HomeMy WebLinkAboutUncas Health (Incas Health District
372 W. Main St. 2nd Floor.
Norwich, CT 06360-5450
Telephone No. (860) 823-1189 I FAX No. (860) 887-7898
E-Mail: chfsanit@uncashd.org I Internet: http://www.uncashd.org
Serving the People of Norwich and Montville
February 11, 2004
SUBJECT: MONTVILLE, CONNECTICUT REVIEW OF ENGINEERING PLANS FOR A HOUSEHOLD
SUBSURFACE SEWAGE DISPOSAL SYSTEM, 20 Allison's Way, revised 2/3/04.
TO: RTT Development 35 Blais Road Uncasville, CT 06382
FROM: Michael J. Kirby,R.S., Chief Sanitarian
ENGINEER: Lawrence M. Sullivan, P.E. DATE RECEIVED: February 5, 2004
REASON FOR SUBMISSION: [X] NEW CONSTRUCTION
[ ] MINIMUM PERC RATE LESS THAN 30 MIN./IN.
[X] HIGH MAXIMUM GROUND WATER LEVEL [ ] REPAIR
[ ] SHALLOW LEDGE ROCK
[ ] OTHER
75 FT PROVIDED
MLSS: 72 FT
DESIGN SPECIFICATIONS• REQUIRED,
# OF BEDROOMS: 4 DESIGN PERC RATE: 6.9 MIN/IN
SEPTIC TANK: 1500 GALS. LEACHING SYSTEM: 3 —75' rows of 4'trenches,
serial distribution, 675 s.f.
FILL:None
DRAINS: Footing, outlet off the NE corner WATER SUPPLY: Proposed well off the SE corner
of the house of the garage
[ ] APPROVED.
[X] APPROVED WITH MODIFICATIONS OR PROVISIONS NOTED.
[ ] CONDITIONAL APPROVAL SUBJECT TO FURTHER TESTING AS NOTED.
[ ] CONDITIONAL APPROVAL WITH MODIFICATIONS OR PROVISIONS NOTED.
[ ] APPROVAL DENIED. INSUFFICIENT INFORMATION ON PLAN.
[ ] APPROVAL DENIED. REVISE AS NOTED.
[ ] APPROVAL DENIED, FURTHER SITE INVESTIGATION REQUIRED.
COMMENTS:
1] A test hole must be dug in the reserve area prior to the start of construction.
2] A benchmark must be set in the area of the septic system.
3] Plans for residential septic systems are to be on a scale of 1" to 20' or 30'.
4] Prior to the start of construction, the house, well, and system are to be staked by a licensed surveyor.
c: Engineer