Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
SFR Heating and A/C
Town of Montville Building Department Phone: 848-7166 310 Norwich New London Tpke Fax: 848-7231 Building / Trades Permit Permit Number M2001-89 Permit Date 6/19/01 Permit Type Mechanical Permit Code R5 Job Street# 51 Job Location PHEASANT RUN Map/Lot 028/005-042 Job Description Heating &Air Conditioning Owner Contractor D'Amato Bros. Viglione Heating & Cooling Address P. O. Box 3063 Address 259 Commerce Street City Milford State Ct. City East Haven State Ct. Zip 06460 Telephone 203-874-5992 Zip 06512 Telephone 203-467-8388 Lic/Reg Number 302380 Lic/Reg Type S1 Exp Date: 8/31/01 Use Group R4 _ _ Code 1995 CABO Type Construction 5B Building Value $0.00 Building Fee $0.00 Plumbing Value $0.00 Plumbing Fee $0.00 Mechanical Value $0.00 Mechanical Fee $0.00 Electrical Value $0.00 Electrical Fee $0.00 Other Value $0.00 Other Fee $0.00 Total Values $0.00 C/O Fee $0.00 Comments: Plan Review Fee $0.00 Paid on Building Permit State Ed Fee $0.00 Total Fees $0.00 Building Official's Signatur, , - - Date /Z..,0 I 0) '� It is the owners resp. - ,/i o schedule the following required inspections(minimum 24 hours notice required): Footings-prior to ••uring concrete ❑ Backfill -footing drains and waterproofing ❑ Fireplace Throat ❑ Concrete Slab, prior to pouring ❑ Fireplace Final ❑ Rough Framing ❑ Chimney -one flue above thimble ❑ Rough Electrical ❑ Firestopping/draftstopping ❑ Electrical Service ❑ Insulation ❑ Rough Plumbing and leak test ❑ Pool bonding ❑ Gas piping-pressure test and installation ❑ Final Inspection ❑ Rough HVAC ❑ Certificate of Occupancy-PRIOR to use or occupancy 1 Town of Montville Permit #,4 o f•- i9 Building Department 310 Norwich-New London Tpke. Tel. 848-7166 Uncasville, CT 06382 Fax. 848-7231 Application for Building or Trades Permit / Building Permit Trades Permit ❑✓New Construction []Accessory Structure ❑cPlum6ing 21ec(ianica( ❑Action ❑DemoCztion ❑Electrica1 ✓ .7feating ❑Alteration ❑Other Air Conditioning Gas Piping Job Location 51 ? ecnant PAn Job Description/Materials t-Lt nn 11ht y .1(13-fait Ui I cYa rrn a i r f ectii n _ J with adconckfion1r 3 Owner 'A(}o-t e('c-ther�j Mailing Address 0 • box 30693 City l''�(c1/4, State CT Zip Tel / SW/5994.9 Contractor V t ice- ea1V)( 'f'Cod I ailing Address ,,5q a/Y?( 1� ` ee- J City CPO+ 4-k-Nen State Zip Q(c(. Tel ,.;;�(;3"ft5RCf Contractor's License/Registration Type&Number 30,93%Q S I Exp. Date g /31 /cx0( New Home Construction Contractors: Have you entered into a contract with a consumer for the proposed new home? ❑ Yes ❑ No I hereby certify that the proposed work will conform to the Basic Building Code and all other codes as adopted by the State of Connecticut and the Town of Montville and further attest that the proposed work is authorized by the owner in fee and that I am authorized to make application for a permit for such work as described above. Owner/Agent Signature 1 _ t / / Date i"2 / a Construction Value Fee Building $ $ Plumbing $ $ Mechanical $ $ Electrical $ $ Other $ $ Certificate of Occupancy $ Plan Review Fee $ State Education $ Total $ $ 6 - -dE HTG & CLG, INC. P'ED COMMERCE DRIVE CLIENT: l HAVEN, CT 06512 DATE: 055/17/99 DAMA /17/9 RESIDENTIAL/LIGHT COMMERCIAL HVAC LOADS DESIGNER: STEVE VIGLIONE CLIENT INFORMATION: NAME : DAMATO BROS ADDRESS : CITY, STATE : MONTVILLE CONN TOTAL BUILDING LOADS : BLDG. LOAD AREA SEN. LAT. + SEN. . TOTAL DESCRIPTIONS QUAN LOSS GAIN GAIN GAIN 3-C WINDOW DBL PANE CLR GLS METL FR 176 10, 208 12-I WALL R-19 +1/2 "ASPHLT BRD (R-1 . 3) 1, 724 7, 586 0 4, 436 4, 436 0 2 , 239 2, 239 11-C DOOR METAL POLYSTYRENE CORE 16-G CEILING R-30 INSULATION 84 2 ,4 281 0 932 932 81 19-A FLOOR/ENCL CRAWL HARDWD NO INS 1, 872 23 , 363 0 1, 255 1, 250 0 0 0 SUBTOTALS FOR STRUCTURE: 4, 720 46, 596 0 8, 862 8, 862 PEOPLE • APPLIANCES 8 0 1, 840 2400 4, 240 DUCTWORK 0 0 0 1, 200 1, 200 0 , 417 0 733 733 INFILTRATION W.CFM: 199 . 7 S . CFM: 99 . 8 0 17, 572 2 , 784 2 , 196 4, 980 VENTILATION W.CFM: 74 . 9 S . CFM: 74 . 9 0 6, 589 2 , 088 1, 647 3 , 735 SENSIBLE GAIN TOTAL TEMP. SWING MULTIPLIER 17, 038 X 1 . 00 BUILDING LOAD TOTALS 77, 174 6, 712 17, 038 23 , 750 SUPPLY CFM AT 91 . 70 DEG HTG DT: 700 SQUARE FT. OF ROOM AREA: CFM PER SQUARE FOOT: 0 . 374 1, 872 SQUARE FOOT PER TON: 945 . 853 TOTAL HEATING REQUIRED WITH OUTSIDE AIR: 77 . 174 MBH TOTAL COOLING REQUIRED WITH OUTSIDE AIR: 1 . 979 TONS CALCULATIONS ARE BASED ON 7TH EDITION OF ACCA MANUAL J. ALL COMPUTED RESULTS ARE ESTIMATES AS BUILDING USE AND WEATHER MAY VARY. BE SURE TO SELECT A UNIT THAT MEETS BOTH SENSIBLE AND LATENT LOADS . • /* RESIDENTIAL -AND LIGHT COMMERCIAL HVAC LOADS BY ELITE SOFTWARE ******* _ONE HTG & CLG, INC. • EAST HAVEN, CT 06512 E 1872 SQ FT 05/17/99 *********************** ZONE 2 ROOM LOAD SUMMARY PAGE 2 # ************************* .M ROOM AREA HEATING 1O. DESCRIPTION (SF) BTUH o TOT CFM BTUH COOTOTG CFM 1 . WHOLE FIRST FL 1, 008 41, 304 58 . 5 536 8, 499 55 .2 386 2 . WHOLE SECOND FL 864 29, 281 41 . 5 380 6, 892 44 . 8 313 ;ONE SUBTOTAL 1, 872 70, 585 100 . 0 917 15, 391 100 . 0 700 { ENTILATION 6, 589 LATENT GAIN. 1, 647 6, 712 ONE TOTALS ` 77, 174 23 , 750 1 . 979 TONS • • • • ;7' ?'. W.- WEBB COMPANY RESIDENTIAL HEAT LOS 7GAIIT O.ALCULA IONS PREPARED BY FIRST CLASS MECH ?ROJECT # : 124721 BY FIRSTCLS ENTERED 02/25/99 BLD 1 . NAME :STERLING GAIN BTU: 26426 ?. LOCATION :MONTVILLE GAIN CMF: 881 3. HI DESIGN TMP: 91 8 .GRND TEMP 50 LOSS BTU: 41405 1. LO DESIGN TMP: -10 9.COOL AIR TMP: 50 LOSS CFM: 782 3. ROOM TEMP71 10.WARM AIR TMP: 120 BASEBRD' : 76 5. LEEWAY 10 TONNAGE : 2.2 7. # OF PEOPLE 4@ (00M # 1 OF 10 41 .WALL G DELTA 2( .2.ROOM NAME :ENTRY 42 .WALL L DELTA 8] 43. FLOOR G DELTA : 2( 44 . FLOOR L DELTA : 81 45.CEILNG G DLTA : ( 46.CEILNG L DLTA : 47 .BELW GRD DLTA : 21 3.EXT WALL LEN : 14 24 . FLOOR R-FACTOR: 19 35.MISC BTU GAIN : 4 .EXT WALL HGT : 8 25 .HEAT/CL BELOW : N 36.MISC BTU LOSS : 5.WALL R-FCTR 14 26.CEILING R-FCTR: 19 37 .BASEBD BTU/FT : 58C 6.WINDOW SQ FT : 0 27 .HEAT/CL ABOVE? : Y 38 .PEOPLE BTUS 40C 7.WINDOW GLASS : D 28 . SKY LGHT SQ FT: 0 : . 00 8.DOOR SQ FT 21 29 . SKY LGHT TYPE : D ***TOTALS FOR ROOM****** * 9.DOOR R-FCTR 2 30 .AIR CHGS/HOUR : . 50 * GAIN BTU: 531 0.N,NE,E, SE. . . : S 31 .EXTRA PEOPLE * GAIN CFM: 18 1 .WIN. SHADING : N 32 . LIGHTS (WATTS) : * LOSS BTU: 1959 2.% BELOW GRADE: 0 33 .KITCHEN(Y/N) N * LOSS CFM: 37 3. FLOOR SQ FT 40 34 .BATH (Y*N) N * BASEBRD' : 4 OOM # 2 OF 10 41 .WALL G DELTA 20 2 .ROOM NAME :BREAK/KITCHEN 42 .WALL L DELTA 81 43. FLOOR G DELTA : 20 44 . FLOOR L DELTA : 81 45.CEILNG G DLTA : 20 46.CEILNG L DLTA : 81 47 .BELW GRD DLTA : 21 3.EXT WALL LEN : 29 24 . FLOOR R-FACTOR: 19 35.MISC BTU GAIN : 4 .EXT WALL HGT : 8 25.HEAT/CL BELOW : N 36.MISC BTU LOSS : 5.WALL R-FCTR 14 26.CEILING R-FCTR: 19 37.BASEBD BTU/FT : 580 6.WINDOW SQ FT : 9 27 .HEAT/CL ABOVE?: N 38 .PEOPLE BTUS 400 7 .WINDOW GLASS : D 28 . SKY LGHT SQ FT: 0 : . 00 8.DOOR SQ FT 21 29. SKY LGHT TYPE : D ***TOTALS FOR ROOM******* 9.DOOR R-FCTR 2 30 .AIR CHGS/HOUR : . 50 * GAIN BTU: 3869 0.N, NE, E, SE. . . : S 31 .EXTRA PEOPLE * GAIN CFM: 129 1 .WIN. Si-iADING : N 32 . LIGHTS (WATTS) : * LOSS BTU: 5908 2 .% BELOW GRADE: 0 33.KITCHEN(Y/N) Y * LOSS CFM: 112 3. FLOOR SQ FT 204 34 .BATH (Y*N) N * BASEBRD' : 11 (HE[JROOM # 3 OF 10 41 .WALL G DELTA 2 .ROOM NAME : DINING 42 .WALL L DELTA 81 43 . FLOOR G DELTA : 20 44 . FLOOR L DELTA : 81 45.CEILNG G DLTA : 20 46.CEILNG L DLTA : 81 47 _RET.W C;Rf T)T.TA : 21 Lq . T w�'L HGT : b G �: S.HAT/CL BELOW : N 36 .MISC BTU LOSS : 1.5-..WALL R-FCTR 14 26 .CEILING R-FCTR: 19 37 .BASEBD BTU/FT : r 16.WINDOW SQ FT : 15 27.HEAT/CL ABOVE?: N 38 .PEOPLE BTUS 4 17.WINDOW GLASS : D 28 . SKY LGHT SQ FT: 0 : . 00 18.DOOR SQ FT 0 29.SKY LGHT TYPE : D ***TOTALS FOR ROOM***** 19.DOOR R-FCTR 2 30.AIR CHGS/HOUR : . 50 * GAIN BTU: 1992 ?O.N,NE, E, SE. . . : S 31 .EXTRA PEOPLE * GAIN CFM: 66 ?1.WIN. SHADING : N 32 .LIGHTS (WATTS) : * LOSS BTU: 3936 ?2.% BELOW GRADE: 0 33 .KITCHEN(Y/N) N * LOSS CFM: 74 ?3.FLOOR SQ FT 132 34 .BATH(Y*N) N * BASEBRD' : 7 LOOM # : 4 OF 10 41 .WALL G DELTA 12.ROOM NAME :LR 42.WALL L DELTA . 43. FLOOR G DELTA : 44 . FLOOR L DELTA : 45.CEILNG G DLTA : : 46.CEILNG L DLTA : 1 3.EXT WALL LEN 2347.BELW GRD DLTA : 24 . FLOOR R-FACTOR: 19 35.MISC BTU GAIN : 4 .EXT WALL HGT : 8 25.HEAT/CL BELOW : N 36.MISC BTU LOSS : L5.WALL R-FCTR 14 26.CEILING R-FCTR: 19 37 .BASEBD BTU/FT : 5 !6.WINDOW SQ FT : 30 27 .HEAT/CL ABOVE?: N 38. PEOPLE BTUS 4( :7.WINDOW GLASS : D 28 . SKY LGHT SQ FT: 0 : . 00 .8.DOOR SQ FT 0 29. SKY LGHT TYPE : D ***TOTALS FOR ROOM .9.DOOR R-FCTR 2 30.AIR CHGS/HOUR : . 50 * GAIN BTU: 3025 ?O.N,NE,E, SE. . . : S 31 .EXTRA PEOPLE * GAIN CFM: 101 ?1 .WIN. SHADING : N 32 .LIGHTS (WATTS) : * LOSS BTU: 4615 '.2 .% BELOW GRADE: 0 33.KITCHEN(Y/N) N * LOSS CFM: 87 ?3.FLOOR SQ FT 132 34 .BATH (Y*N) N * BASEBRD' : 8 ZOOM # 5 OF 10 41 .WALL G DELTA 2 _2.ROOM NAME : FAM RM 42 .WALL L DELTA 8 43. FLOOR G DELTA : 2 44 . FLOOR L DELTA : 8 45 .CEILNG G DLTA : 2 46.CEILNG L DLTA : 8 47 .BELW GRD DLTA : 2 3.EXT WALL LEN 32 24 . FLOOR R-FACTOR: 19 35.MISC BTU GAIN : 4 .EXT WALL HGT : 8 25.HEAT/CL BELOW : N 36.MISC BTU LOSS : 5.WALL R-FCTR 14 26.CEILING R-FCTR: 19 37 .BASEBD BTU/FT : 58 6.WINDOW SQ FT : 42 27 .HEAT/CL ABOVE?: N 38 .PEOPLE BTUS 40i 7.WINDOW GLASS : D 28 . SKY LGHT SQ FT: 0 : . 00 8.DOOR SQ FT 0 29. SKY LGHT TYPE : D ***TOTALS FOR ROOM******' 9.DOOR R-FCTR 2 30.AIR CHGS/HOUR : .50 * GAIN BTU: 4513 O.N,NE,E, SE. . . : S 31 .EXTRA PEOPLE 1 .WIN. SHADING : N 32 .LIGHTS (WATTS) : GAIN CFM: 150 * 2.% BELOW GRADE: LOSS BTU: 7323 0 33.KITCHEN(Y/N) N * LOSS CFM: 138 3. FLOOR SQ FT 240 34 .BATH (Y*N) : N BASEBRD' : 13 (HJ(JROOM # 6 OF 10 41 .WALL G DELTA 2.ROOM NAME :MAST BED 42 .WALL L DELTA 81 43. FLOOR G DELTA : C 44. FLOOR L DELTA : C 45.CEILNG G DLTA : 2C 46.CEILNG L DLTA : 81 47.BELW GRD DLTA : 3.EXT WALL LEN : 30 24 . FLOOR R-FACTOR: 19 35.MISC BTU GAIN : 21 LEXT WALL HGT : 8 25.HEAT/CL BELOW : Y 36.MISC BTU LOSS lJ.t.A uv l\ L aa♦ i s - .- --- -- _ L,6.WINDOW SQ FT : 30 27 .HEAT/CL ABOVE?: N 38 . PEOPLE BTUS 4 17.WINDOW GLASS : D 28 . SKY LGHT SQ FT: 0 : . O 18 .DOOR SQ FT 0 29 .SKY LGHT TYPE : D ***TOTALS FOR ROOM* **** 19.DOOR R-FCTR 2 30.AIR CHGS/HOUR : . 50 * GAIN BTU: 3321 20.N,NE,E, SE. . . : S 31 .EXTRA PEOPLE * GAIN CFM: 111 21 .WIN. SHADING : N 32 .LIGHTS (WATTS) : * LOSS BTU: 5374 22.% BELOW GRADE: 0 33 .KITCHEN(Y/N) N * LOSS CFM: 102 23. FLOOR SQ FT 224 34 .BATH(Y*N) N * BASEBRD' : 10 ROOM # 7 OF 10 41 .WALL G DELTA . 12.ROOM NAME :BED2 42 .WALL L DELTA . 43 . FLOOR G DELTA : 44 . FLOOR L DELTA : 45.CEILNG G DLTA : 46 .CEILNG L DLTA 47 .BELW GRD DLTA : 13.EXT WALL LEN : 24 24 .FLOOR R-FACTOR: 19 35.MISC BTU GAIN : 14 .EXT WALL HGT : 8 25.HEAT/CL BELOW : Y 36.MISC BTU LOSS : 15.WALL R-FCTR 14 26.CEILING R-FCTR: 19 37 .BASEBD BTU/FT : 5 16.WINDOW SQ FT : 30 27 .HEAT/CL ABOVE? : N 38 . PEOPLE BTUS 4 17.WINDOW GLASS : D 28.SKY LGHT SQ FT: 0 : . 00 18.DOOR SQ FT 0 29.SKY LGHT TYPE : D ***TOTALS FOR ROOM***** 19.DOOR R-FCTR 2 30.AIR CHGS/HOUR : . 50 * GAIN BTU: 2928 20.N,NE,E, SE. . . : S 31 .EXTRA PEOPLE * GAIN CFM: 98 21.WIN. SHADING : N 32 .LIGHTS (WATTS) : * LOSS BTU: 4169 22.% BELOW GRADE: 0 33 .KITCHEN(Y/N) N * LOSS CFM: 79 23. FLOOR SQ FT 143 34 .BATH (Y*N) N * BASEBRD' : 8 ROOM # 8 OF 10 41 .WALL G DELTA 12.ROOM NAME :BED3 42 .WALL L DELTA • 43 . FLOOR G DELTA : 44 . FLOOR L DELTA : 45.CEILNG G DLTA : 46.CEILNG L DLTA : 47 .BELW GRD DLTA : 13.EXT WALL LEN : 25 24 . FLOOR R-FACTOR: 19 35.MISC BTU GAIN : 14.EXT WALL HGT : 8 25.HEAT/CL BELOW : Y 36.MISC BTU LOSS : 15.WALL R-FCTR 14 26.CEILING R-FCTR: 19 37 .BASEBD BTU/FT : 5 16.WINDOW SQ FT : 30 27 .HEAT/CL ABOVE?: N 38 . PEOPLE BTUS 4 17 .WINDOW GLASS : D 28 . SKY LGHT SQ FT: 0 : . 00 18 .DOOR SQ FT 0 29. SKY LGHT TYPE : D ***TOTALS FOR ROOM***** 19.DOOR R-FCTR 2 30 .AIR CHGS/HOUR : . 50 * GAIN BTU: 2940 20.N,NE, E, SE. . . : S 31 .EXTRA PEOPLE * GAIN CFM: 98 21 .WIN. SHADING : N 32 .LIGHTS (WATTS) : * LOSS BTU: 4220 22 .% BELOW GRADE: 0 33 .KITCHEN(Y/N) N * LOSS CFM: 80 23.FLOOR SQ FT 143 34 .BATH(Y*N) N * BASEBRD' : 8 2[HD[JROOM # 9 OF 10 41 .WALL G DELTA 12 .ROOM NAME :MAST BATH 42 .WALL L DELTA . 43 . FLOOR G DELTA : 44 . FLOOR L DELTA : 45.CEILNG G DLTA : 46.CEILNG L DLTA : 47 .BELW GRD DLTA : 13.EXT WALL LEN : 15 24 . FLOOR R-FACTOR: 19 35.MISC BTU GAIN : 14.EXT WALL HGT : 8 25.HEAT/CL BELOW : Y 36.MISC BTU LOSS : 15.WALL R-FCTR 14 26.CEILING R-FCTR: 19 37 .BASEBD BTU/FT : 5 16.WINDOW SQ FT : 6 27 .HEAT/CL ABOVE? : N 38 . PEOPLE BTUS 4 18,,DOOR SQ FT 0 29.SKY LGHT TYPE : D ***TOTALS FOR ROOM***1 19.DOOR R-FCTR 2 30.AIR CHGS/HOUR : . 50 * GAIN BTU: 821 20.N,NE, E, SE. . . : S 31 .EXTRA PEOPLE * GAIN CFM: 27 21 .WIN. SHADING : N 32 .LIGHTS (WATTS) : * LOSS BTU: 1657 22.% BELOW GRADE: 0 33.KITCHEN (Y/N) N * LOSS CFM: 31 23.FLOOR SQ FT 56 34 .BATH(Y*N) N * BASEBRD' : 3 ROOM # : 10 OF 10 41 .WALL G DELTA 12 .ROOM NAME :MAIN BATH 42 .WALL L DELTA . 43. FLOOR G DELTA : 44 . FLOOR L DELTA : 45.CEILNG G DLTA : 46.CEILNG L DLTA : 47 .BELW GRD DLTA : 13.EXT WALL LEN : 17 24 .FLOOR R-FACTOR: 19 35.MISC BTU GAIN : 14 .EXT WALL HGT : 8 25.HEAT/CL BELOW : N 36.MISC BTU LOSS : 15.WALL R-FCTR 14 26.CEILING R-FCTR: 19 37 .BASEBD BTU/FT : 16.WINDOW SQ FT : 6 27 .HEAT/CL ABOVE? : Y 38 . PEOPLE BTUS 17.WINDOW GLASS : D 28 .SKY LGHT SQ FT: 0 : . 00 18 .DOOR SQ FT 0 29.SKY LGHT TYPE : D ***TOTALS FOR ROOM**** 19.DOOR R-FCTR 2 30.AIR CHGS/HOUR : . 50 * GAIN BTU: 886 20.N,NE,E, SE. . . : S 31 .EXTRA PEOPLE * GAIN CFM: 30 21 .WIN. SHADING : N 32 .LIGHTS (WATTS) : * LOSS BTU: 2244 22. % BELOW GRADE; 0 33.KITCHEN(Y/N) N " LOSS CFM: 42 23.FLOOR SQ FT 66 34 .BATH (Y*N) Y * BASEBRD' : 4