Loading...
HomeMy WebLinkAbout2003 - LP Heating and A/C Town of Montville BUILDING DEPARTMENT 310 Norwich-New London Turnpike Uncasville,CT 06382 (860)848-3030, Ext.382 Mechanical Permit Permit Number: M2003-0061 Date: 27-May-03 Map/Lot: 074/038-000 Owner ID 117507 Job Location: 42 PINK ROW Unit Job Description: Install AC Unit with Propane Heating Section Owner: Contractor: Martin Gottesdiener Titan Mechanical C/O Kostin Ruffkess and Co 150 Batson Drive 400 Bayonet St Ste 306 Manchester Ct. 06040- New London CT 06320 Telephone: (860)645-1617 Lic/Reg Type/No. S1 389112 Exp Date: 31-Aug-03 Tenant: Self Telephone: Construction Values Permit Fees Construction Information Building Value: $0.00 Building Fee: $0.00 Use Group: F-1 Plumbing Value: $0.00 Plumbing Fee: $0.00 Code: 1996 BOCA Mechanical Value: $12,600.00 Mechanical Fee: $76.00 Construction Type: 5B Electrical Value: $0.00 Electrical Fee: $0.00 Permit Code: C5 Other Value: $0.00 Other Fee: $0.00 Comments: Total Value: $12,600.00 CO Fee: $0.00 Plan Review Fee: $0.00 State Ed Fee: $2.02 Total Fees: $78.02 It is the owners responsibility to schedule the following inspections(minimum 48 hours notice required): ❑ Footing-Prior to pouring concrete 0 Rough HVAC ❑ Backfill-Footing drains and waterproofing ❑ Fireplace Throat ❑ Concrete Slab-Prior to pouring concrete ❑ Chimney-One flue above thimble ❑ Rough Framing ❑ Firestopping/draftstopping ❑ Rough Electrical ❑ Insulation ❑ Electrical Service 0 Final Inspection ❑ Rough plumbing and leak test ❑ Certificate of Occupany ❑ Gas piping and test Building Official's Signature: 41, J t Town of Montville 't"' Building Department 310 Norwich-New London Tpke. Permit# �0 � � Tel. 848-3030,Ext 82 Uncasville, CT 06382 Fax. 848-7231 Application for Commercial Trades Permit • F'fum6ing [] fECectricaf A techan" :eating —' Att.Conditioning pots Job Location 7 6 i.,i, _..g jd, 41 7/ Or 4) - Job Description/Materials 4 116/1467,:---- Owner ,'1..., Owner s_ / � y 344. er 0.x'1 Mailing Address EPS /Vent-A- /(../L . //' A_ City L/ll��-44-- h, State (1 Pot) / Nef"/ 92,`7 / Contractor '/���>t,t �/ /l - �eCJ . Mailing Address /5 0 ZI ,-.�S-If'�. .L "? V`€, City 1 1144 l(i 4 ep State f Zip .46lW Tel e10O /6- / /6/ 7 Contractor's License/Registration Type&Number 5-/ 3� / — Exp.Date e? /31i/� 03 I hereby certify that the proposed work will conform to the Basic Building Code and all other codes as adopted by the State of Connecticut and the Town of Montville and further attest that the proposed work is authorized by the owner in fee and that I am authorized to make application for a permit for such work as described above. Owner/Agent Signature ( ....-9 ' Date S / / / (�,.;; Construction Value Fee Building $ $ Plumbing $ $ Mechanical $ `24 $ 7 ' Electrical $ Other $ $ Certificate of Occupancy $ Plan Review Fee State Education $ Total $ l Z r $ .,t.0 Town of 1 "ontville Building Departmc ` Receipt *ofNoof P Date __ / L/__0 No. 02702 From: Job Address: ffr J: -e ,0 Amount $ — t'a1.2 Cash Check Check # 1 / 4 circle one �iL�� Received by 41;,,...,,. ,/; r./...„; .,00",,,,,-5 Permit # / fr • STATE OF CONNECTICUT WORKERS'COMPENSATION COMMISSION Buildin: Permit Affidavit for Pro'e Owners or Sole Pro rietors (Conn. Gen. Stat. §31-286b) Property located at 76 In the town of C /il� Name of building permit applicant ,/ / Please check one: 1. I am the owner of the above property. 2. I am the sole proprietor of a business- • —.Name of business 2B.Federal Employer Identification Number(FEIN .......................... ...........................•-..---...... Pursuant to §31-286b,"a empty owner or sole intends•to act a.. ...n al contractor or principal employer'mayproprietor[who] as a general _. insurance or a"sworn no provide either a certificate of workers'compensation compensation insurance for �those�cmploycdon the job site in accordance proof of workers' ccordance with this chapter." Please check one: 1._I do not intend to act as a general contractor or principal employer. [Sign and stop here] Signature ofapplicant 2. I intend to act as a general contractor ornd i r provide a certificate of workers'compensation �employer.Applicant mast either below. insurance or sign the affidavit Affidavit ... .... ... . I hereby swear.and attest that I will require --.... contractor,subcontractor,or other wrker beforehe/sheh engagesof workers' compensation insurance for every accordance with the Workers'Com in work on the above property in Compensation Act(Chapter 568). I understand that pursuant to§31-275 C.G.S.,officers of a co partnership may elect to be excluded from coverage by filingcorporation and thetapp in a District Office;and that a sole proprietor of a business is nowaiver to haveith appropriate files his intent to accept coverage. required coverage unless he Signature of applicant Subscribed and sworn to before me this day of 200_ (Notary Public!Commissioner of the Superior Court) ,1fi,,,m, Y.„``P, r> '� '/ t,;•4`1k■ ,,,--,1/4, cJ, ,"4 ' ' `.. \i':'''.:1,1',.-� .. 4,1';::T'' 1 h.:•::t4 '41',:-.,":!1.,l,`l vi '�' r n,-,-..'..P3,-..,..'s!. ...-,'C's. 'S�tk , T :. ,Th.,:- o' ;' :.f,L }- ..f,+i. ^efl'$ r ■ .�+ f moi+. t,moi• f,IL.,.'-',,f f Yi}�'i,5. f":,._-,,,f Al "`� 7 + f �' r� 4 -2 , ..+*t *.ti ..,1 N. .ter#"*- -v. -17'rx •sr^'a �-�x.�� sr� .... tee. :. :. 'dy _•a.,�..,:' .�,- '� � '��'e® :.a.,... ' ,an =..�., is i , STATE OF CONNECTICUT + DEPARTMENT OF CONSUMER PROTECTION , r s`.,` F A. i Beit known that f i MARK CONLOGUE {-r 9 y. ICE DR BU4 ‘) CT 06013 i .;F , k•- Y has been certified by the Dap ! ent ? _ ns`umer Protection as a licensed t .-# HEATING, PIPING & , Vii,i� t s r. LIMITED CONTRACTOR [,-y i f ; ' Z I' ; \� ,' ,JS4.-\N; i:Uk it TQANSTV may- I f Effective: 09/01/2002 i k ' x' Expires: 08/31 a"r 2003r,c,,m,,,,rift„,.47 1 ZN%, ' Jam s T.Fleming,Commissioner j "3 t , y 4 aL • ., 4 ,. Jt'' .G,,G)i, •.t 'G;A c W.1P',n Jkd , �+r :r 0 i #',1,1P<:'‘ ,Lil; -.t ,,.`: ' Op•n;tr:.i pc tc.'i' TOWN OF MONTVILLE FIRE MARSHAL'S OFFICE PEWZ.-/0 �h�/E/C 310 NORWICH NEW LONDON iT J UNCASVILLE, CONNECTICUT 0 860-848-1175 A7/-1-k-AN/45.M/c /0A.0,01)/OC t() 41e41,7- SGN Q 5h c0,3T �aES_her -" :";C./ ne et4 .e". Mem, ,,,o ____ ,,„,,c ,,,/,./ Date: 5/5/03 `5',/, _.... .....__ Case # FM02-0595 To: Mr. Vernon Vesey II Building Official 310 Norwich New London Tpke. Uncasville, CT 06382 Subject: Plan Review for T.G. Faria Corp. installation of a HVAC unit Dear Vern, The Town of Montville Fire Marshal's Office received and reviewed plans submitted by Jeffrey Palmer of Titan Mechanical Contractors 150 Batson Drive Manchester CT 860-645-1617. And see no reason not to issue a permit. NOTE: Scheduling of Propane Hookup/Testing to and from building should also go through the Fire Marshals Office. Any items that might have been inadvertently overlooked in the plan review do not relieve the owner from achieving code compliance. A final inspection will be required by the Fire Marshal's Office prior to unit being operated/started. Should you need further assistance or have any questions, please contact the undersigned. Respectfu , 4 Roy(Ed) S afer Fire Inspector cc: file Titan Mechanical Contractors, Inc. 150 Batson Drive Manchester,CT 06040-1694 v:860-645-1105 f:860-645-1176 www.titanmechanical.com April 28, 2003 Re: HVAC Permit To whom it may concern: Jeffrey M. Palmer is authorized by the undersigned as agent of Titan Mechanical Contractors, Inc. to procure the above referenced permit. This permit request is for work to be done at: Thomas G. Faria Corporation 385 Norwich-New London Tnpk. Uncasville, CT 06382-0983 The job is to install one Packaged A.C. Unit with Propane Fired Heating Section. The cost of this work is: Twelve thousand six hundred dollars, ($12,600.00). Attached is a photo-copy of my current Connecticut contractor's license. Signed: Date: y�94,-P Printed Name and Title: Xi/041e C✓®/1)L ppI. = a PPL Corporation company CT License P-1#279991 S-1#303307 certificate is executed by Liberty Mutual Insurance Group as respects such insurance as is afforded by those co .anies. Certificate of Insurance BM0068 This certificate is issued as a matter of information only a ifers no rights afforded by the policies listed below. upon you the certificate holder. This certificate is n isurance policy and does not amend,extend,or alter the coverage This is to certify that(Name and address of Insured) 41111. TITAN MECHANICAL CONTRACTORS rte. 150 BATSON DRIVE fh4 - ; f..,.. , m.._... ...timi... MANCHESTER CT 06040 A is,at the issue date of this certificate,insured by the Company tinder the policy(ies)listed below. The insurance afforded by the listed policy(ies)is subject to all their terms,exclusions and conditions and is not altered by any requirement,term or condition of any contract or other document with respect to which this certificate may be issued. Expiration Type Expiration Date(s) Policy Number(s) Continuous* 12/31!2003 Limits of Liability WA 1-11 D-254244-012 Coverage afforded ander WC law of Employers Liability Extended the following states: X Policy Term Bodily Injury By Accident CT,MA,NY $100,000 Each Accident Bodily Injury By Disease $500,000 Policy Limit Workers Compensation Bodily Injury By Disease $100,000 Each P crsta 12/31/2003 YYI-111-254244-022 General Aggregate-Other than Prod/Completed Operations General Liability $2,000,000 Products/Completed Operations Aggregate Claims Made $2,000,000 X Occurrence Bodily Injury and Property tyDamage Liability 1 Per $1,000,000 Occurrence Retro Date Personal and AdvertisingInjury Jm'Y Per Person/ $1,000,000 Organization Other Liability Other Liability 12/31/2003 AS2-111-254244-042 Each Accident-Single Limit-B.I.and P.D.Combined Automobile Liability $1,000,000 Each Person X Owned X Non-Owned Each Accident or Occurrence X Hired Each Accident or Occurrence C l These policies include Deductible Endorsement with$250,000 deductible limit per occurence for Workers Compensation and$25,000 limit per occurence for General O Liability with the provision that Liberty Mutual will advance payment of the deductible amount. M M E N T S 'If the certificate expiration date is continuous or extended term,you will be notified if coverage is terminated or reduced before the certificate expiration date. However,you will not be notified annually of the continuation of coverage. Special Notice-Ohio:Any person who,with intent to defraud or knowing that he/she is facilitating a fraud against an insurer,submits anapplication or files a claim containinga false or deceptive statement is guilty of insurance fraud. Important information to Florida policyholders and certificate holders:in the event you have any questions or need information about this certificate for any reason,please contact your local sales producer,whose name and telephone number appears in the lower left corner of this certificate. The appropriate local sales office Notice of cancellation: (not mailing address may also be obtained by calling this number. applicable unless a number of days is entered below). Before the stated expiration date the company will not cancel or reduce the insurance afforded under the above policies instil at least 30 days notice of such cancellation has been mailed to: Office: DANVERS,MA Phone: 800-566-0323 f•., r Certificate Holder: Maria G.Abrantes Authorized Representative Date Issued: 04/24/2003 Prepared By: NT TgA /LEz 77z4/LgR.. Tk•tle Ler yex‘ SI 1>e TYR OF(4) E i � E uP Dowist (7. FAR/A Town of Montville Plans Approved for Construction Approval shall not be construed as a permit for,or approval of, any violation of the provisions o the Connecticut Building Cod Copy O File Co' ` J / e3 i NO 3'0ExrEItoFZ c A--"Es g SWAL-4. SLE, ANL /ri eiz,A7'EI) 7V R-7 arZ ReTTEA4 Privra-477o1.1 AiR SHALL I E ,f o o C►-i o SMOKE ;55 e 31/4t,.L 3HurI oWN YS7EM ScovveR., chive ` Pt lv' ACT1(/4J'1oA1 r �Nr sow /� c m r • : 1 DETAILED SYSTEM LOAD REPORT System:System 1 Location:Hartford, Connecticut Block Load 3.05 Prepared by:Aire Tech April 28, Page:ge: 1 1 t TABLE 1.CALCULATION INFORMATION Design Load: July 17:00 Db/Wb Temp 88.8/73.4 F r Winter Design Temo • 3.0 F f TABLE 2.LOAD COMPONENT SUMMARY Design Cooling Loads Design 7 Sensible Latent Heating Load Component Details (BTU/hr) (BTU/hr) (BTU/hr) Solar Loads 0 sqft 0 Wall Transmission 3,380 sqft 5,703 - 23,099 Roof Transmission 3,324 sqft 11,919 - 29,843 Glass Transmission 0 sqft 0 - 0 Skylight Transmission 0 sqft 0 - 0 Partitions 0 sqft 0 - 0 lighting 2.00 W/sqft 22,682 - - - Other Electric 0.00 W/sqft 0 - People 8 People 2,451 3,781 Infiltration 6,932 7,924 33,655 Miscellaneous 0 0 Slab 3,324 sqft - - 23,308 Pulldown/Warm-Up 0 Safety Factor 0/0/0 % 0 0 0 Total Zone Loads 49,688 11,705 109,905 -Ventilation Load 208 CFM 3,095 3,537 1-5,025 Supply Fan Load 2,557 CFM 2,843 - - Plenum Load thru Wall 0 % 0 Plenum Load thru Roof 0 % 0 - Plenum Load-Lights 0 % 0 - - Reheat Load 0 - Total Coil Loads 55.626 14.243 124.930 TABLE 3.WALL AND GLASS BREAKDOWN Total Cooling Cooling Heating i Net Area Transmission Solar Load Transmission Component (sgft) (BTU/hr) (BTU/hr) (BTU/hr) Walls: NE 1,216 1,894 - 8,310 E 0 0 - 0 SE 0 0 - 0 S 1,240 2,265 - 8,474 SW 0 0 - 0 W 924 1,544 - 6,315 NW 0 0 - 0 N 0 0 - 0 Glass: NE 0 0 -- 0 0 E 0 0 0 0 SE 0 0 0 0 S 0 0 0 0 SW 0 0 0 0 W 0 0 0 0 NW 0 0 0 0 N 0 0 0 nor 0 0I 0 0 0 i • a J SYSTEM SIZING SUMMARY System: System 1 Location:Hartford, Connecticut Block Load 3.05 Prepared by:Aire Tech April 28,2003 Page: 1 [TABLE 1.SIZING DATA(COOLING) ` Total Coil Load 70,868 BTU/hr Load Occurs 1 55,626 BTU/hr Sensible Coil Load July 173.4 r Outdoor Db/Wb 88.8/73.4 F Total Zone Sensible 49,688 BTU/hr Coil Conditions: Supply Temperature 57.0 F Entering Db/Wb 77.2/65.6 F Supply Air(Actual) 2,557 CFM Supply Air(Standard) 2,556 CFM Apparatus DewWb 57.0/56.5 F point 55.9 F Ventilation Air 208 CFM Bypass Factor 0.050 Direct Exhaust Air 0 CFM Resulting Zone RH 57. % Reheat Required 0 BTU/hr Total Coil Load 5.91 Ton Floor Area 3,324 sqft Sensible Coil Load 4.64 Ton Overall U-Value 0.118 BTU/hr/sqft/F SQFT/Ton 562.85 Vent Air 0.06 CFM/sqft Cooling 21.32 BTU/hr/sqft Vent Air 25.00 CFM/Person Cooline 0.77 CFM/soft TABLE 2.SIZING DATA(HEATING) Heating Coil Load 124,930 BTU/br Heating 37.58 BTU/hr/sqft Ventilation Load 15,025 BTU/br Heating 0.77 CFM/sqft Total Zone Load 109,905 BTU/hr Floor Area 3,324 sqft Ventilation Airflow 208 CFM Overall U-Value 0.118 Supply Airflow 2,557 CFM Vent Air 0.06 CFM/sqft Vent Air 25.00 CFM/Person [TABLE 3.INPUT DATA(WEATHER) ` Location Hartford,Connecticut t Data Source User Defined Summer Dry-Bulb 91.0 F Latitude 41.7 Degree Coincident Wet-Bulb 74.0 F Elevation 15.0 ft Daily Range 22.0 F Atmosuheric Clearness# 1.00 Winter Drv-Bnlh- 3.0 F TABLE 4. INPUT(HVAC SYSTEM) -,i System Name System 1 THERMOSTAT SETPOINTS System Type Clg and Warm Air Ht Cooling(Occ.) 75.0 F System Start 6:00 Cooling(Unoce.) 75.0 F Duration 24 hrs Heating 70.0 F SIZING SPECIFICATIONS RETURN AIR PLENUM No Supply 57.0 F FAN Ventilation 25.00 CFM/person Configuration Blow-Thru Exhaust 0.00 CFM Static Pressure FACTORS 1.50 in.wg. Coil Bypass 0.050 Safety(Sens) 0 Safety(Latent) 0 Heating Safety 0 r [TABLE 5. TOP TEN COOLING COIL LOADS Time Sensible Ton Total Ton Time Sensible Ton Total Ton 1) July 17:00 4.64 5.91 6) August 16:00 4.53 5.80 2) July 16:00 4.63 5.90 7) August 15:00 4.45 5.71 3) July 15:00 4.56 5.82 8) August 18:00 4.45 5.71 4) July 18:00 4.55 5.82 9) July 19:00 4.40 5.66 5) August 17:00 4.53 5.80 10) July 14:00 4.39 5.64 it a,. • + SYSTEM SIZING SUMMARY System:System 1 Location:Hartford, Connecticut Block Load 3.05 April 28,2003 Prepared by:Aire Tech Page:2 [TABLE 6. ZONE SIZING DATA Max.Cooling Design Airflow Max.Heating Design Flow Sensible Rate Load Rate Zone Name (BTU/hr) (CFM) Design Time (BTU/hr) (CFM) Loading Dock 49,688 2,557 July 17:00 109,905 - Total: 2,557 Total: .00 w 1 I. 036-21058-003-A-1102 421YORK® DESCRIPTION Heating and Air Conditioning YORK®Predator units are convertible single packages with a common footprint cabinet and common roof curb for all 6-1/2 through 12-1/2 ton models.All units have two compressors with independent refrigeration circuits to pro- TECHNICA L vide two stages of cooling. The units were designed for commercial applications and can be easily installed on a roof curb,slab,or frame. GUIDEAll Predator."" units are self-contained and assembled on rigid full perimeter base rails allowing for 3-way forklift access and overhead rigging.Every unit is completely rA p PLCM Tii(j1 P TM charged,wired, piped,and tested at the factory to provide a quick and easy field installation. All units are convertible between side and down airflow. A independent economizer design is used on side and down discharge applications, as well as all tonnage sizes. STANDARD EFFICIENCY Predator-T'" units are available in the following configura- tions:cooling only, cooling with electric heat, and cooling SINGLE PACKAGE AIR CONDITIONERS AND with gas heat. Electric heaters are available only as field- installed accessories. SINGLE PACKAGE GAS/ELECTRIC UNITS DM 078, 090, 102, 120, 150 6-1/2, 7-1/2, 8-1/2, 10, 12-1/2 NOMINAL TONS 9.0 EER te MYORK 7F i. Tested in accordance with: L ' _ _ DESIGN 1 s• ell4 rt OW CEN TIFIEO L p1.c,CD TO 4,44., � P C 94, � . E / 2. • t(P)Iir FTIF t�'ST4NWP0 FOR DISTRIBUTION USE ONLY-NOT TO BE USED AT POINT OF RETAIL SALE 036-21058-003-A-1102 TABLE OF CONTENTS DESCRIPTION 1 LIST OF TABLES FEATURES 3 Tbl. # Pg. # FACTORY INSTALLED OPTIONS 5 1 ACCESSORIES 7 FIELD INSTALLED ACCESSORIES 6 2 PRODUCT NOMENCLATURE 8 GUIDE SPECIFICATIONS 40 3 AIRFLOW ABBREVIATIONS 9 4 INSTALLATION ABBREVIATIONS 9 LIST OF FIGURES 5 ADDITIONAL OPTIONS ABBREVIATIONS 9 Fig. # Pg. # 6 PHYSICAL DATA 10 1 PREDATORY" COMPONENT LOCATION 3 7 STANDARD EFFICIENCY DM MODELS 11 2 UNIT 4 POINT LOAD 33 8 UNIT VOLTAGE LIMITATIONS 11 3 UNIT CENTER OF GRAVITY 33 9 COOLING CAPACITY 6-1/2 TON UNIT 12 4 UNIT 6 POINT LOAD 33 10 COOLING CAPACITY 7-1/2 TON UNIT 13 11 COOLING CAPACITY 8-1/2 TON UNIT 14 5 UNIT DIMENSIONS 34 12 COOLING CAPACITY 10 TON UNIT 15 6 PREDATORY" ROOF CURB DIMENSIONS . . 35 13 COOLING CAPACITY 12-1/2 TON UNIT 16 7 SUNLINETM TO PREDATORY" TRANSITION 14 ELECTRICAL DATA 6-1/2 TON-STD. EFF 17 ROOF CURBS 35 15 ELECTRICAL DATA 7-1/2 TON-STD. EFF 18 8 BOTTOM DUCT OPENINGS (FROM ABOVE) 36 16 ELECTRICAL DATA 8-1/2 TON-STD. EFF 19 9 REAR DUCT DIMENSIONS 36 17 ELECTRICAL DATA 10 TON-STD. EFF. 20 10 COOLING UNIT WITH GAS HEAT WIRING 230 18 ELECTRICAL DATA 12-1/2 TON-STD. EFF 21 VOLT DIAGRAM 37 19 ELECTRIC HEAT MULTIPLIERS 21 11 COOLING UNIT WITH/WITHOUT ELECTRIC 20 BLOWER PERF 6-1/2 TON SIDE DUCT 22 HEAT WIRING DIAGRAM 38 21 BLOWER PERF 7-1/2 TON SIDE DUCT 23 12 COOLING UNIT WITH GAS HEAT WIRING 460, 22 BLOWER PERF 8-1/2 TON SIDE DUCT 24 575 VOLT AND 50 HZ DIAGRAM 39 23 BLOWER PERF 10 TON SIDE DUCT 25 24 BLOWER PERF 12-1/2 TON SIDE DUCT 26 25 BLOWER PERF 6-1/2 TON DOWNSHOT 27 26 BLOWER PERF 7-1/2 TON DOWNSHOT 28 27 BLOWER PERF 8-1/2 TON DOWNSHOT 29 28 BLOWER PERF 10 TON DOWNSHOT 30 29 BLOWER PERF 12-1/2 TON DOWNSHOT 31 30 ADDITIONAL STATIC RESISTANCE 32 31 INDOOR BLOWER SPECIFICATIONS 32 32 4 POINT LOAD WEIGHT 33 33 6 POINT LOAD WEIGHT 33 34 UNIT WEIGHT 33 35 UNIT CLEARANCES 34 2 Unitary Products 036-21058-003-A-1102 "Simplicity"Control Board w/ Terminal Block Screw Connector for T-stat Disconnect Location Filter Access S for Hi-Voltage Wiring and Network Filter-Drier olid Core Connection Connection (Optional Disconnect Switch) (2"Filters) ( ) Condenser Section -AO/Second model nameplate inside • hinged access panel Belt-Drive Blower Motor Dual stage cooling for lEe:t0r ='-:'''Alb easy adjustment Compressor 1 and service. #2 Access r r(High-Eff I 'k �/CtCompressor w/crankcase , -t aheater) Base Rails w/Forklift - Power Ventor Motor Slots(3 Sides)&Lifting Holes ---------hi. heat- RoofIs/\ curbs in eight-and ` r Two-stage gas fourteen-inch heights. \ ol°' ing warm,to comfort Slide-Out Drain comfortable Rood curbs for transi- Pan w/Steel 3/4" tioning from York Sun- ,� temperature line footprint to the DM Tool-less FPT Connection Series footprint are also door latch Side entry power Intelligent control board for and control wiring C mpressor#1 Access(High-Eff available(field-installed knockouts Compressor w/crankcase heater) safe and efficient operation accessory) FIGURE 1 : PREDATORTM COMPONENT LOCATION FEATURES Service windows have been placed in both condenser • Standard Efficiency—All standard efficiency units have section walls. Rotation of the cover allows easy access a minimum EER of 9.0. Gas/electric units have elec— tronic spark ignition and power vented combustion with Both the unit control board and ignition control board uti- steady state efficiencies of 80%. lize flash codes to aid in diagnosis of unit malfunctions. • Service Friendly—The Predator" incorporates a num- Unique alarm codes quickly identify the source of the ber of enhancements which improve serviceability. unit alarm. All units use the same standard filter size. This stan- The motor and blower slide out of the unit as a common assembly. This facilitates greater access to all the indoor dardization removes any confusion on which filter sizes airflow components, thus simplifying if maintenance and are needed for replacement. 9 adjustment. The non-corrosive drain pan slides out of the unit to per- ing Service time is reduced through the use of hinged, tool- mit easy cleaning. The drain pan is accessed by remov- less panels. Such panels provide access to frequently On the drain pan cover plate on the rear of the unit. inspected components and areas, including the control Once the plate is removed, the drain pan slides out box, compressors,filters, indoor motor&blower, and the through the rear of the unit. heating section. The panels are screwed in place at the All PredatorTm units have a second model nameplate factory to prevent access by children or other unautho- located inside the control access door. This is to prevent rized persons. It is recommended that the panels be deterioration of the nameplate through weathering. secured with screws once service is complete. Unitary Products 3 • 036-21058-003-A-1102 • Environmentally Aware — For improved Indoor Air • Nuisance Trip Protection and Strikes-To prevent Quality, foil faced insulation is used exclusively through- nuisance trouble calls, the control board uses a out the units. "three times, you're out" philosophy. The high and • Balanced Heating — The PredatorTm offers "Ultimate low-pressure switches and the freezestats must trip three times within two hours before the unit control Heating Comfort" with a balance between 1st and 2nd board will lock out the associated compressor. stage gas heating. The 1st stage of a gas heat Preda- tor" unit provides 60% of the heating capacity. Bal- • On Board Diagnostics-Each alarm will energize a anced heating allows the unit to better maintain desired trouble light on the thermostat, if so equipped, and temperatures. flash an alarm code on the control board LED. Each • high and low-pressure switch alarm as well as each Convertible Airflow Design —The side duct openings freezestat alarm has its own flash code. The control are covered when they leave the factory. If a side sup- board saves the five most recent alarms in memory, ply/return is desired,the installer simply removes the two and these alarms can be reviewed at any time. side duct covers from the outside of the unit and installs Alarms and programmed values are retained them over the down shot openings. No panel cutting is through the loss of power. required. Convertible airflow design allows maximum field flexibility and minimum inventory. • Reliable—From the beginning—All units undergo com- puter automated testing before they leave the factory. • System Protection — Suction line freezestats are sup- Units are tested for refrigerant charge and pressure, unit plied on all units to protect against loss of charge and coil amperage, and 100% functionality. For the long term — frosting when the economizer operates at low outdoor air All PredatorTM units are painted with a long lasting, pow- temperatures while the compressors are running. Every der paint that stands up over the life of the unit.The paint unit has solid-core liquid line filter-driers and high and used has been proven by a 750 hour salt spray test. low-pressure switches. Internal compressor protection is • standard on all compressors. Crankcase heaters are Flexible Placement — All models and configurations share the same cabinet/footprint and thus the same roof standard on reciprocating compressors. Scroll compres sors do not require crankcase heaters. curb. You have the flexibility to set one curb and choose the correct tonnage size and heating option after the • Advanced Controls - PredatorT" control boards have internal loads have been determined. standardized a number of features previously available To further simplify planning and installation, Predator."'as options or by utilizing additional controls. cabinets are designed to fit your roof. With the optional • Low Ambient - An integrated low-ambient control roof curb, the unit ductwork is designed to fit around 24" allows all units to operate in the cooling mode down on-center joists or between 48"on-center joists. to 0°F outdoor ambient without additional assis- The drain pan can be rotated to drain to either the front tance. Optionally, the control board can be pro- or the rear of the unit. Additionally, the drain pan can be grammed to lockout the compressors when the Piped to drain through the roof curb. As it is sometimes outdoor air temperature is low or when free cooling is available. difficult to have a level installation,the drain pan features a generous slope to ensure proper drainage. • Anti-Short Cycle Protection - To aid compressor life, an anti-short cycle delay is incorporated into the • Full Perimeter Base Rails—The permanently attached base rails provide a solid foundation for the entire unit standard controls. Compressor reliability is further and protect the unit during shipment. The rails offer fork- ensured by programmable minimum run times. For lift access from 3 sides, and rigging holes are available testing,the anti-short cycle delay can be temporarily overridden with the push of a button. so that an overhead crane can be used to place the units on a roof. • Fan Delays-Fan on and fan off delays are fully pro- • Easy Installation—Gas and electric utility knockouts are grammable. Furthermore, the heating and cooling supplied in the unit underside as well as the side of the fan delay times are independent of one another. All unit. A clearly identified location is provided to mount a units are programmed with default values based field supplied electrical disconnect switch. Utility con- upon their configuration of cooling and heat. nections can be made quickly and with a minimum • Safety Monitoring-The control board monitors the amount of field labor. high and low-pressure switches,the freezestats,the gas valve, if applicable, and the temperature limit All units are shipped with 2"filters installed. switch on gas and electric heat units. The unit con- Wide Range of Indoor Airflows—All indoor fan motors trol board will alarm on ignition failures, compressor are belt-drive type providing maximum flexibility to han- lockouts and repeated limit switch trips. dle most airflow requirements. For high static applica- tions, factory installed alternate indoor fan motors are 4 Unitary Products 036-21058-003-A-1102 available. With the optional indoor fan motor, all units the two enthalpy or temperature inputs and positions the can supply nominal airflow at a minimum of 1.5" ESP. dampers to provide the maximum efficiency possible. • Warranty -All models include a 1-year limited warranty • Sideflow Economizer- (Without barometric relief) -All on the complete unit. Compressors and electric heater features as the downflow economizer exist except you elements each carry a 5-year warranty. Aluminized steel must order the barometric relief separately. You must and stainless steel tubular heat exchangers carry a addi- order a 1 EH0408 if you are installing a power tional 10-year warranty. exhaust. You can order a 1 RD0411 barometric relief for sideflow economizer only. FACTORY INSTALLED OPTIONS • Motorized Outdoor Air Damper - The motorized out- YORK®offers several equipment options/accessories factory door air damper includes a slide-in/plug-in damper installed,for the Predator"'line. assembly with an outdoor air hood and filters. The out- door air dampers open to the preset position when the • Alternate Indoor Blower Motor- For applications with indoor fan motor is energized. The damper has a range of 0%to 100%outdoor air entry. Factory installed option high restrictions, units are offered with optional indoor motors that provide higher static output and/or higher air or field installed accessory. flow,depending upon the installer's needs. • Power Exhaust (Downflow only) - This accessory • Coil Guard-Customers can purchase a coil guard kit to installs in the unit with a down flow economizer. Power exhaust plugs into the connector in the unit bulkhead. protect the condenser coil from damage. Additionally, this kit stops animals and foreign objects from entering • Phase Monitors - Designed to prevent unit damage. the space between the inner condenser coil and the The phase monitor will shut the unit down in an out-of- main cabinet.This is not a hail guard kit. phase condition. (Standard on units with Scroll Compres- • Convenience Outlet - (Non-Powered) - This option sors.) locates a 120V GFCI single-phase outlet with cover on • Smoke Detectors-The smoke detectors stop operation the corner of the unit housing the compressors. The of the unit by interrupting power to the control board if installer must provide the 120V single-phase power smoke is detected within the air compartment. source and wiring. Factory installed option only. • Stainless Steel Heat Exchanger - For applications in • Dirty Filter Switch -This kit includes a differential pres- corrosive environments, this option provides a full stain- sure switch that energizes the fault light on the unit ther- less steel heat exchanger assembly. mostat, indicating that there is an abnormally high pressure drop across the filters. Factory installed option • Technicoat Condenser Coils-The condenser coils are or field installed accessory. coated with a phenolic coating for protection against cor- rosion due to harsh environments. • Disconnect Switch - For gas heat units, a HACR breaker sized to the unit is provided. For cooling units • Technicoat Evaporator Coil - The evaporator coil is with electric heat, a switch sized to the largest electric coated with a phenolic coating for protection against heat available for the particular unit is provided. Factory harsh environments. installed option only. • Novar® BAS Control - The Novar® ETC-3 building • Downflow Economizer - (With barometric relief) - The automation system controller is factory installed. Incudes economizer is provided with a single enthalpy input. The supply air sensor, return air sensor, dirty filter indicator economizer is 2% low leakage type. The economizers switch, and air proving switch. are shipped installed and wired. The installer needs only • Johnson Controls BAS Control-The Johnson Control assemble and mount the outdoor air hood. The econo- YK-UNT-1126 building automation system controller is mizer has spring return, fully modulating damper actua factory installed. Includes supply air sensor, return air tors and is capable of introducing up to 100%outdoor air. As the outdoor air intake dampers open, the return air sensor,dirty filter indicator switch,and air proving switch. dampers close. The changeover from mechanical refrig- • CPC BAS Control - The Computer Process Controls eration to economizer operation is regulated by the stan- Model 810-3060 ARTC Advanced Rooftop building auto- dard single enthalpy input. There is an optional input mation system controller is factory installed. Includes dual dry bulb available.To meet regulated air standards, supply air sensor, return air sensor, dirty filter indicator the economizer control accepts an optional CO2 input for switch, and air proving switch. demand ventilation. • Honeywell BAS Control - The Honeywell W7750C With single enthalpy input,the economizer control moni- building automation system controller is factory installed. tors outdoor air.The dual enthalpy kit provides a second Includes air supply sensor, return air sensor, dirty filter input used to monitor the return air. With a dual input kit indicator switch, and air proving switch. installed, the economizer control compares the values of Unitary Products 5 036-21058-003-A-1102 • BAS Ready Economizer- The economizer is provided are included with the heaters. All heaters are intended with a Belimo actuator that requires a 0-10V DC input for single point power supply. from an external source(i.e.,field installed building auto- • Flue Exhaust Extension Kit- In locations with wind or mation system controller). Barometric relief or power exhaust options are available.The economizer is 2%low weather conditions which may interfere with proper exhausting of furnace combustion products, this kit can leakage type with spring return and fully modulating dampers capable of introducing up to 100% outside air. be installed to prevent the flue exhaust from entering Also include 2"pleated filters. nearby fresh air intakes. • Gas Heat High Altitude Kit — This kit converts a gas FIELD INSTALLED ACCESSORIES heat unit to operate at high altitudes,2,000 to 6,000 feet. YORK®offers several equipment options/accessories for field Conversion kits are available for natural gas and pro- installation,for the Predator'"Magnum line. pane. • Gas Heat Propane Conversion Kit-This kit converts a • -60°F Gas Heat Kit- For installations which require gas heat units to perform in low ambient temperatures, a gas gas-fired heater from natural gas to propane. It contains the main burner orifices and gas valve replacement section heating kit is available. This kit provides electric heat in the gas heat controls section to ensure the gas springs. valve and controls will continue to function properly at • Hail Guard - This kit includes a sloped hood which extremely low temperatures. installs over the outside condenser coil and prevents damage to the coil fins from hail strikes. Field installed • Barometric Relief- Zero to 100% capacity barometric relief damper for use with sideflow economizer. accessory only. • Manual Outdoor Air Damper - Like the motorized out- • Burglar Bars-Mount in the supply and return openings door air damper, each manual outdoor air damper to prevent entry into the duct work. includes a slide-in damper assembly with an outdoor air • CO2 Sensor - Senses CO2 levels and automatically hood and filters. Customers have a choice of dampers overrides the economizer when levels rise above the with ranges of 0% to 100% or 0% to 35% outdoor air preset limits. entry. • • Coil Guard-Field installed decorative wire coil guard. Power Exhaust-This accessory installs in the unit with a down flow economizer. Power exhaust plugs into the • Dirty Filter Switch -This kit includes a differential pres- connector in the unit bulkhead. You must purchase sure switch that energizes the fault light on the unit ther- 1 EH0408 barometric relief/power exhaust hood when mostat, indicating that there is an abnormally high applying to a sideflow application. pressure drop across the filters. • Roof Curbs - The roof curbs have insulated decks and • Enthalpy Accessory Control Kit-This kit contains the are shipped disassembled The roof curbs are available required components to convert a single enthalpy econo- in 8"and 14"heights. mizer to dual enthalpy. For applications with security concerns, burglar bars are • Economizer (Downflow with barometric relief) - Econo- available for the duct openings of the roof curbs. mizer with relief damper and single enthalpy input (2% low leakage damper). • Roof Curb Adaptor Single Piece Adapter (10" High) - Roof curbs for transitioning from SunlineTM units to Pred- Spring return fully modulating motor capable of introduc- atorT"' Magnum. Fits 7.5 to 12.5 SunlineT"" roof curbs ing up to 100% outside air. For power exhaust, add the only. power exhaust accessory. • Smoke Detectors-The smoke detectors stop operation • Economizer (Horizontal) - Horizontal economizers are of the unit by interrupting power to the control board if designed to install in the lower return section on the side smoke is detected within the air compartment. of the unit. It is specifically designed for horizontal return • Thermostat-The units are designed to operate with 24- applications. 1 EH0408 barometric relief/power volt electronic and electro-mechanical thermostats. All exhaust hood must be purchased separately. You units (with or without an economizer) operate with two may also order a 1RD0411 barometric relief if a stage heat/two-stage cool or two-stage cooling only ther- power exhaust isn't being installed. The horizontal economizer is available with standard single enthalpy mostats, depending upon unit configuration. control. Dual enthalpy may be added by installing the • Motorized Outdoor Air Damper - The motorized out- dual enthalpy kit. door air damper includes a slide-in/plug-in p g-in damper • Electric Heaters - The electric heaters range from 18 assembly with an outdoor air hood and filters. The out- kW to 54kW and are available in all the voltage options door air dampers open to the preset position when the of the base units. All heaters are dual staged. Cooling indoor fan motor is energized. The damper has a range units include an adapter panel for easy installation of the of 0%to 100%outdoor air entry. Factory installed option electric heaters. Necessary hardware and connectors or field installed accessory. 6 Unitary Products SELECTED E.u I P t o N l i!- -1)A4-1)A4o 036-21058-003-A-1102 io 0 15D N iA aA DM120N15A2AAA3 TABLE 2: PRODUCT NOMENCLATURE Model Model Number # Description Options D Product Category D=Air Conditioner,Single Package M Product Identifier M=Standard Efficiency 120 Nominal Cooling 078=6-1/2 Ton 102=8-1/2 Ton Capacity MBH 090=7-1/2 Ton 120=10 Ton 150=12-1/2 Ton N Heat Type C=Cooling Only N=Natural Gas,Aluminized Steel S=Natural Gas,Stainless Steel 15 Nominal Heating 00=No Heat Installed Capacity 10=100 MBH Output Gas Heat 15=150 MBH Output Gas Heat 20=200 MBH Output Gas Heat A=SM B=SMNEC/BR Q=High Static MotorNEC/PE M=SM/BAS VEC/PE/2"Pleated C=SMNEC/PE R=High Static Motor/MD Filters (Downflow only) Y=High Static Motor/BAS A Airflow D=SM/MD(Downflow only) E=SM/Horiz EC S=High Static Motor/Horiz EC VECBR/2"Pleated Filters N=High Static Motor L=SM/BAS VEC/BR/2"Pleated Z=High Static Motor/BAS P=High Static MotorNEC/BR Filters VEC/PE/2"Pleated Filters 2 Voltage 2=208/230-3-60 4=460-3-60 5=575-3-60 A=None G=1 &3 N=2&3 B= 1 H=1 &4 P=2&4 A Installation C=2 J=1,2&3 Q=2,3&4 Options D=1 &2 K=1,2&4 R=3&4 • E=3 L=1,3&4 F=4 M=1,2,3&4 M=None JH=JC,DFS,APS,TCC,PM&CG NH=NC,DFS,APS TCC,PM&CG AB=PM JJ=JC,DFS,APS&TEC NJ=NC,DFS,APS&TEC AC=CG JK=JC,DFS,APS,TEC&PM NK=NC,DFS,APS,TEC&PM AD=DFS JL=JC,DFS,APS,TEC&CG NL=NC,DFS,APS,TEC&CG AE=PM&CG JM=JC,DFS,APS,TEC,PM&CG NM=NC,DFS,APS,TEC,PM&CG AF=PM&DFS JN=JC,DFS,APS,TEC&TCC NN=NC,DFS,APS,TEC&TCC AG=CG&DFS JP=JC,DFS,APS,TEC,TCC&PM NP=NC,DFS,APS,TEC,TCC&PM AH=PM,CG&DFS JQ=JC,DFS,APS,TEC,TCC&CG NQ=NC,DFS,APS,TEC,TCC&CG CA=CC,DFS&APS JR=JC,DFS,APS,TEC,TCC,PM NR= NC, DFS,APS, TEC, TCC, PM CB=CC,DFS,APS&PM &CG &CG CC=CC,DFS,APS&CG HA=HC,DFS&APS TA=TCC CD=CC,DFS,APS,PM&CG HB=HC,DFS,APS&PM TB=TCC&PM CE=CC,DFS,APS,TCC HC=HC,DFS,APS,&CG TC=TCC&CG CF=CC,DFS,APS,TCC&PM HD=HC,DFS,APS,PM&CG TD=TCC&DFS CG=CC,DFS,APS,TCC&CG HE=HC,DFS,APS&TCC TE=TCC,PM&CG CH=CC,DFS,APS,TCC,PM&CG HF=HC,DFS,APS,TCC&PM TF=TCC,PM&DFS AA Additional Options CJ=CC,DFS,APS&TEC HG=HC,DFS,APS,TCC&CG TG=TCC,CG&DFS CK =CC,DFS,APS,TEC&PM HH=HC,DFS,APS,TCC,PM&CG TH=TCC,PM,CG&DFS CL=CC,DFS,APS,TEC&CG HJ=JC,DFS,APS&TEC TJ=TEC CM=CC,DFS,APS,TEC,PM&CG HK=HC,DFS,APS,TEC&PM TK=TEC&PM CN=CC,DFS,APS,TEC&TCC HL=HC,DFS,APS,TEC&CG TL=TEC&CG CP=CC,DFS,APS,TEC,TCC&PM HM=HC,DFS,APS,TEC,PM&CG TM=TEC&DFS CQ=CC,DFS,APS,TEC,TCC&CG HN=HC,DFS,APS&TEC TN=TEC,PM&CG CR=CC,DFS,APS,TEC,TCC,PM HP=HC,DFS,APS,TEC,TCC&PM TP=TEC,PM&DFS &CG HQ=HC,DFS,APS,TEC,TCC&CG TQ=TEC,CG&DFS CV=CC,DFS,APS&2"PF HR=HC,DFS,APS,TEC,TCC,PM TR=TEC,PM,CG&DFS CX=CC,DFS,APS,2"PF&TCC &CG TS=TEC&TCC JA=JC,DFS&APS NA=NC,DFS&APS TT=TEC,TCC&PM JB=JC,DFS,APS&PM NB=NC,DFS,APS&PM TU=TEC,TCC&CG JC=JC,DFS,APS&CG NC=NC,DFS,APS&CG TV=TEC,TCC&DFS JD=JC,DFS,APS,PM&CG ND=NC,DFS,APS,PM&CG TW=TEC,TCC,PM&CG JE=JC,DFS,APS&TCC NE=NC,DFS,APS&TEC TX=TEC,TCC,PM&DFS JF=JC,DFS,APS,TCC&PM NF=NC,DFS,APS,TCC&PM TY=TEC,TCC,CG&DFS JG=JC,DFS,APS,TCC&CG NG=NC,DFS,APS,TCC&CG TZ=TEC,TCC,PM,CG&DFS 3 Product Generation 3=Third Generation 8 Unitary Products 036-21058-003-A-1102 TABLE 3: AIRFLOW ABBREVIATIONS TABLE 5: ADDITIONAL OPTIONS ABBREVIATIONS ABBREVIATION MEANING ABBREVIATION MEANING BR Barometric Relief APS Air Proving Switch EC Economizer CC CPC Controller VEC Vertical Economizer CG Coil Guard MD Motorized Damper DFS Dirty Filter Switch PE Power Exhaust HC Honeywell Controller SM Standard Motor JC Johnson Controls Controller BAS Building Automation System NC Novar Controller TCC Technicoat Condenser Coil TEC Technicoat Evaporator Coil TABLE 4: INSTALLATION ABBREVIATIONS ABBREVIATION MEANING 1 Disconnect 2 Convenience Outlet 3 Smoke Detector Supply Air 4 Smoke Detector Return Air Unitary Products 9 036-21058-003-A-1102 • TABLE 6: PHYSICAL DATA Models Component 078 090 102 120 150 Blower,Centrifugal(Dia.X Wd.in.) 15 x 15 15 x 15 15 x 15 15 x 15 15 x 15 Evaporator Blower Motor,Standard(HP) 1-1/2 1-1/2 2 2 3 Motor,Optional(HP) 2 2 3 3 5 Rows 2 2 3 2 3 Evaporator Fins per Inch 15 15 15 15 15 Coil Height(in.) 30 32 24 40 40 Face Area(ft.2 each) 9.9 10.6 7.9 13.2 13.2 Condenser Propeller Dia.(in.,each) 24 24 24 24 24 Fan Motor(HP,each) 1/3 1/3 3/4 3/4 3/4 (2 per Unit) CFM,Nominal(each) 3400 3400 4400 4400 4400 Rows(each) 1 1 1 1 2 Condenser Fins per Inch 20 20 20 20 20 Coil (2 per unit) Height(in.each) 24 28 36 44 44 Face Area(ft.2 each) 7.9 9.2 11.9 14.5 14.5 Refrigerant System 1 (Ib./oz.) 4/6 4/12 5/0 6/12 10/12 Charge System 2(Ib./oz.) 4/0 4/6 5/4 6/12 9/8 Quantity 2 2 2 2 2 Compressors Type Recip Recip Recip Recip Recip Size(Wd.x Ht.x Thickness in.) 25x20x2 25x20x2 25x20x2 25x20x2 25x20x2 Air Filters Number Per Unit 4 4 4 4 4 10 Unitary Products 036-21058-003-A-1102 TABLE 7: STANDARD EFFICIENCY DM MODELS Cooling Capacities ARI Ratings* Sound Nominal Gas Heat Capacity Size Model Electric Heat Gas Line ze (Tons) CFM Rating MBH EER IPLV (dB)t Capacityt Input Output Seasonal Temp. in.StOD (kW) Efficiency Rise ( ) (MBH) (MBH) (%) (°F) Cooling Only - (078) Electric 6-1/2 Heat 77 9.0 9.45 2600 84 9,18,24,34 - - - - - Gas Heat - 120 96 80 20-50 3/4 Gas Heat - 180 144 80 35-65 3/4 Cooling Only (090) Electric 7-1/2 Heat 86 9.0 10.15 3000 84 9.18,24,34 Gas Heat - 120 96 80 15-45 3/4 Gas Heat - 180 144 80 30-60 3/4 Cooling Only - - (104) Electric 8412 Heat 98 9.0 3000 9,18,24,34 - - - t Gas Heal - 120 96 80 15-45 3/4 Gas Heat - 180 144 80 10-40 3/4 Cooling Only Z (120) Electric 10 Heat 120 9.0 9.10 4000 90 9,24,34 54 - - - - - Gas Heat - 180 144 80 20-50 3/4 Gas Heat - 240 192 80 35-65 3/4 Cooling Only - - - - (150) Electric 12-1/2 Heat 140 9.0 9.25 4500 90 9,24, . i? Gas Heat - 180 144 80 10-40 3/4 Gas Heat - 240 192 80 25-55 3/4 " Rated at 95°F ambient 80°F dry bulb and 67°F wet bulb. t Rated in accordance with ARI 270 standard. $ See Table 19. ; TABLE 8: UNIT VOLTAGE LIMITATIONS POWER RATING MIN. MAX. 208/230-3-60 187 252 460-3-60 432 504 575-3-60 540 630 k {: f Unitary Products 11 036-21058-003-A-1102 TABLE 15: ELECTRICAL DATA 7-1/2 TON-STANDARD EFFICIENCY OD Supply Blower Pwr Exh Min.Circuit MCA Max Fuse Size Model Compressors Fan Ampacity wlPower Max Fuse wlPower Motors Motor FLA Motor Electric Heater Actual Heater (Amps) Exhaust Size(Amps) Exhaust Model No. kW Amps (Amps) (Amps) Voltage RLA LRA FLA 1.5 HP 2 HP FLA 1.5 2 1.5 2 1.5 2 1.5 2 ea. ea. ea. HP HP HP HP HP HP HP HP None - - 39.6 41.6 45.1 47.1 50 50 50 60 2TP04510925 6.8 18.9 39.6 41.6 45.1 47.1 50 50 50 60 208 13.5 130 1.5 6.2 8.2 5.5 2TP04511825 13.5 37.5 54.6 57.1 61.5 64.0 60 60 70 70 2TP04512425 18.0 50.0 70.2 72.7 77.1 79.6 80 80 80 80 2TP04513625 25.5 70.8 96.2 98.7 103.1 105.6 100 100 110 110 None - - 39.6 41.6 45.1 47.1 50 50 50 60 2TP04510925 9.0 21.7 39.6 41.6 45.1 47.1 50 50 50 60 230 13.5 130 1.5 6.2 8.2 5.5 2TP04511825 18.0 43.3 61.9 64,4 68.8 71.3 70 70 70 80 2TP04512425 24.0 57.7 79.9 82.4 86.8 89.3 80 90 90 90 2TP04513625 34.0 81.8 110.0 112.5 116.9 119.4 110 125 125 125 None - - 20.7 21.7 22.9 23.9 25 25 25 30 2TP04510946 9.0 10.8 20.7 21.7 22.9 23.9 25 25 25 30 460 7.1 54 0.8 3.1 4.1 2.2 2TP04511846 18.0 21.7 30.9 32.2 33.7 34.9 35 35 35 35 2TP04512446 24.0 28.9 40.0 41.2 42.7 44.0 40 45 45 45 2TP04513646 34.0 40.9 55.0 56.2 57.7 59.0 60 60 60 60 None - 15.8 17.0 17.6 18.8 20 20 20 20 2TP04510958 9.0 8.7 15.8 17.0 17.6 18.8 20 20 20 20 575 5.4 44 0.6 2.4 3.6 1.8 2TP04511858 18.0 17.3 24.7 26.2 26.9 28.4 25 30 30 30 2TP04512458 24.0 23.1 31.9 33.4 34.1 35.6 35 35 35 40 2TP04513658 34.0 32.7 43.9 45.4 46.1 47.6 45 50 50 50 * Maximum HACR breaker of the same AMP size is applicable. 18 Unitary Products 036-21058-003—A-1102 22 Oc., 0 N. V 00 CD M 0 V) I. N CO V m u) . N. - > O N N- 00 W m m O > N N N O a CO V O CD N CO V i- N o') _ N CO a) m 0 0 N N t+) CO `- •' - N N N N N N d CO o 0 6V) 0)) /1. O ,- N N m 0 0 0 0 0 m I. in C') CI c) V CO m CD CO 3 v CD O O m CO v m u) n r) m U) ao v uo V) o O N N N O = m u) 00 V m m O 0 N- CD o u O n r N c) m • N N N N N N O M CO V 0) n' OOOjOO oo OOC) C) V) V V V O n m co I. N co co N O m 76 comV V N inCOm u) O O r co , I. O O 0) m 0 0 V N N CV V a 0 u) O O h N O V O CD N 00 V '- I 'n Cn CD O I. n O a0 m O O _ _ N c) CO 7 7 7 `- . . . . . N N N N N ( ' ' 2 O mm mCO m ,C., ,- n CO 0 CD CV in a I. O O N N co V V Cn Cn co a m m m m O O o o O o O O o O O .N.. CO O I. n 0) u) c) V 0) COIn COj N N co co7 V V UN. ) upcoco N m CO V ' ' V t` t O m o O N N c• _ CO N CD O m I. CD N N O V. N O V M cc). V V u) Cn O r` n O m O O N m N N N Ni ' ' 2 O N V N m cD V .- co co co O co Cn 0 N cc)) V in CO CO N- O m 0) o .-- m m m m m m m m m m m m a c' .N. Cn N CD N. c) V I• N m N j m O co V N N CCS) V V c cocoN- CO 0) N O CO 0) O a N N oO C. V O CD N m co co O co O V N O m a0 n = O N N cc) V u1 u) CD I. CO m m 0 co 5 — m , . N N N 1— C C. In Lc, 10Co co IN CO m O O co N CV.) V Cn Cmn co co U) 00 0 0 CO CO CO m m m m 0) m m m m m m 0 x L0 7 ^ o V m V O c^D Com) O CO IN. CND 2) Imn m n 0 CO c0 m m m o `- '— N V u] O N- O m 0 O = N m T o o. N CO CO CO O 0) CO CO O m O N O CO 00 0 0 V 7 u) O n CD O CO N N Z 2 I. r I. N- O CD CD CD CO O In ill LO u) in u) V) O a' N- CO N OO O UN0 00 V. O m m o m rn m rn el I . N V O N O C+) CV O CD O O t` O O N N N. O O co o m m C) 0 CV 00 V N N c') V (C) CND N 0 a u) I. 0) N 0 0 O O O CV CO) I-- O V V V. CO CO CO O m m O O .- W m O O O O O 0 2 n m O N V In N- m N V O N m N V Z a m o N c+) V u) CD I. m 0N o) V O I. O CQ m CO N N- N I. n I. N- I. CO 00 00 CO CO c0 00 cn G s m u) CD ch O V n O '- .- I. O u) I. 0fr O N. I. c0 m m m 0 N N N V I°on W7 a V 03 N I. c) m ID f") O 0) m 0) 0 ^' O = N. I. CO CO m m O CV c) C') V in N LL m x 0 0 0 0 0 w 0- O N I. N N N O c) c0 C') m V m V Cy a V CD N- m o N C') Cn cD CD m N V 1 LL m CD CD CO CD I. N- I. I. N- n 1. c0 c0 CO "j W v cin V I. u) m m V Cn c) O CD N O In N O m CO CO O m 0 O O m 0 0 N V O —t n m cv EL p 2 N- IO. m m O o ^ N CINN- 000') 0 co V O O O O O 3 T N o co V O co N O V O co N O W a c') u') N- O O c) V) O CO m J X CD CD CO (0 N- N- N- I. N- N- N 0 m 2 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 CD I L.L. O O O O O O O o O O O O O O O O O L Ia 0 N N N N N N N N 00) c) coNcoama)) co co) C') co) 2 Unitary Products 23 036-21058-003-A-1102 Prir.-,11,______Ok. q, ____ -A - - _ __ 7:-.T. 11 _� ij --- ; . '11FRONT %' LEFT FRONT B C LEFT A C D A B D E F FIGURE 2 : UNIT 4 POINT LOAD FIGURE 4 : UNIT 6 POINT LOAD TABLE 32: 4 POINT LOAD WEIGHT Location(lbs.) TABLE 33: 6 POINT LOAD WEIGHT Model Locations(lbs.) A B C D Model DM078 228 195 285 333 A B C D E F DM090 230 197 287 336 DM078 156 140 127 185 205 228 DM102 238 203 296 347 DM090 158 142 128 187 207 230 DM120 245 209 305 357 DM102 163 146 132 192 213 237 DM150 262 224 327 382 DM120 168 151 136 198 219 244 DM150 180 161 145 212 235 262 TABLE 34: UNIT WEIGHT Model Shipping Weight(lbs.) Operating Weight(lbs.) DM078 1046 1041 DM090 1056 1051 LEFT FRONT DM102 1089 1084 DM120 1121 1116 DM150 1200 1195 FIGURE 3 : UNIT CENTER OF GRAVITY Unitary Products 33 036-21058-003-A-1102 i ---r---TillIlliill"'I II 30-11/32 50-314 ��, I See Detail `` Power it' Control A PW Entry Entry 92-1/2 ;moi 97/8 1') ...- 4-1/4 4-1/4 i Power r Entry 0 2-1/2 Convenience • .' 1101 Power ��t�� 11-1/2 1I Outlet .. � Yit���� ��I' Entry For Baserail 7/8 ' Dimensions /�-/16 FRONT See Detail B �-�� Far Drain 59 24-3/16 6-3/ 6 . it Dimensions LEFT \I See Detail C j��� 27 8 _...-7 '� FIGURE 5 : UNIT DIMENSIONS DETAIL A Gas Pipe Inlet DETAIL B 2-3/8 5-1/4 r Base , . 017-13/16 Pan 3-3/4 A View of Wall Across from Coil TABLE 35: UNIT CLEARANCES 3-9/16 Top* 72" I Right 12" DETAIL C Front 36" Left 36" '_ Reart 36" Bottom 0" O '_ * Units must be installed outdoors.Overhanging structure or j shrubs should not obstruct condenser air discharge outlet. 5.318 allimmilimiim t To remove the slide-out drain pan,a rear clearance of 60"is IIrequired.If space is unavailable,the drain pan can be removed through the front by separating the corner wall. i 1= Units may be installed on combustible floors made from wood or class A,B or C roof covering materials. 34 Unitary Products Montville Fire Marshal's Office Memo To: Mr.Vern Vesey II From: Fire Inspector Roy(Ed) Shafer Date: 06/04/03 FM02-0687 Re: Osterman Propane, Inc. Propane Line Test at Faria Corp. Dear Vern, Wednesday June 4,2003 I was requested by Osterman Propane who is the contractor to witness a required pressure test on propane line from 2 above ground tanks to an HVAC Unit on outside of building, no problems were observed on this test. Any items that might have been inadvertently overlooked in the plan review do not relieve the owner from achieving code compliance. Should you need further assistance or have any questions,please contact the undersigned at the Town of Montville Fire Marshal's Office at 860-848-1175. Respectfully submitted, Roy(Ed)Shafer Fire Inspector