Loading...
HomeMy WebLinkAboutSFR Heating and A/C Fireplace - throat inspection and final Gas Line test Pool bonding and electrical prior to covering Final inspection for Certificate of Occupancy Town of Montville BUILDING DEPARTMENT 310 Norwich-New London Tpke. Uncasville, Ct. 06382 Tel. 848-7166 Fax 848-7231 Permit No: H99-48 Code: 06 Owner: D'Amato Brothers Mailing Address: Quarry Road City: Milford State: CT Zip: 06460 Tel: (203)874-5992 Job Location: 18 Pheasant Run Map/Block-Lot: Contractor: Viglione H&C Mailing Address: 259 Commerce Street City: East Haven State: CT Zip: 06512 Tel: (203)467-8388 Type of Permit: Heating & Air Conditioning Job Description/Materials: Oil warm air heat with a/c. Size: Type of Heat: Warm air Use: Dwelling AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAk**kAAAAAAAAAAAAAAAAAAAA*AAAAk**AAAAAAAAAA Construction Value Fee Building $: $: Plumbing $: $: Heating S: $: Electrical $: $: Air Conditioning$: $: Other $: $: Certificate of Occupancy $: $: Plan Review $: $: State Ed ucation Fee $: Total_$: Inc. wit Bldg. '- -git $: y-- / ,iii-i-'z=T-7(1 ,-.,-er..,,, /7,%5:(A;7 Building Officia Ignature Date AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAkAAAAAkAAAAA k*AAAAAAAA*kA*AAAAAAAAAkAA*AAAAAAA Required Inspections Footings prior to pouring concrete Footing Drains/damp proofing prior to backfi l l Framing Town of Montville Building Department 310 Norwich-New London Tpke. , Uncasville, Ct. 06382 Tel . 848-7166 ***************************************************************************** APPLICATION FOR BUILDING PERMIT OR TRADES PERMIT, Please fill out completely Owner: -9'Amat 6`05 . Mailing Address: POC.(rC' PO ad City: 1 I g-O(C, State: I Zip Code 0(04(00 Tel : a43 Job Location: 1g Phe(rcirit- P.U11 Map/Block/Lot: Contractor: '1, " 1 111 ' 'J'• 44 1f I1 ( ailing Address: 5Q Commerc , S4-. City: `5 fk Ver\ State: L. I Zip Code: laoSID. Tel : p)03-46 l -8388 ****************************************************************************** Stick Built : )C Modular Home: Manufactured Home: Commercial : Addition: Garage: Car Port : Shed: Remodeling: Roofing: Siding: Fireplace: Chimney: Windows: Pool : `Demolition: Plumbing: Heating: 10 Electrical : Air Conditioning: 3C Gas: Patio: Porch: Deck: Retaining Wall : New: Repair/Replacement: Job Discription/Materials used: 0\ 1 warm air reat W ►*h ac Size: Type of Heat: Warm at ( Fireplace: No.of Stories: 02. No. Rooms : C/ Breezeway: No. Baths : Garage: \/€-S Use: d AN2,4(()q I hereby certify that the proposed work will conform to the Basic J Building Code and all other Codes as adopted by the State of Connecticut, and the Town of Montville and further attest that the proposed work is authorized by the owner in fee and that I am authorized to make application for a permit for such work as described above. J / Owner/Agent Signature (/ Date ( I-S If signed by Contractor, type of license/registration & No: 30a3$D Si ****************************************************************************** Building Department Use Only Construction Value Fee Building A to Plumbing Heating Electrical 12 Air Cond. * 1 Other Certificate of Occupancy AIM Plan Review Fee State Education Fee Total Fees Cash/Check :dE •HTG & CLG, INC. , PROJECT: G• :' 1.53-6"S1; --r-r- € COMMERCE DRIVE CLIENT: DAMATO BROS i HAVEN, CT 06512 DATE: 05/17/99 {ESIDENTIAL/LIGHT COMMERCIAL HVAC LOADS DESIGNER: STEVE VIGLIONE CLIENT INFORMATION: NAME: nAMATO BROS ADDRESS : CITY, STATE: MONTVILLE CONN TOTAL BUILDING LOADS : BLDG. LOAD AREA SEN. LAT. + SEN. = TOTAL DESCRIPTIONS QUAN LOSS GAIN GAIN GAIN 3-C WINDOW DBL PANE CLR GLS METL FR 156 9, 048 0 4, 125 4, 125 12-I WALL R-19 +1/2"ASPHLT BRD (R-1 . 3) 1, 573 6, 922 0 2, 042 2, 042 j 11-C DOOR METAL POLYSTYRENE CORE 63 2 , 369 0 699 699 16-G CEILING R-30 INSULATION 768 2 , 028 0 1, 115 1, 115 1 19-A FLOOR/ENCL CRAWL HARDWD NO INS 1, 536 19, 170 0 0 0 SUBTOTALS FOR STRUCTURE : 4, 096 39, 537 0 7, 981 7, 981 PEOPLE 8 0 1, 840 2 , 400 4, 240 I APPLIANCES 0 0 0 1, 200 1, 200 DUCTWORK 0 5, 396 0 670 670 INFILTRATION W.CFM: 163 . 8 S . CFM: 81 . 9 0 14, 418 2 , 284 1; 802 4, 086 VENTILATION DJ.CFM: 61 . 4 S . CFM: 61 .4. 0 5, 407 1, 713 1, 352 3, 065 SENSIBLE GAIN TOTAL FEMP. SWING MULTIPLIER 15, 405 X 1 . 00 3UILDING LOAD TOTALS 64, 758 5, 837 15, 405 21, 242 LOAD SUMMARY FOR ZONE #1 ;UPPLY CFM AT 91 . 20 DEG HTG DT: 328 CFM PER SQUARE FOOT: 0 . 427 ;QUARE FT. OF ROOM AREA: 768 SQUARE FOOT PER TON: 821 . 976 'OTAL HEATING REQUIRED WITH OUTSIDE AIR: 35 . 615 MBH TOTAL COOLING REQUIRED WITH OUTSIDE AIR: 0 . 934 TONS i LOAD SUMMARY FOR ZONE #2 UPPLY .CFM AT 70 DEG HTG DT: 343 CFM PER SQUARE FOOT: 0 .447 QUARE FT. OF ROOM AREA: 768 SQUARE FOOT PER TON: 919 . 027 OTAL HEATING REQUIRED WITH OUTSIDE AIR: 29 . 142 MBH OTAL COOLING REQUIRED WITH OUTSIDE AIR: 0 . 836 TONS . ,w�. - 1 /24 ,P RESIDENTIAL AND LIGHT COMMERCIAL HVAC LOADS BY ELITE SOFTWARE ******* /,.ONE HTG & CLG, INC. EAST HAVEN, CT 06512 , REL 1536 SQ FT 05/17/99 PAGE 2 *********t************* BUILDING LOADS (CONTINUED) ************************* TOTAL BUILDING LOAD SUMMARY 3UPPLY:CFM AT 80 .40 DEG HTG DT: 671 CFM PER SQUARE FOOT: 0 .437 3QUARE FT. OF ROOM AREA: 1, 536 . SQUARE FOOT PER TON: 867 . 715 DOTAL HEATING REQUIRED WITH OUTSIDE AIR: 64 . 758 MBH rOTAL COOLING REQUIRED WITH OUTSIDE AIR: 1 . 770 TONS 2ALCULATIONS ARE BASED ON 7TH EDITION OF ACCA MANUAL J. ALL COMPUTED RESULTS ARE ESTIMATES AS BUILDING USE AND WEATHER MAY VARY. BE SURE TO. SELECT A UNIT THAT MEETS BOTH SENSIBLE AND LATENT LOADS . • _ '* RESIDENTIAL AND LIGHT CQMMERC�`.?NL HVAC LOADS BY ELITE SOFTWARE ******* 4 JNE HTG & CLG, INC. x EAST HAVEN, CT 06512 ,REL 1536 SQ FT 05/17/99 PAGE 3 x********************** ZONE # 1 ROOM LOAD SUMMARY ************************* M ROOM AREA HEATING COOLING O. DESCRIPTION (SF) BTUH o TOT CFM BTU} o TOT CFM • L 1 . WHOLE FIRST FL 768 32 , 912 100 . 0 374 7, 217 100 . 0 - 328 ;ONE SUBTOTAL 768 32 , 912 100 . 0 374 7 , 217 100 . 0 328 'ENTILATION 2 , 703 676 ,ATENT GAIN 3 , 319 ;ONE TOTALS 35, 615 11, 212 0 . 934 TONS .******* RESIDENTIAL AND LIGHT COMMERCIAL HVAC LOADS BY ELITE SOFTWARE ******* IIGLIONE HTG & CLG, INC . EAST HAVEN, CT 06512 ;AMBREL 1536 SQ FT 05/17/99 PAGE 4 ************************ ZONE # 2 ROOM LOAD SUMMARY ************************* 2M ROOM AREA HEATING COOLING O . DESCRIPTION (SF) BTUH o TOT CFM BTUH TOT CFM 2 . WHOLE SECOND FL 768 26, 439 100 . 0 343 6, 836 100 . 0 343 ZONE SUBTOTAL 768 ' 26 , 439 100 . 0 343 6, 836 160 . 0 343 VENTILATION 2 , 703 676 LATENT GAIN 2 , 516 4• ZONE TOTALS ' 29 , 142. 10, 028 0 . 836 ,TONS • • i 2/ , , /` HTG . & CLG, INC. PROJECT: RANCH 1550 SQ FT COMMERCE DRIVE CLIENT: DAMATO BROS / HAVEN, CT .06512 DATE: 05/07/99 DENTIAL/LIGHT COMMERCIAL HVAC LOADS DESIGNER: STEVE VIGLIONE / 7 CLIENT INFORMATION: NAME: nAMATO BROS ADDRESS : RD CITY, STATE: MONTVILLE CONN • TOTAL BUILDING LOADS : BLDG. LOAD • AREA SEN. LAT. + SEN. . TOTAL _ DESCRIPTIONS QUAN LOSS GAIN GAIN GAIN 3-C WINDOW DBL PANE CLR GLS METL FR 153 8, 874 0 3 , 960 3, 960 12-I WALL R-19 +1/2"ASPHLT BRD (R-1 . 3) 1, 221 5, 373 0 1, 584 1, 584 _ 11-A DOOR METAL FIBERGLASS CORE 84 3 , 964 0 1, 170 1, 170 16-G CEILING R-30 INSULATION 1, 550 4, 092 0 2 , 251 2, 251 _ 19-F FLOOR/ENCL CRAWL CARPET NO INS 1, 550 13 , 516 0 0 0 SUBTOTALS FOR ' STRUCTURE : 4, 558 35, 819 0 8, 965 8, 965 PEOPLE 4 0 920 1', 200 2, 120 APPLIANCES 0 0 1, 200 0 1, 200 DUCTWORK 0 5, 037 0 599 599 INFILTRATION W.CFM: 165 . 3 S .CFM: 82 . 7 0 14, 549 2 , 305 1, 819 4, 124 VENTILATION W.CFM: 62 . 0 S . CFM: 62 . 0 0 5, 456 1, 729 1, 364 3, 093 SENSIBLE GAIN TOTAL TEMP. SWING MULTIPLIER 13, 947 X 1 . 00 BUILDING LOAD TOTALS 60, 861 6, 154 13 , 947 20, 101 • SUPPLY CFM AT 54 . 80 DEG HTG DT: 919 CFM PER, SQUARE FOOT: 0 .593 SQUARE FT. OF ROOM AREA: 1, 550 SQUARE FOOT PER TON: 925 . 327 TOTAL HEATING REQUIRED WITH OUTSIDE AIR: 60 . 861 MBH TOTAL COOLING REQUIRED WITH OUTSIDE AIR: 1 .675 TONS CALCULATIONS ARE BASED ON 7TH EDITION OF ACCA MANUAL J. ALL COMPUTED RESULTS ARE ESTIMATES AS BUILDING USE AND WEATHER MAY VARY. BE SURE TO SELECT A UNIT THAT MEETS BOTH SENSIBLE AND LATENT LOADS . • e s tv,: AESIDENTIAL 'AND LIGHT COMMERCIAL HVAC LOADS BY ELITE SOFTWARE ******* /HTG & CLG, INC. EAST HAVEN, CT 06512 ,1550 SQ FT 05/07/99 PAGE 2 ******************* ZONE # 1 ROOM LOAD SUMMARY ************************* 14 ROOM AREAHEACOOLING NO— DESCRIPTION (SF) BTUH TOTG CFM BTUH o TOT CFM 1. RANCH 1550 . SQ FT 1, 550 55, 405 100 . 0 919 12, 583 100 . 0 919 • ZONE SUBTOTAL 1, 550 55, 405 100 . 0 919 12, 583 100 . 0 919 VENTILATION 5, 456 1, 364 LATENT GAIN • 6, 154 ZONE TOTALS- 60, 861 20, 101 1 . 675 TONS • • fA • ` -__ - •lei" - ...._.