HomeMy WebLinkAboutGas Test Field Inspection Notice
Town of Montville
Building Department
April 19, 2007
Address: 44 Pheasant Run
Job Description: Gas lines &tank
Permit Number(s): M2005-0224 Permit Date:
INSPECTION Not Approved Approval
Date: Deficiencies Special Conditions Date
Gas Line Test • • 10/19/01 JS
Certificate of • • 10/19/01 JS
approval
Rev.Date: 10/18/05 Page 1 of 1
0 Town of Montville 0
Building Department
Date JD / /g / D 1 Field Inspection Notice Permit #
y
Job Location 9 /lea.50 A)21 )6 {441
, 71yipproved Type of Inspection (t 5 -j P 54
Not Approved - Please call for re-inspection when the following corrections have been completed:
// 1'51 ---
I
I
I
air-
Building Official
Town of Montville
Building Department
RESIDENTIAL GAS INSPECTION CHECKLIST
CONTROL DEVICES TANK INSTALLATION
❑ Automatic appliances shall be equipped with a ❑ Underground containers minimum 10 ft from
listed and labeled device or devices that will shut basements, structures which extend below grade
off the fuel supply to the main burner in the event level or adjoining property lines(2611.4)
of pilot or ignition failure(1308.1) ❑ DOT & ASME containers shall have a readily
visible the firm name and emergency telephone
ROUGH-IN numbers(NFPA 58;2-2.6.6)
❑ Pressure test (air, CO2, or nitrogen) 10 psig for ❑ ASME containers shall have the firm name and
minimum 15 minutes OR 6" mercury measured telephone numbers a minimum of V2 inch in
with monometer or slope gage(2603.3.1) height(NFPA 58; 2-2.6.6(a))
❑ Welded piping and piping for appliances in ❑ Tank protected from vehicular traffic (NFPA 58;
excess of 14"wc shall be tested at 60 psig for 3-2.4.1(c))
minimum 30 minutes(2603.3.1)
❑ Shut-off valve to be located within 6 ft of
appliance(2606.3)
❑ Sediment trap(2608.2.2)
❑ Meter located min. 3 ft from sources of ignition
when installed indoors(2604.1)
GAS PIPING INSTALLATION
❑ Min. 12" burial depth for metallic piping below
grade(2608.1.1)
❑ Min. 18" burial depth for plastic piping below
grade(2608.1.1)
❑ Protected against corrosion(2608.1.2)
❑ Min. #18 AWG yellow insulated copper tracer
wire conductor shall be installed adjacent to
underground nonmetallic gas piping and shall be
accessible(2608.1.6)
❑ Hanger spacing-tubing max.6 ft—rigid up to'/,"
max. 10 ft—rigid 1"and up max. 12 ft(2608.2.6)
❑ Yellow label "GAS" @ 5 ft intervals were
exposed piping except for black steel (2608.8)
❑ Metallic gas piping to be bonded to the grounding
electrode(2608.9)
❑ Above ground piping to be protected from
physical damage(NFPA 58;3-2.8.7)
LPG TANK LOCATIONS
MINIMUM HORIZONTAL DISTANCE FROM:
Tank to Buildings, Pressure-relief
Pressure-relief Fill Connection
CONTAINER TYPE SIZE(Water capacity �' Device to and Gage Vent
Structures or Device to
Property Lines Building Openings Sources of to Sources of
(fes) ( ) Ignition or Vents Ignition or Vcnts
(feet) (feet)
DOT Exchanged Less than 125 None 3 5 —
DOT Site Filled Less than 125 None 3 5 10
ASME Less than 125 None 5 5 10
ASME 125 to 500 10 — — 10