Loading...
HomeMy WebLinkAboutPlanSPIK (FNE "ROPOSED RIGHT OF WAY I FILTER I FABRIC ANGLE 10' UP SLOPE FOR STABILITY AND POST SELF CLEANING ,goo COMPACTED N o BACKFILL SILT FENCE NOT TO SCALE 2X2 5/8 16 GA. WIRE MESH 1 1/2 " /2" /n d —-Ais_.: r EROSION AND SEDIMENT CONTROL PLAN 1.) CLEARING, GRUBBING, AND GRADING OF THE PROPOSED LOT TO BE LIMITED TO AREAS ADJACENT TO THE PROPOSED HOUSE, DRIVEWAY, AND SEPTIC SYSTEM. 2.) DISTURBED AREAS TO BE LOAMED, SEEDED, AND MULCHED, 3.) ALL TOPSOIL TO BE STOCKPILED ON SITE AND PROTECTED WITH HAYBALES OR SILT FENCE. 4.) ALL CUT AND FILL SLOPES ARE NOT TO EXCEED 3:1 SLOPES. 5.) PRIOR TO SITE DISTURBANCE, THE REPRESENTATIVE OF THE TOWN OF MONTVILLE SHALL BE NOTIFIED WHEN SEDIMENT CONTROL MEASURES ARE IN PLACE SO THAT THE INSPECTION CAN OCCUR. 6.) THE DEVELOPER WILL BE RESPONSIBLE FOR THE INSTALLATION AND MAINTENANCE OF ALL REQUIRED SEDIMENT CONTROL MEASURES THROUGHOUT CONSTRUCTION. 7.) DUST CONTROL WILL BE ACCOMPLISHED BY SPRAYING WITH WATER, AND IF NECESSARY THE APPLICATION OF CALCIUM CHLORIDE. TEMPORARY VEGETATIVE COVER PLANTING SCHEDULE MULCHES APPLICATION RATE NOTES SEEDING DATES: PER 1000 S.F. APRIL 1 - JUNE 15 AUGUST 1 - SEPTEMBER 15 STRAW/HAY 70-90 Ibs, FREE FROM WEEDS AND COARSE MATTER SEED MIXTURE: WOOD CHIPS 185-275 Ibs. FREE OF COARSE MATTER 45% RED FESCUE AIR DRIED, TREAT WITH 45% KENTUCKY BLUE GRASS I 121bs NITROGEN / TON 10% PERENNIAL RYE cV r — co ri d- 0 a i, w• r 00 1 . 2" 2"� STANDARD D -60X NOT TO SCALE TESTHOLE DATA PER UNCAS HEALTH DISTRICT - DATED: 04/01/2002 TESTHOLE # 1 0"-2" TOPSOIL 2"-142" MED TO COARSE SAND NO LEDGE, NO WATER, NO MOTTLING TESTHOLE #2 0"-4" TOPSOIL 4"-100" MED TO COARSE SAND NO LEDGE, NO WATER, NO MOTTLING 160.11TESTHOLE 13 0"-18" TOPSOIL #3 18"-52" SUBSOIL 52"-83" SAND AND GRAVEL / LIFTING HANDLES NO LEDGE, NO WATER, NO MOTTLING PROPOSED ' r SPIKE WELL �, p0 0�` ' FND. r' o r ' 12" OF BACKFILL 1' BROKEN STONE ( ,F\��\��\�' TESTHOLE #4 PRO TP % % r' \ \ \ \/\/\/\/\/ /\� 0 „-13" TOPSOIL // \/\/\/\/ \/ S• t i I' , j\\/\\/\\/\/\/\/\ \/\/\ \/ 13"-37" SANDY SUBSOIL S ; / r 4 / / /', / / / / / / / A4o'/ \\�K\\�\,�\\ \\ik\/\\�\\� /\\\\\// \\\%; 37"-93" MED TO COARSE SAND f �"? \ 406 p ff � / o I / / O NO LEDGE, NO WATER, NO MOTTLING 0 co 394 /F, / O PERCOLATION—RATE ` 6 1/8 PER UNCAS HEALTH DISTRICT — DATED: 04/01/2002 4 t �� c,� l' 6� .r 500 GALLO O 3g PERCOLATION RATE: PERC #1 = 28 SECONDS / INCH SEPTIC TA N ! \\151, C)6 co _ .� �':::: R=211 50' MAP REFERENCE \\ \ TOPso�t..... j DELTA = 14• 01' 24" o � ST0CKPa1.U•',/ PROPERTY SURVEY PL�,N PREPARED FOR SAINT THOMAS MORE, INC., COTTAGE L=51,77'%% CHORD =SOUTH 00' 35' 49" WEST 51.64' 8 ROAD, MONTVILLE, CONNECTICUT, BY GME/CPK DESIGN GROUP, NORWICH, REBAR / 96 6" o a CONNECTICUT. DATED: 45/1 B/2002, _. FOOTIN �., \ 14 1/2' DESIGN DATA row►~PERCOLATION RATE = 28 SECONDS/INCH /-s 1 T 10'21 " W 17 3/8" 5 BEDROOM RESIDENCE REQUIRES 825 SF OF LEACHING AREA 11101. \11' `'� �O 29 PROVIDE 23 4' X 4' X 4' GALLERIES u' `' ~`TROVIDE A CONTINUOUS NE �► EFFECTIVE LEACHING AREA = 846 SF / \,l OF SILTFENCE. MAI AIN o \ 34 3/4 PROVIDE A 1500 GALLON 2 -COMPARTMENT TANK TIROUGHOUT CONSTRU ON. \ M,L.S.S. REQUIRED = N/A t� D �'L) GALLERY i � � M.L.S.S. PROVIDED = 92' CROSS SECTION �y o NOT TO SCALE 60' FRONTYARD \ PREPARE AREA OF PROPOSED SYSTEM AS FOLLOWS SETBACK EXISTING N WELL 1.) REMOVE AND STOCKPILE TOPSOIL. \ 0 2.) EXCAVATE 6' WIDE TRENCHES AND PREPARE SURFACE. N 3.) PLACE GALLERY UNITS IN TRENCH WITH ENDS BUTTED TOGETHER TO GA R D E w0 0 �' PROVIDE THE DESIRED LENGTH. . oot 4.) RUN PIPE THROUGH INLET END PLATE (PIPE DOES NOT EXTEND I 10'- 6" ENTIRE LENGTH OF SYSTEM) AND BACKFILL WITH 1" BROKEN STONE SURVEY CLOSING LINE KNOCKOUT INLET AND 5.) PLACE FILTER FABRIC ON TOP" OF STONE OVER ENTIRE SYSTEM. (RFFFRFNCF MAP A11 � i •.._ t.._ � OUTLET OPENINGS 6.) REPLACE TOPSOIL, SEED & MULCH. QUALITY CONTROL CERTIFICATION GROUP REVI WED DATE PROJECT MANAGER r t A SURVEY Y ENVIRONMENTAL CIVIL STRUCTURAL ARCHITECTURAL Fa LE 3 0 i N; o I - - t N z -+ + in — m a CAST CONCRETE COVERS PLAN CAPACITIES A B C 1250 GAL 61" 51" 48" 1500 GAL 69" 59" 56" PROVIDE RISERS TO WITHIN 4 x 4 12.6/12.6 6 x 6 6/6 GA. 12" OF FINISHED GRADE GA. WIRE MESH WIRE MESH 'AT INLET AND OUTLET 4„ PROVIDE OUTLET FILTER i-POLYLOK PL --122 CROSS SECTION 125011500 GALLON 2 _COMPARTMENT SEPTIC TANK NOT TO SCALE NOTES 1.) TOPOGRAPHIC INFORMATION ON THIS PLAN COMPLIES WITH T-2 MAPPING STANDARDS. 2.) BASE FOR LEVELS: ngvd 1929. 3.) PROPOSED HOUSE AND SEPTIC SYSTEM TO BE STAKED IN THE FIELD BY A LAND SURVEYOR LICENSED IN THE 'STATE: OF CONNECTICUT. 4.) LOT AREA = 2.77 t ACRES 5.) BENCHMARK TO BE SET IN AREA OF SEPTIC SYSTEM AT TIME OF CONSTRUCTION. Z V4 ob i� 111 1 Y � � U 0 °� • U � D 2 1] C OD yNV) z •, U Q O o a W 6 I LLJ V) 0 Z Q L U) i V 0 d Ld V) 0 CL 0 ry CL Z 0 0 w ~ Q Q � � Q Q F- I -17 � U Q� F— U Lli 12 Z �z Z 0 Ld of Q = Lj d 0 ``LW �I p U LLJI ^1 J }-- W � Ld Z 2 to o N 0 LLJCLz c' y � I o N S. F. SQUARE FEET z 6 I LLJ V) 0 Z Q L U) i V 0 d Ld V) 0 CL 0 ry CL Z p w ~ Q Q � Q Q w LLJ LL- U) FF FIRST FLOOR Q w �I ELEV ELEVATION to o N I to � c' y � I o N S. F. SQUARE FEET z o w o z o w ra w w 0 U JLLJ rl O0 0 Q z w > 0- c� w0 > 0-1> J Q Li w J U c! U 1-- U Q z 0 w 0 ° I °' I d1 0 1 u 1 0 � -I- TEST HOLE 40' 20' 0 40' DATE: 9/27/2002 412 INVERT ELEVATION GRAPHIC SCALE IN FEET V) z 0 SCALE: 1 " = 40' 0 V) L) z Ld ¢ z LLJ 0 vvi o o w 0 = V it z [Y w a w En w CL N N N > o 0 a Ld LLJ 0 0 Z ~ a Q Q w LLJ U) FF FIRST FLOOR Q �I ELEV ELEVATION to o N I to � c' y � I o N S. F. SQUARE FEET — — 410 — -- EXISTING CONTOURS o o z o w ra w w 412 PROPOSED CONTOURS 0 Y 0 Fo Q w 0 w BUILDING SETBACK LINE ° I °' I d1 0 1 u 1 0 � -I- TEST HOLE 40' 20' 0 40' DATE: 9/27/2002 412 INVERT ELEVATION GRAPHIC SCALE IN FEET SCALE: 1 " = 40' SHEET, 1 OF 1