HomeMy WebLinkAboutRoof Mounted Solar System 2015 Field Inspection Notice Town of Montville Building Department 860-848-3030 Ext.382 Address: 25 Pheasant Run Job Description: Install a 10.4kW Roof Mounted Solar System Permit Number(s) B2015-0575,E2015-0362 Permit Date: December 24,2015 Not Approved Approval INSPECTION Date: Comments Special Date Conditions • Roof reinforcement N/A • • 2/22/16 DJ Roof mounts • 2/22/16 DJ Inverter • 2/22/16 DJ Electric • • 2/22/16 DJ Grounding • • 2/22/16 DJ Panel labeling Conduit 2/22/16 DJ • Final inspection for • I ' 2/22/16 DJ I certificate of approval I **,NOTE** After one re-inspection additional inspection fees payable prior to re-inspection,are as follows: Residential inspections(except SFR C/O& SFR Additions C/O)-S 10.00 SFR and Additions C/O re-inspections -$10.00 Commercial re-inspections(except Certificate of Occupancy- $25.00 Commercial Certificate of Occupancy- $50.00 Page lofl Rev.Date: 1/18/06 Page 2 of 2 Customer Type Residential Inspector Remark 02/22/2016- DAVID JENSEN Approved Request Note: If the work request is canceled, please contact the Clearing Desk toll-free at 1-888-544-4826(1-888-LIGHTCO) UnApprove aJ Fail L1 Add Remarks https://www.eversource.com/c1p/wms/requestdetail.aspx?cd _wr=2653110&st rgmt=APPROVED&a=1&nl=insptrkrgst 2/22/2016 TOWN OF MONTVILLE Building Department 310 NORWICH-NEW LONDON TURNPIKE UNCASVILLE, CT 06382-2599 TEL. (860)848-3030 X382 FAX. (860) 848-7231 BUILDING PERMIT Permit Number: 132015-0575 Date: 24-Dec-15 Map/Lot: 028/005-028 Owner ID: 5465000 Project Location: 25 PHEASANT RUN Unit: Job Description: Install a 10.4kW Roof Mounted Solar System Tenant Name N/A Owner Nam Linda R Kabelis Careof: 25 Pheasant Run Telephone: (860)334-5291 Oakdale S.L 06370- Telephone: (203)701-3724 Applicant Name Marisa Montemurro Lic/Reg Type HIC DBA: Trinity Solar 635520 Lic/Reg N 611 West Johnson Avenue Exp Date: 30-Nov-15 Cheshire _`_ CT _ 06410- _ Permit Fees Construction Information Construction Value Building Value: $2,643.00 Use Group: IRC Building Fee: $36.00 Code: 2005 State Building Code Plumbing Fee: $0.00 Plumbing Value: $0.00 Mechanical Fe $0.00 $0.00 Mechanical Valu � Electrical Value: $35,109.00 Construction Type IRC Electrical Fee: 5432.00 Permit Code: R4 Penalty Fee: $0.00 Total Value: $37,752.00 Comment C of 0 Fee: $0.00 Plan Review FeS10 _ _ State Ed Fee: __$9.82 Total Fee Paid: $477.82 It shall be the owners repsonsibility to schedule the following inspections a minimum of 2 business days in advance: Field set of approved construction documents shall be available onsite during all inspections. BUILDING PERMIT INSPECTIONS PLUMBING,MECHANICAL,ELECTRICAL PERMIT INSPECTIONS ❑ Footing-Prior to pouring concrete ❑ R Plumbing and leak test R Electrical ❑ Deck Piers ❑ Backfill-Footing drains and waterproofing ❑ Elec Trench-with conduit installed CI Concrete Pool Bonding Concrete Slab-Prior to pouring concrete CRS No: 0 CI Anchor Bolts-with sill plate and prior to floor frami LI Electrical Service ❑ R HVAC (1Framing ❑ Gas Piping and leak test ❑ Masonry Fireplace Throat or Chimney Thimble INSPECTION REQUIRED UPON COMPLETION (11 Fireblocking Draftstopping - ❑ Insulation L.T. Certificate of Approval ❑,C:-rtifi9at -6f Occupancy 7 ' <=::: -------__ Building Official's Approval: - � . Town of Montville Building Department 310 Norwich-New London Tpke. Tel.860448-3030, Ext 382 Uncasville,CT 06382 Fax.860-848-7231. RESIDENTIAL PERMIT APPLICATION FORM Permit No.: Type of Work Occupancy Type Permit Type o New Construction LI Single Family Cj BuRding ❑Addition ❑Two-Family LI Plumbing o Alteration ❑Townhouse ©Mechanical 0 Accessory Structure ar.Eleelrical CRS#: Job Address: 25 Ph j c ev— R •q, • (Number) (Street) (Unit) Job Description: RIJO Oul ed cSo 0.C' ' s 16,4 Kw Lib PotrvelS Owner: Linda k.beL Address: 25 Pher,.Sc rl R�y�. city: _ O a(-d4(-e_ State: CT Zip Code: -7 o Telephone: S,DO—334- —52-9 1 Contractor: -Tr►nI — ViC-ha >V _ • mc,l, DBA: Address: (D U W e-S t (3O1r1SQ✓1 Av City: e_S W re. State: C t Zip Code: 0(01-11 C) Telephone: ZO3-70►3724 License Type: a 1 License No.:0 124 6 S Le_Expiration Date: q I hereby certify that the proposed work will confomt to the State Building Code and all other codes as adopted by the State of Connecticut and the Town of Montville and further attest that the proposed work is authorized by the owner in fee and that i am authorized to make application for a permit for such work as described above. By checking this box, I will follow the requirements of the 2005 NEC as the alternative compliance per section E3301.2.1 of the Residential Code, instead of the electrical requirements In chapters 33 through 42 of the Residential Code. Owner/Agent Signature: � � Date: 12 I Li Construction Value Permit Fees Building Value: 01.0'4 J. _ Building Fee: Plumbing Value: Plumbing Fee: Mechanical Value: Mechanical Fee: Electrical Value: 3.5 ley. Electrical Fee: Total Value: Penalty Fee: C of 0 Fee: Plan Review Foe: State Ed Fee; Total Fee: Revue.•fOrcembcr34 2005 energize M Permit# [For Jurisdiction Use]: f5c-4 .45-bc-,-75 CONNECTICUT £ao�-tea Connecticut Standardized Solar Photovoltaic (PV) Permit Application Date: 1 2- 1 5 ` I S Property Type:(Residential(R) ['Commercial( (C) El Other(specify): General Description of Solar PV Array: ROCY mO1.Ul I-Pd 1 d par)e System Size(kW DC): 10. t KyV Property Owner: L'1 n d q Kab e A i Street Address: 25 Phf'aLan+ Ri ty- Parcel ID#: Town: Oak.C1 Q I f' C j State: Zip: Phone: gb0--NX1-1 - 2 q 1 Cell: Email: Fax: Additional Information: Contractor: 1r►n 1c c \at Street Address: CD i t W: a h"\S G ' Town: (tieS State: llllCr Zip: 06011 10 Contact Name: / V1 _ - H Oy 4- Title: 17Q-f m _TTl n j ir5 S.5 4-rt. L Phone: 2 ,-`70\ -'?51 Jj V ey ill ) Cell: Email: 1\Vr If U .. NO3614r•Corn Fax: License Type: E WC. posSSZO State: License Number: El - 61 21 O5-I 1-1 IC-- txp. Date: El "� 3a 16 NIC--is I 6I1 'O Scope of Work: Subcontractor or Professional Engineer: 14 Street Address: Town: State: Zip: Contact Name: Title: Phone: Cell: Email Address: Fax: License Type: State: License Number: Exp. Date: Scope of Work: Please list on a separate sheet,included as attachment I all of the above subcontractor information for any additional subcontractors;employed on the project SOLAR PV SYSTEM INFORMATION Mounting Description Mounting Type(roof,pole,ground,other-specify): Rbb-i i Mounting System Manufacturer: S YIccf Li )Rae L Product Name and Model#: St_{, es O V (Continued) Version 5.1.2014 cTs. energize CONNECTICUT CT Standardized Solar PV Permit Application Building Information(For Roof-Mounted Systems Only) Building Type(e.g. house,shed,barn,slab): t1ou.S€ cl Building Height(in feet): 2 Is the building permitted?`igYes ❑No ❑NA If no,reason: Are there other permits associated with this application? ❑Yes ❑No Describe: Electrical Description A Size(amps)and type(phase,voltage)of electrical service: 12_0` 2'40 V I 103 A- Amperage of main breaker: On Will the value of main breaker change? ❑Yes Ni/No To: Rated amperage of the bus bar in the main panel: 1 0 0 Type of interconnection(e.g. breaker-load side,supply-side interconnect): Sc�►'�tf�� Electrical panel location: 3OS e YV\ev1.-i 1 V If load side interconnect,will solar intertie into a subpanel? ❑Yes ❑No If yes,rated amperage of the subpanel bus bar? Value of breaker protecting subpanel bus bar? Attachments for application (See Instructions on the next page. Example Attachments are available for download at www.energizect.com/sunrisene) ❑ 1.Additional Subcontractors and Information ❑ 2.One-Line Electrical Drawing ❑ 3.One-Line Site Plan Drawing ❑ 4.Attachment Details(Line Drawing)* ❑ 5.Solar PV Module Specification Sheets From Manufacturer ❑ 6. Inverter Specification Sheets From Manufacturer ❑ 7.Pole or Ground Mount Information(if applicable)* ❑ 8.Structural Review Worksheet(if applicable) ❑ 9.Additional Information for Large Solar PV Systems(as Specified by the Municipality) *NOTE:Applicants should submit either Attachment 4 for roof-mounted systems OR Attachment 7 for pole/ground- mounted systems, not both. Certification I hereby certify that❑I am the owner of record of the named property ore proposed work is authorized by the owner of record and/or I have been authorized to make this application as an auth rized agent,and we agree to conform to all applicable codes, laws, regulations and ordinances. All information contained within is true and accurate to the best of my knowledge and belief. No work shall start until the Jurisdiction has approved the permit or until the Contractor has received approval from_—_— _ _--� -- ---- --- (Jurisdiction Name) Signature of Property Owner or Authorized Agent: Typed or Printed Name of Signatory: v i 0. V k a .- .is _CYU Date: 1,2- I‹ S C� r Ing rest gsdc&r F Version 5.1.2014 . Ts energize . (rTM Permit#[For Jurisdiction Use]: CONNECTICUT CT Standardized Solar PV Permit Application Supplement Please fill in the following information and submit ALL applicable attachments. Date: 11 Si i S (� k , General Description of Solar PV Array: 'bL�t IM 6 µif‘� c `I-10 pane I S System Size(kW DC): )0.14 K_,..„J • Solar PV Mounting Information Mounting Type(roof,pole,ground,other-specify): Rpp-(' Mounting System Manufacturer: Sin c.p tJ R cic .— Product Name and Model#: S er i e_C 1.06 V Building Information(For Roof-Mounted Systems Only) Building Type(e.g.house,shed, barn,slab): 1-tOl. � Building Height(in feet): 29 1 Is the building permitted?>'es 0 No ❑ NA If no, reason: Electrical Description X Size(amps)and type(phase,voltage)of electrical service: l2O 2446 u )0 00 A Amperage of main breaker: i OO Will the value of main breaker change? ❑Yes %No To: Rated amperage of the bus bar in the main panel: 100 1 Type of interconnection(e.g. breaker-load side,supply-side interconnect): 5\f f I1 -- S' d'`� Electrical panel location: aQ►ti� J If load side interconnect,will solar intertie into a subpanel? 0 Yes ❑ No If yes,rated amperage of the subpanel bus bar? Value of breaker protecting subpanel bus bar? Attachments for application(See instructions on the next page. Example Attachments are available for download at www.energizect.com/sunrisene) WI 0 1.Additional Subcontractors and Information T4" 2.One-Line Electrical Drawing 3.One-Line Site Plan Drawing (V 4.Attachment Details(Line Drawing)* 5.Solar PV Module Specification Sheets From Manufacturer 6. Inverter Specification Sheets From Manufacturer 7. Pole or Ground Mount Information(if applicable)* p8.Structural Evaluation(if required by municipality). See page 3 for documentation requirements. cq 9.Additional Information for Large Solar PV Systems(as Specified by the Municipality) *NOTE:Applicants should submit either Attachment 4 for roof-mounted systems OR Attachment 7 for pole/ground- mounted systems,not both. Version 8.1.2014 energizeTm CONNECTICUT Instructions for ATTACHMENTS to the Connecticut Standardized Solar PV Permit Application Please Complete-the Application Form(page 1)and provide-all-applicable Attachments based on the below instructions for Attachments 1 8:Attachment 8 is'a Structural:Evaluation to be completed if required by the municipality Additional`information required=bwa-municipality for large solar PV systems he submitted as a 9th h v Attachment:Example Attachments_(e g sample drawings)can be found at www.enerOizect:com/sunnsene. Each Attachment—Subcontractor List and (Attachment 2 continued) Drawings—Must Include: • Interconnection method • Date -Size of overcurrent protection • Property Owner • Number,type and electrical configuration of solar -Name panels -Address • Number and type of Inverters -Contact phone number •Values for source stickers: NEC 690.53; NEC 690.54 (Encouraged, Not Required) • Installation Company •Wiring methods -Name of company and contact person -Wire Type(s), Size -Address -Conduit Type(s),Size -Contact phone number •Solar metering(If Appropriate) • Drawing number and Revision number or other control method • Electrical current contribution from all PV sources • Drawing designer • Electrical grounding details:Wire Type,Size,GEC Attachment 1.Additional Subcontractor List Attachment 3.One-Line Site Plan Drawing Must Show: (If Needed,as per Permit Application) • Location of solar panels • Location of Inverters and major equipment Attachment 2. One-Line Electrical Drawing • Location of roof obstructions(Vents,Chimneys,etc.) Must Show: • Location of Main Breaker Panel • Size of electrical service • Location of Utility Meter -Size of Main Breaker • Location of AC disconnect -Size of Bus Bar(If Known) • Location of batteries and/or charge controllers(If •Type of electrical service Appropriate) • If interconnection point is a subpanel • Location of solar metering(If Appropriate) -Size of Subpanel Main Breaker • Planned conduit path(Encouraged, Not Required) -Size of Subpanel Bus Bar(If Known) •Gross dimensions of structure(If Appropriate) • Nominal power of solar system(Watts) •Approximate layout of building or other structure -DC Capacity: Nameplate "STC"Value of all (If Appropriate) panels,watts • Property lines,zoning,and setback considerations -AC Capacity:Total AC capacity of Inverters,watts (If Appropriate) • Batteries (If Present):Type,Quantity, Nominal •Trenching details: Location, Depth and Length of Voltage,Capacity kWh Trench(If Appropriate) -H2 mitigation methods(If Necessary) •A notation indicating scale—or not to scale (Both are Acceptable) Version 8.1.2014 Town of Montville Building Department File Receipt Date: 15-Dec-15 ReceiptNo: 10992 Received From: Trinity Solar Job Address: 25 Pheasant Run Town Fees Collected State of Connecticut Fees Collected Bldg Cash: $0.00 State Cash: $0.00 Bldg Check: $477.82 State Check: $9.82 Bldg Credit: $0.00 State Credit: 10.00 Fire Cash: $0.00 Fire Check: $0.00 Fire Credit: $0 0Q Construction Value: 137.7,57.00 Demolition Value: $0.00 CheckNo: 3875 Received By: Carmen KneelandCj1%,,/1EC ¢,zjaz.-/V4 Address: 467 Chesterfield Road ITEM OTY $/UNIT TOTAL Building Plumbing Mechanical Electrical BUILDING AREA Basement,Finished SF $ 41.96 $ - $ - Interior Renovations SF $ 36.09 $ - $ - $ AMENITIES Kitchen EA $ - $ _ $ Full Bathroom EA $ _ $ Half-Bathroom EA $ - $ - GARAGE Detached SF $ 71.53 $ - $ MECHANICAL Warm-Air n Y/N $ _ Hot Water n Y/N $ Electric n Y/N Air Conditioning n Y/N $ - ELECTRICAL SERVICE Upgrade Amps $ Subpanel EA $ 699.00 $ Gen Set EA $ 3,850.00 $ SOLID FUEL BURNING APPLIANCES Prefab Metal Fireplace EA $ 6,497.70 $ - Masonry w/lfireplace EA $ 7,096.65 $ - Masonry w/2 fireplaces EA $ 11,095.70 $ - Wood Stove,fres standing EA $ 2,692.25 $ Woodstoveinsert EA $ 1,859.77 $ - DECKS,PORCHES,SUNROOMS Deck SF $ 44.07 $ - Porch SF $ 149.38 $ - Sunroom SF $ 176.90 $ - $ POOLS&HOT TUBS Hot Tub EA $ 8,016.25 $ - Inground Pool E4 $ 31,550.00 $ - $ _ Above Ground Round E4 $ 6,299.46 $ - $ Above Ground Oval EA $ 7,019.75 $ - Pool Heater EA $ 8,984.25 $ - - Inflatable Type Pool EO $ 1,200.00 $ - $ SHEDS w/o electrical SF $ 25.55 $ - w/electrical SF $ 26.85 $ - $ - RENOVATIONS Roofing,Overlay SF $ 3.50 $ - Roofing,Strip&reroof SF $ 4.50 $ - Roof Sheathing - SF $ 1.51 $ - Siding - SF $ 6.75 $ - Windows E4 $ 550.00 $ - Skylights EA $ 1,051.10 $ - Doors,Exterior EA $ 601.50 $ - Oil Tank,275 Gallon - EA $ Oil Tank,550 Gallon EA $ - MISCELLANEOUS CALCULATIONS $ 2,643.00 $ 35,109.00 TOTALS $ 2,643.00 $ - $ - $ 35,109.00 PERMIT FEE CALCULATIONS Construction Value Fee Building $ 2,643.00 $ 36.00 Plumbing y $ - $ - Mechanical y $ - $ _ Electrical y $ 35,109.00 $ 432.00 Working before Permit Issuance $ Certificate of Occupancy Fee $ Plan Review Fee $ State Education Fee $ 9.82 TOTALS $ 37,752.00 $ 477.82 Figures are based on the 2006 RS Means Residential Cost Data energize cr CONNECTICUT Instructions for ATTACHMENTS to the Connecticut Standardized Solar PV Permit Application Attachment 4.Attachment Details for Roof-Mounted Attachment 8.Structural Evaluation(if required by Systems(Line Drawing)Must Show:* the municipality) • Racking System • NOTE: If this Attachment is required by the —Manufacturer of racking structure municipality it must be submitted in a format accepted —Model by the municipality(see two examples,listed below). Installers should contact the municipality's Building —Type Department to determine what documentation • Flashing description will meet the municipality's Structural Evaluation • Fastener detail requirements. —Type of fasteners,e.g. Lag Screws,Seam Clamps, Two potentially acceptable formats are: Ballast 1.Structural Review Worksheet(available at www. o If Lag Screws include: energizect.com/sunrisene). This worksheet can (1)Type(e.g.Zinc,Stainless steel) be used by an installer to meet the Structural (2)Size of Lag Evaluation requirements of a municipal Building (3)Depth of Thread Penetration Department if the department specifically (4)Type of Sealant(e.g.caulk) authorizes its use for that purpose. • Mitigation of Dissimilar Metals OR —Describe how any dissimilar metals will be isolated 2. Proof of a Structural Review performed by a Registered Design Professional(e.g. Professional Attachment 5.Solar PV Module Specification Sheets Engineer). (provide PDF from manufacturer) Attachment 9.Additional information required for Attachment 6. Inverter Specification Sheets larger solar PV systems (provide PDF from manufacturer) •This Standardized Solar PV Permit Application Attachment 7. Pole Mount or Ground Mount Supplement can also be used to permit larger Information (if applicable):* systems. If a municipality requires additional information to permit larger systems,they should • Racking system specify the information needed as a 9Lh attachment to • Mounting specification sheets and details from the application. manufacturer(PDFs) • Manufacturer's Pre-Engineered Document or PE Stamp •Code Compliance Manual(If Requested by Municipality) •One-way distance from the Solar PV system to the interconnection point • Electrical grounding details • Height of solar PV system at maximum design tilt •Applicable zoning information if not shown on site plan(e.g.setback from property line) *NOTE:Applicants should submit either Attachment 4 for roof-mounted systems OR Attachment 7 for pole/ground- mounted systems, not both. Version 8.1.2014 IMI111111.0111.11111 NEVEMono Multi Solutions ■ ■ IIUIIIIIIH ■ THE iv rs niii"■■■ n IIIIIIIILUOII II ■ ■ ■ MODULE 1111Uh1■ ■ I■■■ ■ 6OCELL ■lilt ■■ MULTICRYSTALLINE MODULE liLili PD05.08 PD05 245 -260W POWER OUTPUT RANGE Our most versitile product • Compatible with all major BOS components and system designs 15.9% • 1000V UL/1000V IEC certified MAXIMUM EFFICIENCY One of the industry's most trusted modules • Field proven performance 0 +3% POWER OUTPUT GUARANTEE Highly reliable due to stringent quality control • Over 30 in-house tests (UV,TC, HF, and many more) As a leading global manufacturer ° • In-house testing goes well beyond certification requirements of next generation photovoltaic products,we believe close • PID resistant cooperation with our partners is critical to success. With local presence around the globe,Trina is able to provide exceptional service to each customer in each market Certified to withstand challenging environmental and supplement our innovative, reliable products with the backing conditions of Trina as a strong,bankable 2400 Pa wind load partner. We are committed 5400 Pa snow load to building strategic,mutually beneficial collaboration with installers,developers,distributors and other partners as the backbone of our shared success in driving Smart Energy Together. LINEAR PERFORMANCE WARRANTY Trina Solar Limited 10 Year Product Warranty • 25 Year Linear Power Warranty www.trinasolar.com Addifio�ol value v 9096 front Trina go/ar' linepr Horrpnfy THE Universal MODULE PRODUCTS POWER RANGE ELECTRICAL DATA(STC) TSM-PD05 245-260W Peak Power Watts-PMAx(Wp) 245 250 255 260 TSM-PD05.08 245-260W Power Output Tolerance-PMAx(%) 0-+3 Maximum Power Volage-VMPP(V) 29.9 30.3 30.5 30.6 DIMENSIONS OF PV MODULE Maximum Power Current-IMPP(A) 8.20 8.27 8.37 8.50 unit:mm Open Circuit Voltage-Voc(V) 37.8 38.0 38.1 38.2 941 Short Circuit Current-Isc(A) 8.75 8.79 8.88 9.00 "7 Module Efficiency rlm(%) 15.0 15.3 15.6 15.9 UNRION Co- Rox STC:Irradiance 1000 W/m',Cell Temperature 25°C.Air Mass AMI. . NAMEPLATE _. Typical efficiency reduction of 4.5%at 200 W/m'according to EN 60904-1. 0 !- 4.09x12 INSTALLING HOLE ELECTRICAL DATA(NOCT) Maximum Power-PMAx(Wp) 182 186 190 193 Maximum Power Voltage-VMPP(V) 27.6 28.0 28.1 28.3 0 V3 MD Maximum Power Current-IMPP(A) 6.59 6.65 6.74 6.84 o Open Circuit Voltage-Voc(V) 35.1 35.2 35.3 35.4 Short Circuit Current-15c(A) 7.07 7.10 7.17 7.27 NOCT:Irradiance at 800 W/m',Ambient Temperature 20°C,Wind Speed 1 m/s. • 6-04.3 GROUNDING HOLE A A /12-DRAIN HOLE MECHANICAL DATA Solar cells Multicrystalline 156 x 156 mm(6 inches) / N. 812 11800 I Cell orientation 60 cells(6 x 10) Module dimensions 1650 x 992 x 35 mm(64.95 x 39.05 x 1.37 inches) Back View Weight 18.6 kg(411b) Glass 3.2 mm(0.13 inches),High Transmission,AR Coated Tempered Glass Backsheet White Frame Silver Anodized Aluminium Alloy(PD05);Black(PD05.08) :It' II'65 or 67 rated Cables Photovoltaic aic Technology cable 4.Omm'(0.006 inches'), 700 mm(27.56 inches)/1000mm(39.37inches) Connector MC4 35 I A-A TEMPERATURE RATINGS MAXIMUM RATINGS I-V CURVES OF PV MODULE(245W) Nominal Operating Cell 44°C(+2°C) Operational Temperature -40-+85°C Temperature(NOCT) Maximum System 1000V DC(IEC) 10. Temperature Coefficient of PMAx -0.41%/°C Voltage 1000V DC)UL) 9.J0 1000W/m' Temperature Coefficient of Voc -0.32%/°C Max Series Fuse Rating 15A 8.a 800W/m' 6. Temperature Coefficient of lsc 0.05%/°C c '� 600W/002 0 5.00 U 4.. 400W/m' 300 \ WARRANTY 2.00 200W/m' ,,..i."- 10 year Product Workmanship Warranty 100 0.00 --- - - ' 25 year Linear Power Warranty N 0.00 10.00 2000 30.. 40.00 (Please refer to product warranty for details) a Voltage(V) 0 N 1 CERTIFICATION S PACKAGING CONFIGURATION ao C E °®" Modules per box:30 pieces w I Modules per 40'container:840 pieces 40%. A PVtYCLE i«1 ISO • CAUTION:READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT. solar "' oc W SolarEdge Single Phase Inverters C�C For North America W SE3000A-US / SE3800A-US / SE5000A-US / SE6000A-US / SE7600A US / SE10000A-US/ SE11400A-US �pvertee F: •� l 12'25 Vests watca'ty •Ian anON ft " a r fa fll- i fi The best choice for SolarEdge enabled systems ▪ Integrated arc fault protection (Type 1)for NEC 2011 690.11 compliance - Superior efficiency(98%) Small, lightweight and easy to install on provided bracket Built-in module-level monitoring ▪ Internet connection through Ethernet or Wireless — Outdoor and indoor installation Fixed voltage inverter, DC/AC conversion only — Pre-assembled Safety Switch for faster installation Optional—revenue grade data,ANSI C12.1 USA-GERMANY-ITALY-FRANCE-JAPAN -CHINA-AUSTRALIA-THE NETHERLANDS-ISRAEL www.solaredge.us solar - • • --- Single Phase Inverters for North America SE3000A-US I SE3800A-US I SE5000A-US I SE6000A-US SE7600A-US/SE10000A-US/SE11400A-US r000A-US 1 SE3800A-Us SE5000A-US SE6000A-US SE7600A-US 5E10000A-US SE11400A-US OUTPUT 9980 @ 208V Nominal AC Power Output 3000 3800 5000 6000 7600 11400 VA 10000 @240V 5400 @ 208V 10800 @ 208V Max.AC Power Output 3300 4150 6000 8350 12000 VA 5450 V240V 10950 V240V AC Output Voltage Min.-Nom.-Max.(i) _ - .1 - - 1 - 183-208-229 Vac AC Output Voltage Min.-Nom.-Max.‘') .1 1 1 1 1 / 1 211-240-264 Vac AC Frequency Min.-Nom.-Max.'" 59.3-60-60.5(with HI country setting 57-60-60.5) Hz 24 @ 208V I 1 48 @ 208V Max.Continuous Output Current 12.5 16 25 3247.5 A V 21 240V 42 e 240V GFDI Threshold I 1 A Utility Monitoring,!standing Protection,Country Configurable Thresholds Yes Yes INPUT Maximum DC Power(STC) 4050 1 5100 1 6750 1 8100 1 10250 j 13500 1 15350 W Transformer-less,Ungrounded I Yes Max.Input Voltage I 500 Vdc Nom.DC Input Voltage 325 @ 208V/350 @ 240V Vdc 16.5 @ 208V ' 1 33 @ 208V 121 95 13 18 I 23 34.5 Adc Max.Input Current9 t 15.5 240V 30.5240V Max.Input Short Circuit Current I 45 Adc Reverse-Polarity Protection I Yes Ground-Fault Isolation DetectionI600ko Sensitivity • Maximum Inverter Efficiency 97.7 98.2 98.3 1 98.3 98 98 98 % 97.5 @ 208V 97 @ 208V CEC Weighted Efficiency 97.5 98 97.5 97.5 97.5 % 98 V 240V 97.5 V 240V Nighttime Power Consumption <2.5 I < I W ADDITIONAL FEATURES Supported Communication Interfaces RS485,RS232,Ethernet,ZigBee(optional) Revenue Grade Data,ANSI C12.1 Optional Rapid Shutdown-NEC 2014 690.12 Functionality enabled when SolarEdge rapid shutdown kit is installee STANDARD COMPLIANCE Safety IUL1741,UL1699B,UL1998,CSA 22.2 Grid Connection Standards IEEE1547 Emissions FCC part15 class 8 INSTALLATION SPECIFICATIONS AC output conduit size/AWG range 3/4"minimum/16-6 AWG 3/4"minimum/8-3 AWG DC input conduit size/U of strings/ 3/4"minimum/1-2 strings/ 3/4"minimum/1-2 strings/16-6 AWG AWG range14-6 AWG Dimensions with Safety Switch 30.5 x 12.5 x 10.5/ in/ 30.5 x 12.5 x 7.2/775 x 315 x 184 (HxWxD) 775 x 315 x 260 mm Weight with Safety Switch j 51.2/23.2 I 54.7/24.7 88.4/40.1 I lb/kg Natural convection Cooling Natural Convection and internal Fans(user replaceable) fan(user replaceable) Noise <25 <50 dBA Min.-Max.Operating Temperature -13 to+140/-25 to+60(-40 to+60 version available)) 'F/'C .• Range, Protection Rating NEMA 3R olFor other regional settings please contact SolarEdge support. MA higher current source may be used;the inverter will limit its input current to the values stated. '1Revenue grade inverter P/N:SExxxxA-US000NNR2(for 7600W inverter:SE7600A-US002NNR2). 'I Rapid shutdown kit P/N:SE1000-RSD-S1. 51-40 version P/N:SExxxxA-US000NNU4(for 7600W inverter:SE7600A-US002NNU4). 0 C[11111 RoHS ©SolarEdge Technologies,Inc.All rights reserved.SOLAREDGE.the SolarEdge logo,OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies.Inc.All other trademarks mentioned herein ,re trademarks of their res.ective owners.Date:12 2014.V.01.Sub ect to chan:e without notice. solar LL, SolarEdge Power Optimizer Module Add-On For North America P300 / P350 / P400 / P405 CL C W 0 • 25 ,,8,; .p y^� • PV power optimization at the module-level Up to 25%more energy • Superior efficiency(99.5%) • Mitigates all types of module mismatch losses,from manufacturing tolerance to partial shading • Flexible system design for maximum space utilization — Fast installation with a single bolt ▪ Next generation maintenance with module-level monitoring — Module-level voltage shutdown for installer and firefighter safety USA - GERMANY - ITALY - FRANCE - JAPAN - CHINA - ISRAEL - AUSTRALIA www.solaredge.us solar - • • elk SolarEdge Power Optimizer Module Add-On for North America P300 / P350 / P400 / P405 P300 P350 P400 P405 (for 60-cell modules) (for 72-cell modules) (fir 96-cell module, (for thin film modules) INPUT Rated Input DC Powerltt 300 35U 400 405 W Absolute Maximum Input Voltage 48 60 80 125 Vdc (Voc at lowest temperature) MPPT Operating Range 8 48 8-60 8-80 12.5-105 Vdc Maximum Short Circuit Current(Isc) 10 Adc Maximum DC Input Current 12.5 Adc Maximum Efficiency 99.5 % Weighted Efficiency 98.8 % Overvoltage Category II OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING INVERTER) Maximum Output Current t', Adc Maximum Output Voltage i.tl 85 Vdc OUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF) Safety Output Voltage per Power Otlld„ Vdc STANDARD COMPLIANCE EMC FCC PartiS Class 8,IEC61000-6-2,IEC61000-6-3 Safety IEC62109-1(class II safety),UL1741 RoHS Yes INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage 1000 Vdc Dimensions(WxLxH) 141 x 212 x 40.5/5.55 x 8 34 x 1.59 mm/in Weight(including cables) 950/2 1 gr/lb Input Connector MC4/Amphenol/Tyco I MC4 Output Wire Type/Connector Double Insulated;Amphenol Output Wire Length 0.95/3.0 I 1.2/3.9 m/ft Operating Temperature Range -40-+85/-40-+185 °C/'F Protection RatingIP65/NEMA4 Relative Humidity 0-100 % I'i Rated SIC power of the module Module of up to♦SPC power tolerance allowed PV SYSTEM DESIGN USING SINGLE PHASE THREE PHASE 208V THREE PHASE 480V A SOLAREDGE INVERTERm Minimum String Length 8 10 18 (Power Optimizers) Maximum String Length 25 25 50 (Power Optimizers) Maximum Power per String `::),)) 6000 12750 W Parallel Strings of Different Lengths Yes or Orientations :Pit Is not allowed to mix P40r with f]oo/P3,o/p4o0/P000/1`700 in one string 4 CE ETA ,mu a4 I nl V n, 41 wrl eservcni SDtARLDC, hr of ,,,,,,c. ) IMI/EC C t._ARI Lt... IMI'gni len hr ur•n rHRI..It.n ll Jtll lellydIu......o Wl Lrlep FBA 111,s nr t,`: 1a -d 11 I it!. r hl1,111 Id!,, 111,110ntrl 111 rinl Ir f- ;idlie111,1 -;ladenldi-- neo res,e,.I Ph owner'; ✓.dr .IL 20l r1 .01 ',lxe.' .,,:ndrtl;c'.vdhou,nuuce I Photovoltaic S St Labeling Requirements Y e m for Article 690 1._ABELING NECa 690.13(B)hallbeermach photnentyvmak system tit asna means shall be permanently marked to identify it a photovoltaic system disconnect. NEC 690.15,IFC 605.11.3 If the equipment is energized R E Q U I R E IVI E N T S from more than one source,the disconnecting means must be grouped and identified. NEC 690.16(B) Non-load break rated disconnect means NEC 2014 ARTICLE 690 AND IFC 2012 shall be marked. NEC 690.17(E)Where all terminals of the disconnecting means may be energized in the open position,a warning label shall be mounted on or adjacent to the disconnecting Adhesive Fastened Signs means NEC 690.31(B)Identification and Grouping Photovoltaic ANSI Z535.4—2011 Product safety Where required elsewhere in this system conductors shall be identified and grouped. The means color signs and labels, provides guidelines code and field applied labels, coding,Dmarking f itape,tagging or other approvedcation shall be permitted byarate mean. for the design and durability warning(s)and marking shall NEC 690.31(G)(3)(4), IFC 605.11.1.2 Labels shall of safety signs and labels for comply with ANSI Z535.4. appear at every section of the wiring system that is application to electrical equipment. NEC 110.21(6)HELD MARKING separated by enclosureswally partitions ceilings or floors. NEC 110.21(6)(1) Spacing between labels not to exceed 10 feet(3M). Adhesive fastened signs may be NEC 690.33(E)(2) Interruption current- be a type that The label shall be suitable for the acceptable if properly adhered. Vinyl requires the use of a tool to open will be marked'Do Not environment where it is installed. signs shall be weather resistant. Disconnect Under load'. NEC 690.35(F) A PV power source shall be labeled at NEC 110.21(6)(3) IFC 605.11.1.3 each junction box,combiner box or disconnect and device where energized, ungrounded circuits may be exposed 0 Breaker Panel/Pull Boxes l Main Service Disconnect during service. AWARNING d WARM WARNING NEC 690.31(G)(1)Where circuits are embedded in build ELEC.IwLAL 0HOLrc HALAKU rLe i,-AL JHULA H ELECTRICAL SHOCK HAZARD PV modules and associated equipment,the location of the t C TAIC Dc CAVOUCH URONOIJCIO E s UI:o=0ROrws tIVDED DO NOT TOUCH TERMINALS NGRYALLY GROUNDED CONDUCTORS ""OIOVOLTERMINALS ON BOTH LINE AND circuits shall be dearly marked. MAY RE UNGROUNDED AND ENERGIZED ANO MAY ME ENERCIIED LOAD SIDES MAY BE ENERGIZED Mc bid 5;U ra°No 531,(AAA M.610 sirs var No 09b11410M IN THE OPEN POSITION NEC 690.31(1)Bipolar photovoltaic systems shall be dearly NE(C90 nkri Pot No(96 C0191 marked with a permanent,legible warning notice indicating WARNING I A WARNING 1 that the disconnection of the grounded conductor(s)may ELECTRICAL SHOCK HAZARD IL4404-E 170.VOCT SUPPLY A WARNING result in overvoltage on the equipment DO NOT TOUCH TERMINALS TERMINALS ON BOTH LINE AND DO NOT CONNECT TURN OFF PHOTOVOLTAIC LOAD SIDES MAY BE ENERGIZED SIUCT1W E BRANCH CIRCUITS AC DISCONNECT PRIOR T4 NEC 690.5(C)A label shall appear on the utility interactive IN THE OPEN POSITION WORKING INSIDE PANEL inverter or be applied by the installer near the round fault N,,023 7,;1)volt NI)54o 9-249 %Lan ioiI Pat No 596-M3 9 Nr,Sia 5;C) 93 N 53P 0319 indicator at a visible location. R iA WARNING • UNDER LOAD NEC 690.52 AC modules shall be marked with TURN OFF PHOTOVOLTAIC It,2 Pa- 52 4 MAIN PHOTOVOLTAIC identification terminals or leads with the ratings as shown AC DISCONNECT PRIOR TO SYSTEM DISCONNECTonthe label. WORKING INSIDE PANEL PH010vCH.TA1C AC DISCONNECT NEC 690.53 A permanent label for the direct-current PV Nt.1111 MI a mRA 1910 14500 � power source shall be provided by the installer at the PV Pot No 59600499 CAUTION:SOUR ELECTRIC disconnecting means. SYSTEM CONNECTED DUAL RtaRtSaliRCE NEC 690 Is a NEC 69913E10 Pat(No 55B-006i) NEC 690.54 All interactive system points of interconnection N a with other sources shall be marked at an accessible location at the disconnecting means as the power source and with „Y•,En„&WR NG an,00.401, al Main Service Disconnect the rated AC output current and the nominal operating AC MINOE�?i 5s12(D Era voltage. MAIN PHOTOVOLTAIC CAUTION SYSTEM DISCONNECT NEC 690.55 PV power systems employing energy storage "' " "`EM,.� *.• vE• shall also be marked with the maximum operating voltage, Ncc30,1s{A3)a R.64) including any equalization voltage and polarity of thePat No 536 97537 grounded circuit conductor. NEC 690.56(C) Each Rapid Shutdown Switch shall be permanently marked to identify it as a Photovoltaic NEC 705.12(D)(3)(B)In systems with NEC 705.12(D)(3) NFPA 2012 130.5(C) Rapid Shutdown. The sign or placard shall be marked panel boards connected in a series the Equipment containing Same as NECI 10.16 but includes as 'PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID rating of the first overcurrent device overcurrent devices in additional label information that is SHUTDOWN"using white letters that are 3/8'tall on a red directly connected to the output of the circuits supplying power required after 9/30/2011.Check latest background and shall be reflective. utility,interactive inverter(s)shall be to a busbar or conductor 2012 NFPA Arc Flash requirements used in calculations for all busbars and supplied from multiple NEC 690.64 Points of connection shall be in accordance conductors A permanent label shall be sources shall be marked to OSHA 1910.145(F)(7) with NEC 705.12. applied to the distribution equipment indicate the presence of all Warning tags are used to represent a with the following or equivalent sources hazard level between"Caution"and wording. Danger" Hellermannnnnnlyton -.4404,500 a 0� + R. 0 W, This diagram is an illustration of one a• �.- photovoltaic labeling scenario The ' - number and type of labels needed will 0 vary based on the project scope a , . © 41 and its related specifications 00 t Check with AHJ for �•- --- local requirements • �.. NEC AnKe 11016 aM WA 70E /0 NuicN 1305(CXI1(2t(3) O / Pan No 550-00 61 0 G f W+ • INV1 / A=BLACK FEE NEC 406400 B=RED SECOND SERVICE DISCONNECT Pal No 556003 W. C=BLUE ON NORTH SIDE OF BUILDING NEUTRAL=1'JH'TE ,,F,;;,11(0,<<;�hI0: X2111.0 556 00 313 PHOTOVOLTAIC SYSTEM I NOTE 00gti kW a ked5tr.re In rNEEC Palo 5 0630101 XS/ EQUIPPED WITH rtK61[2 kW marked re Ina NEC Cd! Pal No 556301 vs-Tran 11 is p1110111126u'Or)or SNUDUI5(t•tor THIS PANEL FED MAX AVAILABLE FAULT CURRENT 46,552 AMPS RaRAPID SHUTDOWN Ran dAEL r,D outs)P/P[Ext[J LY Rcn than crz SErY!tE FROM INVt DATE 2715214 ' • COR0er 0..putt''r WHITS riga a armoury aro a EY System) FIR NEC 340 0(M) FOR NEC 110 2µ D D A)PMI Na 5 8 C0313 NEC Ae 690`01(1 Gan NO S96-OC474 14:s k4�dF=An flail,and�r.'enzna�l H:etra Can No S56 C0313 o Combiner Box,Circuits/Conduit Combiner Box/ • EMT/Conduit Raceways Enclosures/EMT Enclosures '(reef" '`` • AWARNING 1 pWARNING WARNING: PHOTOVOLTAICWARNING WiOTOVOLUUC POWER SOURCE ELECTRICAL SHOCK HAZARD ELECTRICAL SHOCK HAZARD POWER SOURCE "�_..'Y L•' »_..�-_..U. E DO NOT TOUCH TERMINALS THE OC CONDUCTORS OF THIS NEC 690 31(GX3X4)Pan tOJ 59b-P)]Cb `J'C F,9^i'IGtr) 9a1 Sr536 X115' LOAD SIDES ON BEEH LINE AND PHOTOVOLTAIC SYSTEM ARE UNGROUNDED LOAD SIDES MAY SiTIONENERGED AND MAY SE ENERGIZED IN THE OPEN POn No 5 0 0 Production/Net Meter NEC 699 t 7(E)PMI No 536 00'31 NEC 690 3',!i I Part No 596.0Ji35 Inverter A WARNING 0 Building/Structure A WA I4- '',T `i. `' ELECTRICAL SHOCK HAZARD a ELECTRICAL SHOCK HAZARD TURN OFF PHOTOVOLTAIC CWEION IFAGROUND FAUL.:. _..ATEA KAGROUNO FAULT IS INDICATED AC DISCONNECT PRIOR TO DIC NORMALLY GROUNDEDCONDUCTr7RS NOPMULV0000NINOCON000TORS WORKING INSIDE PANEL ( -' A MAY SE UNGROUNDED ANDENEAGRED MAY DE UNGROUNDED A/40 ENERGIZED �'C l�r.:'�-I E..",a0 1911,,r:E((i 9 E 1 NEC 699 Y)Prat No 1,35 00493 N;C 690 5(C)Part No 596-90430 =2li Ni i96:i:93 l� A WARNING 0 Production/Net Meter NEC 690 514131 Pan No 5%0)341 (Bi-directional) BIPOLAR PHOTOVOLTAIC ARRAY. o DC Disconnect/Breaker/Recombiner Box DISCONNECTION OF NEUTRAL OR GROUNDED CONDUCTORS pp���� MAY RESULT IN OVERVOLTAGE 4.W, lV�ING PHOTOVOLTAIC ON ARRAY OR INVERTER CAUTION:SOLAR ELECTRIC V N=:63131{')Pan 50 596 00590 SYSTEM CONNECTED ELECTRICAL SHOCK HAZARD DC DISCONNECT NEC 63)ti3 NEC 60)13',31 Tan No 5530]6H THE 1)0 cawUCTOO OF U114PHOTOVOLTAIC AC DISCONNECT GI OVER TAR sysIEM ARE UNGRDuvDeD IF 679113,NEC 0) b9713{31 P39 Na 53"4'1)233 - ADD MAY DE CNEROMED _ - ,Err N>S 1E33 PHOTOVOLTAIC SYSTEM N{69)51 Paa NI 536 0)233 NEC 125 I2;OX316NEC 63)W P#1 09435 • DC DISCONNECT .A WARNING r1:,ERATING7U4FENT 0 ,,ee,:1.,_VT TORE AC Disconnect/Breaker/Points of Connection ELECTRICAL SHUCK HAZARD I,,,,JV S.50_1/ GLIA TEE - i •,� PHOTOVOLTAIC "" -�-`4 ` 00BIM NOTTOUCH TEEn NUE ALS rl.ORT CISCO"CURRL�\' ”......-..;-1',....-...L....•.-.7.s TLRMINAL•u DN 60TH UNE AND - ♦ It_ LOAD RIDES YAY 6E POSITION — IHTHEOPENPO,.. .._ N•T AC DISCONNECT 1''•:'`:"'--•.,,. OC VOLTAGE IS AR MODULES ESENT Ly L'I'I'' ".. EMI SOLARTO SUNLIGHT IFC 605 11 3,NEC 697 15.NEC 630)3(6) 7,",;•:.:,•.•.,"!,;Z 'N, ARE EXPOSED 10OSUNNo 59 TOTED MAK POWERiDM CONTENT- Part No 59600237 P. -" NEC 69)--` Part Se 596-00696 DATED MAI PTYNFNOOPR VOLTAGE- {'V','; i:-: "."11., WWII _ __ AINUN SYSTEM 001006EMEI NEC`. . Pal No•_ _ ..':•;;•:,- - MwKNUM cwcurt cuNREHr t'1" `--'" �- 1.L=_'NEM NAYRA•Oou,FulcuACE.TOl ELECTRICAL SHOCK HAZARD TA MEM `-1 3 ,1 :NMIMI EM -..ew. PHOTOVOLTAIC AC DISCONNECT DO NOT TOUCH TERMINALS TA NEC 690 53 Rn No 5960)253 TERMINALS ON BOTH LINE AND - H P ••'• t_ LOAD SIDES MAY BE ENERGIZED lEf,I I "y„ IN THE OPEN POSITION NEC 64:13;51 Pan No 596 02239 :;� NEC 63)14E1?RA N,536.9)497 Requirements for Electrical Installations (Field Marking) NEC 110.16 Electrical equipment that NEC 110.27(C)Entrances to rooms or other NEC 210.5(CX1)(B)Branch Circuits:The NEC 408.4(B) are in other than dwelling units shall be guarded locations that contain exposed live identification methods used for conductors All switchboards and field marked to warn qualified persons of a parts shall be marked with conspicuous warning originating within each branch circuit shall panelboards supplied by a feeder potential Arc Flash hazard signs forbidding unqualified persons to enter, be documented in a manner that is readily in other than one or two family available or shall be permanently posted dwellings shall be marked to NEC 110.24(A)Service equipment in other NEC 230.2(E)Where a building or structure at each branch-circuit panelboard or indicate the device or equipment than dwelling units shall be legibly field is supported by more than one service,add a distribution equipment where the power supply(s) marked with the available fault current plaque to denote all other services originates 0 www.hellermann.tyton.com 800.537.1512 SERIES 100 UL ROOF VOU \ T SYSTEV SnapNrack Solar Mounting Solutions The SnapNrack line of solar mounting solutions is designed to reduce total installation costs. The system's technical innovations have been proven to drive down costs and improve installation quality on more than 350 MW of solar installations. Pitched Roof Arrays Simplified The SnapNrack Series 100 UL Roof Mount System is an efficient, visually appealing, photovoltaic (PV) module installation system. Series 100 UL is listed to the UL 2703 Standard for Bonding, meaning that all system components have been certified by UL for Roof System in 4 Simple Steps: electrical continuity, eliminating the need for additional grounding hardware. The System's components provide 1) Go to the online Series 100 Configuration an adequate bonding path which has eliminated the Tool (configure.snapnrack.com) and select need for grounding lugs and washers at each module, "Yes" for UL 2703 Listed and bonding jumpers between splices. The UL 2703 2) Identify Site Conditions (Array Tilt, Building Certification ensures that SnapNrack partners can Height, Roof Type, Wind and Snow Loads) provide the best in class installations in quality, safety, 3) Build array in the online Configuration and efficiency. Tool and automatically generate a Bill of • All bondinghardware is fullyMaterials. integrated into the components 4) Place order with your distributor. Purchase material for a single project or order in bulk • No grounding lugs required for modules for additional savings • Rail splices bond rails together, no rail jumpers required • Proprietary SnapNrack grounding lug snaps in the rail channel, no drilling of rail or reaching for other tools required (One Lug per individual row of modules) Patent Pending el LISTED PV Mounting System 2703 . Farn,,„01 GREAVEB POWER DISTRIBUTION 0 BUG•BITESTM �S'A`• c 90AC Insulation Piercing Connectors ,`•,,,. Eliminates need for conductor insulation stripping US1ED • 4:60,0111 ''j No taping required after installation " For copper to copper,copper to aluminum, or aluminum to aluminum applications r - For use on insulated conductor only is 1. jr- IPC SERIES NAED CATALOG WIRE RANGE _ TORQUE CTN •_EST.SHIPPING__ NUMBER NUMBER MAIN TAP VOLTS BOLTS FT-LBS QTY WEIGHT(ibs) UNIT -r 13110 IPC 1002 1/0-8 2-8 300 1 16 12 2.63 CTN .- 13107 •IPC 4006 4/0-4 6-14 600 1 13 12 1.90 CTN ` 13108 'IPC 4020 4/0-2 2/0-6 600 1 25 12 4.08 CTN s, � • ..1:1:'7-:-1 • 13109 'IPC 2540 250-1 4!0-6 600 1 30 6 4.17 CTN -1... CTN / 13113 IPC 3540 350-4/0 4/0-10 300 1 25 6 4.17 CTN 13114 IPC 3535 350-4/0 350-4/0 300 2 25 6 7.63 CTN 13116 t IPC 5012 500-250 10-12 300 1 25 4 2.85 CTM 13104 •IPC 5025 500-250 250-4 600 1 55 4 4.06 CTM _ 13105 *IPC 5050 500-300 500-250 600 1 75 1 2.64 EA CAUTION 13106 IPC 7550 750-500 500-350 600 1 75 1 2.62 EA Use Bug-Bites on '600 Volts,balance 300 Volts(for 480V grounded Y systems) insulated cable only! t Not CSA certified Do not install on bare cable. Dual-Rated GUTTER TAP CONNECTORS 121 a CU9AL High strength aluminum alloy 6061-T6, tin-plated USTEp 600V 90°C Lay-in designed main conductor remains continuous Tap parallel or perpendicular to main GP SERIES f�\ NAED CATALOG CONDUCTOR RANGE APPROX.DIMENSIONS[IN) CTN _ `-J J//�I d EST..SHIPPING NUMBER NUMBER MAIN TAP H W L QTY WEIGHT(Ibs) UNIT !// � 13117 GP 2• 2-12 4-12 SOL 7/8 5/8 1"/., 24 1.43 CTN (� ‘,.) ''''''.11r, 13118 GP 10 1/0-2 1/0-12 SOL 1 3/4 1'/. 12 1 19 CTN 13119 GP 250 250-1/0 250-6 1'h. 1'/,. 2'/3= 12 2.54 CTN 13121 GP 350 350-4/0 350-6 1'!,. 1'/. 2'h. 6 2 75 CTN For copper-to-copper, 13122 GP 500 500-350 500-2 1'!. 1'/. 3'/. 6 3 10 CTN copper-to-aluminum, 13123 GP 750 750-500 500-2 2 1'/. 33/. 3 2 5 CTN 'GP2 has slotted screws. - - aluminum-to-aluminum Oxide-inhibitor is recommended for added corrosion protection. 600V 90°C Snap-on insulating covers for use with GP connectors For indoor use only GPC SERIES NAED CATALOG FOR USE WITH APPROX.DIMENSIONS(IN) CTN EST.SHIPPING \ NUMBER NUMBER CONNECTOR COLOR H W L QTY WEIGHT(las) UNIT / ````\\\N\\ 13137 GPC 2 GP2 YELLOW 1'/« 1"/m 1'/. 12 0.46 CTN /////e �`\\\\� \\\\\1\\ 13138 GPC 10 GP1/0 GRAY 1'I. 2'/u 2'/. 6 0 36 CTN /r/ry/f ///7!p\s\\\ `\\\\\\\1 4 13140 GPC 250 GP250 RED 1'/. 2'/. 3'/u 6 0.40 CTN '; p�//////U l n�\\,\\t\ 13141 GPC 350 GP350 YELLOW 1'/. 3'/,. 33/. 3 0.42 CTN �,' i� impoi 13142 GPC 500 GP500 BLUE 2'/u 3'/,. 4'/. 3 0.46 CTN �ll 13134 GPC 750 GP750 ORANGE 2"/a 3'/,. 4'/. 3 0 65 CTN III www.greaves-usa.com 11 Heritage Park,Clinton,CT 06413•Phone 860-664-4505•Fax 860-664-4546 TOLL FREE 1-800-243-1130(Outside CT) Town of Montville Building Department CONSTRUCTION PERMIT APPROVAL Applicant Is responsible for obtaining ell of the re.uired a.+royals. No .ermit will be issued until all t e re•uired si.natures are obtaipsd. ZS Ph e ctacin`- Property Address Root rrIouh I--P_� S c 1 a r-- P ' S` �-e�v✓x Job Oescri n Required Department Permit Issuance Approval Approval Tax Collector lj /Z/ /l Signature/date Comments: Planning &Zoning Signature/date • Comments: • Fire Marshal Signature/date Comments: ❑ Health Department Rearuired for properties with,privates sepfic or well Comments: WPCA, Administrative d �1�Q� e Usti 04/511,C Required for properties on sewet Signature/date Comments: ❑ WPCA, Operations When Required by WPCA Signature/date Comments: ❑ Department of Public Works Required when project includes drivewvay work or certain dm.iaage requirements Signature/date Comments: ❑ Montville Police Department Re.uired for all•ermits EXCEPT one and two famil residential Signature/date Comments: ❑ State Dept. of Transportation Required for Structures over 100 000 so ft or with mare than 200 parking spaces-Official Copy of SIC Certificate of Operation required—per CGS 19-311 Signature!date Building Department Review Complete _ Signature!date Rmi a'May 23,20U • Ai ilia Ili II SOLAR 611 West Johnson Ave. Cheshire, CT 06410 CT El Lic#124054 Phone:(203)701-3724 Fax:(203)687-4205 Authorization to Apply for ELECTRICAL PERMIT The bearer of this letter is authorized as an agent of TRINITY SOLAR to sign for the following ELECTRICAL PERMIT. (Sec.20-338b) Today's Date: Job Start Date: / '� /2016 Municipality where work shall be performed Mon+V I I1 e_ , Cr Job Name 1,►nd a Cab-e-I S Job Address 25 Pheasaln 1- l iw- O ctKdat-P ('r Description of Job Solar PV Roof Mounted System Name of Authorized Agent man Sa hrloY VP-IernLA,r c Name of Licensed Contractor: Michael A.Mazzamurro CT License/Reg No: ELC.0124054-E1 �A Signature of Licensed Contractor "4„41::, \ •`—" Comments Electrical wiring per the current NFPA 70-NEC 2011 Sec.20-338b.Building permit applications.Who may sign.Any licensed contractor who seeks to obtain a permit from a building official may sign the building permit application personally or delegate the signing of the building permit application to an employee,subcontractor or other agent of the licensed contractor,provided,the licensed contractor's employee,subcontractor or other agent submits to the building official a dated letter on the licensed contractor's letterhead,signed by the licensed contractor,stating that the bearer of the letter is authorized to sign the building permit application as the agent of the licensed contractor.The letter shall not be a copy or a facsimile,but shall be an original letter bearing the original signature of the licensed contractor.The letter shall also include:(I)The name of the municipality where the work is to be performed;(2)the job name ora description of the job;(3)the starting date of the job;(4)the name of the licensed contractor;(5)the name of the licensed contractor's agent;and(6)the license numbers of all contractors to be involved in the work.20 Trinity V)! R HOMEOWNERS AUTHORIZATION FORM 1, Linda Kabelis (print name) am the owner of the property located at address: 25 Pheasant Run (print address) I hereby authorize Trinity Solar, and their subcontracting company , to act as my Agent for the limited purpose of applying for and obtaining local building and other permits from the Authority Having Jurisdiction as required for the installation of a Photovoltaic System located on my Property. This authorization includes the transfer/re-administering, and/or cancellation of any existing permits on file for the purpose of updating/applying with an alternate subcontractor. Customer Signature: Lvvotet Date: 11 /11 /15 Print Name: Linda Kabelis Optimize Engineering Co., LLC P.O. Box 264•Farmville•VA 23901 Ph: 434.574.6138•E-mail: grichardpe@aol.com Richard B. Gordon, P.E. President November 30, 2015 Oakdale Building Department Oakdale, CT Re: Solar Panels Roof Structural Framing Support To Whom It May Concern: I hereby certify that I am a Licensed Professional Engineer in the State of Connecticut. Please note the following conclusions regarding framing structure, roof loading, and proposed site location of installation: 1. Existing roof framing: Roof 1 -2: Truss framing 2x4 at 24" o.c.with 13'-4"& 15' span (horizontal truss projection)at roofs 1 -2, respectively. This existing framing structure below the residence roof is definitely capable for this photovoltaic project. 2. Roof Loading • 4.33 psf dead load (modules plus all mounting hardware) • 30 psf min. live load (per 2005 CT Code Supplement) • 7 psf dead load (2 roof shingle layers and 2 layers wood sheathing) • Exposure Category B, 110 mph wind uplift live load of 17.89 psf(wind resistance) 3. Address of proposed installation: Residence of Linda Kabelis, 25 Pheasant Run, Oakdale, CT 06370 This installation design is in general conformance to the manufacturer's specifications, and will be in compliance with all applicable laws, codes, and ordinances, and specifically International Residential Code/ IRC 2009, 2011 NEC, and 2009 ICC Energy Code. The spacing and fastening of the Unirac mounting brackets is to have a maximum of 64" o.c. span along the rail between mounting brackets and secured using 5/16" x 3 1/2" length corrosive resistant steel lag bolts. In order to evenly distribute the load across the roof rafters, there shall be a minimum of 2 mounting brackets per rafter&min. 2" penetration of lag bolt per bracket, which is adequate to resist all 110 mph wind live loads including wind shear. The mounting brackets shall alternate between adjacent rafters between rail rows for better distribution of roof load. Penetration of anchors for modules mounted within 18" of ridge and edges of roof is to be a minimum of 3". Rails may be attached to either of two mounting holes in the L-feet. Mounting in the lower hole for a low profile, more aesthetically pleasing installation or mount in the upper hole for a higher profile to maximize airflow under the modules to cool them more. Slide the 3'8-inch mounting bolts into the footing bolt slots. The rails will be attached to the footings with the flange nuts. Very truly yours, Optimiz• Enq -eri j• Co, • Richard B. Gordon, P.E. Connecticut P.E. License No. 26357 \•��OF V • 7� • 0�' * ' ,4e 0 26357 ;�$ PoF, /CENS -'����` FSS/ON/ �?��. AC SOLAR To Whom It May Concern, Once this job has passed we would like to request a Certificate of Compliance. (An inspection report officially showing that the job has passed its final inspection.) You may fax to the "attention of" or email the COC to: Avrielle Noble F: (203) 687-4205 W: (203) 701-3724 x1111 avrielle.noble@trinitysolarsystems.com CC: gilda.migliore@trinitysolarsystems.com Any questions, please feel free to contact us. Thank You, Permitting Department Job Address: ZS Phe0.Sctr kkA.r. Connecticut Office 611 West Johnson Avenue Ph:203.701.3724 Cheshire, CT 06410 Fax:203.687.4205 Made with Earth-Friendly Products www.Trinity-Solar.com Optimize Engineering Co., LLC P.O. Box 264•Farmville•VA 23901 Ph: 434.574.6138•E-mail: grichardpe@aol.com Richard B. Gordon, P.E. President November 30, 2015 Oakdale Building Department Oakdale, CT Re: Solar Panels Roof Structural Framing Support To Whom It May Concern: I hereby certify that I am a Licensed Professional Engineer in the State of Connecticut. Please note the following conclusions regarding framing structure, roof loading, and proposed site location of installation: 1. Existing roof framing: Roof 1 -2: Truss framing 2x4 at 24" o.c. with 13'-4"& 15' span (horizontal truss projection)at roofs 1 -2, respectively. This existing framing structure below the residence roof is definitely capable for this photovoltaic project. 2. Roof Loading • 4.33 psf dead load (modules plus all mounting hardware) • 30 psf min. live load (per 2005 CT Code Supplement) • 7 psf dead load ( 2 roof shingle layers and 2 layers wood sheathing) • Exposure Category B, 110 mph wind uplift live load of 17.89 psf(wind resistance) 3. Address of proposed installation: Residence of Linda Kabelis, 25 Pheasant Run, Oakdale, CT 06370 This installation design is in general conformance to the manufacturer's specifications, and will be in compliance with all applicable laws, codes, and ordinances, and specifically International Residential Code/ IRC 2009,2011 NEC, and 2009 ICC Energy Code. The spacing and fastening of the Unirac mounting brackets is to have a maximum of 64" o.c. span along the rail between mounting brackets and secured using 5/16" x 3 1/2" length corrosive resistant steel lag bolts. In order to evenly distribute the load across the roof rafters, there shall be a minimum of 2 mounting brackets per rafter&min. 2" penetration of lag bolt per bracket, which is adequate to resist all 110 mph wind live loads including wind shear. The mounting brackets shall alternate between adjacent rafters between rail rows for better distribution of roof load. Penetration of anchors for modules mounted within 18" of ridge and edges of roof is to be a minimum of 3". Rails may be attached to either of two mounting holes in the L-feet. Mounting in the lower hole for a low profile, more aesthetically pleasing installation or mount in the upper hole for a higher profile to maximize airflow under the modules to cool them more. Slide the 3/8-inch mounting bolts into the footing bolt slots.The rails will be attached to the footings with the flange nuts. Very truly yours, Optimize Engineering Co., LLC Richard B. Gordon, P.E. - Connecticut P.E. License No. 26357 \\\� / \\ F cONNF ''., O , O B' Gp�Op * 1.sZ * _ 26357 VPCs,4/CENS��'0���� ,/ SS/ NAL y .t, ' 1 [ t t }'�' t .S� 1, , d a r" . . .,.. „,„,. i,,, . ., , .- 4,„,,, , „,,,„L..._,,,,,, ,..„ ,,,,,,,,,,...„",,,,,„,” . . ' STATE OF CONNECTICUT + DEPARTMENT OF CONSUMER PROTECTION Be it known that s • MICHAEL A MAZZAMURRO 194 HILLTOP DR ', r SOUTHINGTON, CT 06489 f i has been certified by the Department of Consumer Protection as a licensed 4. ELECTRICAL UNLIMITED CONTRACTOR • • license #ELC.0124054-E1 Effective: 10/01/2015 . IF Iv " a.41-:- Expiration: 09/30/2016 jr„ A,.tr.A.Harris,Commissioner • • • • • • • • • • • • • • 4, * • • I • • • I • • • • . • • • • • • • . • • • • I • '+.!__".fir_ ear_ _S�4`--�'►—',.*_ l – - 4%.* 'P}_5.tv__11.A!P` SP__'t-o___'_ __1X, '_t/i-__"A.-A!..:__4 1___14Lp 41 AP r STATE OF CONNECTICUT + DEPARTMENT OF CONSUMER PROTECTION ; ' ! (4• Be it known that i ' TRINITY HEATING & AIR INC `0 611 West Johnson Avenue ,, Cheshire, CT 06410 . At <ii: is certified by the Department of Consumer Protection as a registeredrI tt:ifi_ HOME IMPROVEMENT CONTRACTORit I Registration # HIC.0635520I-. it I Effective: 12/01/2015 A w Expiration: 11/30/2016 0 4:1_-_. .v ) )•. .,t1..,•A.Ifatris,Commissioner • j _ • • • • • • • • • • • 4 • • • • • • • • ,• `L.a. i . i s 4..• •-• •'• Al��a DATE(MM/DD/YYYY) CERTIFICATE OF LIABILITY INSURANCE V 10/28/2015 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED, the policy(ies) must be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT a BarbarHayden NAME: y DITTMAR AGENCY PHONE (732)462-2343 ac,No):(732)780-8414 ANC,No,Exti: 78 Court Street E-MAIL baharien@dittmarinsurance.com P.O. Box 1180 --__ INSURERS)AFFORDING COVERAGE NAIC I Freehold NJ 07728 INSURER A:HDI-Gerling America Insurance Co. INSURED INSURER B:Lloyd's, London I Trinity Heating & Air Inc. , DBA: Trinity Solar INsuRERCNorth River Insurance Co. ,, BPTP Future Holdings, LLC INSURERD: 2211 Allenwood Road INSURERE: Wall Twp NJ 07719 INSURERF: COVERAGES CERTIFICATE NUMBER:2015-16 Liab Master REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT. TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR --- ADDL SUBR - --_--- _ -_-- -------- POLICY EFF POLICY EXP LTR TYPE OF INSURANCE INSD WVD POLICY NUMBER (MMIDDIYYYYI IMMIDD/YYYYI LIMA X COMMERCIAL GENERAL LIABILITY 2,000,000 EACH OCCURRENCE $ A CLAIMS-MADE X OCCUR PRTO RENTED -- PREEMMISSES(Ea occurrence) $ 500,000 EGGCC000065615 11/1/2015 11/1/2016 MED EXP(Any one person) $ _ PERSONAL&ADV INJURY S 1,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $ 2,000,000 X POLICY - PRO- fl JECT LOC PRODUCTS-COMP/OP AGG $ 2,000,000 OTHER Employee Benefits $ 1,000,000 AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT S 2,000,000 (Ea accident) A X ANY AUTO BODILY INJURY(Per person) $ ALL OWNED SCHEDULED EAGCC000065615 11/1/2015 11/1/2016 BODILY INJURY(Per accident) $ AUTOS AUTOS NON-OWNED PROPERTY DAMAGE $ HIRED AUTOS AUTOS (Per accident) Lease/Loan Gap $ A UMBRELLA LIAB OCCUR EXAGC000065615 11/1/2015 11/1/2016 EACH OCCURRENCE $ 3,000,000 B x EXCESS LIAB CLAIMS-MADE AGGREGATE $ 3,000,000 DED RETENTIONS BINDER110115 11/1/2015 11/1/2016 Limit x of$3,000,000 S 21,000,000 WORKERS COMPENSATION PER OTH- AND EMPLOYERS'LIABILITY Y/N STATUTE ER ANY PROPRIETOR/PARTNER/EXECUTIVE E.L.EACH ACCIDENT $ 1,000,000 OFFICER/MEMBER EXCLUDED? N I A — A (Mandatory in NH) EWGCC000056515 11/1/2015 11/1/2016 E.L.DISEASE-EA EMPLOYEE $ 1,000,000 If yes,describe under _---- - -- - - - DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ 1,000,000 B Errors & Omissions PGIARK0201403 5/30/2015 5/30/2016 Per Occurrence $2,000,000 Pollution Liability Aggregate $2,000,000 DESCRIPTION OF OPERATIONS/LOCATIONS I VEHICLES (ACORD 101,Additional Remarks Schedule,may be attached if more space is required) Re: Trinity location - 611 West Johnson Ave. , Cheshire, CT. 06062 CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE Trinity Heating & Air Inc THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN 2211 Allenwood Rd. ACCORDANCE WITH THE POLICY PROVISIONS. Wall Twsp, NJ 07719 AUTHORIZED REPRESENTATIVE Barbara Hayden/BAH _____,-z.....- _G.- ,....-s%< ,--. -----------,--7-: ©1988-2014 ACORD CORPORATION. All rights reserved. ACORD 25(2014/01) The ACORD name and logo are registered marks of ACORD INS025(201401)