian or as approved b the Planner and Wetland Agent.
P PP y gWETLANDS
the -in
--
ACRES
NOTE
_4 w
__
WF 1 OS5.6`0-
Topsoil shall not be removed from site except as compliance with
WETLAND
LOCATION WERE TAKEN
FROM THE JLiBL)I '�Il;iv—
__ _"` — —__ 1AL _. _ r 'fir 106
the Zoning Regulations.
PLAN AS
REFERENCED AND WERE
FLAGGED BY RIC1-'4`,RD'-
6.
CONSTRUCTI❑N AND DISTURBED AREA, Excavation and construction shall
SNARSKI
SOIL SCIENTIST.
w -
�--
commence following Inspection and approval of erosion control and
_
_ - �1/_F# 1 07
214
construction of the driveway, The disturbed area shall be so as
COVER Wf NON—MK>IVVEN
to contain runoff within the lot to the greatest extent possible.
12'0_
' 12
FABRIC FR.TER
�
7.
SITES IN WINTER. When a site will be open during the winter Months,
rough grading and 4-6 Inch mulching must occur prior to construction In
EXISTING GRACE
SO' MIN,
- - ------ -
order to minimize erosion and uncontrolled runoff during the winter
/KACE i" SALVAGED TOPS&
r
months,
TO EMI. GRADE LMM SEED � !
8.
DRAINS. Foundation and curtain drains shall be Installed as shown
15'
RADIUS
on the approved plan, ANY CHANGES TO THE L❑CATION OF THE DRAINS OR THE
Q
ADDITIONS OF ANY DRAINS SHALL BE APPROVED BY THE PLANNER AND WETLANDS
Q
O
AGENT PRIOR TO INSTALLATI❑N.
9,
COMPLETE SITE WORK, Finish grading shalt occur as soon as possible
Lj
on all lots where there is potential for erosion and for degradation of
ie"
o
wetlands and watercourses. Lots shall be finish...graded, seeded with
1" BROKEN STONE
APPROVED
¢
CT, D,O.T.
25 MIN.
perennial grasses sultabte for the respective amount of sun or shade and
N" GROUND WATER 48" MIN.
CRUSHED GRAVEL
L7
mulched prior to Certificate of Zoning Compliance,
Z
-
10.
FINAL STABILIZATION. EROSION CONTROLS SHALL BE MAINTAINED ON THE
R
LOT
AS LONG AS THEY ARE NEEDED TO CONTROL EROSION AND SEDIMENTATION.
LEDGE ROCK
_
11.
All E&S controls shall be Inspected on a dally basis and maintained
w
X
Ld
as necessary until all disturbed areas are permanently relegated or
NOT TO SCALE
otherwise stabllized,
DESIGN NOTES.-
1.
OTES.1. ALL CONSTRUCTION TO CONFORM TO STANDARDS OF THE CONNECTICUT
PUBLIC HEALTH CODE AND TO THE SATISFACTI❑N OF THE TOWN SANITARIAN.
2. THIS SYSTEM HAS NOT BEEN DESIGNED FOR THE USE OF LARGE CAPACITY
(+100 GALLONS), DISCHARGE TYPE BATHTUBS, RESIDENTIAL GARBAGE
DISPOSALS ARE NOT ANTICIPATED FOR THIS DESIGN. IN THE EVENT THAT
SUCH AN INSTALLATI❑N IS CONTEMPLATED FOR THE PROPOSED HOUSE, A
LARGER SEPTIC TANK AND INCREASED LEACHING FIELD CAPACITY WILL BE
REQUIRED,
3. THE DESIGN SHOWN HEREON CONFORMS TO ALL APPLICABLE STATE AND
LOCAL HEALTH CODE REQUIREMENTS AND TO GOOD ENGINEERING PRACTICE.
WE CAN NOT GUARANTEE AGAINST FAILURE DUE TO IMPR❑PER INSTALLATION,
IMPROPER MAINTENANCE OR TO NATURAL PHENOMENA BEYOND THE SCOPE
OF NORMAL FIELD INVESTIGATION,
NOTE:
1. LICENSED SURVEYOR WILL STAKE SYSTEM IN FIELD PRIOR TO
CONSTRUCTION.
2. THE AREA UNDER THE SELECT FILL SHALL HAVE THE TOP SOIL
REMOVED AND INSPECTED PRIOR TO SELECT FILL PLACEMENT.
i
MLSS CALCULATION
HEBRO i\
CT.
LOT HF X
FF X PF
= MLSS (FEET)
06237-0497
32-5 20 X
1.0 X 1.5
= 30
TEST PIT # 17
TEST PIT j 19
0"
10" LOAM
0" 18" LOAM
10"
44" SUB
SOIL
18" 54" SUB SOIL
44"
96" SILTY
CLAY
54" 100" SILTY CLAY
44"
MOTTLING
54" MOTTLING
80"
WATER
100" WATER
TEST PIT # 18
TEST PIT #20
0"
12" LOAM
0" 14" LOAM
12"
50" SUB
SOIL
14" 39" SUB SOIL
50"
98" SILTY
CLAY
39 102" SILTY CLAY
50"
MOTTLING
39" MOTTLING
NO
WATER
72 WATER
CONSTRUCTION ENTRANCE
NOT TO SCALE
POST
W -r ate.
1'-4"3=o)W GM
SON COHTEM
FMM YAC
BURY MR TMOCK
� � �: t � ►. •. � 11;1 i�
J&P REFERENCE: U
IMPROVEMENT LOCATION PLAN PREPARED FOR UNDO CONSTRUCTION SILT FENCE BARRIER
32G BUTLERTOWN ROAD MONTVILLE, CONNECTICUT SCALE: I" = 20't
DATE: AUG. 18, 1998
::; TO MY KNOWLEDGff AND BELIEF, THIS MAP 15
TO MY KNOWLED AND BELIEF THIS MAP IS SUBSTANTIALLY GRAPHIC SCALE 5U55TANTIALLY CORRECT A5 NOTED fMEREON.
CORRECT ASN r� HEREON.
20 0 20 40
l TNI -, DPawlt I` h0! ALID 011LI-Y, IF BEAP,
_ PJ EMB( ,_EL- _)P (.F+LURED IIJI ,EHL MID
L)PICM,14i COI ORD ;i+,Ddl,= 11 IPE.
MARK REYNOLDS . E. #19789
CERTIFICATION- IS OT V WITHOUT LIVE SIGNATURE (IN FEET)
AND EEMBOS%b PREM) TYPE SEAL. I Inch = 20 ft.
ROBERT W. HEI15TROM, L.S. #! 3626
■
„
open -
3870B 07 91W
pen --38.0807„w 779 27
IP FND
BUTLUOWN ROAD
H
ROB LSTROM
LAND S VEYING
32 MAIN .
TREET
HEBRO i\
CT.
P.O. B(,
49'7
COLUMBIA, CT.
06237-0497
BOUNDARY
SCALE: 1 ” = 100'
DESIGN CRITERIA
PROJECTED NUMBER FACTORY WORKER GALLONS PER LEACHING AREA
OF EMPLOYES NO SHOWER SQ. FT. REQUIRED
GALLONS PER
DAY
10 X 25 = 0.8 — 312.5
56' 12" GALLERY X 5.9 = 330.4 SQ .FT. PROVIDED
YAP STANDARD NOTES
. TI115 SURVEY 11A5 BEEN PREPARED IN ACCORDANCE
WITH SECTIONS 20-300b- I THRU 20-300b-20 OF THE
REGULATIONS OF CONNECTICUT STATE AGENCIES
"MINIMUM STANDARDS FOR SURVEYS AND MAPS IN
THE STATE OF CONNECTICUT AS ENDORSED BY THE
CONNECTICUT ASSOCIATION OF LAND SURVEYORS, INC.
THE TYPE OF SURVEY PERFORMED IS A IMPROVEMENT
LOCATION PLAN BOUNDARY DETERMINATION tS BASED
ON A RESURVEY OF PROPERTY AND CONFORMS
TO THE A-2 CLASS OF ACCURACY.
2. TOPOGRAPHIC FEATURES, IF SHOWN 11EREON,WERE
PREPARED IN ACCORDANCE WITH CLASS T- 2 .
plpma.d. -Z/2/Lo
5-
IMPROVEMENT LOCATION PLAN
— PREPARED FOR
PATERSON MANUFACTURING
SHOWING NEW PROPOSED BUILDING LAYOUT
326 BUTLERTOWN ROAD
MONTVILLE, CONNECTICUT
l�bul z;�t" ya�� SHEETS I OF I JOBS! 2005-004
•-DESCRIPTION
DATEVISIONSDATEJANUARY 19, 005 BY• E.R.M. S'(:A%�; I " = 20' FILE #PA05004
■
- �l