HomeMy WebLinkAboutImprovement & Topo Planw a car co 0 N 0 0 N h N N -a 0 i h Cl 3 0 m L, 0 0 Ln 'r0 ,'I - 0 i to 0 0 N V) w 0 0L 0 0 J i a_ 0 I'— � - �___ - �L_ - �__ - � <,: I SEE So?' N W F.. 2 2�EEP 2-ESj-' PIS AND PERCOLA�1"ON TEST RESuLT-S' ALL SOIL DATA WAS TAKEN FROM REFERENCE MAP 4.A. DEEP TEST PITS WERE RECORDED BY ROBERT RUSSO OF CLA ENGINEERS, 11-30-04. PERCOLATION TEST WAS PERFORMED BY CLA ENGINEERS ON 6-16-05. TEST PIT j 132 0"- 3" TOPSOIL DARK BROWN FINE SANDY LOAM 3"- 54" SUBSOIL STRONG BROWN STONY SANDY LOAM NO GROUNDWATER, LEDGE 0 54" NO MOTTLING TEST PIT j 133 0"- 3" TOPSOIL DARK BROWN FINE SANDY LOAM 3"- 40" SUBSOIL YELLOW BROWN SANDY LOAM W/ MOTTLES 40"- 69" GRAY SANDY TILL NO GROUNDWATER, NO LEDGE, MOTTLING 0 28" TEST PIT j 134 0"- 4" TOPSOIL DARK BROWN FINE SANDY LOAM 4"- 41" SUBSOIL YELLOW BROWN SANDY LOAM W/ MOTTLES 41"- 72" GRAY SANDY TILL NO GROUNDWATER, NO LEDGE, MOTTLING 0 28" TEST PIT j 135 0"- 4" TOPSOIL BROWN FINE SANDY LOAM 4"- 25" SUBSOIL STRONG BROWN STONY SANDY LOAM 25"- 76" GRAY SANDY TILL BOULDERS NO GROUNDWATER, NO LEDGE, MOTTLING 0 25" PERC TEST #9 DEPTH = 24" RUE ffEAl 10:22 12" 10:25 13-1/2" 10:28 15-1/4" 10:31 16-1/2" 10:34 17-112" 10:37 18-1/2" 10:40 19-1/4" 10:43 20" 10:46 20-3/4" 10:49 21-1/2" 10.52 22" 10:55 22-1/f " 10:58 DRY PERCOLATION RATE 0 24" DEPTH = 6.0 MINUTES/INCH SYLWITARY D ES_TC�W CR_RrER_TA_ PROPOSED 4 BEDROOM HOUSE DESIGN PERCOLATION RATE = 6.0 MINUTES/INCH LEACHING AREA REQUIRED = 660 SF EFFECTIVE DESIGN: 1,250 -GALLON CONCRETE SEPTIC TANK (MINIMUM) AND 1 ROW OF 112' OF 4' WIDE, 8' LONG, 12" HIGH CONCRETE LEACHING GALLERIES WITH 1' OF APPROVED AGGREGATE SURROUNDING ALL SIDES. LEACHING AREA Phi'0 DED. i i 5' „ 5.9 SF L" = 66{4.4 SC 100% RESERVE AREA PROVIDED -MISS CAI CU1111-1110iv HYDRAULIC GRADIENT = 10.0% DEPTH TO RESTRICTIVE LAYER = 25" HYDRAULIC FACTOR = 28 FLOW FACTOR FOR 4 BEDROOMS = 2.0 PERCOLATION FACTOR FOR 5.1-10.0 MINUTES/INCH = 1.2 MLSS REQUIRED = 67.2' MLSS PROVIDED = 110' 10' TO TOP OF EMBANKMENT - 4'x 8°x 12" HIGH CONCRETE LEACHING GALLERIES APPROVED AGGREGATE TO FAWN'S MEADOW ROAD SUR-VEY J OSES \ \ \ \ 1. THIS SURVEY AND MAP HAVE BEEN PREPARED PURSUAI tT TO THE REGULATIONS OF CONNECTICUT STATE AGENCIES SECTIONS 20-300b-1 THROUGH 20-300b-20AND THE "STANDARDS FOR SURVEYS AND MAPS 1N THE STATE OF CONNECTICUT" AS ADOPTED FOR USE BY THE CONNECTiCUT ASSOCIATION OF LAND SURVEYORS INC. ON SEPTEMBER \ \ \ 26TH 1996. IT IS AN "IMPROVEMENT LOCATION AND TOPOGRAPHIC SURVEY" BASED ON DEPENDENT RESURVEY AND \ \ \ \ \ CONFORMS TO HORIZONTAL CLASS A-2 AND TOPOGRAPHIC CLASS T-2 ACCURACY STANDARDS. IT IS INTENDED TO BE \ \ \ \ USED FOR SITE DEVELOPMENT. \ \ \ \ \ 2. PROPERTY LINES, BUILDING SETBACK LINES, EASEMENT ? INES, LIMIT OF INLAND WETLANDS AND NORTH ORIENTATION \ \ \ \ \ \ \ WERE DERIVED FROM REFERENCE MAP 4A. TOPOGRAPHY WAS DERIVED FROM REFERENCE MAP 4A AND LIMITED \ \ \ \ \ \ \ \ \ TOPOGRAPHIC FIELD SURVEY. \ \ \ \ \ \ \ \ \ 3. THE SUBJECT PROPERTY LIES WITHIN R-120 ZONE (CLOISTER DEVELOPMENT), HAVING THE FOLLOWING DIMENSIONAL REQUIREMENTS: \ \ \ \ \ \ \ r MINIMUM LOT SIZE 80,000 SQ. FT. t \ \ \ \ \ \ MINIMUM LOT FRONTAGE 150 FEET MINIMUM FRONT YARD 45 FEET MINIMUM SIDE YARD 18.75 FEET \ \ \ \ 1 \ \ \ MINIMUM REAR YARD 45 FEET 4. REFERENCE MAP: \ \ \ \ \ A. RESUBDIVISION PLAN, FAWN'S VIEW, LYNCH HILL ROAD, MONTWLLE, CONNECTICUT, PREPARED FOR STONEHENGE PILLARS, LLC, JUNE 2005, REVISED TO JANUARY 13, 2006, SHEETS 1 THROUGH 16, PREPARED BY CLA ENGINEERS, INC. 5. THIS SITE IS LOCATED IN AN R-120 ZONE AND IS PARY OF AN APPROVED CLUSTER SUBDIVISION WHERE THE BUILDING SETBACKS ARE REDUCED BY 25% OF THE REQUIRED R-120 SETBACK REQUIREMENTS AS INDICATED ABOVE. WF#49F / // l l WF,447F gti ��, \ \ I � \ \ \ ` I WFI15 OF \ LOT \ \ t t I INLAND WETLANDS (SEE SURVEY NOTE 12) \ \ \ \ LOT 7/ / ! I I AREA: 10.301 1• ACRES 448,740± S. F. t� I I I t J INV 335.0± WITH / / I PERFORATED END ` \ WF#51 F - -_ IX CAP 17'-4" PVC I t \ \ - / / t FOOTING DRAIN ` \ _ \ \ CZ OUTLET PIPE - rd, \ \ \ / \ S - 0.1± \ \ ---------- \ \\ \ \ 30'-4" PVC j \ 342 SCHED 40 S= 114 IFT / - \ 'PROPOSED 1,250 GALLON SEPTIC TANK \ \ � � ' 8\ GARAGE \ \ INV 335.25 IN , = -33® \ \ SEDIMENT \ PROPOSED CLEARING \ \ FF 345.20 3 \� INV 335.00 oUT\ % \ FENCE \ \ LIMIT (TYP) \ v PROPOSED 4 3 4 -5-. _0j / BEDROOM HOUSE X FF BSMT 337.0 337.7 \ \ F ¢Ol 66' S13'0937"W i ♦ 17' N75'16'09"E i 41. 25.35' 4' N 13'09'37"E ♦♦ 41.35' ♦ \ ♦ 1 LIMIT OF DRIVEWAY EASEMENT /(�SEpE REFERENCE MAP 4.A.) -�♦r, lT yr) FINISHED GRADE LOAM AND SEED, GRADE TO PREVENT PONDING - FILTER FABRIC 24" MIN. TO MOTTLING/OR GROUNDWATER 48" MIN. TO LEDGE/ROCK 4'x8'xI2 " H_TGH COXCRETE l EACH-TwG G -Al -E ERY NOT TO SCALE joun rtrs L.L.C. LAND SURVEYING - HISTORICAL LAND RECORD RESEARCH COMMERCIAL & RESIDENTIAL DEVELOPMENT P.O. BOX 184 179 PACHAUG RIVER DRIVE GRISWOLD, CONNECTICUT 06351 TELEPHONE (860) 376-2006 FAX (860) 376-5899 O 2009 BOUNDARIES LLC THIS DRAWING IS THE PROPERTY OF BOUNDARIES LLC AND HAS BEEN SPECIFICALLY PREPARED FOR THE OWNER OF THIS PROJECT, AT THIS SITE, AND IS NOT TO BE DUPLICATED OR USED IN PART OR WHOLE FOR ANY OTHER PURPOSE, PROJECT, LOCATION OR OWNER WITHOUT THE EXPRESSED WRITTEN CONSENT OF BOUNDARIES LLC. i i i � LOT 1o\ BOTTOM OF ALL -LEACHING GALLERIES _ - ELEV 327.50 D -BOX -348 \ \ (ASSUMED DATUM) ``� r i "'� \ / \ `� � � � INV 328.17 INS \ INV 328.00 OUT APPROXIMATE \ �' \ - - - \ \ �` \ \ 1009 RESERVE \ LOCATION OF AREA \ EXISTING TREELINE Xr I TTW T TT A I-rM APC - '• 4 sp - FILTER FENCE ` -_ __----- W a J Roaktand LOCATION MAP SCALE: 1 "=1000' CEWEAAI WOTTS 1. THIS SEPTIC SYSTEM INSTALLATION INCLUDING ALL MATERIALS (PIPING, SEPTIC TANK, STONE, FILL, ETC.) USED FOR THIS SEPTIC SYSTEM SHALL CONFORM TO THE CURRENT EDITION/REVISION OF THE 'TECHNICAL STANDARDS FOR SUBSURFACE SEWAGE DISPOSAL SYSTEMS" REVISED JANUARY 1, 2009 OF THE CONNECTICUT PUBLIC HEALTH CODE BY THE STATE OF CONNECTICUT DEPARTMENT OF PUBLIC HEALTH. 2. THE PROPOSED HOUSE SEWER FROM THE BUILDING TO THE SEPTIC TANK SHALL BE SCHEDULE 40 PVC ASTM D 1785/ASTM D 2665 OR APPROVED EQUAL AND INDICATED IN TABLE NO. 2 OF 'TECHNICAL STANDARDS FOR SUBSURFACE SEWAGE DISPOSAL SYSTEMS" ALL OTHER SEWER PIPE FOR THIS SEPTIC SYSTEM SHALL BE 4" PVC ASTM D3034, SDR 35 WITH RUBBER COMPRESSION GASKET OR BELL AND SPIGOT OR APPROVED EQUAL 3. THERE ARE NO WELLS (POTABLE, GEOTHERMAL, OR IRRIGATION) WITHIN 75' OF THE PROPOSED SEPTIC SYSTEM. THERE ARE NO SEPTIC SYSTEMS WITHIN 75' OF THE PROPOSED WELL. 4. THERE SHALL BE NO STUMPS OR BOULDERS BURIED WITHIN 50' DOWN GRADIENT OF THE SEPTIC SYSTEM. SHOULD ANY SIGNIFICANT VARIATIONS FROM THE TEST HOLE DATA BE ENCOUNTERED DURING EXCAVATIONS (LEDGE, GROUNDWATER, MOTTLING, SOIL TYPE, ETC.), THE DESIGN ENGINEER SHALL BE NOTIFIED PRIOR TO INSTALLATION OF THE SEPTIC SYSTEM. 5. ALL EXISTING UTILITIES ARE APPROXIMATE ONLY. THE CONTRACTOR SHALL VERIFY ALL UTILITY LOCATIONS AND ELEVATIONS PRIOR TO ANY CONSTRUCTION. CONTRACTOR SHALL CONTACT "CALL -BEFORE -YOU -DIG" AT 1-800-922-4455 AT LEAST 48 HOURS PRIOR TO ANY EXCAVATION. 6. THE PROPOSED FILL FOR THIS SEPTIC SYSTEM SHALL MEET THE FOLLOWING SPECIFICATIONS: A. 1007. OF FILL SHALL PASS THROUGH A 3" SIEVE. B. MAXIMUM % OF GRAVEL (BETWEEN #4 & 3" SIEVE) = 457.. C. GRADATION OF FILL WITHOUT THE GRAVEL SHALL MEET THE FOLLOWING CRITERIA: SIEVE SIZE % PASSING (WETS % PASSING (DRY, #4 100% 100% # 10 70 - 1007. 70 - 1007o #40 10 - 507.* 10 - 75% #100 0 - 207. 0 - 5% #200 0 - 5% 0 - 2.5% D. * PERCENT PASSING THE #40 WET SIEVE CAN BE INCREASED TO NO GREATER THAN 75% IF THE PERCENT PASSING THE #100 SIEVE DOES NOT EXCEED 107. AND THE #200 SIEVE DOES NOT EXCEED 5 E. PERCOLATION RATE AFTER PLACEMENT AND COMPACTION SHALL- BE FASTER PIAN OR EQUAL TO 10.0 MIP.,UTES/INCE'. A WET Or? DRY SI/:VE ANALYSIS MAY BE EQUlRLf.' PP,iOR TO FILL rLACEMENI TO 'VEF;IF" THAT IT MEETS THESE SPECIFICATIONS, THE FILL SHALL BE APPROVED BY THE UNCAS HEALTH DISTRICT OR DESIGN ENGINEER PRIOR TO ITS PLACEMENT ON SITE. 7. APPROVED STONE AGGREGATE MEANS CRUSHED OR BROKEN STONE, OR CRUSHED AND UNCRUSHED GRAVEL MEETING THE GRADATION FOR NO. 4 (1114" STONE) OR NO. 6 (3/4" STONE) AGGREGATE PER DEPARTMENT OF TRANSPORTATION FORM 816 SPECIFICATION M.01.01 (OR LATEST SPECIFICATION), AND THE 140 AND #200 SIEVE GRADATION STIPULATED IN SECTION V111 A, BASED ON A WET SIEVE ANALYSIS. STONE AGGREGATE SHALL BE FREE OF SILT, DIRT OR DEBRIS, AND SHALL SHOW A LOSS OF ABRASION OF NOT MORE THAN 50 % USING AASHTO METHOD T-96, AND WHEN TESTED FOR SOUNDNESS USING AASHTO METHOD T-104 NOT HAVE A LOSS OF MORE THAN 15% AT THE END OF 5 CYCLES. NO. 4 AGGREGATE NO. 6 AGGREGATE* SIEVE SIZE 9 PASSING % PASSING 2 INCH 100% N/A 1.5 INCH 90 - 100% N/A 1 INCH 20 - 55% 100% 3/4 INCH 0 - 15% 90 - 100% 1/2 INCH N/A 20 - 55% 3/8 INCH 0 - 5% 0 - 157. #4 N/A 0-5% #40 0 - 37. 0 - 3% #200 0 - 1.57. 0 - 1.59 * NO. 6 AGGREGATE IS ONLY APPROVED TO BE USED FOR LEACHING TRENCHES AND PROPRIETARY SYSTEMS ONLY. 8. NO DEVIATION FROM THE APPROVED DESIGN PLAN SHALL BE ALLOWED WITHOUT PRIOR APPROVAL FROM THE UNCAS HEALTH DISTRICT AND THE DESIGN ENGINEER. 9. THE SEPTIC TANK SHALL BE PRECAST CONCRETE UNLESS OTHERWISE AUTHORIZED BY THE DESIGN ENGINEER. 10. SITE PREPARATION PROCEDURE FOR THE INSTALLATION OF THE PROPOSED SEPTIC SYSTEM: A. STRIP ALL TOPSOIL, VEGETATION AND ORGANIC MATERIAL IN THE AREA OF AND 5' SURROUNDING THE PRIMARY LEACHING GALLERIES. B. USING A HEAVY RAKE OR EQUAL, THOROUGHLY SCARIFY AND ROUGHEN UP THE EXPOSED SUBSOIL. PREVENT ANY VEHICULAR TRAFFIC, BACKHOE, TRUCKS, ETC. FROM SMOOTHING/COMPACTING THIS EXPOSED SUBSOIL. C. PLACE AND COMPACT SELECT FILL MATERIAL MEETING SPECIFICATIONS INDICATED ABOVE (NOTE #6) IN LIFTS OF NOT GREATER THAN 12" IN THE AREA OF THE PROPOSED LEACHING GALLERIES UP TO AT LEAST THE ELEVATION OF THE TOP OF THE LEACHING GALLERIES. D. PERFORM AT LEAST 1 PERCOLATION TEST ON PLACED FILL. FILL MUST HAVE A PERCOLATION RATE EQUAL TO OR FASTER THAN THAT AS INDICATED IN NOTE #6.E. 1F PERCOLATION RATE IS SLOWER THAN THAT RATE, ALL FILL SHALL BE REMOVED AND REPLACED WITH ACCEPTABLE FILL MEETING PROPER SPECIFICATIONS. E. INSTALL SEPTIC SYSTEM PER PLAN USING APPROVED STONE AGGREGATE AS INDICATED IN NOTE #7. F. COVER SYSTEM WITH A MINIMUM OF 8" OF LOAM IN LAWN AREAS, GRADE TO PREVENT PONDING AND SEED WITH GRASS TO STABILIZE. THE FINISHED GRADE 10' FROM ANY PART OF THE PROPOSED LEACHING GALLERIES SHALL BE AT LEAST THE SAME ELEVATION AS THE TOP OF THE RESPECTIVE LEACHING GALLERY. G. CLEANOUT MANHOLES AT THE INLET BAFFLE AND AT THE OUTLET FILTER OF THE SEPTIC TANK OR ASSOCIATED RISERS AT THESE LOCATIONS IF REQUIRED SHALL BE LOCATED AT A DEPTH NOT GREATER THAN 12" BELOW FINAL GRADE. 11. FOR EXACT HOUSE DIMENSIONS, SEE BUILDING PLANS. 12. BENCHMARK TO BE LOCATED IN THE AREA OF DEVELOPMENT PRIOR TO THE START OF CONSTRUCTION. 13. PRIOR TO CONSTRUCTION, THE HOUSE, WELL, AND SEPTIC SYSTEM SHALL BE STAKED OUT BY A LICENSED LAND SURVEYOR. II ± UTILITY POLE MORE OR LESS BSMT BASEMENT SANITARY vel ont-nrILL _ GRAPHIC SCALE ��.. T`M PROTE!A410 C,i��OJN SAN. FT FEET INV. INVERT . , 20 0 10 20 40 80 - - - - - - -AND- REC. RECOVERED ELEV. ELEVATION EXCAVATE 6"x 6" TRENCH : >'-., , .1: IN FEET) //////■■�/ OPO R.APHIC SURTEY PVMT. PAVEMENT W� WITH FLOW )' :� : ( - - _ I. :, _ I inch = 20 ft. 7YP. TYPICAL BUILDING SETBACK UNE : T_ EXISTING GRADE PREPARED FOR PVC S. F. POLYVINYL CHLORIDE SQUARE FEET _ EXISTING CONTOUR 12" MIN. SloEW E P111 m_ PROPOSED CONTOUR DEPTH UNDISTURBED 'TO MY KNOWLEDGE AND BELIEF THIS MAP IS SUBSTANTIALLY CORRECT AS NOTED HEREON." FF FINISHED FLOOR �- PERCOLATION TEST GROUNDa 23 FAWN'S MEADOW ROAD LOT #8 DEEP TEST PIT 1P IRON PIPE MONTVILLE, CONNECTICUT 345.0 X PROPOSED SPOT GRADE MON. MONUMENT SED1 M �E� E NCE D EJ .Vl 7(7234 L- NOT TO SCALE . SCALE. 1 "-20' JUNE 2009 JOB I.D. NO. 06-1450-L0T7y8 SEAN T. t3P(7p<; S. LICENSE N0. DATE