HomeMy WebLinkAboutChimney Work 2007 Field Inspection Notice Town of Montville Building Department January 4, 2008 Address: 70 Pires Drive Job Description: Rebuild Chimneys Permit Number(s): B2007-0595 Permit Date: October 4,2007 Not Approved Approval INSPECTION Date: Deficiencies Special Date Conditions • Existing chimney removed down to smoke chamber, • condition revealed charring at sheathing. Existing Chimney 12/19/07 DJ Reconstruction of chimney required from damper up. 12/21/07 DJ throat Wall ties and proper spacing required at sheathing. Reconstruct the throat and call for inspection. • Final Inspection for • • 1/04/08 DJ certificate of approval Final inspection for • • certificate occupancy Notice: Before a certificate of occupancy can be issued, a CIO signoff sheet must be completed and returned to the Building Department. Signoff sheet are available in the Building Department. Rev.Date: 1/18/06 Page 1 of 1 0EC-19-2007 10:03 From: To:318608487231 Pa9e: 1'6 -7o PiieS CrivQ- e � • To: Vern •m: George Clark Customer Relations Attn: Same Olympia Chimne Supply, In• Fax 860-848-7231 300A Brook St. No.: Scranton, PA 18545 Date: 12-18-07 Office: (800) 569-1 25 Ext 118 Re: Rich Bruynccl Job Office: (570) 504-71 18 direct di;1 Fax: (570) 504-7144 Pgs. 6 E-mail: gc1ar1@o1 piachirnney corn http: www.ol . .'.chimn- .com Cc: Vern, This fax is to give you the requested specs or Forever Flex liner to . - used on the above mentioned job being installed by Richard Peavey. I hope ou find this information useful 4-eorge Clark Ad, • ' 1 I ! a/9/0 7 DEC-19-2007 10:03 From: To:918608487231 Paae:2/6 Mil 0 Elm Olympic Chimney Supply Inc. P.O. Box 29 - Scranton,PA 18501 (570)496-8890 - F (570)496-8894 2-27 01 To All Building Inspectors, Olympic Chimney Supply is a manuf= er of single wall, stainless steel, chimney lining systems. Our FOREVER FL DX system is ITL tested an listed for all fuels(oil gas and solid fuels(wood, pellet, cos )). Our UL file number s DDZR.MH2i5852. Please see our comprehe -ive installation and main ce broth . which is included with each system for all ins,: lation requirements. Since Olympic Chimney Supply only ells its products to experi need qualifie installers, it is the responsibility of the instal le to insure that all national and local co. •s are followed This includes the proper liner s" ing for any given appliance. When siz ng issues arc discussed we always refer installersthe national oil and gas code manual- published by the National Fire Protection Ass kation. Be assured that safety is our number o.e concern no matter where our systems are being installed. If you ever have need of furth-r information please do nLt hesitate to call. Ret , r Christopher R. o .iffinan, VP, Olympic Chiron-y Supply DEC-19-2007 10:03 From: To:918608487231 Pa9e:3'6 DDZR.Guidelnfo- Liners 7 _age 1 of 2 COUnderwriters Laboratories inc.- DDZR. uidelnfo Li ers View LiMjnj Page tlotthm, Print-frien_ version. Qucstione ( Previogs Page J [Chimneys, Fireplaces, Vents an . Solid Fuel Burn i g AppLances] (Chimne s) Liners SeeQeneral Information for Chimn _‘Eirep[ace,Vents andSolidFuelB rning Appliances The chimney liners covered in this category are inte ed for installation, (1)as : ternate lining systems for fire clay flue linings (as described in ASTM C31 ) or(2)in the fire clay flue inings in mas)nry chimneys constructed in accordance with the Stands. of the National Fire Prot= tion Association for Chimneys, Fireplaces, Vents and Solid l uel Burning Appliances, NFPA 211, or.pplicable model building code requirements. Separate chimney liner parts required for installation f chimney liners are speci ted in the installation instructions provided with the chimney liners. UnIes, specified in the individual r istings,thest chimney liners are intended for use with gas, liquid and solid • el fired residential type : building heating appliances specified in the Chimney Selection Chart f the National Fire Protec on Association Standard NFPA 211. The basic standard used to investigate products in thi. category is UL 1777, "C. . ey Liners" . The Listing Mark of Underwriters Laboratories Inc. n the product is the only m thod provided by Underwriters Laboratories Inc. to identify products p educed under its Listing at Follow-Up $crvice. The Listing Mark on these products includes the nun . and/or symbol of Und- 'ters Laboratories Inc. (as Illustrated in the Introduction of this Directory)to.ether with the word "LIS ED" , a control number,and one of the following product names as a•propriate: (A) "Chimney iner," (B) "Chimney Liner Part Intended For Use With (Company Name) I istcd Chimney Liner Parts' , (C) "Chimney Liner Material Intended For Use With(Company Name) Li.ted Chimney Liner Parts" or(D) "Chitxmey Lkner Part." Each Listed Chimney Liner section bears a Lis ling Mark with a product n- .e similar to :A); when a combination of proprietary parts or materials ..re required to complete the chimney line installation, the part or material hears a Listing Mark imilar to (B) or(C); and e.ch additional part bears a Listing Mark with a product name similar to (D). Less ; dated on 1988-08-11 PAP.Top Notice of Disclai er Questir s? ( Previous Page I UL Listed and Classified Ui. R cp rniz• Products Certified r http://database.ul.corn/cgi-bin/XYV/template/L'SEX /1 FR.AME/showpage.html.&name=... 2/4/2005 DEC-19-2007 10:03 From: To:918608487231 Page:4/6 i • !:. , . ::; . .. ,',. .31„ .,..: E „. , , , , 4 ,.) ; . • Stainless Steel Chi ney Lining ystem Product Information The Forever Flex stainless steel lining system is available in 3"to 16"diameters. The lining system must be installed by a qualified chimney or venting professional. The criteria for installation must be in conformance wilt the specifications contained in the latest versio of the NFPA 211 (Standard for Chimneys,Fireplaces, Vents and Solid Fuel Burning Appl anees)and local 'r state building codes, whichever has jurisdiction. Convict local building or fire oflricia s about restrictions and installation inspection in your area. It may be neces to obtain installing the chimney liner. Contact the local buildin authority for permit infonnatio rmits before Product Applications The Forever Flex lining system(A F-316Ti or HG-A 29-4C)is intended for use with heating applian.-s burning home heating oil,natural or LP gas and solidfuels(pellet,wood and coal)ven through a masonry chimney. Use of experimental fuels is not pe irted and voids the warranty, his lining syste is not intended for use with Category H, Ill,or TV gas b ing appliances as defined by th National Fuel e:s Code,NFPA.54,or other appliances that cause conden tion of corrosive acids on the 1' er of the chimn:i, or that create positive pressures in the chimney system. The Forever Flex system is intended for use in(1)an u lined chimney with at least(a n urinal)4"of masonry all around,(2)a properly built masonry chicon y with cracked clay tile liners, d(3)to provid• a properly-sized flue for a heating appliance installed in a masonry chimney that atherwis meets existing codes. The Forever Flex liner may also be used as a flue for a replace. The liner must be co ected to the top f- the smoke chamber by means of a bottom plate or other means,which provides an air-ti t and drip-free termination, Specifications- • Thickness: .005 or .006 (specify when orderi g) Alloy 316Ti : (Typical Analysis (by %): Car on .03, Manganese 1.78, P osphorous .0., Silicon .45, Chromium 16.85, Nickel 10.55, lybdenum 2.08, Titanium 25, Bal. Iron Optional AL 29-4C alloy:(TvpicalAnalysis(by%): arhon .02,Manganese .50,Phos•harous.03,Sul, r <0.01, Silicon.35,Chromium 29. Nickel .30,Molybde int 4,Nitrogen.02,1'iwniumtC 1lumbium.60, Hal. iron Diameters available: 3,4, 5, 5.5, 6, 6.5, 7, 8 9, 10, 11, 12, 14, 16 Seam: 7-ply air and water. tight Olympic Chimney Supply, 300A Brook Street, Scranton,PA 18505 57O-496i8890 DEC-19-2007 10:04 From: To:918608487231 Page:5/6 DDZR.MH26852- Liners : • Page 1 of 2 13 Underwriters Laboratories inc. DDZR.M1-126852 Liners Page Bottom Print friendly version Q!cstions? Previo Page Liners See General information for Liners OLYMPIC CHIMNEY SUPPLY INC M1126852 300A BROOK ST SCRANTON,PA 18505 LISA 1 '' Model "FOREVERFLEX-AF", flexible, chimney lin r system, sizes 3, 4, 5, 5-1/2, 6, 7, 8, 9, 1a), 11 and 12 in. diameters. Intended for use in masonry chimneys used to vent gas, liquid, or solid fuel fu'ed residential type appliances. ,r Model "FORF:VF,fu LEX-HG", flexible, chimney lin r system, sizes 3, 4, 5, 5-1 , 6, 7, 8, 9, 1 ), 11 and 12 in. diameters. Intended for use in masonry chimney:; used to vent gas, liquid r solid fuel find residential appliances. 1 i Model "RHINO RIGID",rigid chimney liner system, sizes 3, 4, 5, 6, 7, 8, 9, 10, l 1 and 12 in. 4iametcrs. Intended for use in masonry chimneys used to vent gas, liquid or solid fuel fired i esidential appliances. 1 Model "ARMOR FLEX", flexible chimney liner system, sizes 2, 3,4, 5, 6, 7, 8, 10, 11, and I2 in. diameters. Intended for use in masonry chimneys used to vent gas, liquid or solid fuel fired residential appliances. Minimum installation height is 8 ft and maximum installation height is 75 ft. Min. clearance Mih clearance fror;♦i lining to from misonry chimney Fuel Insulation masonr4 chimney (in.) to con>ibustibles (in.) Gas, Liquid or Solid Yes* 0 0 Gas or Liquid No 1, 0 I 0 *- Optional for gas and liquid. http://database.ul.comlcgi-t in/XYV/templatefLTSFX'l'/1 FRAME/showpage,htmlr�name=DD... 2/4/2005 1 DEC-19-2007 10:04 From: To:918608487231 Pa9e:6'6 • . File MH26852 Vol. 1 ,Sec- 1 Page1 IsA4d; 2000-1o726 and Report Reviled- 2004-08. 11 DESCRIPTION f PRODUCT COVERED: I USL - Modell u FOREVERFLEX-AF ^ and "FOR VERFLF.X-HC°, tleJib1 , stainleSs steel Chimney liner systems_ ENGINEERING CONSIDERATToNS (NOT FOR FIELDRFPR135ENTATIVE'S USE) • UsT., - Denotes conformance to the UJ Standard For Chimney L'ners, UL 1777, Third Edition_ GENERAL: ; The t..exible, metallic chimney 14 me are intended 110 be installed in new or exieting masonry chimneys ueed to vent gas, :tiguid, or Solid fuel fired residential type and hnilidinu heating appliance,. The liners are manufactured iti 3 through 12 icy. diameters. The flexible chimney liners are intended for installation in masonry chimneys having a minimum height of 8 ft. and a maximum height of Vi ii... Ii The following table provides minimum clearance details :tor the Chimney .LLr.f' ir:ye tti. 1 Fucl(si Insulation Minimum cicurunce From Minim m Clearance Lining; To Masonry FromMalponry chimney k Chimney (in.) To Combustibles I kin.) Gas, Liquid or ._.. --YA.p. I 0 Solid I 0 Cls or. Lj.c �i r9 l o I 0 - - �Ir----.. I A Classified. (10(NV) , j mil. , foil•felced, Calcium-MagnesiumSilicate insulation by Unifrax Corp. , with minimum I1/2 in. thick, 8# density blanket or two (2) 1/4 in. thick, 8# density blankets may be wrapped arouilnd the entire length of the liner system in a ma4onry chimney to provide zero Cl.ea:Carce between combueLiblc materials arid the chimney exterior.; I I I As an alternate, A Classified (BKNV)I, 3 mil. , foil-faced, Calcium- Magnesium Silicate ineuiar.inn by Thermal r,erumice with minimum 1/2 in. thick, 8# density blanket nr two (2) 1/4 in. thick, 84 density blankets may be wrapped around the entire 'length of the liner System in a masonry chimney Lu provide zero clearance between combustible materials and the chi ey exterior. I 1 The flexible chimney liner system re,g1 ire. the usz of a bas tee, top p.lilL e, +�iappc,rt. r.�l.irk-,, storm collar and rat�n cap. i 1 I I I TOWN OF MONTVILLE Building Department 310 NORWICH-NEW LONDON TURNPIKE UNCASVILLE, CT 06382-2599 TEL. (860) 848-3030 X382 FAX (860) 848-7231 BUILDING PERMIT Permit Number: B2007-0595 Date: 04-Oct-07 Map/Lot: 039/084-000 Owner ID: 5526000 Project Location: 70 PIRES DRIVE Unit: Job Description: Rebuild Chimneys Owner Name: Richard W and Josephine Bruyneel Tenant Name: N/A Careof: 70 Pires Dr Oakdale CT 06370- Telephone: Contractor Name: Rich Peavey ..._ Telephone: (860)332-3800 DBA: Stonington Masonry Lic/Reg Type: HIC P.O. Box 1059 rt Lic/Reg No: 60845 Exp Date: 30-Nov-07 Pawcatuck CT Construction Value Permit Fees Construction Information Building Value: $11,650.00 Building Fee: $96.00 Use Group: IRC__ Plumbing Value: $0.00 Plumbing Fee: $0.00 Code: 2005 State Building Code M1 Mechanical Value: $0.00 Mechanical Fee: $0.00 Electrical Value: $0.00 Electrical Fee: $0.00 Construction Type: IRC Total Value: $11,650.00 Penalty Fee: $96.00 Permit Code: R4 C of 0 Fee: $0.00 Comments: Plan Review Fee: $0.00 State Ed Fee: $1.86 Total Fee Paid: $193.86 It shall be the owners repsonsibility to schedule the following inspections a minimum of 2 business days in advance: Field set of approved construction documents shall be available onsite during all inspections. BUILDING PERMIT INSPECTIONS PLUMBING, MECHANICAL, ELECTRICAL PERMIT INSPECTIONS Footing- Prior to pouring concrete R Plumbing and leak test Deck Piers R Electrical Backfill - Footing drains and waterproofing Elec Trench -with conduit installed Concrete Slab- Prior to pouring concrete Pool Bonding Anchor Bolts-with sill plate and prior to floor framing Electrical Service CRS No: 0 Framing R HVAC V Masonry Fireplace Throat or Chimney Thimble Gas Piping and leak test Fireblocking_Draftstopping INSPECTION REQUIRED UPON COMPLETION Insulation • icate of Appr. :I Ce • .ccupancy Building Official's Approval: ; I . • Town of Montville Building pepartment 310 Norwich-New London Tpke. Tel. 860-848-3030, Ext 382 Uncasville, CT 06382 Fax. 860-848-7231 RESIDENTIAL PERMIT APPLICATION FORM Permit No.: 11007-05C1S Type of Work Occupancy Type Permit Type ❑New Construction Single Family Building ❑Addition [JTwo-Family ❑Plumbing ;81 Alteration 0 Townhouse ❑Mechanical n ❑Accessory Structure 0 Electrical CRS#: Job Address: '!0 /11.i / iQ ive_ r' K A 1,e cI r( ?7 0 (Number) (Street) (Unit) Job Description: ie( 84'i t.) 0 f �1/n( Af! Vs Owner: Ac11 A-n_ t2 PuYA/ i— Address: 7 I (f<rS iJ/ _ City: ��P f�C�ri C ? State: c Zip Code: C) 0 Telephone: (%0 `,L ?6 S-G Contractor: el CA t' -v e - ¶ t0A//4/6 /�/I/ 44 SD Al4)`./ DBA: Address: /9or 13c,x L r e / City: 11411-L-) 1 LL'c 1 f'Li_ 't o State: C /t� Zip Code: Telephone: (5"6„6, 332 gYCtT License Type: 4.1..d... License No.: CC WV') Expiration Date: I hereby certify that the proposed work will conform to the State Building Code and all other codes as adopted by the State of Connecticut and the Town of Montville and further attest that the proposed work is authorized by the owner in fee and that I am authorized to make application for a permit for such work as described above. By checking this box, I will follow the requirements of the 2005 NEC as the alternative compliance per section E3301.2.1 of the Residential Code, instead of the electrical requirements in chapters 33 through 42 the Residential Code. - / Owner/Agent Signature: �'` C'L/ / t Date: /(.." c�( / 7 Construction Value Permit Fees /// Building Value: Building Fee: Plumbing Value: Plumbing Fee: Mechanical Value: Mechanical Fee: Electrical Value: Electrical Fee: Total Value: Penalty Fee: C of 0 Fee: Plan Review Fee: State Ed Fee: Total Fee: ftvisaAugust 23,2007 Town of Montville Building Department File Receipt Date: 03-Oct-07 Receipt No: 2843 Received From: Richard Bruyneel Job Address: 70 Pires Drive Fees Collected State Educational Training Fee Cash: $0.00 Cash: $0.00 Check: $193.86 Check: $1.86 Check No: 3800 Short/Over: $0.00 Construction Value: $11,650.00 Demolition Value: $0.00 Received By Carmen Roberts C/; 'n/� ,� ,n nn akleitirW 11��` �' yt1 ' F Town of Montville Building Department 310 Norwich-New London Tpke. Tel. 860-848-3030, Ext 382 Uncasville, CT 06382 Fax. 860-848-7231 CONSTRUCTION PERMIT APPROVAL r/c7-, 6 (,)? s M C79-i0)44::( Property Address, A/// ( , C' l&lcf! Job Description The applicant is responsible for obtaining all of the required approvals checked off on this form. No building permit will be issued until all of the required signatures have been obtained. Required Approval Department Permit Issuance Approval ' 1( Tax Collector !-�•__—_�/V •�. /°/-q° 7 Required for all permits Comments: ® WPCA, Administrative Required for properties on sewer Comments: ❑ WPCA, Operations When Required by WPCA Comments: Planning &Zonin7 -7,z y,,, /e 3/c 7 Required for all permitsJ /— ® Health Department Required for properties with septic systems—Not required for Plumbing,Electrical, Mechanical,Roofing,Siding,Windows&Doors Comments: ❑ Department of Public Works Required when project includes driveway work or certain drainage requirements Comments: ❑ State Dept. of Transportation Required for Structures over 100,000 sq. ft.or with more than 200 parking spaces-Official copy of STC Certificate of Operation required—per CGS 14-311 Comments: i Fire Marshal 9 'Irk Required for all permits , Comments: I N L�L" 4 U .( - ftvisedfiugust 5,2005 vow •,� State of Connecticut Fl 7A YLL`+� x r Workers' Compensation Commission J: Please TYPE or PRINT IN INK Proof of Workers' Compensation Coverage when Applying for a Building Permit for the Sole Proprietor or Property Owner who WILL NOT act as General Contractor or Principal Employer Applicant for Building Permit Name of Applicant for Building Permit Ac°,11 Property located at 70 r ( 1 l-( S J 4 ( V in the City/Town of OA / i 4 1.P Attest If you are the owner of the above-named property or the sole proprietor of a business doing work on the site of the construction project at the above-named property and you WILL NOT actas the generafcontractor or principal employer,you are not required to have workers'compensation insurance coverage. CHECK ONE (1) BOX ONLY and complete the following: aI am the OWNER of the above-named property.I WILL NOT act as the general contractor or principal employer. Signature of OWNER Applicant ❑ I am the SOLE PROPRIETOR of a business doing work at the above-named property.I WILL NOT act as the general contractor or principal employer. Name of Business Federal Employer ID#(FEIN) Signature of SOLE PROPRIETOR Applicant I; r®P .5at Page# of pages Li -.7:,, ,....c. "," d/V3 4 TtIC'4 I- OCJ -dS9 \-;--.1` 4') i4C44 2:INK‘ 6.7c.4re�C/C c/ ., t.„...,eS r---- �- Proposal Submitted To: Job Name Job# AddressJ Job Location Date Date of Plans Phone# 'Fax# Architect We hereby submit specifications and estimates for: . ........_... 1 •_ ., ..ec32x) .i)rf ..,Zz,A-e 7:g07<_. .64/.4teeeofoc.- -1 • e� • ._ 7`--` :.d '`kms. _ .1..._ , u.Z.s_ .._ "(SD . LYS c° • o o - ...zijeo , Fr' i x/i2ce, , e)0 _./"..4.5-elee4dyy-7,9.),/ 1}1Q/ /3' Tye) 0. 07-57 Zi/se . 6....c) '714:1, z-iire. eV-- .:: ,0,4).k.e ce*.;_ts_-",41--.. atz er7.e.vE.)." .fry .._do... 3 7 _ cf/ o , vo 42 774'x_. - .. . /rp / / __ , •'c r _ .&i..-..,,,,47 .E.:- __ ',�0;`1 ‘,6y402.4._ . d) a/ D__.0L-8--- 46-4.,....e 1/;,):.e.ilei, ,,,,,zetrzer-i- iiviivAixd7?-eiti et}---- r?-,e6 t'zcz z"-ve-/L 1J7 , 497 1 r /9.4a We propose hereby to furnish material and labor—complete in accordance with the above specifications f e sum o • / rs with payments to be made as follows: �' •"e, --"'A-re 42,4,/Z 'De) '" r Any alteration or deviation from above specifications involving extra costs will be Respectfully ' .440"r /--/ executed only upon written order, and will become an extra charge over and tt ,f----r above the estimate.Ali agreements contingent upon strikes,accidents,or delays submit ed beyond our control. Note—this. oposai .• .e withdrawn by us if not. ce. - 'within days. ::�_• Ziceeptanee of Vr 1 t o5it The above prices,specifications and conditions are satisfactory and are hereby accepted.You are authorized to do the work as specified. Sign ure Payments will be made as outlined above. Date of Acceptance \ p Signature ; at NC3819 lit i O O � Page# of pages I - s �C1/ , ' z JLLL'( e7 f),-..ie-- ,. . ,,, ,, ,,, ,„ 7„,, ,r Proposal Submitted To XavdAo_eziJob Nog Job# , ,,.< /1,4...,e/24-, Address Job Location ,,e7:7",/7-/ja..4:- ,_ Date Date of Plans Phone# • Architect \ Pfr- / ) \ We hereby submit specific. ons and a 'mates for:__ . .a, ,eikyed, ''',,,,;,,q,-;,144- .4,....". ..._—_ t,/1....le 6.".....1/... ' er)IlL j d 4 . ,,,,,/,.....4g._ ("2,,,t4,/ .,e,:‘,A4e- a-,' ,i/ til:/g9il Eyzty.e/VI ,L,42,-"Ve .40° ' /z1. . ,ee dd e&cf/,a.0 i✓5-7/9,1,ZrAe."1 Gf 0 diewTC-✓f W a/E.e ..__4 ?5-449 4.0fs _.._._. ...... _._. 16-4/4 (24""le-Y ------Z " i-fler ,.1?1(5" ...._l_S_4. ,,may_ .... _....G. ✓eee, .f 4;.2..)-7-7._ _ . _._fir" ......... .... ..... . ....... _. lee er D‘Sv,. off ..ort��,e . \ / \ We propose hereby to furnish • and labor—complete in accordance with above specifi tions for the sum of: $ / �� /isd/t/ / re Dollars with payments to be made as follows: / _ ii Any alteration or deviation from above specifications involving extra costs will be Respectfully executed only upon written order, and will become an extra charge over and submitted — above the estimate.All agreements contingent upon strikes,accidents,or delays / 4 beyond our control. Note—this p . may be withdrawn by Pr not accepted within_ days. ( I 2cceptance of 'Iaromo at The above prices,specifications and conditions are satisfactory and are Signature hereby accepted.You are authorized to do the work as specified. Payments will be made as outlined above. f LDate of Acceptance Signature e °:NC3819 Address: 70 Pires Drive ITEM CITYSIUNIT TOTAL Building Plumbing Mechanical Electrical BUILDING AREA New Construction SF $ 114.17 $ - $ _ Basement,Finished SF $ 20.87 $ - $ _ Basement,Unfinished SF 5 1128 $ - $ _ Crawl Sapce SF $ 8.46 $ - Interior Renovations SF $ 31.90 $ - $ - $ _ MANUFACTURED HOMES Ground Anchors SF $ 5.86 $ - $ - $ - Basement ': SF $ 11.28 $ - $ - $ Crawl Space ': SF $ 8.46 $ - $ - $ - AMENITIES Kitchen EA $ - $ $ Ful Bathroom :, E,q $ $ Half-Bathroom f EA 5 - $ GARAGE Attached SF $ 49.41 $ - $ _ Detached SF $ 63.21 $ - $ _ Under SF $ 9.12 $ - $ _ Carport SF S 18.08 $ - MECHANICAL Warm-Air Y Y/N $ - Hot Water N Y/N Electric N:,',',I,' YIN $ - Air Conditioning N'..,< YM $ - ELECTRICAL SERVICE Upgrade SS'Amps $ - Overhead,new Amps $ - Underground,new :Amps $ - Subpanel EA $ 545.00 $ _ Gen Set : EA $ 3,500.00 5 _ SOLID FUEL BURNING APPLIANCES Prefab Metal Fireplace EA $ 5,907.00 $ - Masonryw/lfireplace EA $ 6,451.50 $ - ' Masonry w/2 fireplaces EA $ 10,087.00 $ - Wood Stove,free standing EA $ 2,447.50 $ - Wood stove insert EA $ 1,690,70 $ - DECKS,PORCHES,SUNROOMS Deck SF 5 39.16 $ - Porch SF $ 135.80 $ - Sunroom SF $ 160.82 $ - $ _ - POOLS&HOT TUBS Hot Tub EA $ 7,287.50 $ - $ _ Inground Pool ` EA $ 19,430.40 $ - $ - Above Ground Round EA $ 4,635.88 $ - $ _ Above Ground Oval EA $ 5,472.50 $ - $ _ Pool Heater ': EA $ 8,167.50 $ - Inflatable Type Pool EA $ 1,542.42 $ - SHEDS w/o electrical SF $ 18.50 $ - w/electrical SF $ 18.50 $ - $ _ RENOVATIONS Roofing,Overlay SF $ 3.38 $ - Roofing,Strip&reroof ': SF $ 3.76 $ - Roof Sheathing SF $ 1.19 $ - Siding ': SF $ 2.30 $ - Wiindows EA $ 423.50 $ - Skylights : EA $ 955.54 5 - Doors,Exterior EA $ 401.50 $ - Oil Tank,275 Gallon EA $ - Oil Tank,550 Gallon ` EA $ - MISCELLANEOUS CALCULATIONS $ 11,650.00 TOTALS $ 11,650.00 $ - $ - $ - PERMIT FEE CALCULATIONS Construction Value Fee Building $ 11,650.00 $ 96.00 Plumbing Y $ _ $ _ Mechanical Y $ _ $ _ Electrical Y $ _ $ Working before Permit Issuance y $ 96.00 Certificate of Occupancy Fee $ Plan Review Fee $ State Education Fee $ 1.86 TOTALS $ 11,650.00 $ 193.86 Figures are based on the 2006 RS Means Residential Cost Data 3 Oct 2007 SUBJ: Notice of Violation Document received from Town of Montville dated 28 Sept 2007. ENCL: 1. Proposal from Stonington Masonry, 28 July 2007 2. Detailed Proposal from Stonington Masonry, (early August) 1. We have a licensed contractor planned to perform to work at 70 Pires Drive. The contractor is licensed(#60845) and insured. The contractor is responsible to handle all the administrative work (including filing the permit paperwork)per our agreement. 2. No work has started on the chimney towards the re-building. The only work performed so far is what was necessary for the contractor to provide a detailed proposal. Removing the chimney to the roof-line was necessary for the contractor to itemize in detailed form what was necessary. I requested a firm fixed quote from the contractor and he could not provide this without removing the chimney to the roofline. The removal of the chimney to the roofline took place in early August. 3. The work to Re-build the chimney is not to start until 1st week in Nov or Maybe Oct sometime. Regardless, the contractor is responsible to get the Permit paperwork in place with the town hall. 4. No building materials are on-site. No Bricks, No mortar/cement material and NO stainless steel sleeves are on-site. This is because the materials have not been ordered. 5. In light of the current situation, I will provide the proposals which I hope are detailed enough and I'll submit for the permit, even though I'm paying the contractor to do this. In summary .... No work toward the re-build of the chimney has started, the only work that has been done was that to provide a detailed proposal for a firm fixed price to repair the chimney. No building materials are on-site or ever have been toward this chimney, the parts have not been ordered yet to the best of my knowledge. v/r Rich Bruyneel Cell# 860-334-8850 I have paid a deposit of$5,200.00 and owe a balance of$6,450 upon completion. TOWN OF MONTVILLE Building Department 310 NORWICH-NEW LONDON TURNPIKE UNCASVILLE, CT 06382-2599 TEL. (860) 848-3030 X382 FAX. (860) 848-7231 9/28/2007 Richard W and Josephine Bruyneel 70 Pires Dr Oakdale CT 06370- Delivery method: REG.JLA _4 IL NOTICE OF VIOLATION for the property located at: 70 PIRES DRIVE Unit: Map/Lot: 039/084-000 You are hereby ordered to discontinue the violation at the above referenced property per Section R113.1 of the 2005 Residential Code as adopted as the Connecticut State Building Code You must STOP WORK as per Section R114.0 of the 2005 Residential Code as adopted as the Connecticut State Building Code and you must submit to the Building Department a plan of compliance within ten (10) calendar days from the date of receipt of this notice in order to avoid possible legal action. The violation consists of: Repair of a chimney without Permit(s) and Approval(s) zICry ii Charles CoreII Building Inspector Cc: Town Attorney File Office Use Only: Date: Inspector: Comments: