Loading...
HomeMy WebLinkAboutPlot Plan w SewerMANHOLE INSPECTION OPENING - MANHOLE INLET INLET BAFFLE 2/3 REQUIRED CAPACITY - OUTLET OUTLET DEVICE FILTER 1/3 REQUIRED CAPACITY 4 1lmtJ covin Vf% vcr in NOTE: CLEANOUT MANHOLES ARE ALL BAFFLED INSPECTION MANHOLES SHALL BE LOCATED AT A DEPTH NOT GREATER THAN 12" BELOW FINAL GRADE. APPENDIX B APPROVED SEP71C TANK OUTLET FILTERS WrL MAL OUTLET FILTERS }MANUFACTURER MODEL ORENCO SYSTEMS FT0444-36, FT0854-36, '44ORSBY do BOYNE FT1254-36, FT1554-36 TUF-TITE SANITEE UNITED CONCRETE CO. EF -4 ZABEL PL122 A100 A1800 A300 A1801 A100 -HIP A1800 -HIP A300 -HIP A1800 -HIP TYPICAL SEPTIC TANK NOT TO SCALE A LAYER OF NON -WOVEN FILTER FABRIC SHALL BE PLACED OVER ALL STONE BEFORE BACKFILLING. MINIMUM AVERAGE ROLL VALUES FOR FABRIC SHALL BE 1.5 OZ PER SQUARE YARD (PER ASTM D-3.776), A PERMITTIVITY OF 1.0 SEC (PER ASTM D-4491) AND A TRAPEZOID TEAR OF 15 LBS (PER ASTM D-4533) 48' APPROVED r 40PVC FILTER FABRIC J v MIN 6" COVER G 12 I" BROKEN -MIN 18' to MOTTLING STONE or GROUNDWATER TYPICAL SECTION LEACHING TRENCHES NOT TO SCALE PRECAST CONCRETE DISTRIBUTION BOX OR APPROVED EQUAL * 3" HIGHER THAN INV. IN 3" f* L PERFORATED DISTRIBUTION PIPE MODIFIED HIGH LEVEL OVERFLOW "D" BOX 2"x2"x48" WOOD POST 0 8' ON CENTER (MIN) 1 14 NOT TO SCALE INDUSTRIAL NETTING, SNOW FENCE OR WOVEN WIRE FENCE FOR SUPPORT FILTER FABRIC COMPACTED BACKFILL 1 FLOW 100' - IL-i.- iN 71 SEDIMENT FENCE NOT TO SCALE LEGEND ELEV 172.55 (NGVD) -.�----- 6" MIN. 8" - 3" e V6' LIQUID DEPTH APPROX 12-,T_ q BUILDING SETBACK LINE LENGTH NOT GREATER THAN - OUTLET OUTLET DEVICE FILTER 1/3 REQUIRED CAPACITY 4 1lmtJ covin Vf% vcr in NOTE: CLEANOUT MANHOLES ARE ALL BAFFLED INSPECTION MANHOLES SHALL BE LOCATED AT A DEPTH NOT GREATER THAN 12" BELOW FINAL GRADE. APPENDIX B APPROVED SEP71C TANK OUTLET FILTERS WrL MAL OUTLET FILTERS }MANUFACTURER MODEL ORENCO SYSTEMS FT0444-36, FT0854-36, '44ORSBY do BOYNE FT1254-36, FT1554-36 TUF-TITE SANITEE UNITED CONCRETE CO. EF -4 ZABEL PL122 A100 A1800 A300 A1801 A100 -HIP A1800 -HIP A300 -HIP A1800 -HIP TYPICAL SEPTIC TANK NOT TO SCALE A LAYER OF NON -WOVEN FILTER FABRIC SHALL BE PLACED OVER ALL STONE BEFORE BACKFILLING. MINIMUM AVERAGE ROLL VALUES FOR FABRIC SHALL BE 1.5 OZ PER SQUARE YARD (PER ASTM D-3.776), A PERMITTIVITY OF 1.0 SEC (PER ASTM D-4491) AND A TRAPEZOID TEAR OF 15 LBS (PER ASTM D-4533) 48' APPROVED r 40PVC FILTER FABRIC J v MIN 6" COVER G 12 I" BROKEN -MIN 18' to MOTTLING STONE or GROUNDWATER TYPICAL SECTION LEACHING TRENCHES NOT TO SCALE PRECAST CONCRETE DISTRIBUTION BOX OR APPROVED EQUAL * 3" HIGHER THAN INV. IN 3" f* L PERFORATED DISTRIBUTION PIPE MODIFIED HIGH LEVEL OVERFLOW "D" BOX 2"x2"x48" WOOD POST 0 8' ON CENTER (MIN) 1 14 NOT TO SCALE INDUSTRIAL NETTING, SNOW FENCE OR WOVEN WIRE FENCE FOR SUPPORT FILTER FABRIC COMPACTED BACKFILL 1 FLOW 100' - IL-i.- iN 71 SEDIMENT FENCE NOT TO SCALE LEGEND ELEV 172.55 (NGVD) -.�----- EXISTING CONTOUR DEEP TEST PROPOSED CONTOUR APPROX APPROXIMATE q BUILDING SETBACK LINE BSMT BASEMENT ELEV ELEVATION FND FOUNDATION INV INVERT M/L MORE OR LESS OC ON CENTER P-1 PERCOLATION TEST PVC POLY VINYL CHLORIDE T. P. TEST SIT TP4 u TP1 U1 82 1 SECTION "A"- "A" SCALE: HORIZ. 1"=30' VERT. 1"=3' cz I Lij_ti X `'' i a ? EXIST WELL ON ADJ PROPERTY l �s q- 140 Z Z 0 A w w a TO 91 EYE'=IGHT 3.5 OBIT HEIGHT 3.5' 7 HIL GAY L ROAD SITE LINE(NTS) 0 30 60 90 GRAPHIC SCALE IN FEET (CHECK BEFORE USING) EXIST WELL ON ADJ PROPERTY SANITARY DESIGN CRITERIA: A. PROPOSED TWO FAMILY HOME WITH FULL BASEMENT. NO TUBS OVER 100 GALLONS IN SIZE. NO GARBAGE DISPOSAL PLANNED. TOTAL BEDROOMS, 6. B. 2000 GALLON TWO COMPARTMENT SEPTIC TANK REQUIRED BY CODE AND PROVIDED. C. DESIGN PERCOLATION RATE: 1.0 TO 10.0 MIN/INCH D. MINIMUM LEACHING SYSTEM SPREAD HF = 20 GRADIENT = 4.1 TO 6.0%. RESTRICTION BETWEEN 48.1 TO 60" FF= 3.0, SIX BEDROOM HOME PF= 1.2, PERC RATE BETWEEN 5.1 & 10.0 MIN/INCH MLSS = HF X FF X PF 20 x 3 x 1.2 = 72' E. EFFECTIVE LEACHING AREA REQUIRED PER CODE: 990 SF F. 12" HIGH STONE LEACHING TRENCHES SELECTED FOR LEACHING SYSTEM DESIGN EFFECTIVE LEACHING ARE PROVIDED PER LF PER CODE: 3 SF MINIMUM LENGTH OF LEACHING TRENCH REQUIRED: 990 SF/3 SF/LF = 330- G. EFFECTIVE LEACHING AREA PROVIDED 4-90' LONG TRENCHES 4 x 90' x 3SF/LF = 1080 SF H. NOTE: RESERVE AREA LAYED OUT FOR 2 RUNS OF TEE -PEE GALLERIES 80' LONG AT 7.1 S PERCOLATION TEST. P-1 1.25 HR PRESOAK P-2 1.25 HR PRESOAK 22" DEEP 22" DEEP TIME READING TIME READING 10:50 16 3/4" 10:53 15" 11:00 19" 11:03 18" 11:10 20 3/4" 11:13 20" 11:20 22" 11:23 21 11211 11:30 23 1/4" 11:33 23" 11:40 24 1/2" 11:43 24 1/2" 11:50 25 3/4" 11:53 26" MIN PERC 8.00 MIN / INCH MIN PERC 6.70 MIN/INCH P-3 1.00 HR PRESOAK 26" DEEP TIME READING 2:20 14" 2: 30 17 1/4" 2:40 19 1/4" 2:50 20 1/211 3:00 21 3/4" 3:10 23" 3:20 24 1/4" MIN PERC 8.00 MIN / INCH coiCO I � "Opo IoM \J�,V,4SoA,p� / �. TP1 �A£ IP FEIN A WAIVER FOR PLAN CONFORMING TO A-2 STANDARDS IS REQUESTED CHAIRMAN DATE REVISION A - PLAN RE ISED TO INCORPORATE UNCAS HEALTH DISTRICT COMMENTS DATED 2/17/06 AND ANNING DIRECTOR COMMENTS DATED MARCH 9, 2006. GARY J. ALSKI coNN. .,9671 ELEV 172.55 (NGVD) < �d DEEP TEST PlT­--D-­TA---_ PIT ##1 0-10" TOPSOIL PIT #3 0-13" TOPSOIL 10-23" BROWN! SANDY LOAM 13 19" BROWN SANDY LOAM ` 23-68" GREY COMPACT SANDY TILL 19 66" GREY COMPACT SANDY TILL NO LEDGE NO LEDGE NO WATER NO WATER NO MOTTLING NO OTTLING NO RESTRICTIVE RES ICTIVE AT 29" PIT #2 0-8" TOPSOIL PIT 0-10" TOPSOIL 8-27" BROWN SANDY LOAM 10-2 BROWN SANDY LOAM 27-62" GREY COMPACT SANDY TILL 27-6 " GREY COMPACT SANDY TILL NO LEDGE NO LE E NO WATER NO WA R NO MOTTLING NO MOT LING RESTRICTIVE 29" RESTRIC VE AT 27" PIT 100 AND 101 `WITNESSED AND RECORDED BY DA. D CLAUGHLIN UNCAS HEALTH D8TRICT ON MARCH 17, 2006 PIT #101 0-8" 10PSOIL PIT #100 0-8" TOPSOIL 8-48" BROWN SA11DY LOAM 8-24" BROWN SANDY LOAM 48-96" GREY COMPACT SANDY TILL 24-82" GREY COMPACT SANDY TILL NO LEDGE NO LEDGE NO WATER NO WATER NO MOTTLING NO MOTTLING RESTRICTIVE AT PO" 4 RESTRICTIVE AT 52" SUBSTANCES. THE FILL MATERIALS SHALL MEET FILL REQUIREMENTS UNLESS OTHERWISE 'ONING COMPLIANCE TABLE R-20 ZONE REQUIRED PROVIDED MINIMUM LOT AREA. 20,000 SF 55,500 SIF MINIMUM LOT FRONTAGE 100' 150' MINIMUM FRONT `(ARD 40' 72' 40' ZD 15' MINIMUM SDE YARD MINIMUM REAR YARD 40' 245' PARKING SPACE 2 / UNIT 4 3. THE MATERIAL THAT PASSES THE #4 SIEVE IS THEN REWEIGHED AND THE MAXIMUM BUILDItOd HEIGHT 35' 32' SIEVE ANALYSIS STARTED. 30 I Lij_ti X `'' i a ? EXIST WELL ON ADJ PROPERTY l �s q- 140 Z Z 0 A w w a TO 91 EYE'=IGHT 3.5 OBIT HEIGHT 3.5' 7 HIL GAY L ROAD SITE LINE(NTS) 0 30 60 90 GRAPHIC SCALE IN FEET (CHECK BEFORE USING) EXIST WELL ON ADJ PROPERTY SANITARY DESIGN CRITERIA: A. PROPOSED TWO FAMILY HOME WITH FULL BASEMENT. NO TUBS OVER 100 GALLONS IN SIZE. NO GARBAGE DISPOSAL PLANNED. TOTAL BEDROOMS, 6. B. 2000 GALLON TWO COMPARTMENT SEPTIC TANK REQUIRED BY CODE AND PROVIDED. C. DESIGN PERCOLATION RATE: 1.0 TO 10.0 MIN/INCH D. MINIMUM LEACHING SYSTEM SPREAD HF = 20 GRADIENT = 4.1 TO 6.0%. RESTRICTION BETWEEN 48.1 TO 60" FF= 3.0, SIX BEDROOM HOME PF= 1.2, PERC RATE BETWEEN 5.1 & 10.0 MIN/INCH MLSS = HF X FF X PF 20 x 3 x 1.2 = 72' E. EFFECTIVE LEACHING AREA REQUIRED PER CODE: 990 SF F. 12" HIGH STONE LEACHING TRENCHES SELECTED FOR LEACHING SYSTEM DESIGN EFFECTIVE LEACHING ARE PROVIDED PER LF PER CODE: 3 SF MINIMUM LENGTH OF LEACHING TRENCH REQUIRED: 990 SF/3 SF/LF = 330- G. EFFECTIVE LEACHING AREA PROVIDED 4-90' LONG TRENCHES 4 x 90' x 3SF/LF = 1080 SF H. NOTE: RESERVE AREA LAYED OUT FOR 2 RUNS OF TEE -PEE GALLERIES 80' LONG AT 7.1 S PERCOLATION TEST. P-1 1.25 HR PRESOAK P-2 1.25 HR PRESOAK 22" DEEP 22" DEEP TIME READING TIME READING 10:50 16 3/4" 10:53 15" 11:00 19" 11:03 18" 11:10 20 3/4" 11:13 20" 11:20 22" 11:23 21 11211 11:30 23 1/4" 11:33 23" 11:40 24 1/2" 11:43 24 1/2" 11:50 25 3/4" 11:53 26" MIN PERC 8.00 MIN / INCH MIN PERC 6.70 MIN/INCH P-3 1.00 HR PRESOAK 26" DEEP TIME READING 2:20 14" 2: 30 17 1/4" 2:40 19 1/4" 2:50 20 1/211 3:00 21 3/4" 3:10 23" 3:20 24 1/4" MIN PERC 8.00 MIN / INCH coiCO I � "Opo IoM \J�,V,4SoA,p� / �. TP1 �A£ IP FEIN A WAIVER FOR PLAN CONFORMING TO A-2 STANDARDS IS REQUESTED CHAIRMAN DATE REVISION A - PLAN RE ISED TO INCORPORATE UNCAS HEALTH DISTRICT COMMENTS DATED 2/17/06 AND ANNING DIRECTOR COMMENTS DATED MARCH 9, 2006. GARY J. ALSKI coNN. .,9671 COMMERCIAL & RESIDEN LAND DEVELOPMENT CIVIL ENGINEERING ,,,��`�E'oF�,,,` , �� 1. BOUNDARY INFORMATION TAKEN FROM THE PROPERTY DEED AND FIELD SURVEY (VOL :�, ��•P • ••• c 'c�aY SITE PLANS 122, PG 935) SEPTIC DESIGNS _ • o 2. DEEP TEST PITS WERE WITNESSED AND RECORDED BY DAVID CLAUGHLIN, UNCAS HEALTH ' . SED 5k ., ENG10 9 HERITAGE DRIVE STONINGTON, CT. 06378 TEL. (860) 535-2283 F GENERAL NOTES 1. BOUNDARY INFORMATION TAKEN FROM THE PROPERTY DEED AND FIELD SURVEY (VOL 122, PG 935) 2. DEEP TEST PITS WERE WITNESSED AND RECORDED BY DAVID CLAUGHLIN, UNCAS HEALTH DISTRICT IN JANUARY AND MARCH 2006. 3. PERC TESTING WAS WITNESSED AND RECORDED BY GARY J. WINALSKI PE ON JANUARY 12 2006 AND MARCH 17 2006. 4. THIS LOT WAS TOPOED IN THE AREA OF THE HOUSE AND SEPTIC SYSTEM AND A BENCHMARK SET BY GARY J. WINALSKI, PE, ON FEBRUARY 4, 2006. 5. THIS LOT IS IN THE TOWN OF MONTVILLE R20 ZONE. TWO FAMILY HOMES PERMITTED BY SPECIAL PERMIT IN AN R20 ZONE. HOMES ARE I 6. SITE IS NOT LOCATED IN CAM ZONE. 7. SITE IS NOT LOCATED IN 100 YEAR FLOOD PLAN. 8. SELECT FILL PLACED WITHIN AND ADJACENT TO LEACHING AREA SHALL BE COMPRISED OF CLEAN SAND OR SAND AND GRAVEL. FREE FROM ORGANIC MATERIAL AND DELETERIOUS SUBSTANCES. THE FILL MATERIALS SHALL MEET FILL REQUIREMENTS UNLESS OTHERWISE APPROVED BY A PROFESSIONAL ENGINEER. FOR USE WITHIN THE LEACHING AREA. 1. THE FILL SHALL NOT CONTAIN ANY MATERIAL LARGER THAN THREE INCHES. 2. UP TO 45% OF THE DRY WEIGHT OF THE REPRESENTATIVE SAMPLE MAY BE RETAINED ON THE #4 SIEVE. THIS IS THE GRAVEL PORTION OF THE SAMPLE. 3. THE MATERIAL THAT PASSES THE #4 SIEVE IS THEN REWEIGHED AND THE SIEVE ANALYSIS STARTED. 4. THE REMAINING SAMPLE SHALL MEET THE FOLLOWING GRADUATION CRITERIA: SIEVE SIZE DRY SIEVE #4 100 100 #10 70-100 70-100 #40 10-50* 10-75* #100 0-20 0-5 #200 0-5 0-2.5+ , PERCENT PASSING THE #40 SIEVE CAN BE INCREASED TO NO GREATER THAN 75% IF THE PERCENT PASSING THE #100 SIEVE DOES NOT EXCEED 10% AND THE #200 SIEVE DOES NOT EXCEED 5%. THE LICENSED INSTALLER IS RESPONSIBLE FOR PREPARING THE LEACHING AREA WITH NECESSARY SELECT FILL. THE TOPSOIL IN THE LEACHING SYSTEM AREA MUST BE REMOVED AND THE SUBSOIL SACRIFICED PRIOR TO THE SELECT FILL PLACEMENT UNLESS. OTHERWISE DIRECTED BY THE DESIGN ENGINEER. THE INSTALLER SHALL TAKE NECESSARY STEPS TO PROTECT THE UNDERLYING NATURALLY OCCURRING SOIL FROM OVER COMPACTION OR DAMAGE. SELECT FILL SHALL EXTEND A MINIMUM OF FIVE (5) FEET LATERALLY IN ALL DIRECTIONS BEYOND THE OUTER PERIMETER OF THE LEACHING SYSTEM. THE COMMISSIONER OF PUBLIC HEALTH MUST APPROVE MANUFACTURED FILL. ROCK USED TO PRODUCED MANUFACTURED FILL MUST HAVE A LOSS OF ABRASION OF NOT MORE THAN 50% USING PASHTO METHOD T-96. SUPPLIERS OF MANUFACTURED FILL MUST MAKE APPLICATION TO THE COMMISSIONER OF PUBLIC HEALTH. DOCUMENTATION MUST BE SUBMITTED ON THE QUARRY OPERATION, AND PRODUCTION PROCESS. FILL SPECIFICATIONS (GRADUATION, PERMEABILITY, ETC.) AND A NARRATIVE OF THE QUALITY CONTROL /QUALITY ASSURANCE PROGRAM MUST ALSO BE INCLUDED. THE MANUFACTURED FILL PRODUCERS MUST BE PROVIDED ANNUAL PRODUCT REGISTRATIONS TO THE COMMISSIONER OF PUBLIC HEALTH. 9. AT THE TIME OF THIS DESIGN THERE WERE NO EXISTING WELLS WITHIN 75' OF THE PROPOSED SEPTIC SYSTEM AND THERE WERE NO EXISTING SEPTIC SYSTEMS WITHIN 75' OF THE PROPOSED WELL LOCATION. TO ENSURE BUILDING SETBACKS ARE MET AND MINIMUM HEALTH CODE REQUIREMENTS ARE MET. 10. THE FOUNDATION AND SEPTIC SYSTEM SHALL BE STAKED OUT AND GRADES BE ESTABLISHED BY A LICENSED LAND SURVEYOR. 11. THE PERFORATED PVC FOUNDATION DRAIN SHALL BE LOCATED A MINIMUM DISTANCE OF 25' FROM THE SEPTIC SYSTEM. THE FOUNDATION OUTLET DRAIN SHALL BE LOCATED NO CLOSER THAN 10' FROM THE SEPTIC AND SHALL MEET TABLE 2-C OF THE CODE. A RODENT PROOF COVER SHALL BE PROVIDED AT THE FOUNDATION OUTLET DRAIN AT "DAY LIGHT." 12 ELECTRIC, PHONE, AND CATV PROPOSED AS UNDERGROUND FROM UTILITY POLE, NO # 13. APPLICANT: STASH PROVITAS I. 34 LINCOLN AVE NORWICH, CT. 60560 (860) 213-1382 14. ENGINEER: GARY J. WINALSKI, PE 9 HERITAGE DRIVE STONINGTON, CT 06378 (860) 535-2283 15. OWNER: JOHN E STREET, JR 194 MERIDIAN GROTON, CT 06340 (860) 446-1835 16. THERE ARE NO WETLANDS ON THIS SITE AS DETERMINED BY MICHAEL SCHAEFER, CERTIFIED SOIL SCIENTIST IN FEBRUARY 2000.' 1 17. A WAIVER FOR PLAN CONFORMING TO A-2 STANDARDS IS REQUESTED. 18. THE PROPOSED WELL MUST BE TESTED FOR VOLATILE AND SEMI -VOLATILE ORGANICS PRIOR TO ISSUANCE OF A CERTIFICATE OF OCCUPANCY. _19. AFTER THE FILL IS PLACED AND COMPACTED, IT MUST BE PERC TESTED PRIOR TO 'I'NSALLATION OF THE SYSTEM. SANITAA �Y TION DATA. SANITARY INVERT AT FOUNDATION: 9 . 38'-4" DIAMETER SCHEDULE 40D1785 OR*QUAL PIPE (MIN SLOPE = IA" PER FT) �',,, 302000 GALLON TWO COMPARTMENT SEPTIC TANK -- INV. 90.25 IN INV. 90.00 OUT ®10'-4" DIA SDR 35 PVC PIPE 0 SPLITTER "D- BOX INV. IN 88.90 INV. OUT 88.70 Q ®® 10'-4" DIA SDR 35 PVC PIPE MODIFIED HIGH LEVEL OVERFLOW "D" BOX( INV. 88.70 IN INV. 88.50 OUT & OVERFLOW I f l�l ® "D" BOX , 4t i INV. 87.30 IN & OUT @3 90 LONG X 48 WIDE X 12 HIGH STONE LEACHING TRENCH BOTTOM OF TRENCH ELEVATION: 88.00 10 87.30 13 TRENCH INVERT: 88.50 12 87.80 TI A PROPOSED ENGINEERED SEPTIC SYSTEM DESIGN `"" PLOT PLAN FOR TWO FAMILY HOME 91 GAYH I LL ROAD SCALE = 1"=30' MONTVILLE, CONNECTIUCT FEBRUARY 2006