HomeMy WebLinkAboutPlan & SewerC)
Q
O
D
O
U
N/E
JEI=I=ERY J. HUTCHIN50N
* JENNIFER V. GILL115
N/E
STEVEN A. * CAREY A.
5CARPA
FROFFK_Y CORNER LOCATION
LINE FSTABLISt1ED BASED ON FIELD 160' FROM MONUMENT FOU IND AND t'ELD
LOCATIONS OF WALL FROM 12/200 1 - AT END OF NOT HERLY LINE OF "'NALL.
EXISTING WALL SHOWN ON 1 927 MAP
S83 @ 1~ 11
G2.001
4GG Froposed three Bedro-ik1 :
o Frame Dwelling
40G -" N ! ` N Garage FF = 400. ! G
�
! - 404401 �
402
2-.
40 aec 4 _ �3, C 6 k-
400
N/l= 111
{Dztst Free Surfacj PT)
J05EPH MEDELLIN 40
-... ;
.TP#F
398 -
0-
B[ACH LANE
N/F
J05EPH F. * MICHELE
TYCz
Inch = 20 Feet
0 20 40 GO 80
In5pection Opening
Minimum 17" (optional) Minimum 17"
Diameter Manhole Diameter Manhole
IrspectiZr
ning
Minimum 17" (optio Minimum
min. 811 min.e
-�- outlet
h1Gltlet _,� ��"_ I (�"� -9" min �5'�iiiin: 101 min. Outlet liter
Baffle 1 i -"- CSN LLL_ Device
Ir�fet g_ 1_-L o" min. 1 O" tire. Outlet F er C
L;affle , 1 l Device, The Montville Zon(n� Board of Ap ea15
Liquid Depth Mid -Depth
2/3 Reeluired Connection 15 not rendering a finding or Gone u51on
Ivlld-D� th
2/3 KA Wty Liquid Depth Conn rtlo
Capacity on the i55ue of owner5hlp of the R.O.W.
I /3 ciuir 1 /3 Pec ulred
Ca a Capacity
Length qe!n&tNbthGreater Than
tdth or Depth
Sec Ion Throujohhh `--
T I TI'` Foucjh
�✓� Ij_ _ . .I Tan INLET 2" ----_�
EX15TING WALL 5110'JfN ON 1927 MAF
PRC)PERTY LINE BA5ED ON FIELD
PKOTECTIVE Bill 1-',IEK
FOR PRO"OSL=i '-1TLL
EDGE DI I',"YEMFNT
DN PIN (SET)
PG\A
N/F
EDWARD M. VI LK15H
David A. King, FEL5
Engneerin�j Surveylna
23 1 Old Colchester Load
Quaker lIlll, CT
3 6
I�L 14 �- OUTLET(S)
SECTION
3 CONCRETE DISTRIBUTION BOX
NOT TO SCALE
1. SET BOX LEVEL ON CONCRETE PAD OVER 12" THICK BASE OF COMPACTED
CRUSHED STONE FILL.
C-33 Si a n d 2. EXTEND DISTRIBUTION PIPES INSIDE BOX TO ALLOW FOR FLOW ADJUSTMENT.
Not to Scale
LEGEND
- - ---
Property Line
Se`ba`
Setback Line
:50 PM
Proposed Grades
_
100 Existing Grades
sftience --
Siltfence
Q
Iron Pm
O
Drill Hole
B[ACH LANE
N/F
J05EPH F. * MICHELE
TYCz
Inch = 20 Feet
0 20 40 GO 80
In5pection Opening
Minimum 17" (optional) Minimum 17"
Diameter Manhole Diameter Manhole
IrspectiZr
ning
Minimum 17" (optio Minimum
min. 811 min.e
-�- outlet
h1Gltlet _,� ��"_ I (�"� -9" min �5'�iiiin: 101 min. Outlet liter
Baffle 1 i -"- CSN LLL_ Device
Ir�fet g_ 1_-L o" min. 1 O" tire. Outlet F er C
L;affle , 1 l Device, The Montville Zon(n� Board of Ap ea15
Liquid Depth Mid -Depth
2/3 Reeluired Connection 15 not rendering a finding or Gone u51on
Ivlld-D� th
2/3 KA Wty Liquid Depth Conn rtlo
Capacity on the i55ue of owner5hlp of the R.O.W.
I /3 ciuir 1 /3 Pec ulred
Ca a Capacity
Length qe!n&tNbthGreater Than
tdth or Depth
Sec Ion Throujohhh `--
T I TI'` Foucjh
�✓� Ij_ _ . .I Tan INLET 2" ----_�
EX15TING WALL 5110'JfN ON 1927 MAF
PRC)PERTY LINE BA5ED ON FIELD
PKOTECTIVE Bill 1-',IEK
FOR PRO"OSL=i '-1TLL
EDGE DI I',"YEMFNT
DN PIN (SET)
PG\A
N/F
EDWARD M. VI LK15H
David A. King, FEL5
Engneerin�j Surveylna
23 1 Old Colchester Load
Quaker lIlll, CT
3 6
I�L 14 �- OUTLET(S)
SECTION
3 CONCRETE DISTRIBUTION BOX
NOT TO SCALE
1. SET BOX LEVEL ON CONCRETE PAD OVER 12" THICK BASE OF COMPACTED
CRUSHED STONE FILL.
C-33 Si a n d 2. EXTEND DISTRIBUTION PIPES INSIDE BOX TO ALLOW FOR FLOW ADJUSTMENT.
Not to Scale
..Qra ..... , .. r.:^ �4' Mi1B/tNl TtBGO�S
t I.:.._.:::-.: r CRUSHED STONE
48 -=- e
5ectlon Through'
5 -BOX 3 ONSTRUCTION ENTRANCE ANTI -TRACKING PAD
NOT TO SCAB
1. CMR AND ME AWA BEFORE RACEINNT OF STIDNE. A GBOTO fLE o-tlt MY BE USED TO
STAB UE POOR SIBKI W SOBS.
2 PROVIDE FOR POSNAVE MWMAGE OF SEDIMENT LADEN MATER THROUGH - SEormtr
OR TO A SE'OBNEiTT BASIN.
3- MAWM ENTRANCE SO AS TO PREVENT TRACKING, OR RDNM OF SED*&"f ONTO PUBM Rf6NT OF 1MAY.
FILTER FABRIC - I
OVERLAP STAKES AT ROLL -i
ENDS TO PREVENT FLOW-THROUGH I -� WOOD STAKE
I (10' O.C. MAX.)
EXCAVATED TRENCH j
TOE IN FABRIC $", BACKFILL -------\ ANGLE STAKES 2`_0" MIN.
AND COMPACT 1 10' TOWARD FLOW
FLOW
MIN.
(T"FILTER FABRIC FENCE
NOT TO SCALE
1. INSPECT BARRIER AFTER EACH STORM EVENT AND DAILY DURING PROLONGED RAINFALL.
2. REMOVE SEDIMENT WHEN IT REACHES APPROXIMATELY ONE-HALF THE BARRIER HEIGHT.
Testhole * Percolation Data:
Date of Percolation Test 4/24/08
Conducted by Dave Coughlin
Witnessed by Bill Coughlin
Presoak Time: 10:30
Percolation Test / Total Depth 54"
Time Depth
10:4G AM 43"
10:5G 4811
10:59 50"
1 1:1 2 53"
stabahzed at 1 .0 iw,h, n «.33 minutes
Solis Test Data Recorded By David Coughlin R5
Witnessed By Bill Coughlin A-2 Maps t Surveys. on 4/24/0(5
Location: North of 8 Beach Lane, Oakdale, CT
Test Pit #4
0-1 0" Topsoil
10-2011 Brown Loamy Sand
20-10 1 " Sand and Gravel
Test Pit #5
0-811 Topsoil
8-3011 Brown Sandy Loam
30-102" Sand and Gravel
Test Pit #G
0-911 Topsoil
9-4 1 " Brown Sandy Loam
41-891, Sand and Gravel
No Mottling, No Ground Water, No Ledge for all Testholes
DRAWN BY: DAK DATE: November 19, 2009
3 02-13-10 perc test added, zonln6i verbagc, added DAK
2 1 �_-2 -09 5011-s type added DAL,
,c,
t
F
2
This survey and map has been prepared in accordance with Sections
20-300b-1 through 20-300b-20 of the Regulations of Connecticut State kjcncies-
Minimum Standards for Surveys and Maps in the State of Connecticut" as endorsed by
the Connecticut Association of Land Surveyors, Inc. It is a Class A-2 Properly Survey.
. This 15 a pre-existing non -conforming lot which is made up
Of lots 05tabll5hed In 1927. Thls lot can be found on map
# 108 and Is designated a5 lot # 116 in the Town of
Montville Assessor's Office.
3. This lot can be found in the R-80 Zone shown on the Town
of Montville'5 Zoning map.
1. Owner/Applicant: Joseph f. 4� Michele Tycz 8 Beach Lane,
Oakdale, CT.
reference Map:
"Plan of Oxoboxo Lake 51te5l, Owned by Oxoboxo Land
Company, 3 14 Thayer Bldg, Norwich, Conn., kale: 1 "=50', by
Chandler * Palmer, Engineers, Norwich, Conn., July 15t. 1927."
e5thole * Percolation Data:
)ate of Percolation Test I / I G/08
�
hour
'ercolation Test / Total Depth 2G"
P fpr
O
Depth
:50 PM
4"
:00
7.75"
G �tSF
1 1:50"
3:20
13.75"
3.30
15.7511
3:40
1 6.7511
):50
17.7511
20 FT
10 FT*
REAR:
50 FT
10 FT*
MAX BLDG HEIGHT:
35 FT
<35 FT
..Qra ..... , .. r.:^ �4' Mi1B/tNl TtBGO�S
t I.:.._.:::-.: r CRUSHED STONE
48 -=- e
5ectlon Through'
5 -BOX 3 ONSTRUCTION ENTRANCE ANTI -TRACKING PAD
NOT TO SCAB
1. CMR AND ME AWA BEFORE RACEINNT OF STIDNE. A GBOTO fLE o-tlt MY BE USED TO
STAB UE POOR SIBKI W SOBS.
2 PROVIDE FOR POSNAVE MWMAGE OF SEDIMENT LADEN MATER THROUGH - SEormtr
OR TO A SE'OBNEiTT BASIN.
3- MAWM ENTRANCE SO AS TO PREVENT TRACKING, OR RDNM OF SED*&"f ONTO PUBM Rf6NT OF 1MAY.
FILTER FABRIC - I
OVERLAP STAKES AT ROLL -i
ENDS TO PREVENT FLOW-THROUGH I -� WOOD STAKE
I (10' O.C. MAX.)
EXCAVATED TRENCH j
TOE IN FABRIC $", BACKFILL -------\ ANGLE STAKES 2`_0" MIN.
AND COMPACT 1 10' TOWARD FLOW
FLOW
MIN.
(T"FILTER FABRIC FENCE
NOT TO SCALE
1. INSPECT BARRIER AFTER EACH STORM EVENT AND DAILY DURING PROLONGED RAINFALL.
2. REMOVE SEDIMENT WHEN IT REACHES APPROXIMATELY ONE-HALF THE BARRIER HEIGHT.
Testhole * Percolation Data:
Date of Percolation Test 4/24/08
Conducted by Dave Coughlin
Witnessed by Bill Coughlin
Presoak Time: 10:30
Percolation Test / Total Depth 54"
Time Depth
10:4G AM 43"
10:5G 4811
10:59 50"
1 1:1 2 53"
stabahzed at 1 .0 iw,h, n «.33 minutes
Solis Test Data Recorded By David Coughlin R5
Witnessed By Bill Coughlin A-2 Maps t Surveys. on 4/24/0(5
Location: North of 8 Beach Lane, Oakdale, CT
Test Pit #4
0-1 0" Topsoil
10-2011 Brown Loamy Sand
20-10 1 " Sand and Gravel
Test Pit #5
0-811 Topsoil
8-3011 Brown Sandy Loam
30-102" Sand and Gravel
Test Pit #G
0-911 Topsoil
9-4 1 " Brown Sandy Loam
41-891, Sand and Gravel
No Mottling, No Ground Water, No Ledge for all Testholes
DRAWN BY: DAK DATE: November 19, 2009
3 02-13-10 perc test added, zonln6i verbagc, added DAK
2 1 �_-2 -09 5011-s type added DAL,
,c,
t
F
2
This survey and map has been prepared in accordance with Sections
20-300b-1 through 20-300b-20 of the Regulations of Connecticut State kjcncies-
Minimum Standards for Surveys and Maps in the State of Connecticut" as endorsed by
the Connecticut Association of Land Surveyors, Inc. It is a Class A-2 Properly Survey.
. This 15 a pre-existing non -conforming lot which is made up
Of lots 05tabll5hed In 1927. Thls lot can be found on map
# 108 and Is designated a5 lot # 116 in the Town of
Montville Assessor's Office.
3. This lot can be found in the R-80 Zone shown on the Town
of Montville'5 Zoning map.
1. Owner/Applicant: Joseph f. 4� Michele Tycz 8 Beach Lane,
Oakdale, CT.
reference Map:
"Plan of Oxoboxo Lake 51te5l, Owned by Oxoboxo Land
Company, 3 14 Thayer Bldg, Norwich, Conn., kale: 1 "=50', by
Chandler * Palmer, Engineers, Norwich, Conn., July 15t. 1927."
e5thole * Percolation Data:
)ate of Percolation Test I / I G/08
'resoak I
hour
'ercolation Test / Total Depth 2G"
Time
Depth
:50 PM
4"
:00
7.75"
10
1 1:50"
3:20
13.75"
3.30
15.7511
3:40
1 6.7511
):50
17.7511
Testhole * Percolation Date:
Date of Percolation Test 211 9/0h
Presoak I Hour
Percolation Test / Total Depth 36"
Time
Depth
12:22 PM
15.25"
12:32
1 G.7511
12:42
18.0"
12:52
19.011
1:02
20.0"
1:12
21.0"
1:22
22.0"
tabalized at 1 .0 inch in less than I O. I minutes stabahzed at 1 .0 inch in less than 10. 1 minute:-,,
ions Test Data Recorded By David Coughlin R5
/Itnessed By Dave King P.E./L.5. on I/ 10/08
.ocation: North of 8 Beach Lane, Oakdale, CT
-est Pit # I
)-1 5" Topsoil
5-38" Reddish Brown Sandy Loam
38-87" Sand and Gravel ter/ cobbles
est Pit #2
(SECTION 7.4 - 7.7)
)-511
Topsoil
)-2411
Reddish Brown Sandy Loam
1 1,255 SF
Sand and Gravel w/ cobbles
est Pit #3
)- 1 011 Topsoil
10-30 Reddish Brown Sandy Loam
3G- 10211 Sand and Gravel w/ cobbles
Flo Mottling, No Ground Water, No Ledge for all Testholes,
)E5IGN CRITERIA FOR 3 BDRM HOUSE
)5e 5 -Box Leaching System NO ML55 REQUIRED
EKCOLATION RATE I INCH IN LESS THAN 10. 1 MIN.
.)Y5TEM REQUIRES 495 S.F. OF EFFECTIVE LEACHING AREA.
F955.1`./28.7 EFFECTIVE LEACHING CREDIT YIELDS 17.24 LF
JSTALL 18LF OF 5 -Box SB- 13GX2G TO PROVIDE 5 1 G SF.
SND 1 000 GAL SEPTIC TANK.
IOU5E TO T ANK: SCHEDULE 40, 4" PVC PIPE
'ANK TO SYSTEM: ASTM D 3034, 5DR35, 411 PVC PIPE.
10 FOOTING DRAINS REQ. The soils on site fall within the Group I ,
;W type 50115 as 115ted in Table 2405. 1 of the 2003 1.R.C.
Septic System Design Elevations:
House Outlet= 399
Tank Inlet Invert= 398.45
Tank Outlet Invert= 398.20
D -Box Inlet Invert= 398.0
Leaching Area Bottom Elev.- 395.0
ZONING COMPLIANCE TABLE R- 80 ZONE
(SECTION 7.4 - 7.7)
REQUIRED
PROVIDED
MIN LOT AREA:
80,000 SF
1 1,255 SF
MIN LOT FRONTAGE:
180 FT
150.4 FT
M i N YARDS:
FRONT: PIZ,e tv njBedc} e"e
50 FT
10 FT's
FRONT: - opstV;n� eDrve
50 FT
50 FT
SIDE:
20 FT
10 FT*
REAR:
50 FT
10 FT*
MAX BLDG HEIGHT:
35 FT
<35 FT
Requesting a reduction in side, front, and rear yard setbacks and to
Sieptic DC51cjn Prepared for
J05e,ph * Michele Tycz
TE-5-1,tD.ach, 1--anelOxciboxicli L
t area.
5HEET NUMBED'.
OF
I
C
fl�