1. ALL EXISTING UTILITIES ARE APPROXIMATE ONLY. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY ALL
LOCATIONS PRIOR TO CONSTRUCTION, "CALL BEFORE YOU DIG" IS TO BE NOTIFIED PRIOR TO ANY CONSTRUCTION.
(800-922-4455).
2. THE CONTRACTOR IS RESPONSIBLE FOR OBTAINING ALL APPLICABLE CONSTRUCTION PERMITS, PRIOR TO
CONSTRUCTION, FROM THE MONTVILLE PUBLIC WORKS DEPARTMENT AND THE MONTVILLE ZONING ENFORCEMENT
OFFICER ALONG WITH ANY OTHER APPLICABLE AGENCIES. ALL AGENCIES SHALL BE NOTIFIED AT LEAST 48 HOURS
PRIOR TO CONSTRUCTION.
3. THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL DISTANCES AND LOCATIONS AND QUANTITIES AS DEPICTED
ON THE APPROVED SITE PLAN.
4. THE E & S NARRATIVE CONTAINED IN THESE PLANS ARE CONSIDERED PART OF THE DESIGN OF THIS SITE AND
SHALL BE CONSULTED AS CONSTRUCTION DETAILS.
5. ALL EROSION AND SEDIMENTATION CONTROL MEASURES APPLICABLE TO A GIVEN AREA OF CONSTRUCTION SHALL BE
IN PLACE AND APPROVED BY THE TOWN STAFF PRIOR TO THE COMMENCEMENT OF WORK IN THAT AREA.
6. ALL DISTURBED AREAS OF SHALL BE FINISH GRADED WITH 4" OF TOPSOIL AND SEEDED AS DELINEATED IN THE
SEEDING GUIDELINES.
7. EROSION CONTROL NETTING SHALL BE INSTALLED ON SLOPES OF 2:1 OR STEEPER. CONTRACTOR SHALL DRESS
SLOPES AS REQUIRED UN11L STABILIZATION IS ACHIEVED.
1. THE SEPTIC SYSTEM IS TO BE CONSTRUCTED ACCORDING TO THE CONNECTICUT PUBLIC HEALTH CODE
REGULATIONS AND TECHNICAL STANDARDS FOR SUBSURFACE SEWAGE DISPOSAL SYSTEMS.
2. THE PROPOSED SEPTIC SYSTEM SHALL SERVE A THREE (3) BEDROOM HOUSE WITH NO LARGE TUBS. THE
PERCOLATION TEST YIELDED A RATE OF 12 MINUTES PER INCH, A RATE OF 10.1 TO 20 MIN/INCH HAS BEEN USED
FOR DESIGN PURPOSES. THIS REQUIRES 675 SF OF EFFECTIVE LEACHING AREA. THE PROPOSED SEPTIC SYSTEM IS
AS FOLLOWS:
1,000 GALLON SEPTIC TANK AND 1 ROW OF 40' & 36' LONG 48"x48" LEACHING GALLERIES. LEACHING AREA
PROVIDED = 76 LF x 9.2 SF/LF= 699 EFFECTIVE SF. A 100% RESERVE AREA IS PROVIDED.
MLSS (PER UNCAS HEALTH DISTRICT) = 24 x 1.5 x 1.5 = 54 LF (76 LF PROVIDED).
3. PROPOSED HOUSE SEWER SHALL BE PVC SCHEDULE 40 ASTM D 1785. ALL OTHER SEWER PIPE FOR THE SEPTIC
SYSTEM SHALL BE 4" PVC ASTM D3033 OR D3034 WITH RUBBER COMPRESSION GASKET BELL AND SPIGOT OR
APPROVED EQUAL, EXCEPT FOR LEACHING FIELD PIPING LOCATED WITHIN THE LIMITS OF DRIVEWAY, WHICH SHALL BE
SDR -35 HIGH STRENGTH PVC.
4. THERE ARE NO WELLS WITHIN 75 LF OF THE SEPTIC SYSTEM.
5. THERE SHALL BE NO CUTS WITHIN 50 LF OF THE DOWNHILL SIDE OF THE SYSTEM OR WITHIN 25 LF OF THE SIDES
OF THE SYSTEM. THERE SHALL BE NO STUMPS OR BOULDERS BURIED WITHIN 50 LF OF THE DOWNHILL SIDE OF THE
SYSTEM.
6. SHOULD ANY SIGNIFICANT VARIATIONS FROM TEST HOLE DATA SHOWN (LEDGE, WATER, MOTTLING, SOIL TYPE) BE
DISCOVERED BY THE CONTRACTOR, THE ENGINEER SHALL BE NOTIFIED PRIOR TO CONSTRUCTION OF THE SYSTEM.
7. ALL EXISTING UTILITIES ARE APPROXIMATE ONLY. IT IS THE CONTRACTOR'S RESPONSIBILITY TO VERIFY ALL
LOCATIONS PRIOR TO CONSTRUCTION. "CALL BEFORE YOU DIG" SHALL BE NOTIFIED PRIOR TO ANY CONSTRUCTION
(1-800-922-4455).
8. SITE PREPARATION PROCEDURE:
A. INSTALL SILT FENCE FOR SEDIMENTATION CONTROL AS SHOWN ON PLAN.
B. PLACE AND COMPACT SELECT FILL MATERIAL IN AREA UP TO ELEVATION OF THE TOPS OF THE LEACHING
GALLERIES.
C. INSTALL GALLERIES PER PLAN.
D. INSTALL 6" OF LOAM, GRADE TO PREVENT PONDING AND SEED WITH GRASS TO STABILIZE.
E. ALL TOPSOIL IN THE FILL AREA OF THE PROPOSED PRIMARY SYSTEM SHALL BE REMOVED AND THE SOIL SHALL
BE SCARIFIED PRIOR TO PLACEMENT OF FILL.
F. STRIP TOPSOIL IN AREA OF AND 5 FEET SURROUNDING PRIMARY SEPTIC SYSTEM.
9. THE SELECT FILL SHALL BE COMPRISED OF CLEAN SAND AND GRAVEL, FREE FROM ORGANIC MATTER AND FOREIGN
SUBSTANCES AND IT SHALL MEET THE FOLLOWING REQUIREMENTS:
A. THE FILL SHALL NOT CONTAIN ANY MATERIAL LARGER THAN THREE (3) INCHES.
B. UP TO 45% OF THE DRY WEIGHT OF THE REPRESENTATIVE SAMPLE MAY BE RETAINED ON THE N0. 4 SIEVE
(THIS IS THE GRAVEL PORTION OF THE SAMPLE).
C. THE MATERIAL THAT PASSES THE NO. 4 SIEVE SHALL BE REWEIGHED AND THE SIEVE ANALYSIS
STARTED.
D. THE REMAINING PORTION OF THE SAMPLE SHALL MEET THE FOLLOWING GRADATION CRITERIA:
SIS E PERCENT PASSING
NO. 4 100%
NO. 10 70%-100%
NO. 40 10%-50% (SEE NOTE BELOW)
NO. 100 0%-20%
NO. 200 0%-5%
NOTE: PERCENT PASSING THE NO. 40 SIEVE CAN BE INCREASED TO 75% IF THE PERCENT PASSING THE NO. 100
SIEVE DOES NOT EXCEED 10% AND THE NO. 200 SIEVE DOES NOT EXCEED 5%
THE CONTRACTOR SHALL BE RESPONSIBLE FOR PREPARATION OF THE LEACHING AREA USING SELET FILL AND
SHALL PROTECT THE UNDERLYING NATIVE SOILS FROM OVERCOMPACT10N AND SILTATION.
PERIODIC INSPECTIONS BY THE TOWN SANITARIAN WILL BE REQUIRED AS THE FILLING PROGRESSES.
10. A PERMIT FROM THE UNCAS HEALTH DISTRICT IS REQUIRED PRIOR TO CONSTRUCTION OF THE SYSTEM.
11. CONTRACTOR SHALL PROVIDE RECORD PLANS OF THE SEWAGE DISPOSAL SYSTEM, AS BUILT, TO THE UNCAS
HEALTH DISTRICT.
2004 McFARLAND -JOHNSON, I10C.
These drawings are the prop,e!rty of the Engineer and have been specifically prepared
for the owner of this projec!'at this site, and are not to be duplicated or used in
port or whole for any other G�rpose, project, location or owner without the
expressed written consent of t.ne Engineer.
NARRATIVE:
THIS PROJECT INVOLVES THE DEVELOPMENT OF A RESIDENTIAL LOT CONSISTING OF HOUSE, WELL, DRIVEWAY AND
THE INSTALLATION OF A NEW SEPTIC SYSTEM. THE LOT SIZE IS 14,000 SF (0.32 ACRE). THERE ARE NO
REGULATED WETLANDS ON THE PROPERTY.
SILT FENCE WILL BE INSTALLED DOWN GRADIENT OF ALL CONSTRUCTION AREAS PRIOR TO CONSTRUC110N. TOPSOIL
SHALL BE STOCKPILED ON SITE, SURROUNDED BY SEDIMENT FENCE AND SEEDED WITH RYE GRASS DURING
CONSTRUCTION.
IT IS THE INTENT OF THESE PLANS TO STABILIZE ALL DISTURBED AREAS AS SOON AS PRACTICABI_L AND
ESTABLISH VEGETATION OR INSTALL THE PARTICULAR COVER PROVIDED. ALL MEASURES SHALL BE INSPECTED ON A
WEEKLY BASIS BY THE DESIGNATED ON-SITE AGENT. THE CONTRACTOR SHALL CORRECT ANY PROBLEM AREAS OR
FAILURES OF THE EROSION AND SEDIMENTATION SYSTEMS.
RESPONSIBILITY FOR THE INSTALLATION OF THE EROSION AND SEDIMENTATION PROTECTION AS IDENTIFIED IN THIS
NARRATIVE SHALL BELONG TO THE APPLICANT/OWNER. LARRY DANIELS AT (860) 536-0512 IS THE DESIGNATED
ON-SITE AGENT RESPONSIBLE FOR ASSURING TO THE TOWN THAT ACTUAL MEASURES TAKEN COMPLY WITH THE
CERTIFIED PLAN. WHEN A DIFFERENT INDIVIDUAL BECOMES THE DESIGNATED AGENT, THE TOWN WILL BE NOTIFIED
AND ASSURED THAT THE INDIVIDUAL IS ADEQUATELY QUALIFIED TO ACT AS AGENT.
THE E & S MEASURES ON THE ENTIRE SITE SHALL REMAIN IN PLACE, INSPECTED BY THE ON-SITE AGENT, AND
MAINTAINED BY THE CONTRACTOR UNTIL THE INLAND WETLANDS OFFICER IS SATISFIED THAT THE ASSOCIATED SITE
HAS BEEN STABILIZED.
SEEDING GUIDELINES:
FINAL STABILIZATION OF DISTURBED AND GRADED UPLAND AREAS, UNLESS OTHERWISE NOTED, SHALL BE
LOAAED AND SEEDED. LOAM SHALL BE PLACED AT A MINIMUM COMPACTED DEPTH OF 4". RECOMMENDED
SEEDING DATES FOR PERMANENT VEGETATION SHALL BE BETWEEN APRIL 1 THROUGH JUNE 15 AND AUGUST
15 THROUGH SEPTEMBER 15. TEMPORARY VEGETATIVE MEASURES SHALL CONSIST OF AN ANNUAL OR
PERENNIAL RYE GRASS WITH RECOMMENDED SEEDING DATES BEING FROM MARCH 1 THROUGH JUNE 30 AND
AUGUST 1 THROUGH OCTOBER 15.
EVALUATE PROPOSED COVER MAMS,,ll�l,
BEFORE SPREADING PROPOSED COVER MATERIAL OVER THE DESIGNATED AREA, OBTAIN A REPRESENTATIVE
SOIL SAMPLE AND SUBMIT TO A REPUTABLE SOIL TESTING LABORATORY FOR CHEMICAL AND PHYSICAL
ANALYSIS. THIS PRELIMINARY TEST IS NECESSARY TO DETERMINE THE REQUIRED INORGANIC AND/OR
ORGANIC AMENDMENTS THAT ARE NEEDED TO ASSIST IN ESTABLISHING THE SEED MIXTURE IN AN
ENVIRONMENTALLY AND ECONOMICALLY SOUND MANNER. THE RESULTS WILL GIVE THE COVER MATERIAL
CHARACTERISTICS SUCH AS PH AND FERTILIZATION NEEDS. THESE RESULTS SHALL BE KEPT ON-SITE BY
THE CONTRACTOR AND AVAILABLE FOR REVIEW BY THE TOWN.
SEED BED PREPARATION
PROPOSED COVER MATERIAL SHOULD BE SPREAD EVENLY OVER THE SITE AREA IN A MINIMUM 4" LIFT VIA
BULLDOZER/BUCKET LOADER. USING THE INFORMATION FROM THE SOIL ANALYSIS, CAREFULLY CALCULATE
THE QUANTITIES OF LIMESTONE AND PRE -PLANT FERTILIZER NEEDED PRIOR TO APPLYING. PRE -PLANT
AMENDMENTS CAN BE APPLIED WITH A BROADCAST AND/OR DROP SEEDER AND INCORPORATED WITH AN
OFFSET DISK, YORK RAKE, AND/OR HAND RAKE. AFTER INCORPORATING THE PRE -PLANT SOIL AMENDMENTS,
THE SEED BED SHOULD BE SMOOTH AND FIRM PRIOR TO SEEDING. THE FOLLOWING SEED MIXTURES SHALL
BE USED AS NOTED:
IN 71 1 .4t
SEED TIME AND METHOD
THE PREFERRED TIME FOR SEEDING THE COOL SEASON MIXTURE IS LATE SUMMER. SOIL AND AIR
TEMPERATURES ARE IDEAL FOR SEED GERMINATION AND SEEDLING GROWTH. WEED COMPETIT-10:1 IS REDUCED
BECAUSE SEEDS OF MANY WEED SPECIES GERMINATE EARLIER IN THE GROWING SEASON. ADDITIONALLY,
HERBICIDE USE IS GREATLY REDUCED. HOWEVER, SEEDING MAY BE DONE AT ANY OF THE AB('V;7 NOTED
TIMES.
MULCHING
NEWLY SEEDED AREAS SHOULD BE MULCHED TO INSURE ADEQUATE MOISTURE FOR SUCCESSFUL TURF
ESTABLISHMENT AND TO PROTECT AGAINST SURFACE MOVEMENT OF SEDIMENT -BOUND AGROCHEMICALS AND
SOIL EROSION. APPLY GOOD QUALITY STRAW OR HAY AT A RATE OF 2 BALES/100' SQ. Fl. OTHER
COMMERCIALLY AVAILABLE MULCHES CAN BE USED.
TEST PIT & PERCOLATION TEST DATA
Test Pits and Percolation Tests were witnessed by David Coughlin, Uncas Health District
on 10-7-02.
TEST PIT #1 TEST PIT #3
0"-15" Topsoil 0"-21 " Topsoil
15"-28" Subsoil 21 "-36" Subsoil
28"-74" Grey Compact Sandy Till 36"-76" Grey Compact Sandy Till
No Ledge, no water, mottling ® 33" No Ledge, no water, mottling 0 44"
TEST PIT #2
0"-9" Topsoil
9"-36" Subsoil
36"-80" Sand and Gravel
No Ledge, no water, mottling 0 36"
TEST PIT #4
0"-9" Topsoil
9"-36" Subsoil
36"-74" Grey Compact Sandy Till
Perc Test
TIME READIN
10:20 1 1 "
10:27 13
1/2-
/2"10:41
10:41 15
1/4-
/4"11:02
11:02 17"
11:20 18
1/2 -
/2"Percolation
Percolation rate 0 22"depth = 12 min/inch
No Ledge, no water, mottling 0 38"
SYNTHETIC FABRIC FILTER
FENCE � NVIROFENCE BY
MIRAFI o AOODnvrn cns ini N
WOOD
1
LEACHING GALLERIES
18' ON CENTER
I
PROPOSED GRADE
COMPACTED
BACKFILL
ENCH
)F
LOAM AND SEED,
GRADE TO PREVENT
PONDING
48" MIN. TO LEDGE
4'-10"
5► -5"
4'-8"
APPROVED BACKFILL
FILTER FABRIC
4'x4'x4' CONCRETE
LEACHING GALLERY
(TYP)
(77) 2" x 5"
KNOCKOUTS
48" LEACHING GALLERY
Nis
8'-6'
INLET (TYP.) 3
/ PLACES
if
21 *0 CAST CONCRETE
COVER (TYP.)
PLAN
SECTION
OUTLET
uFnNc
4'-5" GROOM
NOTES:
1. CONCRETE 4,500 PSI - 28 DAYS
2. JOINTS SEALED WITH 3/4" DIA. BUTYL_ RUBBER
3. 4" PVC INLET & OUTLET BAFFLE SUPPLIED BY DEWEY'S
PRECAST, INC.
4. 4" L.P. PVC PIPE SEAL - TYP. (4) PLACES
5. COVER TO BE PLACARD DANGER GAS DO NOT ENTER.
6. SEPTIC TANK SHALL MEET REQUIREMENTS OF ASTM C-1227-95.
7. NON -BY-PASS EFFLUENT FILTER SHALL BE INSTALLED AT THE
OUTLET PER CONECTICUT PUBLIC HEALTH CODE TECHNICAL
STANDARDS, APPENDIX B.
ELEVATION
1,000 GAL. SEPTIC TANK DETAIL
Hrs
4" INLET
n"
A
FI rT
1'-3 1/2"
LPA
1 '-3 1/2
2"
2"
2 1/2-
(3)
/2"
(3) 4" OUTLETS
fi"
1'-4"
r1swit
1. CONCRETE MINIMUM STRENGTH -
4,000 PSI 0 28 DAYS
2. STEEL REINFORCEMENT - ASTM
A--615 GR. 60, A-185, OR A-497,
1" MIN. COVER
3. DESIGN LOADING - LIGHT DUTY
�/X 12"
®®® ® 12Nt
s
1 SIZE STONE
(ALL AROUND)
l
18" MIN. TO GROUNDWATER
OR MOTTLING
48" MIN. TO LEDGE
4'-10"
5► -5"
4'-8"
APPROVED BACKFILL
FILTER FABRIC
4'x4'x4' CONCRETE
LEACHING GALLERY
(TYP)
(77) 2" x 5"
KNOCKOUTS
48" LEACHING GALLERY
Nis
8'-6'
INLET (TYP.) 3
/ PLACES
if
21 *0 CAST CONCRETE
COVER (TYP.)
PLAN
SECTION
OUTLET
uFnNc
4'-5" GROOM
NOTES:
1. CONCRETE 4,500 PSI - 28 DAYS
2. JOINTS SEALED WITH 3/4" DIA. BUTYL_ RUBBER
3. 4" PVC INLET & OUTLET BAFFLE SUPPLIED BY DEWEY'S
PRECAST, INC.
4. 4" L.P. PVC PIPE SEAL - TYP. (4) PLACES
5. COVER TO BE PLACARD DANGER GAS DO NOT ENTER.
6. SEPTIC TANK SHALL MEET REQUIREMENTS OF ASTM C-1227-95.
7. NON -BY-PASS EFFLUENT FILTER SHALL BE INSTALLED AT THE
OUTLET PER CONECTICUT PUBLIC HEALTH CODE TECHNICAL
STANDARDS, APPENDIX B.
ELEVATION
1,000 GAL. SEPTIC TANK DETAIL
Hrs
4" INLET
n"
A
FI rT
1'-3 1/2"
LPA
1 '-3 1/2
2"
2"
2 1/2-
(3)
/2"
(3) 4" OUTLETS
fi"
1'-4"
r1swit
1. CONCRETE MINIMUM STRENGTH -
4,000 PSI 0 28 DAYS
2. STEEL REINFORCEMENT - ASTM
A--615 GR. 60, A-185, OR A-497,
1" MIN. COVER
3. DESIGN LOADING - LIGHT DUTY