Loading...
HomeMy WebLinkAboutVarious Code Violations 1987-2001 co 0 .co O l co }, ,. Cl)h U aQ J, LI a? U 0ti .� [T o cn () o � � a� N Vilk071/3-- 3 p (+. .� -o _ o �/ o Udt �s 3 b V O c„ I ! ! O O Cdr cd a) cn OaS � � ""`( awn > 0 a.) 0 E. �. . .d 1- •cd 0 rc 1 N U cd • GQ. 0 > . "11 N gb CI • O Q > ai «i C7 > C ON ¢' r=4Q cct . O 1/l o Q Q cat o O O L7 cd 00 41) V 1.-3 O ~/ Q .9 cn L'44 "'"'ilii • o cn 01 O•N ,J/, 4.4li 7t- E ` NI a U o va °' 3II COH - >, �, o I -n v °) cd -� a� > b U o p N 0O 1 , Z N M C Q Town of Montville Building Department 310 Norwich-New London Tpke. Uncasville, Ct. 06382 8/18/00 Norman Riley 41 Pawcatuck Ave Pawcatuck Ct. 06379 Re: 52 Pequot Rd., Montville, Ct. On August 16, 2000, at approximately 1:00 PM, I was called to the above referenced address by the Fire Marshal. During a fire investigation at that address he found that the unfinished basement was being used as an apartment and he requested that I inspect the building for that and other possible Building Code violations. During my inspection I found the following violations: 1) The unfinished basement is being used as living space. This use is in violation of the State Building Code for a number of reasons including but not limited to the following: a) No bathroom b) No kitchen c) No heat d) No smoke detection e) No separation between living area and storage of hazardous material (gasoline) This use must be discontinued immediately. 2) The buildings front porch has been closed in and converted to living space in each of the four apartments. The rooms created are less than 70 sq. feet in size and therefore are not large enough to be used as habitable space. At least one of these rooms is presently being used as a sleeping room and in addition to the size it does not have an emergency egress or a smoke detector. This use must be discontinued immediately. 3) The porch on the rear of the structure has the following violations: a) 9"to 10" rise on the step leading into each apartment b) Loose metal decking on the upper level due to broken welds c) Uneven risers between treads and on individual treads d) No handrails e) Some treads are are not level(they tilt forward down the stairs) The violations in item three must be addressed within thirty days. Please notify the Building Department in writing of your plan of compliance within 10 days of receipt of this notice. Vernon D. Vesey II Building Official Cc: Fire Marshal Zoning Department File 08/24/00 09:35 FAX 18608877898 t'NCAS HEALTH DIS Z0 law UNCAS HEALTH DISTRICT N2 005152 COMPLAINT Location: 5 &&-' lf3..P Town: , , 7 'i - bate: 2(/‘ ed Tenant: 17//1"-P,/L.P /,004- Phone: a, a— Complainant: —e`t/ r._ Phone: l7 Owner: 1./.0,1109/"L-- 73M4, ---ii� 575Phone: Address: /r. Awl-A-4 rot-, 92 ,P do'ri;ar 463-.7l' / Received by Via: Phone Mail In Person Third Party Complaint: ASSIGNED TO: - - INVESTIGATION: Site Visit: ,, 1 6) Phone: L5 r16' /51 19. 1 /,e5/ `' -�=/A1.9, �.i may, ,c-Z-- -/./- 7- ...e215 ---74.), --i..7 - ..2 v ,7 l,,_ #7;007-; 3o '1 kP /7D, / •4- z %‘-- - iti7 /-214'66 /7 hide-A' 2--- -4- /IMF ! ' .A7/,.- p,P/,/ , ' �e--• r�,c- d'/-- fes! ,„(. 077-p/-c-- ° &',‘ /' FOLLOW-UP Type Date Req'd Date Acc'd By: By: Date Closed: By: TOWN OF MONTVILLE Nue BUILDING INSPECTOR 310 NORWICH-NEW LONDON TPKE. UNCASVILLE, CONNECTICUT 06382 848-7166 12/2/97 TO: Shawn Ryan, Deputy Fire Marshal FROM: Russell H. Stauffer, Building Official RE: Violations at 52 Pequot Road Dear Shawn, The violations on the third floor of the above referenced property were corrected under permit #13814 and a final inspection was done by myself on 11/21/97. Raymond T.Occhialini TOWN OF MONTVILLE TEL:(860)848-1175 Fire Marshal Fire Marshal's Office FAX(860)848.4063 836 Old Colchester Road • Oakdale CT 06370-1637 SECOND NOTICE OF FIRE/LIFE SAFETY HAZARDS Certified Mail- Return Receipt Requested Date: July 1, 1997 To: Mr. Norman Riley 8 Huntington Street Pawcatuck CT 06379 Dear Mr.Riley, On May 27, 1997 this Office sent you a first Notice of Fire/Life Safety Hazards that contained a list of violations found as the result of an inspection conducted of the premises located at 52 Pequot Road, Uncasville,on May 27, 1997,for the purposes of determining compliance with the Connecticut Fire safety Code and applicable standards,adopted pursuant to General Statues, Sections 29-292 and 29-293.The Code and said standards are available for your inspection at the Office. (X) Since this Office has failed to receive any communications from you relative to the First Notice,this Second Notice is being set to you. ( ) As the result of your failure to forfill the agreed upon requirements concerning the modification of an /or extension of time for correction of those violations addressed, this Second Notice is being sent to you. You are hereby ordered to take proper corrective action to remove or remedy all listed violations within fifteen(15)days from the date of your receipt of this Notice,unless otherwise noted on the attached inspection report. The first Notice of Fire/Life Safety Hazards and the attached listed violations is provided again. Your failure to comply with this Notice or to contact this Office within the time period specified constitutes a crime of the General Statues,with penalties of a fine not less than two hundred dollars nor more than one thousand dollars or imprisonment of up to six months,or both,as prescribed in Section 29- 295. Noncompliance may also result in a civil proceeding against you,as authorized in Section 29-306. Respectfully, Shawn P.Ryan SPR:ch Deputy Fire Marshal cc:file I' i i. l a) a) E N t -S -n al o Q V . a) 0CD •C c E > v- (U C U >. ctlo •a N cU cU ,1] m c m E cQ Ti vvoi Eo _> ro HVLn oQ = � cU o a) v; cL naso Z 46 c �° ami o 73 c 0 a� = oc � (U d ca o �c 715 � � s U lfj O N Cn CU () v7. V QCO o CZ 0 .1 o Li c u) c w 0 c ti o O U 0 < 'a Q Lf) ►o _- L- 0 I-- NI U. Q O I-- N I C 0 O V ai a.cri O o O r Q V rn / _ N -� w . r O a) (NI f In. 0 cu 7_ o c > _0 0 F- a� 15 a a. a c (.._ U . 0 o a. i_ cn (U ti 6q, a cn --- a) w O n10 v a) a) a U > C M 0 `O LT — C a ire —v� : it Ii ;i a) ai i aa)) zi .nE a) C c° ; � ; v 7' 7 a) o U E E 0) (,) :.. m c c :. v >, > .� cv p _ N CU n a) U a) E N E � �.N C p co o _ Ct. D !- V 0 0 UQ _c a) V -6 f- Li) L W c0 1- a) 0 t -0 c- O 0 o a c � .3 -;.C'. 7 C N = a) C • ca O to 7 N a) t_ p a) cII 2 > Q (II 0 7 22 "- C p iii p .- v o o3 V O Q •V to vi ‘- < to C O 0 .-C- U No O b > o a) o •O U(L Yy EE a .- I C � � oE aO O o) ......z co co d O rn -- c U 0 g RI p) o rn rt v p F �.+ N c 0 W Ntz. r a) g CO W 0 0 o > F•-- z a I 0 Cr c Q p c to t to >, Cr a) v co a) m E V .a cn -�N ( . (-1 .-- t0 a) U o a) O N r-- tti M 3 a ` o � a) atn oa) o6 (13 (Q Q U. (n . -o tQ Lt_ o n-.-- _C 1 h. ai F- 0 ..C: aii -0 to d CO VVUcn 000 (f) _o .n c ›, ami ami v - O > E. cpv > o 0 c W .-N O. act. TOWN OF MONTVILLE '� Fire Marshal's Office Raymond T. pcchialini 836 OLD COLCHESTER ROAD Fire Marshal OAKDALE, CONNECTICUT 06370-1637 Floyd L. Chaney,Jr. TEL: (860)848-1175 Deputy Fire Marshal FAX(860) 848-4063 May 3, 1996 Mr. Norman Riley • 52 Pequot Road Uncasville CT 06382 RE: ANNUAL FIRE SAFETY INSPECTION Dear Mr. Riley, On May 1, 1996 at a } Ons conductedyof the premises 1300 hours, an inspection was , fortthe premises located at 52 Pequot Road of 5 purposes of determining compliance with the Connecticut fire Safety code and the applicable standards, adopted P pursuant to General Statues, Sections 29-292 and 29- 293. The Code and said standards are available for inspection at this Office. your As a result of this inspection NO violations were cited the Connecticut Fire Safety Code, and we thank you foryou cooperation during-this required inspection. We remindu t that any alterations to Unit 5 must go throughn Department for permits an .Iaperworkhs Building . - , If you should have any questions please feel free to contact the undersigned at the Montville Fire Marshal' s Office. Your next inspection is scheduled for May of 1997 . Respectfully yours, e"--- —A.-- --p 7-s_______ . • SPR:ch Shawn P. Ryan pc: file Deputy Fire Marshal 1 Raymond T.Occhialini TOWN OF MONTVILLE TEL:860 ( )84&1175 Fire Marshal fire MarshAl's Office FAX(860)848-4063 836 Old Colchester Road Oakdale CT 06370-1637 9 June, 1997 Russell Stauffer Building Official 310 Norwich New London Turnpike Uncasville, Connecticut 06382 Ref# 97-64179 Dear Russ, On Tuesday, May 27, 1997, I conducted an annual inspection of the apartment building at 52 Pequot Road, Uncasville. During the inspection, I was made aware that there had been alterations to Apartment 2E and that part of the front stairway had been closed off. The alterations were made within the past year. During a conversation last year, the buildings owner Mr. Norman Riley was advised that any alterations within the structure involving electrical, plumbing or structural modifications would require permits through your Office. I have attempted to set up a meeting with Mr. Riley, yet he has not contacted me since I talked to him earlier this month. I have included a copy of the inspection reports from the last two years. I will still attempt to contact Mr. Riley. If there are any questions or if I can be of any assistance, please feel free to contact me. Respectfully Submitted, Shawn P. Ryan Deputy Fire Marshal TOWN OF MONTVILLE • 9 tc ra ti ac 1 Dfftcc FORT SHANTOK ROAD UNCASVILLE, CONNECTICUT 06382 December 12, 1991 Barbara A. Groupille 62 Summit Street Norwich, CT 06360 RE: Code violation follow-up Inspection Dear Mrs. Groupille ; On 11 December 1991, this Office conducted a follow-up final inspeciton of code violations cited on the Annual Inspection of 29 April 1991. As a result of this inspection, this Office has recognized that all cited violations have been corrected to the satisfaction of the Connecticut Fire Safety Code. Respectfully yours, MEK;ch Michael-4. F',elle Fire Marshal pc:Building Official ReMax Agency Files Nommw TOWN OF MONTVILLE 91tE Anti aL S Dff ez FORT SHANTOK ROAD UNCASVILLE, CONNECTICUT 06362 848- 1175 DATE : 1 October 1991 RE : PLANS REVIEW FOR 52 Pequot Road, Barbara Groupille Dear Sir( s ) ; On 1 October 1991 , this Office completed its review of the plans you submitted for your construction/ renovation project . This Office has =APPROVED your submittals . Q REJECTED COMMENTS : Submittals for Code Upgrade and Compliance, conform to the requirementz per our phone conversation of September 13, 1991. Please remember to include the Hallway AC/DC Smoke Detectors, as they were not mentioned in the submittals. Respectfully yours , 1 rear s a! Town of Montville cc : FMO files Bldg . Inspector CINW TOWN OF MONTVILLE 400 912E SllataIa["1 Off«E FORT SHANTOK ROAD UNCASVILLE, CONNECTICUT 06382 September 11, 1987 Paul Goupile 62 Sumit St. Norwich, CT 06360 RE: Witness Pressure Test on Tank/Piping prior to Covering Mr. Goupille: On September 1, 1987, this office witnessed the pressure test on tank and related piping for the tank located at 52 Pequot Rd. , Uncasville, CT . The test met the required 5 psi. Respectfully yours, kr ifr Michael E. Kelley Fire Marshal MEK:hm cc: Bldg. Inspector Office files TOWN OF MONTVILLE NINO 91tE ciliatlfiars C)f fLeE FORT SHANTOK ROAD UNCASVILLE, CONNECTICUT 06382 July 30, 1987 Paul Goupille 62 Sumit Street Norwich, CT OE360 RE: Criteria for Underground Storage Tank Installation Mr. Goupille: Listed below are the requirements you requested for installation of an underground fuel storage tank to be located at 52 Pequot Rd. , Uncasville, CT. 1. Tank pressure test prior to installation, maximum 5 psi, witnessed by Fire Marshal. 2. Tank to be located minimum of 75 Ft. from wells (Water Supplies) , and no closer than 3 feet near building foundation. 3. Tank shall be set in ground on sand, pea stone or similiar material. This shall be witnessed by Fire Marshal prior tc covering. 4. Prior to total covering of tank, provide a pressure test on tank and piping, maximum 5 psi, witnessed by Fire Marshal. If you have any further questions or comments, please contact the undersigned. Respectfully yours, (41jjk_G-S Michael E. Kelley Fire Marshal MEK:hm cc: Bldg. Department Office Files (1, c7 TOWN OF MONTVILLEp '' • 12.E 4at..I2QLpi. lOf fi.CE FORT SHANTOK ROAD UNCASVILLE, CONNECTICUT 06382 September 11, 1987 Paul Goupille 62 Sumit St. Norwich, CT 06360 RE: Witness Pressure Test on Fuel Storage Tank Mr. Goupille: On August 20, 1987, this office witnessed the pressure test on the tank to be installed at 52 Pequot Rd. , Uncasville, CT. The test met the 5 psi as required. Respectfully yours, (' ) t ' Michael E. Kelley Fire Marshal MEK:hm cc: Bldg. Inspector Office Files