Town of Montville
Building Department
860-848-3030 Ext. 382
Address: 55 Pruett Place
Job Description: Gas Log Insert in Existing Fireplace
Permit Number(s) M2015-0014 Permit Date: January 22,2015
Not Approved
INSPECTION Date: Comments Special
Conditions
Gas pressure test • 7 PSI 1/26115 DJ
• • Installed in
Gas Log preexisting 1/26/15 DJ
wood fired
metal fire place.
Final inspection and •
certificate of approval 1/26/15 DJ
Rev.Date: 1/18/06 Page 1 of 1
TOWN OF MONTVILLE
Building Department
310 NORWICH-NEW LONDON TURNPIKE
UNCASVILLE, CT 06382-2599
TEL. (860) 848-3030 X382 FAX. (860) 848-7231
MECHANICAL PERMIT
Permit Number:_M20_15I014 Date: 22J.orLLS_Map/Lot:_004101 R1100___-�_____Owner ID: 5703000
Project Location: 55 PRUETT PLACE _ Unit:
Job Description: _Install Gas_Loa_in.Exis ina_Fireelace___ ---- --
Owner Nam C1 orLesJ3_ansi_Suson C Cnlemcn _ Tenant Name N/A__._
Careof:
_55 Pn lett PI
0_akdn e CT _0637_0- _ Telephone: 18(OL442-00.8..3
Applicant Name ,prone Owner _ Telephone:
DBA: Lic/Reg Type
Lic/Reg N 0_
Exp Date:
Conetructic+: _ P-emiLFPQs Coestruio_n Infnrmasn
Building Value: $0.510— Building Fee: $0.00_ Use Group: IRC
Plumbing Value: MOD Plumbing Fee: SEM__ Code: 2005 State Building Code
Mechanical Valu $_850,00 Mechanical Fe 53(1-00_
Electrical Value: S_OAL Electrical Fee: SO:00__ Construction Type IRC
Total Value: S850.00 Penalty Fee: 50.00_ Permit Code: R5 ---
C of 0 Fee: Snon Comment
Plan Review Fe S1100_
State Ed Fee: $0.22
Total Fee Paid: S39,22_
It shall be the owners repsonsibility to schedule the following inspections a minimum of 2 business days in advance:
Field set of approved construction documents shall be available onsite during all inspections.
BUILDING PERMIT INSPECTIONS PLUMBING,MECHANICAL,ELECTRICAL PERMIT INSPECTIONS
❑ Footing-Prior to pouring concrete ❑ R Plumbing and leak test
❑ Deck Piers ❑ R Electrical
❑ Backfill-Footing drains and waterproofing ❑ Elec Trench-with conduit installed
❑ Concrete Slab-Prior to pouring concrete ❑ Pool Bonding
❑ Anchor Bolts-with sill plate and prior to floor frami ❑ Electrical Service CRS No:
❑ Framing ❑ R HVAC
❑ Masonry Fireplace Throat or Chimney Thimble 0 Gas Piping and leak test
❑ Fireblocking Draftstopping INSPECTION REQUIRED UPON COMPLETION
❑ Insulationifi a of Approval
'❑ C cote of Occupancy
BiiU lir 0lficLc71's Aour_omd: — --- — ---
1 /
Town of Montville
Building Department
310 Norwich-New London Tpke.
Tel. 860-848-3030, Ext 382 Uncasville, CT 06382 Fax. 860-848-7231
RESIDENTIAL PERMIT APPLICATION FORM Permit No.: imao►S—C�.�l`�
Type of Work Occupancy Type Permit Type
❑New Construction ® Single Family ❑Building
❑Addition ❑Two-Family ❑Plumbing
[s-Alteration ❑Townhouse Mechanical
0 Accessory Structure 0 Electrical CRS#:
Property Address: S•S PRI../E77 P/d
(Number) (Street) (Unit)
Job Description:_ 5 ��erie22,99�7
Owner: G.,‘,/,.&Z.4:5 .4riM NI-1--.54/71/ L/5�Lu�.ri
Address: ��,,,���S�i� 3V&TT �lfl /
City:CQ,Ce)!L� State: CT Zip Code: �637D Telephone( ac) )54f2- 3
Applicant:
DBA: 1,14-/t/e —
Address:
City: State: Zip Code: Telephone( )
Contractors - Complete the Following:
License Type: License No.: Expiration Date:
I hereby certify that the proposed work will conform to the State Building Code and all other codes as adopted by the State of Connecticut and the Town
of Montville and further attest that the proposed work is authorized by the owner in fee and that I am authorized to make application for a
permit for such work as described above.
Qr By checking this box, I will follow the requirements of the 2005 NEC as the alternative compliance per section E3301.2.1 of the Residential Code,
instead of the electrical requirements in chapters 33 through 42 of the Residential Code.
Owner/Agent Signatur-• � �t l�� be-- M Date: '4-
Construction Value Permit Fees
Building Value: Building Fee:
Plumbing Value: Plumbing Fee:
Mechanical Value: Mechanical Fee: 30
Electrical Value: Electrical Fee:
Total Value:
8 50.o' Penalty Fee:
C of 0 Fee:
Plan Review Fee:
State Ed Fee: 05-)
Total Fee: 3o
4V-viaed August 23,2007
Town of Montville
Building Department
File Receipt
Date: 21-Jan-15 ReceiptNo: 10090
Received From: Susan Couchon Coleman
Job Address: 55 Pruett Place
Town Fees Collected State of Connecticut Fees Collected
Bldg Cash: $0.00 State Cash: $0.00
Bldg Check: $30.22 State Check: $0.22
Bldg Credit: $0.00 State Credit: $0.00
Fire Cash: $0.00
Fire Check: $0.00
Fire Credit: $0.00 Construction Value: $850.00
Demolition Value: $0.00
CheckNo: 5766
Received By: Carmen Kneeland Clan yyt con fri K-u.. .Qc-rd
) tesrz.t., State of Connecticut `�C
`'
�'� N
c Workers' Compensation Commission ,f. :.
io
:r z�j"� W Please TYPE or PRINT IN INK `Y
Proof of Workers' Compensation Coverage when Applying
for a Building Permit for the Sole Proprietor or Property Owner
who WILL NOT act as General Contractor or Principal Employer
APPLICANT FOR BUILDING PERMIT
• `�Name of Applicant for Building Permit S Q. Q lLe 11,1 Q
Property located at55 p/Z( e- PI
in the City/Town of r/ a__k Jct.-(`e- v 6,3 7'6
ATTEST
If you are the owner of the above-named property or the sole proprietor of a business doing work on the site of the construction project at the above-named
property and you WILL NOT act as the general contractor or principal employer,you are not required to have workers'compensation insurance coverage.
CHECK ONE(1) BOX ONLY and complete the following:
4
C]q I am the OWNER of the above-named property.I WILL NOT act as the general contractor or principal employer.
C 1)
ci C"---/2-a- r7.
Signatureof OWNERAppfrarsty
❑ I am the SOLE PROPRIE 1 OR of a business doing work at the above-named property.I WILL NOT act as the general contractor or principal employer.
Name of Business
Federal Employer ID#(FEIN)
Signature of SOLE PROPRIE I OR Applicant
Town of Montville
Building Department
CONSTRUCTION PERMIT APPROVAL
Applicant is responsible for obtaining all of the required approvals. No permit will be issued until all the required signatures are obtained.
Property Address
�cy S / c G C .
Job Description
Required Department Permit Issuance Approval
Approval
® Tax Collector
Signatu4re/dat
Comments:
1111 Planning &Zoning s -4
Signature/date t
Comments:
® Fire Marshal . 742•4 -'2-1)1-' `/c ,j / c
Signature/date
Comments:
❑ Health Department
Required for properties with private septic or well
Comments:
❑ WPCA, Administrative
Required for properties on sewer Signature/date
Comments:
❑ WPCA, Operations
When Required by WPCA Signature/date
Comments:
[� Department of Public Works
Required when project includes driveway work or certain drainage requirements Signature/date
Comments:
❑ Montville Police Department •
Required for all permits EXCEPT one and two family residential Signature/date
Comments:
❑ State Dept. of Transportation
Required for Structures over 100,000 sq.ft.or with more than 200 parking spaces-Official cop of STC Certificate of O•eration re•uired—•er
CGS 14-311
Signature/date
Building Department Review Complete
Signature/date
Revised-May 23,2011
installation INSTALLATION
CONSIDER THE FOLLOWING: (For chase installation instructions, see Pages 6 and 7)
If installation is in a Mobile Home, the overall height 1. Decide on location and where combustion air
from bottom of fireplace to chimney flue outlet is to be ducts will be located. Check to be sure all cut-
not less than 11 feet or more than 20 feet when outs will avoid most number of ceiling joists,
installed with 8FSL firestop thimble and 8RTSA Spark floor joists, frame beams, etc. Avoid any ducting "
Arrestor Round Top. The firestop thimble must extend equipment or other obstructions which might
from ceiling through the roof. interfere above the fireplace and between the
If the installation is residential, overall height is to be fireplace and the combustion air inlets.
not less than 11', (when installed with 8FSL firestop BE SURE THAT STRUCTURAL INTEGRITY OF THE
thimble that must extend through the floor at the first MOBILE HOME IS MAINTAINED.
ceiling). At other ceiling levels a firestop spacer must 2. Carefully lay out the dimensions required on the
be used. If minimum overall height is 16' or more, wall, if combustion air will be taken by that
8FSL firestop thimble is not necessary. However, method.
firestop spacers must be used at all ceiling levels. If NOTE: The floor does not need reinforcing unless
heavy facing materials are going to be used, i.e.,
Decorative Chimney is used, overall height may be
reduced to 12' 6". Chimney may be 90' in height but large areas of stone or brick. However it must be
must be supported at every 35 foot level. completely solid to prevent any cold air from en-
1. Provide the necessary clearances. (Figs. 1 and 2.) tering room from under fireplace.
IF TO BE INSTALLED IN A MOBILE HOME OR
The fireplace may touch combustible materials at
RESIDENTIAL BELOW 16' OVERALL, FOLLOW
the bottom, sides and back. Above joist area, STEPS 3, 4 AND 5.
materials.chimney must
h ave
y 1" clearance
s the topof
combustible
ibllthe 3. Lay out the 173/4"x 173/4" minimum opening on
the Ge
fireplace to the first joist are required a minimum keyholeeing. Cut out this area in ceiling with
saw. (If residential and overall height is
clearance of 3 inches. Firestop spacers MUST be above 16', use regular firestop spacer 141/2"x
installed at ceiling level. For Residential use, the 141/2" cutout).
8FSL Thimble (if used) must extend through the CAUTION: Take care to avoid cutting any wiring
first floor ceiling joists. At other floors, regular or plumbing above the ceiling. This opening will
firestop spacers may be used. They will provide be hidden by the fireplace framing.
the necessary clearance to the joists. Install the 4. Lay out and cut out same size opening in roof.
Fireplace no closer than is indicated in Fig. 1 to SUGGESTION: Drill upward from the four corners
any combustible wall perpendicular to the fire of the ceiling cutout, through the roof to locate
place openings, unless a Preway Wall Shield, the proper position for the roof cutout. ;
Model WS40 (or an equivalent approved by the 5. Frame in the minimum 173/4"x 173/4" hole o en-
local authority having jurisdiction over the installa- P
tion of the unit) is installed. This does not apply ing in roof and ceiling. NOTE: Check local codes.
to corner installation (See Fig. 8) or walls with Some codes will not allow cutting of roof trusses.
insulated shields (WS40). If so, the fireplace can only be installed in an out-
2. The installation will be easier and cost less if side chase on an outside wall or in homes with
roof trusses which are a minimum of 211/4" on
joists or rafters are not cut as the chimney is center. See Page 7 on chase construction.
assembled.
3. The fireplace may be installed directly on the floor, DOUBLE HEADERS NAILED IN PLACE
or an elevated wood or masonry platform may be
used. Be sure fireplace is on a solid continuous
floor or platform so no cold air can enter room
from under fireplace. 173/x" ♦ `', 173/4"
The fireplacerounmay betpositioned and b then the
fram-
ing built around it, or the framing may be constructed
and the fireplacepushed into the opening. •
P P 9• (Fig. 5.)
Location and Installation 111,\\, fj
7 0 _____>_z , ..44%. 7400.40001/ 11
FULL "r'
PROJECTION HOLE _j;- Vier
FOR
' CHIMNEY--
�
,
STUB JOISTS NAILED
,0.� FIG. 4 TO JOISTS
CORNER r • 0 FOR FLAT ROOF
INSTALLATION ONLY
FIG. 3 FLUSH To place headers in flat roof, mark a line parallel to
(CHASE INSTALLATION) opening in roof and ceiling on joists. Measure thick-
CAUTION ness of header back from this line. (Fig. 4.) ,,r,
Nail stub joist at each of these marks. Nail headers
If framing is to be inset from the sides of the to stub joists. If necessary, shims can be placed
between headers in same manner. (Fig. 4.) In some
fireplace above the fireplace then the chimney
spacers TSK8 must be attached before framing. cases hole may be cut near joist. In this case nail
shim directly to joist at side of opening.
4
installation
4" COMBUSTION AIR DUCT
ATTACH EACH SECTION TO FIREPLACE Framing
AND OUTSIDE VENT COVER ASSEMBLY HEADER
WITH 4" HOSE CLAMPS SUPPLIED I
USE DUCT TAPE AT EACH JOINT j 1 I I
I I,
TO BE SURE AIR TIGHT. i
(RECOMMENDED DUCT
BE INSULATED) I ` I
OUTSIDE UPWARD \ 1 STUDS
VENT THRU 24' i
COVER OUTSIDE I l REMOVE THESE
WALL SCREWS AND LIFT
AND REMOVE
FRONT GRILLE TO
HOSE i I
i I INSTALL BLOWER
r._,•-, CLAMP i I IIIIIIIII " "'llllllflll
1 i��r, I RECEPTACLE
1 ii I FOR USE
�.., '���{ ®111
WITH
-Ai - ; WITH
OUTSIDE .' BLOWER
VENT
COVER 010SIP _ ��'�WIRING
ACCESS
VIII PLATE
FLEXIBLE
THRU 4" DUCT ; IIIIIIIIIIlIIIlIIII 16"
OUTSIDE ` EXTENSION
HEARTH
WALL <\ ii,.--)"
1
DOWN THRU RECESS FRAMING PLACE METAL STRIP
FLOOR FOR THICKNESS OF UNDER FIREPLACE
FIG. 5 WALL OR FACING AND HEARTH EXTENSION
See Chart 2 for Dimensions
COMBUSTION AIR INLETS
There are two 4"diameter inlets, one on each side of for the combustion air duct. Be sure to extend 5"
the fireplace. Barometric dampers are installed in these openings all the way through to outside air source.
inlets automatically opening and closing them. Two 4" They must be through any insulation, vapor barrier, or
diameter flexible 42" long ducts are supplied to duct sheet metal to the outside of the home.
outside air to the fireplace. The combustion air ducts can Secure combustion air duct with screws. Push duct
be upward, downward, along side of fireplace or at the (with screen grill) through wall or floor from outside
rear (if the fireplace is on an outside wall). These and secure to duct attached to fireplace. Attach intake
barometric dampers allow the combustion air to be grill and outside vent cover to wall or flooring with
taken from any direction including above the fireplace. screws. Use duct tape on all joints to be sure they are
DO NOT TAKE AIR FROM ATTIC SPACE, ABOVE THE air tight.
ROOF, OR ANY OTHER ROOM, ESPECIALLY GARAGE. FIRESTOP
Do not take air from area where another fuel burning Position firestop or firestop/thimble in ceiling cutout
appliance is installed. and fasten securely to ceiling. The thimble must ex-
If the flexible duct is not long enough to extend to the tend upward through the upper part of the floor or
outside, it can be extended with any 4" diameter metal ceiling insulation. On a flat roof, or mobile home, it
pipe to any length needed. must extend up into the roof flashing. If it does not, a
thimble extension kit is available from your dealer or
When installing the combustion air ducts, attach to
fireplace and inlets firmly with hose clamps provided. an extension may be locally constructed from the same
Use duct tape on all joints to be sure they are air tight. gage material as the thimble and overlap the original,
(
It is recommended that these ducts be wrapped with one inch. Trim the thimble sleeve above the roof as
insulation to prevent condensation. required to allow flashing to fit flush on roof. On
residential, no shield is necessary above the thimble
See examples in Figs. 8, 9, 10 and 11. as 1" clearance to triple wall pipe is all that is required
Locate the outlets and cut 5" min. diameter holes in attic (or other) space above.
5
installation
FRAMING Electrical Code and all local codes and their require-
Frame in the fireplace enclosure and push fireplace ments. Have the wiring installed by a qualified person.
into it, or place fireplace in position and frame around NOTE: Speed control has White and Black wires, both
it. Place metal strip (provided) under fireplace and of which must be connected into hot line as shown in
extending out to where it will be under hearth ex- diagram.
tension also. This will prevent any sparks reaching HEARTH EXTENSION
the floor between fireplace and hearth extension. See
Chart 2 for width of hearth extension. The Hearth Extension must extend at least 16" in
Secure fireplace to floor with screws provided. front of and at least 8" beyond each side of the fire-
place opening. Use Preway Hearth Extension HE28,
IMPORTANT: For your safety and protection, the
HE28 1, for 28" and HE36, HE36-1 for 36" fireplace or
fireplace and chimney should be grounded. Use a
ground rod, clamp and wire to ground fireplace and /4" thick non-combustible insulating material with a
chimney. thermal conductivity of K=0.55 BTU/IN/HR/FT SQ °F.
This may be covered with non-combustible materials
ELECTRICAL which do not ignite and burn. Such materials consist
An electric junction box (with grounded receptacle) is of steel, iron, brick, tile, concrete, slate, asbestos, glass
located at the lower right, behind the bottom grill or plaster or any combination.
(Fig. 5). This is for use with the optional blower only CHIMNEY CHASES
(Page 15). The front of bottom grill may be removed,
for installation of the blower, by unscrewing three A chase is an enclosure for the fireplace and chim-
screws in grill (See Fig. 5). Electrical wiring connec- ney or multiple chimneys alone. It can start from the
tions may be made through the wiring access plate basement floor line, first floor, part way up the out-
without removal of receptacle or grill. side wall or on the roof itself.
Wire the receptacle into an electrical circuit during Consult local codes regarding height and construc-
the framing of the fireplace. A U.L. listed general use tion details in your area.
wall switch rated at 15 Amp. 125 VAC minimum may A chase should be constructed (and insulated) just
be used in the circuit or the speed control supplied as any other outside wall. The outside cover must
with blower. The fireplace junction box has a wiring be of a material designed for exterior use.
access plate next to the '/8" hole provided for connec-
tion of a electric wire fitting. Refer to wiring diagram FIRESTOP Chimney Enclosures
below. Locate the wall switch close to the fireplace in SPACER
a wall box. ) 04/
9 t
Installation of wiring must comply with the National t I J
ENCLOSURES SUPPORT
MUST BE TOP ELBOW —...ii ,41
90° TO THE WITH STRAPS I
FLOOR AND TO JOISTS 15° or 30°
CEILING Elbow
ON ALL
14/ .
FLOORS ABOVE
FIRST JOIST LEVEL
OPTIONAL BLOWER MIN.
WIRING DIAGRAM 1" MIN. '
4.
WHITE FIRESTOP
---I--
SPACER
I SPEED CONTROL 1.13.. ..45(
JUNCTION BOX :0 (SWITCH SUPPLIED /
IN FIREPLACE x WITH BLOWER)
IQ ti /
BLACK 1I03m —00"'.41--3" MIN.
(
l___J
OR CURCUIT BLACK TO FUSE / ZERO CLEARANCE
_
r WHITE BREAKER ENCLOSURESTO
WHITE . MUST BE SPACERTOP(TSK8)
FACTORY SUPPLIED 90° TO THE /
---- PID FLOOR ANDZERO
NOT SUPPLIED E ..
CEILING CLEARANCE
ON ALL TO TOP
NOTE: Speed control has White and Black FLOORS ABOVE SPACER'S
wires, both of which must be connected into FIRST JOIST
ZERO
hot line as shown in diagram. LEVEL .8--CLEARANCE
TO SIDES ,
,..1
CHASE FRAMING INSET FRAMING
FIG. 6
NOTE: Do not use more than four elbows per installation and never over 30°
maximum. Elbow may be mounted directly on fireplace.
6
installation
The fireplace chase must have the same insulation as cover the complete top to prevent water leakage. A
used in the house side walls. Many codes require a 6" high collar attached to this pan will keep the triple
closure at the first ceiling level with a firestop spacer wall pipe at its proper minimum height over pan. Use
installed. water proof caulking around all seams to be sure it is
The chase must be insulated up to a minimum of this weather tight. By constructing a chase in this fashion,
level (higher if more than one story) and also the the fireplace will be installed in a "warm" room and
cold air will be prevented from entering the home.
closure insulated with ceiling insulation.
through any portion of the fireplace.
The base of the chase must also be insulated be-
tween the solid continuous floor beneath the fireplace NOTE: The triple wall chimney pipe must extend
and the chase bottom. This will break the cold con- at least 6" above the chase top unless an 8CC chase
ductivity into the fireplace. cap is used.
A metal pan, made by local sheet metal shop, must
STUD O 8" ROUND
(JOISTS) TOP
INSULATE `o 1 TERMINATION
IN BETWEEN N.....00'
SAME AS STORM
CEILING 400 - COLLAR
14141441, 6" CHASE COLLAR
(
00/1
(135/s" DIA.)
\ CHASE
O METAL TOP
I �
<>:,,,
�SOLID
SURFACE
qi
��FIRESTOP P it
SPACER ``1� /
`T/
/014 0 I
,,,[j;„,,'
li 14'..
INSULATE
OUTSIDE
/
8 FOOT WALLS
CHASE COLLAR LEVEL BETWEEN
::.........
�- / STUDS
6' MIN. STORMR 4110 •
_t— ammmi
CHASE METAL I -o.l
TOP i
I I SOLID
CONTINUOUS
SURFACE
REFER TO PAGE 3 FORlir INSULATION
MINIMUM OVERALL HEIGHT (THERMAL
OF FIREPLACE TO FLUE OUTLET BARRIER)
MAY USE 8CC CHASE CAP OUTSIDE
WITH 8CCSA SPARK ARRESTOR \ BASE
FIG. 7
7
METHODS OF RUNNING COMBUSTION AIR DUCTS FOR ENERGY MIZER® SYSTEM
J SECOND FLOOR
OUTSIDE �, INSIDE g_ i 14---
_____.____._ 1
WALL , ROOM 8FS
FIRESTOP
SPACER
rftil DUCT
rI
EXTENDED
ri COMBUSTION TO MISS
AIR DUCT JOIST
rUP AND OVER1, OMNI U
C 0 Li I
iTOP OF
FIREPLACE TO OUTSIDE ,
WALL ALSO
•
I_I_ 1
45° Corner Installation on Slab Floor III
Wall, Inside Room) Basement or Crawl
Space Installation
FIG. 8 FIG. 10
CAUTION! Do Not Take Combustion Air
From Attic Space or Garage
PLATE
8RTSA d \____L
ROUND TOP
S
8FSL TO OTHER
FIRESTOP 0111101 SIDE AND SNOW 1,______ ---
SPACER DOWN THROUGH LEVEL ►
SOFFIT ,�� f_--
,, i _ i
INLET — I 'tea.
GRILLE GROUNDS -
IN LEVEL _
SOFFIT " LI [1 "
(OVER-
HANG) I `Th
BASEMENTi \:: --' 1_} •
' '• WALL
Concrete Slab Installation Basement Installation
(Under 16' Overall Height)
FIG. 9 FIG. 11
8
installation
Framing Dimensions FIG. 12 — 8RTSA TOP
RAIN CAP
� T
t .....-- ..._
CHIMNEY CAP ADAPTOR
A I} I f 3' MIN.
TO FLUE ■ TRIPLE WALL PIPE
I B � 0 p OUTLET LET MA� STORM COLLAR
7
E L , BFSL FLASHING
__:, _
�
ly J 7 - FIRESTOP
L. SPACER
4"DIA. T HF — (OVERALL
K _ UNDERHT 16')
G
A
INITEINIM1DAMPER
1
HANDLE
24"
% CLOSED —OPEN
INLET AIR
"_ ~ � DAMPER HANDLE
H
f [11
. ' FIG. 13
CHART 2
Dimensions 28", 36" Fireplace TO INSTALL CHIMNEY
CMODEL MODEL Chimney may be regular 8" triple wall pipe with
MEASUREMENT 6128 EM 6136 EM 8RTSA top, 8CC chase cap or complete 8DCT Decorative
A 14Y2"(SQ.) 141/2"(SQ.) Chimney. Refer to 8CC or 8DCT Manual for installa-
See Note(1) tion instructions.
B 15" 173/4" Position triple wall pipe on top of the fireplace.
C 21" 25" Match seam of triple wall pipe into notch of ring on
top of fireplace. Attach the pipe section to the fire-
D 231/2" 271/2" place with screws provided. If an offset is needed to
E 35" 39" miss a joist or rafter, use a 15° or 30° Elbow Kit.
F 16" 16" Mobile home installations of 12'6" and over may use
2 elbows. Residential installations of 16' and over may
G 35" 39" use 4 elbows. Do not angle pipe over 30°. (See Chart
See Note(3) on Page 16.)
H 21" 25" Maintain 1" minimum clearance to combustibles for
See Note(3) sections located above the joist area where the fire-
1 491/2" 551/2" place is located. Maintain 3" clearance to combustibles
See Note(3) for sections located directly above the fireplace. (See
Figure 6.)
See Note(3) 42" 50" Add additional sections of triple wall pipe until pipe
is 8" to 16" above roof. Screw sections of pipe to-
K 70" 78" gether with three screws provided.
See Note(3)
HEARTH x 16" 52"x 16" ON FLAT ROOF OR
EXTENSIONINIRESEMS
HOME
See Note(2) _ FTP SPACER
NOTES —i= > THIMBLE MUST EXTEND
1. Opening for chimney is 141/2" sq. for residential 8" TO ABOVE UPPERMOST SIDE
16" OF ROOF CUTOUT AND
installation over 16 ft., 173/4" sq. for mobile home INTO FLASHING. TRIM
Cinstallation or residential under 16 feet. SLEEVI AS REQUIRED
2. Los Angeles code requires Hearth to be 12" each TO SET FLASHING.
side of the Fireplace opening and 20" deep.
3. This dimension is for one elbow each side, point- FIG. 14
ing down. If more elbows are required, this
dimension will have to be increased.
9
installation
IF INSTALLED IN MOBILE HOME FINISHING
At this point it must not exceed 131/2' road clearance. The fireplace installation can be finished in an infi-
This will allow the top sections of the chimney to be nite variety of ways.
removed after completion, and permit moving the
mobile home on the highway. • DO NOT block off the air opening at the top or
bottom of the fireplace.
Pull flashing up and coat the area inside the mark- • Any mantel must be 12"or more above the fireplace
Ings with a good quality roof cement (not provided). top grille opening.
Push flashing down and press it firmly into the roof
cement. Fasten the flashing securely to the roof using
nails or screws. Coat the heads with roof cement.
Fasten the storm collar around the triple wall pipe a C A MANTEL
few inches above the flashing. Apply a bead of water- 12" MIN.
proof caulking (not provided) around the pipe, just A------A i,
above the flashing. Push the storm collar down on
the flashing. Apply caulking around the top of the
storm collar to seal it to the triple wall pipe. Illllllllllllla_...IIIIIIIIIIIII
I - I
A I = A
I I
B----4 4------B
I I
I r t I
PUSH DOWN--;41,_ IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII
11 4 FIG. 16
STORM I I
COLLAR .`J
CAULKINGNOTE
/ Do not allow any opening between the front of
FLASHING the fireplace and the surrounding materials. Cold
air may enter or hot air be lost if there is an
opening. Fill this area with non-combustible
FIG. 15 caulk or equal. Check with local codes for installa-
tion procedure.
A— Do not install combustible material closer than
line A.
Install the remaining sections of triple wall pipe until B — Do not install non-combustible material any closer
pipe with round top is 36" above roof. than 1/2" to line B for clearance for doors.
C — Non-combustible material can be installed up to
this line.
NOTE • For finishes using non-combustible facings, the
materials may overlap the frame of the fireplace
The Flue Outlet MUST be at least 3 feet above the up to within 1/2" of the opening on either side. It
roof surface top cutout and 2 feet above the should not extend below Line C above the fireplace
highest point within 10 feet horizontally (See opening. The finish materials may be anchored
Fig. 13). using metal screws into the fireplace frame.
• If triple wall pipe above the roof is to be painted,
paint it with galvanized primer and then paint
with color desired.
Install the Round Top Assembly. Set it on top of CAUTION
the triple wall pipe, align screw holes and secure with J
3 screws provided. All sections of pipe must be at- Do not block off the circulating air opening at
tached together with 3 screws to prevent any pipe the top or bottom front of the fireplace.
becoming loose.
10