HomeMy WebLinkAboutSewer PlanLEGEND:
TH#163 - 0"-5" TOPSOIL
F.F.
FIRST FLOOR
EL.
ELEVATION
S.F.
SQUARE FEET
TYR
TYPICAL
IPIN
TRON PIN
MON
MONUMENT
DH
DRILL HOLE
x93.5
EXISTING SPOT ELEVATION
x94.5
PROPOSED SPOT ELEVATION
90
EXISTING CONTOURS
90
PROPOSED CONTOURS
BUILDING SETBACK LINE
TEST HOLE
ENGINE& DATE
SNET
#784
rw"vLuz ft 1_,"n itiNu%ju a j_u,4u
OF SILT FENCE (SEE DETAIL)
LIMITS OF , INLAND VVETL2
(PER REF. MAP)
ut
%
55
5r,
6
cr_
Go
TO W KWTMM0E 4NDPELIEF, THIS MAP IS SUBSTANTIALLY CORRECT
AS NOT I IS NOT VALID WITHOUT A LIVE SIGNATURE
AND T OTHE SURVEYOR HEREON.
l
RICH A, ESCHAMPS L.9, #70019 LTE'
50'
REG-LTLATEb
Cb"
76
Ao
2X2 5/8 16 GA. WIRE MESH
I LIT'
:2
CIN
TEST HOLE DATA
u .1M 11 a lu gm NJ Lol k! 9 9
TH*161 - 0"-6" TOPSOIL
TH#163 - 0"-5" TOPSOIL
- 6"-27" BROWN SANDY LOAM
- 5"-24" BROWN SANDY LOAM
- 27-52" VERY FINE SAND
- 24"-72" TAN/OLIVE VERY FINE SAND
- 52"-81" SAND AND GRAVEL
NO WATER, MOTTLING(&24", NO LEDGE
WATER(a)
,78, MOTTLING@27, NO LEDGE
RESTRICTIVE LAYER @24
RESTRICTIVE LAYER @27""
LL
TH#162 - 0"-7" TOPSOIL
TH#164 - 0"-6" TOPSOIL
- 7-22" BROWN SANDY LOAM
- 6"-.'24" BROWN SANDY LOAM
- 22"-4I`VERY :FINE SAND
- 24"-50" FINE, SAND NV,/LENSES OF SILT
- 41 "-70" SAND AND GRAVEL
- 50"-84" SAND AND GRAVEL
WATER@68", MOTTLING@22", NO LEDGE
NO WATER, MOTTLING @24", NO LEDGE
RESTRICTIVE LAYER @221I ?
RESTRICTIVE. LAYER @24"
4" PVC ELBOW
(CUT FOR 4" OVERFLOW)
�1 1 2"
STANDARD D -BOX WELBOW
NOT TO SCALE
NFINOW07111 W-.
PER SUBDIVISION PLAN
DEPTH -18""
TIME
151-63"4"1- }H
10 - 61/2""
20-811
30-9I4"'
40 - 10 ILYt
50 -11,3 f441
60 - i 31
09mmm
3 BEDROOM HOUSE
SLOPE -14%
PERC, P ATE - 8 MIN./ NCH
RESTRICTIVE LAYER - 22"
Ml.&& REQUIRED - 26 x 1.5 x 1.2 = 46.8'
M.L.S.S. PROVIDED - 831
:3 BEDROOM HOUSE REQUIRES 495 S.F.
OF EFFECTIVE LEACHING AREA
USE (2) - 83'LONG 48" WIDE STONE TRENCHES
(83 x 2 x 3 = 498 SR)
USE 1,000 GAL 2 COMPARTMENT SEPTIC TANK
W/ OUTLET FILTER DEVICE
SEPTIC SYSTEM INVERTS
(—I) - 81.85 MIN, OUTLET AT HOUSE
(2) - 81.25 INLET @ TANK
C3) - 81.00 OUTLET (a-) TANK
(4) - 80,50 INLET & TRENCH RqVERT (BOTTOM TRENCH EL. -80.00) EXIST. GRADE - 803
HI -LEVEL OVERFLOW - TOP OF ELBOW EL. -80,80
(3) - 78.70 INLET & TRENCH INVERT (BOTTOM TRENCH EL. -78.20) EXIST. GRADE - 78.5
WSW
COMPACTED
BACKFILL—'
CONNECTICUT NPPRO'vED--------
FILTER FABRIC
4" PERFORATED
PIPE --
STONE AGGREGATE
(SFE NOTES)
ANGLE 10" UP SLOPE
FOR STABILITY AND
N s SELF CLEANING
SILT FENCE
NOT TO SCALE
TOPSOIL
KNOCKOUT INLETAND
OUTLET OPENINGS
2?1
SUITABLE FML
RIBS INSIDE,
cb
+
k 'M K#
malloco
CAST
CONCRETE COVERS
PLAN,
4 x 4 12.6/12.6 G.A. NVIRE MESH
1
17 1/2", 6 x 6 6 , 6 GA, WIRE MESH
KNOCKOUT INLETAND
OUTLET OPENINGS
3'1 VENT E' 3" VENT
RIBS INSIDE,
LEVEL—���_
+
—LIQUID
C 4' OUTLET
CONTINUOUS HOT
LL
CAST
CONCRETE COVERS
PLAN,
4 x 4 12.6/12.6 G.A. NVIRE MESH
1
17 1/2", 6 x 6 6 , 6 GA, WIRE MESH
-1-000GA44ON,
2 COMPARTMENT
SEPTIC TANK
NOT TO SCALE
1-4""
TOUTLET
OUTLET
FILTER
DEVICE
ti 4
311
EROSION AND SEDIMENT CONTROL PLAN:
1. CLEARING, GRUBBING, AND GRADING OF THE PROPOSED SITE
TO BE LIMITED TO AREAS ADJACENT TO THE PROPOSED HOUSE
AND SEPTIC SYSTEM.
2, DISTURBED AREAS TO BE LOAMED, SEEDED, AND MULCHED,
3. ALL TOPSOIL TO BE STOCKPILED ON SITE AND PROTECTED
WITH HAYBALES OR SILT FENCE.
4. ALL CUT AND FILL SLOPES ARE NOT TO EXCEED 3:1 SLOPES.
5. PRIOR TO SITE DISTURBANCE, THE REPRESENTATIVE OF THE
TOWN OF MONTVILLE SHALL BE NOTIFIED WHEN SEDIMENT
CONTROL MEASURES ARE IN PLACE SO THAT THE INSPECTION
CAN OCCUR.
6, THE CONTRACTOR WILL, BE RESPONSIBLE FOR THE INSTALLATION
AND MAINTENANCE OF ALL REQUIRED SEDIMENT CONTROL
MEASURES THROUGHOUT CONSTRUCTION.
7, DUST CONTROL WILL BE ACCOMPLISHED BY SPRAYING WITH
WATER, AND IF NECESSARY THE APPLICATION OF CALCIUM CHLORIDE.
TEMPORARY VEGETATIVE COVER:
MULCHES APPLICATION RATE
PER 1000 SY,
STRAW/HAY 70-90 lbs.
WOOD CHIPS 185-275 lbs.
PLANTING SCHEDULE:
SEEDING DATES:
APRIL I ------- JUNE 15
AUGUST ------ SEPTEMBER 15
SEED MIXTURE:
450% RED FESCUE
45% KENTUCKY BLUE GRASS
10% PERENNIAL RYE
DESIGN NOTES:
FREE FROM WEEDS
AND COARSE MATTER
FREE OF COARSE MATTER
AIR DRIED, TREAT WITH
12lbs NITROGEN / TON
t' ALI, CONSTRUCTION TO CONFORM TO STANDARDS OF THE CONNECTICUT
PUBLIC HEALTH CODE AND TO THE SATISFACTION OF THE ToAN sANATARI-AN,
2, THIS SYSTEM HAS NOT BEEN DESIGNED FOR THE USE OF LARGE
CAPACITY (-100 GALLONS), DISCHARGE TYPE BATHTUBS. RESIDENTIAL
GARBAGE DISPOSALS ARE NOT ANTICIPATED FOR THIS DESIGN. IN THE
EVENT THAT SUCH AN INSTALLATION IS CONTEMPLATED FOR THE
PROPOSED HOUSE, A LARGER SEPTIC TANK AND INCREASED LEACHING
FIELD CAPACITY WILL BE REQUIRED.
LEACHING SYSTEM CONSTRUCTION NOTES:
1, TOPSOIL TO BE STRIPPED OFF PRIOR TO FILLING, FILL MATERIAL BETWEEN AND BEYOND
TRENCHES 10 BE PERVIOUS, GOOD QUALITY AND CLEAN MEDIUM SAND (SELECT FILL) PLACED
AND COMPACTED IN 6" LIFTS. SELECT FILL SHALL MEET THE FOLLOWING MINIMUM REQUIREMENTS:
A. THE FILL SHALL NOT CONTAIN ANYAlATERikL LARGER THAN 3 INCHES,
B, THE FILL SHALL NOT CONTAIN MORE THAN 45 PERCENT GRAVEL (GRAVEL IS BETWEEN NO, 4 & Y SIEVES)
NO MORE THAN 45 PERCENT OF THE MATERIAL CAN BE RETAINED ON THE NO, 4 SIEVE.
C, THE FILL LESS THE GRAVEL SHALL MEET THE FOLLOWING GRADATION CRITERIA:
SIEVE SIZE: #4 #10 F40 #100 #200
% PASSING:100 70-100 **10-50 0-20 0.5 WET SIEVE
% PASSING: 100 70-100 10-75 0-5 0-2.5 DRY SIBT
PERCENT PASSING THE #40 SIEVE CAN BE INCREASED TO NO GREATER THAN 75% IF THE PERCENT
PASSING THE #100 SIEVE DOES NOT EXCEED 10% AND THE #200 SIEVE DOES NOT EXCEED 5%.
2. DOCUMENTATION OF TEST RESULTS ARE TO BE PROVIDED TO THE HEALTH. DISTRICT.
3. FILL MATERIAL TO BE PLACED PRIOR TO TRENCH EXCAVATION, NO TRAFFIC OTHER THAN
TRACK -DRIVEN EQUIPMENT IS TO CROSS, DUMP, UNLOAD OR OTHERWISE CONTACT THE FILL AREA
AFTER TOPSOIL REMOVAL. FILL MATERIAL TO BE DUMPED AT THE EDGE OF THE STRIPPED AREA AND
SPREAD AND COMPACTED WITH TRACK -DRIVEN VEMCLES, STOCKPILING IS TO TAKE PLACE UPGRADIENT OF
THE LEACHING AREA. THEAREA, DOWN GRADIENT OF THE LEACHING AREA IS NOT TO BE DISTURBED.
SEPTIC SYSTEM CONSTRUCTION NOTES:
1. CONSTRUCTION SEUTNqE_;
A. STRIP & STOCKPILE TOPSOIL FROM: LEACHING TRENCH AREA.
B, PLACE SELECT FILL TO 6" BELOAT EXISTING GRADE.
C. AFTER FILL IS PLACED AND CONTACTED A PERC TEST IS TO BE PERFORMED.
D, A PER TEST IS TO BE PERFORMED IN THE RESERVE AREA,
E. CONSTRUCT LEACHING TRENCHES TO DESIGN LINE & GRADE,
F. LOAM, FINE GRADE TO FINISHED GRADE AND SEED, PROTECT DISTURBED AREAS
INITH EROSION CONTROLS UNTIL FIRST MOINING.
2. THE PIPE BETWEEN THE HOUSE AND SEPTIC TANK SHALL BE 4 IN. EXTRA HEAVY CAST IRON,
DUCTILE IRON OR EXTRA STRENGTH PVC ASTM D1.785 SCHD 40 OR APPROVED EQUAL.
3. ALL DISTRIBUTION PIPE IS TO BE ASTM D3034 SDR 35 (4"PVC) OR APPROVED EQUAL UNLESS NOTED.
4, SEPTIC TANK SHALL BE SET LEVEL ON A MINIMUM OF 6" OF PROCESSED GRAVEL, OR BROKEN
STONE ON COMPACTED SUBGRADE.
5. THERE ARE NO APPARENT WELLS OR SEPTIC FIELDS WITHIN 75" OF THE PROPOSED NVELL AND
SEPTIC SYSTEM AS SHOWN ON THIS PLAN.
6. APPROVED STONE, AGGREGATE FOR LEACHING TRENCHES SHALL BROKEN STONE, CRUSHED
STONE, OR SCREENED GRAVEL MEETING CT DOT FORM 814A SPECIFICATION FOR M.0 1.0 1 FOR NO. 4
STONE: STEVE SIZE PERCENT PASSING
,
- _P.Y--_ NVEIGHT)
2 -INCH 100
1 -1/2 -INCH 90-100
1 -INCH 20-55
3/4 -INCH 0-15
3/8 -INCH 0-5
#40 0-3
#200 0-1.5
7. THE LOCATION AND ELEVATION OF THE PROPOSED SEPTIC SYSTEM AND HOUSE SHALL BE STAKED
IN THE FIELD BY A LICENSED LAND SURVEYOR.
8. THE BOTTOM OF THE LEACHING TRENCHES ARE NOT TO EXCEED 6" INTO EXISTING GRADE.
1. TOPOGRAPHIC INFORMATION ON THIS PLAN COMPLIES WITH T-2 MAPPING
STANDARDS,
2, PROPOSED HOUSE AND SEPTIC SYSTEM TO BE STAKED IN THE FIELD BY
A LAND SURVEYOR LICENSED IN THE STATE OF CONNECTICUT
3. BASE FOR LEVELS: PER REFERENCE NIAP.
4. PROPERTY IS LOCATED IN THE TOWN OF MONTVILLE ZONING DISTRICT R-80.
5. THERE .ARE NO'%TELLS LOCATED WITHIN '175'OF THE PROPOSED SEPTIC SYSTEM
LOCATED ON ABUTTING PROPERTIES.
6, A BENCHMARK IS TO BE PLACED WITHIN 50" OF THE PROPOSED HOUSE &
SEPTIC SYSTEM AT THE TIME OF CONSTRUCTION,
9. IF BLASTING IS NECESSARY A PRE -BLAST SURVEY SHALL BE REQUIRED
PRIOR TO THE, START OF CONSTRUCTION,
REFERENCE MAP:
SUBDIVISION PLAN PREPARED FOR ELIZABETH PATRICIA SHEEHAN
MASSAPEAG ROAD, MONTVILLE, CONNECTICUT, SCALES AS NOTED
REVISED TO 12/27/07, PREPARED BY CME ASSOCIATES, INC,
3'1 VENT E' 3" VENT
LEVEL—���_
—LIQUID
C 4' OUTLET
CONTINUOUS HOT
BAFFLE
B
"va 34
ASPHALT SEAL - LINED WITH
1/8PITCI
4-" SCHEDIJLE 440 "
M U LET BAYFLI 60° GAS
DEFLECTO
. . . ........ ....... .
4,
CROSS SECTION
-1-000GA44ON,
2 COMPARTMENT
SEPTIC TANK
NOT TO SCALE
1-4""
TOUTLET
OUTLET
FILTER
DEVICE
ti 4
311
EROSION AND SEDIMENT CONTROL PLAN:
1. CLEARING, GRUBBING, AND GRADING OF THE PROPOSED SITE
TO BE LIMITED TO AREAS ADJACENT TO THE PROPOSED HOUSE
AND SEPTIC SYSTEM.
2, DISTURBED AREAS TO BE LOAMED, SEEDED, AND MULCHED,
3. ALL TOPSOIL TO BE STOCKPILED ON SITE AND PROTECTED
WITH HAYBALES OR SILT FENCE.
4. ALL CUT AND FILL SLOPES ARE NOT TO EXCEED 3:1 SLOPES.
5. PRIOR TO SITE DISTURBANCE, THE REPRESENTATIVE OF THE
TOWN OF MONTVILLE SHALL BE NOTIFIED WHEN SEDIMENT
CONTROL MEASURES ARE IN PLACE SO THAT THE INSPECTION
CAN OCCUR.
6, THE CONTRACTOR WILL, BE RESPONSIBLE FOR THE INSTALLATION
AND MAINTENANCE OF ALL REQUIRED SEDIMENT CONTROL
MEASURES THROUGHOUT CONSTRUCTION.
7, DUST CONTROL WILL BE ACCOMPLISHED BY SPRAYING WITH
WATER, AND IF NECESSARY THE APPLICATION OF CALCIUM CHLORIDE.
TEMPORARY VEGETATIVE COVER:
MULCHES APPLICATION RATE
PER 1000 SY,
STRAW/HAY 70-90 lbs.
WOOD CHIPS 185-275 lbs.
PLANTING SCHEDULE:
SEEDING DATES:
APRIL I ------- JUNE 15
AUGUST ------ SEPTEMBER 15
SEED MIXTURE:
450% RED FESCUE
45% KENTUCKY BLUE GRASS
10% PERENNIAL RYE
DESIGN NOTES:
FREE FROM WEEDS
AND COARSE MATTER
FREE OF COARSE MATTER
AIR DRIED, TREAT WITH
12lbs NITROGEN / TON
t' ALI, CONSTRUCTION TO CONFORM TO STANDARDS OF THE CONNECTICUT
PUBLIC HEALTH CODE AND TO THE SATISFACTION OF THE ToAN sANATARI-AN,
2, THIS SYSTEM HAS NOT BEEN DESIGNED FOR THE USE OF LARGE
CAPACITY (-100 GALLONS), DISCHARGE TYPE BATHTUBS. RESIDENTIAL
GARBAGE DISPOSALS ARE NOT ANTICIPATED FOR THIS DESIGN. IN THE
EVENT THAT SUCH AN INSTALLATION IS CONTEMPLATED FOR THE
PROPOSED HOUSE, A LARGER SEPTIC TANK AND INCREASED LEACHING
FIELD CAPACITY WILL BE REQUIRED.
LEACHING SYSTEM CONSTRUCTION NOTES:
1, TOPSOIL TO BE STRIPPED OFF PRIOR TO FILLING, FILL MATERIAL BETWEEN AND BEYOND
TRENCHES 10 BE PERVIOUS, GOOD QUALITY AND CLEAN MEDIUM SAND (SELECT FILL) PLACED
AND COMPACTED IN 6" LIFTS. SELECT FILL SHALL MEET THE FOLLOWING MINIMUM REQUIREMENTS:
A. THE FILL SHALL NOT CONTAIN ANYAlATERikL LARGER THAN 3 INCHES,
B, THE FILL SHALL NOT CONTAIN MORE THAN 45 PERCENT GRAVEL (GRAVEL IS BETWEEN NO, 4 & Y SIEVES)
NO MORE THAN 45 PERCENT OF THE MATERIAL CAN BE RETAINED ON THE NO, 4 SIEVE.
C, THE FILL LESS THE GRAVEL SHALL MEET THE FOLLOWING GRADATION CRITERIA:
SIEVE SIZE: #4 #10 F40 #100 #200
% PASSING:100 70-100 **10-50 0-20 0.5 WET SIEVE
% PASSING: 100 70-100 10-75 0-5 0-2.5 DRY SIBT
PERCENT PASSING THE #40 SIEVE CAN BE INCREASED TO NO GREATER THAN 75% IF THE PERCENT
PASSING THE #100 SIEVE DOES NOT EXCEED 10% AND THE #200 SIEVE DOES NOT EXCEED 5%.
2. DOCUMENTATION OF TEST RESULTS ARE TO BE PROVIDED TO THE HEALTH. DISTRICT.
3. FILL MATERIAL TO BE PLACED PRIOR TO TRENCH EXCAVATION, NO TRAFFIC OTHER THAN
TRACK -DRIVEN EQUIPMENT IS TO CROSS, DUMP, UNLOAD OR OTHERWISE CONTACT THE FILL AREA
AFTER TOPSOIL REMOVAL. FILL MATERIAL TO BE DUMPED AT THE EDGE OF THE STRIPPED AREA AND
SPREAD AND COMPACTED WITH TRACK -DRIVEN VEMCLES, STOCKPILING IS TO TAKE PLACE UPGRADIENT OF
THE LEACHING AREA. THEAREA, DOWN GRADIENT OF THE LEACHING AREA IS NOT TO BE DISTURBED.
SEPTIC SYSTEM CONSTRUCTION NOTES:
1. CONSTRUCTION SEUTNqE_;
A. STRIP & STOCKPILE TOPSOIL FROM: LEACHING TRENCH AREA.
B, PLACE SELECT FILL TO 6" BELOAT EXISTING GRADE.
C. AFTER FILL IS PLACED AND CONTACTED A PERC TEST IS TO BE PERFORMED.
D, A PER TEST IS TO BE PERFORMED IN THE RESERVE AREA,
E. CONSTRUCT LEACHING TRENCHES TO DESIGN LINE & GRADE,
F. LOAM, FINE GRADE TO FINISHED GRADE AND SEED, PROTECT DISTURBED AREAS
INITH EROSION CONTROLS UNTIL FIRST MOINING.
2. THE PIPE BETWEEN THE HOUSE AND SEPTIC TANK SHALL BE 4 IN. EXTRA HEAVY CAST IRON,
DUCTILE IRON OR EXTRA STRENGTH PVC ASTM D1.785 SCHD 40 OR APPROVED EQUAL.
3. ALL DISTRIBUTION PIPE IS TO BE ASTM D3034 SDR 35 (4"PVC) OR APPROVED EQUAL UNLESS NOTED.
4, SEPTIC TANK SHALL BE SET LEVEL ON A MINIMUM OF 6" OF PROCESSED GRAVEL, OR BROKEN
STONE ON COMPACTED SUBGRADE.
5. THERE ARE NO APPARENT WELLS OR SEPTIC FIELDS WITHIN 75" OF THE PROPOSED NVELL AND
SEPTIC SYSTEM AS SHOWN ON THIS PLAN.
6. APPROVED STONE, AGGREGATE FOR LEACHING TRENCHES SHALL BROKEN STONE, CRUSHED
STONE, OR SCREENED GRAVEL MEETING CT DOT FORM 814A SPECIFICATION FOR M.0 1.0 1 FOR NO. 4
STONE: STEVE SIZE PERCENT PASSING
,
- _P.Y--_ NVEIGHT)
2 -INCH 100
1 -1/2 -INCH 90-100
1 -INCH 20-55
3/4 -INCH 0-15
3/8 -INCH 0-5
#40 0-3
#200 0-1.5
7. THE LOCATION AND ELEVATION OF THE PROPOSED SEPTIC SYSTEM AND HOUSE SHALL BE STAKED
IN THE FIELD BY A LICENSED LAND SURVEYOR.
8. THE BOTTOM OF THE LEACHING TRENCHES ARE NOT TO EXCEED 6" INTO EXISTING GRADE.
1. TOPOGRAPHIC INFORMATION ON THIS PLAN COMPLIES WITH T-2 MAPPING
STANDARDS,
2, PROPOSED HOUSE AND SEPTIC SYSTEM TO BE STAKED IN THE FIELD BY
A LAND SURVEYOR LICENSED IN THE STATE OF CONNECTICUT
3. BASE FOR LEVELS: PER REFERENCE NIAP.
4. PROPERTY IS LOCATED IN THE TOWN OF MONTVILLE ZONING DISTRICT R-80.
5. THERE .ARE NO'%TELLS LOCATED WITHIN '175'OF THE PROPOSED SEPTIC SYSTEM
LOCATED ON ABUTTING PROPERTIES.
6, A BENCHMARK IS TO BE PLACED WITHIN 50" OF THE PROPOSED HOUSE &
SEPTIC SYSTEM AT THE TIME OF CONSTRUCTION,
9. IF BLASTING IS NECESSARY A PRE -BLAST SURVEY SHALL BE REQUIRED
PRIOR TO THE, START OF CONSTRUCTION,
REFERENCE MAP:
SUBDIVISION PLAN PREPARED FOR ELIZABETH PATRICIA SHEEHAN
MASSAPEAG ROAD, MONTVILLE, CONNECTICUT, SCALES AS NOTED
REVISED TO 12/27/07, PREPARED BY CME ASSOCIATES, INC,