HomeMy WebLinkAboutWoodstove 1994 •
TOWN OF MONTVILLE
/4' . .9
0 '
Building Department / ' �
848-716641:4
APPROVED BUILDING PERMIT OR TRADES PERMIT
For 180 Days
Permit No: 11829 Approval Date: 10/5/94 Expiration Date: 4/5/95
Estimated Cost: 1 ,000 .00 Fees: 10 .00 PRF: 1 .50 C .O: 5 .00
Owner : Clement W . Brown ,Jr . Address: 22 Pires Drive Tel : 848-9833
Job Location: 22 Pires Drive Code: 05
Contractor : self Address: same
Tel : same
Stick Built: x Modular Home: Manufactured Home:
Commercial :
Addition: Garage: Car Port: Shed:
Remodeling: Roofing:
Siding: Fireplace: Chimney: Windows: Pool : Demolition:
Plumbing: Heating: Electrical : Air Conditioning: Gas:
Patio: Porch: Deck: Retaining Wall : New: x Repair/Replacement:
Type of material used/description: install wood stove to existing flue - 8 " x
8 "
Size: Type of Heat:
Fireplace:
No .of Stories: No . Rooms:
Breezeway:
No . Baths: Garage:
Use:
I hereby certify that the proposed work will conform to the Basic
Building Code and all other Codes as adopted by the State of Connecticut , and
the Town of Montville.
Applicant 's Signature: ac -;>4
4111 Date : 0.5oe_7-
If signed by Contractor , type of Ucense/registration & No: <2
Building Official 's Signature: 1 ,
/.. ,...__ , Date: �4.�v//
/9
Date of Health Dept. Approval : 043/41P-
lOr
Date of Zoning Approval : �G
,;/97-
THIS IS TO INFORM YOU THAT UNDER THE CONNECTICUT AMENDMENT OF THE
BUILDING CODE, SECTION 119 .3 A CERTIFICATE OF OCCUPANCY IS REQUIRED PRIOR TO
ANY USE OF THE STRUCTURE .
A MINIMUM OF 24 HOUR NOTICE TO THE BUILDING DEPARTMENT IS REQUIRED FOR
INSPECTIONS .
TOWN _OF MONTVILLE
Building Department
Application for a permit
Owner: ��+=-vvt�- W, 3�2owV 31? � L tLC , 0657O
Address: 2 2 ��2F5 � 1 Tel : 4g-c g33
Job Location: -��✓e..
Contractor:
Address:
Stick Built: ------ Tel :
Modular Home: ✓ Manufactured Home:
Commercial :
Addition: Garage:
Car Port: Shed: Remodeling: Roofin
Siding: g:
Fireplace: Chimney: Windows:
._._ Pool : Demolition:
Plumbing: Heating: _ Electrical :
_ Air Conditioning: Gas:
Patio: Porch: Deck:
Retaining Wall : New:
Type of Material/job description: — Repair/Replacement:
Size: Type of Heat:
Fireplace:
No. of Stories:
No - Rooms:
Breezeway:
No. Baths: Garage:
Use:
•
azte,k4
This Manual describes the installation and operation of the Model No. S244E/EP S245E/EP noncatalytic wood heater.This heater
' meets U.S. Environmental Protection Agency's emission limits for wood heaters sold after July 1, 1990. Under specific conditions
this heater has been shown to deliver heat at rates ranging from 10,467 to 24,020 BTU per Hour.
l'
. 6" FLUE REQUIRED
Model No. S244E/EP S245E/EP FIG. A. CLEARANCE FROM COMBUSTIBLE CONSTRUCTIONS
"''This unit has been listed by
Warnock Hersey Limited to From Heater From Chimney Connector
meet or exceed ULC S-627 Canada U.S./Canada U.S./Canada
and UL 1482 U.S. A Sidewall 18" (457 mm) D Sidewall .... 25-1/2" (648 mm)
B Backwall 15" (381 mm) E Backwall ... 17-1/2" (445 mm)
C Corner 7" (175 mm) F Corner 15" (381 mm)
Unit must be placed on a non- Ceiling 56" (1422 mm)
combustible floor protector equivalent BACKWALL BACKWALL
to 318"millhoard.
Consult your local building authorities
for further information. f 1 '
E 8.. F'/1
Contact your local building inspector Q i I �•
prior to installation. ti
• `
A permit may be required in your area. 0 o ,'D � •
• \`,
•
IIINIMIIIMIW
f ,--.—FFLOOR PROTECTOR "1
•
•
MUST HAVE MIN. i e ,'
RVALUE OF.446 i_ • '
•L /
_._I 8"—.-- L
y e «CLOSED\\
® 0 t% . / 1
OPEN !
_ ,, _ _\_
; 0 N---_______---/
) vim ...)
�, — l
1 LA
PARTS LIST
# QTY. DESCRIPTION PART# FULL BRICK X 2 0 114\ . /01
1 1 DOOR ASSEMBLY(S244E/EP) S31008 I._1 _
1 1 DOOR ASSEMBLY (S245E/EP) S31144 CO j LEG OPTION
1 1 DOOR (NO GLASS) (S245E/EP) S31146 SHOWN
1 1 DOOR (NO GLASS) (S244E/EP) S31116 Ill
'BE SURE TO INSTALL TWO
2&3 1 GLASS AND GASKET S31117 -t:_-_-
,,-, `Ii�1�\ FULL BRICKS IN BAFFLE
3 4 ft. 1/8" GLASS GASKET ONLY S15001 `\- , AS SHOWN.*616040)
4 1 SPRING HANDLE S11007
5 1 AIR CONTROL SPRING HANDLE S11008
6 4-1/2ft. 5/8" DOOR GASKET ONLY S15011 1 BAFFLE
7 1 GLASS CLIP S37018 ASSEMBLY
8 2 SCREWS S11086 . 14 14 14 14I1'
9 1 BRASS BODY TRIM S32217 12 J 1P
10 1 BRASS ASH FENDER TRIM S32023
11 2 HINGE PINS (S244E/EP) S11005 12 12 12 12
11 2 HINGE PINS (S245E/EP) ONLY S11066 BRICK PATTERN
12 12 BRICKS 9" x 4-1/2" S16040
13 2 PUSH NUT S11090
14 4 BRICKS 7-1/4" x 4-1/2" S16043
15 2 BRICKS-ANGLED S16042 DECORATIVE BRASS TRIM
Be sure to remove protective plastic coating
after installing your wood heater.
I'
V INLET AIR CONTROL SETTINGS
0114
t -� Desired burn rate Inlet air setting **Approx. BTU output
Low Closed Fully 10,467
SPRING HANDLE Med / Low 1/4"Open 12,336
Twist spring handle in a counter clockwise Med / High 1/2"Open 17,111
motion while pushingon to handle; spring
Hlgh Fully Open 24,020
handle will "thread"down to desired location. **Performance may vary depening on actual home operating conditions.
Part No. S19212 Rev. 3 5/94 I NOTE: Retain this sheet for future reference
/ iedicif4a.
Lire avec soin les instruction suivantes avant d'installer le poele Modele No. S244E/EP S245E/EP non-catalytic. Cette poele
recount le Exgigences American pour L'Enveronment emission pour les poele solde entre le apres le ler Juillet, 1990. Sur
certain condition, ce poele a un pouvoir devait degage entre 10467 et 24040 BTU par heure.
Modele No.S244E/EP S245E/EP TUYAU DE CHEMINEE 6"
Cet appareil a ete enrequiste SHEM A. ESPACES ENTRE LE POELE ET LES CONSTRUCTIONS COMBUSTIBLES
par Warnock Hersey Ltee pour DEPUIS LE POELE DEPUIS LE MANCHON DE RACCORD
etre conforme ou &passer en U.S./Canada DE LA CHEMINEE U.S./Canada
CanadaULC S 627 et dans le A Mur lateral 18" (457 mm) D Mur lateral. 25-1/2" (648 mm)
U..S.S. UULL 1482. B Mur arriere 15" (381 mm) E Mur arriere 17-1/2" (445 mm)
C Coin 7" (175 mm) F Coin 15" (381 mm)
Plafond 56" (1422 mm)
L'unite doit etre place sur un protecteur MUR LATERAL
de plancher inflammable,consultez MUR ARRIERE
votre inspecteur en batiment de votre l
localite pour de plus amples ���`
information. -I---1-- I F
V
W E - I E4" Q ! \•
I `
Informez-vous aupres de l'inspecteur F I
7 lif •
en batiment de votre localite si un Q I • I g , OP •
\`
permis est requis. ¢ 1 � ``
D
+i
-m-F /
PROTECTEUR POUR LE \
PLANCHER FAUT
I I `• �
ETRE UNE MINIMAL `
R EVALUER DE.446 L �� '
/ «FERMEE\
F -,...• Er
la) 0 OUVERTII0
)
K,L \
/� , 0 -
11 'fr
- - — - ____ APPIPPF-
/X7'.,:; -Z I JI
-Z WI;
LISTE DES PIECES BRIQUE COMPLETE X 2 ;12 ----------- 1 LI ill 111 ill kPOP" 4I
N° OTEE DESCRIPTION N°DE PIECE I._I ` �l MODELE SUR
1 1 PORTE (S244E/EP) S31008 III
10 PATTES ILLUSTRt
1 1 PORTE (S245E/EP) S31144
1 1 PORTE (SANS LA VITRE) (S245E/EP) S31146 ill
1 1 PORTE (SANS LA VITRE) (S244E/EP S31116 . 'ASSUREZ VOUS DE BIEN INSTALLER DEUX
1
'' , � ����
� ,�\ BRIQUES COMPLETE DANS LE D(:Rwl
ECTEUR
2&3 1 VITRE DE JOINT SEULEMENT S31117 �r-'' �.. 11111111\
TEL QUEDEMONTRE.'Lsi6o
3 4 ft. JOINT 1/8" DE LA VITRE S15001 \+
4 1 POIGNEE S11007
5 1 POIGNEE PUR CONTROL D'AIR S11008 - --I
6 4-1/2ft. JOINT 5/8" DE LA PORTE S15011 DEFLECTEUR • . . -
7 1 CLIP DE VERRE S37002 14 14 14 1).
14 5
8 2 VIS S11086 12 I12
miimr.
9 1 GARANTIE DE CHASSIS(LAITON) S32217
10 1 GARNITURE DE GARDE FEW (LAITON) S32023 12 12 12
11 2 GROUPILLES DE CHARNIERE (S244E/EP) S11005 DISPOSITIONS DES BRIQUES
•
11 2 GROUPILLES DE CHARNIERE (S245E/EP) S11066
12 12 BRIQUES 9" x 4-1/2" S16040
13 2 ECROU A RESSORT S11090
14 4 BRIQUES 7-1/2" x 4-1/2" S16043
15 2 BRIQUES OVADRILATERATE S16042 GARNITURE DECORATIVE EN-LAITON
Apres 1 installation de votre poele a bois, ne manquez
pas d'enlever le revetement protecteur en plastique.
��
, REGLAGE DU VOLET D'ADMISSION D'AIR
111111 .
t Taux de combustion Reglage du volet ""Chaleur d&gag&e
��s
desiree d'admission d'air en BTu (approx.)
POIGNEE A RESSORT Faible Ferme 10,467
Faites tourner Ia poignee a ressort dans le sens Moy. /faible Ouvert 1/4 po 12,336
contraire des aiguilles d'une montre tout-en Moy. / fort Ouvert 1/2 po 17,111
poussant; la poignee a ressort s'enroulera a Ia
Grand Ouvert 24,020
position voulue. **La performance peut varier selon les conditions reelles d'utilisation dans Ia maison.
NOTE:Gardez cette feuille pour consultation futur.
Part No. S19212 Rev. 3 5/94