HomeMy WebLinkAboutPlan• A A AIL 1. DIG A 6" TRENCH ON THE UPHILL SIDE OF THE BARRIER LOCATION. 2. POSITION THE POSTS ON THE DOWNHILL SIDE OF THE BARRIER AND DRIVE THE OU 1 -547.7 POST 1.5 FEET INTO THE GROUND. IN[ ILTRATOR=546.2 3. LAY THE BOTTOM 6" OF THE FABRIC IN THE TRENCH TO PREVENT UNDERMINING AS WITNESSED BY THE UNCAS HEALTH DISTRICT AND BACKFILL. TEST HOLE #640A 4. INSPECT AND REPAIR BARRIER AFTER HEAVY RAINFALL. 5. SEDIMENT DEPOSITS ARE TO BE REMOVED WHEN THEY REACH A HEIGHT OF ONE 38"-97" GRAY COMPACT GRAY SANDY TILL FOOT BEHIND THE BARRIER AND ARE TO BE DEPOSITED IN AN AREA WHICH IS 0"-7" TOPSOIL & ROCKS NOT REGULATED BY THE INLAND WETLANDS COMMISSION. 6. INSPECTIONS AND NECESSARY REPAIRS WILL BE MADE TWICE WEEKLY. TEMPORARY VEGETATIVE COVER A TEMPORARY SEEDING OF RYE GRASS WILL BE COMPLETED WITHIN 15 DAYS OF THE FORMATION OF STOCKPILES, IF THE SOIL IN THE STOCKPILES HAS BEEN COMPACTED BY CONSTRUCTION OPERATIONS IT SHALL BE LOOSENED TO A DEPTH OF 2 INCHES BEFORE THE FERTILIZER, LIME AND SEED IS APPLIED. 10-10-10 FERTILIZER AT A RATE OF 7.5 POUNDS PER 1000 S.F. LIMESTONE AT A RATE OF 90 LBS. PER 1000 S.F. SHALL BE USED. RYE GRASS APPLIED AT A RATE OF 1 LB. PER 1000 S.F. SHALL PROVIDE THE TEMPORARY VEGETATIVE COVER, STRAW FREE FROM WEEDS AND COARSE MATTER SHALL BE USED AT A RATE OF 70-90 LBS. PER 1000 S.F. AS A TEMPORARY MULCH. APPLY MULCH AND DRIVE TRACKED EQUIPMENT UP AND DOWN SLOPE OVER ENTIRE SURFACE SO CLEAT MARKS ARE PARALLEL TO THE CONTOURS. PERMANENT VEGETATIVE COVER TOPSOIL WILL BE REPLACED ONCE THE EXCAVATION HAS BEEN COMPLETED AND THE SLOPES ARE GRADED TO A SLOPE NO GREATER THAN 2.5 TO 1. PROVIDE SLOPE PROTECTION ON ALL CUT SLOPES. TOPS01L WILL BE SPREAD AT A MINIMUM COMPACTED DEPTH OF 4 INCHES. ONCE THE TOPSOIL HAS BEEN SPREAD, ALL STONES TWO INCHES OR LARGER IN ANY DIMENSION WILL BE REMOVED AS WELL AS DEBRIS, APPLY AGRICULTURAL GROUND LIMESTONE AT THE RATE OF TWO TONS PER ACRE OR 100 LBS. PER 1000 S.F. APPLY 10-10-10 FERTILIZER OR EQUIVALENT AT A RATE OF 300 LBS, PER ACRE OR 7.5 LBS. PER S.F. WORK LIMESTONE INTO THE SOIL TO A DEPTH OF 4 INCHES. INSPECT SEEDBED BEFORE SEEDING, IF TRAFFIC HAS COMPACTED THE SOIL, RE -TILL COMPACTED AREAS. APPLY THE FOLLOWING GRASS SEED MIX: KENTUCKY BLUEGRASS 20 0.45 CREEPING RED FESCUE 20 0.45 PERENNIAL RYEGRASS 5 0.10 45 1.00 THE RECOMMENDED SEEDING DATES ARE: APRIL 1 - JUNE 15 AND AUGUST 1 - SEPTEMBER 15 FOLLOWING SEEDING, FIRM SEED BED WITH A ROLLER. MULCH WITH WEED FREE STRAW IMMEDIATELY FOLLOWING SEEDING. IF A PERMANENT VEGETATIVE STAND CANNOT BE ESTABLISHED SUBDIVISION PLAN, ALLISON'S WAY SUBDIVISION, PREPARED FOR RTT DEVELOPMENT, INC., CHAPEL HILL ROAD & FORSYTH ROAD, MONTVILLE, CT, PREPARED BY CME/CPK DESIGN GROUP, 110 BROADWAY, NORWICH, CT, DATED: 1/01/03, REVISED TO: 6/20/2003. OU 1 -547.7 TEST HOLE DATA IN[ ILTRATOR=546.2 PER REFERENCE PLAN PERFORMED ON 12/16/03 TEST HOLE #638 AS WITNESSED BY THE UNCAS HEALTH DISTRICT 0"-9" TOPSOIL & ROCKS TEST HOLE #640A 9"-48" BROWN SANDY LOAM W/ BOULDERS 0"-7" TOPSOIL & ROCKS NO LEDGE, WATER 0 5", NO MOTTLING 7"-38" BROWN SANDY LOAM 38"-97" GRAY COMPACT GRAY SANDY TILL TEST HOLE #639 NO LEDGE, NO WATER, MOTTLING CSD 38" 0"-7" TOPSOIL & ROCKS 7"-39" BROWN SANDY LOAM TEST HOLE #64OB 39"-87" GRAY TO TAN SILTY SAND W/ROCKS 0"-8" TOPSOIL & ROCKS NO LEDGE, WATER 017", MOTTLING CSD 39" 8"-39" BROWN SANDY LOAM 39"-90" GRAY COMPACT GRAY SANDY TILL TEST HOLE #640 NO LEDGE, NO WATER, MOTTLING CSA 39" 0"-7" TOPSOIL & ROCKS 7"-39" BROWN SANDY LOAM TEST HOLE #641 A 39"-88" COMPACT GRAY SILTY SAND W/ROCKS 0"-4" TOPSOIL & ROCKS NO LEDGE, WATER ® 20", MOTTLING 0 39" 4"-32" BROWN SANDY LOAM 32"-105" GRAY COMPACT SANDY TILL TEST HOLE #641 NO LEDGE, WATER 0 32", MOTTLING 0 32" 0"-3" TOPSOIL & ROCKS 3"-39" BROWN SANDY LOAM TEST HOLE #641B 39"-95" COMPACT GRAY SILTY SAND W/ROCKS 0"-4" TOPSOIL & ROCKS NO LEDGE, WATER 0 21", MOTTLING @ 39" 4"-35" BROWN SANDY LOAM 35"-99" GRAY COMPACT SANDY TILL TEST HOLE #635A NO LEDGE, WATER ® 23", MOTTLING CSD 33" 0"-1" TOPSOIL 1"-38" BROWN SANDY LOAM TEST HOLE #641C 38"-84" COMPACT GRAY SILTY SAND 0"-4" TOPSOIL & ROCKS NO LEDGE, WATER 0 24", MOTTLING ® 38" 4"-32" BROWN SANDY LOAM 32"-94" GRAY COMPACT SANDY TILL TEST HOLE #636A NO LEDGE, WATER ® 26", MOTTLING ® 31 " 0"-2" TOPSOIL 2"-27" BROWN SANDY LOAM PERCOLATION RATE: 16 MIN/INCH 27"-92" COMPACT GRAY SILTY SAND AS RECORDED BY THE UNCAS HEALTH DISTRICT NO LEDGE, WATER CSD 28", MOTTLING ® 34" TEST HOLE #637_ A 0"-4" TOPSOIL 4"-26" BROWN SANDY LOAM 26"-92" COMPACT GRAY SILTY SAND NO LEDGE, WATER ® 28", MOTTLING ® 34" TEST HOLE #6358A 0"-5" TOPSOIL 5"-38" BROWN SANDY LOAM 38"-93" COMPACT GRAY SILTY SAND NO LEDGE, WATER ® 24", MOTTLING CSD 38" LOT #43/9- 018 PROPERTY LINE ' 1 PROPOSED 4 BUILDING BEDROOM RESIDENCE SETBACK LINE = �' ` � D 12' DRIVE o o' OB 1 TH#638, m _7A R.1 ----- ��, TEMP. �B 4itPJC'v50TH#6V30n �. j AREA H #640 01 � SF F.F. D-BO�, #2 TH 5A 55.0 f TH#63$ p - D - Box \# 1 (U. J , REVERSE ! z LOT 3/9 019 TH#641A f cin �' 10 L.F. 4" PVC 01 TH#s41 SDR, 35 1 1 TH#639 INSTALL TH#641 B '\ SILTFENCE� i' 1,500 GAL. l` CONNECT FOUNDATION DRAIN SEPTIC TANK 27 L.F. 4" PVC \ TO EXISTING CATCH BASIN INV. IN=549.50 SCHEDULE 40 1 4" SOLID PVC SCHEDULE 40 INV. OUT=549.25 INV.=550.5 W/ GASKETED COMPRESSION JOINTS (SEE NOTE 9) LOT #43/9-020 40' 0 40' 80' SCALE: 1 "=40' D -BOX # 1 - REVERSED INV. IN --`)47.5 INV. DISI -.=547.5 INV. OU 1 -547.7 BOT. IN[ ILTRATOR=546.2 D -BOX #2 INV. IN=546.7 INV. DIST=546.7 BOT. INFILTRATOR=545.7 11,_0„ 8" TYP. 2 PLACES I" /\1Y rT -,- --- Q T 6...1 - r.V-%. - r1rC 3G4FAL TYP. 3 PLACES PLAN VIEW PERCOLATION RATE INFORMATION PROVIDED PER REFERENCE PLAN PERCOLATION RATE: LOT #43/9-021=10.4 MIN/INCH DESIGN DATA PERCOLATION RATE = 10.1-20 MIN./INCH 4 BEDROOM RESIDENCE REQUIRES 900 SF OF LEACHING AREA PROVIDE 250 L.F. OF HIGH CAPACITY INFILTRATOR UNITS 2 ROWS OF 125 L.F. AT 9' O.C. EFFECTIVE LEACHING AREA = 250 LF x 3.9 SF/LF = 975 SF PROVIDE 1,500 GAL. 2 -COMPARTMENT TANK M.L.S.S. REQUIRED = 34 x 2.0 x 1.5 = 102 L.F. M.L.S.S. PROVIDED = 125 L.F. PREPARE AREA OF PROPOSED SYSTEM AS FOLLOWS 1. REMOVE AND STOCKPILE TOPSOIL. 2. PLACE BANK RUN GRAVEL (LESS THAN 5% FINES) PLACED IN 6" LIFTS AND COMPACTED TO 95%4 DENSITY. 3. EXCAVATE 4' WIDE TRENCHES AND PREPARE SURFACE. 4. FILL TRENCHES WITH 1" WASHED STONE TO HEIGHT OF PIPE INVERTS PLACE PIPE IN TRENCH, AND FILL TO 2" OVER TOP OF PIPE. 5. CAP ENDS OF PIPES. 6. PLACE A 4' WIDE STRIP OF NON -WOVEN FILTER FABRIC ON TOP OF THE ENTIRE LENGTH OF THE SYSTEM AND BACKFILL WITH NATIVE MATERiAL. 7. REPLACE TOPSOIL, SEED & MULCH. r �C) MAXIMUM I POST WIRE MESH FENCING COMPACTED BACKFILL AFTER ---� PLACEMENT OF SILT FENCE SILT FENCE DETAIL NOT TO SCALE FILTER FABRIC 12" BANKRUN --� GRAVEL 11 " 16" �- 3" 2'-10" HIGH CAPACITY INFILTRATOR NOT TO SCALE 24"DIA. 24"DIA. 6" COVER COVER 18" 6" 20" INLET BAFFLE ' 6" WALLS " _ OUTLET - LIQUID - �- FILTER OUTLET d" LEVEL DEVICE 4" L. P. P.V.C. 6" - PIPE SEAL CROSS SECTION VIEW 1,500 GALLON SEPTIC TANK NOT TO SCALE 14o. I Date GENERAL NOTES 1. TOPOGRAPHIC INFORMATION ON THIS PLAN COMPLIES WITH T-2 MAPPING STANDARDS. 2. BASE FOR LEVELS: SUBDIVISION MAP. 3. PROPOSED HOUSE AND SEPTIC SYSTEM TO BE STAKED IN THE FIELD BY A LAND SURVEYOR LICENSED IN THE STATE OF CONNECTICUT. 4. LOT AREA = 1.28t ACRES 5. ALL WORK AND MATERIAL (SEPTIC TANK, DISTRIBUTION BOX, PIPE) SHALL CONFORM TO THE CONNECTICUT PUBLIC HEALTH CODE REGULATIONS AND STANDARDS FOR SUBSURFACE SEWAGE DISPOSAL SYSTEM. 6. SEWER LINE FROM FOUNDATION WALL TO SEPTIC SHALL BE 4" SCHEDULE 40 PVC - ASTM D 1785 AND JOINTS PER HEALTH DEPT. CODE. 7. TRENCHES SHALL BE SET LEVEL FOR ENTIRE LENGTH AND HAVE A CENTER TO CENTER SPACING OF 9 FEET. 8. PIPE FROM SEPTIC TANK TO DISTRIBUTION LINES SHALL BE 4" SOLID PVC CONFORMING TO ASTMD-3034 AND SDR -35. 9. FOUNDATION DRAIN PIPE FROM HOUSE TO OUTLET SHALL CONFORM TO TABLE 2-C OF THE CONNECTICUT PUBLIC HEALTH CODE REGULATIONS AND STANDARDS FOR INSTALLATION WITHIN 25 FEET OF A SEWAGE DISPOSAL SYSTEM. 10. THERE ARE PRESENTLY NO KNOWN WATER WELLS WITHIN 75' OF THE PROPOSED SEPTIC SYSTEM. 11. A VERTICAL BENCHMARK WILL BE PROVIDED WITHIN 100 FEET OF ;THE PROPOSED HOUSE LOCATION PRIOR TO THE START OF CONSTRUCTION. 12. CLEAR AND GRUB THE AREA WHERE THE SEPTIC SYSTEM AND HOUSE ARE TO BE CONSTRUCTED, ALL TOPSOIL IS TO BE STRIPPED AND STOCKPILED FOR FUTURE USE. 13. ALL FILL MATERIAL SHALL BE CLEAN EARTH FREE OF STUMPS„ ORGANICS, CONSTRUCTION DEBRIS AND TOPSOIL. 14. TOPSOIL SHALL BE RE-APPLIED OVER ALL FILL AREAS AND ALL DISTURBED AREAS TO PROVIDE A MINIMUN DEPTH OF FOUR INCHES. 15. ALL EXISTING UTILITIES TO BE ACCURATELY LOCATED PRIOR TO CONSTRUCTION. 16. IF BLASTING IS REQUIRED A PRE -BLAST SURVEY WILL BE REQUIRED. CALL BEFORE YOU DIG: 1-800-922-4455. i • r 1�`1W,NNN`����� 6" CRUSHED GRAVEL (COMPACTED) 12" GRAVEL _J (COMPACTED) BITUMINOUS DRIVE NOT TO SCALE 4" TOPSOIL +�+•�� • • � • •• + • �• +'•�•�� �•� ` � • � +'•moi ��•Z+Z����+ +••• * +• tom+ • •� • •• i � •� • • ai r'�_•i 4" CLEAN FILL--"' LOAM & SEED CROSS-SECTION DETAIL NOT TO SCALE w r . y > � 0 m No. 20847 �t�a�ra -480- 1 V_0" 480- LEGEND PROPERTY LINE SETBACK LINE - - - EXIST. CONTOURS EDGE OF ROAD EDGE OF DRIVEWAY r- 7 PRIMARY SEPTIC SYSTEM L- RESERVE SEPTIC SYSTEM -84 PROPOSED CONTOUR LINE CLA Engineers, Inc. 1 CIVIL •STRUCTURAL •SURVEYING 317 Main Street Norwich, Connecticut Revision (860) 886-1966 Fax (1360) 886-9165 RTT Development, Inc. PrCLA t 3186 Proj. Engineer ALLISON'S WAY SUBDIVISION L.M.S. #9 ALLISON'S WAY Da 1,/'13/U4 MONTVILLE, CT Sheet No. rr Septic Design - Lot #43/9-019