Loading...
HomeMy WebLinkAboutFlue Liner 2017 TOWN OF MONTVILLE Building Department 310 NORWICH-NEW LONDON TURNPIKE UNCASVILLE, CT 06382-2599 TEL. (860) 848-3030 X382 FAX. (860) 848-7231 BUILDING PERMIT Permit Number: B2017-0366 Date: 28-Aug-17 Map/Lot: 096/086-000 Owner ID: 5333000 Project Location: 142 PARK AVENUE EXTENSION Unit: Job Description: Reline Oil Flue with Insulated Stainless Steel Liner Owner Nam William E J and Cynthia L Mahn Tenant Name N/A Careof: 142 Park Ave Ext Uncasville _CT 06382- Telephone: (860)848-0298 Applicant Name Jerry White Telephone: (860)376-3393 DBA: Chimney Care Professionals Inc. Lic/Reg Type HIC Lic/Reg N 610458 29 Pleasant View Street Exp Date: 30-Nov-17 Jewett City CT 06351- Construction Value Permit Fees Construction Information Building Value: $1,935.00 Building Fee: $30.00 Use Group: IRC Plumbing Value: $0.00 Plumbing Fee: $0.00 Code: 2016 State Building Code Mechanical Valu $0.00 Mechanical Fe $0.00 Electrical Value: $0.00 Electrical Fee: $0.00 Construction Type IRC Total Value: $1,935.00 Penalty Fee: $0.00 Permit Code: R4 C of 0 Fee: $0.00 Comment Plan Review Fe $0.00 State Ed Fee: $0.50 Total Fee Paid: $30.50 It shall be the owners repsonsibility to schedule the following inspections a minimum of 2 business days in advance: Field set of approved construction documents shall be available onsite during all inspections. BUILDING PERMIT INSPECTIONS PLUMBING,MECHANICAL,ELECTRICAL PERMIT INSPECTIONS ❑ Footing-Prior to pouring concrete ❑ R Plumbing and leak test ❑ Deck Piers ❑ R Electrical ❑ Backfill-Footing drains and waterproofing ❑ Elec Trench-with conduit installed ❑ Concrete Slab-Prior to pouring concrete ❑ Pool Bonding ❑ Anchor Bolts-with sill plate and prior to floor frami ❑ Electrical Service CRS No: n ❑ Framing ❑ R HVAC ❑ Masonry Fireplace Throat or Chimney Thimble ❑ Gas Piping and leak test ❑ Fireblocking Draftstopping INSPECTION REQUIRED UPON COMPLETION ❑ Insulation &I Certificate of Approval Certificat- • Oc u•.ncy Building Official's Approval: .! - ��� Town of Montville Building Department T 310 Norwich-New London Tpke. Tel. 860-848-3030, ExL 82 Uncasville, CT 06382 Fax. 860-848-7231 RESIDENTIAL PERMIT APPLICATION FORM Permit No.: & �—O�4' Type of Work Occupancy Type Permit Type ❑New Construction Single Family ❑Building ❑Addition Two-Family ❑Plumbing ❑Alteration ❑Townhouse ❑Mechanical 0 Accessory Structure 0 Electrical CRS#: Property Address: /Y /? rA 4v.z 6/4:- (Number) f(Number) (Street) (Unit) Job Description: Re-44..e mom/ ../ a S;- // s. S /,,,e.-. Owner: 3,..m :!�-.o/ /2.-7c 4-7 Address: S'z.� { City: State: Zip Code: Telephone( 8'647 ) 1'1,g, - 0-29.1 C — 8?5" y3Y3 Applicant: z:-.,7- JL/ ,/J BBK C �G ir.�r Y C u,„ /�r o SS/o�aa,6 , r C Address: off 7 /'/t Q, , ;rC lVe..r) City: ✓e e r, State: Cr Zip Code: 063.57 Telephone( IdD ) .376 - 3373 Contractors - Complete the Following: �3Y7vse2 License Type: hi-2—C License No.: '/ 2 yS$' Expiration Date: //0A7 I hereby certify that the proposed work will conform to the State Building Code and all other codes as adopted by the State of Connecticut and the Town of Montville and further attest that the proposed work is authorized by the owner in fee and that I am authorized to make application for a permit for such work as described above. By checking this box, I will follow the requirements of the 2005 NEC as the alternative compliance per section E3301.2.1 of the Residential Code, instead of the electrical requirements in chapters 33 through 42 of the Residential Code. Owner/Agent Signature: 4)12"-- Date: 3/2,577 Construction Value "31: Permit Fees Building Value: Building Fee: Plumbing Value: Plumbing Fee: Mechanical Value: /c; J Mechanical Fee: Electrical Value: Electrical Fee: Total Value: - Penalty Fee: C of 0 Fee: Plan Review Fee: State Ed Fee: - 60 Total Fee: 3n .so 4 wedit ugust 23,2007 Town of Montville Building Department File Receipt Date: 25-Aua-17 ReceiptNo: 12597 Received From: Chimney Care Professinnals Job Address: 142 Park Ave Ext Town Fees Collected State of Connecticut Fees Collected Bldg Cash: 10.00 State Cash: 10.00 Bldg Check: 13050 State Check: 10 50 Bldg Credit: 10.00 State Credit: 10.00 Fire Cash: 10.00 Fire Check: 10.00 Fire Credit: 10.00 Construction Value: 11 935.00 Demolition $0.00 CheckNo: 4151 Received By: Vernon D Vesey II Court 142 Park Ave Ext ITEM QTY $/UNIT TOTAL Building Plumbing Mechanical Electrical BUILDING AREA Basement,Finished SF $ 41.96 $ - $ - Interior Renovations SF $ 36.09 $ - $ - $ - AMENITIES Kitchen EA $ - $ - $ - Full Bathroom EA $ - $ - Half-Bathroom EA $ - $ - GARAGE Detached SF $ 71.53 $ - $ - MECHANICAL Warm-Air n Y/N $ - Hot Water n Y/N $ - Electric n Y/N $ - Air Conditioning n Y/N $ - ELECTRICAL SERVICE Upgrade Amps $ - Subpanel EA $ 699.00 $ - Gen Set EA $ 3,850.00 $ - SOLID FUEL BURNING APPLIANCES Prefab Metal Fireplace EA $ 6,497.70 $ - Masonry w/tfreplace EA $ 7,096.65 $ - Masonry w/2 fireplaces EA $ 11,095.70 $ - Wood Stove,free standing EA $ 2,692.25 $ - Wood stove insert EA $ 1,859.77 $ - DECKS,PORCHES,SUNROOMS Deck SF $ 44.07 $ - Porch SF $ 149.38 $ - Sunroom SF $ 176.90 $ - $ - POOLS&HOT TUBS Hot Tub EA $ 8,016.25 $ - $ - Inground Pool EA $ 31,550.00 $ - $ - Above Ground Round EA $ 6,299.46 $ - $ - Above Ground Oval EA $ 7,019.75 $ - $ - Pool Heater EA $ 8,984.25 $ - $ - Inflatable Type Pool EA $ 1,200.00 $ - $ - SHEDS w/o electrical SF $ 25.55 $ - w/electrical SF $ 26.85 $ - $ - RENOVATIONS Roofing,Overlay SF $ 3.50 $ - Roofing,Strip&reroof SF $ 4.50 $ - Roof Sheathing SF $ 1.51 $ - Siding SF $ 6.75 $ - Windows EA $ 550.00 $ - Skylights EA $ 1,051.10 $ - Doors,Exterior EA $ 601.50 $ - Oil Tank,275 Gallon EA $ - Oil Tank,550 Gallon EA $ - MISCELLANEOUS CALCULATIONS $ 1,935.00 Solar Install n TOTALS $ - $ - $ 1,935.00 $ - PERMIT FEE CALCULATIONS Construction Value Fee Building $ - $ - Plumbing y $ - $ - Mechanical y $ 1,935.00 $ 30.00 Electrical y $ - $ - Plan Review Fee y $ - Certificate of Occupancy Fee $ - Plan Review Fee $ - State Education Fee $ 0.50 TOTALS $ 1,935.00 $ 30.50 Figures are based on the 2006 RS Means Residential Cost Data ACO D CERTIFICATE OF LIABILITY INSURANCE TE(Mkt ;n i THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT Jane Lataille NAME: Paradiso Financial & Insurance Services, LLC PHONEO (860)684-5270 i(FNNo):(860)851-9564 8 East Main Street MLs:jlataille@paradisoinsurance.com INSURER'S)AFFORDING COVERAGE NAIC I Stafford Springs CT 06076 INSURER AArCh Ins INSURED INSURER B Nautilus Insurance Co Chimney Care Professionals Inc INSURERcNCCI-HARTFORD CAS INS CO 29 Pleasant View St INSURER D: Jewett City, CT 06351 INSURERE: INSURER F: COVERAGES CERTIFICATE NUMBER:CL1732100209 REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR ADDL SUER POLICY EFF POLICY EXP LTR TYPE OF INSURANCE Ml INSD WVD POLICY NUMBER (MM/DDIYYYY)I(MDD/YYYY) UMITS X COMMERCIAL GENERAL LIABILITY 1,000,000 EACH OCCURRENCE S A CLAIMS-MADE X OCCUR , DAMAGE TO RENTED 100,000 PREMISES(Ea occ mance) I$ AGL0030227-01 10/5/2016 10/5/2017 MED EXP(Any one person) ; 10,000 PERSONAL BADV INJURY $ 1,000,000 GE 'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE _ S 2,000,000 PRO- X POLICY I LOC JECT PRODUCTS-COMP/OP AGG S 2,000,000 OTHER: $ AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT S — (Ea accident) ANY AUTO BODILY INJURY(Per person) $ ALL OWNED SCHEDULED BODILY INJURY(Per acodent) S AUTOS _ AUTOS NON-OWNED PROPERTY DAMAGE _ S HIRED AUTOS AUTOS (Per accident) - ; X UMBRELLA UAB OCCUR EACH OCCURRENCE S 1,000,000 B EXCESS UAB I CLAIMS-MADE AGGREGATE S 1,000,000 DED I I RETENTION; AN032169 10/5/2016 10/5/2017 i S WORKERS COMPENSATION X PER OTH- !AND EMPLOYERS'WABIUTY Y/N STATUTE ER !ANY PROPRIETOR/PARTNER/EXECUTIVE E.L.EACH ACCIDENT ; 100,000 'OFFICER/MEMBEREXCLUDED? Y N IA C i(Mandatory In NH) 6S60UB-0088N96-0-16 10/19/2016 10/19/2017 EL.DISEASE-EA EMPLOYE S 100,000 !M yes,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ 500,000 1 I I DESCRIPTION OF OPERATIONS I LOCATIONS/VEHICLES (ACORD 101,Additional Remarks Schedule,may be attached If more space Is required) STATE OF CONNECTICUT DEP I RTSII:A T OF(.0.\S1 I? PRO TE('TI(1 A HOME IMPROVEMENT CONTRACTOR CHIMNEY CARE PROFESSIONALS INC CANCELLATION 29 PLEASANT VIEW STREET SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE JEWETT CITY,CT 06351 THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. ------------.......1 EFFECTIVE EXPIRES AUTHORIZED REPRESENTATIVE _lc REG NO 11/30/2016 HIC.06104588 12/01/2015 Jane Lataille/JLATAI e-4---1.0 ©1988-2014 ACORD CORPORATION. All rights reserved. e and logo are registered marks of ACORD Town of Montville Building Department CONSTRUCTION PERMIT APPROVAL Applicant is responsible for obtaining all of the required approvals. No .ermit will be issued until all the re.uired si.natures are obtained. Property Address Job Description Required Department Permit Issuance Approval Approval ` ® Tax Collector ,�/�/�(��–r--�— .4.2s/ 7 Signature/date Comments: Planning &Zoning Signature/date t Comments: Fire Marshal I?/ Signature/date / / Comments: ❑ Health Department Required for properties with private septic or well Comments: WPCA, Administrative �r^��K „L.)" 71 A) � � /l Required for properties on sewer Signature/date Comments: ❑ WPCA, Operations When Required by WPCA Signature/date Comments: ❑ Department of Public Works Required when project includes driveway work or certain drainage requirements Signature/date Comments: ❑ Montville Police Department • Required for all permits EXCEPT one and two family residential Signature/date Comments: ❑ State Dept. of Transportation Required for Structures over 100,000 sq.ft or with more than 200 parking s.aces-Official co• of STC Certificate of O.eration re.uired–.er CGS 14-311 Signature/date Building Department Review Complete Signature/date Red Mag 23,2011 Phone:888-900-8106 Fax:888-392-4432 _ Web:www.NewEnglandChimneySupply.com mi 34 Commerce Street,Williston VT 05495 i New England Supply . 1.)CHIMNEY PREPARATION &INITIAL INSPECTION Before any liner can be installed the existing chimney must meet properconstruction and code requirements: • The chimney must be between 10-ft high(min)and 100-ft(max)in height. • The chimney must have a wall thickness of 4-inch min(nominal)solid masonry unit. • The chimney must project at least 3-ft over the point of roof penetration,and at least 2-ft higher than any point of any structure within a 10-ft radius. • If the mass of the chimney is constructed within the structure a 2-in minimum,unobstructed air space,must surround the chimney mass to any combustible material. If the chimney is constructed on the outside of the structure, 1-in of unobstructed air space must be maintained between the chimney mass and all other combustible materials. • When the chimney breaks the plane of a floor,ceiling,or other horizontal or vertical structure,fire stops of a non-combustible material must be used. • The installer must verify the above with all local&national codes as required. • If the correct clearances cannot be verified due to regional factors the liner must be installed with a UL listed insulation material. • Any appliance that burns a liquid fuel cannot be attached to a chimney liner made to vent a solid fuel burning appliance. • The connection pipe between the appliance and the chimney liner must have proper clearances to combustibles. This can be determined by the appliance manufacturer's installation instructions,the national building code,the local building code,or whichever factor takes precedence. • The chimney must be cleaned comprehensively to remove all deposits of soot,creosote,or glazed creosote before any liner is installed.A full inspection must be done to determine if the chimney is structurally sound. If the integrity of the chimney is found to be substandard with missing, loose,or cracked masonry or mortar joints,the chimney must be repaired before installation of the chimney liner can occur. CHIMNEY CONNECTORS AND VENT CONNECTORS 2.)SIZING THE CORRECT CHIMNEY LINER DIAMETER • For sizing a liner used for gas and oil burning appliances refer to N.F.P.A 54 for gas and N.F.P.A 31 for oil.Also refer Mnimumchrtimey - to bock and combustibles 1.4 System A.Minimum 3sin.(90 mm)thrck brick masonry wad framed into 2 in.151 05051 combustible wall with a minmum of 12 in.(305 mm)brick separation to the appliance manufacturer's instructions. Liners that -�„ S.+t♦ Minimum clearance from clay liner to combustibles Fireclay liner(ASTM C 315 ;A . to2 in.(305 mm) r M ,bre Standard Specification for Clay Flue Liners and Chimney Pots,or equivalent), are incorrectly sized for the appliance can lead to operation j minimum%in.(16mm)wall thdrnees.shall run from outer surface -r- of bnd,neat to,but not beyond.the inner surface of chimney flue problems and condensation inside the lining system. Please �i liner and shall be firmly cemented in place call New England Supply Inc.should you have any questions ' `„,e I cam'tor Clearance:12 in.(305 mm) about sizing a liner. . p Fireclay Minimum 12 in.(305 05111 Masonry pnimrre •- y - liner • For sizing a liner used for solid fuel burning appliances the tetonwastibes constructed to NEPA 211 cross section area of the liner shall not be less than the cross section area of the appliance outlet collar.Unless specified Minim°m chimney steam.ham System B.Solid-insulated,listed factory-built chimney length of the same masonry to shesteel supports and Minimum n. by the appliance the cross section area of the flue shall not ` combustibles 2 in.(51 mm) clearance ins mm)or or as the chit with a mini umand 9av(2ing29m � 9 m.1228 mml (25 mm)or more of insulation with a minimum 9 in.(229 mm) be more than three(3)times the cross section area of the Fad°_wm Nnnsarye air space between the outer wall of the chimney length and � nY le refractory Chimney combustibles. appliance outlet collar. Solid fuel burning fireplace liners a ngth cement On conceder The inner end othe dhimneylength shall beflush with the Chimney lenge) inside of the masonry chimney flue and shalt be sealed to the flue should be a minimum of one-twelfth(1/12)the square inches '- flush wiN inside and to the brick masonry penetration withnon-watersoluble I of nue -I use chimney refractory cement.Supports shall be securely fastened to wall compared to the square inches of the fireplace opening. ' mrrs parts to surfaces on alt sides. This one-twelfth(1/12)number can vary based on height of 11}9n 9mm)mim. chkmney(1.• ��., Lonhrefr ed or Fasteners between supports and the chimney length shall not flue 1 penetrate the chimp liner. sotia,nsula,ed, the chimney along with other calculating factors.Call New MaSpnyw listed a pry buitl Clearance:9 in.1229 mm England Supply Inc.if you have any questions. •"•"'°"F`"211 myle gh Sheet steel supports Minimum chimney clearance to sheet j System C.Sheet steel chimney connector.minimum 24 gauge[0.024 in. 3.)DETERMINE IF THE LINER SIZED IN STEP#2 WILL FIT steel 51mrnsandmmb snores (0.61mm))inhoidess,withaventilatedthimble,minim°m 2'05.(St mm) milTwo air ithannels 24 gauge[0,024 in.(0.61 0505)1 in thickness,having two 1 in. cam 1 in.(25 mm) (25 mm)air channels,separated from combustibles by a minimum INTO THE CHIMNEY 4 ,1 J Chimney of 6 in.(152 mm)of glass fiber insulation Opening shall be covered and thimble supported with a sheet steel support,minimum 24 gauge • The BEST-Flex Stainless Steel ChimneyLiner can be installed \•�� °^ (0.024 In.(0.61 mm)]in thickness. inside the existing flue tile or the flue tile can be removed. v�0 ' s°ppnlbts ssizell besecand hold chimney section.Fasteners all rsused ' „� Minimum s le and shall be sized to fit and hold chimney section.Fasteners used �/ Cn;coney (154 mml tion to secure chimney section shall not penetrate chimney flue liner. It is critical that the correct size liner will actually fit into the Twovenoe,edair nae = (15Mie2mm) cnamets.eacn +�� Clearance:6 in.(152 mm) flue. Chimney construction and flue offsets may change the ,in,25mm,; Masonrychimney' . physical size of the interior of the chimney. It is best to test the =NT°I constructed tNFPA211 sheetsteelsupper,e smallest point of the chimney interior before trying to install the chimney liner.Lower a short piece of the correct size liner Minimum mvwy clearance o heat creel ppm sad System D.Solid-insulated.listed factory-bolt chimney length web an Inside down the chimneyto see if it will fit through,or a linerguide ,mWsnwes 2;o.(51 mm) diameter 2 in.(51 mm)larger than the chimney connector and haying g 1 in.(25 mm)or more of insulation,serving as a pass-through fora single k sneer steel , y gauge[0.024 in. cone.If the chimney liner needs to be insulated extra space her ,,pod s ^ ^«tin(5t mm waw sheet steel dmmne connector of z4 _.r (0.61 mm)[thickness,with a minimum 2 in.(51 mm)air space between the around the liner is required. If a round liner configuration ,. Chimney �,., n125 ting woe outer wall of chimney se tion and combustides mo section i "' to chimney l Minimum length of chimney section shall be 12 In.(305 mm).Chimney will not fit the liner can be formed into an oval shape to fit. - 1111=1. section concentric with and spaced l in.125 mm)away from connector by Cmmney means of sheet steel support plates on both ends of chimney section. However an oval liner will change the cross section area and a 1 'co^nector i Opening shall be covered.and chimney section supported on both sides with IR ""�'"Chimney connector sheet steel supports of minimum 24 gauge[0.024 in.(0.61 mm)]thickness. larger liner may be needed. Please call New England Supply \. ,,lCb,m�y �,b Supports shall be secureg fastened to wall surfaces on all sides Air space 2 in.(51 mm) 54. shall be sized to fit and hold chimney section.Fasteners used Inc.with any questions. Manorry cni,,,,,y„Y Sleet steel supports to secure chimney section shall no,penetrate chimney flue liner. Constructed N NFFR 211 Clearance:2 in.(51 mm) Note:All clearances and thicknesses are minimums;larger clearances and thicknesses are permitted.