HomeMy WebLinkAboutSFR Heating and A/C Town of Montville
Building Department
Phone: 848-7166 310 Norwich New London Tpke Fax: 848-7231
Building /Trades Permit
Permit Number H2O00-113 Permit Date 8/25/00 Permit Type Heating Permit Code R5
Job Street# 37 Job Location Pheasant Run Map/Block-Lot 028/005-029
Job Description heating with A/C for new house
Owner D'amato Bros. Mailing Address P.O. Box 3063
City Milford State Ct. Zip 06460 Telephone 203-874-5992
Contractor Viglione H &C *Mailing Address 259 Commerce Street
*City East Haven *State Ct. *Zip 06512 *Telephone 203-467-8388
Lic/Reg Number 302380 Lic/Reg Type S1 Expiration Date 8/31/00
Use Group R4 Size Type Construction 5B
Building Value $0.00 Building Fee $0.00
Plumbing Value $0.00 Plumbing Fee $0.00
Heating Value $0.00 Heating Fee $0.00
Electrical Value Electrical Fee $0.00
NC Value $0.00 A/C Fee $0.00
Other Value $0.00 Other Fee $0.00
Total Values $0.00 State Ed Fee $0.00
C/O Fee $0.00
paid on building permit
Plan Review Fee $0.00
Total Fees $0.00
Building Official's Signatur• / / Date OC-)
Required Inspection
❑ Footings-Prior to pouring concrete v Rough Heating and Air Conditioning
O Footing Drains/Waterproofing -Prior to backfill ❑ Chimney -One flue above thimble
• Framing ❑ Fireplace-Throat
• Rough Electrical
❑ Fireplace- Final
L. Electrical Service ❑ Firestopping/Draftstopping
❑ Rough Plumbing -Leak test required ❑ Insulation
❑ Pool Bonding and Electric
141 Final Inspection for Certificate of Occupancy-PRIOR to Use or Occupancy
400 Town of Montville
led
Building Department
310 Norwich-New London Tpke.
Uncasville, Ct. 06382
Tel. 848-7166 Fax 848-7231
Application for Building or Trades Permit
Owner -Di Awa "brothers Mailing Address 0. Px 6(D3
City _ riMiO rd - State el Zip 06%0 Tel. 3- 0 1 t- Scria
Job Location ,W T r�" Run Map/Block-Lot a cQ g / o - p q
Contractor Vc J
)Q� jp�(� p� t ) Mailing Address o25q Commerce, St
City Go�}'--14a\(en State Crr Zip O(QQjR Tel. 3 - 0- $33e
Type of Permit
❑ New Single Family ❑ New Two Family ❑ Addition ❑ Commercial ❑ Industrial
❑ Alteration ❑ Garage ❑ Carport ❑ Shed
❑ Roofing
❑ Air Conditioning ❑ Plumbing Heating ❑ Electrical ❑ Gas
❑ Retaining Wall ❑ Deck ❑ Pool ❑ Patio ❑ Porch
Demolition ❑ Siding ❑ Windows ❑ Fireplace ❑ Chimney
JobDescription/Materials F q- I. (bl LOa.(m Cur I K a*i, 9 4- cd C.
::
Size Type of Heat (maim a,r- Use d upe t `‘ nq
I hereby certify that the proposed work will conform to the Basic Building Code and all other codes as adopted
by the State of Connecticut and the Town of Montville and further attest that the proposed work is authorized
by the owner in fee and that I am authorized to make application for a permit for such work as described above.
New Home Construction Contractors: Have you entered into a contract with the consumer for the proposed
work ? __ Yes ❑ No
-
Owner/Agent Signatur ,/ v Date P / 2 /
Contractors License/Registration Type &Number S I 580 Exp.Date 8/3 I /coo[
Construction Value Fee
Building $ $
Plumbing $ $
Heating $ $ °) ,
Electrical $ $ 11
Air Conditioning $ $
Other $ $
Certificate of Occupancy $
Plan Review Fee $
State Education Fee $ �(
Total $ $ 1V
a
i AE HTG & CLG, IN PROJECT: G• c ' 6'"5Q-r-r----
COMMERCE DRIVE CLIENT: DAMATO BROS
i HAVEN, CT 06512 DATE: 05/17/99
{ESIDENTIAL/LIGHT COMMERCIAL HVAC LOADS DESIGNER: STEVE VIGLIONE
CLIENT INFORMATION:
NAME: fAMATO BROS
' ADDRESS :
CITY, STATE : MONTVILLE CONN
TOTAL BUILDING LOADS :
BLDG. LOAD AREA SEN. LAT. + SEN. = TOTAL
DESCRIPTIONS QUAN LOSS GAIN GAIN GAIN
3-C WINDOW DBL PANE CLR GLS METL FR 156 9, 048 0 4, 125 4, 125
12-I WALL R-19 +1/2"ASPHLT BRD (R-1 . 3) 1, 573 6, 922 0 2, 042 2, 042
11-C DOOR METAL POLYSTYRENE CORE 63 2, 369 0 699 699
16-G CEILING R-30 INSULATION 768 2, 028 0 1, 115 1, 115
19-A FLOOR/ENCL CRAWL HARDWD NO INS 1, 536 19, 170 0 0 0
SUBTOTALS FOR STRUCTURE : 4, 096 39, 537 0 7, 981 7, 981
•
PEOPLE 8 0 1, 840 2 , 400 4, 240
APPLIANCES 0 0 0 1, 200 1, 200
DUCTWORK 0 5, 396 0 670 670
INFILTRATION W.CFM: 163 . 8 S . CFM: 81 . 9 0 14, 418 2 , 284 1, 802 4, 086
VENTILATION 4'.CFM: 61 .4 S .CFM: 61 .4. 0 5, 407 1, 713 1, 352 3 , 065
SENSIBLE GAIN TOTAL • 15, 405
TEMP. SWING MULTIPLIER X 1 . 00
BUILDING LOAD TOTALS 64, 758 5 , 837 15, 405 21, 242
LOAD SUMMARY FOR ZONE #1
SUPPLY CFM AT 91 . 20 DEG HTG DT: 328 CFM PER SQUARE FOOT: 0 . 427
SQUARE FT. OF ROOM AREA: 768 SQUARE FOOT PER TON: 821 . 976
TOTAL HEATING REQUIRED WITH OUTSIDE AIR: 35 . 615 MBH
TOTAL COOLING REQUIRED WITH OUTSIDE AIR: 0 . 934 TONS
LOAD SUMMARY FOR ZONE #2
SUPPLY CFM AT 70 DEG HTG DT: 343 CFM PER SQUARE FOOT: 0 .447
SQUARE FT. OF ROOM AREA: 768 SQUARE FOOT PER TON: 919 . 027
TOTAL HEATING REQUIRED WITH OUTSIDE AIR: 29 . 142 MBH
TOTAL COOLING REQUIRED WITH OUTSIDE AIR: 0 . 836 TONS
I\
.1-
*3
�
! "* RESIDENTIALAND L T &MMERCTAL HVAC LOADS ELITE SOFTWARE *******
f• f
- SONE HTG & CLG, INC. EAST HAVEN, CT 06512
,BREL 1536 SQ FT 05/17/99 PAGE 2
*********************** BUILDING LOADS (CONTINUED) *************************
TOTAL BUILDING LOAD SUMMARY
SUPPLY CFM AT 80.40 DEG HTG DT: 671 CFM PER SQUARE FOOT: 0 .437
SQUARE FT. OF ROOM AREA: 1, 536% SQUARE FOOT PER TON: 867 . 715
TOTAL HEATING REQUIRED WITH OUTSIDE AIR: 64 . 758 MBH
TOTAL COOLING REQUIRED WITH OUTSIDE AIR: 1 . 770 TONS
CALCULATIONS ARE BASED ON 7TH EDITION OF ACCA MANUAL J.
ALL COMPUTED RESULTS ARE ESTIMATES AS BUILDING USE AND WEATHER MAY VARY.
BE SURE TO- SELECT A UNIT THAT MEETS BOTH SENSIBLE AND LATENT LOADS .
4:'
' x* RESIDENTIAL AND LILer COMMERCT- L HVAC LOADS BY ELITE SOFTWARE *******
-ONE HTG & CLG, INC. EAST HAVEN, CT 06512
BREL 1536 SQ FT 05/17/99 PAGE 3
*********************** ZONE # 1 ROOM LOAD SUMMARY *************************
• . -
•
:M ROOM AREA HEATING COOLING
10. DESCRIPTION (SF) BTUH o TOT CFM BTUH . TOT CFM
1 . WHOLE FIRST FL 768 32, 912 100 . 0 374 7, 217 100 . 0 ' 328
SONE SUBTOTAL 768 32 , 912 100 . 0 374 7, 217 100 . 0 328
IENTILATION 2 , 703 676
JATENT GAIN 3 , 319
LONE TOTALS, 35, 615 11, 212 0 . 934 TONS
k******* RESIDENTIAL AND LIGHT COMMERCIAL HVAC LOADS BY ELITE SOFTWARE *******
VIGLIONE HTG & CLG, INC . EAST HAVEN, CT 06512
GAMBREL 1536 SQ FT 05/17/99 PAGE 4
************************* ZONE # 2 ROOM LOAD SUMMARY *************************
RM ROOM AREA HEATING COOLING
NO. DESCRIPTION (SF) BTUH o TOT CFM BTUH TOT CFM
2 . WHOLE SECOND FL 768 26, 439 100 . 0 343 6, 836 100 . 0 343
ZONE SUBTOTAL 768 26 , 439 100 . 0 343 6, 836 1,60 . 0 343
VENTILATION 2 , 703 676
LATENT GAIN 2 , 516
ZONE TOTALS 29, 142. 10, 028 0 . 836 TONS
.