HomeMy WebLinkAboutGas Test Field Inspection Notice Town of Montville Building Department April 19, 2007 Address: 44 Pheasant Run Job Description: Gas lines &tank Permit Number(s): M2005-0224 Permit Date: INSPECTION Not Approved Approval Date: Deficiencies Special Conditions Date Gas Line Test • • 10/19/01 JS Certificate of • • 10/19/01 JS approval Rev.Date: 10/18/05 Page 1 of 1 0 Town of Montville 0 Building Department Date JD / /g / D 1 Field Inspection Notice Permit # y Job Location 9 /lea.50 A)21 )6 {441 , 71yipproved Type of Inspection (t 5 -j P 54 Not Approved - Please call for re-inspection when the following corrections have been completed: // 1'51 --- I I I air- Building Official Town of Montville Building Department RESIDENTIAL GAS INSPECTION CHECKLIST CONTROL DEVICES TANK INSTALLATION ❑ Automatic appliances shall be equipped with a ❑ Underground containers minimum 10 ft from listed and labeled device or devices that will shut basements, structures which extend below grade off the fuel supply to the main burner in the event level or adjoining property lines(2611.4) of pilot or ignition failure(1308.1) ❑ DOT & ASME containers shall have a readily visible the firm name and emergency telephone ROUGH-IN numbers(NFPA 58;2-2.6.6) ❑ Pressure test (air, CO2, or nitrogen) 10 psig for ❑ ASME containers shall have the firm name and minimum 15 minutes OR 6" mercury measured telephone numbers a minimum of V2 inch in with monometer or slope gage(2603.3.1) height(NFPA 58; 2-2.6.6(a)) ❑ Welded piping and piping for appliances in ❑ Tank protected from vehicular traffic (NFPA 58; excess of 14"wc shall be tested at 60 psig for 3-2.4.1(c)) minimum 30 minutes(2603.3.1) ❑ Shut-off valve to be located within 6 ft of appliance(2606.3) ❑ Sediment trap(2608.2.2) ❑ Meter located min. 3 ft from sources of ignition when installed indoors(2604.1) GAS PIPING INSTALLATION ❑ Min. 12" burial depth for metallic piping below grade(2608.1.1) ❑ Min. 18" burial depth for plastic piping below grade(2608.1.1) ❑ Protected against corrosion(2608.1.2) ❑ Min. #18 AWG yellow insulated copper tracer wire conductor shall be installed adjacent to underground nonmetallic gas piping and shall be accessible(2608.1.6) ❑ Hanger spacing-tubing max.6 ft—rigid up to'/," max. 10 ft—rigid 1"and up max. 12 ft(2608.2.6) ❑ Yellow label "GAS" @ 5 ft intervals were exposed piping except for black steel (2608.8) ❑ Metallic gas piping to be bonded to the grounding electrode(2608.9) ❑ Above ground piping to be protected from physical damage(NFPA 58;3-2.8.7) LPG TANK LOCATIONS MINIMUM HORIZONTAL DISTANCE FROM: Tank to Buildings, Pressure-relief Pressure-relief Fill Connection CONTAINER TYPE SIZE(Water capacity �' Device to and Gage Vent Structures or Device to Property Lines Building Openings Sources of to Sources of (fes) ( ) Ignition or Vents Ignition or Vcnts (feet) (feet) DOT Exchanged Less than 125 None 3 5 — DOT Site Filled Less than 125 None 3 5 10 ASME Less than 125 None 5 5 10 ASME 125 to 500 10 — — 10