Loading...
HomeMy WebLinkAboutSFR 2017 TOWN OF MONTVILLE Building Department 310 NORWICH-NEW LONDON TURNPIKE UNCASVILLE, CT 06382-2599 TEL. (860) 848-3030 X382 FAX. (860) 848-7231 BUILDING PERMIT Permit Number: B2017-0362 Date: 28-Aug-17 Map/Lot: 029/064-000 Owner ID: 680001 Project Location: 225 CHESTERFIELD ROAD Unit: Job Description: New Single Family Residence Owner Nam Sunmar/RAF Builders LLC Tenant Name N/A Careof: 511 Mohegan Avenue Pkwy Quaker Hill CI 06375- Telephone: (860)608-0995 Applicant Name Property Owner Telephone: DBA: Lic/Reg Type Lic/Reg N 0 Exp Date: Construction Value Permit Fees Construction Information Building Value: $183,636.00 Building Fee: $1,840.00 Use Group: IRC Plumbing Value: $18,375.00 Plumbing Fee: $190.00 Code: 2016 State Building Code Mechanical Valu $11,106.00 Mechanical Fe $120.00 Electrical Value: $7,372.00 Electrical Fee: $80.00 Construction Type IRC Total Value: $220,489.00 Penalty Fee: $0.00 Permit Code: R2 C of 0 Fee: $25.00 Comment Plan Review Fe $225.00 State Ed Fee: $57.33 Total Fee Paid: $2,535.33 It shall be the owners repsonsibilitv to schedule the following inspections a minimum of 2 business days in advance: Field set of approved construction documents shall be available onsite during all inspections. BUILDING PERMIT INSPECTIONS PLUMBING,MECHANICAL, ELECTRICAL PERMIT INSPECTIONS ❑d Footing-Prior to pouring concrete ❑d R Plumbing and leak test ❑ Deck Piers ❑d R Electrical • Backfill-Footing drains and waterproofing 111 Elec Trench-with conduit installed 0 Concrete Slab-Prior to pouring concrete ❑ Pool Bonding © Anchor Bolts-with sill plate and prior to floor frami ❑d Electrical Service CRS No: 0 d❑ Framing 0 R HVAC ❑ Masonry Fireplace Throat or Chimney Thimble ❑ Gas Piping and leak test ❑Q Fireblocking Draftstopping INSPECTION REQUIRED UPON COMPLETION ❑d Insulation ❑ Certificate o Approval i -.4-of Occupancy Building Official's Approval: 411111 . i _e i c 0 Town of Montville Building Department ODCVOUV°L° 310 Norwich-New London Tpke. Tel. 860-848-3030, Ext 382 Uncasville, CT 06382 Fax. 860-848-7231 RESIDENTIAL PERMIT APPLICATION FORM Permit No.: ? a017-O a T e of Work Occupancy Type ermit T e New Construction Single Family Building Addition Two-Family Plumbing '� 0 Alteration 0 TownhousecY "�� 0 Mechanical 0 Accessory Structure 0 Electrical CRS#: Property Address: 4' 76 Cor ,1/tY"/t 6 ,Qi (Number) (Street) (Unit) Job Description: Ne-41- . "/A,i tC 4S/ - a0404e/4-1 - 74/0 SR'A J - 3 €e d•5" d•A I Owner: llNj4Z ,#!/LOGZS L&e.-- Address: S// /I/lige-94A/ 4 t/& ReZilY City: Q6A-, ,t t4LJ 7 State: v j Zip Code:.6;lY 3 Telephone(OP' )40/ - Q��.5 7s Applicant: - T7t1 DBA: Address: City: State: Zip Code: Telephone( ) - Contractors - Complete/ th/e Following: License Type: "�" License No.:OaVa(�,,,3 Expiration Date: 9•-30 070/ 7 I hereby certify that the proposed work will conform to the State Building Code and all other codes as adopted by the State of Connecticut and the Town of Montville and further attest that the proposed work is authorized by the owner in fee and that I am authorized to make application for a permit for such work as described above. By checking this box, I will follow the requir>- - - of the 2014 NEC as the alternative compliance per section E3401.1 of the Residential Code, instead of the electrical requirements in • apters :4 through of the Residential -:e. Owner/Agent Signature: / L _----- Date: 7.S•/7 Construction Value Permit Fees Building Value: I SY 5 Lt 3(o Building Fee: ( a4O Plumbing Value: (S- 31 Plumbing Fee: I GI 0 Mechanical Value: I I 101,0 Mechanical Fee: 1 aC) Electrical Value: 131 Electrical Fee: SU Total Value: 900 45-q Penalty Fee: C of O Fee: as Plan Review Fee: as 2). State Ed Fee: 57 3.3 Total Fee: 07 5 35.3 3 / Revised August 23,2007 /`" State of Connecticutco c:, 7 B j Workers§ $ : ' Compensation Commission cn :� tt *�( C " Please TYPE or PRINT IN INK itzzzts � sl e. Proof of Workers' Compensation Coverage when Applying for a Building Permit for the Sole Proprietor or Property Owner who WILL act as General Contractor or Principal Employer APPLICANT FOR BUILDING PERMIT ^^ /� Name of Applicant for Building Permit \i/A/4J/Pc- ,4'.4„4" ,&/,..._4)Cl2S L�� Property located at e"?�,,` CyeS'TG G� /zip /_4 in theCity/Townof 445^o-- [Le ATTEST If you are the owner of the above-named property or the sole proprietor of a business doing work on the site of the construction project at the above-named property and you WILL act as the general contractor or principal employer,you must provide proof of workers'compensation insurance coverage for all employees. Complete this form and,if applicable,sign the Affidavit below in the presence of a Notary Public or a Commissioner of the Superior Court. CHECK ONE (1) BOX ONLY, provide the appropriate information, and sign: ❑ I am the OWNER of the above-named property.I WILL act as the general contractor or principal employer and,as such,will submit proof of workers' compensation insurance coverage for all employees who are doing work on the site of the construction project at the above-named property. Signature of OWNER Applicant ❑ I am the SOLE PROPRIETOR of a business doing work at the above-named property.I WILL act as the general contractor or principal employer and,as such,will submit proof of workers'compensation insurance coverage for all employees who are doing work on the site of the construction project at the above- named property. Signature of SOLE PROPRIETOR Applicant I am the OWNER of the above-named property or the SOLE PROPRIETOR of a business doing work at the above-named property.I will not personally 0-1( submit proof of workers'compensation insurance coverage,but I will attest to the following: AFFIDAVIT I hereby swear and attest that I will require proof of workers'compensation insuran - . every contractor, subcontractor,or other worker before he or she does work on t •site of the - 'ion project at the above-named property in accordance with - e n 31-286b o/ a Wo ::tion Act. Signature of OWNER or SOLE PROPRIETOR Applicant Fr . .A,' Name of Business—if applicable �4Iv/11,gaoegC-- 44 y/L:4• 6:71< / L e... Federal Employer ID#(FEIN)-if applicable rh Subscribed and sworn to before me this S day of ,J u Il , 20` I 1__ Signature of Notary Public/Commissioner of the Superior Court 06../41,`- -A (Y\ L__Ain_j___Sixild CARMEN M. KNEEL.Ar t) T7/117.4RY PTrRT Ir 1 MY COMMISSION EXPIRES OCT.31,2017 I Town Department own of Montville CONSTRUCTION PERMIT APPROVAL ams e/ieS /ei.6 /eo Property Address Nell/- S/A/9Ger d /y/L,y - ('L0N/4L - 3 8,- - ...AS- €4 Job Description Required Department Permit Issuance Approval Approval • Tax Collector ,G(,,���/ /Y ' 7/51/ 7 Signature/date Comments: ® Fire Marshal61/J•/I 7 f/(6."'"'D Signature/date Cments: i 9 Planning &Zonin --.r.,-- 7/7/ Required for all permits except Signature/datee Plumbing,Electrical,Mechanical,Roofing, , •ows&Doors ❑ Health Department Required for properties with private septic or well Signature/date x Comments: A t l-'4..4 ❑ WPCA, Administrative Required for properties on sewer nature/date Comments: t A; ❑ WPCA, Operations When Required by WPCA Signature/date omments: Department of Public Works I _ j Required when project includes driveway work or certain drainage requirements mature/date Comments: - ❑ Montville Police Department i Required for all permits EXCEPT one and two family residential Signature/date i Comments: ❑ Copy of State Dept. of Transportation Certificate Required for Structures over 100,000 sq.ft.or with more than 200 parking spaces-Official copy of STC Certificate of Operation required-per CGS 14-311 Signature/date Building Department Final Inspection Revised March 23,2015 Town of Montville Building Department File Receipt Date: ReceiptNo: 12578 Received From: Job Address: 225 Chesterfield Rd. Town F c Collertpd _State of Connectic_ur p es roll ctpfi Bldg Cash: on State Cash: 50.00 Bldg Check: 53S State Check: Bldg Credit: n0 State Credit: 0 n0 Fire Cash: 0 00 Fire Check: Fire Credit: _ULM_ Construction Value: ���o ase nn CheckNo: X74 Demolition Value: Received By: David Jensen Address: 225 Chesterfield Rd. ITEM QTY $/UNIT TOTAL Building Plumbing Mechanical Electrical BUILDING AREA New Construction 1536 SF $ 105.14 $ 161,495.04 $ 4,085.76 Basement,Finished SF $ 25.96 $ - $ - Basement,Unfinished 768 SF $ 12.40 $ 9,523.20 $ 309.54 Crawl Sapce SF $ 9.30 $ - Interior Renovations SF $ 36.09 $ - $ - $ - AMENITIES Kitchen 1 EA $ 9,507.84 $ 1,985.50 $ 678.81 Full Bathroom 2 EA $ 12,570.62 $ 205.70 Half-Bathroom 1 EA $ 3,818.50 $ 102.85 GARAGE Attached SF $ 56.35 $ - $ - Detached SF $ 71.53 $ - $ - Under SF $ 11.03 $ - $ - Carport SF $ 19.89 $ - MECHANICAL Warm-Air n Y/N $ - Hot Water y Y/N $ 11,105.28 Electric n Y/N $ - Air Conditioning n Y/N $ - ELECTRICAL SERVICE Overhead,new 200 Amps $ 1,989.24 Underground,new Amps $ - Subpanel EA $ 599.50 $ - Gen Set EA $ 3,850.00 $ - SOLID FUEL BURNING APPLIANCES Prefab Metal Fireplace EA $ 6,497.70 $ - Masonry w/lfireplace EA $ 7,096.65 $ - Masonry w/2 fireplaces EA $ 11,095.70 $ - Wood Stove,free standing EA $ 2,692.25 $ - Wood stove insert EA $ 1,859.77 $ - DECKS,PORCHES,SUNROOMS Deck 80 SF $ 38.87 $ 3,109.60 Porch SF $ 149.38 $ - Sunroom SF $ 176.90 $ - $ - TOTALS $ 183,635.68 $ 18,374.62 $ 11,105.28 $ 7,371.90 PERMIT FEE CALCULATIONS Construction Value Fee Building $ 183,636.00 $ 1,840.00 Plumbing y $ 18,375.00 $ 190.00 Mechanical y $ 11,106.00 $ 120.00 Electrical y $ 7,372.00 $ 80.00 Working before Permit Issuance n $ - Certificate of Occupancy Fee $ 25.00 Plan Review Fee $ 223.00 State Education Fee $ 57.33 TOTALS $ 220,489.00 $ 2,535.33 Town of Montville Building Department Residential Plan Review Form Date: 7/P//7 Job Address: 2 2 .S C 1j e S rev.. Fie Irl rd. Job Description: Ale LA.-, P R Your permit application is being rejected for the items checked off or commented on. The required information must submitted for review(two sets are required) (C.G.S.29-252a.) This list is offered as a guideline only. It is not meant to be all-inclusive for every permit application,nor is it meant to take the place of the State Building Code. SUPPORTING DOCUMENTATION FLOOR PLAN „Permit application not completed No plans submitted or insufficient information Permit fee due$ Z 51.3�' 4 ./ P'rrnit F a t e c_t _.{__ Basement floor plan required Second floor plan required Worker's comp.affidavit or worker's comp.certificate to be submitted Dimensions not provided or insufficient Copy of contractor's registration or license required Kitchen layout not provided Constntction pennit sign-off sheet required with appropriate approvals,it shall Bathroom layout and space clearances are insufficient be the applicant's responsibility to obtain the required signatures Ceiling heights not identified or insufficient Affidavit required from the bolder of the registration or license authorizing you Attic access location and size not indicated or insufficient to apply for a pennit with their information Attic access must be in a readily accessible location(not over shelving) Provide supporting documentation to show compliance with the 2012 IECC Use of room(s)not identified or unclear (www.enerzvcodes.eov)OR Plans required for the existing residence for each floor with dimensions • One-and Two-Family Dwellings with<15%glazing area to conform to the requirements of section N1102.1 • Townhouses wills S 25% glazing area to confonn to the requirements of WINDOWS&DOORS section N1102.1 q Door sizes not identified Window size&type not identified Two sets of construction documents and other supporting data shall be Emergency escape&rescue opening required.Basements,habitable attics and submitted to the building official at the time of application for the building every sleeping room shall have at least one operable emergency escape and permit.(R103.1) rescue opening.R310.1 =CT,Building Code 2016 Documents are copyright protected,provide original plans or a letter from the Indicate the required light and ventilation for each habitable room or space designer authorizing the duplication of the plans. Field set of the approved constnwtion documents are required to be picked up Indicate the bedroom egress window Egress window sill height not identified from our office and insist be available on site during all inspections Construction documents shall be of sufficient clarity to indicate the location, Window header size not identified or insufficient Door header size not identified or insufficient nature and extent of the work proposed as per section R106.1.1 Construction documents do not match the orientation of the structure on the Window well details not provided or insufficient site plan Glazing—Hazardous locations per section R308.4 WIND LIMITATIONS Submit supporting data to show confonnance with the wind limitations GARAGE and CARPORTS (3 second gust(rd 105 mph) No plan submitted or insufficient information provided Design publication needs to be identified(WFCM or ICC or ASCE or AISI or Building section required the IBC(International Building Code) Opening protection between the garage and residence is not identified or Documents required to be stamped and signed by a CT registered Professional insufficient per section R309.1 Engineer Separation between the garage and the residence is not identified or insufficient Documents insist be designed to either per section R309.2 • Wood Frame Construction Manual • ASCE 7 ELEVATIONS • No plans submitted or insufficient information SSTD 10 Plans do not match the floor plans Documents required to be stamped and signed by a CT registered Professional Finish grade not identified or does not match the site plan Engineer if based on ASCE 7-02 or WFCM chapter 2 Building height(s)not identified Braced walls not identified on the construction documents or are insufficient Dimension height of chimney Braced wall calculations required Roof pitches not identified Ridge connection not identified or insufficient Roof-to-wall connection not identified or insufficient BUILDING SECTIONS&DETAILS Wall-to-wall connection not identified or insufficient Full building section not provided or insufficient Wall-to-sill connection not identified or insufficient Floor-to-floor heights not identified Wall-to-deck connection not identified or insufficient Additional sections and details required Deck-to-foundation connection not identified or insufficient Draft stopping details not provided or insufficient Provide engineering data for the piers to resist gravity,lateral,shear and uplift loads,stamped and signed by a CT licensed design professional STAIRS Hold-down devices,location and type not identified or insufficient Foundation anchor spacing not identified or insufficient Stair not shown on the basement floor plan Construction documents do not match the engineering data submitted Stair not shown on the second floor plan Cold-formed steel framing shall be designed in accordance with COFS/PM- Riser height not identified or insufficient 2002 edition Tread depth not identified or insufficient Nosing required for closed riser stairs SITE PLAN Riser opening can not allow the passage of a 4"sphere Plans required Winder stair—detailed plans required Plans do not match the building plans Spiral stair—detailed plans required Finish floor elevation not indicated Stair width required to be minimum of 36"above the required handrail height Distance from the property line(s)to the structure not identified Handrail detail not provided or insufficient detail Structure dimensions not provided Guardrail detail not provided or insufficient detail Existing and proposed contours are not provided or insufficient Headroom height not identified or insufficient Footing drain discharge not identified 36"landing required at the bottom of the stairs Utilities not provided(electrical,phone,cable,sewer,water,gas) 36"landing required ate top of the stairs Delineation of flood hazard areas and design flood elevation is required per Frost protection required,provide details and connections section R106.1.3 Private sewage disposal system to be identified along with all technical and soil WALLS data. Stud size and spacing not provided or insufficient Grading is to slope away from the building,provide more detailed information Sheathing type not provided or insufficient Plan submitted is not the same plan that has been approved by the Zoning Department and/or Health Department FLOOR FRAMING Plans required showing joists,beams and openings Retaining wall—construction documents required Retaining wall documents required to be stamped and signed by a Connecticut Bearing partitions not provided or indicated Registered Professional Engineer Framing direction not indicated or unclear Beam span&size not provided or insufficient —1 FOUNDATION Joist span,size&spacing not provided No plans submitted or insufficient information Joist's over-spanned Dimensions required Beam over-spanned Wall thickness not identified Provide design data for all unaligned wall and floor bearing points Footing size not identified Point loads not identified on beam data Frost protection not identified or is insufficient Framing less than 18"to grade to be pressure treated or decay resistant Steel beam — must be stamped and signed by a Connecticut Professional Column type,size,spacing not identified or insufficient Waterproofing details not provided or insufficient Engineer Pier type,size and anchor details not provided or insufficient LVL's—engineering data required Engineered foundation plan required I-joists—engineering data required Crawl space ventilation,location,type and size not provided or insufficient Design loads not provided or insufficient Crawl space access,location and size not provided or insufficient Soil testing data required in the area of the proposed structure and shall be made by an approved agency using an approved method,R401.4) WpviredJuly 10,2017 Town of Montville Building Department CEILING FRAMING Plans required showing joists,beams and openings FLOOD-RESISTANT CONSTRUCTION(R323) Bearing partitions not provided or indicated Documentation required to be submitted for the connection,anchored to resist Framing direction not indicated flotation,collapse or permanent lateral movement Beam span&size not provided or insufficient Delineation of flood hazard areas,floodway boundaries,and flood zones and Joist span,size&spacing not provided the flood design elevation to be identified on the site plan(R106.1.3) Joist's over-spanned Elevation of the proposed lowest floor,including basement;in areas of shallow flooding (AO zones), the height of the proposed lowest floor, including Beam over-spanned Provide design data for all unaligned wall and floor bearing points basement,above the adjacent highest grade shall be identified(8106.1.3) Point loads not identified on beam data Electrical systems, equipment and components, and heating, ventilation, air conditioning and plumbing appliances,plumbing fixtures,duct systems,and Steel beam — must be stamped and signed by a Connecticut Professional other service equipment shall be located at or above the design flood elevation. Engineer LVL's—engineering data required ELECTRICAL INFORMATION I-joists—engineering data required Design loads not provided or insufficient / The provisions of Part VIII of the 2012 IRC or 2014 NFPA 70 National V Electric Code shall apply to installation of the electrical system and must be •ROOF FRAMING indicated on the application. Plans required showing rafters,beams and openings Plans required showing panel locations,GFCI,switches,lights and receptacle locations Bearing partitions not provided or indicated virService capacity is not indicated,underground or overhead Framing direction not indicated Panel location not identified Beam span&size not provided or insufficient Receptacle locations not identified or insufficient Rafter span,size&spacing not provided V GFCI receptacle locations not identified or insufficient Rafter's over-spanned Lights and switches not identified or insufficient Beam over-spanned Smoke alarms not identified or insufficient Provide design data for all unaligned wall and floor bearing points CO detector(s)not identified or insufficient(required on all habitable levels) Point loads not identified on beam data Electrical load calculations required Steel beam — must be stamped and signed by a Connecticut ProfessionalIfhirlpool tub/hydro message tub disconnect location not identified Engineer ✓ if 12.0 Lia it- Ci✓e-uif5 01Wat be Av'c-Ft(r Fu-tea', LVL's—engineering data required I-joists—engineering data required Valley rafter—engineering data required MECHANICAL INFORMATION Collar tie size,spacing&location not identified or insufficient Type of heating system not provided C I Roof trusses — Engineering data (signed and sealed by a Connecticut Plans required showing equipment locations,ductwork,etc. Professional Engineer) must be submitted and approved by the Building / Dryer vent routing not identified or insufficient Department prior to installation 1/ Heating,ventilation and air conditioning equipment locations not identified Roof truss data must be designed to ASCE 7-02 ✓ Heat loss/gain calculations required to be submitted Ridge beam supports not identified or insufficient • Heat loss/gain calculations do not match the information on the construction Hip/valley beam supports not identified or insufficient documents Rafter to beam connection detail not provided or insufficient Combustion air calculations required Winter design temperature is 7°F DECKS/PORCHES Constniction documents required ENERGY CODE REQUIREMENTS Dimensions required A permanent certificate shall be posted on or in the electric distribution panel. Framing direction not indicated / The certificate shall be completed by the builder or design professional.The Beam span&size not provided or insufficient V/ certificate shall list the predominant R-value of insulations installed in or on Joist span,size&spacing not provided ceiling/roof,walls,foundation(slab,basement walls,crawl space wall and/or Joist's over-spanned floor)and duct outside conditioned spaces.Along with other listings required by the code. Beam over-spanned Ledger—show attachment and flashing detail Access doors from condition spaces to unconditioned spaces(e.g.,attics and crawl spaces)shall be weather stripped and insulated to an equivalent to the Lateral connection devices required not shown or referenced on plans insulation around the surrounding surfaces. Post size or spacing not indicated Slab on grade floors with a floor less than 12"below grade shall be insulated. Height of deck above adjacent finished grade not provided New wood-burning fireplaces shall have gasketed doors and outside Connections not identified or insufficient combustion air. Plans do not match site plan Any nonconditioned space that is altered to become conditionedspace shall be required to be brought into compliance with the 2012 International Energy CHIMNEYS&FIREPLACES Conservation Code Clearances to combustibles not indicated ort insufficient Spaces undergoing a changes in occupancy that would result in an increase in Flue size not indicated or insufficient demand for either fossil or electric energy shall comply with the 2012 Exterior combustion air source not identified International Energy Conservation Code Plan required showing fireplace opening size and clearances to combustibles Flue sizes FUEL and GAS INFORMATION Manufactures data and installation instructions for metal fireplaces and/or LP-Gas tank size and location not identified on the plans wood stove required Trench detail not provided or insufficient Dimension height of chimney above the roof Piping diagram not submitted or insufficient Wood burning fireplaces shall have tight fitting dampers and outdoor Oil tank size and location not identified on the plans combustion air. PLUMBING SYSTEM INFORMATION TWO-FAMILY DWELLING UNIT SEPARATION(R302.3) No plans submitted or insufficient information Dwelling units in two-family dwelling shall be separated from each other by Building trap location not identified(inside or outside) wall and/or floor assemblies having not less than 1-hour fire-resistance rating Sewer location not identified when tested in accordance with ASTM E 119 or UL 263. Domestic water location not identified Manufacturers data for whirlpools,corner tubs&large tubs required TOWNHOUSE SEPARATION(R302.2) Water heater size,type,and location to be submitted Each townhouse shall be considered a separated building and shall be separated by fire-resistance-rated wall assemblies meeting the requirements of section R- 302.1 for exterior walls. Penetrations of wall or floor/ceiling assemblies required to be fire-resistance rated in accordance with section R302.2 or R302.3 shall be protected in accordance with this section. Comments: _17s Mere ���`.� f� e -C - �r f`i, s � e-i)e ) J ' Rebar ree,ti;,td ,' F not so; l davf,- i.s lace .1 .SRC' , Permit application reviewed by: Sa.---L71"4 Vernon D.Vesey II David .Jensen Building Official Deputy Building Official 9isvise19u(y 10,2017