HomeMy WebLinkAboutLP Line for Gas Logs 1995 rf TOWN OF MONTVILLE I<
I I
Building Department Pd/ i
848-7166
APPROVED BUILDING PERMIT OR TRADES PERMIT
For 180 Days
Permit No: 11970 Approval Date: 01-24-95 Expiration Date: 06-24-95
Estimated Cost: 600 Fees: 10 PRF: C .O:
Owner : Herb Plotnik Address: 72 Pollys Ln Tel : 848-7369
Job Location: same Code: 06
Contractor : SLS Address: POB 424 Waterford Tel : 447-8709
Stick Built: x Modular Home: Manufactured Home: Commercial :
Addition: Garage: Car Port: Shed: Remodeling: Roofing:
Siding: Fireplace: Chimney: Windows: Pool : Demolition:
Plumbing: Heating: Electrical : Air Conditioning: Gas:
Patio: Porch: Deck: Retaining Wall : New: Repair/Replacement:
Type of material used/discription: install gas line for gas log
Size: Type of Heat: Fireplace:
No.of Stories: No . Rooms: Breezeway:
No . Baths: Garage: Use:
I hereby certify that the proposed work will conform to the Basic
Building Code and all other Codes as adopted by the State of Connecticut , and
the Town of Montville .
Applicant 's Signature: ✓ A4z7. t Date: 01-
If
1 If signed by Contractor , type of license/registration & No: 3O3 3q
Building Official 's Signature: � Date: 01- ')- 1-1:-
Date
1- '21-t-Date of Health Dept . Approval : N/�
Date of Zoning Approval : x /�
THIS IS TO INFORM YOU THAT UNDER THE CONNECTICUT AMENDMENT OF THE
BUILDING CODE , SECTION 119 .3 A CERTIFICATE OF OCCUPANCY IS REQUIRED PRIOR TO
ANY USE OF THE STRUCTURE .
A MINIMUM OF 24 HOUR NOTICE TO THE BUILDING DEPARTMENT IS REQUIRED FOR
INSPECTIONS .
v (C).
TOWN OF MONTVILLE ' (90
Building Department '
Application for a Permit
Owner: HE-RQ 1 C�t�iK Address: Palk/4 C, c` Tel : y� e,
� t/3
Job Location:
Contractor : SC �I��-( , Address: P•°• Rm)( yZY (.4jitp Tel : `/) f909
Stick Built: _112 , Modular Home: Manufactured Home:
commercial :
Addition: Garage: Car Port: Shed:
Remodeling: Roofing:
Siding: Fireplace: Chimney: Windows: Pool : Demolition:
Plumbing: Heating: Electrical :
Air Conditioning: Gas:
Patio: — Porch: Deck: — Retaining Wall : New:
— — Repair/Replacement:
Type of Material to be used/job description: ,.�5 ��( 0 �
�' S SNC 4-12
tis L�
Size: Type of Heat:
Fireplace:
No.of Stories: No . Rooms:
Breezeway:
No . Baths: Garage:
Use:
w
DESA INTERNATIONAL
UNVENTED -
VENT FR
EE
PROPANELOG11
GAS
(Also Designed Certified as Vented Decorative Heater)
OWNER'S OPERATION AND INSTALLATION MANUAL
- i4 ,,
)1,0
44.,,,,,,,,si ..:
• ..... _\,,, .,.... , .
.4.
, ,„„,o . 7 .
..,
. .
�
�• O N
..,
18", 24", and 30" Log '�`( ,,,,f-,4,
•
Sets
Thermostat and Manually-Controlled reftri t +!
y Controlled Models
WARNING: If the information in this manual WARNING:Improper installation,
is not followed exactly, a fire or explosion adjustment, alteration, service, or
may result causing property damage, per-
sonal injury, or loss of life. I maintenance can cause injury or
— Do not store or use gasoline or other property damage. Refer to this
flammable vapors and liquids in the manual for correct installation and
vicinity of this or any other appliance. operational procedures.Forassis-
-' WHAT TO DO IF YOU SMELL GAS tance or additional information
consult a qualified installer, ser-
• Do not try to light any appliance. vice agency, or the gas supplier.
• Do not touch any electrical switch; do
not use any phone in your building.
• Immediately call your gas supplierfrom WARNING:This gas log set is for 1
a neighbor's phone. Follow the gas installation in a masonry solid fuel
•
supplier's instructions. burning fireplace or a U.L. listed
• If you cannot reach your gas supplier, manufactured solid fuel burning
call the fire department. fireplace only.
— Installation and service must be per-
formed
by a qualified installer, service
agency, or the gas supplier.
Save this manual for future reference.
7 s .
. .
•
INSTALLING
3. Pressurize supply piping system by either using compressed air or
Iopening propane supply tank valve.
Continued 4. Check all joints of gas supply piping system. Apply mixture of liquid soap and water to
gas joints.Bubbles forming show a leak.
5. Correct all leaks at once.
6. Re-connect heater and manual shutoff valve to gas supply.Check re-connected fittings
for leaks.
Test Pressures Equal To or Less Than 1/2 PSIG
1. Close manual shutoff valve(see Figure 15).
2. Pressurize supply piping system by either using compressed air or opening propane
il supply tank valve.
3. Check all joints from propane supply tank to manual shutoff valve(see Figure 16).
Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak.
4 4. Correct all leaks at once.
Pressure Testing Heater Gas Connections
1 1. Open manual shutoff valve(see Figure 15).
2. Open propane supply tank valve.
3. Make sure control knob of heater is in the OFF position.
4. Check all joints from manual shutoff valve to thermostat gas valve(thermostat-con-
4! trolled models)or control valve(manually-controlled models)(see Figure 16). Apply
mixture of liquid soap and water to gas joints.Bubbles forming show a leak.
5. Correct all leaks at once.
6. Light heater(see Operating Heater,pages 20 through 23).Check all other internal
joints for leaks.
1 7. Turn off heater(see To Turn Off Gas to Appliance,page 21 [thermostat-
controlled models]or page 23 [manually-controlled models]).
11
Open
s
Manual 1 :._
Shutoff \
Valve
Closed
I.'
Figure 15-Manual Shutoff Valve
Manual Thermostat Gas Valve or
j. Shutoff Control Valve Location
j Valve
Propane ,- j
Supply Tanky,75)
1
i(c3)t / --
iiiiiiiiMigii
o� ed:„::.v.
Figure
Figure 16-Checking Gas Joints
a
I
,
101300
•
OPERATING 5. Press in control knob and turn counterclockwise
ic \ to the PILOT position.
Keep control knob pressed in for five(5)seconds (see Figure 22).
HEATERNote:You may be running this heater for the first time after hooking up to gas
supply.If so,the control knob may need to be pressed in for 30 seconds.This will
Manually-Controlled
Models allow air to bleed from the gas system.
• If control knob does not pop out when released,contact a qualified service
Continued person or gas supplier for repairs.
6. With control knob pressed in,press and release ignitor button.This will light pilot.
The pilot is attached to the front burner.If needed,keep pressing ignitor button
until pilot lights.
Note:If pilot does not light,contact a qualified service person or gas supplier for
repairs.Until repairs are made,light pilot with match.To light pilot with match,
see Manual Lighting Procedure,below.
7. Keep control knob pressed in for 30 seconds after lighting pilot.After 30 seconds,
release control knob.
Note:If pilot goes out,repeat steps 3 through 7. Ignitor Electrode
Thermocouple
Pilot Burner
4kilo 414411
•
11 0
Figure 23-Pilot
8. Turn control knob counterclockwise /C---\ to the LOW position.The front
burner should light.Set control knob to either HIGH,MEDIUM,or LOW.To turn
control knob from LOW to a higher setting,press in the control knob and turn
counterclockwise ic"—\ .On LOW and MEDIUM positions,only front burner
operates.On HIGH position,front and rear burner operates.
A WARNING
HIGH, MEDIUM,and LOW are locked positions. You must press in
control knob before turning it from these positions. Do not operate
heater between locked positions or sooting could occur.
A CAUTION
Do not try to adjust heating levels by using the manual shutoff valve.
TO TURN OFF GAS TO APPLIANCE
Shutting Oft Heater
I. Press in and turn control knob clockwise to the PILOT position.
2. Press in control knob and turn clockwise to the OFF position.
Shutting Off Burners Only(pilot stays lit)
I. Press in and turn control knob clockwise /\to the PILOT position.
MANUAL LIGHTING PROCEDURE
1. Follow steps 1 through 5 under Lighting Instructions,page 22.
2. Depress control knob and light pilot with match.
1111
3. Keep control knob pressed in for 30 seconds after lighting pilot. After 30
seconds,release control knob.Now follow step 8,above.