Loading...
HomeMy WebLinkAbout10x10 Deck and Door Replacement 2009 Field Inspection Notice Town of Montville Building Department Address: 80 Moxley Road Job Description: Rear Door& 10x10 Deck Permit Number(s) B2009-0556 Permit Date: December 14,2009 Not Approved Approval INSPECTION Date: Deficiencies Special Date Conditions Two piers 12/14/09 DJ Framing 12/15/09 DJ • • Final inspection for • certificate of 12/15/09 DJ occupancy NOTICE: Before a certificate of occupancy can be issued, a C/O signoff sheet must be completed and returned to the building department. Signoff sheets are available in the building department. Rev.Date: 1/18/06 page s of t TOWN OF MONTVILLE Building Department 310 NORWICH-NEW LONDON TURNPIKE UNCASVILLE, CT 06382-2599 TEL. (860) 848-3030 X382 FAX. (860) 848-7231 BUILDING PERMIT Permit Number: B2009-0556 Date: 14-Dec-09 Map/Lot: 017/003-000 Owner ID: 4464000 Project Location: 80 MOXLEY ROAD Unit: Job Description: Replace Large Window with Door&10x10 Rear Deck Owner Name: Michael and Anne Tortora Tenant Name: N/A Careof: 80 Moxley Hill Rd Uncasville CT 06382- Telephone: Contractor Name: Edward D. Daigle Telephone: (860)961-9454 DBA: Ed Daigle Construction Lic/Reg Type: HIC Lic/Reg No: 500720 P.O. Box 187 Exp Date: 30-Nov-10 Uncasville CT 06382- Construction Value Permit Fees Construction Information Building Value: $4,389.00 Building Fee: $40.00 Use Group: IRC Plumbing Value: $0.00 Plumbing Fee: $0.00 Code: 2005 State Building Code Mechanical Value: $0.00 Mechanical Fee: $0.00 Electrical Value: $0.00 Electrical Fee: $0.00 Construction Type: IRC Total Value: $4,389.00 Penalty Fee: $0.00 Permit Code: R10 C of 0 Fee: $10.00 Comments: Plan Review Fee: $4.00 State Ed Fee: $0.97 Total Fee Paid: $54.97 It shall be the owners repsonsibility to schedule the following inspections a minimum of 2 business days in advance: Field set of approved construction documents shall be available onsite during all inspections. BUILDING PERMIT INSPECTIONS PLUMBING,MECHANICAL, ELECTRICAL PERMIT INSPECTIONS El Footing- Prior to pouring concrete ❑ R Plumbing and leak test VJ Deck Piers ❑ R Electrical ❑ Backfill - Footing drains and waterproofing ❑ Elec Trench -with conduit installed ❑ Concrete Slab- Prior to pouring concrete ❑ Pool Bonding ❑ Anchor Bolts-with sill plate and prior to floor framing ❑ Electrical Service CRS No: 0 ❑ Framing ❑ R HVAC ❑ Masonry Fireplace Throat or Chimney Thimble ❑ Gas Piping and leak test ❑ Fireblocking Draftstopping INSPECTION REQUIRED UPON COMPLETION ❑ Insulation cate • •pproval Ce i . e of Occupancy Building Official's A.'royal: Town of Montville Building Department 310 Norwich-New London Tpke. Tel. 860-848-3030, Ext 382 Uncasville, CT 06382 Fax. 860-848-7231 RESIDENTIAL PERMIT APPLICATION FORM Permit No.: 6 —D Type of Work Occupancy Type Permit Type 0 New Construction ❑Single Family ❑Building 5;cl:dip ❑Two-Family ❑ Plumbing n 0 Townhouse ❑Mechanical 0 Accessory Structure 0 Electrical CRS#: Property Address: jam' 14C) l.c (Number) (Street) I (Unit) Job Description: 22t.�t V 'z. t/t ►^f�e (,t),, ,_rv„ 7-‘ Od Owner: / ' h ore tT2i Pie)Address: d U /e✓ 2 (A City:OA)C 14-S J% 1/f State:(? 1 Zip Code063 di— Telephone(VO ) Applicant: / /w14 v1 :) 7) /9.IV��✓ DBA: �'l I '6 L( Address: 1�g /( 1 5 / {. / City: U!\/C10 c)% 1 `L State: C/ Zip Code° (:— Telephone(f Z±/�f/( -9V4I Contractors-Complete the Following: 7 } License Typed) '2,C2 �Z r!v License No.:O� "C & Expiration Date: /� S i C) f I hereby certify that the proposed work will conform to the State Building Code and all other codes as adopted by the State of Connecticut and the Town of Montville and further attest that the proposed work is authorized by the owner in fee and that/am authorized to make application for a permit for such work as described above. 0 By checking this box,I will follow the requirements of the 2005 NEC as the alternative compliance per section E3301.2.1 of the Residential Code, instead of the electrical requirements in chapters 33 through 42 of the Res Resydential Code. Owner/Agent Signature: Date: /( t? �l Construction Value Permit Fees Building Value: Building Fee: Plumbing Value: Plumbing Fee: Mechanical Value: Mechanical Fee: Electrical Value: Electrical Fee: Total Value: Penalty Fee: C of 0 Fee: Plan Review Fee: State Ed Fee: Total Fee: RrviceEAugust 23,2007 Town of Montville Building Department File Receipt Date: 24-Nov-09 Receipt No: 5094 Received From: Ed Daigle Job Address: 80 Moxley Road Fees Collected State Educational Training Fee Cash: $54.97 Cash: $0.97 Check: $0.00 Check: $0.00 Check No: 0 Short/Over: $0.00 Construction Value: $4,389.00 Demolition Value: $0.00 Received By Carmen Kneeland OaA�A� 1/17) . �� (xi/id AAAAAess: 80 Moxley Road ITEM QTY SIUNIT TOTAL Building Plumbing Mechanical Electrical BUILDING AREA New Construction SF $ 113.03 $ - $ - Basement,Finished SF $ 22.96 $ - $ - Basement,Unfinished SF $ 12.40 $ - $ - Crawl Sapce SF $ 9.30 $ - Interior Renovations SF $ 35.09 $ - $ - $ - MANUFACTURED HOMES Ground Anchors SF $ 6.45 $ - $ - $ - Basement SF $ 12.41 $ - $ - $ - _ Crawl Space SF $ 9.31 $ - $ - $ - AMENITIES Kitchen 0 EA $ - $ - $ - Full Bathroom 0 EA $ - $ - Half-Bathroom 0 EA $ - $ - GARAGE Attached 0 SF $ 54.35 $ - $ - Detached SF $ 69.53 $ - $ - Under - SF $ 10.03 $ - $ - Carport - SF $ 19.89 $ - MECHANICAL Warm-Air Y/N $ - Hot Water n- Y/N $ - Electric n- Y/N $ Air Conditioning n- YIN $ - ELECTRICAL SERVICE Upgrade Amps $ - Overhead,new -Amps $ - Underground,new 0 Amps $ Subpanel EA $ 599.50 $ - Gen Set - EA $ 3,850.00 $ - SOLID FUEL BURNING APPLIANCES Prefab Metal Fireplace EA $ 6,497.70 $ - Masonry w/l fireplace - EA $ 7,096.65 $ - Masonry wl2fireplaces - EA $ 11,095.70 $ - Wood Stove,free standing EA $ 2,692 25 $ - Wood stove insert EA $ 1,859.77 $ - DECKS,PORCHES,SUNROOMS Deck 100 SF $ 37.87 $ 3,787.00 Porch - SF $ 149.38 $ - Sunroom SF $ 176.90 $ - $ - POOLS&HOT TUBS Hot Tub EA $ 8,016.25 $ - $ - Inground Pool - EA $ 21,373.44 $ - $ - Above Ground Round - EA $ 5,099.46 $ - $ - Above Ground Oval EA $ 6,019.75 $ - $ - Pool Heater EA $ 8,984.25 $ - Inflatable Type Pool - EA $ 1,550.00 $ - SHEDS w/o electrical SF $ 20.35 $ - w/electrical - SF $ 20.35 $ - $ - RENOVATIONS Roofing,Overlay SF $ 3.00 $ - Roofing,Strip&reroof - SF $ 4.00 $ - Roof Sheathing - SF $ 1.31 $ - Siding - SF $ 5.50 $ - Windows EA $ 500.00 $ - Skylights - EA $ 1,051.10 $ - Doors,Exterior 1 EA $ 601.50 $ 601.50 Oil Tank,275 Gallon - EA $ - Oil Tank,550 Gallon - EA $ - MISCELLANEOUS CALCULATIONS TOTALS $ 4,388.50 $ - S - $ - PERMIT FEE CALCULATIONS Construction Value Fee Building $ 4,389.00 $ 40.00 Plumbing y $ - $ _ Mechanical y $ - $ _ Electrical y $ - $ - Working before Permit Issuance $ - Certificate of Occupancy Fee $ 10.00 Plan Review Fee $ 4.00 State Education Fee $ 0.97 TOTALS $ 4,389.00 $ 54.97 Figures are based on the 2006 RS Means Residential Cost Data - STATE OF CONNECTICUT DEPARTMENT OF CONSUMER PROTECTION • HOME IMPROVeSENT CONTRACTOR • WA RD D DAIGLE 43 RD144 EP,riAttit4 CQ?S: LIC./REG NO E IV;p44, ; EXPIRES 4-M.0500729 f4- .--ii/30/2009 • SDQ o&C • • • • Town of Montville Building Department • 310 Norwich-New London Tpke. Tel. 860-848-3030, Ext 382 Uncasville, CT 06382 Fax. 860-848-7231 CONSTRUCTION PERMIT APPROVAL Applicant is responsible for obtaining all of the required approvals. No permit will be issued until all the required signatures are obtained. Property Address 7 Job Description - Required for all permits ® - At least one required for all permits ❑ -Required as indicated below Required Department Permit Issuance Approval Approval ^ ® Tax Collector �I C�Signature/da(2_ Comments: 1 ' ® Planning & Zoning � �� /(/.z VG) c, Signature/date • 6 Comments: ( L I Fire Marshal /17 ( 12 l0 (yr Signature/datea) VP Comments: v✓ Health Department j � kitW12-11< Required for properties with septic systems-Not re.uired for Plu ....!..�t3a ' al Mechanical Rooi(n. Sidin. indo s&Doors Comments: IO 1� Srot►f e s t— ® WPCA, Administrative Required for properties on sewer Signature/date Comments: ❑ WPCA, Operations When Required by WPCA Signature/date Comments: ❑ Department of Public Works Required when project includes driveway work or certain drainage requirements Signature/date Comments: ❑ State Dept. of Transportation Required for Structures over 100,000 sq. ft. or with more than 200parking spaces-Official copy of STC Certificate of Operation required—per CGS 14-311 Signature/date Building Department Review Complete Signature/date jvisedJ"ovemfer5,2008 Town of Montville Buildinq Department • 310 Norwich-New London Tpke. Tel. 860-848-3030, Ext 382 Uncasville, CT 06382 Fax. 860-848-7231 CONSTRUCTION PERMIT APPROVAL Applicant is responsible for obtaining all of the required approvals. No permit will be issued until all the required signatures are obtained. ZO Proplerty Address Es ✓ViCe Job Description - Required for all permits ® - At least one required for all permits ❑ - Required as indicated below Required Department Permit Issuance Approval Approval Tax Collector �� �-- c�., s_ i_' ��I / a t Signature/date Comments: Planning & Zoning f U ,�,.—► Signature/date Comments: Fire Marsha I ^(� ( , ' nI Signature/date Comments:c �Iv� L� �"r�L�� ��-- ® Health Department Required for properties with septic systems—Not required for Plumbing, Electrical, Mechanical,Roofing,Siding,Windows&Doors Signature/date Comments: ►.4 WPCA, Administrative Required for properties on sewer Signature/date Comments: n WPCA, Operations When Required by WPCA Signature/date Comments: ❑ Department of Public Works Required when project includes driveway work or certain drainage requirements Signature/date Comments: ❑ State Dept. of Transportation Required for Structures over 100,000 sq. ft. or with more than 200 parking spaces- Official copy of STC Certificate of Operation required—per CGS 14-311 Signature/date Building Department Review Complete Signature/date 4svisedJr",vcmfrcr5,2008 e..r ca.-se'' I k 1 i.. [u9, cr) 0,. 1 t 1111.. 4 ,, f � JI Ca M ! mocoo J o = oo > c' °' ' N. i Vma °- 0 N,,_h i ' AZ 1 0 3..0 L. r- •-•.,., '41/4r, i 4r, ; — i 0 ? S CO O Q. N. 1 _. oc.� a) o0 - i " i HQ 'o Ca.> Ua i r 0. 3 *xi,. }} r I 41+ j f i t `• i j t t i 1 '. - t i . i. ii `d 1A t�- ., t ( 1.r s_ ;. _ -_.__ _.__ _._ _ - r ''" . 1 1 . i s LU I W cq Z 0 .......„. a, . .:. — i co 1 -)r 1 i-4 0.- i i I i 1 , . 4t. i L.... t---,, J I t. -,...., TC' I i c--> .c. ...< St •Z ,..., N1 kl \ .3 ......, .r.1 \ i qr L. • I ca ...... `. v) -.a\ \ Q[ ,... \ 1 Nr,..0., ,.. . .... te c..„,, 4,..). L ,...) -4, ,...,3 „...„ ... . t„ \ ..,„ i 1 4...., ... 4,............, „, ,N.. N. ...t -4.4. .., ,..- i \ ,..„.... .,..... ___ . _ ._ 1_ 4 --,•/* x....! 171. I... 1 1....‘-' '.., ._) • 'i 6* • • •. i t.,,.., 4-- C4, 4r: .,•;,,..., 2,4 ...._4 , ....,, ..'' . .„.t. 1 . ; ....., , 1 .1'.C) ....,.. 0 .I , i rl, I..............,....,--.—..,--- ! Mi'l" .... --, • '.I.,-.,..2g ' 'P''-- I I LL1 ) . l, 111,1 C . . , ....„,„ , i M ..... , : . • \ , - ----1 F ! . 1. 1 k\ . i .......!.,:s.:. 1 . . . . i ' . ,c, i • s'..;z: -.... i -•---..-.. -.--E.,,nn.,,,,t,.--..---twir...;:-‘7,t.,..........---,--....--.—.....-------,--....—..----- . , , --, i • e.. I t . c , I : i t : t 7t- 1 i 1 ! ' ! . 1 4 ...... A .r . 1.3 • . 1 / .......,......—..................,,......-, ,...... ..---.......--.............. I ... „ I i ... ..—. 4.73 I r ) . i .1/4, . , r" ......r .... , . i . k...., ,........ t ..7 '-.. C..„_. i i .''',. \''. ..........,...,1_,. .. _...,.......„........... I----...' "'•-... '... —... ...--.......-... C...) "N.,...., ,...0 ,_... lr. et.. (:),..... • 1111 • . Town of Montville Building Department Residential Accessory Structure Plan Review Form Date: ;2//�/e) `i Job Address: g° /V l O&/-tor y Rd -// Job Description: g /f C t II.e_in'''.P L.. i 0cl//r,... t'-• 1-I4 C C err.'^ a m d CoHsb-t-! -t ,L /(-x A ice. <<-i Your permit application is being rejected for the items checked off or commented on. The required information must submitted for review(two sets are required) (C.G.S.29-252a.) This list is offered as a guideline only. It is not meant to be all-inclusive for every permit application,nor is it meant to take the place of the State Building Code. SUPPORTING DOCUMENTATION SITE PLAN Permit application not completed Plans required Permit fee due S Plans do not match the building plans Permit fee to be calculated Finish floor elevation not indicated Worker's comp.affidavit or worker's comp.certificate to be submitted Distance from the property line(s)to the structure not identified Copy of contractor's registration or license required Structure dimensions not provided Construction permit sign-off sheet required with appropriate approvals,it shall Existing and proposed contours are not provided or insufficient be the applicant's responsibility to obtain the required signatures Footing drain discharge not identified Affidavit required from the holder of the registration or license authorizing you Utilities not provided(electrical,phone,cable,sewer,water,gas) to apply for a permit with their information Delineation of flood hazard areas and design flood elevation is required per Provide supporting documentation to show compliance with the 2003 IECC section R106.1.3 (www.enerrycodes.gov)OR Private sewage disposal system to be identified along with all technical and soil • One-and Two-Family Dwellings with<15%glazing area to conform to the data as per section R106.2.I requirements of section N1102.1 Grading is to slope away from the building,provide more detailed information • Townhouses with<25%glazing area to conform to the requirements of Plan submitted is not the same plan that has been approved by the Zoning section N1102.1 Department and/or Health Department Two sets of construction documents required, this includes all engineering Retaining wall—construction documents required data,calculations and all other documentation(R106.1) Retaining wall documents required to be stamped and signed by a Connecticut Documents are copyright protected,provide original plans or a letter from the Registered Professional Engineer designer authorizing the duplication of the plans Field set of the approved construction documents are required to be picked up FOUNDATION from our office and must be available on site during all inspections No plans submitted or insufficient information Construction documents shall be of sufficient clarity to indicate the location, Dimensions required nature and extent of the work proposed as per section R106.1.1 Wall thickness not identified Construction documents do not match the orientation of the structure on the Footing size not identified site plan Frost protection not identified or is insufficient Column type,size,spacing not identified or insufficient WIND LIMITATIONS Waterproofing details not provided or insufficient Submit supporting data to show conformance with the wind limitations (3 Pier type,size and anchor details not provided or insufficient second gust @ 110 mph) Engineered foundation plan required Design publication needs to be identified(WFCM,chapter 3;WFCM,chapter Crawl space ventilation,location,type and size not provided or insufficient 2;ASCE 7-2002;SSTD10-99) Crawl space access,location and size not provided or insufficient Documents required to be stamped and signed by a CT registered Professional Engineer ' WINDOWS&DOORS DocumentsDoffients must be designed to either kp' lc Door sizes not identified • Wood Frame Construction Manual 2001 edition '2„,)('' / Window size&type not identified • ASCE 7—2002 edition A / Window header size not identified or insufficient • SSTD 10—1999 edition cC) Door header size not identified or insufficient Documents required to be stamped and signed by a CT registered Professional Engineer if based on ASCE 7-02 or WFCM chapter 2 GARAGE and CARPORTS Shearwalls not identified on the construction documents or are insufficient No plan submitted or insufficient information provided Sheerwaf calculations required Building section required Ridge connection not identified or insufficient Opening protection between the garage and residence is not identified or Roof-to-wall connection not identified or insufficient insufficient per section R309.1 Wall-to-wall connection not identified or insufficient Separation between the garage and the residence is not identified or insufficient Wall-to-sill connection not identified or insufficient per section R309.2 Provide engineering data for the piers to resist gravity,lateral,shear and uplift loads,stamped and signed by a CT licensed design professional ELEVATIONS Hold-clown devices,location and type not identified or insufficient No plans submitted or insufficient information Foundation anchor spacing not identified or insufficient Plans do not match the floor plans Construction documents do not match the engineering data submitted Finish grade not identified or does not match the site plan Cold-formed steel framing shall be designed in accordance with COFS/PM- Building height(s)not identified 2001 edition Dimension height of chimney Roof pitches not identified jvizeiNay 4,2007 Town of Montville Building Department STAIRS Stair not shown SHEDS Riser height not identified or insufficient Structure has an area of more than 400 square feet - frost protection is Tread depth not identified or insufficient required,provide details(8403.1.4.1) Nosing required for closed riser stairs (840Eave height is greater than 10 feet-frost protection is required,provide rt 1a;ts (8403.1.4.1) Riser opening can not allow the passage of a 4"sphere Ground anchors are Winder stair-detailed plans required required provide information and le4ails Spiral stair-detailed plans required POOLS/HOT TUBS Stair width required to be minimum of 36"above the required handrail height Handrail detail not provided or insufficient detail Provide information and derails for barrier Guardrail detail not provided or insufficient detail Gate can not swing out over stairs Headroom height not identified or insufficient Gate required swing away from the pool area 36"len Sidewall support brackets required to be protected by a barrier, provide ding required at the bottom of the stairs information and details 36"landing required at the top of the stairs Gates to self-closing and self-1 Frost protection required,provide details and connections Doors from residence requiredtobye alarmed OR self-closing,self-latching FRAMING on pump receptacle dimension from the pool wall is required-show location en plan Stud size and spacing not provided or insufficient General purpose receptacle required(min 10 ft,max 20 ft from pool)-show Sheathing type not provided or insufficient location on the plan Plans required showing joists,beams and openings Wring type not identified or unclear Bearing partitions not provided or indicated Wiring method not identified or unclear Framing direction not indicated or unclear Burial depth not identified or unclear XBeam size not provided or insufficient Bonding requirements not idriiri d or unclear Joist span,size&spacing not provided Light fixtures-manufacturers installation instructions required Joist's over-spanned Electricalplanfor Beam over-spanned required pool Provide design data for all unaligned wall and floor bearing points FLOOD-RESISTANT CONSTRUCTION(R323) Point loads not identified on beam data Documentation required to be submitted for the connection,anchored to resist Framing less than 18"to grade to be pressure treated or decay resistant flotation,collapse or permanent lateral movement Steel beam- must be stamped and signed by a Cormeticu t Professional Delineation of flood hazard areas,floodway boundaries, and flood zones and Fnsineer the flood design elevation to be identified on the site plan(8106.1.3) LVL's-engineering data required Elevation of the proposed lowest floor,includingb I job-engineering data required flooding eselowesteto infloor,areas of shallow (AO zones), the height of the proposed including Design loads not provided or insufficient basement,above the adjacent highest grade shall be identified(8106.1.3) Electrical systems, equipment and components, and heating, ventilation, air DECKS I PORCHES S conditioning and plumbing appliances, plumbing fixtures, duct systems, and Construction documents requiredother service equipment shall be located at or above the design flood elevation_ Dimensions required Framing direction not indicated ELECTRICAL INFORMATION Beam span size not provided or insufficient Plans required showing panel locations,GFCI,switches,lights and receptacle Joist span,size&spacing not provided locations Joist's aver-spannedPanel location not identified Beam over spanned Receptacle locations not identified or insufficient GFCI receptacle locations not identified or insufficient Ledger-show art•rhmmt and flashing detail Post size or spacing not indicated Lights and switches not identified or insufficient Height of deck above adjacent finished grade not provided Location of time clock not identified Connections not identified or insufficient Plans do not match site plan FUEL GAS INFORMATION LP-Gas tank size and location not identified on the plans Trench detail not provided or insufficient Piping diagram not submitted or insufficient Comments: C Se- c > r/ SPr Cyo . .S i'7o/` S1 Ct'rS 4i1f)t- cLiL.w✓r. Permit application reviewed by. • _ ! Vernon D.Vesey II David , omen Building Official Deputy Building Oficial Rfivirear5Way 4,2007