Loading...
HomeMy WebLinkAboutCopies Request 2003 October 23, 2003 To: Town of Montville Connecticut Building Permit Office From: Charlene and Jerry DeFilippo RE: Blueprints of 100 Pruett Place, Oakdale CT 06370 As the owners of 100 Pruett Place, Oakdale, CT 06370 and requesting to have the blueprints of our house Turned over to us. Our house was being constructed in the summer of 2000. When we spoke you said they could be turned over to us because they were over 2 years old. Thank you Z-‘6(.A1-- ----c--• De 14 Charlene DeFilippo 860-437-0317 Subscribed and Sworn to before me, a Notar Public, in and for County of _ L„� Q. O1J and State of Connecticut, this ---- r i2 day of Notary Public Date Commission Expires. --.......................... LISA TERRY NOTARY PUBLIC MY COMMISSION EXPIRES OCT.31,2007 UNITED STATES POSTAL SERVICE® Receipt Amount(Written Out) Amount(In Numbers) /100 Dollars I$ Purpose /----07"(Ae(4. Is any Portion of this Sale a Charitable Tax Deduction? CJ 06382 fl � � • Yes '_ If"Yes,"the fair market value of the postage portion of the f. .i•. First-Class postage rat: F. `� qu- s t e By(Signature and - ��- � �l to PS Form 10'l•,April 1998 I return to sender fee due 50 First-Class Mail Postage and Fees Paid USPS Permit No. G-10 Town of 9tontvitte Bui(Giry1 Department Nur 310 Norwich-Ncw London Tp(c. I I Vrwasvi((e,Ct.06382 i l w U 5 N w � co J 111„„11„„11,1,„1,1.111.1 H CC Thomas Construction (n O 0.Box 144 U- pratnyw Ct TH 0(•11µ4 7+520O05 1N600 .10 06!13/00 ;THOM45 CONSTRUCTION 063 RDER BOX CLOSED UNABLE TO FORWARD (150- RETURN TO SENDER C5 =,T4/oi44 IIIA II II1.II,1IIwIlntlli„II IIII� SII SII �I 4442.4MG )e.•: 2.;./.3.3.3t ���!l1t11111l1�tl1} !lt�tllllEi'1�1lII�il�i11li�1!!! Permit Number MECcheck Compliance Report MECcheck Software Version 3.0 Release la Checked By/Date 1995 MEC Edition TITLE:THOMAS CONSTRUCTION CITY:Middletown STATE:Connecticut HDD:5945 CONSTRUCTION TYPE:Single Family DATE:07/12/00 PROJECT INFORMATION: 100 PRUETT COMPLIANCE:Passes Maximum UA=461 Your Home=430 6.7%Better Than Code Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA Ceiling 1:All-Wood Joist/Rafter/Truss 1080 30.0 30.0 18 Exterior Wall 1:Wood Frame, 16"o.c. 1184 19.0 19.0 40 Exterior Wall 2:Wood Frame, 16"o.c. 1040 19M 19.0 35 Basement Wall 1: Solid Concrete or Masonry 1005 0.5 0.5 244 Window 1:Vinyl Frame,Double Pane 112 0.170 19 Window 2:Vinyl Frame,Double Pane 124 0.170 21 Door 1:Other 63 - 0.100 6 Floor 1:All-Wood Joist/Truss,Over Unconditioned Space 1170 11.0 11.0 47 Boiler 1:Other(Exept Gas-Fired Steam)), 80 AFUE Air Conditioner 1: Electric Central Air, 10 SEER COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans,specifications,and other calculati. s submitted with the permit application. The proposed building has z„,been designed to meet the 19 -' C;:.u'ini ents in MECcheck Version 3.0 Release Ia. Builder/Designer lz, "/4019M Date 7/5"/OD • MECcheck Inspection Checklist MECcheck Software Version 3.0 Release la 1995 MEC Edition DATE:07/12/00 TITLE:THOMAS CONSTRUCTION Bldg. 1 Dept. Use Roofs: [] 1. Ceiling 1:All-Wood Joist/Rafter/Truss,R-30.0 cavity+R-30.0 continuous insulation Comments/Location g Above-Grade Walls: [] 1. Exterior Wall 1: Wood Frame, 16"o.c.,R-19.0 cavity+R-19.0 continuous insulation Comments/Location [] 2. Exterior Wall 2:Wood Frame, 16"o.c.,R-19.0 cavity+R-19.0 continuous insulation Comments/Location Basement Walls: fl 1. Basement Wall 1: Solid Concrete or Masonry,7.5'ht/5.0'bg/0.0'insul, R-0.5 cavity+R-0.5 continuous insulation Comments/Location Windows: fl 1. Window 1:Vinyl Frame,Double Pane,U-factor:0.170 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?[j Yes[j No Comments/Location fl 2. Window 2: Vinyl Frame,Double Pane,U factor:0.170 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?[]Yes[1 No Comments/Location Doors: [] 1. Door 1:Other,U-factor:0.100 Comments/Location Floors: [] 1. Floor 1:All-Wood Joist/Truss,Over Unconditioned Space, R-11.0 cavity+R-11.0 continuous insulation Comments/Location Heating and Cooling Equipment: [] 1. Boiler 1:Other(Exept Gas-Fired Steam)),80 AFUE or higher Make and Model Number [] 2. Air Conditioner 1:Electric Central Air, 10 SEER or higher Make and Model Number Air Leakage: [1 Joints,penetrations,and all other such openings in the building envelope that are sources of air leakage must be sealed. [] Recessed lights must be type IC rated and installed with no penetrations or installed inside an appropriate air-tight assembly with a 0.5"clearance from combustible materials and 3"clearance from insulation. Vapor Retarder: [] Required on the warm-in-winter side of all non-vented framed ceilings,walls,and floors. Materials Identification: [] Materials and equipment must be identified so that compliance can be determined. [] Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. [] Insulation R-values and glazing U-values must be clearly marked on the building plans or specifications. Duct Insulation: [] Ducts in unconditioned spaces must be insulated to R-5. Ducts outside the building must be insulated to R-6.5. Duct Construction: [] All ducts must be sealed with mastic and fibrous backing tape. Pressure-sensitive tape may be used for fibrous ducts. Duct tape is not permitted. [] The HVAC system must provide a means for bancing air and water systems. Temperature Controls: [] Thermostats are required for each separate HVAC system. A manual or automatic means to partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided. Circulating Hot Water Systems: [] Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: [] All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: [] HVAC piping conveying fluids above 120 °F or chilled fluids below 55°F must be insulated to the levels in Table 2. Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by Pipe Sizes Heated Water Non-Circulating Runouts Circulating Mains and Runouts Temperature(F) Up to 1" Up to 1.25" 1.5"to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes. Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System T}Pes Range(F) 2"Runouts 1"and Less 1.25"to 2" 2.5"to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water,Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD(Building Department Use Only) BOISE CASCADE - BC CALCTM 2000 DESIGN REPORT - US Monday,July 10,2000 16:40 Triple - 1 3/4" x 11 7/8" V-L SP 2900 File Name: Untitled Job Name - Customer - NORWICH LUMBER CO. Address - Specifier - Designer - Valued Employee City,State,Zip - Company: - Wood Structures Inc. Code Reports - ICBO 5512, BOCA 98-52,SBCCI 9852 Misc: - Member Diagram BEAM 'A' - I I 1� i L -. __ 1__ -L_ Standard Load-40 PSF 117 PSF Tributary 13-00-00 A A 1- mommomom .................. ... .. .:..::::....:.....:..:::..::.,.....r; :;•x....•:::...< <. .<.�f:: .:. .......<.i....::::....:... :...•.. /: : : /F.... m:::jf ..rMf , . :f ... ft .u.::.t.:::•.;u....:l•.} g.:.:ru{a.•} 3640 lbs LL 1670 lbs DL 3640 lbs LL 1670 lbs DL Total Horizontal Length-14-00-00 General Data Load Summary Version: US Imperial ID Description Load Type Ref. Start End Live Dead Trib. Dur. S Standard Unf.Area Load Left 00-00-00 14-00-00 40 PSF 17 PSF 13-00-00 115 Member Type: - Floor Beam Number of Spans - 1 Controls Summary Left Cantilever - No Control Type Value %Allowable Duration Loadcase Span Location Right Cantilever - No Moment 18584 ft-lbs 54.1% @ 115% 2 1 -Internal End Shear 4559 lbs 32.9% @ 115% 2 1 -Right Slope 0/12 Total Deflection L/375(0.447") 63.9% 2 1 Tributary 13-00-00 Live Deflection L/547(0.307) 65.7% 2 1 Repetitive n/a Max. Deft. 0.447(Limit: 1") 44.7% 2 1 Construction Type n/a Span/Depth 14.1 1 Live Load 40 PSF Dead Load 17 PSF NOTES: Part Load 0 PSF Design meets Code minimum(L/240)Total load deflection criteria. Duration 115 Design meets Code minimum(L/360)Live load deflection criteria. Design meets arbitrary(1")Maximum load deflection criteria. Disclosure Minimum End bearing length is 1-1/2". The completeness and accuracy of the input must be verified by anyone who would rely on the output as evidence of suitability for a particular application. The output above is based upon building code-accepted design properties and analysis methods. Installation of Boise Cascade engineered wood products must be in accordance with the current Installation Guide and the applicable building codes. To obtain an Installation Guide or if you have any questions,please call (800)232-0788 before beginning product installation. For glulam inquiries,please call(800)237-4013. Page 1 of 1 BCI®and Versa-Lam®are registered trademarks of Boise Cascade Corp. BOISE CASCADE - BC CALCTM 2000 DESIGN REPORT - US Monday,July 10,2000 16:41 Triple - 1 3/4" x 9 1/4" V-L SP 2900 File Job Name Name: Untitled Address Customer - NORWICH LUMBER CO. Specifier - Designer - Valued Employee City,State,Zip - Code Reports - ICBO 5512, BOCA 98-52,SBCCI 9852 M scComPany - Wood Structures Inc. Member Diagram BEAM 'B' I l 1 i I I 1 Standard Load-40 PSF 110 PSF Tributary 07-00-00 I I ..::•{ :....... ..:-.:.i::{:•?f{.;o,;r;;:::ii:2i::.:•....;:rrr:::.,••f.•:r: {.:?{r:::.::::::::rr::::r:r..:... ...:•:•:..:.•.•...:::.......::::::::::::::::.......................... ??•if• :::..:::::•:... r : .rrr ...................... ..........................:...r....:....:....::.:..... ....................................:......................... G::f'•:;:;•:>+.;•.;•.:: ?,;.:.;;::;.;•::.:;:•;:•::..;.;•.:::::•:::fry: :r,< .r..... .................f. .:..:.rr...r.... ............ ... ................... .:.. ..pr:?.. . .f... V*i:i?:i*i:i ... V:*i:::::;..........i*i: ....::.:M:i:*i:i: ..:i:N::::::.....ri%::.....::f..;:r.........n..r:...::x;;...... ...::N*:..................... ..x.+r.x.r....r.r..::..rrr...xr+.r..m:•.wr•?x;?ri,?�Y/rr rr rrr n.:r:x:x::u: .r.............:.........:.:::.::::::..... .......:•.: ..........::::::::.�:.�.............::?•x:rr??.;;:.:......::::::: ...... ........:n:.r.:: ::..:r::::::.:::: :::::............... �..L.;................r?r{{<{{r:..rxr+rvr:m•rrr:..:w::... .....r:r:u..x+.rr.r...rrr::.::::..........:....::w•......:......:::::::...............r?w:.�. • :.......r......:::.y:.:.::...... •...... ................:.... ::::::::f: :::::r.:::itf.rff.}?;:;+f.?:w???xrxrffffrm�rr�irrr fiii'ff.r....r.:rf{.•ii:'`%?r:Y{:•:::......;;;; �?:::f?.i:f ....: : : r.{f...n...:: :r:r i..:ir::::?:%,?;?<::lf.!f{r f{.•ir+.•:: ifffr;?i:i.F:?:? •:Mj:::: 1960 lbs LL 586 lbs DL 1960 lbs LL I 586 lbs DL Total Horizontal Length-14-00-00 General Data Load Summary Version: US Imperial ID Description Load Type Ref. Start End Live Dead Trib. Dur. S Standard Unf.Area Load Left 00-00-00 14-00-00 40 PSF 10 PSF 07-00-00 100 Member Type: - Floor Beam Number of Spans - 1 Controls Summary Left Cantilever - No Control Type Value Right Cantilever - No Moment 8910 ft-lbs /47..8 Allowable @100% LoadcaseDuration SSpan Location End Shear 2265 lbs 24.1% @ 100% 2 1 -Left rnal Slope 0/12 Total Deflection L/370(0.454") 64.8% 2 1 Tributary 07-00-00 Live Deflection U480(0.349") 74.9% 2 1 Repetitive n/a Max.Defl. 0.454"(Limit: 1") 45.4% 2 1 Construction Type n/a Span/Depth 18.2 1 Live Load 40 PSF Dead Load 10 PSF NOTES: Part Load 0 PSF Design meets Code minimum(U240)Total load deflection criteria. Duration 100 Design meets Code minimum(11360)Live load deflection criteria. Design meets arbitrary(1")Maximum load deflection criteria. Disclosure Minimum End bearing length is 1-10. The completeness and accuracy of the input must be verified by anyone who would rely on the output as evidence of suitability for a particular application. The output above is based upon building code-accepted design properties and analysis methods. Installation of Boise Cascade engineered wood products must be in accordance with the current Installation Guide and the applicable building codes. To obtain an Installation Guide or if you have any questions,please call (800)232-0788 before beginning product installation. For glulam inquiries,please call(800)237-4013. Page 1 of 1 BCI®and Versa-Lam®are registered trademarks of Boise Cascade Corp. BOISE CASCADE - BC CALCTM 2000 DESIGN REPORT - US Monday,July 10,2000 16:42 Double - 1 3/4" x 11 7/8" V-L SP 2900 Name: Job Name - Untitled Customer - NORWICH LUMBER CO. Address Specifier - File Designer - Valued Employee City,State,Zip - Company: - Wood Structures Inc. Code Reports - ICBO 5512,BOCA 98-52,SBCCI 9852 Misc: - • Member Diagram BEAM 'C' L 1- i Standard Load-40 PSF 120 PSF Tributary 09-00-00 _ ::............. :i:Ki.:.f.•.vx;........ .........:.:.::::x•.. ..... ..:l:w•:;....mi:i.. i:i:i.:.:xx:..... ......:i::.::....;...n...x.....n.iai:i:::mi:i:.................:h:*i:i:i........... .•.. . .. ...... .....:......:... ....... r..x....v;y.x...r...:..r:::;•::w;;....... ::..ff..v.v:.r.......rrrf.:x+r.�l .• ...........:::. w:w;;..................::::::::::: '..,. ..................:.:::...:....... l......;,{err:y,! r.n.±.;:....V::•:.:..;:.;;::::•. :::::::::x::r::. . ... ::: ... ...........:........:..}:::.v:':::?::::::::... n...... { Fj;:?:p:�•.f:•:•iii$r?:�$rryxr???F??•fi:?•:4:^f::4::.{{{.:..?:n:r?:.n:.:•:xl::::m::l:r: • . ':'::' lbs LL 25201342lbs DL 2520 lbs LL 1342 lbs DL Total Horizontal Length-14-00-00 General Data Load Summary Version: US Imperial ID Description Load Type Ref. Start End Live Dead Trib. Dur. S Standard Unf.Area Load Left 00-00-00 14-00-00 40 PSF 20 PSF 09-00-00 100 Member Type. - Floor Beam Number of Spans - 1 Controls Summary Left Cantilever - No Control Type Value %Allowable Duration Loadcase Span Location Right Cantilever - No Moment 13516 ft-lbs 67.9% @ 100% 2 1 -Internal End Shear 3316 lbs 41.3% @ 100% 2 1 -Left Slope 0/12 Total Deflection L/344(0.488") 69.7% 2 1 Tributary 09-00-00 Live Deflection L/527(0.319") 68.3% 2 1 Repetitive n/a Max. Defl. 0.488"(Limit: 1") 48.8% 2 1 Construction Type n/a Span/Depth 14.1 1 Live Load 40 PSF Dead Load 20 PSF NOTES: Part Load 0 PSF Design meets Code minimum(L/240)Total load deflection criteria. Duration 100 Design meets Code minimum(L/360)Live load deflection criteria. Design meets arbitrary(1")Maximum load deflection criteria. Disclosure Minimum End bearing length is 1-1/2". The completeness and accuracy of the input must be verified by anyone who would rely on the output as evidence of suitability for a particular application. The output above is based upon building code-accepted design properties and analysis methods. Installation of Boise Cascade engineered wood products must be in accordance with the current Installation Guide and the applicable building codes. To obtain an Installation Guide or if you have any questions,please call (800)232-0788 before beginning product installation. For glulam inquiries,please call(800)237-4013. Page 1 of 1 BCI®and Versa-Lam®are registered trademarks of Boise Cascade Corp. BOISE CASCADE - BC CALCTM 2000 DESIGN REPORT - US Monday,July 10,2000 16:44 Triple - 1 3/4" x 14" V-L SP 2900 Name: Untitled Job NameCustomer - NORWICH LUMBER CO. Address Specifier - File Designer - Valued Employee City,State,Zip - Company: - Wood Structures Inc. Code Reports - ICBO 5512,BOCA 98-52,SBCCI 9852 Misc: - Member Diagram BEAM 'D' 2 1 1 Standard Load-40 PSF 120 PSF Tributary 13-00-00 1 - I I 1 ...r...f Grf frrr..:fr:• :n:::::r::•.::rrr:?.:.........:::...:?v1?•:r•::::::::.?..,...........:::::::::::::::::.�:.�::::::.:: ::::::::::::•:? . ::. .:.:,.::•::x.x.:r•:•:.�:.••:.�r:::.........,.�::•:•::;;?;•::•:r•:::.:::.• :::::. f.rt ...0 r.r........ ......::::A:.. is :............ .... ....�/.,... ......r{.'. ........,:,t•::r.?.:.:.............r.rrr.............fnr;f.:r..::...:::::::::::::::::::.�:::::::::::•. ::::::::::::::•::•:::::;:••• «:+.rrr.r.... f. /.:r : r«.r: .. .. . r.. ........f. ... ... f:�rrr« : ...............m:«:+ ....r r?r::rr «rr:.: rx.r r«r..r.;r ..n.....v•. f .r«:«:::•ii}ih:?U: .ter.?:?•:. . : i :v:::::;i::v:.:�?y::S;::?•i;},::r................G::+• :? ?•::::::.�::::......... r.rr r rr «: .r.x:..rr.«::.r .........f .:.::.....:::... .:.:.:....:.:.:.::...:.::::.::...:...:/........:.....::<:??r{{{{ff,r.'.::::{{{{/{,.{.S�•`•: � f ff !Ff. f{.,;.5?<a?+r. ?err:ffff�rrr,:,...fnfffr?rf. 7280 lbs LL ....:.:... .......:...?...::::.:..:::......:.:. 37157280 lbs DL 7280 lbs LL - - - 3715 lbs DL Total Horizontal Length-14-00-00 General Data Load Summary Version: US Imperial ID Description Load Type Ref. Start End Live Dead Trib. Dur. S Standard Unf.Area Load Left 00-00-00 14-00-00 40 PSF 20 PSF 13-00-00 100 Member Type: - Floor Beam 1 Unf.Lin. Load Left 00-00-00 14-00-00 0 PLF 120 PLF n/a 100 Number of Spans - 1 2 Unf.Lin. Load Left 00-00-00 14-00-00 520 PLF 130 PLF n/a 100 Left Cantilever - No Right Cantilever - No Controls Summary Control Type Value %Allowable Duration Loadcase Span Location Slope 0/12 Moment 38481 ft-lbs 94.5% @ 100% 2 1 -Internal Tributary 13-00-00 End Shear 9162 lbs 64.5% @ 100% 2 1 -Left Repetitive n/a Total Deflection L/297(0.565") 80.8% 2 1 Construction Type n/a Live Deflection L/448(0.374") 80.2% 2 1 Max. Defl. 0.565"(Limit: 1") 56.5% 2 1 Live Load 40 PSF Span/Depth 12.0 1 Dead Load 20 PSF Part Load 0 PSF Duration 100 NOTES: Design meets Code minimum(L/240)Total load deflection criteria. Disclosure Design meets Code minimum(L/360)Live load deflection criteria. The completeness and accuracy of Design meets arbitrary(1")Maximum load deflection criteria. the input must be verified by anyone Minimum End bearing length is 2-1/2". who would rely on the output as evidence of suitability for a particular application. The output above is based upon building code-accepted design properties and analysis methods. Installation of Boise Cascade engineered wood products must be in accordance with the current Installation Guide and the applicable building codes. To obtain an Installation Guide or if you have any questions,please call (800)232-0788 before beginning product installation. For glulam inquiries,please call(800)237-4013. Page 1 of 1 BCI®and Versa-Lam®are registered trademarks of Boise Cascade Corp. CALC/PLUS COMPUTER GENERATED HEAT LOSS/GAIN CALCULATION Copyright (C) 1987-1991 by Edward Horgan, Horgan Vertical Applications Company RD # 9 - Box 273, Coatesville, PA 19320 (215) 384-1923 DESIGN: WINTER, 70 DEG DIFFERENCE - SUMMER, 20 DEG DIFFERENCE, 90 DEG OUTSIDE JOB: ' - RESIDENTIAL CALCULATION 05-03-2000 I BASEMENT - UNHEATED NO LOSS OR GAIN LAUNDRY RM - MAIN LEVEL, NORTH & EAST AREA LOSS GAIN HARDWOOD FLOOR R11 INS OVER UNHEATED BASEMENT OR ENCLOSED 78 218 0 EXPOSED WALL 12 X 8 (FT) , FRAME OR VENEER, R19 INSULATION 96 403 163 1 WINDOW 24 X 36 (IN) , DOUBLE GLASS, NO SHADE IN OR OUT 6 243 426 EXPOSED WALL 6 .5 X 8 (FT) , FRAME OR VENEER, R19 INSULATION 46 193 78 ALLOWANCE FOR INFILTRATION - MEDIUM CONSTRUCTION 78 873 117 ALLOWANCE FOR LATENT HEAT 78 0 235 FOR WARM AIR HEATING SYSTEM OR AIR CONDITIONING: REQUIRES: 1 BRANCH DUCT (5 IN ROUND) (5 IN OVAL) OR (3-1/4 X 8 WALL STACK) REQUIRES : 1 #661 6 X 4 SIDEWALL REGISTER OR 1 #411 2-1/4 X 10 FLOOR DIFFUSER OR 1 #16 6 IN ROUND CEILING DIFFUSER OR 1 #24 6 X 6 SQUARE DIFFUSER REQUIRES: 1 #650 10 X 6 RETURN AIR GRILL OR 1 # 659 20 X 14 FILTER GRILL FOR HOT WATER HEATING SYSTEM WITH BASEBOARD 560 BTU AT 180 DEGREES : REQUIRED HYDRONIC BASEBOARD FOR THIS ROOM IS 4 FEET REQUIRED END CAPS ESTIMATED FOR THIS ROOM IS 2 TOTAL TOTAL REQUIRED CFM AND TOTAL BTU HEAT LOSS/GAIN CFM LOSS GAIN CFM AT RECOMMENDED MAXIMUM VELOCITY OF 600 FPM 34 1930 1019 BATH RM # 1 - MAIN LEVEL, EAST AREA LOSS GAIN 1 WINDOW 24 X 36 (IN) , DOUBLE GLASS, NO SHADE IN OR OUT 6 243 426 HARDWOOD FLOOR R11 INS OVER UNHEATED BASEMENT OR ENCLOSED 40 111 0 EXPOSED WALL 5 .5 X 8 (FT) , FRAME OR VENEER, R19 INSULATION 38 159 64 ALLOWANCE FOR INFILTRATION - MEDIUM CONSTRUCTION 40 447 60 ALLOWANCE FOR LATENT HEAT 40 0 165 ALLOWANCE FOR BATHROOM COMFORT 40 192 0 FOR WARM AIR HEATING SYSTEM OR AIR CONDITIONING: REQUIRES : 1 BRANCH DUCT (5 IN ROUND) (5 IN OVAL) OR (3-1/4 X 8 WALL STACK) REQUIRES: 1 #661 6 X 4 SIDEWALL REGISTER OR 1 #411 2-1/4 X 10 FLOOR DIFFUSER OR 1 #16 6 IN ROUND CEILING DIFFUSER OR 1 #24 6 X 6 SQUARE DIFFUSER REQUIRES : 1 #650 10 X 6 RETURN AIR GRILL OR 1 # 659 20 X 14 FILTER GRILL FOR HOT WATER HEATING SYSTEM WITH BASEBOARD 560 BTU AT 180 DEGREES : REQUIRED HYDRONIC BASEBOARD FOR THIS ROOM IS 3 FEET REQUIRED END CAPS ESTIMATED FOR THIS ROOM IS 2 TOTAL TOTAL REQUIRED CFM AND TOTAL BTU HEAT LOSS/GAIN CFM LOSS GAI'. CFM AT RECOMMENDED MAXIMUM VELOCITY OF 600 FPM 24 1152 7] KITCHEN - MAIN LEVEL, EAST AREA LOSS G- 1 WINDOW 24 X 48 (IN) , DOUBLE GLASS, NO SHADE IN OR OUT 8 324 568 1 DOOR 72 X 80 (IN) , WOOD WITHOUT STORM DOOR 40 HARDWOOD FLOOR R11 INS OVER UNHEATED BASEMENT OR ENCLOSED 264 1739 444372 0 EXPOSED WALL 22 X 8 (FT) , FRAME OR VENEER, R19 INSULATION 128 537 217 ALLOWANCE FOR INFILTRATION — MEDIUM CONSTRUCTION 264 2956 396 ALLOWANCE FOR LATENT HEAT 264 0 487 ALLOWANCE FOR APPLIANCES AND MOTORS 264 0 1200 FOR WARM AIR HEATING SYSTEM OR AIR CONDITIONING: REQUIRES : 2 BRANCH DUCT (5 IN ROUND) (5 IN OVAL) OR (3-1/4 X 8 WALL STACK) REQUIRES : 2 #661 10 X 4 SIDEWALL REGISTER OR 2 #411 2-1/4 X14 FLOOR DIFFUSER OR 2 #16 6 IN ROUND CEILING DIFFUSER OR 2 #24 6 X 6 SQUARE DIFFUSER REQUIRES : 1 #650 10 X 6 RETURN AIR GRILL OR 1 # 659 20 X 14 FILTER GRILL FOR HOT WATER HEATING SYSTEM WITH BASEBOARD 560 BTU AT 180 DEGREES : a REQUIRED HYDRONIC BASEBOARD FOR THIS ROOM IS 11 FEET REQUIRED END CAPS ESTIMATED FOR THIS ROOM IS 2 TOTAL TOTAL REQUIRED CFM AND TOTAL BTU HEAT LOSS/GAIN CFM LOSS GAIN CFM AT RECOMMENDED MAXIMUM VELOCITY OF 600 FPM 112 5928 3312 DINING ROOM — MAIN LEVEL, EAST & SOUTH AREA LOSS GAIN 2 WINDOWS 36 X 60 (IN) , DOUBLE GLASS, NO SHADE IN OR OUT 30 1218 2130 HARDWOOD FLOOR R11 INS OVER UNHEATED BASEMENT OR ENCLOSED 196 548 0 EXPOSED WALL 14 X 8 (FT) , FRAME OR VENEER, R19 INSULATION 82 344 139 EXPOSED WALL 14 X 8 (FT) , FRAME OR VENEER, R19 INSULATION 112 470 190 ALLOWANCE FOR INFILTRATION — MEDIUM CONSTRUCTION 196 2195 294 ALLOWANCE FOR LATENT HEAT 196 0 825 FOR WARM AIR HEATING SYSTEM OR AIR CONDITIONING: REQUIRES: 2 BRANCH DUCT (5 IN ROUND) (5 IN OVAL) OR (3-1/4 X 8 WALL STACK) REQUIRES: 2 #661 10 X 4 SIDEWALL REGISTER OR 2 #411 2-1/4 X14 FLOOR DIFFUSER OR 2 #16 6 IN ROUND CEILING DIFFUSER OR 2 #24 6 X 6 SQUARE DIFFUSER REQUIRES : 1 #650 10 X 6 RETURN AIR GRILL OR 1 # 659 20 X 14 FILTER GRILL FOR HOT WATER HEATING SYSTEM WITH BASEBOARD 560 BTU AT 180 DEGREES : REQUIRED HYDRONIC BASEBOARD FOR THIS ROOM IS 9 FEET REQUIRED END CAPS ESTIMATED FOR THIS ROOM IS 2 TOTAL TOTAL REQUIRED CFM AND TOTAL BTU HEAT LOSS/GAIN CFM LOSS GAIN CFM AT RECOMMENDED MAXIMUM VELOCITY OF 600 FPM 121 4775 3578 LIVING ROOM — MAIN LEVEL, SOUTH & WEST AREA LOSS GAIN CARPETED FLOOR R11 INS OVER UNHEATED BASEMENT OR ENCLOSED 175 437 0 EXPOSED WALL 12 .5 X 8 (FT) , FRAME OR VENEER, R19 INSULATION 100 419 170 2 WINDOWS 36 X 60 (IN) , DOUBLE GLASS, NO SHADE IN OR OUT 30 1218 2130 EXPOSED WALL 14 X 8 (FT) , FRAME OR VENEER, R19 INSULATION 82 344 139 ALLOWANCE FOR INFILTRATION — MEDIUM CONSTRUCTION 175 1959 262 ALLOWANCE FOR LATENT HEAT 175 0 810 FOR WARM AIR HEATING SYSTEM OR AIR CONDITIONING: REQUIRES : 2 BRANCH DUCT (5 IN ROUND) (5 IN OVAL) OR (3-1/4 X 8 WALL STACK) REQUIRES : 2 #661 10 X 4 SIDEWALL REGISTER OR 2 #411 2-1/4 X14 FLOOR DIFFUSER OR 2 #16 6 IN ROUND CEILING DIFFUSER OR 2 #24 6 X 6 SQUARE DIFFUSER REQUIRES : 1 #650 10 X 6 RETURN AIR GRILL OR 1 # 659 20 X 14 FILTER GRILL FOR HOT WATER HEATING SYSTEM WITH BASEBOARD 560 BTU AT 180 DEGREES : REQUIRED HYDRONIC BASEBOARD FOR THIS ROOM IS 8 FEET REQUIRED END CAPS ESTIMATED FOR THIS ROOM IS 2 TOTAL TOTAL REQUIRED CFM AND TOTAL BTU HEAT LOSS/GAIN CFM LOSS GAIN CFM AT RECOMMENDED MAXIMUM VELOCITY OF 600 FPM 119 4377 3511 FOYER - MAIN LEVEL, WEST AREA LOSS GAIN 1 DOOR 36 X 80 (IN) , METAL INSULATED NO STORM 20 266 84 HARDWOOD FLOOR R11 INS OVER UNHEATED BASEMENT OR ENCLOSED 140 391 0 EXPOSED WALL 10 X 8 (FT) , FRAME OR VENEER, R19 INSULATION 60 251 102 ALLOWANCE FOR INFILTRATION - MEDIUM CONSTRUCTION 140 1567 210 ALLOWANCE FOR LATENT HEAT 140 0 118 FOR WARM AIR HEATING SYSTEM OR AIR CONDITIONING: REQUIRES : 1 BRANCH DUCT (5 IN ROUND) (5 IN OVAL) OR (3-1/4 X 8 WALL STACK) REQUIRES: 1 #661 6 X 4 SIDEWALL REGISTER OR 1 #411 2-1/4 X 10 FLOOR DIFFUSER OR 1 #16 6 IN ROUND CEILING DIFFUSER OR 1 #24 6 X 6 SQUARE DIFFUSER REQUIRES: 1 #650 10 X 6 RETURN AIR GRILL OR 1 # 659 20 X 14 FILTER GRILL FOR HOT WATER HEATING SYSTEM WITH BASEBOARD 560 BTU AT 180 DEGREES : REQUIRED HYDRONIC BASEBOARD FOR THIS ROOM IS 5 FEET REQUIRED END CAPS ESTIMATED FOR THIS ROOM IS 2 TOTAL TOTAL REQUIRED CFM AND TOTAL BTU HEAT LOSS/GAIN CFM LOSS GAIN CFM AT RECOMMENDED MAXIMUM VELOCITY OF 600 FPM 34 2475 514 OFFICE - MAIN LEVEL, WEST AREA LOSS GAIN 2 WINDOWS 36 X 60 (IN) , DOUBLE GLASS, NO SHADE IN OR OUT 30 1218 2130 CARPETED FLOOR R11 INS OVER UNHEATED BASEMENT OR ENCLOSED 138 345 0 PARTITION WALL 14 X 8 (FT) , R19 (6 INCH) INSULATION 112 358 78 EXPOSED WALL 14 X 8 (FT) , FRAME OR VENEER, R19 INSULATION 82 344 139 ALLOWANCE FOR INFILTRATION - MEDIUM CONSTRUCTION 138 1545 207 ALLOWANCE FOR LATENT HEAT 138 0 766 FOR WARM AIR HEATING SYSTEM OR AIR CONDITIONING: REQUIRES: 2 BRANCH DUCT (5 IN ROUND) (5 IN OVAL) OR (3-1/4 X 8 WALL STACK) REQUIRES : 2 #661 10 X 4 SIDEWALL REGISTER OR 2 #411 2-1/4 X14 FLOOR DIFFUSER OR 2 #16 6 IN ROUND CEILING DIFFUSER OR 2 #24 6 X 6 SQUARE DIFFUSER REQUIRES : 1 #650 10 X 6 RETURN AIR GRILL OR 1 # 659 20 X 14 FILTER GRILL FOR HOT WATER HEATING SYSTEM WITH BASEBOARD 560 BTU AT 180 DEGREES : REQUIRED HYDRONIC BASEBOARD FOR THIS ROOM IS 7 FEET REQUIRED END CAPS ESTIMATED FOR THIS ROOM IS 2 TOTAL TOTAL REQUIRED CFM AND TOTAL BTU HEAT LOSS/GAIN CFM LOSS GAIN CFM AT RECOMMENDED MAXIMUM VELOCITY OF 600 FPM 112 3810 3320 BED ROOM # 2 - LEVEL TWO, NORTH & EAST AREA LOSS GAIN 1 WINDOW 36 X 60 (IN) , DOUBLE GLASS, NO SHADE IN OR OUT 15 609 330 CEILINGS UNDER VENTILATED ATTIC, R30 INSULATION 156 358 249 FLOOR OVER CONDITIONED SPACE - NO LOSS OR GAIN 0 0 0 EXPOSED WALL 12 X 8 (FT) , FRAME OR VENEER, R19 INSULATION 81 340 137 2 WINDOWS 36 X 60 (IN) , DOUBLE GLASS, NO SHADE IN OR OUT 30 1218 2130 EXPOSED WALL 13 X 8 (FT) , FRAME OR VENEER, R19 INSULATION 74 310 125 ALLOWANCE FOR INFILTRATION - MEDIUM CONSTRUCTION ALLOWANCE FOR LATENT HEAT 156 1747 234 156 0 961 FOR WARM AIR HEATING SYSTEM OR AIR CONDITIONING: REQUIRES: 2 BRANCH DUCT (5 IN ROUND) (5 IN OVAL) OR (3-1/4 X 8 WALL STACK) REQUIRES: 2 #661 10 X 4 SIDEWALL REGISTER OR 2 #411 2-1/4 X14 FLOOR DIFFUSER OR 2 #16 6 IN ROUND CEILING DIFFUSER OR 2 #24 6 X 6 SQUARE DIFFUSER REQUIRES: 1 #650 10 X 6 RETURN AIR GRILL OR 1 # 659 20 X 14 FILTER GRILL FOR HOT WATER HEATING SYSTEM WITH BASEBOARD 560 BTU AT 180 DEGREES : REQUIRED HYDRONIC BASEBOARD FOR THIS ROOM IS 9 FEET REQUIRED END CAPS ESTIMATED FOR THIS ROOM IS 2 TOTAL TOTAL REQUIRED CFM AND TOTAL BTU HEAT LOSS/GAIN CFM LOSS GAIN CFM AT RECOMMENDED MAXIMUM VELOCITY OF 600 FPM 141 4582 4166 BATH RM # 2 - LEVEL TWO, EAST AREA LOSS GAIN 1 WINDOW 24 X 36 (IN) , DOUBLE GLASS, NO SHADE IN OR OUT 6 243 426 CEILINGS UNDER VENTILATED ATTIC, R30 INSULATION 72 165 115 FLOOR OVER CONDITIONED SPACE - NO LOSS OR GAIN 0 0 0 EXPOSED WALL 8 X 8 (FT) , FRAME OR VENEER, R19 INSULATION 58 243 98 ALLOWANCE FOR INFILTRATION - MEDIUM CONSTRUCTION 72 806 108 ALLOWANCE FOR LATENT HEAT 72 0 224 ALLOWANCE FOR BATHROOM COMFORT 72 291 0 FOR WARM AIR HEATING SYSTEM OR AIR CONDITIONING: REQUIRES : 1 BRANCH DUCT (5 IN ROUND) (5 IN OVAL) OR (3-1/4 X 8 WALL STACK) REQUIRES : 1 #661 6 X 4 SIDEWALL REGISTER OR 1 #411 2-1/4 X 10 FLOOR DIFFUSER OR 1 #16 6 IN ROUND CEILING DIFFUSER OR 1 #24 6 X 6 SQUARE DIFFUSER REQUIRES : 1 #650 10 X 6 RETURN AIR GRILL OR 1 # 659 20 X 14 FILTER GRILL FOR HOT WATER HEATING SYSTEM WITH BASEBOARD 560 BTU AT 180 DEGREES : REQUIRED HYDRONIC BASEBOARD FOR THIS ROOM IS 4 FEET REQUIRED END CAPS ESTIMATED FOR THIS ROOM IS 2 TOTAL TOTAL REQUIRED CFM AND TOTAL BTU HEAT LOSS/GAIN CFM LOSS GAIN CFM AT RECOMMENDED MAXIMUM VELOCITY OF 600 FPM 33 1748 971 BATH MASTER - LEVEL TWO, EAST AREA LOSS GAIN 2 WINDOWS 24 X 36 (IN) , DOUBLE GLASS, NO SHADE IN OR OUT 12 487 852 CEILINGS UNDER VENTILATED ATTIC, R30 INSULATION 90 206 144 FLOOR OVER CONDITIONED SPACE - NO LOSS OR GAIN 0 0 0 EXPOSED WALL 10 X 8 (FT) , FRAME OR VENEER, R19 INSULATION 68 285 115 ALLOWANCE FOR INFILTRATION - MEDIUM CONSTRUCTION 90 1007 135 ALLOWANCE FOR LATENT HEAT 90 0 373 ALLOWANCE FOR BATHROOM COMFORT 90 397 0 FOR WARM AIR HEATING SYSTEM OR AIR CONDITIONING: REQUIRES: 1 BRANCH DUCT (5 IN ROUND) (5 IN OVAL) OR (3-1/4 X 8 WALL STACK) REQUIRES : 1 #661 10 X 4 SIDEWALL REGISTER OR 1 #411 2-1/4 X14 FLOOR DIFFUSER OR 1 #16 6 IN ROUND CEILING DIFFUSER OR 1 #24 6 X 6 SQUARE DIFFUSER REQUIRES : 1 #650 10 X 6 RETURN AIR GRILL OR 1 # 659 20 X 14 FILTER GRILL FOR HOT WATER HEATING SYSTEM WITH BASEBOARD 560 BTU AT 180 DEGREES : REQUIRED HYDRONIC BASEBOARD FOR THIS ROOM IS 5 FEET REQUIRED END CAPS ESTIMATED FOR THIS ROOM IS 2 TOTAL TOTAL REQUIRED CFM AND TOTAL BTU HEAT LOSS/GAIN CFM AT RECOMMENDED MAXIMUM VELOCITY OF 600 FPM CFM LOSS 55 2382 1619 1619 MASTER SUITE - LEVEL TWO, SOUTH & WEST AREA LOSS GAIN 1 WINDOW 36 X 60 (IN) , DOUBLE GLASS, NO SHADE IN OR OUT 15 609 525 CEILINGS UNDER VENTILATED ATTIC, R30 INSULATION 252 579 403 FLOOR OVER CONDITIONED SPACE - NO LOSS OR GAIN 0 0 EXPOSED WALL 18 X 8 (FT) , FRAME OR VENEER, R19 INSULATION 129 541 219 2 WINDOWS 36 X 60 (IN) , DOUBLE GLASS, NO SHADE IN OR OUT 30 1218 2130 EXPOSED WALL 14 X 8 (FT) , FRAME OR VENEER, R19 INSULATION 82 344 139 ALLOWANCE FOR INFILTRATION - MEDIUM CONSTRUCTION 252 2822 378 ALLOWANCE FOR LATENT HEAT 252 0 1138 FOR WARM AIR HEATING SYSTEM OR AIR CONDITIONING: REQUIRES : 2 BRANCH DUCT (6 IN ROUND) (6 IN OVAL) OR (3-1/4 X 8 WALL STACK) REQUIRES: 2 #661 12 X 4 SIDEWALL REGISTER OR 2 #411 4 X 10 FLOOR DIFFUSER OR 2 #16 6 IN ROUND CEILING DIFFUSER OR 2 #24 6 X 6 SQUARE DIFFUSER REQUIRES : 1 #650 10 X 6 RETURN AIR GRILL OR 1 # 659 20 X 14 FILTER GRILL FOR HOT WATER HEATING SYSTEM WITH BASEBOARD 560 BTU AT 180 DEGREES : REQUIRED HYDRONIC BASEBOARD FOR THIS ROOM IS 11 FEET REQUIRED END CAPS ESTIMATED FOR THIS ROOM IS 2 TOTAL TOTAL REQUIRED CFM AND TOTAL BTU HEAT LOSS/GAIN CFM LOSS GAIN CFM AT RECOMMENDED MAXIMUM VELOCITY OF 600 FPM 167 6113 4932 LIBRARY - LEVEL TWO, WEST AREA LOSS GAIN 2 WINDOWS 36 X 60 (IN) , DOUBLE GLASS, NO SHADE IN OR OUT 30 1218 2130 FLOOR OVER CONDITIONED SPACE - NO LOSS OR GAIN 0 0 0 CEILINGS UNDER VENTILATED ATTIC, R30 INSULATION 140 321 224 EXPOSED WALL 10 X 8 (FT) , FRAME OR VENEER, R19 INSULATION 50 209 85 ALLOWANCE FOR INFILTRATION - MEDIUM CONSTRUCTION 140 1567 210 ALLOWANCE FOR LATENT HEAT 140 0 794 FOR WARM AIR HEATING SYSTEM OR AIR CONDITIONING: REQUIRES : 2 BRANCH DUCT (5 IN ROUND) (5 IN OVAL) OR (3-1/4 X 8 WALL STACK) REQUIRES : 2 #661 10 X 4 SIDEWALL REGISTER OR 2 #411 2-1/4 X14 FLOOR DIFFUSER OR 2 #16 6 IN ROUND CEILING DIFFUSER OR 2 #24 6 X 6 SQUARE DIFFUSER REQUIRES : 1 #650 10 X 6 RETURN AIR GRILL OR 1 # 659 20 X 14 FILTER GRILL FOR HOT WATER HEATING SYSTEM WITH BASEBOARD 560 BTU AT 180 DEGREES : REQUIRED HYDRONIC BASEBOARD FOR THIS ROOM IS 6 FEET REQUIRED END CAPS ESTIMATED FOR THIS ROOM IS 2 TOTAL TOTAL REQUIRED CFM AND TOTAL BTU HEAT LOSS/GAIN CFM LOSS GAIN CFM AT RECOMMENDED MAXIMUM VELOCITY OF 600 FPM 117 3315 3443 BED ROOM # 3 - LEVEL TWO, WEST & NORTH AREA LOSS GAIN 2 WINDOWS 36 X 60 (IN) , DOUBLE GLASS, NO SHADE IN OR OUT 30 1218 2130 CEILINGS UNDER VENTILATED ATTIC, R30 INSULATION 196 450 313 FLOOR OVER CONDITIONED SPACE - NO LOSS OR GAIN 0 0 0 EXPOSED WALL 14 X 8 (FT) , FRAME OR VENEER, R19 INSULATION 82 344 139 EXPOSED WALL 14 X 8 (FT) , FRAME OR VENEER, R19 INSULATION 112 470 190 ALLOWANCE FOR INFILTRATION - MEDIUM CONSTRUCTION 196 2195 294 ALLOWANCE FOR LATENT HEAT 196 0 919 FOR WARM AIR HEATING SYSTEM OR AIR CONDITIONING: REQUIRES : 2 BRANCH DUCT (5 IN ROUND) (5 IN OVAL) OR (3-1/4 X 8 WALL STACK) REQUIRES: 2 #661 10 X 4 SIDEWALL REGISTER OR 2 #411 2-1/4 X14 FLOOR DIFFUSER OR 2 #16 6 IN ROUND CEILING DIFFUSER OR 2 #24 6 X 6 SQUARE DIFFUSER REQUIRES: 1 #650 10 X 6 RETURN AIR GRILL OR 1 # 659 20 X 14 FILTER GRILL FOR HOT WATER HEATING SYSTEM WITH BASEBOARD 560 BTU AT 180 DEGREES : REQUIRED HYDRONIC BASEBOARD FOR THIS ROOM IS 9 FEET REQUIRED END CAPS ESTIMATED FOR THIS ROOM IS 2 TOTAL TOTAL REQUIRED CFM AND TOTAL BTU HEAT LOSS/GAIN CFM LOSS GAIN CFM AT RECOMMENDED MAXIMUM VELOCITY OF 600 FPM 135 4677 3985 WHOLE BUILDING ALLOWANCES LOSS GAIN LOSS/GAIN FOR OCCUPANTS 0 0 1125 SYSTEM DESIGN FOR WARM AIR HEATING SYSTEM OR AIR CONDITIONING: REQUIRED SUPPLY TRUNK DUCT IS 30 X 8 REDUCED 2 INCHES EVERY 30 FEET REQUIRED RETURN TRUNK DUCT IS 34 X 8 REDUCED 2 INCHES EVERY 30 FEET FOR HUMIDIFICATION SYSTEM TO MAINTAIN 35s RH AT 70 DEGREES : REQUIRED HUMIDIFIER TO HAVE AN EVAPORATIVE CAPACITY OF 13 GALLONS PER DAY FOR HOT WATER HEATING SYSTEM WITH BASEBOARD 560 BTU AT 180 DEGREES: REQUIRED HYDRONIC BASEBOARD FOR WHOLE HOUSE IS 85 FEET REQUIRED END CAPS ESTIMATED FOR WHOLE HOUSE IS 16 TOTAL REQUIRES ONE # VR 15 F VENT-RITE TYPE EXPANSION TANK GRAND TOTAL REQUIRED CFM AND TOTAL BTU HEAT LOSS/GAIN CFM LOSS GAIN CFM AT RECOMMENDED MAXIMUM TRUNK VELOCITY OF 1000 FPM 1231 47264 36210 10/24/2000 15:15 FAX 860 887 7898 UXCAS HEALTH DISTRICT (,21002 loo Piz u c Uncas Health District 372 W. Main Street- 2n''Floor Norwich, CT 06360-5450 Telephone No. (860) 823-1189 FAX No. (860) 887-7898 E-Mail: office@uncashd.org Internet: http://www.uncashd.org Serving the People ofNorwich and Montville Pas,�ut# 1534 PERMIT TO DISCHARGE TO A SUBSURFACE SEWAGE DISPOSAL SYSTEM Permission is hereby granted to to discharge sewage to the subsurface sewage disposal system located at 100 Pruett Place in the Town of Montville. Issuance date: October 23, 2000 Issued by: 6- Arthur Cohen Director of Health Provisions: 1) Discharge volume is not to exceed 125 gallons per day per bedroom from a 4-bedroom house. 2) The septic tank and outlet filter shall be inspected regularly and cleaned at least every two to five years. Special requirements or restrictions: The iron level of 3.7 rng/L is above the recommended level of 0.3 mg/L, and the manganese level of 0A4 mg/L is above the recommended level of 0.05 mg/L. These are not health hazards,but may cause staining of plumbing fixtures and laundry. If desired, treatment to remove iron and manganese is available. Code exceptions: None This permit shall not be construed as permission to create or maintain any sewage nuisance. If such a condition is found to exist, this permit may be revoked, suspended or modified.. The permit holder shall be required to make whatever repairs, alterations, extensions or changes in use as are deemed necessary by the Uncas Health District to abate the condition.