Loading...
HomeMy WebLinkAboutGas Logs 2015 Field Inspection Notice Town of Montville Building Department 860-848-3030 Ext. 382 Address: 55 Pruett Place Job Description: Gas Log Insert in Existing Fireplace Permit Number(s) M2015-0014 Permit Date: January 22,2015 Not Approved INSPECTION Date: Comments Special Conditions Gas pressure test • 7 PSI 1/26115 DJ • • Installed in Gas Log preexisting 1/26/15 DJ wood fired metal fire place. Final inspection and • certificate of approval 1/26/15 DJ Rev.Date: 1/18/06 Page 1 of 1 TOWN OF MONTVILLE Building Department 310 NORWICH-NEW LONDON TURNPIKE UNCASVILLE, CT 06382-2599 TEL. (860) 848-3030 X382 FAX. (860) 848-7231 MECHANICAL PERMIT Permit Number:_M20_15I014 Date: 22J.orLLS_Map/Lot:_004101 R1100___-�_____Owner ID: 5703000 Project Location: 55 PRUETT PLACE _ Unit: Job Description: _Install Gas_Loa_in.Exis ina_Fireelace___ ---- -- Owner Nam C1 orLesJ3_ansi_Suson C Cnlemcn _ Tenant Name N/A__._ Careof: _55 Pn lett PI 0_akdn e CT _0637_0- _ Telephone: 18(OL442-00.8..3 Applicant Name ,prone Owner _ Telephone: DBA: Lic/Reg Type Lic/Reg N 0_ Exp Date: Conetructic+: _ P-emiLFPQs Coestruio_n Infnrmasn Building Value: $0.510— Building Fee: $0.00_ Use Group: IRC Plumbing Value: MOD Plumbing Fee: SEM__ Code: 2005 State Building Code Mechanical Valu $_850,00 Mechanical Fe 53(1-00_ Electrical Value: S_OAL Electrical Fee: SO:00__ Construction Type IRC Total Value: S850.00 Penalty Fee: 50.00_ Permit Code: R5 --- C of 0 Fee: Snon Comment Plan Review Fe S1100_ State Ed Fee: $0.22 Total Fee Paid: S39,22_ It shall be the owners repsonsibility to schedule the following inspections a minimum of 2 business days in advance: Field set of approved construction documents shall be available onsite during all inspections. BUILDING PERMIT INSPECTIONS PLUMBING,MECHANICAL,ELECTRICAL PERMIT INSPECTIONS ❑ Footing-Prior to pouring concrete ❑ R Plumbing and leak test ❑ Deck Piers ❑ R Electrical ❑ Backfill-Footing drains and waterproofing ❑ Elec Trench-with conduit installed ❑ Concrete Slab-Prior to pouring concrete ❑ Pool Bonding ❑ Anchor Bolts-with sill plate and prior to floor frami ❑ Electrical Service CRS No: ❑ Framing ❑ R HVAC ❑ Masonry Fireplace Throat or Chimney Thimble 0 Gas Piping and leak test ❑ Fireblocking Draftstopping INSPECTION REQUIRED UPON COMPLETION ❑ Insulationifi a of Approval '❑ C cote of Occupancy BiiU lir 0lficLc71's Aour_omd: — --- — --- 1 / Town of Montville Building Department 310 Norwich-New London Tpke. Tel. 860-848-3030, Ext 382 Uncasville, CT 06382 Fax. 860-848-7231 RESIDENTIAL PERMIT APPLICATION FORM Permit No.: imao►S—C�.�l`� Type of Work Occupancy Type Permit Type ❑New Construction ® Single Family ❑Building ❑Addition ❑Two-Family ❑Plumbing [s-Alteration ❑Townhouse Mechanical 0 Accessory Structure 0 Electrical CRS#: Property Address: S•S PRI../E77 P/d (Number) (Street) (Unit) Job Description:_ 5 ��erie22,99�7 Owner: G.,‘,/,.&Z.4:5 .4riM NI-1--.54/71/ L/5�Lu�.ri Address: ��,,,���S�i� 3V&TT �lfl / City:CQ,Ce)!L� State: CT Zip Code: �637D Telephone( ac) )54f2- 3 Applicant: DBA: 1,14-/t/e — Address: City: State: Zip Code: Telephone( ) Contractors - Complete the Following: License Type: License No.: Expiration Date: I hereby certify that the proposed work will conform to the State Building Code and all other codes as adopted by the State of Connecticut and the Town of Montville and further attest that the proposed work is authorized by the owner in fee and that I am authorized to make application for a permit for such work as described above. Qr By checking this box, I will follow the requirements of the 2005 NEC as the alternative compliance per section E3301.2.1 of the Residential Code, instead of the electrical requirements in chapters 33 through 42 of the Residential Code. Owner/Agent Signatur-• � �t l�� be-- M Date: '4- Construction Value Permit Fees Building Value: Building Fee: Plumbing Value: Plumbing Fee: Mechanical Value: Mechanical Fee: 30 Electrical Value: Electrical Fee: Total Value: 8 50.o' Penalty Fee: C of 0 Fee: Plan Review Fee: State Ed Fee: 05-) Total Fee: 3o 4V-viaed August 23,2007 Town of Montville Building Department File Receipt Date: 21-Jan-15 ReceiptNo: 10090 Received From: Susan Couchon Coleman Job Address: 55 Pruett Place Town Fees Collected State of Connecticut Fees Collected Bldg Cash: $0.00 State Cash: $0.00 Bldg Check: $30.22 State Check: $0.22 Bldg Credit: $0.00 State Credit: $0.00 Fire Cash: $0.00 Fire Check: $0.00 Fire Credit: $0.00 Construction Value: $850.00 Demolition Value: $0.00 CheckNo: 5766 Received By: Carmen Kneeland Clan yyt con fri K-u.. .Qc-rd ) tesrz.t., State of Connecticut `�C `' �'� N c Workers' Compensation Commission ,f. :. io :r z�j"� W Please TYPE or PRINT IN INK `Y Proof of Workers' Compensation Coverage when Applying for a Building Permit for the Sole Proprietor or Property Owner who WILL NOT act as General Contractor or Principal Employer APPLICANT FOR BUILDING PERMIT • `�Name of Applicant for Building Permit S Q. Q lLe 11,1 Q Property located at55 p/Z( e- PI in the City/Town of r/ a__k Jct.-(`e- v 6,3 7'6 ATTEST If you are the owner of the above-named property or the sole proprietor of a business doing work on the site of the construction project at the above-named property and you WILL NOT act as the general contractor or principal employer,you are not required to have workers'compensation insurance coverage. CHECK ONE(1) BOX ONLY and complete the following: 4 C]q I am the OWNER of the above-named property.I WILL NOT act as the general contractor or principal employer. C 1) ci C"---/2-a- r7. Signatureof OWNERAppfrarsty ❑ I am the SOLE PROPRIE 1 OR of a business doing work at the above-named property.I WILL NOT act as the general contractor or principal employer. Name of Business Federal Employer ID#(FEIN) Signature of SOLE PROPRIE I OR Applicant Town of Montville Building Department CONSTRUCTION PERMIT APPROVAL Applicant is responsible for obtaining all of the required approvals. No permit will be issued until all the required signatures are obtained. Property Address �cy S / c G C . Job Description Required Department Permit Issuance Approval Approval ® Tax Collector Signatu4re/dat Comments: 1111 Planning &Zoning s -4 Signature/date t Comments: ® Fire Marshal . 742•4 -'2-1)1-' `/c ,j / c Signature/date Comments: ❑ Health Department Required for properties with private septic or well Comments: ❑ WPCA, Administrative Required for properties on sewer Signature/date Comments: ❑ WPCA, Operations When Required by WPCA Signature/date Comments: [� Department of Public Works Required when project includes driveway work or certain drainage requirements Signature/date Comments: ❑ Montville Police Department • Required for all permits EXCEPT one and two family residential Signature/date Comments: ❑ State Dept. of Transportation Required for Structures over 100,000 sq.ft.or with more than 200 parking spaces-Official cop of STC Certificate of O•eration re•uired—•er CGS 14-311 Signature/date Building Department Review Complete Signature/date Revised-May 23,2011 installation INSTALLATION CONSIDER THE FOLLOWING: (For chase installation instructions, see Pages 6 and 7) If installation is in a Mobile Home, the overall height 1. Decide on location and where combustion air from bottom of fireplace to chimney flue outlet is to be ducts will be located. Check to be sure all cut- not less than 11 feet or more than 20 feet when outs will avoid most number of ceiling joists, installed with 8FSL firestop thimble and 8RTSA Spark floor joists, frame beams, etc. Avoid any ducting " Arrestor Round Top. The firestop thimble must extend equipment or other obstructions which might from ceiling through the roof. interfere above the fireplace and between the If the installation is residential, overall height is to be fireplace and the combustion air inlets. not less than 11', (when installed with 8FSL firestop BE SURE THAT STRUCTURAL INTEGRITY OF THE thimble that must extend through the floor at the first MOBILE HOME IS MAINTAINED. ceiling). At other ceiling levels a firestop spacer must 2. Carefully lay out the dimensions required on the be used. If minimum overall height is 16' or more, wall, if combustion air will be taken by that 8FSL firestop thimble is not necessary. However, method. firestop spacers must be used at all ceiling levels. If NOTE: The floor does not need reinforcing unless heavy facing materials are going to be used, i.e., Decorative Chimney is used, overall height may be reduced to 12' 6". Chimney may be 90' in height but large areas of stone or brick. However it must be must be supported at every 35 foot level. completely solid to prevent any cold air from en- 1. Provide the necessary clearances. (Figs. 1 and 2.) tering room from under fireplace. IF TO BE INSTALLED IN A MOBILE HOME OR The fireplace may touch combustible materials at RESIDENTIAL BELOW 16' OVERALL, FOLLOW the bottom, sides and back. Above joist area, STEPS 3, 4 AND 5. materials.chimney must h ave y 1" clearance s the topof combustible ibllthe 3. Lay out the 173/4"x 173/4" minimum opening on the Ge fireplace to the first joist are required a minimum keyholeeing. Cut out this area in ceiling with saw. (If residential and overall height is clearance of 3 inches. Firestop spacers MUST be above 16', use regular firestop spacer 141/2"x installed at ceiling level. For Residential use, the 141/2" cutout). 8FSL Thimble (if used) must extend through the CAUTION: Take care to avoid cutting any wiring first floor ceiling joists. At other floors, regular or plumbing above the ceiling. This opening will firestop spacers may be used. They will provide be hidden by the fireplace framing. the necessary clearance to the joists. Install the 4. Lay out and cut out same size opening in roof. Fireplace no closer than is indicated in Fig. 1 to SUGGESTION: Drill upward from the four corners any combustible wall perpendicular to the fire of the ceiling cutout, through the roof to locate place openings, unless a Preway Wall Shield, the proper position for the roof cutout. ; Model WS40 (or an equivalent approved by the 5. Frame in the minimum 173/4"x 173/4" hole o en- local authority having jurisdiction over the installa- P tion of the unit) is installed. This does not apply ing in roof and ceiling. NOTE: Check local codes. to corner installation (See Fig. 8) or walls with Some codes will not allow cutting of roof trusses. insulated shields (WS40). If so, the fireplace can only be installed in an out- 2. The installation will be easier and cost less if side chase on an outside wall or in homes with roof trusses which are a minimum of 211/4" on joists or rafters are not cut as the chimney is center. See Page 7 on chase construction. assembled. 3. The fireplace may be installed directly on the floor, DOUBLE HEADERS NAILED IN PLACE or an elevated wood or masonry platform may be used. Be sure fireplace is on a solid continuous floor or platform so no cold air can enter room from under fireplace. 173/x" ♦ `', 173/4" The fireplacerounmay betpositioned and b then the fram- ing built around it, or the framing may be constructed and the fireplacepushed into the opening. • P P 9• (Fig. 5.) Location and Installation 111,\\, fj 7 0 _____>_z , ..44%. 7400.40001/ 11 FULL "r' PROJECTION HOLE _j;- Vier FOR ' CHIMNEY-- � , STUB JOISTS NAILED ,0.� FIG. 4 TO JOISTS CORNER r • 0 FOR FLAT ROOF INSTALLATION ONLY FIG. 3 FLUSH To place headers in flat roof, mark a line parallel to (CHASE INSTALLATION) opening in roof and ceiling on joists. Measure thick- CAUTION ness of header back from this line. (Fig. 4.) ,,r, Nail stub joist at each of these marks. Nail headers If framing is to be inset from the sides of the to stub joists. If necessary, shims can be placed between headers in same manner. (Fig. 4.) In some fireplace above the fireplace then the chimney spacers TSK8 must be attached before framing. cases hole may be cut near joist. In this case nail shim directly to joist at side of opening. 4 installation 4" COMBUSTION AIR DUCT ATTACH EACH SECTION TO FIREPLACE Framing AND OUTSIDE VENT COVER ASSEMBLY HEADER WITH 4" HOSE CLAMPS SUPPLIED I USE DUCT TAPE AT EACH JOINT j 1 I I I I, TO BE SURE AIR TIGHT. i (RECOMMENDED DUCT BE INSULATED) I ` I OUTSIDE UPWARD \ 1 STUDS VENT THRU 24' i COVER OUTSIDE I l REMOVE THESE WALL SCREWS AND LIFT AND REMOVE FRONT GRILLE TO HOSE i I i I INSTALL BLOWER r._,•-, CLAMP i I IIIIIIIII " "'llllllflll 1 i��r, I RECEPTACLE 1 ii I FOR USE �.., '���{ ®111 WITH -Ai - ; WITH OUTSIDE .' BLOWER VENT COVER 010SIP _ ��'�WIRING ACCESS VIII PLATE FLEXIBLE THRU 4" DUCT ; IIIIIIIIIIlIIIlIIII 16" OUTSIDE ` EXTENSION HEARTH WALL <\ ii,.--)" 1 DOWN THRU RECESS FRAMING PLACE METAL STRIP FLOOR FOR THICKNESS OF UNDER FIREPLACE FIG. 5 WALL OR FACING AND HEARTH EXTENSION See Chart 2 for Dimensions COMBUSTION AIR INLETS There are two 4"diameter inlets, one on each side of for the combustion air duct. Be sure to extend 5" the fireplace. Barometric dampers are installed in these openings all the way through to outside air source. inlets automatically opening and closing them. Two 4" They must be through any insulation, vapor barrier, or diameter flexible 42" long ducts are supplied to duct sheet metal to the outside of the home. outside air to the fireplace. The combustion air ducts can Secure combustion air duct with screws. Push duct be upward, downward, along side of fireplace or at the (with screen grill) through wall or floor from outside rear (if the fireplace is on an outside wall). These and secure to duct attached to fireplace. Attach intake barometric dampers allow the combustion air to be grill and outside vent cover to wall or flooring with taken from any direction including above the fireplace. screws. Use duct tape on all joints to be sure they are DO NOT TAKE AIR FROM ATTIC SPACE, ABOVE THE air tight. ROOF, OR ANY OTHER ROOM, ESPECIALLY GARAGE. FIRESTOP Do not take air from area where another fuel burning Position firestop or firestop/thimble in ceiling cutout appliance is installed. and fasten securely to ceiling. The thimble must ex- If the flexible duct is not long enough to extend to the tend upward through the upper part of the floor or outside, it can be extended with any 4" diameter metal ceiling insulation. On a flat roof, or mobile home, it pipe to any length needed. must extend up into the roof flashing. If it does not, a thimble extension kit is available from your dealer or When installing the combustion air ducts, attach to fireplace and inlets firmly with hose clamps provided. an extension may be locally constructed from the same Use duct tape on all joints to be sure they are air tight. gage material as the thimble and overlap the original, ( It is recommended that these ducts be wrapped with one inch. Trim the thimble sleeve above the roof as insulation to prevent condensation. required to allow flashing to fit flush on roof. On residential, no shield is necessary above the thimble See examples in Figs. 8, 9, 10 and 11. as 1" clearance to triple wall pipe is all that is required Locate the outlets and cut 5" min. diameter holes in attic (or other) space above. 5 installation FRAMING Electrical Code and all local codes and their require- Frame in the fireplace enclosure and push fireplace ments. Have the wiring installed by a qualified person. into it, or place fireplace in position and frame around NOTE: Speed control has White and Black wires, both it. Place metal strip (provided) under fireplace and of which must be connected into hot line as shown in extending out to where it will be under hearth ex- diagram. tension also. This will prevent any sparks reaching HEARTH EXTENSION the floor between fireplace and hearth extension. See Chart 2 for width of hearth extension. The Hearth Extension must extend at least 16" in Secure fireplace to floor with screws provided. front of and at least 8" beyond each side of the fire- place opening. Use Preway Hearth Extension HE28, IMPORTANT: For your safety and protection, the HE28 1, for 28" and HE36, HE36-1 for 36" fireplace or fireplace and chimney should be grounded. Use a ground rod, clamp and wire to ground fireplace and /4" thick non-combustible insulating material with a chimney. thermal conductivity of K=0.55 BTU/IN/HR/FT SQ °F. This may be covered with non-combustible materials ELECTRICAL which do not ignite and burn. Such materials consist An electric junction box (with grounded receptacle) is of steel, iron, brick, tile, concrete, slate, asbestos, glass located at the lower right, behind the bottom grill or plaster or any combination. (Fig. 5). This is for use with the optional blower only CHIMNEY CHASES (Page 15). The front of bottom grill may be removed, for installation of the blower, by unscrewing three A chase is an enclosure for the fireplace and chim- screws in grill (See Fig. 5). Electrical wiring connec- ney or multiple chimneys alone. It can start from the tions may be made through the wiring access plate basement floor line, first floor, part way up the out- without removal of receptacle or grill. side wall or on the roof itself. Wire the receptacle into an electrical circuit during Consult local codes regarding height and construc- the framing of the fireplace. A U.L. listed general use tion details in your area. wall switch rated at 15 Amp. 125 VAC minimum may A chase should be constructed (and insulated) just be used in the circuit or the speed control supplied as any other outside wall. The outside cover must with blower. The fireplace junction box has a wiring be of a material designed for exterior use. access plate next to the '/8" hole provided for connec- tion of a electric wire fitting. Refer to wiring diagram FIRESTOP Chimney Enclosures below. Locate the wall switch close to the fireplace in SPACER a wall box. ) 04/ 9 t Installation of wiring must comply with the National t I J ENCLOSURES SUPPORT MUST BE TOP ELBOW —...ii ,41 90° TO THE WITH STRAPS I FLOOR AND TO JOISTS 15° or 30° CEILING Elbow ON ALL 14/ . FLOORS ABOVE FIRST JOIST LEVEL OPTIONAL BLOWER MIN. WIRING DIAGRAM 1" MIN. ' 4. WHITE FIRESTOP ---I-- SPACER I SPEED CONTROL 1.13.. ..45( JUNCTION BOX :0 (SWITCH SUPPLIED / IN FIREPLACE x WITH BLOWER) IQ ti / BLACK 1I03m —00"'.41--3" MIN. ( l___J OR CURCUIT BLACK TO FUSE / ZERO CLEARANCE _ r WHITE BREAKER ENCLOSURESTO WHITE . MUST BE SPACERTOP(TSK8) FACTORY SUPPLIED 90° TO THE / ---- PID FLOOR ANDZERO NOT SUPPLIED E .. CEILING CLEARANCE ON ALL TO TOP NOTE: Speed control has White and Black FLOORS ABOVE SPACER'S wires, both of which must be connected into FIRST JOIST ZERO hot line as shown in diagram. LEVEL .8--CLEARANCE TO SIDES , ,..1 CHASE FRAMING INSET FRAMING FIG. 6 NOTE: Do not use more than four elbows per installation and never over 30° maximum. Elbow may be mounted directly on fireplace. 6 installation The fireplace chase must have the same insulation as cover the complete top to prevent water leakage. A used in the house side walls. Many codes require a 6" high collar attached to this pan will keep the triple closure at the first ceiling level with a firestop spacer wall pipe at its proper minimum height over pan. Use installed. water proof caulking around all seams to be sure it is The chase must be insulated up to a minimum of this weather tight. By constructing a chase in this fashion, level (higher if more than one story) and also the the fireplace will be installed in a "warm" room and cold air will be prevented from entering the home. closure insulated with ceiling insulation. through any portion of the fireplace. The base of the chase must also be insulated be- tween the solid continuous floor beneath the fireplace NOTE: The triple wall chimney pipe must extend and the chase bottom. This will break the cold con- at least 6" above the chase top unless an 8CC chase ductivity into the fireplace. cap is used. A metal pan, made by local sheet metal shop, must STUD O 8" ROUND (JOISTS) TOP INSULATE `o 1 TERMINATION IN BETWEEN N.....00' SAME AS STORM CEILING 400 - COLLAR 14141441, 6" CHASE COLLAR ( 00/1 (135/s" DIA.) \ CHASE O METAL TOP I � <>:,,, �SOLID SURFACE qi ��FIRESTOP P it SPACER ``1� / `T/ /014 0 I ,,,[j;„,,' li 14'.. INSULATE OUTSIDE / 8 FOOT WALLS CHASE COLLAR LEVEL BETWEEN ::......... �- / STUDS 6' MIN. STORMR 4110 • _t— ammmi CHASE METAL I -o.l TOP i I I SOLID CONTINUOUS SURFACE REFER TO PAGE 3 FORlir INSULATION MINIMUM OVERALL HEIGHT (THERMAL OF FIREPLACE TO FLUE OUTLET BARRIER) MAY USE 8CC CHASE CAP OUTSIDE WITH 8CCSA SPARK ARRESTOR \ BASE FIG. 7 7 METHODS OF RUNNING COMBUSTION AIR DUCTS FOR ENERGY MIZER® SYSTEM J SECOND FLOOR OUTSIDE �, INSIDE g_ i 14--- _____.____._ 1 WALL , ROOM 8FS FIRESTOP SPACER rftil DUCT rI EXTENDED ri COMBUSTION TO MISS AIR DUCT JOIST rUP AND OVER1, OMNI U C 0 Li I iTOP OF FIREPLACE TO OUTSIDE , WALL ALSO • I_I_ 1 45° Corner Installation on Slab Floor III Wall, Inside Room) Basement or Crawl Space Installation FIG. 8 FIG. 10 CAUTION! Do Not Take Combustion Air From Attic Space or Garage PLATE 8RTSA d \____L ROUND TOP S 8FSL TO OTHER FIRESTOP 0111101 SIDE AND SNOW 1,______ --- SPACER DOWN THROUGH LEVEL ► SOFFIT ,�� f_-- ,, i _ i INLET — I 'tea. GRILLE GROUNDS - IN LEVEL _ SOFFIT " LI [1 " (OVER- HANG) I `Th BASEMENTi \:: --' 1_} • ' '• WALL Concrete Slab Installation Basement Installation (Under 16' Overall Height) FIG. 9 FIG. 11 8 installation Framing Dimensions FIG. 12 — 8RTSA TOP RAIN CAP � T t .....-- ..._ CHIMNEY CAP ADAPTOR A I} I f 3' MIN. TO FLUE ■ TRIPLE WALL PIPE I B � 0 p OUTLET LET MA� STORM COLLAR 7 E L , BFSL FLASHING __:, _ � ly J 7 - FIRESTOP L. SPACER 4"DIA. T HF — (OVERALL K _ UNDERHT 16') G A INITEINIM1DAMPER 1 HANDLE 24" % CLOSED —OPEN INLET AIR "_ ~ � DAMPER HANDLE H f [11 . ' FIG. 13 CHART 2 Dimensions 28", 36" Fireplace TO INSTALL CHIMNEY CMODEL MODEL Chimney may be regular 8" triple wall pipe with MEASUREMENT 6128 EM 6136 EM 8RTSA top, 8CC chase cap or complete 8DCT Decorative A 14Y2"(SQ.) 141/2"(SQ.) Chimney. Refer to 8CC or 8DCT Manual for installa- See Note(1) tion instructions. B 15" 173/4" Position triple wall pipe on top of the fireplace. C 21" 25" Match seam of triple wall pipe into notch of ring on top of fireplace. Attach the pipe section to the fire- D 231/2" 271/2" place with screws provided. If an offset is needed to E 35" 39" miss a joist or rafter, use a 15° or 30° Elbow Kit. F 16" 16" Mobile home installations of 12'6" and over may use 2 elbows. Residential installations of 16' and over may G 35" 39" use 4 elbows. Do not angle pipe over 30°. (See Chart See Note(3) on Page 16.) H 21" 25" Maintain 1" minimum clearance to combustibles for See Note(3) sections located above the joist area where the fire- 1 491/2" 551/2" place is located. Maintain 3" clearance to combustibles See Note(3) for sections located directly above the fireplace. (See Figure 6.) See Note(3) 42" 50" Add additional sections of triple wall pipe until pipe is 8" to 16" above roof. Screw sections of pipe to- K 70" 78" gether with three screws provided. See Note(3) HEARTH x 16" 52"x 16" ON FLAT ROOF OR EXTENSIONINIRESEMS HOME See Note(2) _ FTP SPACER NOTES —i= > THIMBLE MUST EXTEND 1. Opening for chimney is 141/2" sq. for residential 8" TO ABOVE UPPERMOST SIDE 16" OF ROOF CUTOUT AND installation over 16 ft., 173/4" sq. for mobile home INTO FLASHING. TRIM Cinstallation or residential under 16 feet. SLEEVI AS REQUIRED 2. Los Angeles code requires Hearth to be 12" each TO SET FLASHING. side of the Fireplace opening and 20" deep. 3. This dimension is for one elbow each side, point- FIG. 14 ing down. If more elbows are required, this dimension will have to be increased. 9 installation IF INSTALLED IN MOBILE HOME FINISHING At this point it must not exceed 131/2' road clearance. The fireplace installation can be finished in an infi- This will allow the top sections of the chimney to be nite variety of ways. removed after completion, and permit moving the mobile home on the highway. • DO NOT block off the air opening at the top or bottom of the fireplace. Pull flashing up and coat the area inside the mark- • Any mantel must be 12"or more above the fireplace Ings with a good quality roof cement (not provided). top grille opening. Push flashing down and press it firmly into the roof cement. Fasten the flashing securely to the roof using nails or screws. Coat the heads with roof cement. Fasten the storm collar around the triple wall pipe a C A MANTEL few inches above the flashing. Apply a bead of water- 12" MIN. proof caulking (not provided) around the pipe, just A------A i, above the flashing. Push the storm collar down on the flashing. Apply caulking around the top of the storm collar to seal it to the triple wall pipe. Illllllllllllla_...IIIIIIIIIIIII I - I A I = A I I B----4 4------B I I I r t I PUSH DOWN--;41,_ IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII 11 4 FIG. 16 STORM I I COLLAR .`J CAULKINGNOTE / Do not allow any opening between the front of FLASHING the fireplace and the surrounding materials. Cold air may enter or hot air be lost if there is an opening. Fill this area with non-combustible FIG. 15 caulk or equal. Check with local codes for installa- tion procedure. A— Do not install combustible material closer than line A. Install the remaining sections of triple wall pipe until B — Do not install non-combustible material any closer pipe with round top is 36" above roof. than 1/2" to line B for clearance for doors. C — Non-combustible material can be installed up to this line. NOTE • For finishes using non-combustible facings, the materials may overlap the frame of the fireplace The Flue Outlet MUST be at least 3 feet above the up to within 1/2" of the opening on either side. It roof surface top cutout and 2 feet above the should not extend below Line C above the fireplace highest point within 10 feet horizontally (See opening. The finish materials may be anchored Fig. 13). using metal screws into the fireplace frame. • If triple wall pipe above the roof is to be painted, paint it with galvanized primer and then paint with color desired. Install the Round Top Assembly. Set it on top of CAUTION the triple wall pipe, align screw holes and secure with J 3 screws provided. All sections of pipe must be at- Do not block off the circulating air opening at tached together with 3 screws to prevent any pipe the top or bottom front of the fireplace. becoming loose. 10