HomeMy WebLinkAbout2001 - Ground Water Recovery and Treatment Building M Town of Montville Building Department 310 Norwich-New London Tpke. Uncasville, CT 06382 Tel. 860-848-7166 Fax. 860-848-7231 May 21, 2001 Don Sawyer Thomas G. Faria Corporation r 385 Norwich-New London Turnpike Uncasville, CT 06382 RE: Ground Water Recovery& Treatment Building We have received a building permit application for the above referenced property. In accordance with Connecticut General Statute 29-263, your application is being rejected for the following reason(s): 1. No building permit application 2. Construction permit sign-off sheet has not been submitted 3. The foundation and building need to be designed, signed and sealed by a Professional Engineer or Architect. 4. Reuse of the existing stairs may not be feasible, the stairs will have to conform to BOCA section 1014.0 5. Electrical plan has not been submitted 6. Emergency lights and exit signs are not indicated 7. We are requesting that an Architect or Professional Engineer be retained to prepare the building plans and to do a through review of the building code due to the close proximity of this building to the main building. Fire ratings and fire separations have to be addressed. 8. The piping plan indicates that some piping and the vent stack will be supported from the building structure; proof that the structure was designed to accommodate these additional loads will have to be submitted. 9. Submit a site plan indicating all structures and delineate the flood zones on the property. We will keep all documents received to date on file and renew your application when you have furnished all the required data. Thank you, ;,7\ G./ C =septi J. Summers Asst. Building Official -- /z vne Cc: File Zoning Dept. Inland-Wetlands � S • Plan Review Guide 1996 BOCA Job Location Job Description cT -1-f-e-,,rMt-tr- - V-CrO ' Owner Contractor Address Address City State Zip City State Zip List of Required Corrections Code Section Description of Correction Required lv�y.0 s-fp ro Censi rzr\ , ex)s-ri'4 rze- oc.'rz3r T, (v i.b-r 705.z G XT. vi i-o '�',r,c '► c g f't orL 7oS.6 C-n�,sldii; o e)(-1-er1vr �C us ADMINISTRATION (Chapter 1) Complete construction documents Signed/sealed construction documents (107.5, 107.6, 107.7) (107.7, 114.1) BUILDING PLANNING (Chapters 3, 4, 5, 6) t� USE OR OCCUPANCY CLASSIFICATION (302.0-313.0) r Z Single Use Group Specific occupancy areas (302.1.1) Mixed Use Groups Accessory areas (302.1.2) GENERAL BUILDING LIMITATIONS (Chapters 5 & 6) Apply Case 1 to determine the allowable height and area and permitted types of construction for a building containing a single use group or nonseparated mixed use groups. Apply Case 2 to determine the allowable height and area and per- mitted types of construction for a building containing separated mixed use groups. AREA MODIFICATIONS TO TABLE 503 %of Allowable tabular area (Table 503) 100% Reduction for height (Table 506.4) — U % perriiimeter 0 3 6 3 Q (506.2) North East South West % Increase for open perimeter (506.2) + 5a% Open % Increase for automatic perim. 6 ft. Perimeter ft. sprinklers (506.3) + 0 %Open perimeter = 5 d Total percentage factor =15 % (Open perim./perim.)x 100% %Tab. area increase = _60 Conversion factor 1,—;47 (506.2 2x(% Open perim. -25%) (Total percentage factor/100%) CASE 1 —SINGLE USE OR NONSEPARATED MIXED USE GROUPS (313.1.1, 503.0) Using Table 503, identify the allowable height and area of the single use group or the most restrictive of the nonseparated mixed use groups. Construction types that provide an allowable tabular area equal to or greater than the adjusted floor area and allowable heights(as modified by Section 504.0)equal to or greater than the actual building height are permitted. Actual floor area ld TO ft.2 Actual building height /S feet I stories Adjusted floor area 7Z--c? ft.2 Allowable building height feet stories 'Adjusted floor area = actual floor area/conversion factor Permitted types of construction A1-1 Type of construction assumed for review (602.3) Z-G CASE 2—MIXED USE SEPARATED USE GROUPS Using Table 503,identify the allowable height and area of each of the separated use groups within the building.Construction types that provide, for each story of the building, tabular areas which result in a sum of the ratios of 1.00 or less and allowable heights(as modified by Section 504.0) equal to or greater than the actual height of the use group are permitted. Use Actual Adjusted Actual Allowable Story Group floor area floor area* height height (Table 503) ft2 ft2 ft stories ft stories ft2 ft2 ft stories ft stories ft2 ft2 ft stories ft stories ft2 ft2 ft stories ft stories ft2 ft2 ft stories ft stories ft2 ft2 ft stories ft stories ft2 ft2 ft stories ft stories 'Adjusted floor area= actual floor area/conversion factor Adjusted floor area* + + + _ <= 1.00 Allowable area (Table 503) Permitted types of construction Type of construction assumed for review (602.3) UNLIMITED AREA ONE-STORY BUILDINGS Use group classification (507.1) School buildings (507.1.1) Building height (story, feet) (507.1) High-hazard use groups (507.1.2) Type of construction (507.1) Exterior walls (507.2) Automatic sprinkler system (507.1, 904.11) MEZZANINES Area limitation (505.2) Openness (505.4) Egress (505.3) SPECIAL USE AND OCCUPANCY (Chapter 4) COVERED MALL BUILDINGS Parking structures (402.15) Tenant separations (402.4) HIGH-RISE BUILDINGS Egress (402.5) Automatic sprinkler system (403.2) Mall width (402.6) Alternative sprinkler modifications (403.3) Structural elements (402.7) Automatic fire detection (403.4) Roof coverings (402.8) Voice/alarm signaling systems (403.5) A-1, A-2 occupancy (402.9) Fire department communication (403.6) Automatic sprinkler system (402.10) Fire command station (403.7) Standpipes (402.11) Elevators (403.8) Fire department access (402.12) Standby systems (403.9) Kiosk requirements (402.14) Stairway doors (403.10) Raymond T.Occhialini TOWN OF MONTVILLE TEL:(860)848-1175 Fire Marshal fire Marshal's Office FAX(860)848-4063 836 Old Colchester Road Oakdale CT 06370-1637 May 29, 2001 Mr. Vernon Vesey H Building Official 836 Old Colchester Road Oakdale, CT 06370 RE: Faria Corporation Water Treatment Building Dear Vern, The Montville Fire Marshal received plans for a new water treatment building at the Thomas Faria Corporation on May 21, 2001. The plans were rejected due to lack of detail on the building including egress and electrical. If you should have any questions please feel free to contact the undersigned at the Montville Fire Marshal's Office. rely yo Occhialini Montville Fire Marshal cc: file Thomas G. Faria Corporation <AIN, --_, Manufacturers of World Class Instrumentation �� -V 'I . 385 Norwich- New London Turnpike, Uncasville, CT U.S.A.06382-0983 Phone: 860-848-9271 Fax: 860-848-2704 Purchasing Fax: 860-447-6226 ', - Internet: www.faria-instruments.com e-mail: faria@faria-instruments.com May 25, 2001 Joseph J. Summers Town of Montville Building Department 310 Norwich-New London Turnpike Uncasville Ct. 06382 RE: Ground Water Recovery&Treatment Building On May 14th I visited your office and the Zoning office seeking advice on how to proceed with this project. I appreciate your taking the time to indicate how to fill out the permit application form and point out what other documentation and services I would need to include with the application. I also appreciate your phone call earlier this week to tell be about some additional requirements. However, I was disappointed to receive your letter of rejection dated May 21,2001. The facts of your letter are not correct. I have not yet submitted a Building Permit Application to your office. I am in the process of gathering the information you requested as of this writing. Also, if I had submitted the application, your number one reason for rejecting it makes no sense. We are under pressure from the EPA to complete this project as soon as possible. It is our intention to comply with all the requirements of the EPA and the Town of Montville. I think it is reasonable to expect that we would all work toward that end with the same degree of accuracy. Therefore, because your letter is the first written correspondence about this project to be part of the tile, our exception to it should also be included. I expect to have the information you requested by next week and when ifs ready I will bring you the package including the Building Permit Application. Ftespectfull rary ce,,,e-/V-c------ Don Sawyer Facilities Manager Cc: File Chris conradi ANSI•RAB /i^� oMs ( 7\ Large Enough to Supply the World- Small Enough for Personal Service * ! r �� Quality•Delivery•Customer Service•Engineering Innovation•Value ((Ai") •--_,./ RERR',IANN son CERTIFIED REGISTRARS.INS •11 ZONING PERMIT IT IS THE APPLICANT'S RESPONSIBILITY TO FURNISH THE FOLLOWING INFORMATION: PROPERTY LOCATION ,71 Z ?/ et//G PO l.Lf MAP 7 5.4 LOT 3 g PROPERTY OWNER 'Tl /.f S F/4/L/ c, CONTRACTOR CONTRACTOR LICENSE# CONTACT ADDRESS TELEPHONE ZONE LOT AREA /V/ Oj STRUCTURE AREA i©)r Co HEIGHT/ NATURE OF REQUEST/PROPOSED USE /2 6/4-, _ •T /3C Ci A SEITC$,OR PROVOS TWO COPIES OF PLANS DRAWN TO A KALI OF AT LEAST r -w SNOwNNG.I INi10Ni OP um LOT,um nap. ANTRA, AND LOCATION OF RIOSTNNG. PROPOfm, NYICIAL AND AcciS OIN STUCT■IIS, BIIVRWAVS, SANITARY FACILITIES AND WATER SUPPLY, PAINING PAC*UTas, AND ADSACISIT STI MITSs Dwram RS OF PROPOM STRONTIUM= PROW NOPLNZTY LDIRs ANO WRTLANDS. A PLAN PWIPAINIP IV A CC1IMICTNCBIT RlOUTNIND LAND SRVIVOR NOV IN TIE PROPOSED INS SPICNPIRD ANIOVR SHALL NOT N ASSNOiNi UNTIL AN ACTRAL CERUPICAMI OF CONNILIANCR a WIRD BY TIN CONNOWSON OR ITS APPOII11I0 AGENTS. Office use only YESN/A cr./ SKETCH PLAN OR GRADING PLAN Jol ❑ y L7.5 HEALTH DISTRICT/WPCA APPROVAL El STATE HIGHWAY PERMIT ❑ �� WETLANDS PERMIT ❑ ❑ HAS A VARIANCE EVER BEEN GRANTED FOR THIS PROPERTY ❑ ❑ HAS BONDBEEN FILED 0 ❑ FEEFEELicasHic Ofr rTj/�,/-'1OS 0 I ZONING PERMIT NUMBER �O - I v�-8 OR ❑WA EXPIRATION DATE 5-4-0 7-- THE _THE APPLICANT IS RESPONSIBLE FOR AND AGREES TO: 1. ADHERE TO ALL THE APPLICABLE REQUIREMENTS OF THE ZONING REGULATIONS, 2. FURNISH ALL NECESSARY INFORMATION AND DOCUMENTATION TO PROCESS APPLICATION. 3. NOTIFY THE COMMISSION OR RS APPOINTED AGENT OF ANY ALTERATION IN THE PLANS. 4 CALL FOR FINAL INSPECTION AND REQUEST CERTIFICATE OF COMPLIANCE BEFORE ISSUANCE OF C. O. 2:APPLICANT'S TURE ,�� �� _ jG�� / � � TE 1 C 4-1-I di DATE //4/ />% \ 4,61--eGn DATE /VC 1"- C C ISSION AGENT CERTIFICATE OF COMPLIANCE THIS SIGNED PERMIT AUTHORIZES THE APPLICANT TO PROCEED TO THE BUILDING DEPARTMENT FOR ANY REQUIRED PERMITS THE SIGNED CERTIFICATE OF COMPLIANCE IS NEEDED PRIOR TO A CERTIFICATE OF OCCUPANCY BEING ISSUED BY THE BUILDING INSPECTOR CONTACT THE ZONING OFFICER (848-8549) AT LEAST 24 HOURS BEFORE CONSTRUCTION BEGINS AND UPON COMPLETION OF PROJECT TO ALLOW ZONING OFFICER TO INSPECT LOCATION. RF./ iif)0w0