HomeMy WebLinkAboutPlanPERFORATED FOOTING DRAIN I .=t 153.0 (LEVEL) .r HOLE PF \ PROP ED \ WELL \ \ FF L l TEST / I EDM LESS T�IAN 300 (m.) \ 41* PVC INV,OUT=1 0.0 \ " 4 SOLID DRAIN PIPE \ DRAIN TO DAYLIGHT \ INV .OUT=±150.0 /.TTI=-qT Wni F' 1M1= )QKA A 1r)M 25' 1250 dAL.LON \ \ SEPTIC ANK INV.IN=149.25 d INV.OUT=1149.0 / 2' i e4C 4i -'' PROPOSED DRIVE 15' WIDEP.) r /4" PV PROVI E 3 FT OF COYM OVER PIPE (MIN.) f1 PROVIDE LEAN -OUT 20 :ADDITIONAL TEST HOLES WERE / .�-�' -� S ACK EXCAVATED TO THE W AND WEST OF THE---' i` _ -- TOG E - GRAVEL DRIVE LOGE WAS LESS TMAN iso / / / / / / /s4 zi 144iEDGE QTS RON PIN - _ ,.----136 ac _- / T.H. E ESERVE SYSTEM . - ' INSTALL 1 16—\ _S1LTTENCE--(TYP,) -- �..... ' 2 ►� -' �INV.OUT--121:-6--(TRENCH,,___.. I = "7.fi INVyOUT 12 i .8 t 06 04--_ . --` --1 -,-_.- '----- PRIMARY SYSTa4 —56 LF LEA6H I NG ---r 02-�` -GALLt IES (TYP.) / /' '`•. \ __ ___ _ 4 IRON PiN�- --25'03' TEMPORARY c �� - `., �-- _1T1 -TRAM - - -_ —2"-GRUSHED -STONE--- -z ,� T r I)" Tt-1IPV I i_._ - — :2"x2"x48" WOOD STAKE Chesterfield - Road 0I1rC QI A K I 30' 0 30' 60' FILTER FABRIC WITH WOVEN WIRE FENCE, SCALE: 1 "=30' INDUSTRIAL NETTING, OR SNOW FENCE FOR SUPPORT COMPACTED BACKFILL FINISHED GRADE FILTER FABRIC PRECAST CONCRETE 4'x8'x1' LEACHING GALLERY 6" MIN. REGULAR DUTY 1_ r%n"CI„ HS -10 LOADING S I ILT FENCE DETAIL NOT TO SCALE � s � 1 " DIAMETER CRUSHED STONE (TYP.) TYPICAL 12" LEACHING GALLERY TRENCH NOTTO scams IRON PIPE (FNS) TEST PIT DATA WAS RECORDED BY CLA ENGINEERS ON 2/18/04 T P. A 0-24" BROWN SANDY SUBSOIL NO WATER NO MOTTLING LEDGE @ 24" T.P. IB 0-10" TOPSOIL 10"-33" BROWN SANDY SUBSOIL 33"-59" SANDY GRAVEL NO WATER NO MOTTLING LEDGE 0 59" T.P. 0-24" BROWN SANDY SUBSOIL 24"-75" SANDY GRAVEL NO WATER NO MOTTLING LEDGE 0 75" T.T.= D 0-10" TOPSOIL 10"-56" BROWN SANDY SUBSOIL 56"-79" SANDY GRAVEL N0 WATER NO MOTTLING LEDGE 0 79" T.P. JE 0-4" TOPSOIL 4"-30" BROWN SANDY SUBSOIL 30"-50" SANDY GRAVEL NO WATER NO MOTTLING LEDGE ® 50" !,E, -IF 0-6" TOPSOIL 6"-40" BROWN SANDY SUBSOIL NO WATER NO MOTTLING LEDGE 0 40" Te. 0-4" 'TOPSOIL 4"-42" BROWN SANDY SUBSOIL NO WATER NO MOTTLING LEDGE 0 42" T.P. #HH 0-30" BROWN SANDY SUBSOIL/FILL 30"-96" SANDY GRAVEL NO WATER NO MOTTLING LEDGE 0 96" PERC. TEST INFORMATION PERCOLATION TEST DATA THE PERCOLATION 'TEST WAS RECORDED BY CLA ENGINEERS ON 3/9/04 P.T. #1 PERFORMED CSD DEPTH OF 19" PRESOAK @ 2:22 LENGTH OF GALLERY REQUIRED = (660 TIME DEPTH CHANE 2:46 4 1/2" H.F.=10 F.F=2.0 P..F.=1.0 2:48 5 3/4" i 1/4- /4"2:50 2:50 7 1/2" '1 3/4" 2:52 9" 1 1/2- /2"2:54 2:54 10 1/2 '1 1 /2" 2:56 11 1/2" 1" 2:58 12" 1/2" 3:00 12 3/4" 3/4- 3:02 13 1/2" 3/4" 3:04 14" 1 /2" 3:06 14 1/2 3:08 15" 1/2- /2"3:10 3:10 15 1/4" 1/4" 3:12 151/2" 1/4- 3:14 16" 1/2" 3:16 16 1/2" 1 /2" 3:18 17" 1/2" 3:20 17 1/4" 1/4- /4"3:22 3:22 17 3/4" 1/2 " (AVERAGEPERCOLATIONS RATE =30 3 4 MIN/INCH SEPTIC SYSTEM DESIGN DATA PRIMARY SYSTEM: PERCOLATION RATE: 3.4 MIN/IN (LESS THAN 10.1 MIN JIN) 4 BEDROOM HOUSE: EFFECTIVE LEACHING AREA REQUIRED = 660 SF USE A 12" DEEP x 48" WIDE LEACHING GALLERY EFFECTIVE LEACHING AREA OF GALLERY = 5.9 SF/LF LENGTH OF GALLERY REQUIRED = (660 SF)/(5.9 SF/LF) = 111.9 LF SLOPE = 18VF/551_F = 32,7°7o DEPTH TO RESTRICTIVE LAYER = 5" H.F.=10 F.F=2.0 P..F.=1.0 MLSS REQUIRED = 20 LF INSTALL 112 LF 12" LEACHING GALLERY LEACHING AREA PROVIDED = 661 SF RESERVE SYSTEM: SAME AS PRIMARY SYSTEM GENERAL NOTES: 1. ALL WORK AMD MATERIAL (SEPTIC TANK, DISTRIBUTION BOX, PIPE) SHALL CONFORM TO THE CONNECTICUT PUBLIC HEALTH CODE REGULATIONS AND STANDARDS FOR SUBSURFACE SEWAGE DISPOSAL SYSTEM. 2. SEWER LINE FROM FOUNDATION WALL TO SEPTIC SHALL BE 4" SCHEDULE 40 PVC - ASTM 1785 AND JOINTS PER HEALTH DEPT. CODE. 3. TRENCHES SHALL BE SET LEVEL FOR ENTIRE LENGTH. 4. PIPE FROM "D" BOX TO LEACHING GALLERY SHALL BE SOLID PVC FOR 2 FEET. 5. PIPE FROM SEPTIC TANK TO DISTRIBUTION LINES SHALL BE 4" SOLID PVC CONFORMING TO ASTMD-3034 AND SDR -35. 6. THERE ARE PRESENTLY NO KNOWN WATER WELLS WITHIN 75' OF THE PROPOSED SEPTIC STSTEM. 7. PROPERTY OWNER: GARRY HATCH SURVEYING NOTES: 1. THIS MAP HAS BEEN PREPARED IN ACCORDANCE WITH REGULATION OF CONNECTICUT STATE AGENCIES SECTIONS 20-3008-1 THROUGH 2O-30OB--20 AND THE STANDARD FOR SURVEY AND MAPS IN THE STATE OF CONNECTICUT AS ADOPTED BY THE CONNECTICUT ASSOCIATION OF LAND SURVEYORS, INC. ON SEPTEMBER 26, 1996. 2. THE TYPE OF SURVEY PERFORMED IS A TOPOGRAPHIC SURVEY, AND IS INTENDED TO DEPICT THE EXISTING CONDITIONS OF THE LAND AS THEY CURRENTLY EXIST AND TO BE USED AS BASE MAPPING FOR A SITE PLAN. 3. SURVEY WAS PERFORMED ON MARCH 2 & 3, 2004 BY CLA ENGINEERS. CLA Engineers, Inc. CIVIL • STRUCTURAL • SURVEYING 317 Main. Street Norwich, Connecticut No. Date Revision (860) 886-1966 Fax (860) 886-9165 �' 57�5- Chesterfield Road Project No. Montville, Connecticut CLA-3259 Proj. Engineer Al R.A.D. HATCH Date: 3SEPTIC SYSTEM3/5/04 Sheet No. }y 1, S. x f SITE PLAN