HomeMy WebLinkAboutLocation & Topo Surveyw
Z
N
N
ti
S�� X01
T
BENCH ]SANK EDGE OF \ \ \
MAG NAIL SET PAVEMENT \
ELEV 96.24 _
(ASSUMED DATUM) -� (GVF� \ \ / 12" GATE
BOTTOM OF UPPER D -BOX "POK0 \, POSTS
LEACHING TRENCHES INV 96.27 IN \ \, \ METS
ELEV 96.75
N/F ` / !NV 96.1 D OUT - \ \ SW"
AUSTIN & SONS INC. s
/ GATE
VOLUME 141 PAGE z5 / OVERFLOW D -BOX BOTTOM OF LOWER \
INV 97.25 IN LEACHING TRENCH \
INV 97.42 OUT ELEV 95.60 \
�87' 1746 "E \ - --- \
If
N/F
KRAVITZ EQUITY ASSOCIATION
VOLUME 294 PAGE 54
DEEP TEST PI?J RES'UL�S
I �.��urtDttrirs
T t r
m�
. . .
LAND SURVEYING N HISTORICAL LAND RECORD RESEARCH
COMMERCIAL & RESIDENTIAL DEVELOPMENT
P. 0. BOX 184
179 PACHAUG RIVER DRIVE
GRISWOLD CONNECTICUT 06351
TELEPHONE (860) 376-2006
FAX (860) 376-5899
1
SANIrARY CR£rERIA
PROPOSED 2 -FAMILY HOUSE (4 BEDROOMS - 2/UNIT)
DESIGN PERCOLATION RATE = 5.1-10.0 MINUTES/INCH
LEACHING AREA REQUIRED = 660 SF EFFECTIVE
DESIGN: 1,500 -GALLON SEPTIC TANK AND 3 ROWS OF 75' OF 4' WIDE, 12'
HIGH LEACHING TRENCHES, 1ST 2 ROWS ON SAME LEVEL WITH ENDS
CONNECTED AND 3R0 TRENCH BY SERIAL DISTRIBUTION.
LEACHING AREA PROVIDED: 3 x 75' x 3.0 SF/LF = 675 SF EFFECTIVE
100% RESERVE AREA PROVIDED
.9WI.NIjw'U M L EAC3-fINC�
SYS�rEM SPREAD CALC'i.LLA�rION
HYDRAULIC GRADIENT = 6.7%
DEPTH TO RESTRICTIVE LAYER 33"
HYDRAULIC FACTOR = 26
FLOW FACTOR FOR 4 BEDROOMS = 2.0
PERCOLATION FACTOR FOR 5.1- 10.0 MINUTES/INCH = 1.2
MLSS REQUIRED = 62.4'
MLSS PROVIDED = 75'
7.s. 65 -
SITE DATA TABLE
ZONE: R--40
ITEM
DEEP TEST PITS WERE WITNESSED BY DAVID COUGHLIN OF THE UNCAS HEALTH DISTRICT
PROVIDED
LOT AREA
40,000 S.F.
69,345f SF.
AND JOHN f-AULISE, L.S. OF BOUNOARIES LLC ON 10-8-04..
PERCOLATION TEST WAS
158.20 RT
FRONT YARD
50 FT
51.3± IrI'
PERFORMED EY BOUNDARIES LLC.
15 FT
242± FT
REAR YARD
50 FT
55.9± F'I'
TEST PIT J5
35 FT
25t FT
PARKING SPACES
4
8
ON- 6m, TOPSOIL
WELL
SANITARY SYSTEM
ON-SITE
SEPTIC SYSTEM
6"- 40" TAN MEDIUM SANDY LOAM
40"- 96" MEDIUM COARSE SAND AND GRAVEL
P-2
DEPTH = 28.5"
MOTTLING ® 41 " NO GROUNDWATER, NO LEDGE
PRESOAK AT 1:10
TIMEEADING
L BCS. EA D & AB B RE�VI.�l.TT O S
TEST PIT #6
ON- 3" TOPSOIL
136 R
2"
1:41 17 11
3"- 37" TAN MEDIUM SANDY LOAM
1:46 21 1/4"
37"- 93" MEDIUM COARSE SAND AND GRAVEL
1:51 24"
REBAR OR DRILL TO BE SET
FT
FEET
MOTTLING 0 37; NO GROUNDWATER, NO LEDGE '
1:56 25 3/4"
SNET
SOUTHERN NEW ENGLAND TELEPHONE
W/
WITH
TEST PIT #i
2:01 27"
IP
IRON PIPE
DH
DRILL HOLE
O"- 4" TOPSOIL
2:06 DRY
4w- 41 " TAN MEDIUM SANDY LOAM
P-2 PERCOLATION RATE
f
MORE OR LESS
`�
UTILITY POLE
41 " 81 " MEDIUM COARSE SAND AND GRAVEL
® 28.5" DEPTH = 3.3 MINUTES/INCH
CHD
CONNECTICUT HIGHWAY DEPARTMENT
MOTTLING 0 41"N' NO GROUNDWATER, NO LEDGE
o
STONE WALL
REC.
RECOVERED
TEST PIT #3MON
MONUMENT
O"- 6" TOPSOIL
TP TEST PIT
®
WELL
6m- 33" TAN SILTY LOAM
33" 81" GREY SILTY SAND AND GRAVEL
—
BUILDING SETBACK LINE
MOTTLING @ 33', NO GROUNDWATER, NO LEDGE
PERCOLATION TEST LOCATION
I �.��urtDttrirs
T t r
m�
. . .
LAND SURVEYING N HISTORICAL LAND RECORD RESEARCH
COMMERCIAL & RESIDENTIAL DEVELOPMENT
P. 0. BOX 184
179 PACHAUG RIVER DRIVE
GRISWOLD CONNECTICUT 06351
TELEPHONE (860) 376-2006
FAX (860) 376-5899
1
SANIrARY CR£rERIA
PROPOSED 2 -FAMILY HOUSE (4 BEDROOMS - 2/UNIT)
DESIGN PERCOLATION RATE = 5.1-10.0 MINUTES/INCH
LEACHING AREA REQUIRED = 660 SF EFFECTIVE
DESIGN: 1,500 -GALLON SEPTIC TANK AND 3 ROWS OF 75' OF 4' WIDE, 12'
HIGH LEACHING TRENCHES, 1ST 2 ROWS ON SAME LEVEL WITH ENDS
CONNECTED AND 3R0 TRENCH BY SERIAL DISTRIBUTION.
LEACHING AREA PROVIDED: 3 x 75' x 3.0 SF/LF = 675 SF EFFECTIVE
100% RESERVE AREA PROVIDED
.9WI.NIjw'U M L EAC3-fINC�
SYS�rEM SPREAD CALC'i.LLA�rION
HYDRAULIC GRADIENT = 6.7%
DEPTH TO RESTRICTIVE LAYER 33"
HYDRAULIC FACTOR = 26
FLOW FACTOR FOR 4 BEDROOMS = 2.0
PERCOLATION FACTOR FOR 5.1- 10.0 MINUTES/INCH = 1.2
MLSS REQUIRED = 62.4'
MLSS PROVIDED = 75'
7.s. 65 -
SITE DATA TABLE
ZONE: R--40
ITEM
MQUUMD
PROVIDED
LOT AREA
40,000 S.F.
69,345f SF.
LOT FRONTAGE
150 FT
158.20 RT
FRONT YARD
50 FT
51.3± IrI'
SIDE YARD
15 FT
242± FT
REAR YARD
50 FT
55.9± F'I'
BUILDING HEIGHT
35 FT
25t FT
PARKING SPACES
4
8
WATER SUPPLY
WELL
SANITARY SYSTEM
ON-SITE
SEPTIC SYSTEM
ems_ LOCATION MAP
SCALE: I"=1000'
sURTE y Wo�rEs
EDGE OF 1. THIS SURVEY AND MAP HAS BEEN PREPARED IN ACCORDANCE WITH
PAVEMENT SECTIONS 20-30OB-1 THROUGH 2O-30OB-20 OF THE REGULATIONS OF
CONNECTICUT STATE AGENCIES AND "STANDARDS FOR SURVEYS AND MAPS
IN THE STATE OF CONNECTICUT" AS ADOPTED FOR USE BY THE
CONNECTICUT ASSOCIATION OF LAND SURVEYORS, INC. ON SEPTEMBER 260
1996. IT IS AN IMPROVEMENT LOCATION AND TOPOGRAPHIC SURVEY BASED
ON DEPENDENT RESURVEY AND CONFORMS TO HORIZONTAL CLASS A-2 AND
TOPOGRAPHIC CLASS T-2 ACCURACY STANDARDS. IT IS INTENDED TO BE
USED FOR SITE DEVELOPMENT.
2. NORTH ORIENTATION DEPICTED HEREON IS BASED ON A MAGNETIC BEARING
TAKEN ON NOVEMBER 29, 2004.
1
�. 3. CONTOURS DEPICTED HEREON WERE DERIVED FROM ACTUAL FIELD SURVEY
AND ARE BASED ON ASSUMED DATUM.
4. REFERENCE MAPS:
O
A. "PROPERTY OF MOHEGAN REALTY CO. INC., MONTVILLE, CONN., SCALE:
1 -100, MAY 7, 1960,- PREPARED BY THOMAS M. PETERSON.
o B. "MAP SHOWING LAND OF CALVIN H. JR. & PHILLIS R. HEATH, 16 FIELDING
DRIVE, UNCASVILLE, CONNECTICUT, SCALE: 1"-40', OCT 2, 1972, PLAN
225-72,1" PREPARED BY RAMON S. MAGSUMBOL.
C. "CONNECTICUT STATE HIGHWAY DEPARTMENT RIGHT OF WAY MAP, TOWN OF
/ MONTVILLE, CONNECTICUT TURNPIKE, I-•r,uM HAMOND HILL ROAD NORTHERLY TO
THE MONTVILLE-NORWICH TOWN LINE, SCALE: 17-80', DATE: DECEMBER 27,
�► 1962, REVISED TO: APRIL 29, 1965, NUMBER: 85-06, SHEET NO. 1,
?S, SECTION 2. "
D. "CONNECTICUT STATE HIGHWAY DEPARTMENT RIGHT OF WAY MAP, TOWN OF
MONTVILLE, CONNECTICUT TURNPIKE, FROM RAMOND HILL ROAD NORTHERLY TO
THE MONTVILLE-NORWICH TOWN LINE, SCALE: 1`80', DATE: OCTOBER 25,
1962, NUMBER: 85-06, SHEET NO. 6 OF 6, SECTION 1."
E. "TOWN OF MONTVILLE MAP SHOWING LAND & RIGHTS OF ACCESS ACQUIRED
FROM MOHEGAN REALTY CO., INC., BY THE STATE OF CONNECTICUT
TURNPIKE, SCALE: 1N-40", PUB. ACT 52, SPEC. SESSION JUNE 1955, JULY
1960,'* PREPARED BY STANLEY L. ALLEN.
F. "PLAN MADE FOR MOHEGAN REALTY CO. INC. IN THE TOWN OF MONTVILLE,
SCALE: 17-100', DEC. 1956," PREPARED BY F. E. ROBINSON.
G. "TOWN OF MONTVILLE MAP SHOWNING LAND & RIGHTS OF ACCESS ACQUIRED
FROM COUNTY OF NEW LONDON BY THE STATE OF CONNECTICUT,
GREENWICH-KILLINGLY EXPRESSWAY, SCALE: 17-40', 1953 SUPP. CHAP. 107,
PART IV, MARCH 1955, SHEETS 1 & 2 OF 2. "
APPROVED BY THE TOWN OF MONTVILLE PLANNING
AND ZONING COMMISSION
CHAIRMAN/SECERETARY DATE
EROSION CONTROL PLAN CERTIFIED BY THE PLANNING
AND ZONING COMMISSION
CHAIRMAN/SECERETARY
.L14PR011E�A4ENT fOC._q.���.__�_
—AND—
T'07'OC3 R.,APHIC SURATEY
PREPARED FOR
"TO MY KNOWLEDGE AND BELIEF THIS MAP IS SUBSTANTIALLY3TAT-Cif Cows7_R*uC7l_ojv
GRAPHIC SCALE CORRECT AS NOTED HER ."
,o o ,o ,o w 8088 FIELDING DRIVE
411' CONNECTICUT
(
IN FEET) � 70016 4 3 ob SCALE: 1 "=20' FEBRUARY 2006 JOB I.D. NO. 04-1066 SHEET 1 OF 2
1 inch = 20 ft. 01-� �v' F,AvUS JR. L.S. LICENSE N0. DATE REVISION 1 PER UDH COMMENTS 3-14-06
REVISION 2 PER STAFF COMMENTS 3-24-06
FILTER FENCE
a-�P
COMPACTED
BACKFILL
EXCAVATE - -'
6"x 6" TRENCH
FLOW
EXISTING GRADE
12" MIN.
DEPTH UNDISTURBED
GROUND
SEDI�AIEW9 _/ FENCE DETAIL
NOT TO SCALE
10' TO TOP
OF EMBANKMEN
2" MIN.
4" PERF. FM
9' ON CENTER
PROPOSED GRADE,
GRADE TO PREVENT
PONDING
NON -WOVEN
FABRIC FILTER
I" SIZE BROKEN STONE
18" MIN. TO GROUNDWATER/MOTTLING
48" MIN. TO LEDGE/ROCK
12"x 48" S�ON�' lE.AC3fING
NOT TO SCALE
qEWERA-L W07 -'ES
I. THIS SEPTIC SYSTEM INSTALLATION INCLUDING ALL MATERIALS (PIPING, SEPTIC TANK, STONE, FILL, ETC.) USED
FOR THIS SEPTIC SYSTEM SHALL CONFORM TO THE CURRENT EDITION/REVISION OF THE 'TECHNICAL STANDARDS
FOR SUBSURFACE SEWAGE DISPOSAL SYSTEMS" REVISED JANUARY 1, 2004 OF THE CONNECTICUT PUBLIC HEALTH
CODE BY THE STATE OF CONNECTICUT DEPARTMENT OF PUBLIC HEALTH.
2. THE PROPOSED HOUSE SEWER FROM THE BUILDING TO THE SEPTIC TANK SHALL BE SCHEDULE 40 PVC ASTM D
1785/ASTM D 2665 OR APPROVED EQUAL AND INDICATED 1N TABLE NO. 2 OF 'TECHNICAL STANDARDS FOR
SUBSURFACE SEWAGE DISPOSAL SYSTEMS". ALL OTHER SEWER PIPE FOR THIS SEPTIC SYSTEM SHALL BE 4" PVC
ASTM D3034, SDR 35 WITH RUBBER COMPRESSION GASKET OR BELL AND SPIGOT OR APPROVED EQUAL.
3. THERE ARE NO WELLS (POTABLE, GEOTHERMAL, OR IRRIGATION) WITHIN 75' OF THE PROPOSED SEPTIC SYSTEM.
4. THERE SHALL BE NO STUMPS OR BOULDERS BURIED WITHIN 50' DOWN GRADIENT OF THE SEPTIC SYSTEM.
SHOULD ANY SIGNIFICANT VARIATIONS FROM THE TEST HOLE DATA BE ENCOUNTERED DURING EXCAVATIONS (LEDGE,
GROUNDWATER, MOTTLING, SOIL TYPE, ETC.), THE DESIGN ENGINEER SHALL BE NOTIFIED PRIOR TO INSTALLATION OF
THE SEPTIC SYSTEM.
5. ALL EXISTING UTILITIES ARE APPROXIMATE ONLY. THE CONTRACTOR SHALL VERIFY ALL UTILITY LOCATIONS AND
ELEVATIONS PRIOR TO ANY CONSTRUCTION. CONTRACTOR SHALL CONTACT "CALL -BEFORE -YOU -DIG" AT
1-800-922-4455 AT LEAST 48 HOURS PRIOR TO ANY EXCAVATION.
6. THE PROPOSED FILL FOR THIS SEPTIC SYSTEM SHALL MEET THE FOLLOWING SPECIFICATIONS.
A. 10090 OF FILL SHALL PASS THROUGH A 3" SIEVE.
B. MAXIMUM % OF GRAVEL (BETWEEN 14 & 3" SIEVE) = 4590.
C. GRADATION OF FILL WITHOUT THE GRAVEL SHALL MEET THE FOLLOWING CRITERIA:
SIEVE SIZE % PASSING (WET) 90 PASSING (DRY)
#4 100% 1DO%
/10 70 - 10090 70 - 100%
#40 10 - 50%* 10 - 759
# 100 0 - 20.E 0 - 590
#200 0-590 0-2.5%
D. * PERCENT PASSING THE 140 WET SIEVE CAN BE INCREASED TO NO GREATER THAN 7590 IF THE PERCENT
PASSING THE #100 SIEVE DOES NOT EXCEED 10% AND THE 1200 SIEVE DOES NOT EXCEED 5%.
E PERCOLATION RATE AFTER PLACEMENT AND COMPACTION SHALL BE FASTER THAN OR EQUAL TO 10.0
MINUTES/INCH.
A WET OR DRY SIEVE ANALYSIS MAY BE REQUIRED PRIOR TO FILL PLACEMENT TO VERIFY THAT IT MEETS THESE
SPECIFICATIONS. THE FILL SHALL BE APPROVED BY THE UNCAS HEALTH DISTRICT OR DESIGN ENGINEER PRIOR TO
ITS PLACEMENT ON SITE.
X,ARP*,,AJTVE
THIS PROPOSAL INVOLVES THE CONSTRUC77ON OF A TWO FAMILY DWELLING ON AN EXISTING 1.59 ACRE LOT OF RECORD. THE
PROPERTY IS LOCATED IN AN R-40 ZONE AT THE END OF FIELDING DRIVE.
THE RESIDENTIAL DWELLING WILL HAVE AN ON-SITE SEPTIC SYSTEM AND A WELL.
EROSION CONTROL MEASURES WILL BE IMPLEMENTED DURING CONSTRUCTION INCLUDING ANTI -TRACKING PAD AT THE; ROAD
ENTRANCE LOCATIONS AND SEDIMENT FENCE AT LOCATIONS DOWN GRADIENT OF EARTHWORK OPERATIONS.
EROSr9&! CONTROL MEASURES WILL BE MAINTAINED THROUGHOUT THE PROJECT CONSTRUCTION. AFTER CONSTRUCTION/ REGRADING IS
COMPLETED, ALL DISTURBED AREAS SHALL. .BE LOAMED (4" MINIMUM) .AND SEEDED WITH -BASS FOR PERMANENT STABILIZATION.
EROSION CONTROL MEASURES WILL BE REMOVED ONL'r AFTER ALL L115 JRBED ARES KAVF BEE.,'V PERPIANENTLY STAE UZED
tt rt r s
L*L*Co
LAND SURVEYING N HISTORICAL LAND RECORD RESEARCH
COMMERCIAL & RESIDENTIAL DEVELOPMENT
P.O. BOX 184
179 PACHAUG RIVER DRIVE
G'RISWOLD, CONNECTICUT 06351
TELEPHONE (860) 376-2006
FAX (866) 376-5899
APPROVED BY THE TOWN OF MON_TVILLE PLANNING
AND ZONING COMMISSION
CHAIRMAN/SECERETARY
DATE
EROSION CONTROL PLAN CERTIFIED BY THE PLANNING
AND ZONING COMMISSION
CHAI RMAN/SECERETARY
DATE
7. APPROVED AGGREGATE SHALL BE STONE AGGREGATE OR OTHER PRODUCTS APPROVED BY THE COMMISSIONER
OF PUBLIC HEALTH. STONE AGGREGATE SHALL BE BROKEN STONE, CRUSHED STONE, OR SCREENED GRAVEL
MEETING THE CONNECTICUT DEPARTMENT OF TRANSPORTATION FORM 816 (OR LATEST REVISION THERETO)
SPECIFICATION M.01.01 FOR NO. 4 STONE, FREE OF SILT, DIRT, OR DEBRIS, SHALL SHOW A LOSS OF ABRASION
OF NOT MORE THAN 50X USING AASHTO METHOD T-96 AND CONFORM TO THE FOLLOWING:
SIEVE SIZE 90 PASSING
2 INCH 10090
1.5 INCH 90 - 100%
1 INCH 20 - 5590
3/4 INCH 0 - 10.E
3/8 INCH 0 - 59
8. NO DEVIATION FROM THE APPROVED DESIGN PLAN SHALL BE ALLOWED WITHOUT PRIOR APPROVAL FROM THE
UNCAS HEALTH DISTRICT AND THE DESIGN ENGINEER.
9. THE SEPTIC TANK SHALL BE PRECAST CONCRETE UNLESS OTHERWISE AUTHORIZED BY THE DESIGN ENGINEER.
10. SITE PREPARATION PROCEDURE FOR THE INSTALLATION OF THE PROPOSED SEPTIC SYSTEM:
A. STRIP ALL TOPSOIL, VEGETATION AND ORGANIC MATERIAL IN THE AREA OF AND 5' SURROUNDING THE
PRIMARY LEACHING TRENCHES.
B. USING A HEAVY RAKE OR EQUAL, THOROUGHLY SCARIFY AND ROUGHEN UP THE EXPOSED SUBSOIL.
PREVENT ANY VEHICULAR TRAFFIC, BACKHOE, TRUCKS, ETC. FROM SMOOTHING/COMPACTING THIS EXPOSED
SUBSOIL.
C. PLACE AND COMPACT SELECT FILL MATERIAL MEETING SPECIFICATIONS INDICATED ABOVE (NOTE 16) IN LIFTS
OF NOT GREATER THAN 12" IN THE AREA OF THE PROPOSED LEACHING TRENCHES UP TO AT LEAST THE
ELEVATION OF THE TOP OF THE LEACHING TRENCHES.
D. PERFORM AT LEAST 1 PERCOLATION TEST ON PLACED FILL. FILL MUST HAVE A PERCOLATION RATE EQUAL
TO OR FASTER THAN THAT AS INDICATED IN NOTE #6.D. IF PERCOLATION RATE IS SLOWER THAN THAT RATE, ALL
FILL SHALL BE REMOVED AND REPLACED WITH ACCEPTABLE FILL MEETING PROPER SPECIFICATIONS.
E. INSTALL SEPTIC SYSTEM PER PLAN USING APPROVED AGGREGATE AS INDICATED IN NOTE 17.
F. COVER SYSTEM WITH A MINIMUM OF 6" OF LOAM IN LAWN AREAS, GRADE TO PREVENT PONDING AND SEED
WITH GRASS TO STABILIZE. THE FINISHED GRADE 10' FROM ANY PART OF THE PROPOSED LEACHING TRENCHES
SHALL BE AT LEAST THE SAME ELEVATION AS THE TOP OF THE RESPECTIVE LEACHING TRENCH.
G. CLEANOUT MANHOLES AT THE INLET BAFFLE AND AT THE OUTLET FILTER OF THE SEPTIC TANK OR
ASSOCIATED RISERS AT THESE LOCATIONS IF REQUIRED SHALL BE LOCATED AT A DEPTH NOT GREATER THAN 12"
BELOW FINAL GRADE.
11. FOR EXACT HOUSE DIMENSIONS, SEE BUILDING PLANS.
12. PRIOR TO THE START OF CONSTRUCTION, THE HOUSE AND SEPTIC SYSTEM SHALL BE STAKED OUT BY A LICENSED
LAND SURVEYOR.
XOTE'S AWD DE7.AILS
PREPARED FOR
.3-L�2rC3-C
Cows7_R'uC7"ION
88 FIELDING DRIVE
M(3NTVILLE, CONNECTICUT
_CALE: AS NOTED FEBRUARY 2006 JOB I.D. N0. 04-1066
REVISION 1 PER UDH COMMENTS 3-14-06
REVISION 2 PER STAFF COMMENTS 3-24-06
SHEET 2 OF 2
COWS'ZRZ L C��O S -y Z,� EXCE
1. SECURE ALL NECESSARY LOCAL, STATE, AND FEDERAL PERMITS.
2. INSTALL CONSTRUCTION ENTRANCE (ANTI -TRACKING PAD), SEDIMENT FENCE AT LOCATIONS REQUIRED. CLEAR
ALL VEGETATION WITHIN THE PROPOSED DEVELOPMENT AREA.
3. GRUB ALL VEGETATION AND DISPOSE OF OFFSITE OR AT AN ONSITE LOCATION APPROVED BY TOWN OF
MONTVWLLE PLANNING DEPARTMENT/WETLANDS STAFF. STRIP ALL ORGANIC MATERIAL FROM THE PROPOSED
DEVELOPMENT AREA AND EITHER STOCKPILE IT FOR FUTURE REUSE AT AN APPROVED LOCATION OR DISPOSE OF
... now low
OFFSITE. TEMPORARILY SEED THIS STOCKPILE AREA WITH RYEGRASS AND INSTALL SEDIMENT AROUND THE
•..
-
DOWNGRADIENT SIDE OF STOCKPILE.
PUBLIC ROAD
4. INSTALL
O°O°°°°°O°°°O°0000 ° 0
BUILDING FOUNDATION AND CONSTRUCT DWELLING.
°°°0� 0�0�0�O�OQ°p°�Op°QOQOp°°
50 MINIMUM 0000°00°00°°°00°
0 0° o 0 0 0 0 0
5. INSTALL SEP77C SYSTEM, WELL AND UTILITIES. PAVE PARKING AND ACCESS DRIVE AREAS. INSTALL CURBING.
°°°O°O°O°O°O°O°O°000000000°0°0°d°°
o°o°o°o°o°o°o°o°o°o°o°0°0°0°0°0°
0 0 0 0 0 0 0 0 0 0 0 0 0 0 o
LOAM ALL DISTURBED AREAS WITH 4" OF TOPSOIL SEED AND MULCH.
,
0 0 0 0 0 0 0 0 0 0 0 0 0
0000000 0 0 0 0 0 0 0 0 0 0 0 0 0
0000 0 0 0 0 0 0 0 0 0 0 0
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
°
o°o°o°o°o°o°o°o°o°o°a°�°o°o°�°�°°
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
0 0 0 0 0 0 0 0 0 0 o 0 0 0 0 0 0 0
6. AFTER ALL AREAS HAVE BEEN PERMANENTLY STABILIZED REMOVE EROSION CONTROL MEASURES.
°°°°°°°°°°°°°°°°°°°°°°°°°°°°o°°
°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°° OT 2"
4" °0°0°0°0°0°0°0°0°0°0°0°0°0°
-
-
- °°°°°°°°°°°°°o°°°°°°
O°O°°°°O°°000°°°°°0°0°°
MINIMUM
- = ° °°0°0°°
EROSION COXTR0.1-, XOTES
FILTER FABRIC
AS
1. ALL UTILITIES ARE APPROXIMATE. CONTRACTOR TO VERIFY ALL UTILITIES PRIOR TO CONSTRUCTION. CONTACT
REQUIRED
"CALL--BEFORE-YOU-DIG" AT 1-800-922-4455 AT LEAST 72 HOURS PRIOR TO ANY EXCAVATION.
(12' MIN.)
2. THE RESPONSIBILITY OF THE INSTALLATION AND MAINTENANCE OF ALL EROSION CONTROL MEASURES IS ROGER HATCH,
PHONE" 1 860-234-7204.
cowss� U CT -TOW EX CE
3. THE "2002 CONNECTICUT GUIDELINES FOR SOIL EROSION AND SEDIMENT CONTROL" BY THE CONNECTICUT COUNCIL ON
-�
SOIL AND WATER CONSERVATION IN COOPERATION WITH THE CONNECTICUT DEPARTMENT OF ENVIRONMENTAL PROTECTION, DEP
NOT TO SCALE
BULLETIN 34, SHALL BE USED FOR INSTALLING AND MAINTAINING ALL EROSION CONTROL MEASURES. THE CONTRACTOR
SHALL INSTALL ADDITIONAL MEASURES AS NECESSARY !F DIRECTED BY THE ENGINEER OR THE TOWN OF MONTVWLLE STAFF.
4. SEEDING FOR PERMANENT STABILIZATION SHALL BE DONE BETWEEN APRIL 15 THROUGH JUNE 15 OR BETWEEN AUGUST 15
THROUGH SEPTEMBER 15. IF SEEDING CANNOT BE DONE WITHIN THESE TIMES, APPLY TEMPORARY MULCH UNTIL NEXT
SEEDING TIME. SEED MIXTURE SHALL BE AS FOLLOWS:
ALL 2:1 SLOPE AREAS
CROWN VETCH 15 LBS/ACRE OR 0.35 LBS/1, 000 SF
PERENNIAL RYEGRASS 10 LBS/ACRE OR 0.25 LBS/1, 000 SF
ALL OTHER GRASSED AREAS
CREEPING RED FESCUE 20 LBS/ACRE OR 0.45 LBS/1,000 SF
REDTOP 2 LBS/ACRE OR 0.05 LBS/1,000 SF
CROWN VETCH 15 LBS/ACRE OR 0.35 LBS/1,000 SF
5. MULCH SHALL BE A GOOD QUALITY HAY OR STRAW AND SHALL BE APPLIED AT A RATE OF 2 EIALES/100 SF.
tt rt r s
L*L*Co
LAND SURVEYING N HISTORICAL LAND RECORD RESEARCH
COMMERCIAL & RESIDENTIAL DEVELOPMENT
P.O. BOX 184
179 PACHAUG RIVER DRIVE
G'RISWOLD, CONNECTICUT 06351
TELEPHONE (860) 376-2006
FAX (866) 376-5899
APPROVED BY THE TOWN OF MON_TVILLE PLANNING
AND ZONING COMMISSION
CHAIRMAN/SECERETARY
DATE
EROSION CONTROL PLAN CERTIFIED BY THE PLANNING
AND ZONING COMMISSION
CHAI RMAN/SECERETARY
DATE
7. APPROVED AGGREGATE SHALL BE STONE AGGREGATE OR OTHER PRODUCTS APPROVED BY THE COMMISSIONER
OF PUBLIC HEALTH. STONE AGGREGATE SHALL BE BROKEN STONE, CRUSHED STONE, OR SCREENED GRAVEL
MEETING THE CONNECTICUT DEPARTMENT OF TRANSPORTATION FORM 816 (OR LATEST REVISION THERETO)
SPECIFICATION M.01.01 FOR NO. 4 STONE, FREE OF SILT, DIRT, OR DEBRIS, SHALL SHOW A LOSS OF ABRASION
OF NOT MORE THAN 50X USING AASHTO METHOD T-96 AND CONFORM TO THE FOLLOWING:
SIEVE SIZE 90 PASSING
2 INCH 10090
1.5 INCH 90 - 100%
1 INCH 20 - 5590
3/4 INCH 0 - 10.E
3/8 INCH 0 - 59
8. NO DEVIATION FROM THE APPROVED DESIGN PLAN SHALL BE ALLOWED WITHOUT PRIOR APPROVAL FROM THE
UNCAS HEALTH DISTRICT AND THE DESIGN ENGINEER.
9. THE SEPTIC TANK SHALL BE PRECAST CONCRETE UNLESS OTHERWISE AUTHORIZED BY THE DESIGN ENGINEER.
10. SITE PREPARATION PROCEDURE FOR THE INSTALLATION OF THE PROPOSED SEPTIC SYSTEM:
A. STRIP ALL TOPSOIL, VEGETATION AND ORGANIC MATERIAL IN THE AREA OF AND 5' SURROUNDING THE
PRIMARY LEACHING TRENCHES.
B. USING A HEAVY RAKE OR EQUAL, THOROUGHLY SCARIFY AND ROUGHEN UP THE EXPOSED SUBSOIL.
PREVENT ANY VEHICULAR TRAFFIC, BACKHOE, TRUCKS, ETC. FROM SMOOTHING/COMPACTING THIS EXPOSED
SUBSOIL.
C. PLACE AND COMPACT SELECT FILL MATERIAL MEETING SPECIFICATIONS INDICATED ABOVE (NOTE 16) IN LIFTS
OF NOT GREATER THAN 12" IN THE AREA OF THE PROPOSED LEACHING TRENCHES UP TO AT LEAST THE
ELEVATION OF THE TOP OF THE LEACHING TRENCHES.
D. PERFORM AT LEAST 1 PERCOLATION TEST ON PLACED FILL. FILL MUST HAVE A PERCOLATION RATE EQUAL
TO OR FASTER THAN THAT AS INDICATED IN NOTE #6.D. IF PERCOLATION RATE IS SLOWER THAN THAT RATE, ALL
FILL SHALL BE REMOVED AND REPLACED WITH ACCEPTABLE FILL MEETING PROPER SPECIFICATIONS.
E. INSTALL SEPTIC SYSTEM PER PLAN USING APPROVED AGGREGATE AS INDICATED IN NOTE 17.
F. COVER SYSTEM WITH A MINIMUM OF 6" OF LOAM IN LAWN AREAS, GRADE TO PREVENT PONDING AND SEED
WITH GRASS TO STABILIZE. THE FINISHED GRADE 10' FROM ANY PART OF THE PROPOSED LEACHING TRENCHES
SHALL BE AT LEAST THE SAME ELEVATION AS THE TOP OF THE RESPECTIVE LEACHING TRENCH.
G. CLEANOUT MANHOLES AT THE INLET BAFFLE AND AT THE OUTLET FILTER OF THE SEPTIC TANK OR
ASSOCIATED RISERS AT THESE LOCATIONS IF REQUIRED SHALL BE LOCATED AT A DEPTH NOT GREATER THAN 12"
BELOW FINAL GRADE.
11. FOR EXACT HOUSE DIMENSIONS, SEE BUILDING PLANS.
12. PRIOR TO THE START OF CONSTRUCTION, THE HOUSE AND SEPTIC SYSTEM SHALL BE STAKED OUT BY A LICENSED
LAND SURVEYOR.
XOTE'S AWD DE7.AILS
PREPARED FOR
.3-L�2rC3-C
Cows7_R'uC7"ION
88 FIELDING DRIVE
M(3NTVILLE, CONNECTICUT
_CALE: AS NOTED FEBRUARY 2006 JOB I.D. N0. 04-1066
REVISION 1 PER UDH COMMENTS 3-14-06
REVISION 2 PER STAFF COMMENTS 3-24-06
SHEET 2 OF 2