HomeMy WebLinkAboutSite PlanQ
w
N
T
r
co
0
0
cv
coo
0
0
c(S
Q_
U
Q.
cz
O
CC
+J
co
L_
0
U-
(0
L0
r
0
CO
H
w
J
0i
00
T_
0
0
_
M
`' )
X
"�^-..
\ -�--- WAY \` ___..._.-- ------
--------- -
r-
PROPOSED \ \
WELL (�R
� r
TH
_---- \ \
f f % � �\�C.� \ \ \
OTH
� \
// - -- #614 / ✓_ \ \
G! e
- -- TH
617
/ cy
tK
+- 6 �
/IX
1500 G
SEPTIC TANK
INV. IN \ /
-- - - - _ ,FOOTING DRAIN
/ OUTLET-
CLEAN OUT
OR -MANHOLE � -
_ iso
\ / _ilt- TH /
i
` r- - /,r J` .,.,, ate• � � ,/ / // � / � � � ' _ _ - i' --_-..__ ^_` /
15 2
TH �/ __�- _ 8' TYP. 2 PLACES
- -- � � '""' __,__ ---- -' � 4" INLET TYP3 PLACES
TH _ _ -' #6298. / TH �' . -
#62s�
-- TH
�#8296 \ . �r� RESERVE =-'
20' 0 20' 40'
FILTER FABRIC PRECAST CONCRETE 4'x8'x2'
SCALE: 1 "=20' F
Ing
- - - - - - PROPERTY LINE
SETBACK LINE
- - 544 - -- - EXIST. CONTOURS
EDGE OF ROAD
EDGE OF DRIVEWAY
® PRIMARY SEPTIC SYSTEM
L=
_J RESERVE SEPTIC SYSTEM
PROPOSED CONTOUR LINE
6" MIN.
COVER
24' ® -�
11 ' 4'
i
6'
LEACHING GALLERY
HS -20 LOADING
L
-I - INVERT
12*
1' DIAMETER
CRUSHED STONE
TYPICAL 240 LEACHING GALLERY TRENCH
N OT TO SCALE
OUTLET
4" L.P. P.V.C.
PIPE SEAL
�- 4" L.P. P.V.C. PIPE SEAL
TYP. 3 PLACES
PLAN VIEW
24"DIA. 24"DIA.
6», _ /-COVER COVER
118" 6»
20"
INLET
BAFFLE OUTLET
m 6" WALLS 49_1* „ 'FILTER
1 LIQUID DEVICE
6" _ LEVEL
CROSS SECTION VIEW
1,500 GALLON SEPTIC TANK
NOT TO SCALE
FILTER FABRIC
EXISTING DRIVEWAY
4" TOPSOIL
i o' MAx�rNUM
TEMPORARY VEGETATIVE COVER
.m
4" CLEAN FILL
LOAM & SEED CRO%"aS- SECTION DETAIL
NOT TO SCALE
mom P-,. -4
WIRE MESH
FENCING
A TEMPORARY SEEDING OF RYE GRASS WILL BE COMPLETED WITHIN 15 DAYS OF THE FORMATION
OF STOCKPILES, IF THE SOIL IN THE STOCKPILES HAS BEEN COMPACTED BY CONSTRUCTION
OPERATIONS IT SHALL BE LOOSENED TO A DEPTH OF 2 INCHES BEFORE THE FERTILIZER, LIME AND
SEED IS APPLIED. 10-10-10 FERTILIZER AT A RATE OF 7.5 POUNDS PER 1000 S.F.
LIMESTONE AT A RATE OF 90 LBS. PER 1000 S.F. SHALL BE USED. RYE GRASS APPLIED AT A
RATE OF 1 LB. PER 1000 S.F. SHALL PROVIDE THE TEMPORARY VEGETATIVE COVER. STRAW
FREE FROM WEEDS AND COARSE MATTER SHALL BE USED AT A RATE OF 70-90 LBS. PER 1000 S.F.
AS A TEMPORARY MULCH. APPLY MULCH AND DRIVE TRACKED EQUIPMENT UP AND DOWN SLOPE OVER
ENTIRE SURFACE SO CLEAT MARKS ARE PARALLEL TO THE CONTOURS.
PERMANENT VEGETATIVE COVER
TOPSOIL WILL BE REPLACED ONCE THE EXCAVATION HAS BEEN COMPLETED AND THE SLOPES ARE
GRADED TO A SLOPE NO GREATER THAN 2.5 TO 1. PROVIDE SLOPE PROTECTION ON ALL CUT SLOPES.
TOPSOIL WILL BE SPREAD AT A MINIMUM COMPACTED DEPTH OF 4 INCHES. ONCE THE TOPSOIL HAS
BEEN SPREAD, ALL STONES TWO INCHES OR LARGER IN ANY DIMENSION WILL BE REMOVED AS WELL AS
DEBRIS. APPLY AGRICULTURAL GROUND LIMESTONE AT THE RATE OF TWO TONS PER ACRE OR 100 LBS.
PER 1000 S.F. APPLY 10-10-10 FERTIUZER OR EQUIVALENT AT A RATE OF 300 LBS. PER ACRE OR
7.5 LBS. PER S.F. WORK LIMESTONE INTO THE SOIL TO A DEPTH OF 4 INCHES. INSPECT SEEDBED
BEFORE SEEDING. IF TRAFFIC HAS COMPACTED THE SOIL, RETILL COMPACTED AREAS. APPLY THE
FOLLOWING GRASS SEED MIX:
SEED MIXTURE Les ACRE LBS./ 1000 S.F.
KENTUCKY BLUEGRASS 20 0.45
CREEPING RED FESCUE 20 0.45
PERENNIAL RYEGRASS 5 0.10
45 1.00
THE RECOMMENDED SEEDING DATES ARE:
APRIL 1 - JUNE 15 AND AUGUST 1 - SEPTEMBER 15
FOLLOWING SEEDING, FIRM SEED BED WITH A ROLLER, MULCH WITH WEED FREE STRAW
IMMEDIATELY FOLLOWING SEEDING. IF A PERMANENT VEGETATIVE STAND CANNOT BE ESTABLISHEC
SELECT FILL SPECIFICATION
SELEG. FILL PLACED WITHIN AND ADJACENT TO LEACHING SYSTEM AREAS SHALL
BE COMPRISED OF CLEAN SAND, OR SAND AND GRAVEL, FREE FROM ORGANIC
MATTER AND FOREIGN SUBSTANCES. THE SELECT FILL SHALL MEET THE
FOLLOWING REQUIREMENTS PER THE CONNECTICUT PUBLIC HEALTH CODE FOR
USE WITHIN THE LEACHING AREA:
1. THE SELECT FILL SHALL NOT CONTAIN ANY MATERIAL LARGER THAN THE
THREE (3) INCH SLEEVE.
2. UP TO 45% OF THE DRY WEIGHT OF THE REPRESENTATIVE SAMPLE MAY BE
RETAINED ON THE #4 SLEEVE (THIS IS THE GRAVEL PORTION OF THE SAMPLE),
3. THE MATERIAL THAT PASSES THE #4 SIEVE IS THEN REWEIGHED AND THE
SIEVE ANALYSIS STARTED,
4. THE REMAINING SAMPLE SHALL MEET THE FOLLOWIG CRITERIA:
PERCENT PASSING
SIEVE SIZE WET SIEVE DRY SIEVE
#4 100 100
#10 70-100 70-100
#40 10-50* 10-75
#100 0-20 0-5
#200 0-5 0-2.5
* PERCENT PASSING THE #40 SIEVE CAN BE INCREASED TO NO GREATER THAN
75% IF THE PERCENT PASSING THE #100 SIEVE DOES NOT EXCEED 10% AND
THE #200 SIEVE DOES NOT EXCEED 5%.
GENERAL NOTES
1. TOPOGRAPHIC INFORMATION ON THIS PLAN COMPLIES WITH T-2 MAPPING
STANDARDS.
2, BASE FOR LEVELS: SUBDIVISION MAP.
3. PROPOSED HOUSE AND SEPTIC SYSTEM TO BE STAKED IN THE FIELD BY
A LAND SURVEYOR LICENSED IN THE STATE OF CONNECTICUT.
4. LOT AREA - 17.86± ACRES
5. ALL WORK AND MATERIAL (SEPTIC TANK, DISTRIBUTION BOX, PIPE)
SHALL CONFORM TO THE CONNECTICUT PUBLIC HEALTH CODE
REGULATIONS AND STANDARDS FOR SUBSURFACE SEWAGE DISPOSAL
SYSTEM.
6. SEWER LINE FROM FOUNDATION WALL TO SEPTIC SHALL BE 4"
SCHEDULE 40 PVC - ASTM D 1785 AND JOINTS PER HEALTH DEPT. CODE,
7. TRENCHES SHALL BE SET LEVEL FOR ENTIRE LENGTH AND HAVE A
CENTER TO CENTER SPACING OF 9 FEET.
8. PIPE FROM SEPTIC TANK TO DISTRIBUTION LINES SHALL BE 4" SOLID
PVC CONFORMING TO ASTMD-3034 AND SDR -35.
9. FOUNDATION DRAIN PIPE FROM HOUSE TO OUTLET SHALL CONFORM
TO TABLE 2-C OF THE CONNECTICUT PUBLIC HEALTH CODE REGULATIONS
AND STANDARDS FOR INSTALLATION WITHIN 25 FEET OF A SEWAGE DISPOSAL
SYSTEM.
10. THERE ARE PRESENTLY NO KNOWN WATER WELLS WITHIN 75' OF THE
PROPOSED SEPTIC SYSTEM.
11, A VERTICAL BENCHMARK WILL BE PROVIDED WITHIN 100 FEET OF THE
PROPOSED HOUSE LOCATION PRIOR TO THE START OF CONSTRUCTION.
12. CLEAR AND GRUB THE AREA WHERE THE SEPTIC SYSTEM AND HOUSE ARE
TO BE CONSTRUCTED. ALL TOPSOIL IS TO BE STRIPPED AND STOCKPILED
FOR FUTURE USE.
13. ALL FILL MATERIAL SHALL BE CLEAN EARTH FREE OF STUMPS, ORGANICS,
CONSTRUCTION DEBRIS AND TOPSOIL.
14. TOPSOIL SHALL BE RE-APPUED OVER ALL FILL AREAS AND ALL DISTURBED
AREAS TO PROVIDE A MINIMUN DEPTH OF FOUR INCHES.
15. ALL EXISTING UTILITIES TO BE ACCURATELY LOCATED PRIOR TO CONSTRUCTION.
CALL BEFORE YOU DIG: 1-800-922-4455.
16. IF BLASTING IS REQUIRED A PRE -BLAST SURVEY WILL BE REQUIRED.
MAP REFERENCE
SUBDIVISION PLAN, ALLISON'S WAY SUBDIVISION, PREPARED FOR RTT
DEVELOPMENT, INC., CHAPEL HILL ROAD & FORSYTH ROAD,
MONTVILLE, CT, PREPARED BY CME/CPK DESIGN GROUP, 110
BROADWAY, NORWICH, CT, DATED: 1/01/03, REVISED TO: 6/20/2003.
DESIGN DATA
PERCOLATION RATE = 10.4 MIN./INCH
5 BEDROOM RESIDENCE REQUIRES 1050 SF OF LEACHING AREA
PROVIDE 2 82' ROWS 24" GALLERIES 0 15' o/c
EFFECTIVE LEACHING AREA = 164 LF X 6.8 SF/LF = 1115.2 SF
PROVIDE 1,500 GAL. 2 -COMPARTMENT TANK
AS FOLLOWS
1. REMOVE AND STOCKPILE TOPSOIL.
2, PLACE BANK RUN GRAVEL (LESS THAN 5% FINES) PLACED IN
6" LIFTS AND COMPACTED TO 957. DENSITY.
3. EXCAVATE 4' WIDE TRENCHES AND PREPARE SURFACE.
4. FILL TRENCHES WITH 1" WASHED STONE TO HEIGHT OF PIPE INVERTS
PLACE PIPE IN TRENCH, AND FILL TO 2" OVER TOP OF PIPE.
5, CAP ENDS OF PIPES,
6. PLACE A 4' WIDE STRIP OF NON -WOVEN FILTER FABRIC ON TOP OF'
THE ENTIRE LENGTH OF THE SYSTEM AND BACKFILL WITH NATIVE MATERIAL.
7, REPLACE TOPSOIL, SEED do MULCH.
FILTER BARRIER INSTALLATION & MAINTENANCE
1. DIG A fi' TRENCH ON THE UPHILL SIDE OF THE BARRIER LOCATION.
2. POSITION THE POSTS ON THE DOWNHILL SIDE OF THE BARRIER AND DRIVE THE
POST 1.5 FEET INTO THE GROUND.
3. LAY THE BOTTOM 6" OF THE FABRIC IN THE TRENCH TO PREVENT UNDERMINING
AND BACKFILL.
4. INSPECT AND REPAIR BARRIER AFTER HEAVY RAINFALL.
5. SEDIMENT DEPOSITS ARE TO BE REMOVED WHEN THEY REACH A HEIGHT OF ONE
FOOT BEHIND THE BARRIER AND ARE TO BE DEPOSITED IN AN AREA WHICH IS
NOT REGULATED BY THE INLAND WETLANDS COMMISSION.
6. INSPECTIONS AND NECESSARY REPAIRS WILL BE MADE TWICE WEEKLY.
PERCOLATION
RATE
INFORMATION PROVIDED
PER REFERENCE PLAN
PERCOLATION RATE: LOT
#43/9-016 = 10.4 MIN/INCH
TEST HOLE DATA
RECORDED BY: UNCAS HEALTH DISTRICT DATE:
1/7/03,
1/7/9/03, 5/9/03
TH#614
LEDGE 0 24"
IH#6286
0-1 " TOPSOIL
TH#628B
0-3" TOPSOIL
1"-28" BROWN SANDY LOAM
3"-28" BROWN SANDY LOAM
28"-87" TAN SILTY SAND W/ROCKS
28"-79" SAND AND GRAVEL W/STONE
TH1615
NO LEDGE
NO LEDGE
NO WATER
NO WATER
LEDGE A 32"
NO MOTTLING
TH#629A
NO MOTTLING
TH161s
0-1" TOPSOIL
TH#629
0-2" TOPSOIL
LEDGE 0 17"
1"-31 BROWN SANDY LOAM
2"-21" BROWN SANDY LOAM
31"-92" GREY SILTY SAND W/ROCKS
21"-77" SAND AND GRAVEL W/STONE
TH161
NO 'LEDGE
NO LEDGE
NO 'WATER
NO WATER
LEDGE 0 12"
NO MOTTUNG
NO MOTTLING
CLA Engineers, Inc.
CIVIL - STRUCTURAL - SURVEYING
I 317 Main Street Norwich, CT 06360
No. DATE REVISION (860) 886-1966 Fax (860) 886-9165
Project No.
RTT Development, Inc. CIA -3186
Proj. Engineer
ALLISON'S WAY SUBDIVISION J.F.M.
#156 FORSYTH ROAD Date:
1/03/06
MONTVILLE, CT Sheet N®.
Septic Design - Lot #43/9-016