Loading...
HomeMy WebLinkAboutSewerh9AN HOLE I , INLET-- -- - �- - INSPECTION OPFNINC Iv1ANF-1t�LE QUl _LET 12 INLET RAFFLE ^" -OUTLET FILTER D EVI C E LIQUID 2/3 REQUIRED '; DEPTI-1 CAPACITY 1/3 REQUIRED ...�. -, CAPAC IIS LE-NGTH NOT GREATER THAN 4 TIMES WIDTH OR DEPTH TYPICAL SEPTIC TANK NOTE; CLEANOUT bIAIHOLES AND All eAFFLI:D INSPECTION I�IANHC)LES SMALL QF LOCATED AT A DEP111 NOT GREATER THAN 12" BELOW FINAL. CRADE. AT'PENDIX B A I'PRMFED SEPTIC TA 4K OUTLET FMTTUL� t.l l :{. S.:a1.1..1 ,AL O lJ l l J1 T F LL 1 1_: tS 7<< CT.I:,A-C_ ,fflI ER MODEL ORDaCa S):I;TEMS FrO4A4--36 FT0854--36 6:50 ;EST1254-•36 FT1554-36 TROkS13Y h', .13ON 'IU SAMr.I'.E.E TUB'-TITE Ef4 4- LMTED COINCRETE CO. PLI22 ZABEL Al 00 A1800 24-38" A300 A1801 MIN PERC A100 -BLIP A1800 -HIP WITH AREAS OF COMPACT GRAY SILTY SAND A300 -HIP A1800-liW m q34 y3� m TOPSOIL 6" BROKEN Y _ STONE T SAL LEA - l i� O H SECT! Q NTS A LAYER OF NON -WOVEN FILTER FABRIC SHALL BE PLACED OVER ALL STONE: BEFORE BACKFILUN(;. MI MUM AVERAGE ROLL V!%L,UES FOR FABRIC SHALL BE 1.5 CMZ PER SQUARE YARD ('ER ASTM D--3776), A PERMITTIVITY OF 1,0 SEC PER A'3TM D--4491) AND A TRAPEZOID TEAR OF 15 LBS PER A'3TM D--4533 2"x2"x48" WooD POLE I� r INDUSTRIAL NETTING, SNOW FENCE OR WOMEN WIRE FENCE FOR SUPPORT, FILTER FABRIC B,iCKFILL E _EL 6,l NATIVE SOIL EDIMFNT FENCE ni-- AIT_ NTS 6/f J . 1 Fl 2 VD .w c, T4 r . , } T3 C PF7 v_ UPG"' ''0� z 1, OVERFLOW "D" ��.QX rvoT to SCAL-E \ Wk-l-rA n DEEP TEST PIT DATA 6:40 w 6:50 17" TEST PIT #7 18 3/4" 0-8" TOPSOIL 0Y 8-24" RED BROWN SILTY SANDY SUBSOIL .LE3 24-38" YELLOW BROWN MODERATELY COMPACT SIL`T'Y SAND MIN PERC RATE: 8.0 MINANCH WITH AREAS OF COMPACT GRAY SILTY SAND 38-62" GRAY SLIGHTLY COMPACT MEDIUM SAND WITH COBBLES 7 TAN SLIGHTLY COMPACT MEDIUM SAND AND GOBBLES 36" MOTTLING (GRAY) oil ROOTS 80" GROUNDWATER NO LEDGE r' n TEST PIT #8 0-7" TOPSOIL 7-20" RED BROWN SILTY SANDY SUBSOIL 20-30" YELLOW BROWN SILTY SAND 30-39" TAN SLIGHTLY COMPACT VERY FINE SAND 39-88" GRAY AND TAN SLIGHTLY COMPACT MEDIUM SAND AND COBBLES NO MOTTLING 44" ROOTS 85" GROUNDWATER NO LEDGE TEST PIT #9 0-6" TOPSOIL 6-17" RED BROWN SILTY SANDY SUBSOIL 17-28" YELLOW BROWN SILTY SAND 28-58" GRAY SLIGHTLY COMPACT MEDIUM SAND 58-87" TAN SLIGHTLY COMPACT MEDIUM SAND NO MOTTLING 48" ROOTS NO GROUNDWATER NO LEDGE PERCOLATION TEST DATA P 1- 29" DEPTH 1.25 HR PRESOAK TIME DEEP TEST PIT DATA 6:40 14 '/2" 6:50 17" TEST PIT #7 18 3/4" 0-8" TOPSOIL 0Y 8-24" RED BROWN SILTY SANDY SUBSOIL .LE3 24-38" YELLOW BROWN MODERATELY COMPACT SIL`T'Y SAND MIN PERC RATE: 8.0 MINANCH WITH AREAS OF COMPACT GRAY SILTY SAND 38-62" GRAY SLIGHTLY COMPACT MEDIUM SAND WITH COBBLES 62-84" TAN SLIGHTLY COMPACT MEDIUM SAND AND GOBBLES 36" MOTTLING (GRAY) 40" ROOTS 80" GROUNDWATER NO LEDGE TEST PIT #8 0-7" TOPSOIL 7-20" RED BROWN SILTY SANDY SUBSOIL 20-30" YELLOW BROWN SILTY SAND 30-39" TAN SLIGHTLY COMPACT VERY FINE SAND 39-88" GRAY AND TAN SLIGHTLY COMPACT MEDIUM SAND AND COBBLES NO MOTTLING 44" ROOTS 85" GROUNDWATER NO LEDGE TEST PIT #9 0-6" TOPSOIL 6-17" RED BROWN SILTY SANDY SUBSOIL 17-28" YELLOW BROWN SILTY SAND 28-58" GRAY SLIGHTLY COMPACT MEDIUM SAND 58-87" TAN SLIGHTLY COMPACT MEDIUM SAND NO MOTTLING 48" ROOTS NO GROUNDWATER NO LEDGE PERCOLATION TEST DATA P 1- 29" DEPTH 1.25 HR PRESOAK TIME READING 6:40 14 '/2" 6:50 17" 7:00 18 3/4" 7:10 20'/4" 7:20 21 '/2" 7:30 22 3/4" 7:40 24" MIN PERC RATE: 8.0 MINANCH SANITARY DESIGN CRITERIA P2- 33" DEPTH 1.25 HR PRESOAK TIME READING 6:42 18" 6:52 21" 7:02 23" 7:12 241/4" 7:22 25/4" 7:32 261/4" 7:45 27/45' MIN PERC RATL: 10.0 MIN/INCH "1'1JEjVl:,i` ...: .-i.. GREATER THAN 100 GALLON'S IN SIZE. B. 1000 GALLON TWO COMPARTMENT SEPTIC TANK REQUIRED BY CODE AND PROVIDED. C. DESIGN PERCOLATION RATE: 1.0 TO 10.0 MIN/INCH D. MINIMUM LEACHING SYSTEM SPREAD I -IF -- 28 GRADIENT BETWEEN 4.1 & 60� RESTRICTION BETWEEN 30.1 & 36**' FF - 1.5 THREE BEDROOM HOME PF ,: I.2 PERC RATE BETW'EEN 5.1 & 10.) ?MIN/INCH MLSS=I-IF x FFxPF=28x 1.5x1.2=50.4' E. EFFECTIVE LEACHING AREA REQUIRED PER CODE: 495 SF F. STONE LEACHING TRENCHES SELECTED FOR LEACHING SYSt'EM DESIGN EFFECTIVE LEACHING AREA PROVIDED PER LF PER CODE: � SF MINIMUM LENGTH OF LEACHING TRENCH REQUIRED: w`.95 SF/ 3 SF/LF = 165' G. EFFECTIVE LEACHING AREA PROVIDED 2-90' LONG TRENCHES, 2 x 90' x 3 SF1'LF = 540 SF H. 100%o RESERVE AREA REQUIRED AND PROVIDED LOCATING DIMENSIONS FROM PROP CORNER(DFROM PROP CORNER Y FDN CORNEFQ 62' 211' FDN CORNEA 65' 164' SEPTIC TANK INLET 97' 125' 89' GENERAL NOTES 1. BOUNDARY INFORMATION, WETLAND BOUNDARY AND DEEP TEST PIT DATA AND LOCATIONS TAKEN FROM A PLAN ENTITLED "SUBDIVISION MAP PREPARED FOR NADER EL SAMALOTY RTE 82, CHURCH RD, & DOYLE RD, MONTVILLE, CT." FRANSEN CONSULTANTS. THE BOUNDARY IS CERTIFIED CLASS A-2. 2. THE PERCOLATION TESTS Ow THIS PLAN WERE WITNESSED AND RECORDED BY GARY J. WINALSKI, PE, IN MAY 2002. 3. THIS LOT WAS TOPOED IN THE AREA OF THE HOUSE AND SEPTIC SYSTEM AND A BENCHMARK SET BY DIETER, GARDNER, AND MEREEN, LAND SURVEYORS, IN MAY 2002. 4. AT THE TIME OF THIS DESIGN THERE WERE NO I_XISTING WELLS WITHIN 75' OF THE PROPOSED SEPTIC SYSTEM AND THERE WERE NO EXISTING SEPTIC SYSTEMS WITHIN 75' OF THE PROPOSED WELL LOCATION. 5. FILL PLACED WITHIN 10' OF THE PRIMARY LEACHING SYSTEM SHALL BE SELECT FILL. "SELECT FILL MATERIAL" AND "BACKFILL MATERIAL", PLACED WITHIN AND ADJACENT TO PROPOSED LEACHING AREAS SHALL BE COMPRISED OF CLEAN SAND AND GRAVEL, FREE FROM ORGANIC MATERIAL AND DELETERIOUS SUBSTANCES. THE FILL MATERIAL SHALL MEET THE FOLLOWING REQUIREMENTS UNLESS OTHERWISE APPROVED BY A PROFESSIONAL ENGINEER FOR USE WITHIN THE LEACHING AREA: 1. THE FILL HSALL NOT CONTAIN ANY MATERIAL LARGER THAN THREE (3) INCHES. 2. UP TO 45% OF THE DRY WEIGHT OF THE REPRESENATIVE SAMPLE MAY BE RETAINED ON THE 94 SIEVE. THIS IS THE GRAVEL PORTION OF THE SAMPLE. 3. THE MATERIAL THAT PASSES THE 84 SIEVE IS THEN REWEIGHED AND THE SIEVE ANALYSIS STARTED. 4. THE REMAINING SAMPLE SHALL MEET THE FOLLOWING GRADUATION CRITERIA: SIEVE. SIZE PERCENT PASSING #4 100% 410 0-100% #40 0-50% #100 0-20% #200 0-5% NOTE: PERCENT PASSING THE 440 SIEVE CAN BE INCREASED TO NO GREATER THAN 75% IF THE PERCENT PASSING THE #100 SIEVE DOES NOT EXCEED 10% AND THE #200 SIEVE DOES NOT EXCEED 5%. THE RESPONSIBILITY FOR THE PREPARATION OF A LEACHING AREA UTILIZING "SELECT MATERIAL" IS THAT OF THE LICENSED INSTALLER. THE INSTALLER SHALL TAKE THE NECESSARY STEPS TO PROTECT THE UNDERLYING NATURALLY OCCURRING SOILS FROM OVERCOMPACTION AND SILTATION ONCE EXPOSED. 6. FOUNDATION DRAINAGE SHALL BE LOCATED A MINIMUM DISTANCE OF 25' FROM THE SEPTIC SYSTEM. A RODENT PROOF COVER SHALL BE PROVIDED ON THE FOUNDATION OUTLET DRAIN AT "DAYLIGHT." 7. THE FOUNDATION AND SEPTIC SYSTEM SHALL BE STAKED OUT AND GRADES ESTABLISHED BY A LICENSED LAND SURVEYOR. AT THE TIME OF THIS STAKEOUT THE SURVEYOR SHALL STAKE OUT TEST HOLE W, X, Y, AND Z. 8. APPLICANT: RON BATES MONARCH REALTY RTE 32 UNCASVILLE, CT. 06382 9. ENGINEER: GARY J. WINALSKI 9 HERITAGE DRIVE STONINGTON, CT. 06378 (860) 535-2283 10. AT FOUNDATION EXCAVATION AND PRIOR TO SEPTIC SYSTEM INSTALLATION TEST HOLES W, X, Y, & Z SHALL BE WITNESSED AND RECORDED BY THE UNCAS HEALTH DISTRICT. 11. AFTER FILL IS PLACED AND COMPACTED ITNIUST BE PERC TESTI ;D BY THE UNCAS HEALTH DISTRICT PRIOR TO INSTALLATION. SANITARY ELEVATION DATA V SANITARY INVERT AT FOUNDATION: 436.60 t: ! 40'-4" DIA SCHEDULE 40 ASTM D1785 OR EQUAL PIPE (MIN SLOPE = '/4" PER FT) 1000 GALLON TWO COMPARTMENT SEPTIC TANK INV. 435.75 IN INV. 435.50 OUT (�4 58'-4" DIA SDR 35 PVC PIPE G) MODIFIED HIGH LEVEL OVERFLOW "D" BOX INV. 435.07 IN INV. 434.90 TO TRENCH INV. 435.15 OVERFLOW 6 1 0'=4" DIA SDR 35 PVC PIPE "D" BOX INV. 434.37 IN INV. 434.20 OUT $ 9 90' LONG x 48" WIDE x 12" DEEP STONE Lf, 'AC ZING TRENCH BOTTOM OF TRENCH ELEV: 434.40 $ , 433.70 TRENCH INV: 434.90 $ , 434,20 a ZONING COMPLIANCE TABLE RE (..IQ IRED PROVIDED ` .�Da, BOXS 139 FRONT YARD SETBACK 50' S1' „~---- .: 147' 92 SIDE YARD SETBACK 50' 133' fEy 1.� D BOX LEGEND , j�.vJ "" WELL LOC 70' 270' REAR PARI-) SETBACK 50 66, PROPERTY LINE , l STREET LINE PROPOSED ENGINEERED SEPTIC SYSTEM DESIGN BUILDING SETBACK LINE ro,& -15 orIOTUIi ---- --- .� .� PLOT PLAN EXISTING C c'�- NADER EL SAMALOTY SUBDIVISION PROPOSED CONTOUR oc�LOT 13-9 DEEP TEST PIT LOC � �1� � ®'` ��1111 C CONN RTE 82 & CflURCH DRIVE �r PERC TEST LOC�• • ° NOTE. HOUSE AND SEPTIC SYSTEM LOCATION & ELEVATIONS MONTVILLE, CONNECTICUT AND BOUNDARY S SHOWN TO KEEP ALL LOT CLEARING AND =' SCALE: 1" = 30' MAY 2002 WETLAND CHOSEN A - `` GRADING OUTSIDE' THE 50WETLAND BUFFER -� � • 1. REVISION REVISION A- PLAN REVISED TO INCORPORATE COMMENTS IN A LETTER TO RON BATES ®(jA�°�,y�� �1��'� DTD JULY 19, 2002 PER MEETING WITH MICHAEL KIRBY AND GARY WINALSKI ON JULY 23, �,,��, rn 2002. REVISION B- PLAN REVISED TO MOVE HOUSE SO THAT NO CLEARING OR GRADING WOULD BE REQUIRED WITHIN THE WI�.TLAND BUFFER u