Loading...
HomeMy WebLinkAboutSFR Heating and A/C Town of Montville Building Department Phone: 848-7166 310 Norwich New London Tpke Fax: 848-7231 Building /Trades Permit Permit Number H2O00-113 Permit Date 8/25/00 Permit Type Heating Permit Code R5 Job Street# 37 Job Location Pheasant Run Map/Block-Lot 028/005-029 Job Description heating with A/C for new house Owner D'amato Bros. Mailing Address P.O. Box 3063 City Milford State Ct. Zip 06460 Telephone 203-874-5992 Contractor Viglione H &C *Mailing Address 259 Commerce Street *City East Haven *State Ct. *Zip 06512 *Telephone 203-467-8388 Lic/Reg Number 302380 Lic/Reg Type S1 Expiration Date 8/31/00 Use Group R4 Size Type Construction 5B Building Value $0.00 Building Fee $0.00 Plumbing Value $0.00 Plumbing Fee $0.00 Heating Value $0.00 Heating Fee $0.00 Electrical Value Electrical Fee $0.00 NC Value $0.00 A/C Fee $0.00 Other Value $0.00 Other Fee $0.00 Total Values $0.00 State Ed Fee $0.00 C/O Fee $0.00 paid on building permit Plan Review Fee $0.00 Total Fees $0.00 Building Official's Signatur• / / Date OC-) Required Inspection ❑ Footings-Prior to pouring concrete v Rough Heating and Air Conditioning O Footing Drains/Waterproofing -Prior to backfill ❑ Chimney -One flue above thimble • Framing ❑ Fireplace-Throat • Rough Electrical ❑ Fireplace- Final L. Electrical Service ❑ Firestopping/Draftstopping ❑ Rough Plumbing -Leak test required ❑ Insulation ❑ Pool Bonding and Electric 141 Final Inspection for Certificate of Occupancy-PRIOR to Use or Occupancy 400 Town of Montville led Building Department 310 Norwich-New London Tpke. Uncasville, Ct. 06382 Tel. 848-7166 Fax 848-7231 Application for Building or Trades Permit Owner -Di Awa "brothers Mailing Address 0. Px 6(D3 City _ riMiO rd - State el Zip 06%0 Tel. 3- 0 1 t- Scria Job Location ,W T r�" Run Map/Block-Lot a cQ g / o - p q Contractor Vc J )Q� jp�(� p� t ) Mailing Address o25q Commerce, St City Go�}'--14a\(en State Crr Zip O(QQjR Tel. 3 - 0- $33e Type of Permit ❑ New Single Family ❑ New Two Family ❑ Addition ❑ Commercial ❑ Industrial ❑ Alteration ❑ Garage ❑ Carport ❑ Shed ❑ Roofing ❑ Air Conditioning ❑ Plumbing Heating ❑ Electrical ❑ Gas ❑ Retaining Wall ❑ Deck ❑ Pool ❑ Patio ❑ Porch Demolition ❑ Siding ❑ Windows ❑ Fireplace ❑ Chimney JobDescription/Materials F q- I. (bl LOa.(m Cur I K a*i, 9 4- cd C. :: Size Type of Heat (maim a,r- Use d upe t `‘ nq I hereby certify that the proposed work will conform to the Basic Building Code and all other codes as adopted by the State of Connecticut and the Town of Montville and further attest that the proposed work is authorized by the owner in fee and that I am authorized to make application for a permit for such work as described above. New Home Construction Contractors: Have you entered into a contract with the consumer for the proposed work ? __ Yes ❑ No - Owner/Agent Signatur ,/ v Date P / 2 / Contractors License/Registration Type &Number S I 580 Exp.Date 8/3 I /coo[ Construction Value Fee Building $ $ Plumbing $ $ Heating $ $ °) , Electrical $ $ 11 Air Conditioning $ $ Other $ $ Certificate of Occupancy $ Plan Review Fee $ State Education Fee $ �( Total $ $ 1V a i AE HTG & CLG, IN PROJECT: G• c ' 6'"5Q-r-r---- COMMERCE DRIVE CLIENT: DAMATO BROS i HAVEN, CT 06512 DATE: 05/17/99 {ESIDENTIAL/LIGHT COMMERCIAL HVAC LOADS DESIGNER: STEVE VIGLIONE CLIENT INFORMATION: NAME: fAMATO BROS ' ADDRESS : CITY, STATE : MONTVILLE CONN TOTAL BUILDING LOADS : BLDG. LOAD AREA SEN. LAT. + SEN. = TOTAL DESCRIPTIONS QUAN LOSS GAIN GAIN GAIN 3-C WINDOW DBL PANE CLR GLS METL FR 156 9, 048 0 4, 125 4, 125 12-I WALL R-19 +1/2"ASPHLT BRD (R-1 . 3) 1, 573 6, 922 0 2, 042 2, 042 11-C DOOR METAL POLYSTYRENE CORE 63 2, 369 0 699 699 16-G CEILING R-30 INSULATION 768 2, 028 0 1, 115 1, 115 19-A FLOOR/ENCL CRAWL HARDWD NO INS 1, 536 19, 170 0 0 0 SUBTOTALS FOR STRUCTURE : 4, 096 39, 537 0 7, 981 7, 981 • PEOPLE 8 0 1, 840 2 , 400 4, 240 APPLIANCES 0 0 0 1, 200 1, 200 DUCTWORK 0 5, 396 0 670 670 INFILTRATION W.CFM: 163 . 8 S . CFM: 81 . 9 0 14, 418 2 , 284 1, 802 4, 086 VENTILATION 4'.CFM: 61 .4 S .CFM: 61 .4. 0 5, 407 1, 713 1, 352 3 , 065 SENSIBLE GAIN TOTAL • 15, 405 TEMP. SWING MULTIPLIER X 1 . 00 BUILDING LOAD TOTALS 64, 758 5 , 837 15, 405 21, 242 LOAD SUMMARY FOR ZONE #1 SUPPLY CFM AT 91 . 20 DEG HTG DT: 328 CFM PER SQUARE FOOT: 0 . 427 SQUARE FT. OF ROOM AREA: 768 SQUARE FOOT PER TON: 821 . 976 TOTAL HEATING REQUIRED WITH OUTSIDE AIR: 35 . 615 MBH TOTAL COOLING REQUIRED WITH OUTSIDE AIR: 0 . 934 TONS LOAD SUMMARY FOR ZONE #2 SUPPLY CFM AT 70 DEG HTG DT: 343 CFM PER SQUARE FOOT: 0 .447 SQUARE FT. OF ROOM AREA: 768 SQUARE FOOT PER TON: 919 . 027 TOTAL HEATING REQUIRED WITH OUTSIDE AIR: 29 . 142 MBH TOTAL COOLING REQUIRED WITH OUTSIDE AIR: 0 . 836 TONS I\ .1- *3 � ! "* RESIDENTIALAND L T &MMERCTAL HVAC LOADS ELITE SOFTWARE ******* f• f - SONE HTG & CLG, INC. EAST HAVEN, CT 06512 ,BREL 1536 SQ FT 05/17/99 PAGE 2 *********************** BUILDING LOADS (CONTINUED) ************************* TOTAL BUILDING LOAD SUMMARY SUPPLY CFM AT 80.40 DEG HTG DT: 671 CFM PER SQUARE FOOT: 0 .437 SQUARE FT. OF ROOM AREA: 1, 536% SQUARE FOOT PER TON: 867 . 715 TOTAL HEATING REQUIRED WITH OUTSIDE AIR: 64 . 758 MBH TOTAL COOLING REQUIRED WITH OUTSIDE AIR: 1 . 770 TONS CALCULATIONS ARE BASED ON 7TH EDITION OF ACCA MANUAL J. ALL COMPUTED RESULTS ARE ESTIMATES AS BUILDING USE AND WEATHER MAY VARY. BE SURE TO- SELECT A UNIT THAT MEETS BOTH SENSIBLE AND LATENT LOADS . 4:' ' x* RESIDENTIAL AND LILer COMMERCT- L HVAC LOADS BY ELITE SOFTWARE ******* -ONE HTG & CLG, INC. EAST HAVEN, CT 06512 BREL 1536 SQ FT 05/17/99 PAGE 3 *********************** ZONE # 1 ROOM LOAD SUMMARY ************************* • . - • :M ROOM AREA HEATING COOLING 10. DESCRIPTION (SF) BTUH o TOT CFM BTUH . TOT CFM 1 . WHOLE FIRST FL 768 32, 912 100 . 0 374 7, 217 100 . 0 ' 328 SONE SUBTOTAL 768 32 , 912 100 . 0 374 7, 217 100 . 0 328 IENTILATION 2 , 703 676 JATENT GAIN 3 , 319 LONE TOTALS, 35, 615 11, 212 0 . 934 TONS k******* RESIDENTIAL AND LIGHT COMMERCIAL HVAC LOADS BY ELITE SOFTWARE ******* VIGLIONE HTG & CLG, INC . EAST HAVEN, CT 06512 GAMBREL 1536 SQ FT 05/17/99 PAGE 4 ************************* ZONE # 2 ROOM LOAD SUMMARY ************************* RM ROOM AREA HEATING COOLING NO. DESCRIPTION (SF) BTUH o TOT CFM BTUH TOT CFM 2 . WHOLE SECOND FL 768 26, 439 100 . 0 343 6, 836 100 . 0 343 ZONE SUBTOTAL 768 26 , 439 100 . 0 343 6, 836 1,60 . 0 343 VENTILATION 2 , 703 676 LATENT GAIN 2 , 516 ZONE TOTALS 29, 142. 10, 028 0 . 836 TONS .