HomeMy WebLinkAbout14x38 Deck 2009 TOWN OF MONTVILLE Building Department 310 NORWICH-NEW LONDON TURNPIKE UNCASVILLE, CT 06382-2599 TEL. (860) 848-3030 X382 FAX. (860) 848-7231 BUILDING PERMIT Permit Number: B2009-0267 Date: 26-Jun-09 Map/Lot: 039/095-000 Owner ID: 5527000 Project Location: 75 PIRES DRIVE Unit: Job Description: 38x14 Deck Owner Name: Michael and Melissa Clark Tenant Name: N/A Careof: 75 Pires Drive Oakdale CT 06370- Telephone: (860)848-8868 Contractor Name: Lynn Nelson Telephone: (860)848-1182 DBA: Nelson Building and Contruction LLC Lic/Reg Type: HIC Lic/Reg No: 573264 511 Fitch Hill Rd. Exp Date: 30-Nov-09 Uncasville CT 06382- Construction Value Permit Fees Construction Information Building Value: $21,280.00 Building Fee: $176.00 Use Group: IRC Plumbing Value: $0.00 Plumbing Fee: $0.00 Code: 2005 State Building Code Mechanical Value: $0.00 Mechanical Fee: $0.00 Electrical Value: $0.00 Electrical Fee: $0.00 Construction Type: IRC Total Value: $21,280.00 Penalty Fee: $0.00 Permit Code: R10 C of 0 Fee: $10.00 Comments: Plan Review Fee: $17.60 State Ed Fee: $3.83 Total Fee Paid: $207.43 It shall be the owners repsonsibility to schedule the following inspections a minimum of 2 business days in advance: Field set of approved construction documents shall be available onsite during all inspections. BUILDING PERMIT INSPECTIONS PLUMBING, MECHANICAL, ELECTRICAL PERMIT INSPECTIONS • Footing- Prior to pouring concrete ❑ R Plumbing and leak test Deck Piers ❑ R Electrical ❑ Backfill- Footing drains and waterproofing ❑ Elec Trench-with conduit installed ❑ Concrete Slab- Prior to pouring concrete ❑ Pool Bonding ❑ Anchor Bolts-with sill plate and prior to floor framing ❑ Electrical Service CRS No: 0 ❑ Framing ❑ R HVAC ❑ Masonry Fireplace Throat or Chimney Thimble ❑ Gas Piping and leak test ❑ Fireblocking_Draftstopping INSPECTION REQUIRED UPON COMPLETION ❑ Insulation la Certificate of Approval ica - if Occupancy Building Official's Approval: Town of Montville Building Department 310 Norwich-New London Tpke. Tel.860-848-3030, Ext 382 Uncasville, CT 06382 Fax. 860-848-7231 RESIDENTIAL PERMIT APPLICATION FORM Permit No.: 6DX9'OD-197 Type of Work Occupancy Type Permit Type New Construction ❑ Single Family 0 Building 0 Addition 0 Two-Family ❑ Plumbing ❑Alteration ❑Townhouse ❑ Mechanical ❑Accessory Structure 0 Electrical CRS#: Job Address: —15 P,r Q_S (Z (Number) (Street) (Unit) Job Description: 3' / V Owner: Yr l Address: City: O Q C�AcA, --& State: - Zip Code: 0 C ?-1 v Telephone: f 81-C7 6� Contractor: , �j �� �,-� ;rS � L L C- DBA: t,. L_r La 51) Address: ' `\ ! L \A; \� (1 Q / City: Lik, '1�jjS(✓ State: \JTZ Zip Code: C)b 2 Telephone: O `l 0 / I�j'Z License Type:/t.t C License No.:OS-7 Expiration Date: ///30 10C I hereby certify that the proposed work will conform to the State Building Code and all other codes as adopted by the State of Connecticut and the Town of Montville and further attest that the proposed work is authorized by the owner in fee and that I am authorized to make application for a permit for such work as described above. ❑ By checking this box, I will follow the requirements of the 2005 NEC as the alternative compliance per section E3301.2.1 of the Residential Code, instead of the electrical requirements in chapters 33 through 42 of the Residential Code. Owner/Agent Signature: ^__ �_ \ Date: (0 1`i 109 Construction Value Permit Fees Building Value: Building Fee: Plumbing Value: Plumbing Fee: Mechanical Value: Mechanical Fee: Electrical Value: Electrical Fee: Total Value: Penalty Fee: C of 0 Fee: Plan Review Fee: State Ed Fee: Total Fee: .Revisrd•August 23,2W7 Town of Montville Building Department File Receipt Date: 26-Jun-09 Receipt No: 4651 Received From: Nelson Building Job Address: 75 Pires Drive Fees Collected State Educational Training Fee Cash: $0.00 Cash: $0.00 Check: $207.43 Check: $3.83 Check No: 7773 Short/Over: $0.00 Construction Value: $21,280.00 Demolition Value: $0.00 Received By Carmen Roberts OG/1,tyisrit Address: 75 Pires Drive ITEM OTY S/UNIT TOTAL Building Plumbing Mechanical Electrical BUILDING AREA New Construction SF $ 113.03 $ - $ Basement,Finished SF $ 22.96 $ - $ Basement,Unfinished SF $ 12.40 $ - $ - Crawl Sapce SF $ 9.30 $ - Interior Renovations SF $ 35.09 $ - $ - $ MANUFACTURED HOMES Ground Anchors SF $ 645 $ - $ S Basement SF $ 12.41 $ - $ - $ Crawl Space SF $ 9.31 $ - $ - S - AMENITIES Kitchen EA $ $ $ Full Bathroom EA $ - $ Half-Bathroom EA $ - $ - GARAGE Attached SF $ 54.35 $ - $ - Detached SF $ 69.53 $ - $ - Under SF $ 10.03 $ - $ - Carport SF $ 19.89 $ - MECHANICAL Warm-Air n Y/N _ Hot Water n YIN $ - Electric n Y/N $ _ Air Conditioning n Y/N $ ELECTRICAL SERVICE Upgrade Amps Overhead,new Amps $ Underground,new Amps $ - Subpanel EA $ 599.50 $ - Gen Set EA $ 3,850.00 $ - SOLID FUEL BURNING APPLIANCES Prefab Metal Fireplace EA $ 6,497.70 $ - Masonry w/lfireplace EA $ 7.096.65 $ - Masonry w/2 fireplaces EA $ 11,095.70 $ - Wood Stove,free standing EA $ 2.692.25 $ - Wood stove insert EA $ 1,859.77 $ - DECKS,PORCHES,SUNROOMS Deck 532 SF $ 40.00 $ 21,280.00 Porch SF $ 149.38 $ - Sunroom SF $ 176.90 $ - $ - POOLS 8 HOT TUBS Hot Tub EA $ 8,016.25 $ - $ - Inground Pool EA $ 21,37344 $ - $ - Above Ground Round EA $ 6,100.00 $ - $ - Above Ground Oval EA $ 6,019.75 $ - $ - Pool Heater EA $ 8,984.25 $ - Inflatable Type Pool EA $ 1,550.00 $ - SHEDS w/o electrical SF $ 22.00 $ - w/electrical SF $ 20.35 $ - $ - RENOVATIONS Roofing,Overlay SF $ 3.00 5 - Roofing,Strip 8 reroof SF $ 4.00 $ - Roof Sheathing SF $ 1.31 $ - Siding SF $ 4.50 $ - Windows EA $ 600.00 $ - ., Skylights EA $ 1,051.10 $ - Doors,Exterior EA $ 625.00 $ - OII Tank,275 Gallon EA $ - Oil Tank,550 Gallon EA $ MISCELLANEOUS CALCULATIONS TOTALS $ 21,280.00 5 - $ - $ - PERMIT FEE CALCULATIONS Construction Value Fee Building $ 21,280.00 $ 176.00 Plumbing y $ - $ Mechanical y $ - $ Electrical y $ - $ Working before Permit Issuance $ _ Certificate of Occupancy Fee $ 10.00 Plan Review Fee $ 17.60 State Education Fee $ 3.83 TOTALS $ 21,280.00 $ 207.43 Figures are based on the 2006 RS Means Residential Cost Data STATE OF DEPARTTLIE,VT pF ONNE R:TECUT HOME IMPROvE PROTECTION NELSON BU;.F 9v#.4Nli,C.ONTRACTOR 4Az 8 _ .- 5 �_� O?NRUCTION LLC .i.,,, ..".- .`, 382 LIC./ -," -1r. r^ REG N `"__ 05732 . .: Qui �,`` . v,:...y EXPIRES .\r , f2ii, i' '11% 0/2009 SIGNEDN ^>:.5.,).F.2,- ..... >` 3 r • C State of Connecticut il sg"', = Workers' Compensation Commission 7A ,t ) =tri / � Please TYPE or PRINT IN INK ' Proof of Workers' Compensation Coverage when Applying for a Building Permit for the Sole Proprietor or Property Owner who WILL NOT act as General Contractor or Principal Employer Applicant for Building Permit Name of Applicant for Building Permittge L of t GL.kI Ilex' -_ Property located at -7s Pi('_:-.) Or I e_ in the City/Town of DoV(,C.lQ CT 06010 Attest If you are the owner of the above-named property or the sole proprietor of a business doing work on the site of the construction project at the above-named property and you WILL NOT act as the general contractor or principal employer,you are not required to have workers'compensation insurance coverage. CHECK ONE (1) BOX ONLY and complete the following: LII am the OWNER of the above-named property.I WILL NOT act as the general contractor or principal employer. Signature of OWNER Applicant gI am the SOLE PROPRIETOR of a business doing work at the above-named property.I WILL NOT act as the general contractor or principal employer. Name of Business n JZ , S'()_ l C \ . \ C \ U.,. + L1',/„ 1-c__AAS,---e.___ L L C J Federal Employer ID#(FEIN) J (�1 Signature of SOLE PROPRIETOR Applicant \ ✓ �.Y S Town of Montville Building Department 310 Norwich-New London Tpke. Tel. 860-848-3030, Ext 382 Uncasville, CT 06382 Fax. 860-848-7231 CONSTRUCTION PERMIT APPROVAL Property Address Job Description The applicant is responsible for obtaining all of the required approvals checked off on this form. No building permit will be issued until all of the required signatures have been obtained. Required Approval Department Permit Issuance Approval III Tax Collector EL // - _ (/, 165 Required for all permits Cornments: ® WPCA, Administrative �� -ei . • . .. •,.: / 6)7' Required for properties on sewer . .. . ::. , Comments: ❑ WPCA, Operations When Required by WPCA :.,a F, Comments: III Planning &Zoning .0 X i A c/�1/c}�j Required for all permits ,/ , /4 1 . .. • ." '� ® Health Department Required for properties with septic systems-Not required for Plumbing,Electrical,Mechanical, Roofing.Siding,Windows&Doors Comments: ❑ Department of Public Works Required when project includes driveway work or certain drainage requirements Comments: ❑ State Dept of Transportation Required for Structures over 100,000 sq.ft.or with more than 200 parking •aces-Official copy of STC Certificate of Operation required-per CGS 14-311 Comments: II l �' Fire Marshal i jc t Required for all permits ` N Comments: i(----)I Lrilitil L.>-1 &a-August 5,2005 Town of Montville Building Department • Plan Review Form Date: 6//5_ Job Address: 75 PI re Job Description: /47/ X g Pim G Your permit application is being rejected for the items checked off or commented on. The required information must submitted for review(two sets are required) (C.G.S.29-252a.) This list is offered as a guideline only. It is not meant to be all-inclusive for every permit application,nor is it meant to take the place of the State Building Code. SUPPORTING DOCUMENTATION CONSTRUCTION DOCUMENTS Permit application not completed Plans required XPermit fee due S ) y 3 Proposed building or addition exceeds 5,000 square feet, plans must be Permit fee to be calculated stamped and signed by a Connecticut registered Architect or Professional Construction values required for each trade in order to calculate the permit fee Engineer Worker's comp.affidavit or worker's comp.certificate to be submitted Construction documents are required to be shall be sealed by a CT licensed Copy of contractor's registration or license required Architect or Professional Engineer(106.1.4) Copy of Major contractor Registration Required Means of egress plan required designating the number of occupants on every Construction permit sign-off sheet required with appropriate approvals,it shall floor and all rooms and spaces, travel distances, and door, stair, ramp size be the applicant's responsibility to obtain the required signatures calculations(106.1.2) Affidavit required from the holder of the registration or license authorizing you Architectural plans required to apply for a permit with their information Structural plans required Provide supporting documentation to show compliance with the 2003 IECC Mechanical plans required (www.ener codes.•ov Electrical plans required Two sets of construction documents required, this includes all engineering Plumbing plans required data,calculations and all other documentation(RI 06.1) Fire protection plans required Documents are copyright protected,provide original plans or a letter from the Use&occupancy classification not indicated on the construction documents designer authorizing the duplication of the plans Provide calculations for the mixed separated uses(302.3.2) Field set of the approved construction documents are required to be picked up Height&area calculations required from our office and must be available on site during all inspections Ventilation calculations required to be submitted Construction documents shall be of sufficient clarity to indicate the location, More detailed plans required addressing accessibility nature and extent of the work proposed as per section R106.1.I Soils report not submitted(1802.6) Construction documents do not match the orientation of the structure on the Statement of special inspections required(1704), available online at www.ct- site plan sec.org Plumbing fixture calculations required STRUCTURAL DESIGN Construction type not identified Submit supporting data to show conformance with the wind limitations (3 Group classification not identified second gust @ 115 mph) Fire-resistance design must be documented by an approved source, Documents required to be stamped and signed by a CT registered Professional Building trap location&detail,not provided or insufficient Engineer Construction documents do not match the engineering data submitted SITE PLAN Ground snow load(Ps)for Montville is 30 psf No plans submitted or insufficient information MCE Spectral accelerations for Montville are; Plans do not match the building plans S,=0.255 Finish floor elevation not indicated Si=0.078 Distance from the property line(s)to the structure not identified Proposed structure or addition exceeds the "threshold limits" and an Stricture dimensions not provided independent structural engineering consultant review and all fees for such shall Existing and proposed contours are not provided or insufficient be paid by the of the building project(106.1.5.1) Design loads not indicated(live&dead) Footing drain discharge not identified Utilities no[provided(electrical,phone,cable,sewer,water,gas) FOUNDATION Delineation of flood hazard areas and design flood elevation is required per section R106.1.3 No plans submitted or insufficient information Private sewage disposal system to be identified along with all technical and soil Dimensions required data as per section RI06.2.1 Wall thickness not identified Grading is to slope away from the building,provide more detailed information Footing size not identified Plan submitted is not the same plan that has been approved by the Zoning Frost protection not identified or is insufficient Department and/or Health Department Column type,size,spacing not identified or insufficient Retaining wall—construction documents required Waterproofing details not provided or insufficient Retaining wall documents required to be stamped and signed by a Connecticut Pier type,size and anchor details not provided or insufficient Registered Professional Engineer Engineered foundation plan required Crawl space ventilation,location,type and size not provided or insufficient Crawl space access,location and size not provided or insufficient Jt evised May 4,2037