HomeMy WebLinkAboutmap794" TOP COURSE - ROLLED BANK RUN GRAVEL
CONFORMING TO CT DOT FORM 816 M.02.03
AND M.02.06 GRADATION "C" OR COMPACTED
1-114" PROCESSED TRAPROCK MIX
40 - 4
d
D ) d
a
y a `-'-'4
a
V Q
a a a
rrte 0
0 0c6" BINDER COURSE - ROLLED BANK 0
L 0 RUN GRAVEL CONFORMING TO CT >
0 DOT FORM 816 M.02.03 AND 0 COMPACTED SUITABLE00M.02.06 GRADATION "A" , c SUBGRADE
TRAFFIC BOUND GRAVEL SURFACE
NOT TO SCALE
2-112- BIT CONC.
PAVEMENT ('MIN.)
SUITABLE
COMPACTED
SUBGRADE 6" PROCESSED
GRAVEL (MIN.)
SECTION VIEW
t
NOT TO SCALE
10' TO TOP OF 48" PROPOSED GRADE,
EMBANKMENT -- - GRADE TO PREVENT
PONDING
iT
6" BACKFILL (MIN) I
I _ i i NON -WOVEN
H FABRIC FILTER
2,. --- ---
STONE AGGREGATEAPPROVEDFILLASMIN. I II 6" MfN I APPROVEDTREQUIRED (SEE GENERAL. _ _ _ _ (SEE GENERAL NOTEE #7)
NOTES' #6 AND J10) 18" MIN. TO GROUNDWATER
4" PERE OR MOTTLING
PVC
48" MIN. TO LEDGE
12" 8" STONE LEACHING TRENCH
NOT TO SCALE
MINIMUM 17" ---,
DIAMETER MANHOLE
GASKETED)
INLET --
INLET --
BAFFLE
213--,
REQUIRED
CAPACITY
1,500 GALLON----_.,
SEPTIC TANK
ORIGINAL GRADE W/
TOPSOIL REMOVED
MAINTAIN 1h n LIP AT
EDGE OF PAVEMENT
cz SEE SECTION VIEW
BITUMINOUS
CONCRETE8' 8' RADIUS
TYPICAL DRIVEWAY APRuo N
NOT TO SCALE
FILTER FENCE
COMPACTED
BACKFILL
EXCAVATE XK
T ENCHWR F.p I. G FLOW
OF PUBLIC HEALTH. HAVE BEEN INSTALLED AS THE SEQUENCE OF CONSTRUCTION NECESSITATES.
EXISTING GRADE
CL.
o!.
C> V
PVC ASTM D 1785/ASTM D 2665 OR APPROVED EQUAL AS INDICATED /N TABLE N0. 2 OF
2018 BOUNDARIES LLC
rn
U 12 MIN.
PREPARED FOR THE OWNER OF THIS PROJECT, AT THIS SITE, AND IS NOT TO BE
4 DEPTH UNDISTURBED
ti
GROUND
SUITABLE VEGETATION. THE USE OF TEMPORARY FILL AND/OR EXCAVATION SHALL BE MINIMIZED TO3.
ton
SEDIMENT FENCE DETAIL
SEPTIC SYSTEM, THERE ARE NO SEPTIC SYSTEMS WITHIN 75' OF THE PROPOSED WELL.
in
NOT TO SCALE
THERE SHALL BE NO STUMPS BURIED ON-SITE OR BOULDERS BURIED WITHIN 50' DOWN GRADIENT DUMPING OF OIL OR OTHER DELETERIOUS MATERIALS ON THE GROUND IS FORBIDDEN. THE
Ln
OF THE SEPTIC SYSTEM, SHOULD ANY SIGNIFICANT VARIATIONS FROM THE TEST HOLE DATA BE DEVELOPER OR CONTRACTOR SHALL PROVIDE A MEANS OF CATCHING, RETAINING AND PROPERLYENCOUNTEREDDURINGEXCAVATIONS (LEDGE, GROUNDWATER, MOTTLING, SOIL TYPE, ETC.), THE
r- PACKK STRAW BETWEEN BALES 2" X 2" X 36"
STRAW BALE HARD WOOD STAKE
2 PER BALE)
V
i! II li it
I 1 COMPACTED
BACKFILL 1 1
Il !i II I it FLOW II
I- -I-- -- - J 12'" MIN. r E
L " 4 MINQ0
NOT.
1. USE SINGLE OR DOUBLE BALE HEIGHT AS REQUIRED.
STAKED HAY BALE BARRIERQ
4" MIN.
OUTLET
OUTLET F7LTER
DEVICE
LENGTH NOT GREATER THAN 4 TIMES WIDTH OR DEPTH
a
r
MANN mmmm
10, -
5p
TOP OF EMBANKMENT
r
TYPICAL SLOPES SHALL NOT
EXCEED 507 (2H:1 V)
SELECT FILL--' ORIGINAL GRADE
y
4' MINIMUM 18 MINIMUM LEACHING MEDIA
COMMON FILL
MAX. GROUNDWATER
ELEVATION
LEDGE RO' NOTE. REFERENCE FIGURE 13 OF THECTECHNICALSTANDARDSFORSUBSURFACE
SEWAGE DISPOSAL SYSTEMS" (JAN. 1, 2018)
TYPICAL LEACHFIELD IN FILL CROSS SECTION
NOT TO SCALE
COMPACTED
GRAVEL FILL
MIRAFI 140N GEOTEX77LE
OR APPROVED EQUAL
COMPACTED SUBGRADE
NOTE:
1. TO BE USED AT PIPE INLETS AND DISCHARGES.
TYPICAL MODIFIED RIP RAP SECTION
W00!
STAKED HAYBALE
NOT TO SCALE
NOT TO SCALE
OMPACTED
3ACKFILL
v G
tr-
rdif
PLA
d 2-1/4"
W5- 0
12r
t2-112-
NOTE. USE 4HDBOX BY SECTIO
JOLLEY PRECAST,
INC. OR APPROVED
EQUAL
j D-130 DETAIL
NOT TO SCALE
FINISHED GRADE
THREADED 4" PVC END CAP WITH PLUG
A
SANITARY CLEANOUT DETAIL
NOTTO SCALE
NOT TO SCALE
12" 6' --
MIN
12"
24"
SANITARY
1. THIS SEPTIC SYSTEM INSTALLATION INCLUDING ALL MATERIALS (PIPING, SEPTIC TANK, STONE, FILL,
ETC.) USED FOR THIS SEPTIC SYSTEM SHALL CONFORM TO THE CURRENT EDITION%REVISION OF
THE 'TECHNICAL STANDARDS FOR SUBSURFACE SEWAGE DISPOSAL SYSTEMS" REVISED JANUARY
fil, 0
s0066
NOT TO SCALE
w
OF PUBLIC HEALTH. HAVE BEEN INSTALLED AS THE SEQUENCE OF CONSTRUCTION NECESSITATES. 2. THE PROPOSED HOUSE SEWER FROM THE BUILDING TO THE SEPTIC TANK SHALL BE SCHEDULE 40
o!.
C> V
PVC ASTM D 1785/ASTM D 2665 OR APPROVED EQUAL AS INDICATED /N TABLE N0. 2 OF
2018 BOUNDARIES LLC
rn THIS DRAWING IS THE PROPERTY OF BOUNDARIES LLCAND HAS BEENSPECIFICALLY
g PREPARED FOR THE OWNER OF THIS PROJECT, AT THIS SITE, AND IS NOT TO BE
FOR THIS SEPTIC SYSTEM SHALL BE 4" PVC ASTM D3034, SDR 35 WITH RUBBER COMPRESSION
DUPLICATED OR USED IN PARTOR WHOLEFORANY OTHER PURPOSE, PROJECT, LOCATION
ti
OR OWNER WITHOUT THE EXPRESSED WRITTEN CONSENTOFBOUNDARIES LLC.
SUITABLE VEGETATION. THE USE OF TEMPORARY FILL AND/OR EXCAVATION SHALL BE MINIMIZED TO3.
4" MIN.
OUTLET
OUTLET F7LTER
DEVICE
LENGTH NOT GREATER THAN 4 TIMES WIDTH OR DEPTH
a
r
MANN mmmm
10, -
5p
TOP OF EMBANKMENT
r
TYPICAL SLOPES SHALL NOT
EXCEED 507 (2H:1 V)
SELECT FILL--' ORIGINAL GRADE
y
4' MINIMUM 18 MINIMUM LEACHING MEDIA
COMMON FILL
MAX. GROUNDWATER
ELEVATION
LEDGE RO' NOTE. REFERENCE FIGURE 13 OF THECTECHNICALSTANDARDSFORSUBSURFACE
SEWAGE DISPOSAL SYSTEMS" (JAN. 1, 2018)
TYPICAL LEACHFIELD IN FILL CROSS SECTION
NOT TO SCALE
COMPACTED
GRAVEL FILL
MIRAFI 140N GEOTEX77LE
OR APPROVED EQUAL
COMPACTED SUBGRADE
NOTE:
1. TO BE USED AT PIPE INLETS AND DISCHARGES.
TYPICAL MODIFIED RIP RAP SECTION
W00!
STAKED HAYBALE
NOT TO SCALE
NOT TO SCALE
OMPACTED
3ACKFILL
v G
tr-
rdif
PLA
d 2-1/4"
W5- 0
12r
t2-112-
NOTE. USE 4HDBOX BY SECTIO
JOLLEY PRECAST,
INC. OR APPROVED
EQUAL
j D-130 DETAIL
NOT TO SCALE
FINISHED GRADE
THREADED 4" PVC END CAP WITH PLUG
A
SANITARY CLEANOUT DETAIL
NOTTO SCALE
NOT TO SCALE
12" 6' --
MIN
12"
24"
SANITARY
1. THIS SEPTIC SYSTEM INSTALLATION INCLUDING ALL MATERIALS (PIPING, SEPTIC TANK, STONE, FILL,
ETC.) USED FOR THIS SEPTIC SYSTEM SHALL CONFORM TO THE CURRENT EDITION%REVISION OF
THE 'TECHNICAL STANDARDS FOR SUBSURFACE SEWAGE DISPOSAL SYSTEMS" REVISED JANUARY
fil, 0
s0066
ANCHOR WITH TWO 2X2 x3'
STAKES EACH BALE
0"
mo
ul
0:
cls
fj° c
r 12 /\
2'
A
2H:1 V
FILTER FABRIC LINER
6" LOAM & SEED (MIN)
NOTE. ELEVATIONS VAR! ; SE D 4N FOR ACTUAL ELEVATIONS
GRASS SWALE DETAIL
PIPE OUTLETS WITH
FLARED END SECTIONS
15 " HDPE)
NOT TO SCALE
15'
13.5'
NOTES:
1. DIMENSIONS REPRESENT MINIMUM VALUES. a
2. APRON DESIGN BASED ON 2000 CT DOT DRAINAGE MANUAL.
v _
RIPRAP SPREAD APRON DETAIL
NOT TO SCALE J,
JEFFREY
THE CONTRACTOR SHALL APPOINT AN AGENT WHO SHALL BE PERSONALLY RESPONSIBLE FOR
IMPLEMENTING THIS EROSION AND SEDIMENT CONTROL PLAN AND ENFORCING THE PRESCRIBED
SAFEGUARDS DURING THE CONSTRUCTION PERIOD.
SUPPORT DEWATERING THIS RESPONSIBILITY INCLUDES THE INSTALLATION AND MAINTENANCE OF CONTROL MEASURES
HOSE ON HAY BALE THROUGHOUT THE CONSTRUCTION PERIOD, INFORMING ALL PARTIES ENGAGED ON THE CONSTRUCTION
SITE OF THE REQUIREMENTS AND OBJECTIVES OF THE PLAN, NOTIFYING THE PROPER TOWN AGENCIES
AND OFFICIALS OF ANY TRANSFER OF THIS RESPONSIBILITY, AND CONVEYING A COPY OF THE
APPROVED EROSION AND SEDIMENT CONTROL PLAN IF THE TITLE OF THE LAND IS TRANSFERRED TO A
ti DISCHARGE HOSE THIRD PARTY
FROM DEWATERING
f PUMP
EROSION CONTROL NOTES
f f STAKED HAY BALE
o, BARRIER (TYP) 1 ALL UTILITIES ARE APPROXIMATE CONTRACTOR TO VERIFY ALL UTILITIES PRIOR TO CONSTRUCTION
z , ; 1st `i \ -1 , "LINE BOTTOM OF 15'x 15'x4' DEEP
15 DEWATERING BASIN WITH MODIFIED
RIP RAP OVER AN APPROVED
FILTER FABRIC
DE ATERIN S L
NOT TO SCALE
CONTACT 'CALL -BEFORE -YOU -DIG" AT 1-800-922-4455 AT LEAST 48 HOURS PRIOR TO ANY
EXCAVATION.
2. THE ,RESPONSIBLE PARTY FOR THE INSTALLATION AND MAINTENANCE OF ALL EROSION CONTROL
MEASURES IS THE SITE CONTRACTOR, WHICH IS TO BE DETERMINED.
J. THE 72002 CONNECTICUT GUIDELINES FOR SOIL EROSION AND SEDIMENT CONTROL" BY THE CONNECTICUT
COUNCIL ON SOIL AND WATER CONSERVATION IN COOPERATION WITH THE CONNECTICUT DEPARTMENT OF
ENVIRONMENTAL PROTECTION, CT DEEP BULLETIN 34, SHALL BE USED FOR INSTALLING AND MAINTAINING
ALL EROSION CONTROL MEASURES. THE PROPERTY OWNER SHALL INSTALL ADDITIONAL MEASURES AS
NECESSARY IF DIRECTED BY THE ENGINEER OR TOWN STAFF.
4. SEEDING FOR PERMANENT STABILIZATION SHALL BE COMPLETED BETWEEN APRIL 15 THROUGH JUNE 15
OR BETWEEN AUGUST 15 THROUGH SEPTEMBER 15. IF SEEDING CANNOT BE COMPLETED WITHIN THESE
TIMES, APPLICATION OF TEMPORARY MULCH WILL BE CONDUCTED UN77L THE NEXT SEEDING PERIOD.
SEED MIXTURE SHALL BE AS FOLLOWS.
KENTUCKY BLUEGRASS 20 LBS/ACRE OR 0.45 LBS/1,000 S.F.
CREEPING RED FESCUE 20 LBS/ACRE OR 0.45 LBS/1,000 S.F.
PERENNIAL RYEGRASS 5 LBS/ACRE OR 0.10 LBS/1,000 S.F.
5. MULCH SHALL BE A GOOD QUALITY HAY OR STRAW AND SHALL BE APPLIED AT A RATE OF
APPROXIMATELY 2-3 BALES/1,000 SF.
6. ALL EROSION CONTROL MEASURES SHALL BE INSPECTED WITHIN 24 HOURS AFTER RAIN EVENTS WITH
GREATER THAN 0.5" OF RAINFALL. IN A 24-HOUR PERIOD, AND REPAIRED OR REPLACED AS NECESSARY
TO INSURE COMPLIANCE WITH THE APPROVED SOIL EROSION AND SEDIMENT CONTROL PLAN.
CONSTRUCTION SEQUENCE
1. SECURE ALL NECESSARY LOCAL, STATE AND FEDERAL PERMITS.
2. INSTALL EROSION CONTROLS IN SPECIFIED LOCATIONS AS SHOWN DOWNGRADIENT OF PROPOSED EARTH
WORK. STRIP TOPSOIL FROM DEVELOPMENT AREA AND STOCKPILE AT SPECIFIED LOCATION FOR LATER
REUSE SEED TOPSOIL STOCKPILE WITH RYEGRASS FOR TEMPORARY STABILIZATION.
J. CONSTRUCT DRIVEWAY CROSSING CULVERT, DRIVEWAY AND INSTALL UTILITIES.
4. CONSTRUCT HOUSE, INSTALL SUBSURFACE SEWAGE DISPOSAL SYSTEM, WATER SUPPLY WELL AND
PERFORM SITE GRADING.
5. AT COMPLETION OF CONSTRUCTION, LOAM ALL DISTURBED AREAS (4" MINIMUM), SEED WITH GRASS
AND MULCH. AFTER ALL AREAS HAVE BEEN PERMANENTLY STABILIZED, REMOVE EROSION CONTROL
MEASURES.
NOT TO SCALE
1' LOAD BEARING SHOULDER
TYP BOTH SIDES)
LOAM, SEED & MULCHPROPOSED 14'-'- ,COMPACTED PROCESSED GRAVEL
TYP BOTH SIDES) TBGS DRIVEWAY FROM SPRING LINE
ELEV 232.5± -APPROVED 13ACKFILL
FLARED END UNIT 1 2 _ 2 FLARED END UNIT #2
INV 228.5± 1 -- 1 INV 228,0±
MODIFIED RIPRAP APRON a - - - - - - - - 0 0 o 0cn) 0 0 o MODIFIED RIPRAP SPREADATINLETis;" "nor, fc-,2 nq.L1 /-APRON AT OUTLET
20003
LICENSE NO. DATE NOT TO SCALE
WJ
w
2018 OF THE CONNECTICUT PUBLIC HEALTH CODE BY THE STATE OF CONNECTICUT DEPARTMENT NO CONSTRUCTION SHALL PROCEED UNTIL PROPER SEDIMENTATION AND EROSION CONTROL MEASURESOFPUBLICHEALTH. HAVE BEEN INSTALLED AS THE SEQUENCE OF CONSTRUCTION NECESSITATES. 2. THE PROPOSED HOUSE SEWER FROM THE BUILDING TO THE SEPTIC TANK SHALL BE SCHEDULE 40
w C> V
PVC ASTM D 1785/ASTM D 2665 OR APPROVED EQUAL AS INDICATED /N TABLE N0. 2 OF ALL TEMPORARY FILL, STORAGE OR STOCKPILE AREAS SHALL BE PROPERLY STABILIZED TO PREVENTTECHNICALSTANDARDSFORSUBSURFACESEWAGEDISPOSALSYSTEMS" ALL OTHER SEWER PIPE EROSION AND SUITABLY CONTAINED TO PREVENT TURBID RUNOFF. ALL AREAS AFFECTED BY
FOR THIS SEPTIC SYSTEM SHALL BE 4" PVC ASTM D3034, SDR 35 WITH RUBBER COMPRESSION TEMPORARY FILLS MUST BE RESTORED TO THEIR ORIGINAL CONTOURS, AND REVEGETATED WITH
ti
GASKET OR BELL AND SPIGOT OR APPROVED EQUAL. SUITABLE VEGETATION. THE USE OF TEMPORARY FILL AND/OR EXCAVATION SHALL BE MINIMIZED TO3. THERE ARE NO WELLS (POTABLE, GEOTHERMAL, OR IRRIGATION) WITHIN 75' OF THE PROPOSED ONLY THAT AREA REQUIRED TO PERFORM THE WORK.
SEPTIC SYSTEM, THERE ARE NO SEPTIC SYSTEMS WITHIN 75' OF THE PROPOSED WELL.
in
4. THERE SHALL BE NO STUMPS BURIED ON-SITE OR BOULDERS BURIED WITHIN 50' DOWN GRADIENT DUMPING OF OIL OR OTHER DELETERIOUS MATERIALS ON THE GROUND IS FORBIDDEN. THEOFTHESEPTICSYSTEM, SHOULD ANY SIGNIFICANT VARIATIONS FROM THE TEST HOLE DATA BE DEVELOPER OR CONTRACTOR SHALL PROVIDE A MEANS OF CATCHING, RETAINING AND PROPERLYENCOUNTEREDDURINGEXCAVATIONS (LEDGE, GROUNDWATER, MOTTLING, SOIL TYPE, ETC.), THE DISPOSING OF DRAINED OIL, REMOVED OIL FILTERS OR OTHER DELETERIOUS MATERIAL FROM
Lw
DESIGN ENGINEER SHALL BE NOTIFIED PRIOR TO INSTALLATION OF THE SEPTIC SYSTEM. EQUIPMENT USED ON-SITE. VEHICLE MAINTENANCE SHALL BE COMPLETED OFF-SITE ALL OIL5. ALL EXISTING UTILITIES ARE APPROXIMATE ONLY. THE CONTRACTOR SHALL VERIFY ALL UTILITY SPILLS SHALL BE IMMEDIATELY REPORTED TO THE DEPARTMENT OF ENERGY AND ENVIRONMENTALLOCATIONSANDELEVATIONSPRIORTOANYCONSTRUCTION. CONTRACTOR SHALL CONTACT
CALL -BEFORE -YOU -DIG" AT 1-800-922-4455 AT LEAST 48 HOURS PRIOR TO ANY EXCAVATION. PROTECTIONfHAZARDOUS MATERIALS OFFICE FAILURE TO DO SO MAY RESULT IN THE IMPOSITION OF
6. IF REQUIRED, THE PROPOSED FILL FOR THIS SEPTIC SYSTEM SHALL MEET THE FOLLOWING FINES UNDER THE APPLICABLE CONNECTICUT GENERAL STATUTES.
SPECIFICATIONS:
A. OF FILL SHALL PASS THROUGH A 3" STEVE EVERY PRECAUTION SHALL BE TAKEN DURING CONSTRUCTION TO PREVENT AND MINIMIZE THE
B. MAXIAXMUM 9 OF GRAVEL (BETWEEN #4 & 3" STEVE) = 459. DEGRADATION OF THE EXISTING WATER QUALITY, ALL ACTIVITIES SHALL BE IN CONFORMANCE TO AND
C. GRADATION OF FELL WITHOUT THE GRAVEL SHALL MEET THE FOLLOWING CRITERIA: CONSISTENT WITH ALL APPLICABLE WATER QUALITY STANDARDS AND MANAGEMENT PRACTICES AS SET
SIEVE SIZE 7 PASSING (MET) % PASSIttlG {DRY) FORTH BY LOCAL, STATE AND FEDERAL AGENCIES.
4 100% 100%
10 70 100% 70 - 1009 DURING THE PERIOD OF CONSTRUCTION, THE CONTRACTOR IS RESPONSIBLE FOR ALL EROSION AND
40 10 - 509* 10 - 757 SEDIMENT CONTROL MEASURES. SAID MEASURES SHALL BE INSPECTED WEEKLY AND AFTER EACH
100 0 - 207 0 - 57 RAINSTORM. ACCUMULATED DEPOSITS OF SEDIMENT AND SILT SHALL BE PERIODICALLY REMOVED
1200 0 - 57 0 - 2.57 FROM THE UPSTREAM SIDE OF THE EROSION AND SEDIMENT CONTROL BARRIERS, AND UPON
D. * PERCENT PASSING THE #40 WET SIEVE CAN BE INCREASED TO NO GREATER THAN 757 IF ESTABLISHMENT OF PERMANENT VEGETATIVE COVER. SUCH MATERIALS REMOVED SHALL BE SPREAD
E
AND STABILIZED IN NON -WETLAND AREAS WHICH ARE NOT SUBJECT TO EROSION, OR WHICH ARE NOTTHEPERCENTPASSINGTHE #100 SIEVE DOES NOT EXCEED 107 AND THE #200 SIEVE TO BE PAVED DR BUILT UPON. DOES NOT EXCEED 57.
Q) 4-
E. PERCOLATION RATE AFTER PLACEMENT AND COMPACTION SHALL BE FASTER THAN OR EQUAL WOOD CHIP BERMS, SEDIMENT FENCE AND OTHER EROSION AND SEDIMENT CONTROL MEASURES SHALL.
co
TO 10.0 MINUTESIINCH.
A WET OR DRY SIEVE ANALYSIS MAY BE REQUIRED PRIOR TO FILL PLACEMENT TO VERIFY THAT IT BE REPAIRED, CLEANED ANDIOR REPLACED AS NECESSARY THROUGHOUT THE CONSTRUCTION PERIOD
MEETS THESE SPECIFICATIONS. THE FILL SHALL BE APPROVED BY THE LOCAL HEALTH IN ORDER TO MAINTAIN COMPLETE AND INTEGRAL EROSION AND SEDIMENT CONTROL PROTECTION.
DISTRICT/DEPARTMENT OR DESIGN ENGINEER PRIOR TO ITS PLACEMENT ON SITE: ONCE IN PLACE, ALL EROSION AND SEDIMENT CONTROL FACILITIES AND MEASURES ARE TO REMAIN IN
7. APPROVED STONE AGGREGATE MEANS CRUSHED OR BROKEN STONE, OR CRUSHED AND UNCRUSHED PLACE AND IN PROPER CONDITION AND BE CONTINUOUSLY MAINTAINED UNTIL FINAL GRADING HAS
GRAVEL MEETING THE GRADATION FOR NO. 4 (1y4" STONE) OR NO. 6 (3i';" STONE) AGGREGATE PER BEEN COMPLETED, ALL DISTURBED AREAS UPGRADIENT OF SAID FACILITIES HAVE BEEN PERMANENTLY
DEPARTMENT OF TRANSPORTATION FORM 816 SPECIFICATION M.01.01 (OR LATEST SPECIFICATION), STABILIZED, AND ALL NEWLY GRASSED AREAS HAVE HAD AT LEAST TWO MOWINGS. FOLLOWING SUCH
AND THE 140 AND #200 SIEVE GRADATION STIPULATED IN SECTION M A, BASED ON A WET SIEVE PERMANENT STABILIZATION, THE FACILITIES SHALL BE DISMANTLED, REMOVED, AND DISPOSED OF IN AN
O
ANALYSIS. STONE AGGREGATE SHALL BE FREE OF SILT, DIRT OR DEBRIS, AND SHALL SHOW A APPROVED MANNER. ADDITIONAL EROSION AND SEDIMENT CONTROL MEASURES BEYOND THOSE
LOSS OF ABRASION OF NOT MORE THAN 509 USING AASHTO METHOD T-96, AND WHEN TESTED SHOWN ON THE PLANS OR PRESCRIBED HEREIN SHALL BE PUT IN PLACE, WHENEVER NECESSARY, TO
FOR SOUNDNESS USING AASHTO METHOD T-104 NOT HAVE A LOSS OF MORE THAN 159 AT THE ADDRESS FIELD CONDITIONS ANDIOR AS ORDERED BY TOWN STAFF OR THEIR DESIGNATED AGENT
END OF 5 CYCLES.
NO. 4 AGGREGATE NO. 6 AGGREGATE* DISTURBANCE OF THE LAND SHALL BE LIMITED TO THE MINIMUM EXTENT NECESSARY TO COMPLETE
SIEVE SIZE 9 PASSING 7 PASSING THE PROPOSED DEVELOPMENT ALL EXISTING TREES AND SHRUBS SHALL BE CONSERVED WHERE
2 INCH 1007 NIA POSSIBLE, EXCEPT THOSE WHOSE REMOVAL IS REQUIRED TO PERFORM THE PROPOSED WORK. THE
1.5 INCH 90 - 1007 NIA LIMITS OF DISTURBANCE SHALL BE ESTABLISHED IN THE FIELD PRIOR TO STARTING ANY ACTUAL
1 INCH 20 - 557 1007 CONSTRUCTION ACTIVITIES AND SHALL BE GENERALLY AS DEPICTED ON THIS PLAN.
3/4 INCH 0 -- 159 90 - 1009
E
1/2 INCH NIA 20 - 559 THE CONTRACTOR SHALL BE RESPONSIBLE TO INSPECT THE SITE IN ACCORDANCE WITH THE
318 INCH 0 - 57 0 - 159 PROCEDURES AS OUTLINED IN THE "GENERAL PERMIT FOR THE DISCHARGE OF STORMWATER AND
4 NIA 0 - 5Z DEWATERING WASTEWATERS FROM CONSTRUCTION ACTIVITIES" AS ADOPTED BY THE DEPARTMENT OF
140 0 - 37 0 - 39 ENERGY AND ENVIRONMENTAL PROTECTION, EFFECTIVE ON OCTOBER 1, 2013.
200 0 - 1.59 0 -a 1.57
NO. 6 AGGREGATE IS ONLY APPROVED TO BE USED FOR LEACHING TRENCHES AND PROPRIETARY THE CONTRACTOR SHALL INSPECT ALL DISTURBED AREAS OF CONSTRUCTION ACTIVITY THAT HAVE NOT
SYSTEMS ONLY. BEEN FINALLY STABILIZED, STRUCTURAL CONTROL MEASURES, AND LOCATIONS WHERE VEHICLES ENTER
8. NO DEVIATION FROM THE APPROVED DESIGN PLAN SHALL BE ALLOWED WITHOUT PRIOR WRITTEN OR EXIT THE SITE AT LEAST ONCE EVERY SEVEN CALENDAR DAYS AND WITHIN 24 HOURS OF THE END
APPROVAL FROM THE LOCAL HEALTH DISTRICTIDEPARTMENT AND THE DESIGN ENGINEER, OF ALL RAIN EVENTS. WHERE SITES HAVE BEEN TEMPORARILY OR FINALLY STABILIZED, SUCH
9. THE SEPTIC TANK SHALL BE PRECAST CONCRETE UNLESS OTHERWISE AUTHORIZED BY THE DESIGN INSPECTION SHALL BE CONDUCTED AT LEAST ONCE EVERY MONTH FOR THREE CONSECUTIVE MONTHS.
ENGINEER.
10. SITE PREPARATION PROCEDURE FOR THE INSTALLATION OF THE PROPOSED SEPTIC SYSTEM: DURING CONSTRUCTION AND IMMEDIATELY FOLLOWING CONSTRUCTION, THE CONTRACTOR SHALL BE
A. STRIP ALL TOPSOIL.., VEGETATION AND ORGANIC MATERIAL IN THE AREA OF, AND 5' SURROUNDING, RESPONSIBLE FOR SITE INSPECTION AND MAINTENANCE TO ASSURE PROPER PERFORMANCE OF THETHEPRIMARYLEACHINGGALLERIES. SEDIMENTATION AND EROSION CONTROL SYSTEM. INSPECTING AND MAINTAINING SHALL INCLUDE, AT AB. EXCAVATE TO DESIGN ELEVATION PER PLAN. USING A HEAVY RAKE OR EQUAL, THOROUGHLY MINIMUM THE FOLLOWING: SCARIFY AND ROUGHEN UP THE EXPOSED SUBSOIL. PREVENT ANY VEHICULAR TRAFFIC, BACKHOE, INSPECTION OF ALL SEDIMENT FENCE, WOOD CHIP BERMS AND STAKED HAY BALES, REMOVETRUCKS, ETC. FROM SMOOTHING/COMPACTING THIS EXPOSED SUBSOIL. ACCUMULATED SEDIMENT IF REQUIRED (GREATER THAN 4" DEPTH). C. INSTALL SEPTIC SYSTEM PER PLAN USING APPROVED STONE AGGREGATE AS INDICATED IN NOTE
7. INSPECTION OF ANTI -TRACKING PAD, REMOVE, DISPOSE AND REPLACE IF PAD IS NO LONGER
D. COVER SYSTEM WITH APPROVED FILTER FABRIC AND A MINIMUM OF 6" OF LOAM IN LAWN AREAS. FUNCT/ONAL IN THE CATCHMENT OF SEDIMENTS FROM VEHICULAR/`TRUCK TRAFFIC.
GRADE TO PREVENT PONDING AND SEED WITH GRASS TO STABILIZE THE FINISHED GRADE 10' INSPECTION OF ALL DRIVEWAY AREAS AFTER PLACEMENT OF TRAFFIC BOUND GRAVEL SURFACE,
FROM ANY PART OF THE PROPOSED LEACHING TRENCHES SHALL BE AT LEAST THE SAME REMOVE ACCUMULATED SEDIMENT AND ANY LITTER DEBRIS.
ELEVATION AS THE TOP OF THE RESPECTIVE LEACHING TRENCH.
E. ACCESS MANHOLES AT THE INLET BAFFLE AND AT THE OUTLET FILTER OF THE SEPTIC TANK DISTURBED AREAS AND AREAS USED FOR STORAGE OF MATERIALS THAT ARE EXPOSED TO
SHALL BE INSTALLED TO WITHIN 12 OF FINISHED GRADE PRECIPITATION SHALL BE INSPECTED FOR EVIDENCE OF, OR THE POTENTIAL FOR, POLLUTANTS
11. FOR EXACT HOUSE AND GARAGE DIMENSIONS, SEE BUILDING PLANS. ENTERING THE DRAINAGE SYSTEM. EROSION AND SEDIMENT CONTROL MEASURES IDENTIFIED IN THE
12. BENCHMARK TO BE LOCATED IN THE AREA OF DEVELOPMENT PRIOR TO THE START OF PLAN SHALL BE INSPECTED TO INSURE THAT THEY ARE OPERATING CORRECTLY. DISCHARGE
CONSTRUCTION. LOCATIONS OR POINTS SHALL BE INSPECTED TO ASCERTAIN WHETHER EROSION CONTROL MEASURES
13. PRIOR TO CONSTRUCT+ON, THE HOUSE AND GARAGE, WELL, AND SEPTIC SYSTEM SHALL BE STAKED ARE EFFECTIVE IN PREVENTING SIGNIFICANT IMPACTS TO DOWNSTREAM WATERS. LOCATIONS WHERE
OUT 8Y A LICENSEL LAND SUPIEYC}R. VEHICLES ENTER OR EXIT THE SITE SHALL BE INSPECTED FOR EVIDENCE OF OFF-SITE SEDIMENT
RACKING.
ANCHOR WITH TWO 2X2 x3'
STAKES EACH BALE
0"
mo
ul
0:
cls
fj° c
r 12 /\
2'
A
2H:1 V
FILTER FABRIC LINER
6" LOAM & SEED (MIN)
NOTE. ELEVATIONS VAR! ; SE D 4N FOR ACTUAL ELEVATIONS
GRASS SWALE DETAIL
PIPE OUTLETS WITH
FLARED END SECTIONS
15 " HDPE)
NOT TO SCALE
15'
13.5'
NOTES:
1. DIMENSIONS REPRESENT MINIMUM VALUES. a
2. APRON DESIGN BASED ON 2000 CT DOT DRAINAGE MANUAL.
v _
RIPRAP SPREAD APRON DETAIL
NOT TO SCALE J,
JEFFREY
THE CONTRACTOR SHALL APPOINT AN AGENT WHO SHALL BE PERSONALLY RESPONSIBLE FOR
IMPLEMENTING THIS EROSION AND SEDIMENT CONTROL PLAN AND ENFORCING THE PRESCRIBED
SAFEGUARDS DURING THE CONSTRUCTION PERIOD.
SUPPORT DEWATERING THIS RESPONSIBILITY INCLUDES THE INSTALLATION AND MAINTENANCE OF CONTROL MEASURES
HOSE ON HAY BALE THROUGHOUT THE CONSTRUCTION PERIOD, INFORMING ALL PARTIES ENGAGED ON THE CONSTRUCTION
SITE OF THE REQUIREMENTS AND OBJECTIVES OF THE PLAN, NOTIFYING THE PROPER TOWN AGENCIES
AND OFFICIALS OF ANY TRANSFER OF THIS RESPONSIBILITY, AND CONVEYING A COPY OF THE
APPROVED EROSION AND SEDIMENT CONTROL PLAN IF THE TITLE OF THE LAND IS TRANSFERRED TO A
ti DISCHARGE HOSE THIRD PARTY
FROM DEWATERING
f PUMP
EROSION CONTROL NOTES
f f STAKED HAY BALE
o, BARRIER (TYP) 1 ALL UTILITIES ARE APPROXIMATE CONTRACTOR TO VERIFY ALL UTILITIES PRIOR TO CONSTRUCTION
z , ; 1st `i \ -1 , "LINE BOTTOM OF 15'x 15'x4' DEEP
15 DEWATERING BASIN WITH MODIFIED
RIP RAP OVER AN APPROVED
FILTER FABRIC
DE ATERIN S L
NOT TO SCALE
CONTACT 'CALL -BEFORE -YOU -DIG" AT 1-800-922-4455 AT LEAST 48 HOURS PRIOR TO ANY
EXCAVATION.
2. THE ,RESPONSIBLE PARTY FOR THE INSTALLATION AND MAINTENANCE OF ALL EROSION CONTROL
MEASURES IS THE SITE CONTRACTOR, WHICH IS TO BE DETERMINED.
J. THE 72002 CONNECTICUT GUIDELINES FOR SOIL EROSION AND SEDIMENT CONTROL" BY THE CONNECTICUT
COUNCIL ON SOIL AND WATER CONSERVATION IN COOPERATION WITH THE CONNECTICUT DEPARTMENT OF
ENVIRONMENTAL PROTECTION, CT DEEP BULLETIN 34, SHALL BE USED FOR INSTALLING AND MAINTAINING
ALL EROSION CONTROL MEASURES. THE PROPERTY OWNER SHALL INSTALL ADDITIONAL MEASURES AS
NECESSARY IF DIRECTED BY THE ENGINEER OR TOWN STAFF.
4. SEEDING FOR PERMANENT STABILIZATION SHALL BE COMPLETED BETWEEN APRIL 15 THROUGH JUNE 15
OR BETWEEN AUGUST 15 THROUGH SEPTEMBER 15. IF SEEDING CANNOT BE COMPLETED WITHIN THESE
TIMES, APPLICATION OF TEMPORARY MULCH WILL BE CONDUCTED UN77L THE NEXT SEEDING PERIOD.
SEED MIXTURE SHALL BE AS FOLLOWS.
KENTUCKY BLUEGRASS 20 LBS/ACRE OR 0.45 LBS/1,000 S.F.
CREEPING RED FESCUE 20 LBS/ACRE OR 0.45 LBS/1,000 S.F.
PERENNIAL RYEGRASS 5 LBS/ACRE OR 0.10 LBS/1,000 S.F.
5. MULCH SHALL BE A GOOD QUALITY HAY OR STRAW AND SHALL BE APPLIED AT A RATE OF
APPROXIMATELY 2-3 BALES/1,000 SF.
6. ALL EROSION CONTROL MEASURES SHALL BE INSPECTED WITHIN 24 HOURS AFTER RAIN EVENTS WITH
GREATER THAN 0.5" OF RAINFALL. IN A 24-HOUR PERIOD, AND REPAIRED OR REPLACED AS NECESSARY
TO INSURE COMPLIANCE WITH THE APPROVED SOIL EROSION AND SEDIMENT CONTROL PLAN.
CONSTRUCTION SEQUENCE
1. SECURE ALL NECESSARY LOCAL, STATE AND FEDERAL PERMITS.
2. INSTALL EROSION CONTROLS IN SPECIFIED LOCATIONS AS SHOWN DOWNGRADIENT OF PROPOSED EARTH
WORK. STRIP TOPSOIL FROM DEVELOPMENT AREA AND STOCKPILE AT SPECIFIED LOCATION FOR LATER
REUSE SEED TOPSOIL STOCKPILE WITH RYEGRASS FOR TEMPORARY STABILIZATION.
J. CONSTRUCT DRIVEWAY CROSSING CULVERT, DRIVEWAY AND INSTALL UTILITIES.
4. CONSTRUCT HOUSE, INSTALL SUBSURFACE SEWAGE DISPOSAL SYSTEM, WATER SUPPLY WELL AND
PERFORM SITE GRADING.
5. AT COMPLETION OF CONSTRUCTION, LOAM ALL DISTURBED AREAS (4" MINIMUM), SEED WITH GRASS
AND MULCH. AFTER ALL AREAS HAVE BEEN PERMANENTLY STABILIZED, REMOVE EROSION CONTROL
MEASURES.
NOT TO SCALE
1' LOAD BEARING SHOULDER
TYP BOTH SIDES)
LOAM, SEED & MULCHPROPOSED 14'-'- ,COMPACTED PROCESSED GRAVEL
TYP BOTH SIDES) T BGS DRIVEWAY FROM SPRING LINE
ELEV 232.5± -APPROVED 13ACKFILL
FLARED END UNIT 1 2 _ 2 FLARED END UNIT #2
INV 228.5± 1 -- 1 INV 228,0±
MODIFIED RIPRAP APRON a - - - - - - - - 0 0 o 0cn) 0 0 o MODIFIED RIPRAP SPREADATINLETis;" "nor, fc-,2 nq.L1 /-APRON AT OUTLET
20003
LICENSE NO. DATE NOT TO SCALE
WJ
w
a
Lo
n C
w C> V
N
Jti
J i 0
vs 4? -p
in Ca
co c5
t
V
Lw
rtz
MLu
4-J
6.
o,co
u
r. I-
SHEET NO.
2
cu
V
4-J
6. V
a E
A*"%k
Q) 4-
co D
L.
C6
O
O
E O
SHEET NO.
2