Loading...
HomeMy WebLinkAboutFurnace 2017 TOWN OF MONTVILLE Building Department 310 NORWICH-NEW LONDON TURNPIKE UNCASVILLE, CT 06382-2599 TEL. (860) 848-3030 X382 FAX. (860) 848-7231 MECHANICAL PERMIT Permit Number: M2017-0131 Date: 31-Jul-17 Map/Lot: 028/005-065 Owner ID: 5454000 Project Location: 2 PHEASANT RUN Unit: Job Description: Replace Oil Furnace Owner Nam Timothy C and Carolyn A Featherstone Tenant Name N/A Careof: 2 Pheasant Run Oakdale CT 06370- Telephone: (860)772-7735 Applicant Name Richard M.Johnson Jr. Telephone: (800)815-1128 DBA: DDLC Energy Lic/Reg Type S Lic/Reg N 303006 243 Timber Trail Exp Date: 31-Aug-17 East Hartford CT 06118- Construction Value Permit Fees Construction Information Building Value: $0.00 Building Fee: $0.00 Use Group: IRC Plumbing Value: $0.00 Plumbing Fee: $0.00 Code: 2016 State Building Code Mechanical Valu $4,789.00 Mechanical Fe $60.00 Electrical Value: $0.00 Electrical Fee: $0.00 Construction Type IRC Total Value: $4,789.00 Penalty Fee: $0.00 Permit Code: R5 C of 0 Fee: $0.00 Comment Plan Review Fe $0.00 State Ed Fee: $1.25 Total Fee Paid: $61.25 It shall be the owners repsonsibility to schedule the following inspections a minimum of 2 business days in advance: Field set of approved construction documents shall be available onsite during all inspections. BUILDING PERMIT INSPECTIONS PLUMBING,MECHANICAL, ELECTRICAL PERMIT INSPECTIONS ❑ Footing-Prior to pouring concrete ❑ R Plumbing and leak test ❑ Deck Piers ❑ R Electrical ❑ Backfill-Footing drains and waterproofing ❑ Elec Trench-with conduit installed ❑ Concrete Slab-Prior to pouring concrete ❑ Pool Bonding ❑ Anchor Bolts-with sill plate and prior to floor frami ❑ Electrical Service CRS No: (1 ❑ Framing ❑ R HVAC ❑ Masonry Fireplace Throat or Chimney Thimble ❑ Gas Piping and leak test ❑ Fireblocking Draftstopping INSPECTION REQUIRED UPON COMPLETION ❑ Insulation 0 Certificate • ppr. al P ertif-at off, cupancy Building Official's Approval: / / I own oz lviontviLte Building Department 310 Norwich-New London Tpke. Tel. 860-848-3030, Ext 382 Uncasville, CT 06382 Fax. 860-848-7231 PERMIT APPLICATION FORM Permit No. 7-D1.3t Type of Work Occupancy Classification Construction Type Permit Type ❑ New Construction ❑A-1 ❑B ❑ H-1 ❑ 1-1 ❑ R-1 ❑S-1 ❑Type IA ❑Type IIIB ❑ Building ❑Addition ❑A-2 ❑ B,Medical ❑ H-2 ❑ 1-2 ❑ R-2 ❑S-2 ❑Type IB ❑Type IV PP umbing ❑Alteration ❑A-3 ❑E ❑ H-3 ❑ 1-3 ❑ R-3 ❑ U ❑Type IIA ❑Type VA I Mechanical ❑Change of Use ❑A-4 ❑F-1 ❑ H-4 ❑1-4 ❑ R-4 ❑ Mixed ❑Type IIB ❑Type VB ❑ Electrical ❑A-5 ❑F-2 ❑MLI Type IIIA CRS#: Property Address: 2 r°V�RSCNtN� 9--k. n (Number) (� (Street) (Unit) Job Description: Q- C,CA `J (—v c-nc^CA_, in bh312-Yv,,,,,, t„rt.Or\ Tr nr-t- gQ Owner: ( i r " I SS6 ^Q- Tenant: r^(\�Address:- „ Address: City/State/Zip: ^ k-dP , C,7 / City/State/Zip: Telephone('61 0 ) L�� - 1 J Telephone( ) - Applicant: DBA: IP i�M 5--c..r V C..Q-_.5 r1 (3G-NI City N4t-(1 State: Ct Zip Code:Oji h (t Telephone(24 3 -)q� \ - ()(-11-10 Contractors - Complete the Following: License/Registration Type: License/RegistrationNo.:Q3C)3QOG-S(Expiration Date: T./31/ 3I� I hereby certify that the proposed work will conform to the State Building Code and all other codes as adopted by the State of Connecticut and the Town of Montville and further attest that the proposed work is authorized by the owner in fee and that I am authorized to make application for a permit for such work as described above. Owner Agent ignature: Date: 11,5i Construction Value Permit Fees Building Value: Building Fee: Plumbing Value: Plumbing Fee: Mechanical Value: "-1 Mechanical Fee: Le() — Electrical Value: Electrical Fee: Total Value: Penalty Fee: C of 0 Fee: Plan Review Fee: State Ed Fee: I _07 S Total Fee: (C ( .<3 5 Revised August 23,2007 Town of Montville Building Department File Receipt Date: 31-Jul-17 ReceiptNo: 12513 Received From: Connecticut Permit Services.LLC Job Address: 2 Pheasant Run Town Fees Collected State of Connecticut Fees Collected Bldg Cash: 50.00 State Cash: 50.00 Bldg Check: 561.75 State Check: 51.25 Bldg Credit: 50.00 State Credit: 50.00 Fire Cash: 50.00 Fire Check: 50.00 Fire Credit: 50.00 Construction Value: 54.789.00 Demolition Value: 50.00 CheckNo: 25404 Received By: David Jensen .6 .4 �% Court 2 Pheasant Run ITEM QTY $/UNIT TOTAL Building Plumbing Mechanical Electrical BUILDING AREA Basement,Finished SF $ 41.96 $ - $ _ Interior Renovations SF $ 36.09 $ - $ - $ _ AMENITIES Kitchen EA $ - $ _ $ Full Bathroom EA $ _ $ _ Half-Bathroom EA $ - $ _ GARAGE Detached SF $ 71.53 $ - $ _ MECHANICAL Warm-Air n Y/N $ - Hot Water n Y/N $ - Electric n Y/N $ Air Conditioning n Y/N $ - ELECTRICAL SERVICE Upgrade Amps $ _ Subpanel EA $ 699.00 $ _ Gen Set EA $ 3,850.00 $ _ SOLID FUEL BURNING APPLIANCES Prefab Metal Fireplace EA $ 6,497.70 $ - Masonry w/lfireplace EA $ 7,096.65 $ - Masonry w/2 fireplaces EA $ 11,095.70 $ - Wood Stove,free standing EA $ 2,692.25 $ - Wood stove insert EA $ 1,859.77 $ - DECKS,PORCHES,SUNROOMS Deck SF $ 44.07 $ - Porch SF $ 149.38 $ - Sunroom SF $ 176.90 $ - $ POOLS&HOT TUBS Hot Tub EA $ 8,016.25 $ - $ _ Inground Pool EA $ 31,550.00 $ - $ Above Ground Round EA $ 6,299.46 $ - $ _ Above Ground Oval EA $ 7,019.75 $ - $ Pool Heater EA $ 8,984.25 $ - $ - Inflatable Type Pool EA $ 1,200.00 $ - $ _ SHEDS w/o electrical SF $ 25.55 $ - w/electrical SF $ 26.85 $ - $ _ RENOVATIONS Roofing,Overlay SF $ 3.50 $ - Roofing,Strip&reroof SF $ 4.50 $ - Roof Sheathing SF $ 1.51 $ - Siding SF $ 6.75 $ - Windows EA $ 550.00 $ - Skylights EA $ 1,051.10 $ - Doors,Exterior EA $ 601.50 $ - Oil Tank,275 Gallon EA $ - Oil Tank,550 Gallon EA $ - MISCELLANEOUS CALCULATIONS $ 4,789.00 Solar Install n TOTALS $ - $ - $ 4,789.00 $ - PERMIT FEE CALCULATIONS Construction Value Fee Building $ _ $ _ Plumbing y $ _ $ _ Mechanical y $ 4,789.00 $ 60.00 Electrical y $ $ _ Plan Review Fee y $ _ Certificate of Occupancy Fee $ _ Plan Review Fee $ State Education Fee $ 1.25 TOTALS $ 4,789.00 $ 61.25 Figures are based on the 2006 RS Means Residential Cost Data • Eft J114 DDLC 36 Brownstone Avenue, Portland, CT 06480 ENERGY (800) 815-1128 Fax: (860) 342-4455 Date To TOwr\ orrh i\Ac1nk- ATTN: Town Building Inspector Re PERMIT AUTHORIZATION LETTER Dear Sirs: In accordance with Connecticut Statute 20-338B, this letter serves as written authorization and notification that Connecticut Permit Services, Inc. Employee listed below have the authority to represent us in the procurement of permits and pertinent documentation on our behalf as detailed below. Project Start Date fk->iikr Project End Date Project Type: ti Q, \ rV rn.PCR/ Location: ' 1 r‘A,c vj �5� °�- ;'ht 5 h+0-- n �6S10 Authorized Agent Connecticut Permit Services, Inc. Service Agent name Very truly Yours, Licensee Signature L Printed Name Richard Johnson License Number 51-303006 Notary Public Printed Name OPaOVtairklc My Commission Expires 1 V5I\\Le Notary Public Signature 4CM\KU Heather M. Dutton NOTARY PUBLIC My Commission Expires January 31,2016 • • W. i • ,ago' v ,1,-&.;.;: 1 - ;, �i v �? �i•� S kit.- �1 '.�`f 't�dl{t p •AAA:- �.Y•i�` f'd• "7 VY' ,J(��� � 1. 7I n I '•, •"�..,. ______._ t'1 • - i .,-• •-?..-.„.:?, ' L) 0 ' a) I =� z . .t.„ , . ._,),...., Vit. O ,..,,,, ,.__. • ,-..„..,:„. • l':"OLA ,---, a' C.) . . - V-ize4 'fc IS r:4 m U � TA'-'i? . ` ., oWcn jj, ® re •77.4 : L.1 Ci)1 1--� 0 )--•I Cr) 11:%% h:40., R O N V... fyr-c chip CD •'� cel ( ' .N �' (� W 1. 17-�% U �, }.--i c• co 1 '-:• r.-.1 •Q, l"S Q 4 1 -"A ®• ,�• 'Pfi V a 1 W ; 1 .• { �� •-.moi it CI) :a I \" . " . nj •`.� '` �.r• 2 • ?`\ •��?`��. �:Ty�`(t. • .. .r•'.I4'a JL �A�` _;=\(`l'•' P;E• AR® CERTIFICATE OF LIABILITY INSURANCE DATE(61MIDD/YYYY) 0/26/2016 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT NAME: PG Genatt Group LLC PHONE FAIC,u.):1-516-470-0338 3333 NEW HYDE PARK RD ok/C,No.E.n:516-869-8788 1( SUITE 409 ADDRESS: • NEW HYDE PARK NY 11042 INSURER(S)AFFORDING COVERAGE I NAIC S usuRERA:First Merc Jry inS)ran e omDan 110657 INSURED INSURER B:Trans_portation Insurance Co. 20494 Hop Energy LLC INSURER C:Valley Forge i0505 DDLC Energy INSURER D:Travelers Property Casualty Co.of I 4 West Red Oak Lane White Plains NY 10604 INSURER E:Lexington Insurance Company 119437 INSURER F: COVERAGES CERTIFICATE NUMBER:1741436287 REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. 'LTR I TYPE OF INSURANCE I INSR I VNO I POLICY NUMBER 1 If dIDDnYYYI I)I8 MODIYYY)I LIMITS A [GENERAL LIABILITY MACGL000001890605 10/27/2016 10/27/2017 EACH OCCURRENCE 51,000.000 1X I COMMERCIAL GENERAL LIABILITY DAMAGE TO REN E s I PREMISES En occurrence 1 550,000 I (I 1 CLAIMS-MADE IX I OCCUR MED EXP(Any one person) S IX SIR S100,000 PERSONAL 6 ADV INJURY 51.000.000 — GENERAL AGGREGATE 152.000,000 GENT_AGGREGATE LIMIT APPLIES PER: PRODUCTS-COMP/OP AGG 152,000,000 I POLICY 1 I jE C [1 LOC 15 B I AUTOMOBILE LIABILITY 10/27/2016 10/27/2017 .OM81NcU SINGLE�IMII BUA2098344188 IEa accidenp I$1,000,000 ANY AUTO BODILY INJURY(Per person) 15 ALL OWNED AUTOS SCHEDULED BODILY INJURY(Per accident) 5 AUTOS HIRED AUTOS NON-OWNED PROPERTY DAMAGE AUTOS (Per accident) 5 S E IX I UMBRELLA LIAR r OCCUR 015375083 10/27/2016 10/27/2017 I EACH OCCURRENCE 154,000,000 EXCESS LIAR l CLAIMS,MADE I AGGREGATE 154,000,000 DEO IX I RETENTION S10,000 I IS C WORKERS COMPENSATION WC2098344093 10/27/2016 10/27/2017 X I WC STATU- Ix IOTH- D AND EMPLOYERS'LIABILITY Y/N 7PJUB5B70389516 10/27/2016 . 10/27/2017 TORYlIMRS ER ANY PROPRIETOR/PARTNER/EXECUTIVE E.L.EACH ACCIDENT 151,000,000 OFFICER/MEMBER EXCLUDED? N/A JJ (Mandatory In NH) E.L.DISEASE-EA EMPLOYEE 51,000,000 If yes,describe under DESCRIPTION OF OPERATIONS below ,E.L.DISEASE-POLICY LIMIT 151,000.000 DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES (Attach ACORD 101,Additional Remarks Schedule,if more space Is required) CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE ©1988-2010 ACORD CORPORATION. All rights reserved. ACORD 25(2010/05) The ACORD name and logo are registered marks of ACORD • Town of Montville • Building Department CONSTRUCTION PERMIT APPROVAL z e � 1L Property Address 22- / fi X �O �7kgr Job Description Required Department Approval Permit Issuance Approval Tax Collector 1/4/A7 ignature/date Comments: Fire Marshal 7/7/4 7 Signature/date Comments: ❑ Planning & Zoning Required for all permits except Signature/date Plumbing,Electrical,Mechanical, Roofing,Siding,Windows&Doors ❑ Health Department Required for properties with private septic or well Signature/date Comments: WPCA, Administrative Di c_4.4c ©f 7/3/// 7 , Required for properties on sewer Signature/date Comments: ❑ WPCA, Operations When Required by WPCA Signature/date Comments: ❑ Department of Public Works Required when project includes driveway work or certain drainage requirements Signature/date Comments: ❑ Montville Police Department Required for all permits EXCEPT one and two family residential Signature/date Comments: ❑ Copy of State Dept. of Transportation Certificate Required for Structures over 100,000 sq.ft.or with more than 200 parking spaces-Official copy of STC Certificate of Operation required—per CGS 14-311 Signature/date Building Department Final Inspection *vicar 2015 I www.AutomaticTIC.com www.CTRefming.ccm trammeC 84 Oakland Ave P.O.Box 8668 HOP-a 888-225-5540 Earl Hartford,CT 06108 New Haven,CT 06531 CT LICA S1 303056,SM7-4448, ( CT LIC#S1-303006,SM1.4448. a P1-202648,RI LICA R14-7946#404C �'1 P1-202648,Al LICA RM-7945 "� ..a,v Fax: 860-271-2050 ENERGY HOD 0 HOD#298 x ;' f eller f QCwww.DOLCEnergy.com410 New London, www.Va7IeyOI.uom DO New Lank oVALLEY 36 Brownstone Ave. G6320 CTPortland,CT 06480 CJ)I)T N LCCA 57-3386,H, #38548, SIL RI IIIA AM.13456, #402 OIL ACCT.NO. ENERGY AlRI LICA PM-3388,HOD#385 RI UCA I-30305,,HODSM A402 xcY INT.ACCT.NO. Applicant Co-Applicant Na e 1 rA Address Address 4,2„ .phr „-/- Pm, City,State,Zip City,State,Zip d JAL. C"---; 61‘376_ _ Email Email Phone# Workir3laone# Cell Phone# Phone# Work Phone# Cell Phone# (P'e"j7) --7731 Payment Options: 0 American Express 0 Discover 0 Master Card 0 VISA 0 Personal Check or Money Order U Bank Check ❑Boiler Qty Model# 0 Oil Tank Qty Model# _ _IN-Furnace/Air Handler Qty__j Model# 0 Humidifier Qty Model# ❑Condenser/Heat Pump Qty____Model# ❑Chimney Liner Qty__Model# 0 Water Heater/Indirect Qty Model# 0 Generator Qty Model# _ ❑A/C Coil Qty_Model# ❑Maintenance Plan _ Exp. __ Scope of work:(attach additional description and/or drawings if necessary) Check box if additional page(s)were used to describe work. 0#pg. c 66+t t e K►S Aj - "L.A.r..n.G_e c i....i itis A- „�t.....: .0+1 i'e;. 4. i- L r•-s. -..-cf,A1A-i �x Y -�--. t'2cs9k'r.!- C-tv ..4-L,: fit ' r ",res ,%k. ,r\�:..i3 s Y� Ilio- Y.. I e,' O r— (•i.A eke cA- J p t= A- ,e1 4y, t .n..t 0+i 1 i to{ r Itis tux- est e t —qvnfacc ,j Zl :in t `,1 CA.1+. ,n,_P- d el ii -rc I e.A.k ir—eky,.J f)rr-tit+il G CfrZ11 flr A aid” Installation may include necessary local tees,licenses and permits relative to this proposal. Replacement of the heating unit will be performed after Asbestos has been removed,at Buyer's THIS QUOTE IS VALID FOR THIRTY DAYS FROM: expense,by a licensed Asbestos removal contractor,and disposed of in accordance with 1.Installation Total Cost $ 1'7 O, government regulations.Price does not include Asbestos removal. (initials) 2 Disposal Fee $ vC Any limitations of existing duct work system is the responsibility of the owner fI (initials) � 3.Total Installation Cost $ Ye �� For valuable consideration received,I/we the undersigned do hereby absolutely and unconditionally ` ��� guarantee,as an lndivldual(s),payment of any indebtedness incurred by virtue of any and all credit 4.Down payment $ extended in accordance with the within agreement and all of its terms and conditions.The undersigned consents to HOP Energy obtaining a Consumer Credit Report on Applicant and/or co-applicant for the pur- pose of evaluating the credit worthiness of applicant and/ or co-applicant, in connection with en 5.Amount Financed $ application of credit. The amount of credit provided to you on your behalf NOTICE TO BUYER: 1.Do not sign this contract before you read it or if it contains any 6.Amount of Monthly Payment $ blank space. 2. You are entitled to a completely filled-in copy of the contract when you sign it. 3. Under the law,you have the following rights,among others: (a)to pay off in ad- 7.Number of Monthly Payments $ vance the full amount due and obtain a partial refund of any unearned finance charge;(b) to redeem the property if repossessed for a default;(c)to require,under certain conditions, (j �� a resale of the property if repossessed.YOU,THE BUYER, MAY CANCEL. 8 The aTotal oun1of Pyou willllale paid when you have $ l THIS TRANSACTION AT ANY TIME PRIOR TO MIDNIGHT OF made all scheduled payments THE THIRD BUSINESS DAY AFTER THE DATE OF THIS Each Payment Due on(date) 30 days after billing TRANSACTION. SEE THE ATTACHED NOTICE OF Payment Schedule Starting on 30 days atter billing CANCELLATION FORM FOR AN EXPLANATION OF THIS 9.Annual Percentage Rate RIGHT. You acknowledge that Seller has delivered or mailed to you an executed copy of as a yearly rate this contract. 10. Finance Charge $ (' Uwe hereby accept the terms and conditions of the proposal as set for the above and on the The Dollar amount the credit will cost you reverse side of the sheet,al .f which I/we t-ve re-^and-gree to be bound thereby. / 11.Total Sale Price $ -9: 7(i7 Applicant 4 J _ %sate ,/ 7/f 7 The total pace of your purchase on credit, 4 including your down payment Co-Applicant Z mss' rte. �Daate,j7/,1-7/0�y Print Name Applicant 0 'a,gat 4e0C[,i.0 ��47ti(r'Sf D'ateC�`47A! Sales Representative Date°7 // Co-Applicant 0 &r/�r't�`Fit j7"T!'`e'-�ft,'p , ,f 4"/r,,Branch Manager Date 9 . HOP Energy SLAM Lead Information Name Timothy Featherstone Interested In Air Conditioning Delivery 2 heasant RunP — x Lead Source Contractor Connect Address Oakdale CT 06370 / Mailer Response Sales Status Credit Approved �UUng--2 Pheasant Run Outside Sales Rep Address Oakdale CT 06370 Inside Sales Rep Branch DDLC Energy Email oehsara@od.com Date Created 07/202017 Phones Homs: 8603670818 Created By mkerrigan Mobile � � Date Updated 07/25/2017 Updated By jgrieco Move Out Date Existing Acct N 0 Attorney Realtor LandLord HD Prospect# HD Lead Gen Employee Ref HDStore# O Svc Tech Ref 0 Promotions Type mva|oe Accouni/Cnadit4op|icotions CreditStatus DateAoproved Approval Conditions EnergvAcot Budget? Budget Start Approved 07/25/2017 N 01/01/1800 Comments Created By mkerrigan Date Created 7/20/17 Updated By mkerrigan Date Updated 7/20/17 Appt Fri 7/21 @5PM 1 Furnace &Air Conditioning Survey Equipment Specialist JEFF GRIECO Branch DDLC Customer's Name TIMOTHY FEATHERSTONE Date 7/27/2017 Customer's E-mail Install Address 2 PHEASANT RUN Customer Contact Numbers City/Town OAKDALE CT Zip 06370 Home# 860-772-7735 Municipality/Township Billing Address SAME Cell# City/Town Zip Work# Account# I Existing Equipment Lo-Boy Hi-Boy X Counter Flow Horizontal #of Zones 1 Make Model Front Flue Rear Flue Humidifer EAC A/C X Size of Smoke Pipe 6 Size of Warm Air Plenum: Length Width Height Size of Cold Air Plenum: Length �.... Width Height Size of Main Hot Air Supply Trunk x Furnace Height OIMONNIMINIMIIINIIII Distance Between Plenums �- Main Cold Air Supply Trunk x Ductwork type Steel Size of Smoke Pipe Size of Chimney Thimble A/C X Chimney Location Chimney Height Power Vented Chimney Type Brick Direct Vent Metal Pre-Fab How Domestic Hot Water is Provided I New Equipment Sold New Unit TRANE FURNACE Front Flue X Rear Flue New Burner BECKETT #of registers Belt Driver Blower Direct Drive Blower X Fresh Air Kit Number of Zones 1 Size of Dampers Control Panel A/C X Humidifier EAC Other Access to building Entry in bulkhead If other Size Floor Covering Required NO Basement Height 8 Area Clear YES Basement Floor Type If other #of steps Does equipment need to be cut to be removed no Special Instructions REUSE OIL LINE. NEW. Date Job Scheduled 8/1/2017 Lead Source(Tech name, Lowes, Date proposal signed 7/27/2017 etc.) CONTACTOR CONNECT Cost Summary Sheet Major Materials Needed Equipment Description Part# Part Cost Qty Total FURNACE 1615 $1,615.00 $0.00 $0.00 $1,615.00 Minor Materials Needed Equipment Description Part# Part Cost Qty Total Minor Materials Needed 50 $50.00 $0.00 $0.00 550.00 Miscellaneous Materials Needed Equipment Description Part# Part Cost Qty Total $0.00 $0.00 $0.00 $0.00 Labor Required Sub Contractor Rate(In house Or In House Labor hours $48/hr) Total to pay to sub Total Sub 900 $900.00 50.00 $0.00 50.00 $900.00 Cost Summary Sales Estimate Actual Variance %Variance Sales Price prior to allowances/rebates Incl $49 Disposal Fee $4,769,00 Service Contract Allowance Other Credits/Rebates Net Sale Price $4,769.00 Major Materials $1,615.00 Minor Materials $50.00 Miscellaneous Materials Labor(In House/sub) $900.00 Permits $150.00 Taxes $106.00 Total Cost $2,565.00 Mark-up used 0.54 Gross Profit $1,631.72 GP% 34.22% Commission% 12.00% Other Information THE STAR SUPPLY COMPANY Quotation 118 Gando Drive P.O. Box 9494 NEW HAVEN CT 06534 {ET:': ::::::>:::A3140MR::::: :i:: 203-772-2240 Fax 203-772-1040 07/27/17 S1897968 ORDER TO: :yq.` ......... -4-- THE STAR SUPPLY COMPANY" �"-""-'"''"- 118 Gando Drive P.O. Box 9494 1 NEW HAVEN, CT 06534 OIOTE TO: SNIP TO: HOP/DDLC ENERGY HOP/DDLC ENERGY 410 BANK STREET 410 BANK STREET NEW LONDON, CT 06320 NEW LONDON, CT 06320 ::::::::::c:�$fE?�IE�?#UME�'Eg.�: �:�:::::>:�:�::<:�:�:� ::G�3QxER�:489.E3�:tntMB£R;::•::::-:;_:::•.::::-.�::::::::::::•. ••::::::•:•:::::::-.:• __•___•_'T:_•__:___>__•>__•_:__•____�__'T:__::_.�:::.::::�::._:::.:.::::::::::...::.:•::::.•::::•:::�Ft�rtSE:.#?fN&E�:;::`: ::;;•::::;•:;<:-;•:::5:>: :�:�:� : :a?c£.f��B£f{StJfl::..::::::::::::.::::• 6425 FEATHERSTONE FURNACE DON WHEELER .._ :. . ., . ..__._..._.,....,.,_..,...._.-:.::._::_.�_:::::.;::�•::::::A:;�:::::•>::::::�::--:>: :-:•::.,.::.-::•::::::3�R2�S::;<-:•:�:•:::-:::�:•::;•:::.::•:::::�ttl±-::RAT£:;o-:;->:•::>:�£:EG83::Ak.kQHFL':.-:: SEAN LYONS OT OUR-TRUCK Net Due 30th Prox 07/27/17 • No i:::;DRPER::47 t: is 5 t:::::::F ATti:H�J::::;: ;:: :::::::;.::•:•: <;•::::• •::•.::• •. :..:....:::::•::: •::::..:................. lea! TRANE THV1C072A948SA OIL FIRED 1615 .67 �RT 1615 .67 LOW PROFILE HIGHBOY FURNACE PSC MOTOR 90, 000 OUTPUT 4 TON DRIVE WITH BECKETT AFG BURNER 4ea GRAY 300 5 X 24 26GA ROUND PIPE 4 .41 17 .63 (ACME 4) 3ea GRAY 302 5 26GA 90DEG ELBOW 2 . 79 8 .37 (ACME 81) lea GRAY 311P 6 X 5 REDUCER 4 . 90 4 . 90 (ACME 65NC) lea STEEL 36X96 (26 GAUGE) SHEET METAL 15 .44 15.44 GALVANIZED TAXES NOT INCLUDED * This is a quotation * Subtotal 1662 .01 Prices are firm for 30 days and subject to S&H CHGS 0 .00 change without notice after 30 days . Applicable taxes extra! Amount Due 1662 .01 -H- wrightsoft„ Load Short Form Job: Date: Jul 25,2017 Entire House By: HOP Energy/DDLC Energy 410 Bank Si,New London,CT 06237 Phone:860-271-2020 License:303006 Project Information For: TIMOTHY FEATHERSTONE 2 PHEASANT RUN, OAKDALE, CT 06370 Phone: 860-772-7735 Design Information Htg Clg Infiltration Outside db(°F) 6 85 Method Simplified Inside db (°F) 68 70 Construction quality Average Design TD (°F) 62 15 Fireplaces 1 (Average) Daily range - M Inside humidity (%) 50 50 Moisture difference(gr/Ib) 45 43 HEATING EQUIPMENT COOLING EQUIPMENT Make Make Trade Trade Model Cond AHRI ref Coil AHRI ref Efficiency 80AFUE Efficiency 0 SEER Heating input 0 Btuh Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Low output baseboard 500 Btuh/ft Total cooling 0 Btuh Total low baseboard 130 ft Actual air flow 1715 cfm High output baseboard 700 Btuh/ft Air flow factor 0.054 cfm/Btuh Total high baseboard 93 ft Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.88 ROOM NAME Area Htg load Clg load Baseboard (ft) Clg AVF (ft2) (Btuh) (Btuh) Low High (cfm) WHOLE HOUSE 2000 64924 31834 130 93 1715 Entire House d 2000 64924 31834 130 93 1715 Other equip loads 0 0 Equip. @ 0.90 RSM 28651 Latent cooling 4315 TOTALS 2000 64924 32966 130 93 1715 Bold/italic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2017-Jul-27 18:34:50 4 , " wrightsoft" Right-Suite®Universal 2017 17.0.01 RSU20117 Page 1 AAM ...ieco\Documents\Wrightsoft HVACIFEATHERSTONE.rup Calc=MJ8 Front Door faces: N -H- wrightsoft' Loads for Multiple Orientations Job: Date: Jul 25,2017 Entire House By: HOP Energy/DDLC Energy 410 Bank St,New London,CT 06237 Phone:860-271-2020 License:303006 Project Information For: TIMOTHY FEATHERSTONE 2 PHEASANT RUN, OAKDALE, CT 06370 Phone: 860-772-7735 Design Conditions Location: Indoor: Heating Cooling New London(Bridgeport Dd), CT, US Indoor temperature(OF) 68 70 Elevation: 10 ft Design TD (°F) 62 15 Latitude: 41°N Relative humidity (%) 50 50 Outdoor:bulb(°F) Heating Cooling Moisture difference(gr/lb) 45.0 42,7 Dry 6 Infiltration: Daily range(°F) - 20 ( M ) Wet bulb(°F) - 72 Wind speed (mph) 15.0 7.5 Front Door North Northeast East Southeast South Southwest West Northwest Sensible Load (Btuh) 28651 35002 41612 38918 33778 42241 47072 38978 Latent Load (Btuh) 4315 4801 5320 5083 4666 5323 5736 5083 Total Load (Btuh) 32966 39804 46932 44001 38444 47564 52807 44062 Heating AVF (cfm) 1715 2097 2488 2322 2023 2531 2810 2326 Cooling AVF (cfm) 1715 2097 2488 2322 2023 2531 2810 2326 Building Orientation Cooling Load ientation Cooli1:3ng Lo 0 0 J 2) 30000 0 0 0 To 20000 0 I- 10001 0 N NE E SE S SW W NW Direction Front Door faces Current Orientation: Front Door faces North Highest Cooling Load: Front Door faces West Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsoft Right-Suites Universal 2017 17.0.01 RSU20117 2017-Jul-27 18:34:50 Page 1 C. ...ieco\Documents\Wrightsoft HVAC\FEATHERSTONE.rup Calc=MJ8 Front Door faces: N d A= 1 I I 1 wrightsoft Building Analysis Job: Date: Jul 25,2017 Entire House By: HOP Energy/DDLC Energy 410 Bank St,New London,CT 06237 Phone:860-271-2020 License:303006 Pro'ect Information For: TIMOTHY FEATHERSTONE 2 PHEASANT RUN, OAKDALE, CT 06370 Phone: 860-772-7735 Design Conditions Location: Indoor: Heating Cooling New London(Bridgeport Dd), CT, US Indoor temperature(°F) 68 70 Elevation: 10 ft Design TD (°F) 62 15 Latitude: 41°N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 45.0 42.7 Dry bulb(°F) 6 85 Infiltration: Daily range(°F) - 20 ( M ) Method Simplified Wet bulb(°F) - 72 Constructionp uality Average Wind speed (mph) 15.0 7.5 Fireplaces 1 (Average) Heatin. Component Btuh/ft2 Btuh % of load Walls 6.0 10567 16.3 Glazing 35.3 6361 9.8 Doors 37.2 2344 3.6 Ceilings 4.3 8680 13.4 _` Floors 6.9 13742 21.2 ,,r>,: Infiltration 4.1 8272 12.7 Ducts 14959 23.0 -- Piping 0 0 Humidification 0 0 �� Ventilation 0 0 Adjustments 0 Total 64924 100.0 Coo lan. Component Btuh/ft2 Btuh % of load Walls 2.3 4107 12.9 wT�< Glazing 19.3 3476 10.9 Doors 15.9 1002 3.1 " Ceilings 3.5 7000 22.0 ° . =, - ° Floors 1.7 3325 10.4 Infiltration 0.4 880 2.8 ` Ducts 11125 34.9 Ventilation 0 0 Internal gains 920 2.9 y Blower 0 , Adjustments 0 ' Total 31834 100.0 "M° Fl a Latent Cooling Load=4315 Btuh Overall U-value= 0.173 Btuh/ft2-°F Data entries checked. Bold/italic values have been manually overridden 2017-Jul-2718:34:51wrightsoft Right-Suite®Universal 2017 17.0.01 RSU20117 .0 ...iecolDocuments\Wrightsoft HVACtFEATHERSTONE.rup Calc=MJ8 Front Door faces: N Page 1 -H- wrightsoftA Component Constructions Job: Date: Jul 25,2017 Entire House By: HOP Energy/DDLC Energy 410 Bank St,New London,CT 06237 Phone:860-271-2020 License:303006 Project Information For: TIMOTHY FEATHERSTONE 2 PHEASANT RUN, OAKDALE, CT 06370 Phone: 860-772-7735 Design Conditions Location: Indoor: Heating Cooling New London (Bridgeport Dd), CT, US Indoor temperature(°F) 68 70 Elevation: 10 ft Design TD (°F) 62 15 Latitude: 41°N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference(grub) 45.0 42.7 Dry bulb(°F) 6 85 Infiltration: Daily range(°F) - 20 ( M ) Method Simplified Wet bulb(°F) - 72 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 1 (Average) Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain fe Btuh/112-"F ft'-7/Btuh Btuh4t' Btuh Bluh/ft' Btuh Walls 12B-Osw:Frm wall,vnl ext,3/8"wood shth,r-11 cav ins,1/2" n 1757 0.097 11.0 6.01 10567 2.34 4107 gypsum board int fnsh,2"x4"wood frm, 16"o.c.stud Partitions (none) Windows 1D-c2ow:2 glazing,clr outr,air gas,wd frm mat,clr innr, 1/4"gap, n 180 0.570 0 35.3 6361 19.3 3476 1/8"thk:6.67 ft head ht Doors 11JO:Door,mtl fbrgl type n 63 0.600 6.3 37.2 2344 15.9 1002 Ceilings 16B-13ad:Attic ceiling,asphalt shingles roof mat,r-13 cell ins, 1/2" 2000 0.070 13.0 4,34 8680 3.50 7000 gypsum board int fnsh Floors 19A-Obswp:Fir floor,frm flr,6"thkns,hrd wd flr fnsh,tight bsmt our 2000 0.295 0 6.87 13742 1.66 3325 P III wrightsoft' Right-Suite®Universal 2017 17.0.01 RSU20117 2017-Jul 27 18:34:51 Page 1 ASC ...iecolDocuments\Wrightsoft NVAC\FEATHERSTONE.rup Calc=MJ8 Front Door faces: N - - wrightsoft, Component Constructions Job: WHOLE HOUSE Date: Jul 25,2017 By: HOP Energy/DDLC Energy 410 Bank St,New London,CT 06237 Phone:880-271-2020 License:303006 Project Information For: TIMOTHY FEATHERSTONE 2 PHEASANT RUN, OAKDALE, CT 06370 Phone: 860-772-7735 Design Conditions Location: Indoor: Heating Cooling New London (Bridgeport Dd), CT, US Indoor temperature(°F) 68 70 Elevation: 10 ft Design TD (°F) 62 15 Latitude: 41°N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 45.0 42.7 Dry bulb(°F) 6 85 Infiltration: Daily range °F) - 20 M Wet bulb(°F) - 72 ( ) Method Simplified Wind peed(mph) 15 0 7 5 Construction quality Average Fireplaces 1 (Average) Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain ft' Btuh/f-"F ft'-°F/Btuh Btuh/ft° Btuh Btuh/ft' Btuh Walls 12B-Osw:Frm wall,vnl ext,3/8"wood shth,r-11 cav ins, 1/2" n 1757 0.097 11.0 6.01 10567 2.34 4107 gypsum board int fnsh,2"x4"wood frm, 16"o.c.stud Partitions (none) Windows 1D-clow:2 glazing,clr outr,air gas,wd frm mat,clr innr, 1/4"gap, n 180 0.570 0 35.3 6361 19.3 3476 118"thk;6.67 ft head ht Doors 11JO:Door,mtl fbrgl type n 63 0.600 6.3 37.2 2344 15.9 1002 Ceilings 16B-13ad:Attic ceiling,asphalt shingles roof mat,r-13 cell ins, 1/2" 2000 0.070 13.0 4.34 8680 3.50 7000 gypsum board int fnsh Floors 19A-Obswp:Fir floor,frm flr,6"thkns,hrd wd flr fnsh,tight bsmt ovr 2000 0.295 0 6.87 13742 1.66 3325 +°�,. Ai- WCIC�l1tS0ft` Right-Suite®Universal 2017 17.0,01 RSU20117 2017-Jul-27 18:34:51 '�{.A ...ieco\DocumentslWrightsoft HVAC1FEATHERSTONE.rup Calc=MJ8 Front Door faces: N Page 2 -H- wrightsoft, Project Summary Job. Entire House Date: Jul 25,2017 By: HOP Energy/DDLC Energy 410 Bank St,New London,CT 06237 Phone:860-271-2020 License:303006 Pro'ect Information For: TIMOTHY FEATHERSTONE 2 PHEASANT RUN, OAKDALE, CT 06370 Phone: 860-772-7735 Notes: Desi• n Information Weather: New London (Bridgeport Dd), CT, US Winter Design Conditions Summer Design Conditions Outside db 6 °F Outside db 85 °F Inside db 68 °F Inside db 70 °F Design TD 62 °F Design TD 15 °F Daily range M Relative humidity 50 % Moisture difference 43 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 49965 Btuh Structure 20710 Btuh Ducts 14959 Btuh Ducts 11125 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower Pi in 0 Btuh Equipment load 64924 Btuh Use manufacturer's data n Rate/swing multiplier 0.90 Infiltration Equipment sensible load 28651 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 1 (Average) Structure 2347 Btuh Ducts 1968 Btuh Heating Cool i ng Central vent (0 cfm) 0 Btuh Area (ft2) 2000 2000 Equipment latent load 4315 Btuh Volume(ft') 16000 16000 Air changes/hour 0.45 0.20 Equipment total load 32966 Btuh Equiv.AVF (cfm) 121 53 Req. total capacity at 0.70 SHR 3.4 ton Heating Equipment Summary Cooling Equipment Summary Make Make Trade Trade Model Gond AHRI ref Coil AHRI ref Efficiency 80AFUE Efficiency 0 SEER Heating input 0 Btuh Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Low output baseboard 500 Btuh/ft Total cooling 0 Btuh Total low baseboard 130 ft Actual air flow 1715 cfm High output baseboard 700 Btuh/ft Air flow factor 0.054 cfm/Btuh Total high baseboard 93 ft Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.88 Bold/italic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. ...... vvrt htsoft Right-Suitee Universal 2017 17.0.01 RSU20117 2017-Jul-27 18:34:51 /ICG . ...ieco\Documents\Wrightsoft HVAC\FEATHERSTONE.rup Calc=MJ8 Front Door faces: N Page 1 wrightsoft AED Assessment Job: Entire House Date: Jul 25,2017 By: HOP Energy/DDLC Energy 410 Bank St,New London,CT 06237 Phone:860-271-2020 License:303006 Project Information For: TIMOTHY FEATHERSTONE 2 PHEASANT RUN, OAKDALE, CT 06370 Phone: 860-772-7735 Design Conditions Location: Indoor: Heating Cooling New London (Bridgeport Dd), CT, US Indoor temperature(°F) 68 70 Elevation: 10 ft Design TD (°F) 62 15 Latitude: 41°N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 45.0 42.7 Dry bulb(°F) 6 85 Infiltration: Daily range(°F) - 20 ( M ) Wet bulb(°F) - 72 Wind speed(mph) 15.0 7.5 Test for Adequate Exposure Diversity Hourly Glazing Load 5,500 5,000 4,500 4,000 co 3,500 33,000 \\\\ !J 22,500 2,000-- 1,500 1,000 - 500 0 I I ! ----i --- -F— I I { 8 9 10 11 12 13 14 15 16 17 18 19 20 Hour of Day .,-Ho0Y Average AED limit Maximum hourly glazing load exceeds average by 21.1%. House has adequate exposure diversity (AED), based on AED limit of 30%. AED excursion: 0 Btuh Bold/italic values have been manually overridden Ill wrightsoft RightSuitee Universal 2017 17.0.01 RSU20117 2017-Jul-27 18:34:51 ACG I\ ...ieco\Documents1Wrightsoft HVACIFEATHERSTONE.rup Calc=MJ8 Front Door faces: N Page 1 1 EP wrightsoft° Right-1®Worksheet Job: Entire House Date: Jul 25,2017 HOP Energy/DDLC Energy By: 410 Bank St,New London,CT 06237 Phone:860-271-2020 License:303006 1 Room name 2 Exposed wall Entire House WHOLE HOUSE 3 Room height 180.0 ft 180.0 ft 4 Room dimensions 8.0 ft d 8.0 ft heat/cool 5 Room area 40.0 x 50.0 ft 2000.0 ft2000.0 ft' Ty Construction U-value Or number (Btuh/ftp°F) (Btuh/ftl orTM rea perimeter (ft) Load orrea (ftp Load perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 +W 12B-0sw 0.097 n 6.01 2.34 2000 1757 10567 4107 2000 1757 10567 4107 I---G 1D-c2ow 0.570 n 35.34 19.31 180 0 6361 3476 180 0 6361 3476 III D 11.10 0.600 n 37.20 15.90 63 63 2344 1002 63 63 2344 1002 C 16B-138d 0.070 - 4.34 3.50 2000 2000 8680 7000 2000 2000 8680 7000 11 F 19A-Obswp 0.295 - 6.87 1.66 2000 2000 13742 3325 2000 2000 13742 3325 6 c)AED excursion 0 0 Envelope loss/gain 41693 18910 41693 18910 12 a) Infiltration b) Room ventilation 8272 880 8272 880 0 0 0 0 13 Internal gains: Occupants @ 230 4 Appliances/other 920 920 0 Subtotal(lines 6 to 13) 49965 20710 49965 20710 Less external load Less transfer 0 o 0 0 Redistribution 0 0 0 0 0 0 0 0 14 Subtotal 15 Duct loads 49965 20710 49965 20710 30% 54% 14959 11125 30% 54% 14959 11125 Total room load LowjHigh Baseboard/Cool Air 64924 31834 64924 31834 130 93 1715 130 93 1715 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. Wrightsoft- Right-Suite®Universal 2017 17.0.01 RSU20117 2017-Jul-27 19:34:51 Page 1 CC?, ...ieco\Documents\Wrightsoft HVAC\FEATHERSTONE.rup Calc=MJ8 Front Door faces: N ACC?,